MIB Viewer

IBM-AS400-RWS-MIB

24 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.2Nodeibm
1.3.6.1.4.1.2.6NodeibmProd
1.3.6.1.4.1.2.6.11NodeibmAs400Agent
1.3.6.1.4.1.2.6.11.1NodeibmAs400Rws
1.3.6.1.4.1.2.6.11.1.1TablerwsTablenot-accessiblemandatoryTable of AS/400 remote workstation (RWS) controllers.
1.3.6.1.4.1.2.6.11.1.1.1RowrwsEntrynot-accessiblemandatoryAn entry for each RWS controller. Table is indexed by rwsCtlName.
1.3.6.1.4.1.2.6.11.1.1.1.1ColumnrwsCtlNameread-onlymandatoryRWS controller description name.
1.3.6.1.4.1.2.6.11.1.1.1.2ColumnrwsOperStateread-writemandatoryOperational state of the RWS controller description.
1.3.6.1.4.1.2.6.11.1.1.1.3ColumnrwsAppcDevNameread-onlymandatoryName of the APPC device description associated with the RWS controller.
1.3.6.1.4.1.2.6.11.1.1.1.4ColumnrwsAppcDevStateread-writemandatoryOperational state of the associated APPC device.
1.3.6.1.4.1.2.6.11.1.1.1.5ColumnrwsAppcCtlNameread-onlymandatoryName of the APPC controller associated with the RWS controller. The associated APPN MIB instance of ibmappnNodeLsState gives its operational state.
1.3.6.1.4.1.2.6.11.1.1.1.6ColumnrwsCpNameread-onlymandatoryFully-qualified control point name of the remote control unit. Format is NETID.CPNAME.
1.3.6.1.4.1.2.6.11.1.1.1.7ColumnrwsTyperead-onlymandatoryMachine type of the RWS controller.
1.3.6.1.4.1.2.6.11.1.1.1.8ColumnrwsModelread-onlymandatoryModel number of the RWS controller.
1.3.6.1.4.1.2.6.11.1.1.1.9ColumnrwsSerialread-onlymandatorySerial number value in format xx-yyyyyyy, from the customer setup (CSU) field. In general, xx is the Plant of Manufacture, and yyyyyyy is the serial number. Ho…
1.3.6.1.4.1.2.6.11.1.1.1.10ColumnrwsReleaseread-onlymandatoryMicrocode release, modification and patch level. For a 5494, the format is rrrrmmpp, For a 5394 BB, the format is rrpp, where r=release digit, m=modification d…
1.3.6.1.4.1.2.6.11.1.2TablerwsDevTablenot-accessiblemandatoryTable of nonprogrammable devices attached to RWS controllers.
1.3.6.1.4.1.2.6.11.1.2.1RowrwsDevEntrynot-accessiblemandatoryAn entry for each nonprogrammable device attached to an RWS controller. Table is indexed by rwsCtlName and rwsDevName.
1.3.6.1.4.1.2.6.11.1.2.1.1ColumnrwsDevCtlNameread-onlymandatoryController name associated with device.
1.3.6.1.4.1.2.6.11.1.2.1.2ColumnrwsDevNameread-onlymandatoryDevice name.
1.3.6.1.4.1.2.6.11.1.2.1.3ColumnrwsDevOperStateread-writemandatoryOperational state of device.
1.3.6.1.4.1.2.6.11.1.2.1.4ColumnrwsDevSerialread-onlymandatorySerial number value in format xx-yyyyyyy, reported by the RWS control unit for the device. In general, xx is the Plant of Manufacture, and yyyyyyy is the seria…
1.3.6.1.4.1.2.6.11.1.99NoderwsGeneralInfo
1.3.6.1.4.1.2.6.11.1.99.1ScalarrwsNumCtlsread-onlymandatoryNumber of RWS controllers (rows in rwsTable).