IEEE8021-TEIPS-V2-MIB
50 objects
Copyright (C) IEEE. All Rights Reserved This MIB module is part of IEEE 802.1Q; See the IEEE 802.1Q standard for full legal notices. Unless otherwise indicated, the references in this MIB module are to IEEE Std 802.1Q-2014
Imported Objects
| IEEE8021-BRIDGE-MIB | ieee8021BridgeBaseComponentId |
| IEEE8021-TC-MIB | IEEE8021BridgePortNumber IEEE8021PbbTeTSidId IEEE8021TeipsIpgConfigActiveRequests IEEE8021TeipsIpgConfigAdmin IEEE8021TeipsIpgid ieee802dot1mibs |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | RowStatus StorageType TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.111.2.802.1.1.27 | Identityieee8021TeipsV2Mib | Copyright (C) IEEE. All Rights Reserved This MIB module is part of IEEE 802.1Q; See the IEEE 802.1Q standard for full legal notices. Unless otherwise indicated… | ||
| 1.3.111.2.802.1.1.27.0 | Nodeieee8021TeipsV2Notifications | |||
| 1.3.111.2.802.1.1.27.0.1 | Notificationieee8021TeipsV2IpgAdminFailure | current | An IPG generates this notification whenever an adminisistrative command cannot be executed by the IPS state machine. For example, when a requested manual switc… | |
| 1.3.111.2.802.1.1.27.1 | Nodeieee8021TeipsV2Objects | |||
| 1.3.111.2.802.1.1.27.1.1 | Tableieee8021TeipsV2IpgTable | not-accessible | current | The IPG table. Each entry in this table corresponds to an Infrastructure Protection Group (IPG) associated with a PBB supporting Infrastructure Protection Swit… |
| 1.3.111.2.802.1.1.27.1.1.1 | Rowieee8021TeipsV2IpgEntry | not-accessible | current | The IPG table entry. |
| 1.3.111.2.802.1.1.27.1.1.1.1 | Columnieee8021TeipsV2Ipgid | not-accessible | current | Uniquely identifies an IPG within the PBB. |
| 1.3.111.2.802.1.1.27.1.1.1.2 | Columnieee8021TeipsV2IpgWorkingMA | read-create | current | Identifies the Segment MA that corresponds to the IPG's working entity. The MA index in this column must hold a value that is the value of dot1agCfmStackMaInde… |
| 1.3.111.2.802.1.1.27.1.1.1.3 | Columnieee8021TeipsV2IpgProtectionMA | read-create | current | Identifies the Segment MA that corresponds to the IPG's protection entity. The MA index in this column must hold a value that is the value of dot1agCfmStackMaI… |
| 1.3.111.2.802.1.1.27.1.1.1.4 | Columnieee8021TeipsV2IpgWorkingPortNumber | read-only | current | Identifies the local Port associated with the IPG Working Segment. |
| 1.3.111.2.802.1.1.27.1.1.1.5 | Columnieee8021TeipsV2IpgProtectionPortNumber | read-only | current | Identifies the local Port associated with the IPG Protection Segment. |
| 1.3.111.2.802.1.1.27.1.1.1.6 | Columnieee8021TeipsV2IpgStorageType | read-create | current | This object indicates the persistence of this entry. All read-create columns must be writable if this column is set to permanent. |
| 1.3.111.2.802.1.1.27.1.1.1.7 | Columnieee8021TeipsV2IpgRowStatus | read-create | current | The status of this row. The writable columns in a row cannot be changed if the row is active. The TeipsIpgWorkingMA and TeipsIpgProtectionMA columns must be sp… |
| 1.3.111.2.802.1.1.27.1.2 | Tableieee8021TeipsV2TesiTable | not-accessible | current | The IPG TE-SID table contains identifies the TE service instances associated with an IPG. |
| 1.3.111.2.802.1.1.27.1.2.1 | Rowieee8021TeipsV2TesiEntry | not-accessible | current | The TE-IPS TESI entry. Each entry identifies a TESI associated with an IPG. |
| 1.3.111.2.802.1.1.27.1.2.1.1 | Columnieee8021TeipsV2TesiIndex | not-accessible | current | This is an identifier, of local signifigance to a particular PBB-TE TE-SID associated with an IPG. |
| 1.3.111.2.802.1.1.27.1.2.1.2 | Columnieee8021TeipsV2TesiId | read-create | current | This column holds the TESI identifier corresponding to a TE service instance associated with an IPG. |
| 1.3.111.2.802.1.1.27.1.2.1.3 | Columnieee8021TeipsV2TesiStorageType | read-create | current | This object indicates the persistence of this entry. All read-create columns must be writable for permanent rows. |
| 1.3.111.2.802.1.1.27.1.2.1.4 | Columnieee8021TeipsV2TesiRowStatus | read-create | current | This column holds the status for this row. When the status is active, no columns of this table may be modified. All columns must have a valid value before the … |
| 1.3.111.2.802.1.1.27.1.3 | Tableieee8021TeipsV2CandidatePsTable | not-accessible | current | The Candidate PS table lists, in priority order, from highest priority to lowest priority, the Maintenance Associations corresponding to candidate Protection S… |
| 1.3.111.2.802.1.1.27.1.3.1 | Rowieee8021TeipsV2CandidatePsEntry | not-accessible | current | A Candidate PS entry. Each entry identifies a candidate Protection Segment associated with an IPG. |
| 1.3.111.2.802.1.1.27.1.3.1.1 | Columnieee8021TeipsV2CandidatePsIndex | not-accessible | current | This is an identifier, of local signifigance to a particular candidate Protection Segment associated with an IPG. |
| 1.3.111.2.802.1.1.27.1.3.1.2 | Columnieee8021TeipsV2CandidatePsMA | read-create | current | This column holds the candidate Protection Segment MA corresponding to a candidate Protection Segment associated with an IPG. |
| 1.3.111.2.802.1.1.27.1.3.1.3 | Columnieee8021TeipsV2CandidatePsPort | read-only | current | This column holds the Port Number corresponding to the candidate Protection Segment associated with an IPG. |
| 1.3.111.2.802.1.1.27.1.3.1.4 | Columnieee8021TeipsV2CandidatePsOper | read-only | current | This column indicates whether or not the candidate Protection Segment is operational. |
| 1.3.111.2.802.1.1.27.1.3.1.5 | Columnieee8021TeipsV2CandidatePsStorageType | read-create | current | This object indicates the persistence of this entry. All read-create columns must be writable for permanent rows. |
| 1.3.111.2.802.1.1.27.1.3.1.6 | Columnieee8021TeipsV2CandidatePsRowStatus | read-create | current | This column holds the status for this row. When the status is active, no columns of this table may be modified. All columns must have a valid value before the … |
| 1.3.111.2.802.1.1.27.1.4 | Tableieee8021TeipsV2IpgConfigTable | not-accessible | current | The PBB-TE IPS IPG config table contains configuration and status information for each IPG configured in the system. Entries in this table are created implicit… |
| 1.3.111.2.802.1.1.27.1.4.1 | Rowieee8021TeipsV2IpgConfigEntry | not-accessible | current | The IPG confguration table entry. Rows are created in this table implicitly when a row is added to the ieee8021TeipsV2IpgTable. |
| 1.3.111.2.802.1.1.27.1.4.1.1 | Columnieee8021TeipsV2IpgConfigState | read-only | current | This column indicates the current state of the protection switching state machine for an IPG. The value can be one of the following: workingSegment(1) The prot… |
| 1.3.111.2.802.1.1.27.1.4.1.2 | Columnieee8021TeipsV2IpgConfigCommandStatus | read-only | current | This column indicates the status of administrative commands within the protection group. It reflects the current operational administrative command being acted… |
| 1.3.111.2.802.1.1.27.1.4.1.3 | Columnieee8021TeipsV2IpgConfigCommandLast | read-only | current | This column indicates the last attempted administrative command applied to the IPG. It is changed whenever a write is made to the CommandAdmin column of this t… |
| 1.3.111.2.802.1.1.27.1.4.1.4 | Columnieee8021TeipsV2IpgConfigCommandAdmin | read-create | current | This column is used by the operator to request that the IPG state machine perform some administrative operation. The operator requests a command by writing the… |
| 1.3.111.2.802.1.1.27.1.4.1.5 | Columnieee8021TeipsV2IpgConfigActiveRequests | read-only | current | This column shows the status of active requests associated with the IPG. |
| 1.3.111.2.802.1.1.27.1.4.1.6 | Columnieee8021TeipsV2IpgConfigWTR | read-create | current | This column is used to configure the wait-to-restore timer for the IPG operation. The timer may be configured in steps of 1 minute between 5 and 12 minutes, th… |
| 1.3.111.2.802.1.1.27.1.4.1.7 | Columnieee8021TeipsV2IpgConfigHoldOff | read-create | current | This column is used to configure the hold off timer. The purpose is to allow IPS to fix the problem before a higher-layer mechanism, such as PBB-TE TESI protec… |
| 1.3.111.2.802.1.1.27.1.4.1.8 | Columnieee8021TeipsV2IpgM1ConfigState | read-only | current | This column indicates the current state of the M:1 protection switching state machine for an IPG if M:1 IPS is supported. The value can be one of the following… |
| 1.3.111.2.802.1.1.27.1.4.1.9 | Columnieee8021TeipsV2IpgConfigMWTR | read-create | current | This column is used to configure the M:1 wait-to-restore timer for the IPG operation if M:1 protection is supported. The timer may be configured in steps of 1 … |
| 1.3.111.2.802.1.1.27.1.4.1.10 | Columnieee8021TeipsV2IpgConfigNotifyEnable | read-create | current | This column is used to enable or disable transmission of ieee8021TeipsV2IpgAdminFailure notifications. These notifications are generated whenever an administra… |
| 1.3.111.2.802.1.1.27.1.4.1.11 | Columnieee8021TeipsV2IpgConfigStorageType | read-create | current | This object indicates the persistence of this entry. For permanent objects the ieee8021TeipsV2IpgConfigCommandAdmin column must be writable. |
| 1.3.111.2.802.1.1.27.2 | Nodeieee8021TeipsV2Conformance | |||
| 1.3.111.2.802.1.1.27.2.1 | Nodeieee8021TeipsV2Compliances | |||
| 1.3.111.2.802.1.1.27.2.1.1 | Complianceieee8021TeipsV2Compliance | not-accessible | current | The compliance statement for support of the TEIPS MIB module. |
| 1.3.111.2.802.1.1.27.2.2 | Nodeieee8021TeipsV2Groups | |||
| 1.3.111.2.802.1.1.27.2.2.1 | Groupieee8021TeipsV2IpgGroup | current | Objects for the IPG group. | |
| 1.3.111.2.802.1.1.27.2.2.2 | Groupieee8021TeipsV2CandidatePsGroup | current | Objects for the Candidate PS group. | |
| 1.3.111.2.802.1.1.27.2.2.3 | Groupieee8021TeipsV2IpgTesiGroup | current | Objects for the IPG Tuple group. | |
| 1.3.111.2.802.1.1.27.2.2.4 | Groupieee8021TeipsV2IpgConfigManGroup | current | Mandatory objects for the TeipsConfiguration group. | |
| 1.3.111.2.802.1.1.27.2.2.5 | Groupieee8021TeipsV2IpgConfigOptGroup | current | Optional 0bjects for the TeipsConfiguration group. | |
| 1.3.111.2.802.1.1.27.2.2.6 | Groupieee8021TeipsV2NotificationsGroup | current | Objects for the notifications group. |