MIB Viewer

INNOVX-DTE-MIB

17 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.498.22.1.6.1NodedteAdmin
1.3.6.1.4.1.498.22.1.6.1.1ScalardtesMIBversionread-onlymandatoryIdentifies the version of the MIB as `X.YZT' where: X: Major Revision (1-9) Y: Minor Revision (0-9) Z: Typographical Revision (0-9) T: Test Revision (A-Z) Upon…
1.3.6.1.4.1.498.22.1.6.2NodedteCfg
1.3.6.1.4.1.498.22.1.6.2.1ScalardteInterfaceTyperead-writemandatoryDefines the DTE Interface Type. WEBFLAG V.28 V.35 RS-449 EIA-530 EIA-530A X.21 WEBEND
1.3.6.1.4.1.498.22.1.6.2.2ScalardteTxInvertingTimingread-writemandatorynormal(1) tx timing clocks the transmit data from the DTE using an internal generated clock. invert (2) Invert Internally generated transmit clock used to samp…
1.3.6.1.4.1.498.22.1.6.2.3ScalardteRxCarrierread-writemandatoryThe Receive Carrier option. This option controls the operation of DCD. WEBFLAG Forced On Normal Operation WEBEND
1.3.6.1.4.1.498.22.1.6.2.4ScalardteDsrControlread-writemandatoryThe DSR option. This option controls the operation of DSR. When forcedOn(1) is selected, DSR is normally on, if set for followsDTR(2) then DSR is on only when …
1.3.6.1.4.1.498.22.1.6.3NodedteAlarmCfg
1.3.6.1.4.1.498.22.1.6.3.1ScalardteDtrLossTrapSeverityread-writemandatoryControls the reporting and defines the severity of the Channel Data Terminal Ready Loss Alarm when this event occurs. WEBFLAG Inhibit Critical Major Minor Warn…
1.3.6.1.4.1.498.22.1.6.4NodedteDiagnostics
1.3.6.1.4.1.498.22.1.6.4.1ScalardteLoopbackread-writemandatoryControl the DTE loopback to the channel. noTest(1) stops the test. toChan(2) starts a loopback toward the DTE.
1.3.6.1.4.1.498.22.1.6.4.2ScalardteDiagTestDurationread-writemandatoryDefines the length of the diagnostic test.
1.3.6.1.4.1.498.22.1.6.4.3ScalardteDiagTestStatusread-onlymandatoryDisplays the test in progress, if any.
1.3.6.1.4.1.498.22.1.6.5NodedteStatus
1.3.6.1.4.1.498.22.1.6.5.1ScalardteLedStatusread-onlymandatoryA bitwise snapshot of the front panel LED states, where 0 = LED off and 1 = LED on, as follows: LED description Octet 1 bit 7 - n/u bit 6 - n/u bit 5 - n/u bit…
1.3.6.1.4.1.498.22.1.6.5.2ScalardtePortStatusread-onlymandatoryA bitwise snapshot of interface port status conditions and EIA signals, where 0 = condition not present, and 1 = condition present, as follows: Octet 1 - DTE I…
1.3.6.1.4.1.498.22.1.6.5.3ScalardtePortFrameCountsread-onlymandatoryThe total number of frames transmitted and received on each interface port. This object will be reset to zero after a read, and after power up, soft reset, or …