IBM-AS400-RWS-MIB
24 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2 | Nodeibm | |||
| 1.3.6.1.4.1.2.6 | NodeibmProd | |||
| 1.3.6.1.4.1.2.6.11 | NodeibmAs400Agent | |||
| 1.3.6.1.4.1.2.6.11.1 | NodeibmAs400Rws | |||
| 1.3.6.1.4.1.2.6.11.1.1 | TablerwsTable | not-accessible | mandatory | Table of AS/400 remote workstation (RWS) controllers. |
| 1.3.6.1.4.1.2.6.11.1.1.1 | RowrwsEntry | not-accessible | mandatory | An entry for each RWS controller. Table is indexed by rwsCtlName. |
| 1.3.6.1.4.1.2.6.11.1.1.1.1 | ColumnrwsCtlName | read-only | mandatory | RWS controller description name. |
| 1.3.6.1.4.1.2.6.11.1.1.1.2 | ColumnrwsOperState | read-write | mandatory | Operational state of the RWS controller description. |
| 1.3.6.1.4.1.2.6.11.1.1.1.3 | ColumnrwsAppcDevName | read-only | mandatory | Name of the APPC device description associated with the RWS controller. |
| 1.3.6.1.4.1.2.6.11.1.1.1.4 | ColumnrwsAppcDevState | read-write | mandatory | Operational state of the associated APPC device. |
| 1.3.6.1.4.1.2.6.11.1.1.1.5 | ColumnrwsAppcCtlName | read-only | mandatory | Name of the APPC controller associated with the RWS controller. The associated APPN MIB instance of ibmappnNodeLsState gives its operational state. |
| 1.3.6.1.4.1.2.6.11.1.1.1.6 | ColumnrwsCpName | read-only | mandatory | Fully-qualified control point name of the remote control unit. Format is NETID.CPNAME. |
| 1.3.6.1.4.1.2.6.11.1.1.1.7 | ColumnrwsType | read-only | mandatory | Machine type of the RWS controller. |
| 1.3.6.1.4.1.2.6.11.1.1.1.8 | ColumnrwsModel | read-only | mandatory | Model number of the RWS controller. |
| 1.3.6.1.4.1.2.6.11.1.1.1.9 | ColumnrwsSerial | read-only | mandatory | Serial number value in format xx-yyyyyyy, from the customer setup (CSU) field. In general, xx is the Plant of Manufacture, and yyyyyyy is the serial number. Ho… |
| 1.3.6.1.4.1.2.6.11.1.1.1.10 | ColumnrwsRelease | read-only | mandatory | Microcode release, modification and patch level. For a 5494, the format is rrrrmmpp, For a 5394 BB, the format is rrpp, where r=release digit, m=modification d… |
| 1.3.6.1.4.1.2.6.11.1.2 | TablerwsDevTable | not-accessible | mandatory | Table of nonprogrammable devices attached to RWS controllers. |
| 1.3.6.1.4.1.2.6.11.1.2.1 | RowrwsDevEntry | not-accessible | mandatory | An entry for each nonprogrammable device attached to an RWS controller. Table is indexed by rwsCtlName and rwsDevName. |
| 1.3.6.1.4.1.2.6.11.1.2.1.1 | ColumnrwsDevCtlName | read-only | mandatory | Controller name associated with device. |
| 1.3.6.1.4.1.2.6.11.1.2.1.2 | ColumnrwsDevName | read-only | mandatory | Device name. |
| 1.3.6.1.4.1.2.6.11.1.2.1.3 | ColumnrwsDevOperState | read-write | mandatory | Operational state of device. |
| 1.3.6.1.4.1.2.6.11.1.2.1.4 | ColumnrwsDevSerial | read-only | mandatory | Serial number value in format xx-yyyyyyy, reported by the RWS control unit for the device. In general, xx is the Plant of Manufacture, and yyyyyyy is the seria… |
| 1.3.6.1.4.1.2.6.11.1.99 | NoderwsGeneralInfo | |||
| 1.3.6.1.4.1.2.6.11.1.99.1 | ScalarrwsNumCtls | read-only | mandatory | Number of RWS controllers (rows in rwsTable). |