IBM-SYSTEM-STORAGE-MIB
173 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2.6.159.3.1 | NodeibmStorageTrap | |||
| 1.3.6.1.4.1.2.6.159.3.1.201 | NodeibmStorageNoControllers | Informational: No controllers were found in this system. | ||
| 1.3.6.1.4.1.2.6.159.3.1.202 | NodeibmStorageControllerFail | Error: Commands not responding on the Controller. | ||
| 1.3.6.1.4.1.2.6.159.3.1.203 | NodeibmStorageDeadBattery | Error: The battery-backup cache device on a Controller needs a new battery. | ||
| 1.3.6.1.4.1.2.6.159.3.1.204 | NodeibmStorageDeadBatteryCache | Error: The battery-backup cache device on a Controller is defective | ||
| 1.3.6.1.4.1.2.6.159.3.1.205 | NodeibmStoragePollingFail | Error: Background polling commands not responding on a Controller | ||
| 1.3.6.1.4.1.2.6.159.3.1.206 | NodeibmStorageConfigFail | Error: Cannot read controller configuration. | ||
| 1.3.6.1.4.1.2.6.159.3.1.207 | NodeibmStorageControllerAdded | Informational: Controller has been added to the system. | ||
| 1.3.6.1.4.1.2.6.159.3.1.208 | NodeibmStorageControllerReplaced | Informational: Controller has been replaced in the system. | ||
| 1.3.6.1.4.1.2.6.159.3.1.209 | NodeibmStorageControllerFailover | Informational: Controller failover detected. Passive controller is now active. | ||
| 1.3.6.1.4.1.2.6.159.3.1.210 | NodeibmStorageControllerVersionMismatch | Warning: A Controller version mismatch detected. The BIOS, Firmware, and Driver are not a matched set and are not compatible. | ||
| 1.3.6.1.4.1.2.6.159.3.1.211 | NodeibmStorageControllerBatteryOvertemp | Warning: Controller battery has exceeded normal operating temperature. | ||
| 1.3.6.1.4.1.2.6.159.3.1.215 | NodeibmStorageControllerBadStripes | Warning: One or more logical drives contain a bad stripe. | ||
| 1.3.6.1.4.1.2.6.159.3.1.216 | NodeibmStorageControllerBatteryTempNormal | Informational: Controller battery operating temperature is normal. | ||
| 1.3.6.1.4.1.2.6.159.3.1.217 | NodeibmStorageControllerStatusChange | A Controller has changed status | ||
| 1.3.6.1.4.1.2.6.159.3.1.301 | NodeibmStorageLogicalDriveCritical | Warning: A Logical Drive is Critical | ||
| 1.3.6.1.4.1.2.6.159.3.1.302 | NodeibmStorageLogicalDriveBlocked | Error: A Logical Drive is Blocked. | ||
| 1.3.6.1.4.1.2.6.159.3.1.303 | NodeibmStorageLogicalDriveOffLine | Error: Logical Drive is Offline | ||
| 1.3.6.1.4.1.2.6.159.3.1.304 | NodeibmStorageRebuildDetected | Informational: Rebuilding Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.305 | NodeibmStorageRebuildComplete | Informational: Rebuild complete of Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.306 | NodeibmStorageRebuildFail | Error: Rebuild failed of Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.307 | NodeibmStorageSyncDetected | Informational: Synchronizing Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.308 | NodeibmStorageSyncComplete | Informational: Synchronization complete of Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.309 | NodeibmStorageSyncFail | Error: Synchronization failed of Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.310 | NodeibmStorageMigrationDetected | Informational: Migrating Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.311 | NodeibmStorageMigrationComplete | Informational: Migration complete on Logical Drive %d of Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.3.1.312 | NodeibmStorageMigrationFail | Error: Migration failed on Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.313 | NodeibmStorageCompressionDetected | Informational: Compressing Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.314 | NodeibmStorageCompressionComplete | Informational: Compression complete of Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.315 | NodeibmStoragecompressionFail | Error: Compression failed of Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.316 | NodeibmStorageDecompressionDetected | Informational: Decompressing Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.317 | NodeibmStorageDecompressionComplete | Informational: Decompression complete of Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.318 | NodeibmStorageDecompressionFail | Error: Decompression failed of Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.319 | NodeibmStorageFlashCopyDetected | Informational: FlashCopying Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.320 | NodeibmStorageFlashCopyComplete | Informational: FlashCopy complete on Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.321 | NodeibmStorageFlashCopyFail | Error: FlashCopy failed on Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.322 | NodeibmStorageArrayRebuildDetected | Informational: Rebuilding Array. | ||
| 1.3.6.1.4.1.2.6.159.3.1.323 | NodeibmStorageArrayRebuildComplete | Informational: Rebuild complete of Array. | ||
| 1.3.6.1.4.1.2.6.159.3.1.324 | NodeibmStorageArrayRebuildFail | Error: Rebuild failed on Array. | ||
| 1.3.6.1.4.1.2.6.159.3.1.325 | NodeibmStorageArraySyncDetected | Informational: Synchronizing Array. | ||
| 1.3.6.1.4.1.2.6.159.3.1.326 | NodeibmStorageArraySyncComplete | Informational: Synchronization complete on Array. | ||
| 1.3.6.1.4.1.2.6.159.3.1.327 | NodeibmStorageArraySyncFail | Error: Synchronization failed on Array. | ||
| 1.3.6.1.4.1.2.6.159.3.1.328 | NodeibmStorageArrayFlashCopyDetected | Informational: FlashCopying Array. | ||
| 1.3.6.1.4.1.2.6.159.3.1.329 | NodeibmStorageArrayFlashCopyComplete | Informational: FlashCopy complete on Array. | ||
| 1.3.6.1.4.1.2.6.159.3.1.330 | NodeibmStorageArrayFlashCopyFail | Error: FlashCopy failed on Array. | ||
| 1.3.6.1.4.1.2.6.159.3.1.331 | NodeibmStorageLogicalDriveUnblocked | Informational: Logical Drive is unblocked. | ||
| 1.3.6.1.4.1.2.6.159.3.1.332 | NodeibmStorageCompactionDetected | Informational: Compacting Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.333 | NodeibmStorageCompactionComplete | Informational: Compaction complete on Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.334 | NodeibmStorageCompactionFail | Error: Compaction failed on Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.335 | NodeibmStorageExpansionDetected | Informational: Expanding Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.336 | NodeibmStorageExpansionComplete | Informational: Expansion complete on Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.337 | NodeibmStorageExpansionFail | Error: Expansion failed on Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.338 | NodeibmStorageLogicalDriveCriticalPeriodic | Warning: Periodic scan found 1 or more critical logical drives. | ||
| 1.3.6.1.4.1.2.6.159.3.1.339 | NodeibmStorageCopyBackDetected | Informational: Copy back in progress on Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.340 | NodeibmStorageCopyBackComplete | Informational: Copy back complete on Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.341 | NodeibmStorageCopyBackFail | Error: Copy back failed on Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.342 | NodeibmStorageInitDetected | Informational: Initialization in progress on Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.343 | NodeibmStorageInitComplete | Informational: Initialization complete on Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.344 | NodeibmStorageInitFail | Error: Initialization failed on Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.345 | NodeibmStorageLogicalDriveOK | Informational: Logical Drive is normal. | ||
| 1.3.6.1.4.1.2.6.159.3.1.346 | NodeibmStorageLogicalDriveAdded | Informational: Added Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.347 | NodeibmStorageLogicalDriveRemoved | Informational: Removed Logical Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.348 | NodeibmStorageArrayFlashCopyStopped | Array Flash Copy has stopped | ||
| 1.3.6.1.4.1.2.6.159.3.1.349 | NodeibmStorageArrayRebuildStopped | Array Rebuild has stopped | ||
| 1.3.6.1.4.1.2.6.159.3.1.350 | NodeibmStorageArrayStatusChange | An Array has had a status change | ||
| 1.3.6.1.4.1.2.6.159.3.1.351 | NodeibmStorageArraySyncStopped | Array Sync has stopped | ||
| 1.3.6.1.4.1.2.6.159.3.1.352 | NodeibmStorageCompactionStopped | Compaction has stopped | ||
| 1.3.6.1.4.1.2.6.159.3.1.353 | NodeibmStorageCompressionStopped | Compression has stopped | ||
| 1.3.6.1.4.1.2.6.159.3.1.354 | NodeibmStorageCopybackStopped | Copyback has stopped | ||
| 1.3.6.1.4.1.2.6.159.3.1.355 | NodeibmStorageDecompressionStopped | Decompression has stopped | ||
| 1.3.6.1.4.1.2.6.159.3.1.356 | NodeibmStorageExpansionStopped | Expansion has stopped | ||
| 1.3.6.1.4.1.2.6.159.3.1.357 | NodeibmStorageFlashCopyStopped | FlashCopy has stopped | ||
| 1.3.6.1.4.1.2.6.159.3.1.358 | NodeibmStorageInitStopped | Initialization has stopped | ||
| 1.3.6.1.4.1.2.6.159.3.1.359 | NodeibmStorageLogicalDriveStatusChange | A Logical Drive has had a status change | ||
| 1.3.6.1.4.1.2.6.159.3.1.360 | NodeibmStorageMigrationStopped | Migration has stopped | ||
| 1.3.6.1.4.1.2.6.159.3.1.361 | NodeibmStorageRebuildStopped | A Rebuild has stopped | ||
| 1.3.6.1.4.1.2.6.159.3.1.362 | NodeibmStorageSyncStopped | A Synchronization has stopped | ||
| 1.3.6.1.4.1.2.6.159.3.1.401 | NodeibmStorageDefunctDrive | Error: Defunct drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.402 | NodeibmStoragePfaDrive | Warning: A Drive reports a PFA. | ||
| 1.3.6.1.4.1.2.6.159.3.1.403 | NodeibmStorageDefunctReplaced | Informational: A drive is set to Hot-Spare. | ||
| 1.3.6.1.4.1.2.6.159.3.1.404 | NodeibmStorageDefunctDriveFru | Error: A Drive reports Defunct stauts. | ||
| 1.3.6.1.4.1.2.6.159.3.1.405 | NodeibmStoragePfaDriveFru | Warning: A Drive reports a PFA. | ||
| 1.3.6.1.4.1.2.6.159.3.1.406 | NodeibmStorageUnsupportedDrive | Warning: Unsupported physical drive found. | ||
| 1.3.6.1.4.1.2.6.159.3.1.407 | NodeibmStorageDriveAdded | Informational: A Drive has been added. | ||
| 1.3.6.1.4.1.2.6.159.3.1.408 | NodeibmStorageDriveRemoved | Informational: A Drive has been removed. | ||
| 1.3.6.1.4.1.2.6.159.3.1.409 | NodeibmStorageDriveClearDetected | Informational: A Drive clear is in progress. | ||
| 1.3.6.1.4.1.2.6.159.3.1.410 | NodeibmStorageDriveClearComplete | Informational: Clear complete on Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.411 | NodeibmStorageDriveClearFail | Error: Clear failed on Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.412 | NodeibmStorageDriveSyncDetected | Informational: Synchronization in progress on Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.413 | NodeibmStorageDriveSyncComplete | Informational: Synchronization complete on Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.414 | NodeibmStorageDriveSyncFail | Error: Synchronization failed on Drive. | ||
| 1.3.6.1.4.1.2.6.159.3.1.415 | NodeibmStorageDriveVerifyDetected | Informational: A Drive Verify is in progress. | ||
| 1.3.6.1.4.1.2.6.159.3.1.416 | NodeibmStorageDriveVerifyComplete | Informational: Drive Verify complete. | ||
| 1.3.6.1.4.1.2.6.159.3.1.417 | NodeibmStorageDriveVerifyFail | Error: Drive Verify failed. | ||
| 1.3.6.1.4.1.2.6.159.3.1.418 | NodeibmStorageDriveClearStopped | Drive Clear has stopped | ||
| 1.3.6.1.4.1.2.6.159.3.1.419 | NodeibmStorageDriveSecureEraseStopped | A Drive Secure Erase has stopped | ||
| 1.3.6.1.4.1.2.6.159.3.1.420 | NodeibmStorageDriveStatusChange | A Drive reports a status change | ||
| 1.3.6.1.4.1.2.6.159.3.1.421 | NodeibmStorageDriveSyncStopped | A Drive Synchronization has stopped | ||
| 1.3.6.1.4.1.2.6.159.3.1.422 | NodeibmStorageDriveVerifyStopped | A Drive Verify has stopped | ||
| 1.3.6.1.4.1.2.6.159.3.1.423 | NodeibmStorageSpareCreated | A Spare Drive has been created | ||
| 1.3.6.1.4.1.2.6.159.3.1.424 | NodeibmStorageSpareDeleted | A Spare Drive has been deleted | ||
| 1.3.6.1.4.1.2.6.159.3.1.501 | NodeibmStorageEnclosureOK | Informational: Enclosure device responding. | ||
| 1.3.6.1.4.1.2.6.159.3.1.502 | NodeibmStorageEnclosureFail | Error: Enclosure device not responding. | ||
| 1.3.6.1.4.1.2.6.159.3.1.503 | NodeibmStorageFanOk | Informational: Enclosure fan is now operational. | ||
| 1.3.6.1.4.1.2.6.159.3.1.504 | NodeibmStorageFanFail | Error: Enclosure fan is malfunctioning. | ||
| 1.3.6.1.4.1.2.6.159.3.1.505 | NodeibmStorageFanInstalled | Informational: Enclosure fan has been installed. | ||
| 1.3.6.1.4.1.2.6.159.3.1.506 | NodeibmStorageFanRemoved | Warning: Enclosure fan has been removed. | ||
| 1.3.6.1.4.1.2.6.159.3.1.507 | NodeibmStorageTempOk | Error: Enclosure temperature is in normal range. | ||
| 1.3.6.1.4.1.2.6.159.3.1.508 | NodeibmStorageTempFail | Error: Enclosure temperature is out of normal range on Controller. | ||
| 1.3.6.1.4.1.2.6.159.3.1.509 | NodeibmStoragePowerSupplyOk | Informational: Enclosure power supply is now operational. | ||
| 1.3.6.1.4.1.2.6.159.3.1.510 | NodeibmStoragePowerSupplyFail | Error: Enclosure power supply is malfunctioning. | ||
| 1.3.6.1.4.1.2.6.159.3.1.511 | NodeibmStoragePowerSupplyInstalled | Informational: Enclosure power supply has been installed. | ||
| 1.3.6.1.4.1.2.6.159.3.1.512 | NodeibmStoragePowerSupplyRemoved | Warning: Enclosure power supply has been removed. | ||
| 1.3.6.1.4.1.2.6.159.3.1.601 | NodeibmStorageTestTrap | Informational: This is a test trap. | ||
| 1.3.6.1.4.1.2.6.159.3.1.1000 | NodeibmStorageLsiPDFail | A Drive has failed | ||
| 1.3.6.1.4.1.2.6.159.3.1.1003 | NodeibmStorageLsiPDPartOfLDFail | Part of a Logical Drive has failed | ||
| 1.3.6.1.4.1.2.6.159.3.1.1004 | NodeibmStorageLsiPDPartOfLDAdd | Drive added to Logical Drive | ||
| 1.3.6.1.4.1.2.6.159.3.1.1005 | NodeibmStorageLsiHSPartOfLD | Hot Spare has been added | ||
| 1.3.6.1.4.1.2.6.159.3.1.1007 | NodeibmStorageLsiHSFail | A Hot Spare has failed | ||
| 1.3.6.1.4.1.2.6.159.3.1.1008 | NodeibmStorageLsiPDHS | Physial Drive has been made a Hot Spare | ||
| 1.3.6.1.4.1.2.6.159.3.1.1009 | NodeibmStorageLsiLDOffline | Logical Drive is off-line | ||
| 1.3.6.1.4.1.2.6.159.3.1.1011 | NodeibmStorageLsiLDDegraded | Logical Drive is in degraded state | ||
| 1.3.6.1.4.1.2.6.159.3.1.1012 | NodeibmStorageLsiLDOptimal | Logical Drive is optimal | ||
| 1.3.6.1.4.1.2.6.159.3.1.1013 | NodeibmStorageLsiSMARTError | A Drive is reporting a PFA | ||
| 1.3.6.1.4.1.2.6.159.3.1.1014 | NodeibmStorageLsiStoragePoolStatus | Indicates a status change or status of the storage pool | ||
| 1.3.6.1.4.1.2.6.159.3.1.1015 | NodeibmStorageLsiRbldStart | Volume rebuild has started | ||
| 1.3.6.1.4.1.2.6.159.3.1.1016 | NodeibmStorageLsiRbldComplete | Volume rebuild complete | ||
| 1.3.6.1.4.1.2.6.159.3.1.1017 | NodeibmStorageLsiRbldFail | Volume rebuild has failed | ||
| 1.3.6.1.4.1.2.6.159.3.1.1020 | NodeibmStorageLsiStorageVolumeStatus | Indicates a status change or status of the storage volume | ||
| 1.3.6.1.4.1.2.6.159.3.1.1031 | NodeibmStorageLsiControllerStatus | Indicates a status change or status of the controller | ||
| 1.3.6.1.4.1.2.6.159.3.1.1032 | NodeibmStorageLsiDiskDriveStatus | Indicates a status change or status of the disk drive | ||
| 1.3.6.1.4.1.2.6.159.3.2 | NodeibmStorageTrapInfo | |||
| 1.3.6.1.4.1.2.6.159.3.2.1 | ScalaribmStorageTrapProviderName | not-accessible | mandatory | The CIM Provider Name |
| 1.3.6.1.4.1.2.6.159.3.2.2 | ScalaribmStorageTrapEventID | not-accessible | mandatory | A unique EventID that identifies the item reporting the issue |
| 1.3.6.1.4.1.2.6.159.3.2.3 | ScalaribmStorageTrapPerceivedSeverity | not-accessible | mandatory | Severity of the event 0=Normal / OK 1=Warning 2=Critical |
| 1.3.6.1.4.1.2.6.159.3.2.4 | ScalaribmStorageDescription | not-accessible | mandatory | The event message |
| 1.3.6.1.4.1.2.6.159.3.2.5 | ScalaribmStorageTrapEventTime | not-accessible | mandatory | Time that the event occured |
| 1.3.6.1.4.1.2.6.159.3.3 | TableibmStorageControllerTable | not-accessible | mandatory | This table describes the asset information of the Storage Controller objects |
| 1.3.6.1.4.1.2.6.159.3.3.1 | RowibmStorageControllerEntry | not-accessible | mandatory | Each entry represents a unique Storage Controller in the system |
| 1.3.6.1.4.1.2.6.159.3.3.1.1 | ColumnibmStorageControllerKeyIndex | read-only | mandatory | The index used by this table |
| 1.3.6.1.4.1.2.6.159.3.3.1.2 | ColumnibmStorageControllerModel | read-only | mandatory | The model of the controller |
| 1.3.6.1.4.1.2.6.159.3.3.1.3 | ColumnibmStorageControllerSerialNumber | read-only | mandatory | The serial number of the controller |
| 1.3.6.1.4.1.2.6.159.3.4 | TableibmStorageDiskDriveTable | not-accessible | mandatory | This table describes the physical disk drives attached to the storage controller(s) |
| 1.3.6.1.4.1.2.6.159.3.4.0 | RowibmStorageDiskDriveTableUp | read-only | mandatory | Returns Agent Version if Storage DiskDrive data is available. |
| 1.3.6.1.4.1.2.6.159.3.4.1 | RowibmStorageDiskDriveEntry | not-accessible | mandatory | Each entry represents a single physcial disk drive in the system. |
| 1.3.6.1.4.1.2.6.159.3.4.1.1 | ColumnibmStorageDiskDriveKeyIndex | read-only | mandatory | The index used by this table |
| 1.3.6.1.4.1.2.6.159.3.4.1.2 | ColumnibmStorageDiskDriveDeviceID | read-only | mandatory | The DeviceID of the physical disk |
| 1.3.6.1.4.1.2.6.159.3.4.1.3 | ColumnibmStorageDiskDriveName | read-only | mandatory | A user friendly name assigned to the physical disk |
| 1.3.6.1.4.1.2.6.159.3.4.1.4 | ColumnibmStorageDiskDriveElementName | read-only | mandatory | A user friendly name assigned to the physical disk |
| 1.3.6.1.4.1.2.6.159.3.4.1.5 | ColumnibmStorageDiskDriveUnitsUsed | read-only | mandatory | Number of Units used on the physcial disk |
| 1.3.6.1.4.1.2.6.159.3.4.1.6 | ColumnibmStorageDiskDriveOperationalStatus | read-only | mandatory | The Operational Status of the physical disk. Possible values are: OK = Drive is online Error = Drive is not functional Stopped = Drive is disabled Stopping = D… |
| 1.3.6.1.4.1.2.6.159.3.5 | TableibmStorageStorageVolumeTable | not-accessible | mandatory | This table represents a storage volume which can consist of one or more physical disk drives |
| 1.3.6.1.4.1.2.6.159.3.5.0 | RowibmStorageStorageVolumeTableUp | read-only | mandatory | Returns Agent Version if Storage Volume data is available. |
| 1.3.6.1.4.1.2.6.159.3.5.1 | RowibmStorageStorageVolumeEntry | not-accessible | mandatory | Each entry defines a single storage volume |
| 1.3.6.1.4.1.2.6.159.3.5.1.1 | ColumnibmStorageStorageVolumeKeyIndex | read-only | mandatory | The index used by this table |
| 1.3.6.1.4.1.2.6.159.3.5.1.2 | ColumnibmStorageStorageVolumeDeviceID | read-only | mandatory | The DeviceID of the storage volume |
| 1.3.6.1.4.1.2.6.159.3.5.1.3 | ColumnibmStorageStorageVolumeName | read-only | mandatory | A user friendly name assigned to the storage volume |
| 1.3.6.1.4.1.2.6.159.3.5.1.4 | ColumnibmStorageStorageVolumeElementName | read-only | mandatory | A user friendly name assigned to the storage volume |
| 1.3.6.1.4.1.2.6.159.3.5.1.5 | ColumnibmStorageStorageVolumeBlockSize | read-only | mandatory | The block size used by the storage volume |
| 1.3.6.1.4.1.2.6.159.3.5.1.6 | ColumnibmStorageStorageVolumeConsumableBlocks | read-only | mandatory | The number of consumable blocks in the storage volume |
| 1.3.6.1.4.1.2.6.159.3.5.1.7 | ColumnibmStorageStorageVolumeDataRedundancy | read-only | mandatory | Number of complete copies of the data currently maintained |
| 1.3.6.1.4.1.2.6.159.3.5.1.8 | ColumnibmStorageStorageVolumeNoSinglePointOfFailure | read-only | mandatory | Indicates if there is no single point of failure |
| 1.3.6.1.4.1.2.6.159.3.5.1.9 | ColumnibmStorageStorageVolumeOperationalStatus | read-only | mandatory | Operations Status of the storage volume Possible values are: Degraded = A drive has failed, a rebuild is in process, or a spare drive is in use. Error = The vo… |
| 1.3.6.1.4.1.2.6.159.3.6 | TableibmStorageSoftwareIdentityTable | not-accessible | mandatory | The table describes the Firmware, BIOS, and driver information for physical components of the storage system. |
| 1.3.6.1.4.1.2.6.159.3.6.1 | RowibmStorageSoftwareIdentityEntry | not-accessible | mandatory | Each entry represents a unique software identity |
| 1.3.6.1.4.1.2.6.159.3.6.1.1 | ColumnibmStorageSoftwareIdentityKeyIndex | read-only | mandatory | The index used by this table |
| 1.3.6.1.4.1.2.6.159.3.6.1.2 | ColumnibmStorageSoftwareIdentityDescription | read-only | mandatory | A description of the software item |
| 1.3.6.1.4.1.2.6.159.3.6.1.3 | ColumnibmStorageSoftwareIdentityCaption | read-only | mandatory | A user friendly name for the software item |
| 1.3.6.1.4.1.2.6.159.3.6.1.4 | ColumnibmStorageSoftwareIdentityElementName | read-only | mandatory | A user friendly name for the software item |
| 1.3.6.1.4.1.2.6.159.3.6.1.5 | ColumnibmStorageSoftwareIdentityInstanceID | read-only | mandatory | An instanceID assigned to the software item |
| 1.3.6.1.4.1.2.6.159.3.6.1.6 | ColumnibmStorageSoftwareIdentityManufacturer | read-only | mandatory | The manufacturer of the software |
| 1.3.6.1.4.1.2.6.159.3.6.1.7 | ColumnibmStorageSoftwareIdentityVersionString | read-only | mandatory | The current version of the software item |
| 1.3.6.1.4.1.2.6.159.3.6.1.8 | ColumnibmStorageSoftwareIdentitySerialNumber | read-only | mandatory | The serial number of the device |