IBM2260-OPT-MIB
61 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC1155-SMI | Counter enterprises |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.449 | Nodecodex | |||
| 1.3.6.1.4.1.449.2 | NodecdxProductSpecific | |||
| 1.3.6.1.4.1.449.2.1 | Nodecdx6500 | |||
| 1.3.6.1.4.1.449.2.1.2 | Nodecdx6500Configuration | |||
| 1.3.6.1.4.1.449.2.1.2.1 | Nodecdx6500CfgProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.2.1.1 | Nodecdx6500PCTPortProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.2.1.1.20 | Tablecdx6500PPCTIBM2260PortTable | not-accessible | mandatory | A list of IBM2260 Port configuration entries. |
| 1.3.6.1.4.1.449.2.1.2.1.1.20.1 | Rowcdx6500PPCTIBM2260PortEntry | not-accessible | mandatory | An IBM2260 Configuration Table entry. Each entry contains the configuration parameters for a single IBM2260 port. |
| 1.3.6.1.4.1.449.2.1.2.1.1.20.1.1 | Columncdx6500IBM2260CfgPortNumber | read-only | mandatory | The port number corresponding to this port. |
| 1.3.6.1.4.1.449.2.1.2.1.1.20.1.2 | Columncdx6500IBM2260CfgPadType | read-only | mandatory | Indicates whether the port is functioning as a Terminal PAD (TPAD) or a Host PAD (HPAD). |
| 1.3.6.1.4.1.449.2.1.2.1.1.20.1.3 | Columncdx6500IBM2260CfgPortSpeed | read-only | mandatory | This is the speed of the port in bits per second, when using internal clocking. |
| 1.3.6.1.4.1.449.2.1.2.1.1.20.1.4 | Columncdx6500IBM2260CfgConnType | read-only | mandatory | Specify the control signal handshake required for a connection to be made to this port: simp - simple, no control signals required. simpa - CTS follows RTS, bu… |
| 1.3.6.1.4.1.449.2.1.2.1.1.20.1.5 | Columncdx6500IBM2260CfgNumDevice | read-only | mandatory | Specifies the number of IBM2260 stations on this line. |
| 1.3.6.1.4.1.449.2.1.2.1.1.20.1.6 | Columncdx6500IBM2260CfgServiceTimer | read-only | mandatory | The Service Timer specifies the interval of time in seconds between periodic servicing. Such servicing includes intervals between attempts to establish network… |
| 1.3.6.1.4.1.449.2.1.2.1.1.20.1.7 | Columncdx6500IBM2260CfgThreshCtr | read-only | mandatory | Indicates number of consecutive errors that can occur before a station is considered down. |
| 1.3.6.1.4.1.449.2.1.2.1.1.20.1.8 | Columncdx6500IBM2260CfgRespTimeout | read-only | mandatory | Specifies the amount of time in msec the PAD allows a terminal, printer or host to respond. As a result, the TPAD may re-transmit the previous message or abort… |
| 1.3.6.1.4.1.449.2.1.2.1.1.20.1.9 | Columncdx6500IBM2260CfgPortSubAddr | read-only | mandatory | Calls addressed to this node and with this subaddress will be routed to this port. |
| 1.3.6.1.4.1.449.2.1.2.1.1.20.1.10 | Columncdx6500IBM2260CfgPortOpt | read-only | mandatory | Select options on this IBM2260 port as follows: NONE - No option specified ORG - Originate calls from this port ACK - DSP End-to-End Acknowledgements are to be… |
| 1.3.6.1.4.1.449.2.1.2.1.1.20.1.11 | Columncdx6500IBM2260CfgRestConnDest | read-only | mandatory | All calls originating from this port will be routed to the destination specified in this parameter, irrespective of route selection table entries. For example,… |
| 1.3.6.1.4.1.449.2.1.2.1.1.20.1.12 | Columncdx6500IBM2260CfgBillRec | read-only | mandatory | This controls whether billing (accounting) records will be created for calls on this port. |
| 1.3.6.1.4.1.449.2.1.2.1.1.20.1.13 | Columncdx6500IBM2260CfgElectricalInterfaceType | read-only | mandatory | Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 -… |
| 1.3.6.1.4.1.449.2.1.2.1.1.20.1.14 | Columncdx6500IBM2260CfgV24ElectricalInterfaceOption | read-only | mandatory | Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal |
| 1.3.6.1.4.1.449.2.1.2.1.1.20.1.15 | Columncdx6500IBM2260CfgHighSpeedElectricalInterfaceOption | read-only | mandatory | Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable |
| 1.3.6.1.4.1.449.2.1.2.1.3 | Nodecdx6500PCTStationProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.2.1.3.6 | Tablecdx6500SPCTIBM2260StationTable | not-accessible | mandatory | All of the configuration parameters relevant to the IBM2260 Station table. |
| 1.3.6.1.4.1.449.2.1.2.1.3.6.1 | Rowcdx6500SPCTIBM2260StationEntry | not-accessible | mandatory | A row of IBM2260 station configuration parameters. |
| 1.3.6.1.4.1.449.2.1.2.1.3.6.1.1 | Columncdx6500IBM2260sCfgPortNum | read-only | mandatory | Port number. |
| 1.3.6.1.4.1.449.2.1.2.1.3.6.1.2 | Columncdx6500IBM2260sCfgStationNum | read-only | mandatory | Station number. |
| 1.3.6.1.4.1.449.2.1.2.1.3.6.1.3 | Columncdx6500IBM2260sType | read-only | mandatory | single - configures a single station addressable by the ADDR1-ADDR2 address pair. group - configures a group of stations addressable by the ADDR1 address chara… |
| 1.3.6.1.4.1.449.2.1.2.1.3.6.1.4 | Columncdx6500IBM2260sStationAddr1 | read-only | mandatory | This is the first byte of this Station's address. The Station address consists of two hexadecimal digits. The valid range for a digit is: 20-7F; |
| 1.3.6.1.4.1.449.2.1.2.1.3.6.1.5 | Columncdx6500IBM2260sStationAddr2 | read-only | mandatory | This is the second byte of this Station's address. The Station address consists of two hexadecimal digits. The valid range for a digit is: 20-7F |
| 1.3.6.1.4.1.449.2.1.2.1.3.6.1.6 | Columncdx6500IBM2260sCallMnem | read-only | mandatory | This mnemonic name is used if this port is configured for originating connection requests. |
| 1.3.6.1.4.1.449.2.1.2.1.3.6.1.7 | Columncdx6500IBM2260sStationEnable | read-only | mandatory | This parameter is used to disable/enable a station. |
| 1.3.6.1.4.1.449.2.1.3 | Nodecdx6500Statistics | |||
| 1.3.6.1.4.1.449.2.1.3.1 | Nodecdx6500StatProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.3.1.1 | Nodecdx6500PSTPortProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.3.1.1.19 | Tablecdx6500PPSTIBM2260PortTable | not-accessible | mandatory | A list of IBM2260 Port statistics. |
| 1.3.6.1.4.1.449.2.1.3.1.1.19.1 | Rowcdx6500PPSTIBM2260PortEntry | not-accessible | mandatory | An IBM2260 Statistics Table entry. Each entry contains the statistics for a single IBM2260 port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.19.1.1 | Columncdx6500IBM2260StatPortNumber | read-only | mandatory | Physical port number |
| 1.3.6.1.4.1.449.2.1.3.1.1.19.1.2 | Columncdx6500IBM2260StatPortStatus | read-only | mandatory | Operational Status of the port. The different operational statuses are: UP : At least 1 station is responding to polls. DOWN : None of the stations are respond… |
| 1.3.6.1.4.1.449.2.1.3.1.1.19.1.3 | Columncdx6500IBM2260StatPortState | read-only | mandatory | Current State of this port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.19.1.4 | Columncdx6500IBM2260StatPortSpeed | read-only | mandatory | The measured port speed in bits per second. |
| 1.3.6.1.4.1.449.2.1.3.1.1.19.1.5 | Columncdx6500IBM2260StatPortUtilin | read-only | mandatory | The amount of the port's bandwidth that is being utilized; because IBM2260 is a half-duplex protocol the utilization is calculated as the sum of the receive an… |
| 1.3.6.1.4.1.449.2.1.3.1.1.19.1.6 | Columncdx6500IBM2260StatPortUtilOut | read-only | mandatory | The amount of the port's bandwidth that is being utilized; because IBM2260 is a half-duplex protocol the utilization is calculated as the sum of the receive an… |
| 1.3.6.1.4.1.449.2.1.3.1.1.19.1.7 | Columncdx6500IBM2260StatParityErrors | read-only | mandatory | The number of character parity errors counted by the I/O driver. |
| 1.3.6.1.4.1.449.2.1.3.1.1.19.1.8 | Columncdx6500IBM2260StatOverrunErrors | read-only | mandatory | The number of received character overruns counted by the I/O driver. |
| 1.3.6.1.4.1.449.2.1.3.1.1.19.1.9 | Columncdx6500IBM2260StatFramingErrors | read-only | mandatory | The number of asynchronous chracters received which violated the character framing of start and stop bits. Note, this statistic is only valid if the port is co… |
| 1.3.6.1.4.1.449.2.1.3.1.1.19.1.10 | Columncdx6500IBM2260StatBCCErrors | read-only | mandatory | The number of BCC errors counted by the I/O driver. |
| 1.3.6.1.4.1.449.2.1.3.1.1.19.1.11 | Columncdx6500IBM2260StatNoResponse | read-only | mandatory | The number of times the response timer has expired. |
| 1.3.6.1.4.1.449.2.1.3.1.1.19.1.12 | Columncdx6500IBM2260StatCharInTotal | read-only | mandatory | Total number of chracters received to present. |
| 1.3.6.1.4.1.449.2.1.3.1.1.19.1.13 | Columncdx6500IBM2260StatCharOutTotal | read-only | mandatory | Total number of chracters transmitted to present. |
| 1.3.6.1.4.1.449.2.1.3.1.1.19.1.14 | Columncdx6500IBM2260StatCharInSecond | read-only | mandatory | Average number of characters received to present. |
| 1.3.6.1.4.1.449.2.1.3.1.1.19.1.15 | Columncdx6500IBM2260StatCharOutSecond | read-only | mandatory | Average number of characters transmitted to present. |
| 1.3.6.1.4.1.449.2.1.3.1.1.19.1.16 | Columncdx6500IBM2260StatPosAckIn | read-only | mandatory | Number of ACKs received. |
| 1.3.6.1.4.1.449.2.1.3.1.1.19.1.17 | Columncdx6500IBM2260StatPosAckOut | read-only | mandatory | Number of ACKs transmitted. |
| 1.3.6.1.4.1.449.2.1.3.1.1.19.1.18 | Columncdx6500IBM2260StatNegAckIn | read-only | mandatory | Number of NAKs received. |
| 1.3.6.1.4.1.449.2.1.3.1.1.19.1.19 | Columncdx6500IBM2260StatNegAckOut | read-only | mandatory | Number of NAKs transmitted. |
| 1.3.6.1.4.1.449.2.1.3.1.1.19.1.20 | Columncdx6500IBM2260StatMsgRetran | read-only | mandatory | Number of messages retransmitted due to NAKs or timeouts to present. |
| 1.3.6.1.4.1.449.2.1.3.1.3 | Nodecdx6500PSTStationProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.4 | Nodecdx6500Controls |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| DisplayString | OCTET STRING |