MIB Viewer

INXNMM-MIB

274 objects
No module-level DESCRIPTION found.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1Nodeinternet
1.3.6.1.3Nodeexperimental
1.3.6.1.3.3Nodedot3
1.3.6.1.3.3.1Tabledot3Tablenot-accessiblemandatoryA list of the INX-NMM Ethernet interface's operational attributes, such as whether it is configured for multicast receive and the status of the MAC sublayer . …
1.3.6.1.3.3.1.1Rowdot3Entrynot-accessiblemandatoryAn entry in the INX-NMM Interface table. (See the previous variable, INX-NMM Interface Table, for an explanation of this table.) You cannot access this variabl…
1.3.6.1.3.3.1.1.1Columndot3Indexread-onlymandatoryThe value assigned to the INX-NMM Ethernet interface. Because the INX-NMM has only one interface, this variable always returns 1.
1.3.6.1.3.3.1.1.2Columndot3InitializeMACread-writemandatoryThe initialization status of the MAC and PLS subsystems of the interface. Because the MAC and PLS subsystems on the INX-NMM are initialized at power-up and rem…
1.3.6.1.3.3.1.1.3Columndot3MACSubLayerStatusread-writemandatoryThe operational status of the MAC sublayer, i.e., whether it is ready to transmit and receive frames. Because this sublayer is always active in the INX-NMM, th…
1.3.6.1.3.3.1.1.4Columndot3MulticastReceiveEnabledread-writemandatoryThe Multicast Receive status, i.e., whether the INX-NMM is configured to receive frames with a multicast address. Because Multicast Receive is always enabled o…
1.3.6.1.3.3.1.1.5Columndot3AlignmentErrorsread-onlymandatoryThe number of frames received on the interface that are not an integral number of octets in length (i.e., the number of bits they contain is not a multiple of …
1.3.6.1.3.3.1.1.6Columndot3FCSErrorsread-onlymandatoryThe number of frames received on the interface that are an integral number of octets in length (i.e., the number of bits they contain is a multiple of eight) t…
1.3.6.1.3.3.2Tabledot3TxTablenot-accessiblemandatoryA list of transmit errors and statistics for the INX-NMM Ethernet interface. You cannot access this variable; it is only a table marker in the MIB.
1.3.6.1.3.3.2.1Rowdot3TxEntrynot-accessiblemandatoryAn entry in the Interface Transmit table. (See the previous variable, Interface Transmit Table, for an explanation of this table.) You cannot access this varia…
1.3.6.1.3.3.2.1.1Columndot3TxIndexread-onlymandatoryThe value assigned to the INX-NMM Ethernet interface. Because the INX-NMM has only one interface, this variable always returns 1.
1.3.6.1.3.3.2.1.2Columndot3TxSingleCollisionFramesread-onlymandatoryThe number of frames that were successfully transmitted after experiencing one and only one collision.
1.3.6.1.3.3.2.1.3Columndot3TxMultipleCollisionFramesread-onlymandatoryThe number of frames that were successfully transmitted after experiencing more than one collision.
1.3.6.1.3.3.2.1.4Columndot3TxSQETestErrorsread-onlymandatoryThe number of times that the SQE TEST ERROR message has been generated by this interface's PLS sublayer. The PLS sublayer generates an SQE test error message w…
1.3.6.1.3.3.3Tabledot3XRxTablenot-accessiblemandatoryA list of receive errors and statistics for the INX-NMM Ethernet interface. You cannot access this variable; it is only a table marker in the MIB.
1.3.6.1.3.3.3.1Rowdot3XRxEntrynot-accessiblemandatoryAn entry in the Interface Receive table. (See the previous variable, Interface Receive Table, for an explanation of this table.) You cannot access this variabl…
1.3.6.1.3.3.3.1.1Columndot3XRxIndexread-onlymandatoryThe value assigned to the INX-NMM Ethernet interface. Because the INX-NMM has only one interface, this variable always returns 1.
1.3.6.1.3.3.3.1.2Columndot3XRxFrameTooLongsread-onlymandatoryThe number of frames received on the interface that exceed the maximum permitted frame size, i.e., 1012 octets.
1.3.6.1.3.3.3.1.3Columndot3XRxInRangeLengthErrorsread-onlymandatoryThe number of in-range length errors received. IEEE 802.3 frames contain a length field, indicating the length of the frame. If the value in the length field a…
1.3.6.1.3.3.3.1.4Columndot3XRxOutOfRangeLengthFieldsread-onlymandatoryThe number of out-of-range length errors received. IEEE 802.3 frames contain a length field, indicating the length of the frame. If the length of the frame is …
1.3.6.1.3.3.3.1.5Columndot3XRxInternalMACReceiveErrorsread-onlymandatoryThe number of frames the interface could not receive because of an internal MAC sublayer receive error. This variable returns frames not counted by the Too Lon…
1.3.6.1.3.3.3.1.6Columndot3XRxAutoPartitionStatusread-writemandatoryThe autopartition status of the INX-NMM. Devices that support autopartitioning have the ability to autonomously disconnect from the network when they sense tro…
1.3.6.1.3.3.3.1.7Columndot3XRxAutoPartitionLogread-onlymandatoryThe number of autopartitions the INX-NMM has performed. Devices that support autopartitioning maintain a log of the number of times they disconnected from the …
1.3.6.1.3.3.3.1.8Columndot3XRxLastSourceAddressread-onlymandatoryThe source address of the last frame successfully received. Because this value changes too often to be useful, the INX-NMM interface does not record the last s…
1.3.6.1.3.3.3.1.9Columndot3XRxSourceAddressLogread-onlymandatoryThe number of times that the value of Last Good Source Address has changed. The INX-NMM interface does not log source address changes; therefore, this variable…
1.3.6.1.3.3.4Tabledot3XTxTablenot-accessiblemandatoryA list of transmit errors and statistics for the INX-NMM Ethernet interface. You cannot access this variable; it is only a table marker in the MIB.
1.3.6.1.3.3.4.1Rowdot3XTxEntrynot-accessiblemandatoryAn entry in the Interface Xmit Error/Stat table. (See the previous variable, Interface Xmit Error/Stat Table, for an explanation of this table.) You cannot acc…
1.3.6.1.3.3.4.1.1Columndot3XTxIndexread-onlymandatoryThe value assigned to the INX-NMM Ethernet interface. Because the INX-NMM has only one interface, this variable always returns 1.
1.3.6.1.3.3.4.1.2Columndot3XTxEnabledread-writemandatoryThe transmit status of the interface, i.e., whether it is able to transmit frames. Because transmit is always enabled on the INX-NMM, this variable always retu…
1.3.6.1.3.3.4.1.3Columndot3XTxDeferredTransmissionsread-onlymandatoryThe number of times the INX-NMM deferred transmission of data because it sensed traffic on the network. Because the INX-NMM does not record deferrals, this var…
1.3.6.1.3.3.4.1.4Columndot3XTxLateCollisionsread-onlymandatoryThe number of times that a collision has been detected on this bus later than 512 bit times from frame start. This count is not maintained by the INX-NMM, so t…
1.3.6.1.3.3.4.1.5Columndot3XTxExcessiveCollisionsread-onlymandatoryThe number of frames the interface could not transmit because of excessive collisions.
1.3.6.1.3.3.4.1.6Columndot3XTxInternalMACTransmitErrorsread-onlymandatoryThe number of frames the interface could not transmit because of an internal MAC sublayer transmit error. This variable counts frames not counted by the Late C…
1.3.6.1.3.3.4.1.7Columndot3XTxCarrierSenseErrorsread-onlymandatoryThe number of times that the carrier-sense condition was lost or never asserted when the INX-NMM attempted to transmit a frame on the interface. This count is …
1.3.6.1.3.3.4.1.8Columndot3XTxExcessiveDeferralsread-onlymandatoryThe number of frames the INX-NMM deferred transmitting for an excessive period of time. Because the INX-NMM interface does not record deferrals, this variable …
1.3.6.1.3.3.4.1.9Columndot3XTxTDRread-onlymandatoryThe status of Time Domain Reflectometry (TDR) on the INX-NMM. TDR is the ability of a device to check the viability of a cable by sending a signal to the end o…
1.3.6.1.3.3.5Tabledot3CollTablenot-accessiblemandatoryA histogram representing the frequency of collisions on the interface. In the Collision Frequency histogram, one dimension of each cell represents Collisions p…
1.3.6.1.3.3.5.1Rowdot3CollEntrynot-accessiblemandatoryAn entry in the Collision Frequency table. (See the previous variable, Collision Frequency Table, for an explanation of this table.) You cannot access this var…
1.3.6.1.3.3.5.1.1Columndot3CollIndexread-onlymandatoryThe value assigned to the INX-NMM Ethernet interface. Because the INX-NMM has only one interface, this variable always returns 1.
1.3.6.1.3.3.5.1.2Columndot3CollCountread-onlymandatoryThe number of media collisions per frame indicated by one cell in the collision histogram. The INX-NMM tracks the number of collisions up to 15.
1.3.6.1.3.3.5.1.3Columndot3CollFrequencyread-onlymandatoryThe number of frames that were transmitted after experiencing exactly Collisions per Frame collisions on the INX-NMM Ethernet interface (see the previous varia…
1.3.6.1.4Nodeprivate
1.3.6.1.4.1Nodeenterprises
1.3.6.1.4.1.28Nodeinterlan
1.3.6.1.4.1.28.1NoderiProducts
1.3.6.1.4.1.28.1.3NoderiProdLdc
1.3.6.1.4.1.28.1.3.1NoderiPLdcNMM
1.3.6.1.4.1.28.3NoderiTelnet
1.3.6.1.4.1.28.3.1ScalartnCountread-onlymandatoryThe number of telnet sessions that have been initiated from the INX-NMM. Because the INX-NMM doesn't initiate sessions, this variable always returns 0.
1.3.6.1.4.1.28.3.2TabletnTablenot-accessiblemandatoryContains telnet session-specific information that is appropriate to either the server or client side of a session. You cannot access this variable; it is only …
1.3.6.1.4.1.28.3.2.1RowtnEntrynot-accessiblemandatoryAn entry in the Telnet Session table. (See the previous variable, Telnet Session Table, for an explanation of this table.) There is one entry in the table for …
1.3.6.1.4.1.28.3.2.1.1ColumntnPortread-onlymandatoryAn internal index in the INX-NMM.
1.3.6.1.4.1.28.3.2.1.2ColumntnLocalIpAddressread-onlymandatoryThe local IP address of the TCP connection that this telnet session is using. The value of this variable is the same as the value of the Connection Local Addre…
1.3.6.1.4.1.28.3.2.1.3ColumntnRemoteIpAddressread-onlymandatoryThe remote IP address of the TCP connection that this telnet session is using. The value of this variable is the same as the value of the Connection Remote Add…
1.3.6.1.4.1.28.3.2.1.4ColumntnLocalPortread-onlymandatoryThe local port of the TCP connection that this telnet session is using. The value of this variable is the same as the value of the Connection Local Port Number…
1.3.6.1.4.1.28.3.2.1.5ColumntnRemotePortread-onlymandatoryThe remote port of the TCP connection that this telnet session is using. The value of this variable is the same as the value of the Connection Remote Port Numb…
1.3.6.1.4.1.28.3.2.1.6ColumntnUpTimeread-onlymandatoryThe value of INX-NMM Up Time at the time the telnet session was established.
1.3.6.1.4.1.28.3.2.1.7ColumntnOptionsOnread-onlymandatoryIndicates which options are on/enabled in the will/do state. Each octet in the string contains the numerical value of an option that is on. For example, if a s…
1.3.6.1.4.1.28.3.2.1.8ColumntnStateread-onlymandatoryShows the state of the session. This variable always returns serverActive(1), which indicates that the INX-NMM is the telnet server and that a session is activ…
1.3.6.1.4.1.28.3.2.1.9ColumntnUserIdread-onlymandatoryThe identification of the actual user at that end of the telnet session. The INX-NMM always returns a null string for this variable, because the concept of a u…
1.3.6.1.4.1.28.10NoderiLdcNmm
1.3.6.1.4.1.28.10.1ScalarriLdcHardwareRevread-onlymandatoryThe hardware revision level of the INX-CMM, which this variable returns as a hexadecimal display string. Note: This is NOT the hardware revision level of the I…
1.3.6.1.4.1.28.10.2ScalarriLdcFirmwareRevread-onlymandatoryThe firmware revision level of the INX-CMM, i.e., the revision level of the INX-CMM PROMs. Note: This is NOT the firmware revision level of the INX-NMM module.
1.3.6.1.4.1.28.10.3ScalarriLdcChassisSoftwareRevread-onlymandatoryThe software revision level of higher-level INX-CMM software. Currently, there is no higher-level software on the INX-CMM; all its software is contained in the…
1.3.6.1.4.1.28.10.4ScalarriLdcChassisSerialNumberread-onlymandatoryThe logic module serial number of the INX-CMM.
1.3.6.1.4.1.28.10.5ScalarriLdcChassisStatusread-writemandatoryThe state of the modules in the chassis. This variable returns enabled(6) if any module in the chassis is set to enabled(6). It returns disabled(7) when all mo…
1.3.6.1.4.1.28.10.6ScalarriLdcChassisSlotCountread-onlymandatoryThe total number of slots available in the chassis for INTERNExT modules. The INX5000-3 contains 3 slots, and the INX5000-12 contains 13 slots.
1.3.6.1.4.1.28.10.7ScalarriLdcNumPowerSuppliesread-onlymandatoryThe number of power supplies that are installed in the INTERNExT chassis. This variable returns either 1 or 2, because the INX5000-3 requires one power supply …
1.3.6.1.4.1.28.10.8ScalarriLdcNumBusMonsread-onlymandatoryThe number of entries in the Bus Monitor table, which contains statistics for the internal INTERNExT chassis buses. This variable always returns 2, because the…
1.3.6.1.4.1.28.10.9ScalarriLdcNumFansread-onlymandatoryThe number of entries in the Fan Status table, which contains information about the chassis fans. This variable returns either 1 or 4, because the INX5000-3 re…
1.3.6.1.4.1.28.10.10TableriLdcChassisSlotTablenot-accessiblemandatoryThe Slot table contains information on the contents of each INTERNExT chassis slot. You cannot access this variable; it is only a table marker in the MIB.
1.3.6.1.4.1.28.10.10.1RowriLdcSlotEntrynot-accessiblemandatoryAn entry in the Slot table. (See the previous variable, Chassis Slot Table, for an explanation of this table.) You cannot access this variable; it is only a ta…
1.3.6.1.4.1.28.10.10.1.1ColumnriLdcSlotIndexread-onlymandatoryA unique value for each slot in the chassis. The value ranges from 1 to n, where n is the number of slots in the chassis. This variable returns 14 for the CMM …
1.3.6.1.4.1.28.10.10.1.2ColumnriLdcSlotContentsread-onlymandatoryThe type of logic module that is in the slot, as specified below. If the slot is empty, this variable returns 0.0. 1.3.6.1.4.1.28.1.3.1.1 INX-NMM 1.3.6.1.4.1.2…
1.3.6.1.4.1.28.10.10.1.3ColumnriLdcSlotAdminStatusread-writemandatoryThe state of the logic module in the slot. To enable or disable a logic module, first set this variable to enabled(6) or disabled(7), then reboot the module by…
1.3.6.1.4.1.28.10.10.1.4ColumnriLdcSlotOperStatusread-onlymandatoryThe current state of the logic module in the slot. empty(31) indicates that there is nothing in the slot; other(200) indicates that the module in the slot has …
1.3.6.1.4.1.28.10.10.1.5ColumnriLdcSlotBusread-writemandatoryThe internal Ethernet bus connected to the NIC of the logic module. The values have the following meanings: o bus-a(2) indicates that the NIC is connected to B…
1.3.6.1.4.1.28.10.10.1.6ColumnriLdcSlotHwRevread-onlymandatoryThe hardware revision level of the logic module in the slot, returned as a hexadecimal string. If the slot is empty, the variable returns 0.
1.3.6.1.4.1.28.10.10.1.7ColumnriLdcSlotFwRevread-onlymandatoryThe firmware revision level of the logic module in the slot. If the slot contains no module, or if the module contains no firmware, the variable returns 0.
1.3.6.1.4.1.28.10.10.1.8ColumnriLdcSlotSwRevread-onlymandatoryThe revision level of the operating software image of the logic module in the slot. If the slot contains no module, or the module has no software, the variable…
1.3.6.1.4.1.28.10.10.1.9ColumnriLdcSlotSerialNumberread-onlymandatoryThe serial number of the logic module in the slot. If the slot is empty, the variable returns 0.
1.3.6.1.4.1.28.10.10.1.10ColumnriLdcSlotDiagnosticread-onlymandatoryThe results of the internal startup (i.e., nondestructive) diagnostics for the logic and connectivity modules in a slot. This variable returns either pass(92) …
1.3.6.1.4.1.28.10.10.1.11ColumnriLdcSlotDiagnosticCoderead-onlymandatoryDiagnostic results, returned as an octet string.
1.3.6.1.4.1.28.10.10.1.12ColumnriLdcSlotResetTimeread-onlymandatoryThe value of INX-NMM Up Time (i.e., the length of time since the INX-NMM was last initialized) when the INX-NMM detected the presence of a logic module in this…
1.3.6.1.4.1.28.10.10.1.13ColumnriLdcSlotTempConditionread-onlymandatoryThe temperature status of the slot. When the slot is empty or when the module in the slot is in some other failure or error state, this variable returns unknow…
1.3.6.1.4.1.28.10.10.1.14ColumnriLdcSlotConnectivityTyperead-onlymandatoryThe type of connectivity module that is in the slot, as specified below. If there is no connectivity module in this slot, or the type cannot be determined, the…
1.3.6.1.4.1.28.10.10.1.15ColumnriLdcSlotConnectivityRevread-onlymandatoryThe hardware revision of the connectivity module in the slot, returned as a hexadecimal string. If the slot is empty, then this variable returns 0.
1.3.6.1.4.1.28.10.10.1.16ColumnriLdcSlotConnectivitySerialNumberread-onlymandatoryThe serial number of the connectivity module in the slot. This variable returns a null string for INX-10BT RJ45 and INX-10BT Telco connectivity modules, becaus…
1.3.6.1.4.1.28.10.10.1.17ColumnriLdcSlotConnectivityStateread-writemandatoryThe state of the connectivity module in the slot. You can enable or disable only INX-AUI and INX-FST connectivity modules with this variable. INX-10BT, INX-NTS…
1.3.6.1.4.1.28.10.10.1.18ColumnriLdcSlotConnectivityBusread-writemandatoryThe bus connected to an INX-AUI or INX-FST connectivity module. o bus-a(8) indicates that the INX-AUI or INX-FST is connected to Bus A. o bus-b(9) indicates th…
1.3.6.1.4.1.28.10.10.1.19ColumnriLdcSlotConnectivityMediaread-writemandatoryThe INX media type for the connectivity module located in this slot. o backbone thick(11) indicates that the media type of the INX-AUI or INX-FST is set for co…
1.3.6.1.4.1.28.10.10.1.20ColumnriLdcSlotSonicBusread-writemandatoryThe internal Ethernet bus that the INX-NMM SONIC is monitoring. o bus-a(15) indicates that the SONIC is monitoring Bus A. o bus-b(16) indicates that the SONIC …
1.3.6.1.4.1.28.10.10.1.21ColumnriLdcSlotModuleTyperead-onlymandatoryThe type of logic module in the specified slot. This variable returns the same information as Logic Module Object ID, but in integer form, rather than as objec…
1.3.6.1.4.1.28.10.10.1.22ColumnriLdcSlotStandbyNMMread-writemandatoryWhether this INX-NMM is in standby mode. For this INX-NMM to be the master, this variable must be set to non-standby-NMM(4) and the Desired Logic Module State …
1.3.6.1.4.1.28.10.11TableriLdcPowerSupplyTablenot-accessiblemandatoryThe Power Supply table contains information on the INTERNExT chassis power supplies. You cannot access this variable; it is only a table marker in the MIB.
1.3.6.1.4.1.28.10.11.1RowriLdcPSEntrynot-accessiblemandatoryAn entry in the Power Supply table. (See the previous variable, Power Supply Table, for an explanation of this table.) You cannot access this variable; it is o…
1.3.6.1.4.1.28.10.11.1.1ColumnriLdcPSIndexread-onlymandatoryA unique value for each power supply in the chassis. Values range from 1 to n, where n is the number of available positions for power supplies in the chassis. …
1.3.6.1.4.1.28.10.11.1.3ColumnriLdcPSActualStatusread-onlymandatoryThe current operational state of the power supply. The values and their meanings are as follows: o off(71) indicates that the power supply in this position is …
1.3.6.1.4.1.28.10.12TableriLdcBusMonTablenot-accessiblemandatoryThe Bus Monitor table maintains traffic statistics on the internal buses of the INTERNExT chassis. You cannot access this variable; it is only a table marker i…
1.3.6.1.4.1.28.10.12.1RowriLdcBusMonEntrynot-accessiblemandatoryEntries in the Bus Monitor table provide statistical information on the activities of the internal Ethernet buses. (See the previous variable, Bus Monitor Tabl…
1.3.6.1.4.1.28.10.12.1.1ColumnriLdcBusMonIndexread-onlymandatoryA unique value for each table entry. The value ranges from 1 to the value of Bus Monitor Entries. 1 for Bus A, 2 for Bus B
1.3.6.1.4.1.28.10.12.1.2ColumnriLdcBusMonBusread-onlymandatoryThe internal Ethernet bus associated with this entry. The INTERNExT chassis contains two internal Ethernet buses, Bus A and Bus B.
1.3.6.1.4.1.28.10.12.1.3ColumnriLdcBusMonFramesReceivedOKread-onlymandatoryThe number of frames received successfully off the bus by the SONIC. This value does not include frames received with FCS, length, or alignment errors, or fram…
1.3.6.1.4.1.28.10.12.1.4ColumnriLdcBusMonFramesReceivedOKRateread-onlymandatoryThe rate of frames received successfully off the bus by the SONIC. This value does not include frames received with FCS, length, or alignment errors, or frames…
1.3.6.1.4.1.28.10.12.1.5ColumnriLdcBusMonOctetsReceivedOKread-onlymandatoryThe number of octets associated with the frames included in Frames Received.
1.3.6.1.4.1.28.10.12.1.6ColumnriLdcBusMonOctetsReceivedOKRateread-onlymandatoryThe rate of octets associated with the frames included in Frames Received.
1.3.6.1.4.1.28.10.12.1.7ColumnriLdcBusMonMCastFramesReceivedOKread-onlymandatoryThe number of frames received successfully off this bus that have an Ethernet multicast destination address.
1.3.6.1.4.1.28.10.12.1.8ColumnriLdcBusMonMCastFramesReceivedOKRateread-onlymandatoryThe rate of frames received successfully off this bus that have an Ethernet multicast destination address.
1.3.6.1.4.1.28.10.12.1.9ColumnriLdcBusMonBCastFramesReceivedOKread-onlymandatoryThe number of frames received successfully off this bus that have a broadcast destination address.
1.3.6.1.4.1.28.10.12.1.10ColumnriLdcBusMonBCastFramesReceivedOKRateread-onlymandatoryThe rate of frames received successfully off of this bus that have a broadcast destination address.
1.3.6.1.4.1.28.10.12.1.11ColumnriLdcBusMonCollisionsread-onlymandatoryThe number of collisions detected on this bus that occurred within 512 bit times from frame start. (Collisions are normal for networks with high utilization.)
1.3.6.1.4.1.28.10.12.1.12ColumnriLdcBusMonCollisionsRateread-onlymandatoryThe rate of collisions detected on this bus that occurred within 512 bit times from frame start.
1.3.6.1.4.1.28.10.12.1.13ColumnriLdcBusMonLateCollisionsread-onlymandatoryThe number of times that a collision has been detected on this bus later than 512 bit times from frame start. A late collision is counted twice, both as a coll…
1.3.6.1.4.1.28.10.12.1.14ColumnriLdcBusMonLateCollisionsRateread-onlymandatoryThe rate of times that a collision has been detected on this bus later than 512 bit times from frame start. A late collision is counted twice, both as a collis…
1.3.6.1.4.1.28.10.12.1.15ColumnriLdcBusMonCRCErrorsread-onlymandatoryThe number of frames received off this bus that are an integral number of octets in length (the number of bits they contain is a multiple of eight) and that do…
1.3.6.1.4.1.28.10.12.1.16ColumnriLdcBusMonCRCErrorsRateread-onlymandatoryThe rate of frames received off this bus that are an integral number of octets in length (i.e., the number of bits they contain is a multiple of eight) and tha…
1.3.6.1.4.1.28.10.12.1.17ColumnriLdcBusMonPygmiesread-onlymandatoryThe number of collision fragments (frames less than 96 bits long) received on this bus.
1.3.6.1.4.1.28.10.12.1.18ColumnriLdcBusMonPygmiesRateread-onlymandatoryThe rate of collision fragments (frames less than 96 bits long) received on this bus.
1.3.6.1.4.1.28.10.12.1.19ColumnriLdcBusMonShortFramesread-onlymandatoryThe number of frames received on this bus that are between 8 and 63 octets long.
1.3.6.1.4.1.28.10.12.1.20ColumnriLdcBusMonShortFramesRateread-onlymandatoryThe rate of frames received on this bus that are between 8 and 63 octets long.
1.3.6.1.4.1.28.10.12.1.21ColumnriLdcBusMonInRangeLengthErrorsread-onlymandatoryNumber of in-range errors received on this bus. IEEE 802.3 frames contain a length field, indicating the length of the frame. If the value in the length field …
1.3.6.1.4.1.28.10.12.1.22ColumnriLdcBusMonInRangeLengthErrorsRateread-onlymandatoryRate of in-range errors received on this bus. IEEE 802.3 frames contain a length field, indicating the length of the frame. If the value in the length field an…
1.3.6.1.4.1.28.10.12.1.23ColumnriLdcBusMonOutOfRangeLengthErrorsread-onlymandatoryNumber of out-of-range errors received on this bus. IEEE 802.3 frames contain a length field, indicating the length of the frame. If the length of the frame is…
1.3.6.1.4.1.28.10.12.1.24ColumnriLdcBusMonOutOfRangeLengthErrorsRateread-onlymandatoryRate of out-of-range errors received on this bus. IEEE 802.3 frames contain a length field, indicating the length of the frame. If the length of the frame is o…
1.3.6.1.4.1.28.10.12.1.25ColumnriLdcBusMonFramesTooLongread-onlymandatoryThe number of frames received on this bus that are greater than 1520 octets long, but not greater than 5msec in duration (which would indicate a jabber conditi…
1.3.6.1.4.1.28.10.12.1.26ColumnriLdcBusMonFramesTooLongRateread-onlymandatoryThe rate of frames received on this bus that are greater than 1520 octets long, but not greater than 5 msec in duration (which would indicate a jabber conditio…
1.3.6.1.4.1.28.10.12.1.27ColumnriLdcBusMonAlignmentErrorsread-onlymandatoryThe number of frames received on this bus that are not an integral number of octets in length (i.e., the number of bits they contain is not a multiple of eight…
1.3.6.1.4.1.28.10.12.1.28ColumnriLdcBusMonAlignmentErrorsRateread-onlymandatoryThe rate of frames received on this bus that are not an integral number of octets in length. (These frames will not pass the FCS check but are not counted as F…
1.3.6.1.4.1.28.10.12.1.29ColumnriLdcBusMonMissedPacketsread-onlymandatoryThe number of frames received while the INX-NMM receive state is disabled. The receive state usually becomes disabled because a network error condition has cre…
1.3.6.1.4.1.28.10.12.1.30ColumnriLdcBusMonMissedPacketsRateread-onlymandatoryThe rate of frames received while the INX-NMM receive state is disabled. The receive state usually becomes disabled because a network error condition has creat…
1.3.6.1.4.1.28.10.12.1.31ColumnriLdcBusMonErrorFramesread-onlymandatoryThe total number of frames received with CRC, alignment, or length errors.
1.3.6.1.4.1.28.10.12.1.32ColumnriLdcBusMonErrorFramesRateread-onlymandatoryThe rate of frames received with CRC, alignment, or length errors.
1.3.6.1.4.1.28.10.12.1.33ColumnriLdcBusMonUtilPeakread-writemandatoryThe highest utilization of the 10MBit/sec Ethernet network detected since NMM boot (eg. 27% Peak Utilization = 2.7Mbits/sec). To clear this value and the UtilP…
1.3.6.1.4.1.28.10.12.1.34ColumnriLdcBusMonUtilPeakTimeread-onlymandatoryThe NMM Uptime when the UtilPeak was detected.
1.3.6.1.4.1.28.10.12.1.35ColumnriLdcBusMonUtilCurrentread-onlymandatoryThe current utilization of the 10MBit/sec Ethernet network. (eg. 15% Current Utilization = 1.5Mbits/sec).
1.3.6.1.4.1.28.10.13TableriLdcFanTablenot-accessiblemandatoryThe Fan Status table lists the status of all fans in the chassis. You cannot access this variable; it is only a table marker in the MIB.
1.3.6.1.4.1.28.10.13.1RowriLdcFanEntrynot-accessiblemandatoryStatus information on a single fan, i.e., an entry in the Fan Status table. (See the previous variable, Fan Status Table, for an explanation of this table.) Yo…
1.3.6.1.4.1.28.10.13.1.1ColumnriLdcFanIndexread-onlymandatoryA unique value for each Fan Status Table entry. The value ranges from 1 to the value of Fan Status Entries. The fans are numbered from left to right as you are…
1.3.6.1.4.1.28.10.13.1.2ColumnriLdcFanStatusread-onlymandatoryThe status of the fan. This variable returns on(82) if the fan is operating, and off(81) if it is not operating.
1.3.6.1.4.1.28.10.14NoderiHotFail
1.3.6.1.4.1.28.10.14.1ScalarriLdcHfAPrimaryAuiread-writemandatoryThe number of the slot in which the primary Bus A backbone connectivity module for the chassis is installed.(CMM Slot is recommended)
1.3.6.1.4.1.28.10.14.2ScalarriLdcHfAPrimaryMediaread-writemandatoryThe media type of the primary Bus A backbone connectivity module for the chassis. This variable returns backbone-thick(11) if the module is configured to be co…
1.3.6.1.4.1.28.10.14.3ScalarriLdcHfBPrimaryAuiread-writemandatoryThe number of the slot in which the primary Bus B backbone connectivity module for the chassis is installed. You can set this variable to not configured(200) i…
1.3.6.1.4.1.28.10.14.4ScalarriLdcHfBPrimaryMediaread-writemandatoryThe media type of the primary Bus B backbone connectivity module for the chassis. This variable returns backbone-thick(11) if the module is configured to be co…
1.3.6.1.4.1.28.10.14.5ScalarriLdcHfABackupAuiread-writemandatoryThe number of the slot in which the backup Bus A backbone connectivity module for the chassis is installed. Note: If you do not want to enable hot failover, bu…
1.3.6.1.4.1.28.10.14.6ScalarriLdcHfABackupMediaread-writemandatoryThe media type of the backup Bus A backbone connectivity module for the chassis. This variable returns backbone-thick(11) if the module is configured to be con…
1.3.6.1.4.1.28.10.14.7ScalarriLdcHfBBackupAuiread-writemandatoryThe number of the slot in which the backup Bus B backbone connectivity module for the chassis is installed. You can set this variable to not-configured(200) if…
1.3.6.1.4.1.28.10.14.8ScalarriLdcHfBBackupMediaread-writemandatoryThe media type of the backup Bus B backbone connectivity module for the chassis. This variable returns backbone-thick(11) if the module is configured to be con…
1.3.6.1.4.1.28.10.14.9ScalarriLdcHfIntStateread-writemandatoryThe current state of internal hot failover detection for both Bus A and Bus B. Setting this variable to enabled(1) invokes internal hot failover detection/moni…
1.3.6.1.4.1.28.10.14.10ScalarriLdcHfIntPollFreqread-writemandatoryThe frequency, in seconds, with which the INX-NMM master and slave modules attempt to transmit a self-addressed packet onto the bus for which their NIC is conf…
1.3.6.1.4.1.28.10.14.11ScalarriLdcHfIntRetriesread-writemandatoryThe number of polling transmits (see the previous variable, Internal Polling Frequency) that must fail before internal failover is invoked. The range of valid …
1.3.6.1.4.1.28.10.14.12ScalarriLdcHfExtStateread-writemandatoryThe current state of external hot failover detection. External hot failover detection is only available for the bus on which the master INX-NMM's NIC is config…
1.3.6.1.4.1.28.10.14.13ScalarriLdcHfExtPing1read-writemandatoryThe IP adress of the node to which the master INX-NMM will ping to detect external cable failures. The master INX-NMM wil send the pings on the bus for which i…
1.3.6.1.4.1.28.10.14.14ScalarriLdcHfExtPing2read-writemandatoryThe IP address of a second node to ping should the first host not respond (see the previous variable, Ext Failover Detection/Ping 1). This eliminates the false…
1.3.6.1.4.1.28.10.14.15ScalarriLdcHfExtPollFreqread-writemandatoryThe frequency, in seconds, with which the master INX-NMM pings the address specified by Ext Failover Detection/Ping 1 or Ext Failover Detection/Ping 2. The ran…
1.3.6.1.4.1.28.10.14.16ScalarriLdcHfExtResponseTmoread-writemandatoryThe number of seconds the INX-NMM waits for a response to the ping before the ping is considered failed. The range of valid values is 1 - 60 seconds, and the d…
1.3.6.1.4.1.28.10.14.17ScalarriLdcHfExtRetriesread-writemandatoryThe number of pings to the host specified by Ext Failover Detection/Ping 1 that must fail before external failover is invoked. The range is 1 - 255, and the de…
1.3.6.1.4.1.28.10.14.18ScalarriLdcHfHysteresisread-writemandatoryThe number of seconds required between failovers from the backup configuration to the primary configuration. This hysteresis time eliminates the continuous hot…
1.3.6.1.4.1.28.10.14.19TableriLdcHfTablenot-accessiblemandatoryThe Hot Failover Status table contains information on the hot failover status of each internal bus.
1.3.6.1.4.1.28.10.14.19.1RowriLdcHfEntrynot-accessiblemandatoryStatistical information for the Hot Failover functions. (See the previous variable, Hot Fail Table, for an explanation of this table.) Hot Failover Status Inde…
1.3.6.1.4.1.28.10.14.19.1.1ColumnriLdcHfIndexread-onlymandatoryA unique value for each bus entry in the Hot Failover Status table, i.e., Bus A or Bus B. This variable returns 1 for Bus A and 2 for Bus B.
1.3.6.1.4.1.28.10.14.19.1.2ColumnriLdcHfPrimBkupStateread-onlymandatoryWhether this bus is currently operating with its primary configuration or its backup configuration. The returned value of this variable depends on the settings…
1.3.6.1.4.1.28.10.14.19.1.3ColumnriLdcHfLastFailoverread-onlymandatoryThe value of INX-NMM Up Time (the sysUpTime variable in the System group for the INX-NMM) at the time the last failover for this bus occurred. By subtracting t…
1.3.6.1.4.1.28.10.14.19.1.4ColumnriLdcHfIntFailoversread-onlymandatoryThe number of internal hot failovers invoked for this bus since the last boot of the INX-NMM.
1.3.6.1.4.1.28.10.14.19.1.5ColumnriLdcHfExtFailoversread-onlymandatoryThe number of external hot failovers invoked for this bus since the last boot of the INX-NMM.
1.3.6.1.4.1.28.10.14.19.1.6ColumnriLdcHfPrimReasonread-onlymandatoryThe reason that an initial failover or automatic configuration change was invoked following a fault detected in the primary configuration. This variable return…
1.3.6.1.4.1.28.10.14.19.1.7ColumnriLdcHfBkupReasonread-onlymandatoryThe reason that an initial failover or automatic Bacbone re-configuration was invoked following a fault detected in the backup configuration. This variable ret…
1.3.6.1.4.1.28.10.14.19.1.8ColumnriLdcHfIntTxStatusread-onlymandatoryThis variable returns the transmit status of the internal detection scheme for this bus. It returns internal-bus-OK(1) if internal transmits are succeeding and…
1.3.6.1.4.1.28.10.14.19.1.9ColumnriLdcHfIntTxFailuresread-onlymandatoryThe number of internal transmit failures that have occurred on this bus since the last boot of the INX-NMM.
1.3.6.1.4.1.28.10.14.19.1.10ColumnriLdcHfAutopartStateread-onlymandatoryThe state of the backbone connectivity module for this bus, i.e., whether it is currently autopartitioned. This variable returns aui-OK(1) if the module is not…
1.3.6.1.4.1.28.10.14.19.1.11ColumnriLdcHfBusAutopartitionsread-onlymandatoryThe number of times this bus has autopartitioned since the last boot of the INX-NMM. This count is the number of autopartitions of the backbone connectivity mo…
1.3.6.1.4.1.28.10.14.19.1.12ColumnriLdcHfBusClockStatusread-onlymandatoryThe status of this bus's master clock, which is provided by the backbone connectivity module. This variable returns busclockok(1) if the clock is functioning n…
1.3.6.1.4.1.28.10.14.19.1.13ColumnriLdcHfBusClockFailuresread-onlymandatoryThe number times this bus's clock has failed since the last reboot of the INX-NMM.
1.3.6.1.4.1.28.10.14.19.1.14ColumnriLdcHfBusConfigStatusread-onlymandatoryThe current status of the backbone connectivity module's configuration.
1.3.6.1.4.1.28.10.14.19.1.15ColumnriLdcHfBusConfigChangesread-onlymandatoryThe number of times the backbone modules were reconfigured to the primary configuration because a mismatch of that configuration with the actual physical backb…
1.3.6.1.4.1.28.10.14.19.1.16ColumnriLdcHfExtPing1Statusread-onlymandatoryThe ping 1 host (i.e., the value of Ext Failover Det'n/Ping 1 Addr) status for the external detection scheme. This variable returns external-bus-OK(1) if the I…
1.3.6.1.4.1.28.10.14.19.1.17ColumnriLdcHfExtPing1Failuresread-onlymandatoryThe number of ping 1 host (i.e.,the value of Ext Failover Det'n/Ping 1 Addr) status failures for the external detection scheme since the last boot of the INX-N…
1.3.6.1.4.1.28.10.14.19.1.18ColumnriLdcHfExtPing2Statusread-onlymandatoryThe ping 2 host (i.e., the value of Ext Failover Det'n/Ping 2 Addr) status for the external detection scheme. This variable returns external-bus-OK(1) if the I…
1.3.6.1.4.1.28.10.14.19.1.19ColumnriLdcHfExtPing2Failuresread-onlymandatoryThe number of ping 2 (i.e., the value of Ext Failover Det'n/Ping 2 Addr) host status failures for the external detection scheme since the last boot of the INX-…
1.3.6.1.4.1.28.13NoderiPort
1.3.6.1.4.1.28.13.1TableriPortTablenot-accessiblemandatoryStatistical information about the INX-10BT and INX-FOIRL module ports. You cannot access this variable; it is only a table marker in the MIB. Note: If there is…
1.3.6.1.4.1.28.13.1.1RowriPortEntrynot-accessiblemandatoryStatistical information for a single Ethernet port, i.e., an entry in the Port table. (See the previous variable, Port Table, for an explanation of this table.…
1.3.6.1.4.1.28.13.1.1.1ColumnriPortSlotNumberread-onlymandatoryA unique value for each slot in the chassis that contains an INX-10BT or INX-FOIRL module. Values range from 1 to n, where n is the maximum number of INX-10BT …
1.3.6.1.4.1.28.13.1.1.2ColumnriPortPortNumberread-onlymandatoryA unique value for each port on the INX-10BT or INX-FOIRL module that contains this port. The value ranges from 1 to n, where n is the total number of ports on…
1.3.6.1.4.1.28.13.1.1.3ColumnriPortStateread-writemandatoryThe state of the port. o empty(41) indicates that there is nothing in the slot. You cannot set the variable to this value o auto-partitioned(3) indicates that …
1.3.6.1.4.1.28.13.1.1.4ColumnriPortFramesReceivedOKread-onlymandatoryThe number of frames successfully received through this port. This count does not include frames received with FCS, length, or alignment errors, or frames lost…
1.3.6.1.4.1.28.13.1.1.5ColumnriPortFramesReceivedOKRateread-onlymandatoryThe rate of frames/sec that have been successfully received through this port. This count does not include frames received with FCS, length, or alignment error…
1.3.6.1.4.1.28.13.1.1.6ColumnriPortOctetsReceivedOKread-onlymandatoryThe number of octets associated with the frames included in Frames Received.
1.3.6.1.4.1.28.13.1.1.7ColumnriPortOctetsReceivedOKRateread-onlymandatoryThe rate of octets/sec associated with the frames included in Frames Received.
1.3.6.1.4.1.28.13.1.1.8ColumnriPortMulticastFramesReceivedOKread-onlymandatoryThe number of frames that had a multicast destination address sent by the device attached to this port.
1.3.6.1.4.1.28.13.1.1.9ColumnriPortMulticastFramesReceivedOKRateread-onlymandatoryThe rate of frames/sec sent by the device attached to this port that had a multicast destination address.
1.3.6.1.4.1.28.13.1.1.10ColumnriPortBroadcastFramesReceivedOKread-onlymandatoryThe number of frames that had a broadcast destination address sent by the device attached to this port.
1.3.6.1.4.1.28.13.1.1.11ColumnriPortBroadcastFramesReceivedOKRateread-onlymandatoryThe rate of frames/sec sent by the device attached to this port that had a broadcast destination address.
1.3.6.1.4.1.28.13.1.1.12ColumnriPortCollisionsread-onlymandatoryThe number of collisions within 512 bit times from frame start detected when the device attached to this port attempted to transmit. (Collisions are normal for…
1.3.6.1.4.1.28.13.1.1.13ColumnriPortCollisionsRateread-onlymandatoryThe rate of collisions/sec within 512 bit times from frame start detected when the device attached to this port attempted to transmit.
1.3.6.1.4.1.28.13.1.1.14ColumnriPortCRCErrorsread-onlymandatoryThe number of frames sent by the device attached to this port that are an integral number of octets in length (i.e., the number of bits they contain is a multi…
1.3.6.1.4.1.28.13.1.1.15ColumnriPortCRCErrorsRateread-onlymandatoryThe rate of frames/sec sent by the device attached to this port that are an integral number of octets in length and do not pass the FCS check.
1.3.6.1.4.1.28.13.1.1.16ColumnriPortShortFramesread-onlymandatoryThe number of frames sent by the device attached to this port that are 8-63 octets long.
1.3.6.1.4.1.28.13.1.1.17ColumnriPortShortFramesRateread-onlymandatoryThe rate of frames/sec sent by the device attached to this port that are 8-63 octets long.
1.3.6.1.4.1.28.13.1.1.18ColumnriPortInRangeLengthErrorsread-onlymandatoryThe number of in-range errors sent by the device attached to this port. IEEE 802.3 frames contain a length field, indicating the length of the frame. If the va…
1.3.6.1.4.1.28.13.1.1.19ColumnriPortInRangeLengthErrorsRateread-onlymandatoryThe rate of in-range errors sent by the device attached to this port. IEEE 802.3 frames contain a length field, indicating the length of the frame. If the valu…
1.3.6.1.4.1.28.13.1.1.20ColumnriPortOutOfRangeLengthErrorsread-onlymandatoryThe number of out-of-range errors sent by the device attached to this port. IEEE 802.3 frames contain a length field, indicating the length of the frame. If th…
1.3.6.1.4.1.28.13.1.1.21ColumnriPortOutOfRangeLengthErrorsRateread-onlymandatoryThe rate of out-of-range errors sent by the device attached to this port. IEEE 802.3 frames contain a length field, indicating the length of the frame. If the …
1.3.6.1.4.1.28.13.1.1.22ColumnriPortFramesTooLongread-onlymandatoryThe number of frames sent by the device attached to this port that were greater than 1520 octets long, but not greater than 5 msec in duration (which would ind…
1.3.6.1.4.1.28.13.1.1.23ColumnriPortFramesTooLongRateread-onlymandatoryThe rate of frames/sec sent by the device attached to this port that were greater than 1520 octets long, but not greater than 5 msec in duration (which would i…
1.3.6.1.4.1.28.13.1.1.24ColumnriPortAlignmentErrorsread-onlymandatoryThe number of frames sent by the device attached to this port that were not an integral number of octets in length (i.e., the number of bits they contain is no…
1.3.6.1.4.1.28.13.1.1.25ColumnriPortAlignmentErrorsRateread-onlymandatoryThe rate of frames/sec sent by the device attached to this port that were not an integral number of octets in length. (These frames will not pass the FCS check…
1.3.6.1.4.1.28.13.1.1.26ColumnriPortAutoPartitionsread-onlymandatoryThe number of times that the port was automatically partitioned from the network because of an error detected by the INX-10BT or INX-FOIRL module. Autopartitio…
1.3.6.1.4.1.28.13.1.1.27ColumnriPortAutoPartitionsRateread-onlymandatoryThe rate of times/sec that the port was automatically partitioned from the network because of an error detected by the INX-10BT or INX-FOIRL module.
1.3.6.1.4.1.28.13.1.1.28ColumnriPortTransmitClockViolationsread-onlymandatoryThe number of times that the device attached to the port transmits, but its frame cannot be decoded by the module because of a timing error. The timing error i…
1.3.6.1.4.1.28.13.1.1.29ColumnriPortTransmitClockViolationsRateread-onlymandatoryThe rate of times/sec that the device attached to the port transmits, but its frame cannot be decoded by the module because of a timing error. The timing error…
1.3.6.1.4.1.28.13.1.1.30ColumnriPortLastSourceAddressread-onlymandatoryThe Ethernet source address of the last uncorrupted frame sent by the device attached to this port.
1.3.6.1.4.1.28.13.1.1.31ColumnriPortSourceAddressChangesread-onlymandatoryThe number of times the Ethernet source address of a frame transmitted by the device attached to the port has changed from one frame to the next frame. If the …
1.3.6.1.4.1.28.13.1.1.32ColumnriPortSourceAddressChangesRateread-onlymandatoryThe rate of times/sec the Ethernet source address of a frame transmitted by the device attached to the port has changed from one frame to the next frame.
1.3.6.1.4.1.28.13.1.1.33ColumnriPortLinkIntegrityChangesread-onlymandatoryThe total number of times the device attached to the port has been disconnected or reconnected. When an INX-10BT or INX-FOIRL module is booted, it has a link i…
1.3.6.1.4.1.28.13.1.1.34ColumnriPortLinkIntegrityChangesRateread-onlymandatoryThe rate of times the device attached to the port has been disconnected or reconnected. When an INX-10BT or INX-FOIRL module is booted, it has a link integrity…
1.3.6.1.4.1.28.13.1.1.35ColumnriPortLateCollisionsread-onlymandatoryThe number of times that a collision has been detected on this port later than 512 bit times from frame start. A late collision is counted twice, as both a col…
1.3.6.1.4.1.28.13.1.1.36ColumnriPortLateCollisionsRateread-onlymandatoryThe rate of the times/sec that a collision has been detected on this port later than 512 bit times from frame start. A late collision is counted twice, as both…
1.3.6.1.4.1.28.13.1.1.37ColumnriPortMauJabberLockupsread-onlymandatoryThe number of times the port detects that the attached device is transmitting continuously for more than six ms.
1.3.6.1.4.1.28.13.1.1.38ColumnriPortMauJabberpLockupsRateread-onlymandatoryThe rate of times/sec the port detects that the attached device is transmitting for more than 6 ms.
1.3.6.1.4.1.28.13.1.1.39ColumnriPortLinkStatusread-onlymandatoryWhether an active device is attached to this port. The device's MAU should generate a 100-ns pulse every 8 to 16 msec. This pulse is detected by the INX-10BT o…
1.3.6.1.4.1.28.16NoderiBoot
1.3.6.1.4.1.28.16.1ScalarriNumBootsread-writemandatoryThe number of entries in the Boot table. There is one entry for the INX-NMM's operating software image file, and one entry for the Chassis Management Protocol …
1.3.6.1.4.1.28.16.2ScalarriBootServiceOfferedread-writemandatoryThe setting of this variable determines whether this INX-NMM can provide boot operating system images to other INX-NMM, returning true(2) if it can and false(1…
1.3.6.1.4.1.28.16.3TableriBootTablenot-accessiblemandatoryThe Boot table contains boot information. You cannot access this variable; it is only a table marker in the MIB.
1.3.6.1.4.1.28.16.3.1RowriBootEntrynot-accessiblemandatoryThis variable returns a particular boot specification, i.e., an entry in the Boot table. (See the previous variable, Boot Table, for an explanation of this tab…
1.3.6.1.4.1.28.16.3.1.1ColumnriBootIndexread-onlymandatoryThis variable returns a unique value for each entry in the Boot table. It returns 1 for the Chassis Management Protocol file and 2 for the operating software i…
1.3.6.1.4.1.28.16.3.1.3ColumnriBootFileNameread-writemandatoryThe name of the operating software image file on the Featurecard or TFTP boot server from which you want to load the image.
1.3.6.1.4.1.28.16.3.1.6ColumnriBootIPAddressread-writemandatoryThe Internet address of the boot server from which you want to load the software to the INX-NMM. Note: There is only one boot server IP address for all entries…
1.3.6.1.4.1.28.16.3.1.7ColumnriBootVersionread-writemandatoryThe revision level of the operating software image file on the Featurecard or TFTP boot server from which you want to load the image.
1.3.6.1.4.1.28.16.3.1.8ColumnriBootGatewayread-writemandatoryThe Internet address of the gateway the INX-NMM must use to get to the boot server, if applicable. Note: There is only one gateway address for all entries in t…
1.3.6.1.4.1.28.17NoderiThresh
1.3.6.1.4.1.28.17.1ScalarriThCountread-onlymandatorythe number of active entries in the threshold table.
1.3.6.1.4.1.28.17.2ScalarriThMaxCountread-onlymandatoryThe maximum number of active thresholds allowed.
1.3.6.1.4.1.28.17.3ScalarriThUniqueIndexread-writemandatorySetting this variable creates a new entry in the Threshold table. You must type a number for the entry when you set this variable, but the INX-NMM assigns the …
1.3.6.1.4.1.28.17.4ScalarriThIntervalread-writemandatoryHow often, in seconds, thresholds exceeded are checked. To disable threshold checking, set this variable to 0.
1.3.6.1.4.1.28.17.5TableriThTablenot-accessiblemandatoryA table containing information about the thresholds that have been set. You cannot access this variable; it is only a table marker in the MIB.
1.3.6.1.4.1.28.17.5.1RowriThEntrynot-accessiblemandatoryAn entry in the Threshold table. (See the previous variable, Threshold Table, for an explanation of this table). You cannot access this variable; it is only a …
1.3.6.1.4.1.28.17.5.1.1ColumnriThIndexread-onlymandatoryA unique value for each threshold.
1.3.6.1.4.1.28.17.5.1.2ColumnriThStatusread-writemandatoryThe current status of the threshold. o delete(1) deletes the threshold entry specified. o unset(2) means that the threshold is newly created, currently being c…
1.3.6.1.4.1.28.17.5.1.3ColumnriThObjectread-writemandatoryThe complete object identifier of the variable on which this threshold is set. Threshold Object ID can be set only for Counter or Gauge variables. If you attem…
1.3.6.1.4.1.28.17.5.1.4ColumnriThThresholdread-writemandatoryThe threshold value for the variable identified by Threshold Object ID. If this particular variable is a gauge, then whenever its value rises above or drops be…
1.3.6.1.4.1.28.17.5.1.5ColumnriThHysteresisread-writemandatoryThe hysteresis value for the threshold. After a variable's threshold is triggered, the value of the variable must either drop below or rise above a certain val…
1.3.6.1.4.1.28.17.5.1.6ColumnriThDirectionread-writemandatoryThe direction in which a change in a Gauge variable's value causes a threshold to trigger. If its direction is up, a trigger occurs when the variable's value r…
1.3.6.1.4.1.28.17.5.1.7ColumnriThTriggeredCountread-onlymandatoryThe number of times that this threshold has been triggered.
1.3.6.1.4.1.28.17.5.1.8ColumnriThCommunityread-writemandatoryThe community name to place in the authentication header of the trap PDU. This variable specifies the community to which the trap is to be sent when a threshol…
1.3.6.1.4.1.28.17.5.1.9ColumnriThPhysDestinationread-writemandatoryThe Ethernet address of the node to which the trap is to be sent when the threshold is triggered.
1.3.6.1.4.1.28.17.5.1.10ColumnriThIPDestinationread-writemandatoryThe IP address of the node to which the trap is to be sent when the threshold is triggered.
1.3.6.1.4.1.28.18NoderiSystem
1.3.6.1.4.1.28.18.1ScalarriSystemHardwareRevread-onlymandatoryThe hardware revision level of the INX-NMM.
1.3.6.1.4.1.28.18.2ScalarriSystemFirmwareRevread-onlymandatoryThe firmware revision level of the INX-NMM.
1.3.6.1.4.1.28.18.3ScalarriSystemSoftwareRevread-onlymandatoryThe software revision level of the INX-NMM.
1.3.6.1.4.1.28.18.4ScalarriSystemSerialNumberread-onlymandatoryThe serial number of the INX-NMM.
1.3.6.1.4.1.28.18.5ScalarriSystemResetread-writemandatoryThe reset status of the INX-NMM. The reset types are o resetupdate(3) saves the current configuration in NVRAM and then resets the INX-NMM. This value is retur…
1.3.6.1.4.1.28.18.12ScalarriSystemTicksPerSecondread-onlymandatoryThe number of internal clock ticks that occur each second on the INX-NMM, which is 100.
1.3.6.1.4.1.28.18.13ScalarriSystemRateIntervalread-writemandatoryHow often, in seconds, any rate statistic maintained by the INX-NMM is checked. The default is 20 seconds.
1.3.6.1.4.1.28.18.15ScalarriSystemNVRamWriteCountread-onlymandatoryThe number of times that the NVRAM has been changed.
1.3.6.1.4.1.28.22NoderiTsRates
1.3.6.1.4.1.28.22.1ScalarriRateTxSingleCollisionFramesread-onlymandatoryThe rate of frames that were successfully transmitted after experiencing one and only one collision. This variable corresponds to the Single Collisions Transmi…
1.3.6.1.4.1.28.22.2ScalarriRateTxMultipleCollisionFramesread-onlymandatoryThe rate of frames that were successfully transmitted after experiencing more than one collision. This variable corresponds to the Multiple Collisions Xmitted …
1.3.6.1.4.1.28.22.3ScalarriRateTxDeferredTransmissionsread-onlymandatoryThe rate of times the INX-NMM deferred transmission of data because it sensed traffic on the network. Because the INX-NMM does not record deferrals, this varia…
1.3.6.1.4.1.28.22.4ScalarriRateTxLateCollisionsread-onlymandatoryThe rate of times that a collision has been detected on this bus later than 512 bit times from frame start. This count is not maintained by the INX-NMM, so thi…
1.3.6.1.4.1.28.22.5ScalarriRateTxInternalMACTransmitErrorsread-onlymandatoryThe rate of frames the interface could not transmit because of an internal MAC sublayer transmit error. This variable corresponds to the MAC Transmit Errors va…
1.3.6.1.4.1.28.22.6ScalarriRateTxCarrierSenseErrorsread-onlymandatoryThe rate of times that the carrier-sense condition was lost or never asserted when the INX-NMM attempted to transmit a frame on the interface. This variable co…
1.3.6.1.4.1.28.22.7ScalarriRateTxExcessiveDeferralsread-onlymandatoryThe rate of frames the INX-NMM deferred transmitting for an excessive period of time. Because the INX-NMM interface does not record deferrals, this variable al…
1.3.6.1.4.1.28.22.8ScalarriRateRxInternalMACReceiveErrorsread-onlymandatoryThe rate of frames the interface could not receive because of an internal MAC sublayer receive error. This variable corresponds to the MAC Errors Received vari…
1.3.6.1.4.1.28.22.9ScalarriRateRxFCSErrorsread-onlymandatoryThe rate of frames received on the interface that are an integral number of octets in length (i.e., the number of bits they contain is a multiple of eight) tha…
1.3.6.1.4.1.28.22.10ScalarriRateRxAlignmentErrorsread-onlymandatoryThe rate of frames received on the interface that are not an integral number of octets in length (i.e., the number of bits they contain is not a multiple of ei…
1.3.6.1.4.1.28.22.11ScalarriRateRxInRangeLengthErrorsread-onlymandatoryThe rate of in-range length errors received. IEEE 802.3 frames contain a length field, indicating the length of the frame. If the value in the length field and…
1.3.6.1.4.1.28.22.12ScalarriRateRxOutofRangeLengthFieldsread-onlymandatoryThe rate of out-of-range length errors received. IEEE 802.3 frames contain a length field, indicating the length of the frame. If the length of the frame is ou…
1.3.6.1.4.1.28.22.13ScalarriRateRxFrameTooLongsread-onlymandatoryThe rate of frames received on the interface that exceed the maximum permitted frame size, i.e., 1012 octets. This variable corresponds to the Too Long Frames …