IEEE8021-ST-MIB
41 objects
The Bridge MIB module for managing devices that support the Scheduled Traffic Enhancements for IEEE 802.1Q Bridges. Unless otherwise indicated, the references in this MIB module are to IEEE Std 802.1Q. Copyright (C) IEEE (2018). This version of this MIB module is part of IEEE Std 802.1Q; see the draft itself for full legal notices.
Imported Objects
| IEEE8021-BRIDGE-MIB | ieee8021BridgeBaseComponentId ieee8021BridgeBasePort |
| IEEE8021-TC-MIB | ieee802dot1mibs |
| SNMPv2-CONF | MODULE-COMPLIANCE OBJECT-GROUP |
| SNMPv2-SMI | Counter64 MODULE-IDENTITY OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | TEXTUAL-CONVENTION TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.111.2.802.1.1.30 | Identityieee8021STMib | The Bridge MIB module for managing devices that support the Scheduled Traffic Enhancements for IEEE 802.1Q Bridges. Unless otherwise indicated, the references … | ||
| 1.3.111.2.802.1.1.30.0 | Nodeieee8021STNotifications | |||
| 1.3.111.2.802.1.1.30.1 | Nodeieee8021STObjects | |||
| 1.3.111.2.802.1.1.30.1.1 | Nodeieee8021STMaxSDUSubtree | |||
| 1.3.111.2.802.1.1.30.1.1.1 | Tableieee8021STMaxSDUTable | not-accessible | current | A table containing a set of max SDU parameters, one for each traffic class. All writeable objects in this table must be persistent over power up restart/reboot. |
| 1.3.111.2.802.1.1.30.1.1.1.1 | Rowieee8021STMaxSDUEntry | not-accessible | current | A list of objects containing Max SDU size for each traffic class supported by the Port. |
| 1.3.111.2.802.1.1.30.1.1.1.1.1 | Columnieee8021STTrafficClass | not-accessible | current | The traffic class number associated with the row of the table. A row in this table is created for each traffic class that is supported by the Port |
| 1.3.111.2.802.1.1.30.1.1.1.1.2 | Columnieee8021STMaxSDU | read-write | current | The value of the MaxSDU parameter for the traffic class. This value is represented as an unsigned integer. A value of 0 is interpreted as the max SDU size supp… |
| 1.3.111.2.802.1.1.30.1.1.1.1.3 | Columnieee8021TransmissionOverrun | read-only | current | A counter of transmission overrun events, where a PDU is still being transmitted by a MAC at the time when the transmission gate for the queue closed. |
| 1.3.111.2.802.1.1.30.1.2 | Nodeieee8021STParameters | |||
| 1.3.111.2.802.1.1.30.1.2.1 | Tableieee8021STParametersTable | not-accessible | current | A table that contains the per-port manageable parameters for traffic scheduling. For a given Port, a row in the table exists. All writable objects in this tabl… |
| 1.3.111.2.802.1.1.30.1.2.1.1 | Rowieee8021STParametersEntry | not-accessible | current | A list of objects that contains the manageable parameters for traffic scheduling for a port. |
| 1.3.111.2.802.1.1.30.1.2.1.1.1 | Columnieee8021STGateEnabled | read-write | current | The GateEnabled parameter determines whether traffic scheduling is active (true) or inactive (false). The value of this object MUST be retained across reinitia… |
| 1.3.111.2.802.1.1.30.1.2.1.1.2 | Columnieee8021STAdminGateStates | read-write | current | The administrative value of the GateStates parameter for the Port. The bits of the octet represent the gate states for the corresponding traffic classes; the M… |
| 1.3.111.2.802.1.1.30.1.2.1.1.3 | Columnieee8021STOperGateStates | read-only | current | The operational value of the GateStates parameter for the Port. The bits of the octet represent the gate states for the corresponding traffic classes; the MS b… |
| 1.3.111.2.802.1.1.30.1.2.1.1.4 | Columnieee8021STAdminControlListLength | read-write | current | The administrative value of the ListMax parameter for the Port. The integer value indicates the number of entries (TLVs) in the AdminControlList. The value of … |
| 1.3.111.2.802.1.1.30.1.2.1.1.5 | Columnieee8021STOperControlListLength | read-only | current | The operational value of the ListMax parameter for the Port. The integer value indicates the number of entries (TLVs) in the OperControlList. |
| 1.3.111.2.802.1.1.30.1.2.1.1.6 | Columnieee8021STAdminControlList | read-write | current | The administrative value of the ControlList parameter for the Port. The octet string value represents the contents of the control list as an ordered list of en… |
| 1.3.111.2.802.1.1.30.1.2.1.1.7 | Columnieee8021STOperControlList | read-only | current | The operational value of the ListMax parameter for the Port. The octet string value represents the contents of the control list as an ordered list of TLVs, as … |
| 1.3.111.2.802.1.1.30.1.2.1.1.8 | Columnieee8021STAdminCycleTimeNumerator | read-write | current | The administrative value of the numerator of the CycleTime parameter for the Port. The numerator and denominator together represent the cycle time as a rationa… |
| 1.3.111.2.802.1.1.30.1.2.1.1.9 | Columnieee8021STAdminCycleTimeDenominator | read-write | current | The administrative value of the denominator of the CycleTime parameter for the Port. The numerator and denominator together represent the cycle time as a ratio… |
| 1.3.111.2.802.1.1.30.1.2.1.1.10 | Columnieee8021STOperCycleTimeNumerator | read-only | current | The operational value of the numerator of the CycleTime parameter for the Port. The numerator and denominator together represent the cycle time as a rational n… |
| 1.3.111.2.802.1.1.30.1.2.1.1.11 | Columnieee8021STOperCycleTimeDenominator | read-only | current | The operational value of the denominator of the CycleTime parameter for the Port. The numerator and denominator together represent the cycle time as a rational… |
| 1.3.111.2.802.1.1.30.1.2.1.1.12 | Columnieee8021STAdminCycleTimeExtension | read-write | current | The administrative value of the CycleTimeExtension parameter for the Port. The value is an unsigned integer number of nanoseconds. The value of this object MUS… |
| 1.3.111.2.802.1.1.30.1.2.1.1.13 | Columnieee8021STOperCycleTimeExtension | read-only | current | The operational value of the CycleTimeExtension parameter for the Port. The value is an unsigned integer number of nanoseconds. |
| 1.3.111.2.802.1.1.30.1.2.1.1.14 | Columnieee8021STAdminBaseTime | read-write | current | The administrative value of the BaseTime parameter for the Port. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of sec… |
| 1.3.111.2.802.1.1.30.1.2.1.1.15 | Columnieee8021STOperBaseTime | read-only | current | The operationsl value of the BaseTime parameter for the Port. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of second… |
| 1.3.111.2.802.1.1.30.1.2.1.1.16 | Columnieee8021STConfigChange | read-write | current | The ConfigChange parameter signals the start of a configuration change when it is set to TRUE. This should only be done when the various administrative paramet… |
| 1.3.111.2.802.1.1.30.1.2.1.1.17 | Columnieee8021STConfigChangeTime | read-only | current | The PTPtime at which the next config change is scheduled to occur. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of s… |
| 1.3.111.2.802.1.1.30.1.2.1.1.18 | Columnieee8021STTickGranularity | read-only | current | The granularity of the cycle time clock, represented as an unsigned number of tenths of nanoseconds. The value of this object MUST be retained across reinitial… |
| 1.3.111.2.802.1.1.30.1.2.1.1.19 | Columnieee8021STCurrentTime | read-only | current | The current time, in PTPtime, as maintained by the local system. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of sec… |
| 1.3.111.2.802.1.1.30.1.2.1.1.20 | Columnieee8021STConfigPending | read-only | current | The value of the ConfigPending state machine variable. The value is TRUE if a configuration change is in progress but has not yet completed. |
| 1.3.111.2.802.1.1.30.1.2.1.1.21 | Columnieee8021STConfigChangeError | read-only | current | A counter of the number of times that a re-configuration of the traffic schedule has been requested with the old schedule still running and the requested base … |
| 1.3.111.2.802.1.1.30.1.2.1.1.22 | Columnieee8021STSupportedListMax | read-only | current | The maximum value supported by this Port of the AdminControlListLength and OperControlListLength parameters. |
| 1.3.111.2.802.1.1.30.2 | Nodeieee8021STConformance | |||
| 1.3.111.2.802.1.1.30.2.1 | Nodeieee8021STCompliances | |||
| 1.3.111.2.802.1.1.30.2.1.1 | Complianceieee8021STCompliance | current | The compliance statement for devices supporting scheduled traffic. Support of the objects defined in this MIB module also requires support of the IEEE8021-BRID… | |
| 1.3.111.2.802.1.1.30.2.2 | Nodeieee8021STGroups | |||
| 1.3.111.2.802.1.1.30.2.2.1 | Groupieee8021STObjectsGroup | current | Objects that allow management of scheduled traffic. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| IEEE8021STPTPtimeValue | OCTET STRING (SIZE(10)) | current | A PTPtime value, represented as a 48-bit unsigned integer number of seconds and a 32-bit unsigned integer number of nanoseconds. The first 6 octets represent the number of seconds: the first octet is the most significan… |
| IEEE8021STTrafficClassValue | Unsigned32 (0..7) | current | A traffic class value. This is the numerical value associated with a traffic class in a Bridge. Larger values are associated with higher priority traffic classes. |