This MIB is to be used to provide monitoring information support for Lenovo XClarity Controller (XCC)
OIDNameAccessStatusDescription
1.3.6.1.4.1.19046.11.1IdentitylenovoXCCMIBThis MIB is to be used to provide monitoring information support for Lenovo XClarity Controller (XCC)
1.3.6.1.4.1.19046.11.1.1Nodemonitors
1.3.6.1.4.1.19046.11.1.1.1Nodetemperature
1.3.6.1.4.1.19046.11.1.1.1.1ScalartempNumberread-onlymandatoryThe present number of rows in the temperature table.
1.3.6.1.4.1.19046.11.1.1.1.2TabletempTablenot-accessiblemandatoryThis table contains temperature measurement information.
1.3.6.1.4.1.19046.11.1.1.1.2.1RowtempEntrynot-accessiblemandatoryEach row contains parameters related to a temperature measurement channel.
1.3.6.1.4.1.19046.11.1.1.1.2.1.1ColumntempIndexread-onlymandatoryThis column is used to identify a particular temperature measurement channel.
1.3.6.1.4.1.19046.11.1.1.1.2.1.2ColumntempDescrread-onlymandatoryA description of the temperature measurement channel.
1.3.6.1.4.1.19046.11.1.1.1.2.1.3ColumntempReadingread-onlymandatoryThe measured temperature.
1.3.6.1.4.1.19046.11.1.1.1.2.1.4ColumntempNominalReadingread-onlymandatoryThe nominal temperature, if available.
1.3.6.1.4.1.19046.11.1.1.1.2.1.5ColumntempNonRecovLimitHighread-onlymandatoryThe non-recoverable limit for the measured temperature. If the measured value rises above this limit a trap is sent.
1.3.6.1.4.1.19046.11.1.1.1.2.1.6ColumntempCritLimitHighread-onlymandatoryThe critical limit for the measured temperature. If the measured value rises above this limit a trap is sent.
1.3.6.1.4.1.19046.11.1.1.1.2.1.7ColumntempNonCritLimitHighread-onlymandatoryThe non-critical limit for the measured temperature. If the measured value rises above this limit a trap is sent.
1.3.6.1.4.1.19046.11.1.1.1.2.1.8ColumntempNonRecovLimitLowread-onlymandatoryThe non-recoverable limit for the measured temperature. If the measured value falls below this limit a trap is sent.
1.3.6.1.4.1.19046.11.1.1.1.2.1.9ColumntempCritLimitLowread-onlymandatoryThe critical limit for the measured temperature. If the measured value falls below this limit a trap is sent.
1.3.6.1.4.1.19046.11.1.1.1.2.1.10ColumntempNonCritLimitLowread-onlymandatoryThe non-critical limit for the measured temperature. If the measured value falls below this limit a trap is sent.
1.3.6.1.4.1.19046.11.1.1.1.2.1.11ColumntempHealthStatusread-onlymandatoryA description of the temperature component status.
1.3.6.1.4.1.19046.11.1.1.2Nodevoltage
1.3.6.1.4.1.19046.11.1.1.2.1ScalarvoltNumberread-onlymandatoryThe present number of rows in the voltage table.
1.3.6.1.4.1.19046.11.1.1.2.2TablevoltTablenot-accessiblemandatoryThis table contains voltage measurement information.
1.3.6.1.4.1.19046.11.1.1.2.2.1RowvoltEntrynot-accessiblemandatoryEach row contains parameters related to a voltage measurement channel.
1.3.6.1.4.1.19046.11.1.1.2.2.1.1ColumnvoltIndexread-onlymandatoryThis column is used to identify a particular voltage measurement channel.
1.3.6.1.4.1.19046.11.1.1.2.2.1.2ColumnvoltDescrread-onlymandatoryA description of the voltage measurement channel.
1.3.6.1.4.1.19046.11.1.1.2.2.1.3ColumnvoltReadingread-onlymandatoryThe measured voltage.
1.3.6.1.4.1.19046.11.1.1.2.2.1.4ColumnvoltNominalReadingread-onlymandatoryThe nominal voltage, if available.
1.3.6.1.4.1.19046.11.1.1.2.2.1.5ColumnvoltNonRecovLimitHighread-onlymandatoryThe high non-recoverable limit for the measured voltage. If the measured value falls above this limit a trap is sent.
1.3.6.1.4.1.19046.11.1.1.2.2.1.6ColumnvoltCritLimitHighread-onlymandatoryThe high critical limit for the measured voltage. If the measured value rises above this limit a trap is sent.
1.3.6.1.4.1.19046.11.1.1.2.2.1.7ColumnvoltNonCritLimitHighread-onlymandatoryThe high non-critical limit for the measured voltage. If the measured value rises above this limit a trap is sent.
1.3.6.1.4.1.19046.11.1.1.2.2.1.8ColumnvoltNonRecovLimitLowread-onlymandatoryThe low non-recoverable limit for the measured voltage. If the measured value falls below this limit a trap is sent.
1.3.6.1.4.1.19046.11.1.1.2.2.1.9ColumnvoltCritLimitLowread-onlymandatoryThe low critical limit for the measured voltage. If the measured value falls below this limit a trap is sent.
1.3.6.1.4.1.19046.11.1.1.2.2.1.10ColumnvoltNonCritLimitLowread-onlymandatoryThe low non-critical limit for the measured voltage. If the measured value falls below this limit a trap is sent.
1.3.6.1.4.1.19046.11.1.1.2.2.1.11ColumnvoltHealthStatusread-onlymandatoryA description of the voltage component status.
1.3.6.1.4.1.19046.11.1.1.3Nodefans
1.3.6.1.4.1.19046.11.1.1.3.1ScalarfanNumberread-onlymandatoryThe present number of rows in the fan table.
1.3.6.1.4.1.19046.11.1.1.3.2TablefanTablenot-accessiblemandatoryThis table contains fan information.
1.3.6.1.4.1.19046.11.1.1.3.2.1RowfanEntrynot-accessiblemandatoryEach row contains parameters related to a fan.
1.3.6.1.4.1.19046.11.1.1.3.2.1.1ColumnfanIndexread-onlymandatoryThis column is used to identify a particular fan.
1.3.6.1.4.1.19046.11.1.1.3.2.1.2ColumnfanDescrread-onlymandatoryA description of the fan measurement channel.
1.3.6.1.4.1.19046.11.1.1.3.2.1.3ColumnfanSpeedread-onlymandatoryFan speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leading zero.…
1.3.6.1.4.1.19046.11.1.1.3.2.1.4ColumnfanNonRecovLimitHighread-onlymandatoryThe high non-recoverable limit for the measured fan. If the measured value falls above this limit a trap is sent.
1.3.6.1.4.1.19046.11.1.1.3.2.1.5ColumnfanCritLimitHighread-onlymandatoryThe high critical limit for the measured fan. If the measured value rises above this limit a trap is sent.
1.3.6.1.4.1.19046.11.1.1.3.2.1.6ColumnfanNonCritLimitHighread-onlymandatoryThe high non-critical limit for the measured fan. If the measured value rises above this limit a trap is sent.
1.3.6.1.4.1.19046.11.1.1.3.2.1.7ColumnfanNonRecovLimitLowread-onlymandatoryThe low non-recoverable limit for the measured fan. If the measured value falls below this limit a trap is sent.
1.3.6.1.4.1.19046.11.1.1.3.2.1.8ColumnfanCritLimitLowread-onlymandatoryThe low critical limit for the measured fan. If the measured value falls below this limit a trap is sent.
1.3.6.1.4.1.19046.11.1.1.3.2.1.9ColumnfanNonCritLimitLowread-onlymandatoryThe low non-critical limit for the measured fan. If the measured value falls below this limit a trap is sent.
1.3.6.1.4.1.19046.11.1.1.3.2.1.10ColumnfanHealthStatusread-onlymandatoryA description of the fan component status.
1.3.6.1.4.1.19046.11.1.1.4NodesystemHealth
1.3.6.1.4.1.19046.11.1.1.4.1ScalarsystemHealthStatread-onlymandatoryIndicates status of system health for the system in which the XCC resides. Value of 'nonRecoverable' indicates a severe error has occurred and the system may n…
1.3.6.1.4.1.19046.11.1.1.4.2TablesystemHealthSummaryTablenot-accessiblemandatoryTable of System Health summary. Contains more detailed information about the reasons for the overall system health status.
1.3.6.1.4.1.19046.11.1.1.4.2.1RowsystemHealthSummaryEntrynot-accessiblemandatorySystem Health Summary entry
1.3.6.1.4.1.19046.11.1.1.4.2.1.1ColumnsystemHealthSummaryIndexread-onlymandatorySystem health summary index.
1.3.6.1.4.1.19046.11.1.1.4.2.1.2ColumnsystemHealthSummarySeverityread-onlymandatorySystem health summary severity.
1.3.6.1.4.1.19046.11.1.1.4.2.1.3ColumnsystemHealthSummaryDescriptionread-onlymandatorySystem health summary description.
1.3.6.1.4.1.19046.11.1.1.5NodevpdInformation
1.3.6.1.4.1.19046.11.1.1.5.1TablexccVpdTablenot-accessiblemandatoryTable of XCC VPD.
1.3.6.1.4.1.19046.11.1.1.5.1.1RowxccVpdEntrynot-accessiblemandatoryiMBC VPD entry.
1.3.6.1.4.1.19046.11.1.1.5.1.1.1ColumnxccVpdIndexread-onlymandatoryXCC VPD index.
1.3.6.1.4.1.19046.11.1.1.5.1.1.2ColumnxccVpdTyperead-onlymandatoryXCC VPD Type. Indicates either Bios or Diag or spFimware VPD
1.3.6.1.4.1.19046.11.1.1.5.1.1.3ColumnxccVpdVersionStringread-onlymandatoryXCC VPD Version Number of the software(Bios/Diag/spFirmware). For XCC the string contains both the Build ID and the Version Number, for example, like '1AOO3A v…
1.3.6.1.4.1.19046.11.1.1.5.1.1.4ColumnxccVpdReleaseDateread-onlymandatoryXCC VPD Release Date of when the software(Bios/Diag/spFirmware) was released.
1.3.6.1.4.1.19046.11.1.1.5.2NodemachineVpd
1.3.6.1.4.1.19046.11.1.1.5.2.1NodemachineLevelVpd
1.3.6.1.4.1.19046.11.1.1.5.2.1.1ScalarmachineLevelVpdMachineTyperead-onlymandatoryMachine type VPD information.
1.3.6.1.4.1.19046.11.1.1.5.2.1.2ScalarmachineLevelVpdMachineModelread-onlymandatoryMachine model VPD information.
1.3.6.1.4.1.19046.11.1.1.5.2.1.3ScalarmachineLevelSerialNumberread-onlymandatoryMachine serial number VPD information.
1.3.6.1.4.1.19046.11.1.1.5.2.1.4ScalarmachineLevelUUIDread-onlymandatoryMachine UUID(Universal Unique ID information).
1.3.6.1.4.1.19046.11.1.1.5.2.1.5ScalarmachineLevelProductNameread-onlymandatoryMachine Product Name (e.g. System x3650 M2).
1.3.6.1.4.1.19046.11.1.1.5.17TablesystemComponentLevelVpdTablenot-accessiblemandatoryTable of the system component hardware VPD information. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.17.1RowsystemComponentLevelVpdEntrynot-accessiblemandatorySystem component hardware VPD entry. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.17.1.1ColumncomponentLevelVpdIndexread-onlymandatorySystem component level VPD index. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.17.1.2ColumncomponentLevelVpdFruNumberread-onlymandatorySystem component level VPD FRU number. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.17.1.3ColumncomponentLevelVpdFruNameread-onlymandatorySystem component level VPD FRU name. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.17.1.4ColumncomponentLevelVpdSerialNumberread-onlymandatorySystem component level VPD serial number. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.17.1.5ColumncomponentLevelVpdManufacturingIdread-onlymandatorySystem component level VPD manufacturing ID. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.18TablesystemComponentLevelVpdTrackingTablenot-accessiblemandatoryTable of system component hardware VPD tracking activity log. The activity log types depend on ipmifru information in the server but exclude DIMM infromation. …
1.3.6.1.4.1.19046.11.1.1.5.18.1RowsystemComponentLevelVpdTrackingEntrynot-accessiblemandatorySystem component hardware VPD tracking activity log entry. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.18.1.1ColumncomponentLevelVpdTrackingIndexread-onlymandatorySystem component level VPD tracking activity log index. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.18.1.2ColumncomponentLevelVpdTrackingFruNumberread-onlymandatorySystem component level VPD tracking activity log FRU number. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.18.1.3ColumncomponentLevelVpdTrackingFruNameread-onlymandatorySystem component level VPD tracking activity log FRU name. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.18.1.4ColumncomponentLevelVpdTrackingSerialNumberread-onlymandatorySystem component level VPD tracking activity log serial number. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.18.1.5ColumncomponentLevelVpdTrackingManufacturingIdread-onlymandatorySystem component level VPD tracking activity log manufacturing ID. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.18.1.6ColumncomponentLevelVpdTrackingActionread-onlymandatorySystem component level VPD tracking activity log action(added/removed). View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.18.1.7ColumncomponentLevelVpdTrackingTimestampread-onlymandatorySystem component level VPD tracking activity log timestanp. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.19TablehostMACAddressTablenot-accessiblemandatoryTable of MAC addresses of the host NICs. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.19046.11.1.1.5.19.1RowhostMACAddressEntrynot-accessiblemandatoryHost MAC address entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.19046.11.1.1.5.19.1.1ColumnhostMACAddressIndexread-onlymandatoryHost MAC address index. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.19.1.2ColumnhostMACAddressDescriptionread-onlymandatoryDescription of the MAC Address entry. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.19.1.3ColumnhostMACAddressread-onlymandatoryHost MAC address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value must be in the form XX:XX:XX:XX:XX:XX View as a table and not as i…
1.3.6.1.4.1.19046.11.1.1.5.20TablesystemCPUVpdTablenot-accessiblemandatoryTable of the system CPU VPD information. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.20.1RowsystemCPUVpdEntrynot-accessiblemandatorySystem CPU VPD entry. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.20.1.1ColumncpuVpdIndexread-onlymandatorySystem CPU level VPD index. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.20.1.2ColumncpuVpdDescriptionread-onlymandatorySystem CPU Description. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.20.1.3ColumncpuVpdSpeedread-onlymandatorySystem cpu speed in MHz. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.20.1.4ColumncpuVpdIdentifierread-onlymandatorySystem CPU Identifier. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.20.1.5ColumncpuVpdTyperead-onlymandatorySystem cpu Type. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.20.1.6ColumncpuVpdFamilyread-onlymandatorySystem cpu Family. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.20.1.7ColumncpuVpdCoresread-onlymandatorySystem cpu number of cores. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.20.1.8ColumncpuVpdThreadsread-onlymandatorySystem cpu number of threads. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.20.1.9ColumncpuVpdVoltageread-onlymandatorySystem cpu voltage in millivolts (1125 = 1.125 volts). View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.20.1.10ColumncpuVpdDataWidthread-onlymandatorySystem cpu data width in bits. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.20.1.11ColumncpuVpdHealthStatusread-onlymandatorySystem cpu health status. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.20.1.12ColumncpuVpdCpuModelread-onlymandatorySystem cpu model. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.21TablesystemMemoryVpdTablenot-accessiblemandatoryTable of the system Memory VPD information. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.21.1RowsystemMemoryVpdEntrynot-accessiblemandatorySystem Memory VPD entry. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.21.1.1ColumnmemoryVpdIndexread-onlymandatorySystem Memory level VPD index. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.21.1.2ColumnmemoryVpdDescriptionread-onlymandatorySystem memory Description (e.g. DIMM 1). View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.21.1.3ColumnmemoryVpdPartNumberread-onlymandatorySystem Memory Part Number. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.21.1.4ColumnmemoryVpdFRUSerialNumberread-onlymandatorySystem memory Serial Number. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.21.1.5ColumnmemoryVpdManufactureDateread-onlymandatorySystem memory Manufacture Date in week/year format (e.g. 3609). View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.21.1.6ColumnmemoryVpdTyperead-onlymandatorySystem memory Type (e.g. DDR III SDRAM). View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.21.1.7ColumnmemoryVpdSizeread-onlymandatorySystem memory size in GigaBytes. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.21.1.8ColumnmemoryHealthStatusread-onlymandatoryA description of the memory component status.
1.3.6.1.4.1.19046.11.1.1.5.21.1.9ColumnmemoryConfigSpeedread-onlymandatorySystem configured memory clock speed in MHz. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.21.1.10ColumnmemoryRatedSpeedread-onlymandatorySystem rated memory clock speed in MB/s. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.21.1.11ColumnmemoryLenovoPartNumberread-onlymandatorySystem Memory Lenovo related Part Number. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.21.1.12ColumnmemoryVpdAEPFlagread-onlymandatoryJudge System DIMM belong to AEP DIMM. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.22TablesystemAepDIMMVpdTablenot-accessiblemandatoryTable of the system AEP DIMM VPD information. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.22.1RowsystemAepDIMMVpdEntrynot-accessiblemandatorySystem AEP DIMM VPD entry. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.22.1.1ColumnaepDIMMVpdIndexread-onlymandatorySystem AEP DIMM VPD index. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.22.1.2ColumnaepDIMMVpdMemoryread-onlymandatorySystem AEP DIMM Description (e.g. DIMM 1). View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.22.1.3ColumnaepDIMMVpdBankLocatorread-onlymandatoryThe Locator which manage AEP DIMM (e.g CPU 1) . View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.22.1.4ColumnaepDIMMVpdMaxSpeedread-onlymandatorySystem AEP DIMM MAX Speed. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.22.1.5ColumnaepDIMMVpdClockSpeedread-onlymandatorySystem AEP DIMM Clock Speed. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.22.1.6ColumnaepDIMMVpdManufacturerread-onlymandatorySystem AEP DIMM Manufacturer. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.22.1.7ColumnaepDIMMVpdSerialNumberread-onlymandatorySystem AEP DIMM Serial Number. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.22.1.8ColumnaepDIMMVpdPartNumberread-onlymandatorySystem AEP DIMM Part Number. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.22.1.9ColumnaepDIMMVpdRawCapacityread-onlymandatorySystem AEP DIMM Raw Capacity. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.22.1.10ColumnaepDIMMVpdMemoryCapacityread-onlymandatorySystem AEP DIMM Memory Capacity. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.22.1.11ColumnaepDIMMVpdAppDirectCapacityread-onlymandatorySystem AEP DIMM APP Direct Capacity. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.22.1.12ColumnaepDIMMVpdUnconfiguredCapacityread-onlymandatorySystem AEP DIMM Unconfigureed Capacity. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.22.1.13ColumnaepDIMMVpdInaccessibleCapacityread-onlymandatorySystem AEP DIMM Inaccessible Capacity. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.22.1.14ColumnaepDIMMVpdReservedCapacityread-onlymandatorySystem AEP DIMM Reserved Capacity. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.22.1.15ColumnaepDIMMVpdClassificationread-onlymandatorySystem AEP DIMM Classification. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.22.1.16ColumnaepDIMMVpdFirmwareVersionread-onlymandatorySystem AEP DIMM Firmware Version. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.5.22.1.17ColumnaepDIMMVpdSoftwareIDread-onlymandatorySystem AEP DIMM Software ID. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.6Nodeusers
1.3.6.1.4.1.19046.11.1.1.6.1NodexccUsers
1.3.6.1.4.1.19046.11.1.1.6.1.1TablecurrentlyLoggedInTablenot-accessiblemandatoryTable of XCC users currently logged in.
1.3.6.1.4.1.19046.11.1.1.6.1.1.1RowcurrentlyLoggedInEntrynot-accessiblemandatoryXCC users currently logged in entries.
1.3.6.1.4.1.19046.11.1.1.6.1.1.1.1ColumncurrentlyLoggedInEntryIndexread-onlymandatoryIndex for XCC users currently logged in.
1.3.6.1.4.1.19046.11.1.1.6.1.1.1.2ColumncurrentlyLoggedInEntryUserIdread-onlymandatoryName for XCC users currently logged in.
1.3.6.1.4.1.19046.11.1.1.6.1.1.1.3ColumncurrentlyLoggedInEntryAccMethodread-onlymandatoryAccess method for XCC users currently logged in.
1.3.6.1.4.1.19046.11.1.1.8Nodeleds
1.3.6.1.4.1.19046.11.1.1.8.1ScalaridentityLEDread-onlymandatoryIndicates whether the front panel identity LED is on,off, or blinking and allows user to change it.
1.3.6.1.4.1.19046.11.1.1.8.2TableallLEDsTablenot-accessiblemandatoryTable of LEDs detailed information.
1.3.6.1.4.1.19046.11.1.1.8.2.1RowallLEDsEntrynot-accessiblemandatoryLEDs Details entry
1.3.6.1.4.1.19046.11.1.1.8.2.1.1ColumnledIndexread-onlymandatoryThe LED index number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.19046.11.1.1.8.2.1.2ColumnledIdentifierread-onlymandatoryThe unique identifier for this LED For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.19046.11.1.1.8.2.1.4ColumnledLabelread-onlymandatoryText label for a LED. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.19046.11.1.1.8.2.1.5ColumnledStateread-onlymandatoryText description which denotes color or on/off/blink state for a LED. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.19046.11.1.1.8.2.1.6ColumnledColorread-onlymandatoryColor of this LED. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.19046.11.1.1.8.3ScalarinformationLEDread-onlymandatoryIndicates whether the front panel Information LED is on,off, or blinking and allows user to change it. The only value the user is allowed to enter is 0 for off…
1.3.6.1.4.1.19046.11.1.1.10NodefuelGauge
1.3.6.1.4.1.19046.11.1.1.10.1NodefuelGaugeInformation
1.3.6.1.4.1.19046.11.1.1.10.1.1ScalarfuelGaugePowerCappingPolicySettingread-onlymandatoryPower Capping Policy. Rack system only. No Power Limit - The maximum power limit will be determined by the active Power Redundancy policy. Static Power Limit -…
1.3.6.1.4.1.19046.11.1.1.10.1.2ScalarfuelGaugeStaticPowerPcapSoftMinread-onlymandatoryThis field displays power capping soft minimum value. Rack system only.
1.3.6.1.4.1.19046.11.1.1.10.1.3ScalarfuelGaugeStaticPowerPcapMinread-onlymandatoryThis field displays power capping minimum value. Rack system only.
1.3.6.1.4.1.19046.11.1.1.10.1.4ScalarfuelGaugeStaticPowerPcapCurrentSettingread-onlymandatoryThis field is used to display or set the current power capping value. Rack system only.
1.3.6.1.4.1.19046.11.1.1.10.1.5ScalarfuelGaugeStaticPowerPcapMaxread-onlymandatoryThis field displays power capping maximum value. Rack system only.
1.3.6.1.4.1.19046.11.1.1.10.1.6ScalarfuelGaugeStaticPowerPcapModeread-onlymandatoryThis field is used to display or set the all Power Cap settings to output or input. Rack system only.
1.3.6.1.4.1.19046.11.1.1.10.1.7ScalarfuelGaugeSystemMaxPowerread-onlymandatoryThis field displays the system maximum power available value. Rack system only.
1.3.6.1.4.1.19046.11.1.1.10.1.8ScalarfuelGaugePowerRemainingread-onlymandatoryThis field displays power remaining value. Rack system only.
1.3.6.1.4.1.19046.11.1.1.10.1.9ScalarfuelGaugeTotalPowerAvailableread-onlymandatoryThis field displays the calculated total remaining power available value. Rack system only.
1.3.6.1.4.1.19046.11.1.1.10.1.10ScalarfuelGaugeTotalPowerInUseread-onlymandatoryThis field displays total power in use value.
1.3.6.1.4.1.19046.11.1.1.10.1.11ScalarfuelGaugePowerConsumptionCpuread-onlymandatoryThis field displays the power consumption of the processors.
1.3.6.1.4.1.19046.11.1.1.10.1.12ScalarfuelGaugePowerConsumptionMemoryread-onlymandatoryThis field displays the power consumption of the memory.
1.3.6.1.4.1.19046.11.1.1.10.1.13ScalarfuelGaugePowerConsumptionOtherread-onlymandatoryThis field displays the power consumption of other entities than processors and memory.
1.3.6.1.4.1.19046.11.1.1.10.2NodepowerPolicyInformation
1.3.6.1.4.1.19046.11.1.1.10.2.1TablepowerPolicyTablenot-accessiblemandatoryTable of Power Policy information for all power domains. Reading this table information about the available power policies that can be configured and which is …
1.3.6.1.4.1.19046.11.1.1.10.2.1.1RowpowerPolicyEntrynot-accessiblemandatoryPower Policy Entry
1.3.6.1.4.1.19046.11.1.1.10.2.1.1.1ColumnpowerPolicyIndexread-onlymandatoryThe unique idenitifier of a row in the powerPolicyTable.
1.3.6.1.4.1.19046.11.1.1.10.2.1.1.2ColumnpowerPolicyNameread-onlymandatoryThe short name of the power policy. The following are the possible names and their detailed description: Power Module Redundant In redundant mode, the server i…
1.3.6.1.4.1.19046.11.1.1.10.2.1.1.3ColumnpowerPolicyPwrSupplyFailureLimitread-onlymandatoryThe maximum number of power supplies that can fail in a chassis while still providing redundancy.
1.3.6.1.4.1.19046.11.1.1.10.2.1.1.4ColumnpowerPolicyMaxPowerLimitread-onlymandatoryThe maximum power available (in watts), based on the number of power modules and the Power Management Policy setting.
1.3.6.1.4.1.19046.11.1.1.10.2.1.1.5ColumnpowerPolicyEstimatedUtilizationread-onlymandatoryThe estimated utilization (as a percentage) based on current power usage.
1.3.6.1.4.1.19046.11.1.1.10.2.1.1.6ColumnpowerPolicyActivateread-onlymandatoryThis object provides the status of this power policy. If the value is enabled(1), it means this is the active power policy for the associated domain. When set …
1.3.6.1.4.1.19046.11.1.1.10.2.2NodepowerRestorePolicyControl
1.3.6.1.4.1.19046.11.1.1.10.2.2.1ScalarpowerRestorePolicyread-onlymandatoryPower Restore Policy determines the mode of operation if a power loss occurs. This setting can also be configured via BIOS F1 setup. Rack system only. alwaysof…
1.3.6.1.4.1.19046.11.1.1.10.2.2.2ScalarpowerRestoreDelayread-onlymandatoryPower Restore Delay is executed when power restore policy is set to alwayson or restore(if the previous state was power-on). Rack system only. disabled: Power …
1.3.6.1.4.1.19046.11.1.1.10.3NodepowerPowerTrending
1.3.6.1.4.1.19046.11.1.1.10.3.1TablepowerTrendingSampleTablenot-accessiblemandatoryTable of Power Domain 1 Power Trending Information.
1.3.6.1.4.1.19046.11.1.1.10.3.1.1RowpowerTrendingSampleEntrynot-accessiblemandatoryPower Domain 1 Power Trending Sample entry.
1.3.6.1.4.1.19046.11.1.1.10.3.1.1.1ColumnpowerTrendingSampleIndexread-onlymandatoryPower Trending Sample Table Index.
1.3.6.1.4.1.19046.11.1.1.10.3.1.1.2ColumnpowerTrendingSampleTimeStampread-onlymandatoryPower Trending Sample Table Timestamp.
1.3.6.1.4.1.19046.11.1.1.10.3.1.1.3ColumnpowerTrendingSampleInputAveread-onlymandatoryPower Trending Table Input Average Power in the last 24 hours.
1.3.6.1.4.1.19046.11.1.1.10.3.1.1.4ColumnpowerTrendingSampleInputMinread-onlymandatoryPower Trending Table Input Minimum Power in the last 24 hours.
1.3.6.1.4.1.19046.11.1.1.10.3.1.1.5ColumnpowerTrendingSampleInputMaxread-onlymandatoryPower Trending Table Input Maximum Power in the last 24 hours.
1.3.6.1.4.1.19046.11.1.1.10.3.1.1.6ColumnpowerTrendingSampleOutputAveread-onlymandatoryPower Trending Table Output Average Power in the last 24 hours.
1.3.6.1.4.1.19046.11.1.1.10.3.1.1.7ColumnpowerTrendingSampleOutputMinread-onlymandatoryPower Trending Table Output Minimum Power in the last 24 hours.
1.3.6.1.4.1.19046.11.1.1.10.3.1.1.8ColumnpowerTrendingSampleOutputMaxread-onlymandatoryPower Trending Table Output Maximum Power in the last 24 hours.
1.3.6.1.4.1.19046.11.1.1.11NodepowerModule
1.3.6.1.4.1.19046.11.1.1.11.1ScalarpowerNumberread-onlymandatoryThe present number of rows in the power module table. Rack system only.
1.3.6.1.4.1.19046.11.1.1.11.2TablepowerTablenot-accessiblemandatoryThis table contains power inventory information. Rack system only.
1.3.6.1.4.1.19046.11.1.1.11.2.1RowpowerEntrynot-accessiblemandatoryEach row contains parameters related to a power module inventory channel.
1.3.6.1.4.1.19046.11.1.1.11.2.1.1ColumnpowerIndexread-onlymandatoryThis column is used to identify a particular power module inventory channel.
1.3.6.1.4.1.19046.11.1.1.11.2.1.2ColumnpowerFruNameread-onlymandatorypower module FRU name.
1.3.6.1.4.1.19046.11.1.1.11.2.1.3ColumnpowerPartNumberread-onlymandatorypower module Part Number. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.11.2.1.4ColumnpowerFRUNumberread-onlymandatorypower module FRU Number. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.11.2.1.5ColumnpowerFRUSerialNumberread-onlymandatorypower module Serial Number. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.1.11.2.1.6ColumnpowerHealthStatusread-onlymandatoryA description of the power module status.
1.3.6.1.4.1.19046.11.1.1.12Nodedisks
1.3.6.1.4.1.19046.11.1.1.12.1ScalardiskNumberread-onlymandatoryThe present number of rows in the disk module table.
1.3.6.1.4.1.19046.11.1.1.12.2TablediskTablenot-accessiblemandatoryThis table contains disk inventory information.
1.3.6.1.4.1.19046.11.1.1.12.2.1RowdiskEntrynot-accessiblemandatoryEach row contains parameters related to a disk module inventory channel.
1.3.6.1.4.1.19046.11.1.1.12.2.1.1ColumndiskIndexread-onlymandatoryThis column is used to identify a particular disk module inventory channel.
1.3.6.1.4.1.19046.11.1.1.12.2.1.2ColumndiskFruNameread-onlymandatorydisk module FRU name.
1.3.6.1.4.1.19046.11.1.1.12.2.1.3ColumndiskHealthStatusread-onlymandatoryA description of the disk module status.
1.3.6.1.4.1.19046.11.1.1.13NodelocalStorage
1.3.6.1.4.1.19046.11.1.1.13.1Noderaid
1.3.6.1.4.1.19046.11.1.1.13.1.1ScalarraidOOBCapableread-onlymandatoryIf raidOOBCapable is disabled, all the RAID information is not available.
1.3.6.1.4.1.19046.11.1.1.13.1.2TableraidControllerTablenot-accessiblemandatoryTable of Local Storage RAID Controller information.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1RowraidControllerEntrynot-accessiblemandatoryRAID Controller Entry.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.1ColumnraidCtrlIndexread-onlymandatoryThis column is used to identify a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.2ColumnraidCtrlNameread-onlymandatoryThis column is used to offer a name of one RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.3ColumnraidCtrlVPDProdNameread-onlymandatoryThe Product Name of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.4ColumnraidCtrlFWPkgVersionread-onlymandatoryThe Firmware Package Version of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.5ColumnraidCtrlBatBCKread-onlymandatoryWhether Battery Backup of a particular RAID controller is installed.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.6ColumnraidCtrlVPDManufactureread-onlymandatoryThe Manufacture of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.7ColumnraidCtrlVPDUUIDread-onlymandatoryThe Device ID (UUID) of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.8ColumnraidCtrlVPDMachineTyperead-onlymandatoryThe Model Type/Model of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.9ColumnraidCtrlVPDModelread-onlymandatoryThe Model Type/Model of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.10ColumnraidCtrlVPDSerialNoread-onlymandatoryThe Serial Number of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.11ColumnraidCtrlVPDFRUNoread-onlymandatoryThe FRU Number of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.12ColumnraidCtrlVPDPartNoread-onlymandatoryThe Part Number of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.13ColumnraidCtrlCacheMdlStatusread-onlymandatoryThe Cache Model Status of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.14ColumnraidCtrlCacheMdlMemSizeread-onlymandatoryThe Cache Model Memory Size of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.15ColumnraidCtrlCacheMdlSerialNoread-onlymandatoryThe Cache Model Serial Number of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.16ColumnraidCtrlPCISlotNoread-onlymandatoryThe PCI Slot Number of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.17ColumnraidCtrlPCIBusNoread-onlymandatoryThe PCI Bus Number of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.18ColumnraidCtrlPCIDevNoread-onlymandatoryThe PCI Device Number of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.19ColumnraidCtrlPCIFuncNoread-onlymandatoryThe PCI Function Number of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.20ColumnraidCtrlPCIDevIDread-onlymandatoryThe PCI Device ID of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.21ColumnraidCtrlPCISubDevIDread-onlymandatoryThe PCI Subsystem Device ID of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.22ColumnraidCtrlBatBCKProdNameread-onlymandatoryThe Product Name of Battery Backup of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.23ColumnraidCtrlBatBCKManufactureread-onlymandatoryThe Manufacture of Battery Backup of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.24ColumnraidCtrlBatBCKStatusread-onlymandatoryThe Status of Battery Backup of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.25ColumnraidCtrlBatBCKTyperead-onlymandatoryThe Battery Type of Battery Backup of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.26ColumnraidCtrlBatBCKChemread-onlymandatoryThe Chemistry of Battery Backup of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.27ColumnraidCtrlBatBCKSerialNoread-onlymandatoryThe Serial Number of Battery Backup of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.28ColumnraidCtrlBatBCKChgCapread-onlymandatoryThe Charge Capacity of Battery Backup of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.29ColumnraidCtrlBatBCKFirmwareread-onlymandatoryThe Firmware Info of Battery Backup of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.30ColumnraidCtrlBatBCKDgnVoltageread-onlymandatoryThe Designed Voltage of Battery Backup of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.31ColumnraidCtrlBatBCKVoltageread-onlymandatoryThe Voltage of Battery Backup of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.32ColumnraidCtrlBatCurrentread-onlymandatoryThe Current of Battery Backup of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.33ColumnraidCtrlBatBCKDgnChgCapread-onlymandatoryThe Design Charge Capacity of Battery Backup of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.34ColumnraidCtrlBatBCKCrtTempread-onlymandatoryThe Current degree Celsius temperature of Battery Backup of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.35ColumnraidCtrlFWNamesread-onlymandatoryAll the Firmware Names of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.36ColumnraidCtrlPortDetailsread-onlymandatoryAll the Port Details of a particular RAID controller, including Port Address and Port Controller Type.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.37ColumnraidCtrlStoragepoolsread-onlymandatoryThe storage pools list of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.2.1.38ColumnraidCtrlDrivesread-onlymandatoryThe Physical drives list of a particular RAID controller.
1.3.6.1.4.1.19046.11.1.1.13.1.3TableraidDriveTablenot-accessiblemandatoryTable of Logic Storage RAID Drive information.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1RowraidDriveEntrynot-accessiblemandatoryRAID Drive Entry.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1.1ColumnraidDriveIndexread-onlymandatoryThis column is used to identify a particular RAID drive.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1.2ColumnraidDriveNameread-onlymandatoryA particular drive name.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1.3ColumnraidDriveVPDProdNameread-onlymandatoryThe Product Name of a particular RAID drive.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1.4ColumnraidDriveStateread-onlymandatoryThe State of a particular RAID drive.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1.5ColumnraidDriveSlotNoread-onlymandatoryThe Slot No. of a particular RAID drive.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1.6ColumnraidDriveDeviceIDread-onlymandatoryThe Device ID of a particular RAID drive.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1.7ColumnraidDriveDiskTyperead-onlymandatoryThe Disk Type of a particular RAID drive.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1.8ColumnraidDriveMediaTyperead-onlymandatoryThe Media Type of a particular RAID drive.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1.9ColumnraidDriveSpeedread-onlymandatoryThe Speed of a particular RAID drive.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1.10ColumnraidDriveCurTempread-onlymandatoryThe Current degree Celsius temperature of a particular RAID drive.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1.11ColumnraidDriveHealthStatausread-onlymandatoryThe Health Status of a particular RAID drive.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1.12ColumnraidDriveCapacityread-onlymandatoryThe Capacity of a particular RAID drive.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1.13ColumnraidDriveVPDManufactureread-onlymandatoryThe Manufacture of a particular RAID drive.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1.14ColumnraidDriveEnclosureIDread-onlymandatoryThe Enclosure ID of a particular RAID drive.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1.15ColumnraidDriveVPDMachineTyperead-onlymandatoryThe Machine type of a particular RAID drive.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1.16ColumnraidDriveVPDModelread-onlymandatoryThe Model of a particular RAID drive.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1.17ColumnraidDriveVPDSerialNoread-onlymandatoryThe Serial No. of a particular RAID drive.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1.18ColumnraidDriveVPDFRUNoread-onlymandatoryThe FRU No. of a particular RAID drive.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1.19ColumnraidDriveVPDPartNoread-onlymandatoryThe Part No. of a particular RAID drive.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1.20ColumnraidDriveFWNamesread-onlymandatoryAll the Firmware Names of a particular RAID drive.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1.21ColumnraidDriveRotationRateread-onlymandatoryThe Rotation Rate of a particular RAID drive.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1.22ColumnraidDriveMediaErrCntread-onlymandatoryThe Media Error Count of a particular RAID drive.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1.23ColumnraidDriveOtherErrCntread-onlymandatoryThe Other Error Count of a particular RAID drive.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1.24ColumnraidDrivePredFailCntread-onlymandatoryThe Predication Fail Count of a particular RAID drive.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1.25ColumnraidDriveRemainingLiferead-onlymandatoryThe Remaining life of a particular RAID drive. It is available only for SSD Drive.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1.26ColumnraidDriveFdeCapableread-onlymandatoryIndicates Full Disk Encryption Capable of a particular RAID drive.
1.3.6.1.4.1.19046.11.1.1.13.1.3.1.27ColumnraidDriveSecuredread-onlymandatoryIndicates Secured status of a particular RAID drive.
1.3.6.1.4.1.19046.11.1.1.13.1.4TableraidControllerFirmwareTablenot-accessiblemandatoryTable of Logic Storage RAID Controller Firmware information.
1.3.6.1.4.1.19046.11.1.1.13.1.4.1RowraidControllerFirmwareEntrynot-accessiblemandatoryRAID Firmware Entry.
1.3.6.1.4.1.19046.11.1.1.13.1.4.1.1ColumnraidControllerFirmwareIndexread-onlymandatoryThis column is used to identify a particular RAID Controller firmware.
1.3.6.1.4.1.19046.11.1.1.13.1.4.1.2ColumnraidControllerFirmwareNameread-onlymandatoryThe Name of a particular RAID Controller firmware.
1.3.6.1.4.1.19046.11.1.1.13.1.4.1.3ColumnraidControllerFirmwareCtrlNameread-onlymandatoryThe controller name of the firmwares.
1.3.6.1.4.1.19046.11.1.1.13.1.4.1.4ColumnraidControllerFirmwareDescriptionread-onlymandatoryThe Description of a particular RAID Controller firmware.
1.3.6.1.4.1.19046.11.1.1.13.1.4.1.5ColumnraidControllerFirmwareManufactureread-onlymandatoryThe Manufacture of a particular RAID Controller firmware.
1.3.6.1.4.1.19046.11.1.1.13.1.4.1.6ColumnraidControllerFirmwareVersionread-onlymandatoryThe Version of a particular RAID Controller firmware.
1.3.6.1.4.1.19046.11.1.1.13.1.4.1.7ColumnraidControllerFirmwareReleaseDateread-onlymandatoryThe Release Date of a particular RAID Controller firmware.
1.3.6.1.4.1.19046.11.1.1.13.1.5TableraidDriveFirmwareTablenot-accessiblemandatoryTable of Logic Storage RAID Drive Firmware information.
1.3.6.1.4.1.19046.11.1.1.13.1.5.1RowraidDriveFirmwareEntrynot-accessiblemandatoryRAID Drive Firmware Entry.
1.3.6.1.4.1.19046.11.1.1.13.1.5.1.1ColumnraidDriveFirmwareIndexread-onlymandatoryThis column is used to identify a particular RAID Drive firmware.
1.3.6.1.4.1.19046.11.1.1.13.1.5.1.2ColumnraidDriveFirmwareNameread-onlymandatoryThe Name of a particular RAID Drive firmware.
1.3.6.1.4.1.19046.11.1.1.13.1.5.1.3ColumnraidDriveFirmwareDriveNameread-onlymandatoryThe drive name of the firmwares.
1.3.6.1.4.1.19046.11.1.1.13.1.5.1.4ColumnraidDriveFirmwareDescriptionread-onlymandatoryThe Description of a particular RAID Drive firmware.
1.3.6.1.4.1.19046.11.1.1.13.1.5.1.5ColumnraidDriveFirmwareManufactureread-onlymandatoryThe Manufacture of a particular RAID Drive firmware.
1.3.6.1.4.1.19046.11.1.1.13.1.5.1.6ColumnraidDriveFirmwareVersionread-onlymandatoryThe Version of a particular RAID Drive firmware.
1.3.6.1.4.1.19046.11.1.1.13.1.5.1.7ColumnraidDriveFirmwareReleaseDateread-onlymandatoryThe Release Date of a particular RAID Drive firmware.
1.3.6.1.4.1.19046.11.1.1.13.1.6TableraidStoragepoolTablenot-accessiblemandatoryTable of Logic Storage RAID Storagepool information.
1.3.6.1.4.1.19046.11.1.1.13.1.6.1RowraidStoragepoolEntrynot-accessiblemandatoryRAID Storagepool Entry.
1.3.6.1.4.1.19046.11.1.1.13.1.6.1.1ColumnraidStoragepoolIndexread-onlymandatoryThis column is used to identify a particular RAID storagepool.
1.3.6.1.4.1.19046.11.1.1.13.1.6.1.2ColumnraidStoragepoolNameread-onlymandatoryThe name of a particular RAID storagepool.
1.3.6.1.4.1.19046.11.1.1.13.1.6.1.3ColumnraidStoragepoolControllerNameread-onlymandatoryThe controller name of the storagepool.
1.3.6.1.4.1.19046.11.1.1.13.1.6.1.4ColumnraidStoragepoolStateread-onlymandatoryThe RAID State of a particular RAID storagepool.
1.3.6.1.4.1.19046.11.1.1.13.1.6.1.5ColumnraidStoragepoolCapacityread-onlymandatoryThe Capacity of a particular RAID storagepool, including total capacity and free capacity.
1.3.6.1.4.1.19046.11.1.1.13.1.6.1.6ColumnraidStoragepoolVolsread-onlymandatoryThe volumes list of a particular RAID storagepool.
1.3.6.1.4.1.19046.11.1.1.13.1.6.1.7ColumnraidStoragepoolDrivesread-onlymandatoryThe physical drives list of a particular RAID storagepool.
1.3.6.1.4.1.19046.11.1.1.13.1.7TableraidVolumeTablenot-accessiblemandatoryTable of Logic Storage RAID Volume information.
1.3.6.1.4.1.19046.11.1.1.13.1.7.1RowraidVolumeEntrynot-accessiblemandatoryRAID Volume Entry.
1.3.6.1.4.1.19046.11.1.1.13.1.7.1.1ColumnraidVolumeIndexread-onlymandatoryThis column is used to identify a particular RAID volume.
1.3.6.1.4.1.19046.11.1.1.13.1.7.1.2ColumnraidVolumeNameread-onlymandatoryThe Name of a particular RAID volume.
1.3.6.1.4.1.19046.11.1.1.13.1.7.1.3ColumnraidVolumeControllerNameread-onlymandatoryThe controller name of the volume.
1.3.6.1.4.1.19046.11.1.1.13.1.7.1.4ColumnraidVolumeStatusread-onlymandatoryThe Status of a particular RAID volume.
1.3.6.1.4.1.19046.11.1.1.13.1.7.1.5ColumnraidVolumeCapacityread-onlymandatoryThe Capacity of a particular RAID volume.
1.3.6.1.4.1.19046.11.1.1.13.1.7.1.6ColumnraidVolumeStripSizeread-onlymandatoryThe strip size of the RAID volume.
1.3.6.1.4.1.19046.11.1.1.13.1.7.1.7ColumnraidVolumeBootableread-onlymandatoryWhether the RAID volume is bootable.
1.3.6.1.4.1.19046.11.1.1.14Nodeadapters
1.3.6.1.4.1.19046.11.1.1.14.1ScalaradapterOOBCapableread-onlymandatoryIf adapterOOBCapable is disabled, all the adapter information is not available.
1.3.6.1.4.1.19046.11.1.1.14.2TableadapterGenericTablenot-accessiblemandatoryTable of all adapters generic information
1.3.6.1.4.1.19046.11.1.1.14.2.1RowadapterGenericEntrynot-accessiblemandatoryAdapters generic information entry.
1.3.6.1.4.1.19046.11.1.1.14.2.1.1ColumnadapterGenericIndexread-onlymandatoryThis column is used to identify a particular PCI adapter.
1.3.6.1.4.1.19046.11.1.1.14.2.1.2ColumnadapterGenericVPDProdNameread-onlymandatoryThe Product Name of a particular PCI adapter. And if the Product Name contains PFA, PFA is in HEX.
1.3.6.1.4.1.19046.11.1.1.14.2.1.3ColumnadapterGenericSlotNoread-onlymandatoryThis Slot No. of a particular PCI adapter
1.3.6.1.4.1.19046.11.1.1.14.2.1.4ColumnadapterGenericLocationread-onlymandatoryThe Location of a particular PCI adapter.
1.3.6.1.4.1.19046.11.1.1.14.2.1.5ColumnadapterGenericCardInterfaceread-onlymandatoryThe Card Interface of a particular PCI adapter.
1.3.6.1.4.1.19046.11.1.1.14.3TableadapterNetworkFunctionTablenot-accessiblemandatoryTable of Network Function information.
1.3.6.1.4.1.19046.11.1.1.14.3.1RowadapterNetworkFunctionEntrynot-accessiblemandatoryNetwork function information entry.
1.3.6.1.4.1.19046.11.1.1.14.3.1.1ColumnadapterNetworkFunctionIndexread-onlymandatoryThis column is used to identify a particular network function.
1.3.6.1.4.1.19046.11.1.1.14.3.1.2ColumnadapterNetworkFunctionNetworkVPDProdNameread-onlymandatoryThe Product Name and PFA of a particular network function and PFA is in HEX.
1.3.6.1.4.1.19046.11.1.1.14.3.1.3ColumnadapterNetworkFunctionAdapterVPDProdNameread-onlymandatoryThe Product Name of a particular adapter providing this function. And if the Product Name contains PFA, PFA is in HEX.
1.3.6.1.4.1.19046.11.1.1.14.3.1.4ColumnadapterNetworkFunctionNetworkVPDManufacturerread-onlymandatoryThe Manufacturer of a particular network function.
1.3.6.1.4.1.19046.11.1.1.14.3.1.5ColumnadapterNetworkFunctionNetworkVPDUUIDread-onlymandatoryThe UUID of a particular network function.
1.3.6.1.4.1.19046.11.1.1.14.3.1.6ColumnadapterNetworkFunctionNetworkVPDModelread-onlymandatoryThe Model of a particular network function.
1.3.6.1.4.1.19046.11.1.1.14.3.1.7ColumnadapterNetworkFunctionNetworkVPDSerialNoread-onlymandatoryThe Serial No. of a particular network function.
1.3.6.1.4.1.19046.11.1.1.14.3.1.8ColumnadapterNetworkFunctionNetworkVPDFRUNoread-onlymandatoryThe FRU No. of a particular network function.
1.3.6.1.4.1.19046.11.1.1.14.3.1.9ColumnadapterNetworkFunctionNetworkVPDPartNoread-onlymandatoryThe Part No. of a particular network function.
1.3.6.1.4.1.19046.11.1.1.14.3.1.10ColumnadapterNetworkFunctionFoDUIDread-onlymandatoryThe FoD UID of a particular network function.
1.3.6.1.4.1.19046.11.1.1.14.3.1.11ColumnadapterNetworkFunctionSupportHotPlugread-onlymandatoryIndicates whether the network function supports hot plug.
1.3.6.1.4.1.19046.11.1.1.14.3.1.12ColumnadapterNetworkFunctionPhysicalPortNumberread-onlymandatoryThe Physical Port Number of a particular network function.
1.3.6.1.4.1.19046.11.1.1.14.3.1.13ColumnadapterNetworkFunctionMaxPortNumberread-onlymandatoryThe Max Port Number of a particular network function.
1.3.6.1.4.1.19046.11.1.1.14.3.1.14ColumnadapterNetworkFunctionPortNumberread-onlymandatoryThe Port Number of a particular network function.
1.3.6.1.4.1.19046.11.1.1.14.3.1.15ColumnadapterNetworkFunctionMaxDataWidthread-onlymandatoryThe Maximum Data Width in Gbps of a particular network funtion.
1.3.6.1.4.1.19046.11.1.1.14.3.1.16ColumnadapterNetworkFunctionPackageTyperead-onlymandatoryThe Package Type of a particular network function.
1.3.6.1.4.1.19046.11.1.1.14.3.1.17ColumnadapterNetworkFunctionPCIBusNoread-onlymandatoryThe PCI Bus No. of a particular network function.
1.3.6.1.4.1.19046.11.1.1.14.3.1.18ColumnadapterNetworkFunctionPCIDevNoread-onlymandatoryThe PCI Device No. of a particular network function.
1.3.6.1.4.1.19046.11.1.1.14.3.1.19ColumnadapterNetworkFunctionPCIFuncNoread-onlymandatoryThe PCI Function No. of a particular network function.
1.3.6.1.4.1.19046.11.1.1.14.3.1.20ColumnadapterNetworkFunctionPCIVendorIdread-onlymandatoryThe PCI Vendor ID of a particular network function.
1.3.6.1.4.1.19046.11.1.1.14.3.1.21ColumnadapterNetworkFunctionPCIDevIdread-onlymandatoryThe PCI Device ID of a particular network function.
1.3.6.1.4.1.19046.11.1.1.14.3.1.22ColumnadapterNetworkFunctionPCIDevTyperead-onlymandatoryThe PCI Device Type of a particular network function.
1.3.6.1.4.1.19046.11.1.1.14.3.1.23ColumnadapterNetworkFunctionPCIRevIdread-onlymandatoryThe PCI Revision ID of a particular network function.
1.3.6.1.4.1.19046.11.1.1.14.3.1.24ColumnadapterNetworkFunctionPCISubVendorIdread-onlymandatoryThe PCI Subsystem Vendor ID of a particular network function.
1.3.6.1.4.1.19046.11.1.1.14.3.1.25ColumnadapterNetworkFunctionPCISubDevIdread-onlymandatoryThe PCI Subsystem Device ID of a particular network function.
1.3.6.1.4.1.19046.11.1.1.14.3.1.26ColumnadapterNetworkFunctionPCISlotDesignationread-onlymandatoryThe PCI Slot Designation of a particular network function.
1.3.6.1.4.1.19046.11.1.1.14.4TableadapterNetworkPortTablenot-accessiblemandatoryTable of Ports of Network Function information.
1.3.6.1.4.1.19046.11.1.1.14.4.1RowadapterNetworkPortEntrynot-accessiblemandatoryPorts of Network Function information entry.
1.3.6.1.4.1.19046.11.1.1.14.4.1.1ColumnadapterNetworkPortIndexread-onlymandatoryThis column is used to identify a particular network port.
1.3.6.1.4.1.19046.11.1.1.14.4.1.2ColumnadapterNetworkPortNetworkVPDProdNameread-onlymandatoryThe Product Name and PFA of the network function for this port and PFA is in HEX.
1.3.6.1.4.1.19046.11.1.1.14.4.1.3ColumnadapterNetworkPortPhyPortNoread-onlymandatoryThe Physical Port No. in the network function for this port.
1.3.6.1.4.1.19046.11.1.1.14.4.1.4ColumnadapterNetworkPortPhyPortConnectorread-onlymandatoryThe Physical Port Connector Layout in the network function for this port.
1.3.6.1.4.1.19046.11.1.1.14.4.1.5ColumnadapterNetworkPortPhyPortBurnedinAddressread-onlymandatoryThe Physical Permanent (burned-In) Address of a particular network port.
1.3.6.1.4.1.19046.11.1.1.14.4.1.6ColumnadapterNetworkPortNoread-onlymandatoryThe Port No. of this network port in the network function.
1.3.6.1.4.1.19046.11.1.1.14.4.1.7ColumnadapterNetworkPortMaxDataSizeread-onlymandatoryThe Port Max Data Size of this network port in the network function.
1.3.6.1.4.1.19046.11.1.1.14.4.1.8ColumnadapterNetworkPortPermanentAddressread-onlymandatoryThe Permanent Address of a particular network port.
1.3.6.1.4.1.19046.11.1.1.14.4.1.9ColumnadapterNetworkPortNetworkAddressread-onlymandatoryThe Network Address of a particular network port.
1.3.6.1.4.1.19046.11.1.1.14.4.1.10ColumnadapterNetworkPortLinkTechnologyread-onlymandatoryThe Link Technology of a particular network port.
1.3.6.1.4.1.19046.11.1.1.14.4.1.11ColumnadapterNetworkPortvNICModeread-onlymandatoryIf the logical port vNIC mode is Virtual Fabric mode, Switch Independent mode, or Unified Fabric Protocol mode, this column returns 1(enabled), otherwise, the …
1.3.6.1.4.1.19046.11.1.1.14.4.1.12ColumnadapterNetworkPortMaxSpeedread-onlymandatoryThe Maximum Bandwidth in Gbps of a particular network port.
1.3.6.1.4.1.19046.11.1.1.14.4.1.13ColumnadapterNetworkPortProtocolTyperead-onlymandatoryThe Protocol Type of a particular network port.
1.3.6.1.4.1.19046.11.1.1.14.4.1.14ColumnadapterNetworkPortCurrentProtocolread-onlymandatoryThe Current Work Protocol of a particular network port.
1.3.6.1.4.1.19046.11.1.1.14.4.1.15ColumnadapterNetworkPortFCoEPermanentAddressread-onlymandatoryThe FCoE Permanent Address of a particular network port.
1.3.6.1.4.1.19046.11.1.1.14.4.1.16ColumnadapterNetworkPortFCoENetworkAddressread-onlymandatoryThe FCoE Network Address of a particular network port.
1.3.6.1.4.1.19046.11.1.1.14.4.1.17ColumnadapterNetworkPortConnectionTyperead-onlymandatoryThe Connection Type of a particular network port if its current work protocol is FC or FCoE.
1.3.6.1.4.1.19046.11.1.1.14.4.1.18ColumnadapterNetworkPortRoleread-onlymandatoryThe Port Role of a particular network port if its current work protocol is FC or FCoE.
1.3.6.1.4.1.19046.11.1.1.14.4.1.19ColumnadapterNetworkPortTargetRelativePortNoread-onlymandatoryThe Target Relative Port No. of a particular network port if its current work protocol is FC or FCoE.
1.3.6.1.4.1.19046.11.1.1.14.4.1.20ColumnadapterNetworkPortPhyPortLinkStatusread-onlymandatoryThe Physical Port Link Status in the network function for this port.
1.3.6.1.4.1.19046.11.1.1.14.4.1.21ColumnadapterNetworkPortPhyPortLinkSpeedread-onlymandatoryThe Physical Port Link Speed in the network function for this port.
1.3.6.1.4.1.19046.11.1.1.14.5TableadapterGPUFunctionTablenot-accessiblemandatoryTable of GPU Function information.
1.3.6.1.4.1.19046.11.1.1.14.5.1RowadapterGPUFunctionEntrynot-accessiblemandatoryGPU function information entry.
1.3.6.1.4.1.19046.11.1.1.14.5.1.1ColumnadapterGPUFunctionIndexread-onlymandatoryThis column is used to identify a particular GPU function.
1.3.6.1.4.1.19046.11.1.1.14.5.1.2ColumnadapterGPUFunctionGpuVPDProdNameread-onlymandatoryThe Product Name and PFA of a particular GPU function and PFA is in HEX.
1.3.6.1.4.1.19046.11.1.1.14.5.1.3ColumnadapterGPUFunctionAdapterVPDProdNameread-onlymandatoryThe Product Name of a particular adapter providing this function. And if the Product Name contains PFA, PFA is in HEX.
1.3.6.1.4.1.19046.11.1.1.14.5.1.4ColumnadapterGPUFunctionGpuVPDManufacturerread-onlymandatoryThe Manufacturer of a particular GPU function.
1.3.6.1.4.1.19046.11.1.1.14.5.1.5ColumnadapterGPUFunctionGpuVPDUUIDread-onlymandatoryThe UUID of a particular GPU function.
1.3.6.1.4.1.19046.11.1.1.14.5.1.6ColumnadapterGPUFunctionGpuVPDModelread-onlymandatoryThe Model of a particular GPU function.
1.3.6.1.4.1.19046.11.1.1.14.5.1.7ColumnadapterGPUFunctionGpuVPDSerialNoread-onlymandatoryThe Serial No. of a particular GPU function.
1.3.6.1.4.1.19046.11.1.1.14.5.1.8ColumnadapterGPUFunctionGpuVPDFRUNoread-onlymandatoryThe FRU No. of a particular GPU function.
1.3.6.1.4.1.19046.11.1.1.14.5.1.9ColumnadapterGPUFunctionGpuVPDPartNoread-onlymandatoryThe Part No. of a particular GPU function.
1.3.6.1.4.1.19046.11.1.1.14.5.1.10ColumnadapterGPUFunctionFoDUIDread-onlymandatoryThe FoD UID of a particular GPU function.
1.3.6.1.4.1.19046.11.1.1.14.5.1.11ColumnadapterGPUFunctionSupportHotPlugread-onlymandatoryIndicates whether the GPU function supports hot plug.
1.3.6.1.4.1.19046.11.1.1.14.5.1.12ColumnadapterGPUFunctionVideoMemorySizeread-onlymandatoryThe Video Memory Size of a particular GPU function.
1.3.6.1.4.1.19046.11.1.1.14.5.1.13ColumnadapterGPUFunctionVideoMemoryTyperead-onlymandatoryThe Video Memory Type of a particular GPU function.
1.3.6.1.4.1.19046.11.1.1.14.5.1.14ColumnadapterGPUFunctionChipNumberread-onlymandatoryThe Chip Number of a particular GPU function.
1.3.6.1.4.1.19046.11.1.1.14.5.1.15ColumnadapterGPUFunctionMaxDataWidthread-onlymandatoryThe Maximum Data Width in Gbps of a particular GPU funtion.
1.3.6.1.4.1.19046.11.1.1.14.5.1.16ColumnadapterGPUFunctionPackageTyperead-onlymandatoryThe Package Type of a particular GPU function.
1.3.6.1.4.1.19046.11.1.1.14.5.1.17ColumnadapterGPUFunctionPCIBusNoread-onlymandatoryThe PCI Bus No. of a particular GPU function.
1.3.6.1.4.1.19046.11.1.1.14.5.1.18ColumnadapterGPUFunctionPCIDevNoread-onlymandatoryThe PCI Device No. of a particular GPU function.
1.3.6.1.4.1.19046.11.1.1.14.5.1.19ColumnadapterGPUFunctionPCIFuncNoread-onlymandatoryThe PCI Function No. of a particular GPU function.
1.3.6.1.4.1.19046.11.1.1.14.5.1.20ColumnadapterGPUFunctionPCIVendorIdread-onlymandatoryThe PCI Vendor ID of a particular GPU function.
1.3.6.1.4.1.19046.11.1.1.14.5.1.21ColumnadapterGPUFunctionPCIDevIdread-onlymandatoryThe PCI Device ID of a particular GPU function.
1.3.6.1.4.1.19046.11.1.1.14.5.1.22ColumnadapterGPUFunctionPCIDevTyperead-onlymandatoryThe PCI Device Type of a particular GPU function.
1.3.6.1.4.1.19046.11.1.1.14.5.1.23ColumnadapterGPUFunctionPCIRevIdread-onlymandatoryThe PCI Revision ID of a particular GPU function.
1.3.6.1.4.1.19046.11.1.1.14.5.1.24ColumnadapterGPUFunctionPCISubVendorIdread-onlymandatoryThe PCI Subsystem Vendor ID of a particular GPU function.
1.3.6.1.4.1.19046.11.1.1.14.5.1.25ColumnadapterGPUFunctionPCISubDevIdread-onlymandatoryThe PCI Subsystem Device ID of a particular GPU function.
1.3.6.1.4.1.19046.11.1.1.14.5.1.26ColumnadapterGPUFunctionPCISlotDesignationread-onlymandatoryThe PCI Slot Designation of a particular GPU function.
1.3.6.1.4.1.19046.11.1.1.14.6TableadapterGPUChipTablenot-accessiblemandatoryTable of Chips of GPU Function information.
1.3.6.1.4.1.19046.11.1.1.14.6.1RowadapterGPUChipEntrynot-accessiblemandatoryGPU function chip information entry.
1.3.6.1.4.1.19046.11.1.1.14.6.1.1ColumnadapterGPUChipIndexread-onlymandatoryThis column is used to identify a particular GPU chip
1.3.6.1.4.1.19046.11.1.1.14.6.1.2ColumnadapterGPUChipGpuVPDProdNameread-onlymandatoryThe Product Name and PFA of the GPU function for this chip and PFA is in HEX.
1.3.6.1.4.1.19046.11.1.1.14.6.1.3ColumnadapterGPUChipNoread-onlymandatoryThe Index of the GPU chip in the GPU adapter.
1.3.6.1.4.1.19046.11.1.1.14.6.1.4ColumnadapterGPUChipNameread-onlymandatoryThe Name of a particular GPU chip.
1.3.6.1.4.1.19046.11.1.1.14.6.1.5ColumnadapterGPUChipFamilyread-onlymandatoryThe Family Name of a particular GPU chip.
1.3.6.1.4.1.19046.11.1.1.14.6.1.6ColumnadapterGPUChipManufacturerread-onlymandatoryThe Manufacturer of a particular GPU chip.
1.3.6.1.4.1.19046.11.1.1.14.6.1.7ColumnadapterGPUChipCoresEnabledread-onlymandatoryIndicates whether enable cores of a particular GPU chip.
1.3.6.1.4.1.19046.11.1.1.14.6.1.8ColumnadapterGPUChipMaxClockSpeedread-onlymandatoryThe Maximum Clock Speed in MHz of a particular GPU chip.
1.3.6.1.4.1.19046.11.1.1.14.6.1.9ColumnadapterGPUChipExtBusClockSpeedread-onlymandatoryThe External Bus Clock Speed in MHz of a particular GPU chip.
1.3.6.1.4.1.19046.11.1.1.14.6.1.10ColumnadapterGPUChipAddressWidthread-onlymandatoryThe Address Width of a particular GPU chip.
1.3.6.1.4.1.19046.11.1.1.14.6.1.11ColumnadapterGPUChipDataWidthread-onlymandatoryThe Data Width of a particular GPU chip.
1.3.6.1.4.1.19046.11.1.1.14.6.1.12ColumnadapterGPUChipFormFactorread-onlymandatoryThe Form Factor of a particular GPU chip.
1.3.6.1.4.1.19046.11.1.1.14.6.1.13ColumnadapterGPUChipModelread-onlymandatoryThe Model of a particular GPU chip.
1.3.6.1.4.1.19046.11.1.1.14.6.1.14ColumnadapterGPUChipSerialNoread-onlymandatoryThe Serial No. of a particular GPU chip.
1.3.6.1.4.1.19046.11.1.1.14.6.1.15ColumnadapterGPUChipFRUNoread-onlymandatoryThe FRU No. of a particular GPU chip.
1.3.6.1.4.1.19046.11.1.1.14.6.1.16ColumnadapterGPUChipPartNoread-onlymandatoryThe Part No. of a particular GPU chip.
1.3.6.1.4.1.19046.11.1.1.14.6.1.17ColumnadapterGPUChipUniqueIDread-onlymandatoryThe Unique ID of a particular GPU chip.
1.3.6.1.4.1.19046.11.1.1.14.7TableadapterRAIDFunctionTablenot-accessiblemandatoryTable of RAID Function information.
1.3.6.1.4.1.19046.11.1.1.14.7.1RowadapterRAIDFunctionEntrynot-accessiblemandatoryRAID function information entry.
1.3.6.1.4.1.19046.11.1.1.14.7.1.1ColumnadapterRAIDFunctionIndexread-onlymandatoryThis column is used to identify a particular RAID function.
1.3.6.1.4.1.19046.11.1.1.14.7.1.2ColumnadapterRAIDFunctionRaidVPDProdNameread-onlymandatoryThe Product Name and PFA of a particular RAID function and PFA is in HEX.
1.3.6.1.4.1.19046.11.1.1.14.7.1.3ColumnadapterRAIDFunctionAdapterVPDProdNameread-onlymandatoryThe Product Name of a particular adapter providing this function. And if the Product Name contains PFA, PFA is in HEX.
1.3.6.1.4.1.19046.11.1.1.14.7.1.4ColumnadapterRAIDFunctionRaidVPDManufacturerread-onlymandatoryThe Manufacturer of a particular RAID function.
1.3.6.1.4.1.19046.11.1.1.14.7.1.5ColumnadapterRAIDFunctionRaidVPDUUIDread-onlymandatoryThe UUID of a particular RAID function.
1.3.6.1.4.1.19046.11.1.1.14.7.1.6ColumnadapterRAIDFunctionRaidVPDModelread-onlymandatoryThe Model of a particular RAID function.
1.3.6.1.4.1.19046.11.1.1.14.7.1.7ColumnadapterRAIDFunctionRaidVPDSerialNoread-onlymandatoryThe Serial No. of a particular RAID function.
1.3.6.1.4.1.19046.11.1.1.14.7.1.8ColumnadapterRAIDFunctionRaidVPDFRUNoread-onlymandatoryThe FRU No. of a particular RAID function.
1.3.6.1.4.1.19046.11.1.1.14.7.1.9ColumnadapterRAIDFunctionRaidVPDPartNoread-onlymandatoryThe Part No. of a particular RAID function.
1.3.6.1.4.1.19046.11.1.1.14.7.1.10ColumnadapterRAIDFunctionFoDUIDread-onlymandatoryThe FoD UID of a particular RAID function.
1.3.6.1.4.1.19046.11.1.1.14.7.1.11ColumnadapterRAIDFunctionSupportHotPlugread-onlymandatoryIndicates whether the RAID function supports hot plug.
1.3.6.1.4.1.19046.11.1.1.14.7.1.12ColumnadapterRAIDFunctionMaxDataWidthread-onlymandatoryThe Maximum Data Width in Gbps of a particular RAID funtion.
1.3.6.1.4.1.19046.11.1.1.14.7.1.13ColumnadapterRAIDFunctionPackageTyperead-onlymandatoryThe Package Type of a particular RAID function.
1.3.6.1.4.1.19046.11.1.1.14.7.1.14ColumnadapterRAIDFunctionPCIBusNoread-onlymandatoryThe PCI Bus No. of a particular RAID function.
1.3.6.1.4.1.19046.11.1.1.14.7.1.15ColumnadapterRAIDFunctionPCIDevNoread-onlymandatoryThe PCI Device No. of a particular RAID function.
1.3.6.1.4.1.19046.11.1.1.14.7.1.16ColumnadapterRAIDFunctionPCIFuncNoread-onlymandatoryThe PCI Function No. of a particular RAID function.
1.3.6.1.4.1.19046.11.1.1.14.7.1.17ColumnadapterRAIDFunctionPCIVendorIdread-onlymandatoryThe PCI Vendor ID of a particular RAID function.
1.3.6.1.4.1.19046.11.1.1.14.7.1.18ColumnadapterRAIDFunctionPCIDevIdread-onlymandatoryThe PCI Device ID of a particular RAID function.
1.3.6.1.4.1.19046.11.1.1.14.7.1.19ColumnadapterRAIDFunctionPCIDevTyperead-onlymandatoryThe PCI Device Type of a particular RAID function.
1.3.6.1.4.1.19046.11.1.1.14.7.1.20ColumnadapterRAIDFunctionPCIRevIdread-onlymandatoryThe PCI Revision ID of a particular RAID function.
1.3.6.1.4.1.19046.11.1.1.14.7.1.21ColumnadapterRAIDFunctionPCISubVendorIdread-onlymandatoryThe PCI Subsystem Vendor ID of a particular RAID function.
1.3.6.1.4.1.19046.11.1.1.14.7.1.22ColumnadapterRAIDFunctionPCISubDevIdread-onlymandatoryThe PCI Subsystem Device ID of a particular RAID function.
1.3.6.1.4.1.19046.11.1.1.14.7.1.23ColumnadapterRAIDFunctionPCISlotDesignationread-onlymandatoryThe PCI Slot Designation of a particular RAID function.
1.3.6.1.4.1.19046.11.1.1.14.8TableadapterFirmwareTablenot-accessiblemandatoryTable of PCI Function Firmware information.
1.3.6.1.4.1.19046.11.1.1.14.8.1RowadapterFirmwareEntrynot-accessiblemandatoryAdapter Firmware Entry.
1.3.6.1.4.1.19046.11.1.1.14.8.1.1ColumnadapterFwIndexread-onlymandatoryThis column is used to identify a particular function firmware.
1.3.6.1.4.1.19046.11.1.1.14.8.1.2ColumnadapterFwFunctionVPDProdNameread-onlymandatoryThe Product Name and PFA of a particular function for this firmware and PFA is in HEX.
1.3.6.1.4.1.19046.11.1.1.14.8.1.3ColumnadapterFwNameread-onlymandatoryThe name of a particular PCI function firmware.
1.3.6.1.4.1.19046.11.1.1.14.8.1.4ColumnadapterFwClassificationread-onlymandatoryThe classification of a particular PCI function firmware.
1.3.6.1.4.1.19046.11.1.1.14.8.1.5ColumnadapterFwDescriptionread-onlymandatoryThe description of a particular PCI function firmware.
1.3.6.1.4.1.19046.11.1.1.14.8.1.6ColumnadapterFwManufactureread-onlymandatoryThe manufacturer of a particular PCI function firmware.
1.3.6.1.4.1.19046.11.1.1.14.8.1.7ColumnadapterFwVersionread-onlymandatoryThe version of a particular PCI function firmware.
1.3.6.1.4.1.19046.11.1.1.14.8.1.8ColumnadapterFwReleaseDateread-onlymandatoryThe release date of a particular PCI function firmware.
1.3.6.1.4.1.19046.11.1.1.14.8.1.9ColumnadapterFwSoftwareIDread-onlymandatoryThe Software ID of a particular PCI function firmware.
1.3.6.1.4.1.19046.11.1.2NodeerrorLogs
1.3.6.1.4.1.19046.11.1.2.1NodeeventLog
1.3.6.1.4.1.19046.11.1.2.1.1TableeventLogTablenot-accessiblemandatoryTable of event logs. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.2.1.1.1RoweventLogEntrynot-accessiblemandatoryEvent log entries. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.2.1.1.1.1ColumneventLogIndexread-onlymandatoryEvent log index number. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.2.1.1.1.2ColumneventLogStringread-onlymandatoryContains a string of information to detail the event. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.2.1.1.1.3ColumneventLogSeverityread-onlymandatoryContains a information to detail the severity of the event. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.2.1.1.1.4ColumneventLogDateread-onlymandatoryThe Date of the Event occured. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.2.1.1.1.5ColumneventLogTimeread-onlymandatoryThe Time of the Event occured. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.19046.11.1.3NodeconfigureSP
1.3.6.1.4.1.19046.11.1.3.1NoderemoteAccessConfig
1.3.6.1.4.1.19046.11.1.3.1.1NodegeneralRemoteCfg
1.3.6.1.4.1.19046.11.1.3.1.1.1ScalarremoteAlertRetryDelayread-onlymandatoryNumber in seconds to delay between retries if sending a remote alert is unsuccessful.
1.3.6.1.4.1.19046.11.1.3.1.1.2ScalarremoteAlertRetryCountread-onlymandatoryNumber of additional times a remote alert will be retried if not succesfully sent. A value of zero indicates no retries will be attempted.
1.3.6.1.4.1.19046.11.1.3.1.1.3ScalarremoteAlertEntryDelayread-onlymandatoryNumber in seconds to delay between entries if sending a remote alert is unsuccessful.
1.3.6.1.4.1.19046.11.1.3.1.1.4ScalarsnmpCriticalAlertsread-onlymandatoryIf Enabled,criticalAlerts will be sent to SNMP, else critical alerts will not be sent.
1.3.6.1.4.1.19046.11.1.3.1.1.5ScalarsnmpWarningAlertsread-onlymandatoryIf Enabled,warningAlerts will be sent to SNMP , else warning alerts will not be sent.
1.3.6.1.4.1.19046.11.1.3.1.1.6ScalarsnmpSystemAlertsread-onlymandatoryIf Enabled,systemAlerts will be sent to SNMP , else system alerts will not be sent.
1.3.6.1.4.1.19046.11.1.3.1.1.7ScalarremoteAccessTamperDelayread-onlymandatoryNumber in minutes to prohibit a remote login attempt after more than maximum login attempts have failed. The minimum value is 0 and the maximum value is 2880 m…
1.3.6.1.4.1.19046.11.1.3.1.1.8ScalaruserAuthenticationMethodread-onlymandatoryUse this field to specify how users attempting to login should be authenticated. There are two methods: Local authentication. Userid and password are verified …
1.3.6.1.4.1.19046.11.1.3.1.1.9ScalarwebInactivityTimeoutread-onlymandatoryThe amount of time, in minutes, that a user session established with the management server can be inactive before the user is logged out. The minimum value is …
1.3.6.1.4.1.19046.11.1.3.1.1.10NodesnmpAlertFilters
1.3.6.1.4.1.19046.11.1.3.1.1.10.2ScalarsafSpTrapTempCread-onlymandatoryCritical Alert: Temperature threshold exceeded.
1.3.6.1.4.1.19046.11.1.3.1.1.10.3ScalarsafSpTrapVoltCread-onlymandatoryCritical Alert: Voltage threshold exceeded.
1.3.6.1.4.1.19046.11.1.3.1.1.10.4ScalarsafSpTrapPowerCread-onlymandatoryCritical Alert: Power failure.
1.3.6.1.4.1.19046.11.1.3.1.1.10.5ScalarsafSpTrapHdCread-onlymandatoryCritical Alert: Hard disk drive failure.
1.3.6.1.4.1.19046.11.1.3.1.1.10.6ScalarsafSpTrapFanCread-onlymandatoryCritical Alert: Single Fan failure.
1.3.6.1.4.1.19046.11.1.3.1.1.10.7ScalarsafSpTrapIhcCread-onlymandatoryCritical Alert: Incompatible hardware configuration.
1.3.6.1.4.1.19046.11.1.3.1.1.10.8ScalarsafSpTrapCPUCread-onlymandatoryCritical Alert: CPU Error.
1.3.6.1.4.1.19046.11.1.3.1.1.10.9ScalarsafSpTrapMemoryCread-onlymandatoryCritical Alert: Memory Error.
1.3.6.1.4.1.19046.11.1.3.1.1.10.10ScalarsafSpTrapRdpsCread-onlymandatoryCritical Alert: Redundant Power Supply failure.
1.3.6.1.4.1.19046.11.1.3.1.1.10.11ScalarsafSpTrapHardwareCread-onlymandatoryCritical Alert: Other Failure - refer to Message ID for specific condition.
1.3.6.1.4.1.19046.11.1.3.1.1.10.12ScalarsafSpTrapRdpsNread-onlymandatoryNon-Critical Alert: Redundant Power Supply failure.
1.3.6.1.4.1.19046.11.1.3.1.1.10.13ScalarsafSpTrapTempNread-onlymandatoryNon-Critical Alert: Temperature threshold exceeded.
1.3.6.1.4.1.19046.11.1.3.1.1.10.14ScalarsafSpTrapVoltNread-onlymandatoryNon-Critical Alert: Voltage threshold exceeded.
1.3.6.1.4.1.19046.11.1.3.1.1.10.15ScalarsafSpTrapPowerNread-onlymandatoryNon-Critical Alert: Power.
1.3.6.1.4.1.19046.11.1.3.1.1.10.16ScalarsafSpTrapFanNread-onlymandatoryNon-Critical Alert: Fan Error.
1.3.6.1.4.1.19046.11.1.3.1.1.10.17ScalarsafSpTrapCPUNread-onlymandatoryNon-Critical Alert: Memory Error.
1.3.6.1.4.1.19046.11.1.3.1.1.10.18ScalarsafSpTrapMemoryNread-onlymandatoryNon-Critical Alert: Memory Error.
1.3.6.1.4.1.19046.11.1.3.1.1.10.19ScalarsafSpTrapHardwareNread-onlymandatoryNon-Critical Alert: Warning - refer to Message ID for specific condition.
1.3.6.1.4.1.19046.11.1.3.1.1.10.20ScalarsafSpTrapRLoginread-onlymandatorySev-Off Alert: Event Remote Login.
1.3.6.1.4.1.19046.11.1.3.1.1.10.21ScalarsafSpTrapOsToSread-onlymandatorySystem Alert: OS Timeout value exceeded.
1.3.6.1.4.1.19046.11.1.3.1.1.10.22ScalarsafSpTrapAppSread-onlymandatorySystem Alert: Application Alert. Refer to Message ID for specific condition.
1.3.6.1.4.1.19046.11.1.3.1.1.10.23ScalarsafSpTrapPowerSread-onlymandatorySystem Alert: Power on or off.
1.3.6.1.4.1.19046.11.1.3.1.1.10.24ScalarsafSpTrapBootSread-onlymandatorySystem Alert: System Boot Failure.
1.3.6.1.4.1.19046.11.1.3.1.1.10.25ScalarsafSpTrapLdrToSread-onlymandatorySystem Alert: OS Loader Timeout.
1.3.6.1.4.1.19046.11.1.3.1.1.10.26ScalarsafSpTrapPFASread-onlymandatorySystem Alert: Predictive Failure Analysis(PFA) information.
1.3.6.1.4.1.19046.11.1.3.1.1.10.27ScalarsafSpTrapSysLogSread-onlymandatorySystem Alert: System Log 75% full.
1.3.6.1.4.1.19046.11.1.3.1.1.10.28ScalarsafSpTrapNwChangeSread-onlymandatorySystem Alert: Network change notification.
1.3.6.1.4.1.19046.11.1.3.1.1.20NodecustomSecuritySettings
1.3.6.1.4.1.19046.11.1.3.1.1.20.1ScalarpasswordExpirationWarningPeriodread-onlymandatoryThe amount of time, in days, before password expiration that users will begin to receive warnings about the impending expiration of the user password. The mini…
1.3.6.1.4.1.19046.11.1.3.1.1.20.2ScalarpasswordExpirationPeriodread-onlymandatoryThe amount of time, in days, that a user may use a password before it must be changed. Smaller values reduce the amount of time for attackers to guess password…
1.3.6.1.4.1.19046.11.1.3.1.1.20.3ScalarminimumPasswordReuseCycleread-onlymandatoryThe minimum number of the times that a user must enter a unique password before the user can start to reuse passwords. A higher number enhances security. The m…
1.3.6.1.4.1.19046.11.1.3.1.1.20.5ScalarminimumPasswordLengthread-onlymandatoryThe minimum number of characters that can be used to specify a valid password. The minimum value is 8 characters and the maximum value is 20 characters. The de…
1.3.6.1.4.1.19046.11.1.3.1.1.20.6ScalardefaultAdminPasswordExpiredread-onlymandatoryA value of 1 means that the factory default 'USERID' account password must be changed on next login. A value of 0 means that there is no such requirement. The …
1.3.6.1.4.1.19046.11.1.3.1.1.20.8ScalarchangePasswordFirstAccessread-onlymandatoryA value of 1 means that a user is required to change the password when the user logs in to the management server for the first time. A value of 0 means no such…
1.3.6.1.4.1.19046.11.1.3.1.1.20.9ScalaraccountLockoutPeriodread-onlymandatoryThe minimum about of time, in minutes, that must pass before a user that was locked out can attempt to log back in again. The minimum value is 0 and the maximu…
1.3.6.1.4.1.19046.11.1.3.1.1.20.10ScalarmaxLoginFailuresread-onlymandatoryThe maximum number of times that a user can attempt to log in with an incorrect password before the user account is locked out. The number specified for the lo…
1.3.6.1.4.1.19046.11.1.3.1.1.20.11ScalarpasswordChangeIntervalread-onlymandatoryThe minimum about of time, in hours, that must elapse before a user may change a password again after it has been changed once. The value specified for this se…
1.3.6.1.4.1.19046.11.1.3.1.2NodeserialPortCfg
1.3.6.1.4.1.19046.11.1.3.1.2.1ScalarportBaudread-onlymandatoryBaud rate for the serial port.
1.3.6.1.4.1.19046.11.1.3.1.2.2ScalarportParityread-onlymandatoryParity setting for the serial port.
1.3.6.1.4.1.19046.11.1.3.1.2.3NodeserialRedirect
1.3.6.1.4.1.19046.11.1.3.1.2.3.1ScalarenterCLIkeySeqread-onlymandatoryThis is the keystroke sequence used to enter the CLI. This sequence must have at least one character. The caret symbol (^) has a special meaning in this sequen…
1.3.6.1.4.1.19046.11.1.3.1.2.4ScalarportStopBitsread-onlymandatoryNumber of stop bits for the serial port.
1.3.6.1.4.1.19046.11.1.3.1.2.18ScalarportCLImoderead-onlymandatoryUse this field to select the CLI (command line interface) mode for this port. The CLI mode disablies serial redirect, or pecifies the type of keystroke sequenc…
1.3.6.1.4.1.19046.11.1.3.1.3NoderemoteAlertIds
1.3.6.1.4.1.19046.11.1.3.1.3.1TableremoteAlertIdsTablenot-accessiblemandatoryTable of remote alert entries. This table lets you configure remote alert recipients. You can define up to 12 unique recipients.
1.3.6.1.4.1.19046.11.1.3.1.3.1.1RowremoteAlertIdsEntrynot-accessiblemandatoryRemote alert entries.
1.3.6.1.4.1.19046.11.1.3.1.3.1.1.1ColumnremoteAlertIdEntryIndexread-onlymandatoryIndex for remote alert entry.
1.3.6.1.4.1.19046.11.1.3.1.3.1.1.2ColumnremoteAlertIdEntryStatusread-onlymandatoryIf enabled alerts will be sent to this alert recipient else alerts will not be sent.
1.3.6.1.4.1.19046.11.1.3.1.3.1.1.3ColumnremoteAlertIdEntryNameread-onlymandatoryA null terminated string that contains a text description of this entry.
1.3.6.1.4.1.19046.11.1.3.1.3.1.1.4ColumnremoteAlertIdEmailAddrread-onlymandatoryA null terminated string that contains a E-Mail Address. For example '[email protected]'. Used only for a E-mail over Lan.
1.3.6.1.4.1.19046.11.1.3.1.3.1.1.5ColumnremoteAlertIdEntryCriticalAlertread-onlymandatoryIf Enabled,criticalAlerts will be sent to this remote alert receipient,else critical alerts will not be sent.
1.3.6.1.4.1.19046.11.1.3.1.3.1.1.6ColumnremoteAlertIdEntryWarningAlertread-onlymandatoryIf Enabled,warningAlerts will be sent to this remote alert receipient,else warningAlerts will not be sent.
1.3.6.1.4.1.19046.11.1.3.1.3.1.1.7ColumnremoteAlertIdEntrySystemAlertread-onlymandatoryIf Enabled,systemAlerts will be sent to this remote alert receipient,else systemAlerts will not be sent.
1.3.6.1.4.1.19046.11.1.3.1.3.1.1.8ColumnremoteAlertIdEntryAuditAlertread-onlymandatoryIf Enabled,systemAlerts will be sent to this remote alert receipient,else systemAlerts will not be sent.
1.3.6.1.4.1.19046.11.1.3.1.3.1.1.9ColumnremoteAlertIdEntryAttachmentsToEmailAlertsread-onlymandatoryIndicates if the event log should be attached to a email alert.
1.3.6.1.4.1.19046.11.1.3.1.3.1.1.10ColumnremoteAlertIdEntrySyslogPortAssignmentread-onlymandatorySyslog port number.
1.3.6.1.4.1.19046.11.1.3.1.3.1.1.11ColumnremoteAlertIdEntrySyslogHostnameread-onlymandatorySyslog hostname or IP address.
1.3.6.1.4.1.19046.11.1.3.1.3.1.1.12ColumnremoteAlertIdEntryTyperead-onlymandatoryAlert recipient type.
1.3.6.1.4.1.19046.11.1.3.1.3.2TableremoteAlertFiltersTablenot-accessiblemandatoryTable of Alert Filters. The entries (rows) in this table correspond 1-1 with the entries in the remoteAlertIdsTable. They are correlated by index.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1RowremoteAlertFiltersEntrynot-accessiblemandatoryRemote Filters entries.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.1ColumnrafIndexread-onlymandatoryIndex for User Authority Level entry.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.2ColumnrafSpTrapTempCread-onlymandatoryCritical Alert: Temperature threshold exceeded.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.3ColumnrafSpTrapVoltCread-onlymandatoryCritical Alert: Voltage threshold exceeded.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.4ColumnrafSpTrapPowerCread-onlymandatoryCritical Alert: Power failure.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.5ColumnrafSpTrapHdCread-onlymandatoryCritical Alert: Hard disk drive failure.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.6ColumnrafSpTrapFanCread-onlymandatoryCritical Alert: Single Fan failure.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.7ColumnrafSpTrapIhcCread-onlymandatoryCritical Alert: Incompatible hardware configuration.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.8ColumnrafSpTrapCPUCread-onlymandatoryCritical Alert: CPU Error.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.9ColumnrafSpTrapMemoryCread-onlymandatoryCritical Alert: Memory Error.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.10ColumnrafSpTrapRdpsCread-onlymandatoryCritical Alert: Redundant Power Supply failure.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.11ColumnrafSpTrapHardwareCread-onlymandatoryCritical Alert: Other Failure - refer to Message ID for specific condition.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.12ColumnrafSpTrapRdpsNread-onlymandatoryNon-Critical Alert: Redundant Power Supply failure.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.13ColumnrafSpTrapTempNread-onlymandatoryNon-Critical Alert: Temperature threshold exceeded.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.14ColumnrafSpTrapVoltNread-onlymandatoryNon-Critical Alert: Voltage threshold exceeded.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.15ColumnrafSpTrapPowerNread-onlymandatoryNon-Critical Alert: Power.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.16ColumnrafSpTrapFanNread-onlymandatoryNon-Critical Alert: Fan Error.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.17ColumnrafSpTrapCPUNread-onlymandatoryNon-Critical Alert: Memory Error.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.18ColumnrafSpTrapMemoryNread-onlymandatoryNon-Critical Alert: Memory Error.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.19ColumnrafSpTrapHardwareNread-onlymandatoryNon-Critical Alert: Warning - refer to Message ID for specific condition.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.20ColumnrafSpTrapRLoginread-onlymandatorySev-Off Alert: Event Remote Login.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.21ColumnrafSpTrapOsToSread-onlymandatorySystem Alert: OS Timeout value exceeded.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.22ColumnrafSpTrapAppSread-onlymandatorySystem Alert: Application Alert. Refer to Message ID for specific condition.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.23ColumnrafSpTrapPowerSread-onlymandatorySystem Alert: Power On or Off.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.24ColumnrafSpTrapBootSread-onlymandatorySystem Alert: System Boot Failure.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.25ColumnrafSpTrapLdrToSread-onlymandatorySystem Alert: OS Loader Timeout.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.26ColumnrafSpTrapPFASread-onlymandatorySystem Alert: Predictive Failure Analysis(PFA) information.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.27ColumnrafSpTrapSysLogSread-onlymandatorySystem Alert: System Log 75% full.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.28ColumnrafSpTrapNwChangeSread-onlymandatorySystem Alert: Network change notification.
1.3.6.1.4.1.19046.11.1.3.1.3.2.1.29ColumnrafSpTrapAllAuditSread-onlymandatorySystem Alert: All Audit Events notification.
1.3.6.1.4.1.19046.11.1.3.1.4NoderemoteAccessIds
1.3.6.1.4.1.19046.11.1.3.1.4.1TableremoteAccessIdsTablenot-accessiblemandatoryTable of remote access profiles. This table lets you to configure all login profiles. You can define up to 12 unique profiles. Note: By default, the remote sup…
1.3.6.1.4.1.19046.11.1.3.1.4.1.1RowremoteAccessIdsEntrynot-accessiblemandatoryRemote access entries.
1.3.6.1.4.1.19046.11.1.3.1.4.1.1.1ColumnremoteAccessIdEntryIndexread-onlymandatoryIndex for Remote access entry.
1.3.6.1.4.1.19046.11.1.3.1.4.1.1.2ColumnremoteAccessIdEntryUserIdread-onlymandatoryRemote access entry null terminated string that contains the user-id. This can only be modified from blank to non-blank, then back to blank.
1.3.6.1.4.1.19046.11.1.3.1.4.1.1.3ColumnremoteAccessIdEntryUserPwdLeftDaysread-onlymandatoryleft days before password expired for selected user
1.3.6.1.4.1.19046.11.1.3.1.4.2TableremoteAccessUserAuthorityLevelTablenot-accessiblemandatoryTable of user authority level profiles.
1.3.6.1.4.1.19046.11.1.3.1.4.2.1RowremoteAccessUserAuthorityLevelEntrynot-accessiblemandatoryUser authority level entries.
1.3.6.1.4.1.19046.11.1.3.1.4.2.1.1ColumnualIndexread-onlymandatoryIndex for User Authority Level entry.
1.3.6.1.4.1.19046.11.1.3.1.4.2.1.2ColumnualIdread-onlymandatoryUser ID
1.3.6.1.4.1.19046.11.1.3.1.4.2.1.3ColumnualSupervisorread-onlymandatoryUser has no restrictions.
1.3.6.1.4.1.19046.11.1.3.1.4.2.1.4ColumnualReadOnlyread-onlymandatoryUser has only read-only access, and cannot perform any save, modify, clear, or state affecting operations (eg. restart XCC, restore defaults, upgrade the firmw…
1.3.6.1.4.1.19046.11.1.3.1.4.2.1.5ColumnualAccountManagementread-onlymandatoryIt is custom user authority level. User can add/modify/delete users and change the global login settings in the Login Profiles panel. NOTE: The value is meanin…
1.3.6.1.4.1.19046.11.1.3.1.4.2.1.6ColumnualConsoleAccessread-onlymandatoryIt is custom user authority level. User can access the remote console. NOTE: The value is meaningless for this MIB object if the ualSupervisor or ualReadOnly i…
1.3.6.1.4.1.19046.11.1.3.1.4.2.1.7ColumnualConsoleAndVirtualMediaAccessread-onlymandatoryIt is custom user authority level. User can access both the remote console and the virtual media feature. NOTE: The value is meaningless for this MIB object if…
1.3.6.1.4.1.19046.11.1.3.1.4.2.1.8ColumnualServerPowerAccessread-onlymandatoryIt is custom user authority level. User can access the power on and restart functions for the remote server. These functions are available via the Power/Restar…
1.3.6.1.4.1.19046.11.1.3.1.4.2.1.9ColumnualAllowClearLogread-onlymandatoryIt is custom user authority level. User can clear the event logs. Everyone can look at the event logs, but this particular permission is required to clear the …
1.3.6.1.4.1.19046.11.1.3.1.4.2.1.10ColumnualAdapterBasicConfigread-onlymandatoryIt is custom user authority level. User can modify configuration parameters in the System Settings and Alerts panels. NOTE: The value is meaningless for this M…
1.3.6.1.4.1.19046.11.1.3.1.4.2.1.11ColumnualAdapterNetworkAndSecurityConfigread-onlymandatoryIt is custom user authority level. User can modify configuration parameters in the Security, Network Protocols, Network Interface, Port Assignments, and Serial…
1.3.6.1.4.1.19046.11.1.3.1.4.2.1.12ColumnualAdapterAdvancedConfigread-onlymandatoryIt is custom user authority level. User has no restrictions when configuring the adapter. In addition, the user is said to have administrative access to the XC…
1.3.6.1.4.1.19046.11.1.3.1.5NodegroupProfiles
1.3.6.1.4.1.19046.11.1.3.1.5.1TablegroupIdsTablenot-accessiblemandatoryTable of Group profiles. This table lets you to configure all group profiles. You can define up to 16 unique profiles.
1.3.6.1.4.1.19046.11.1.3.1.5.1.1RowgroupIdsEntrynot-accessiblemandatoryGroup ID entries.
1.3.6.1.4.1.19046.11.1.3.1.5.1.1.1ColumngroupIndexread-onlymandatoryIndex for Group IDs entry.
1.3.6.1.4.1.19046.11.1.3.1.5.1.1.2ColumngroupIdread-onlymandatoryGroup ID. It is a null terminated string that contains the group-id. It must not be a duplicate of any previously configured ones.
1.3.6.1.4.1.19046.11.1.3.1.5.1.1.3ColumngroupRoleread-onlymandatoryGroup Role. It indicates if the group has supervisor, operator, or custom access.
1.3.6.1.4.1.19046.11.1.3.1.5.2TablegroupRBSroleTablenot-accessiblemandatoryTable of Group Role profiles.
1.3.6.1.4.1.19046.11.1.3.1.5.2.1RowgroupRBSroleEntrynot-accessiblemandatoryGroup Role entries.
1.3.6.1.4.1.19046.11.1.3.1.5.2.1.1ColumngroupRBSroleIndexread-onlymandatoryIndex for Group Role entry.
1.3.6.1.4.1.19046.11.1.3.1.5.2.1.2ColumngroupRBSroleIdread-onlymandatoryGroup ID
1.3.6.1.4.1.19046.11.1.3.1.5.2.1.3ColumngroupRBSSupervisorread-onlymandatoryGroup has no restrictions.
1.3.6.1.4.1.19046.11.1.3.1.5.2.1.4ColumngroupRBSOperatorread-onlymandatoryGroup has read-only access, and cannot perform any save, modify, clear, or state affecting operations (e.g. restart XCC, restore defaults, upgrade the firmware…
1.3.6.1.4.1.19046.11.1.3.1.5.2.1.5ColumngroupRBSNetworkSecurityread-onlymandatoryGroup can modify the configuration in the Security, Network Protocols, Network Interface, Port Assignments, and Serial Port panels.
1.3.6.1.4.1.19046.11.1.3.1.5.2.1.6ColumngroupRBSUserAccountManagementread-onlymandatoryGroup can add/modify/delete users and change the Global Login Settings in the Login Profiles panel.
1.3.6.1.4.1.19046.11.1.3.1.5.2.1.7ColumngroupRBSRemoteConsoleAccessread-onlymandatoryGroup can access the remote server console.
1.3.6.1.4.1.19046.11.1.3.1.5.2.1.8ColumngroupRBSRemoteConsoleRemoteDiskAccessread-onlymandatoryGroup can access the remote server console and the remote disk functions for the remote server.
1.3.6.1.4.1.19046.11.1.3.1.5.2.1.9ColumngroupRBSServerPowerRestartAccessread-onlymandatoryGroup can access the power on, restart and server timeout functions for the remote server.
1.3.6.1.4.1.19046.11.1.3.1.5.2.1.10ColumngroupRBSBasicAdapterConfigurationread-onlymandatoryGroup can modify configuration parameters in the System Settings (excluding Contact, Location and Server Timeouts) and Alerts panels.
1.3.6.1.4.1.19046.11.1.3.1.5.2.1.11ColumngroupRBSClearEventLogread-onlymandatoryGroup can clear the event logs. Everyone can look at the event logs, but this particular permission is required to clear the logs.
1.3.6.1.4.1.19046.11.1.3.1.5.2.1.12ColumngroupRBSAdvancedAdapterConfigurationread-onlymandatoryGroup has no restrictions when configuring the adapter. In addition the user is said to have administrative access to the XCC, meaning that the user can also p…
1.3.6.1.4.1.19046.11.1.3.1.6NodesshClientAuth
1.3.6.1.4.1.19046.11.1.3.1.6.1TablesshClientAuthPubKeyTablenot-accessiblemandatoryA table that contains client authentication public key information.
1.3.6.1.4.1.19046.11.1.3.1.6.1.1RowsshClientAuthPubKeyEntrynot-accessiblemandatoryA information list about a particular SSH public key used for client authentication. The primary table index is the same value as the associated remoteAccessId…
1.3.6.1.4.1.19046.11.1.3.1.6.1.1.1ColumnsshClientAuthRemoteAccessIdIndexnot-accessiblemandatoryThe primary table index is the same value as the associated remoteAccessIdEntryIndex used as an index into the remoteAccessIdsTable.
1.3.6.1.4.1.19046.11.1.3.1.6.1.1.2ColumnsshClientAuthPubKeyIndexnot-accessiblemandatoryThe secondary table index used to select one of the client authentication public keys for a particular remote access Id. The index is an integer value from 1 t…
1.3.6.1.4.1.19046.11.1.3.1.6.1.1.3ColumnsshClientAuthPubKeyTyperead-onlymandatoryThe type of the SSH public key represented by this entry.
1.3.6.1.4.1.19046.11.1.3.1.6.1.1.4ColumnsshClientAuthPubKeySizeread-onlymandatoryThe size of the SSH public key represented by this entry.
1.3.6.1.4.1.19046.11.1.3.1.6.1.1.5ColumnsshClientAuthPubKeyFingerprintread-onlymandatoryThe RSA fingerprint of the SSH public key represented by this entry. This value can be used with the SSH client to verify, on the initial connection, that the …
1.3.6.1.4.1.19046.11.1.3.1.6.1.1.6ColumnsshClientAuthPubKeyAcceptFromread-onlymandatoryThis is a filter that describes the set of SSH client IP addresses and host names that can establish SSH connections to the AMM authenticated by the public key…
1.3.6.1.4.1.19046.11.1.3.1.6.2ScalarsshClientAuthPubKeyUnusedread-onlymandatoryThe number of available storage locations that may be used to install additional Client Authentication Public Keys. This number decreases by one when a new key…
1.3.6.1.4.1.19046.11.1.3.2NodespClock
1.3.6.1.4.1.19046.11.1.3.2.1ScalarspClockDateAndTimeSettingread-onlymandatoryDisplay XCC clock date and time setting, The format of the value is month/day/year, hour:minutes:seconds.
1.3.6.1.4.1.19046.11.1.3.2.2ScalarspClockTimezoneSettingread-onlymandatoryDisplay XCC clock Greenwich Mean Time(GMT) offset and Daylight Saving Time(DST) settings. The following table lists GMT offsets and associated DST information.…
1.3.6.1.4.1.19046.11.1.3.3NodespIdentification
1.3.6.1.4.1.19046.11.1.3.3.1ScalarspTxtIdread-onlymandatoryXCC text ID.
1.3.6.1.4.1.19046.11.1.3.3.2ScalarspRoomIDread-onlymandatoryRoom where the system is located.
1.3.6.1.4.1.19046.11.1.3.3.3ScalarspRackIDread-onlymandatoryID for Rack that contains this system.
1.3.6.1.4.1.19046.11.1.3.3.4ScalarspRackUnitPositionread-onlymandatoryPosition within the rack for this system.
1.3.6.1.4.1.19046.11.1.3.3.5ScalarspRackUnitHeightread-onlymandatoryNumber of rack units occupied by this system.
1.3.6.1.4.1.19046.11.1.3.3.6ScalarspRackBladeBayread-onlymandatoryBay number for system contained in a blade chassis.
1.3.6.1.4.1.19046.11.1.3.3.7ScalarspFullPostalAddressread-onlymandatoryA NULL terminated 300 byte string that contains the full postal address for this system.
1.3.6.1.4.1.19046.11.1.3.4NodenetworkConfiguration
1.3.6.1.4.1.19046.11.1.3.4.1NodenetworkInterfaces
1.3.6.1.4.1.19046.11.1.3.4.1.1NodeethernetInterface
1.3.6.1.4.1.19046.11.1.3.4.1.1.1ScalarethernetInterfaceTyperead-onlymandatoryThe type of interface. Indicates 'Ethernet-1'.
1.3.6.1.4.1.19046.11.1.3.4.1.1.2ScalarethernetInterfaceEnabledread-onlymandatoryDisable or enable the interface.
1.3.6.1.4.1.19046.11.1.3.4.1.1.3ScalarethernetInterfaceHostNameread-onlymandatoryContains the 64 byte null terminated DNS host name for this interface.
1.3.6.1.4.1.19046.11.1.3.4.1.1.4ScalarethernetInterfaceIPAddressread-onlymandatoryContains the IP address for the ethernet interface.
1.3.6.1.4.1.19046.11.1.3.4.1.1.5ScalarethernetInterfaceAutoNegotiateread-onlymandatoryIf this is enabled, then we should ignore Speed/Duplex.
1.3.6.1.4.1.19046.11.1.3.4.1.1.6ScalarethernetInterfaceDataRateread-onlymandatorySpecifies the data transfer rate to be used over the ethernet interface 10Mb/100Mb/Auto. Note that the value of this variable is ignored if ethernetInterfaceAu…
1.3.6.1.4.1.19046.11.1.3.4.1.1.7ScalarethernetInterfaceDuplexSettingread-onlymandatorySpecifies the duplex settings for the data transfer rate to be used over the ethernet interface Half/Full/Auto.
1.3.6.1.4.1.19046.11.1.3.4.1.1.8ScalarethernetInterfaceLAAread-onlymandatorySpecifies the locally administered MAC address. The locally administered address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value mu…
1.3.6.1.4.1.19046.11.1.3.4.1.1.9ScalarethernetInterfaceDhcpEnabledread-onlymandatoryDisable or enable DHCP on this interface.
1.3.6.1.4.1.19046.11.1.3.4.1.1.10ScalarethernetInterfaceGatewayIPAddressread-onlymandatoryContains the IP address of the gateway/router for the ethernet interface.
1.3.6.1.4.1.19046.11.1.3.4.1.1.11ScalarethernetInterfaceBIAread-onlymandatorySpecifies the burned-in MAC (BIA) address.
1.3.6.1.4.1.19046.11.1.3.4.1.1.12ScalarethernetInterfaceMTUread-onlymandatoryContains the Maximum Transmission Unit(MTU) for the ethernet interface
1.3.6.1.4.1.19046.11.1.3.4.1.1.13ScalarethernetInterfaceSubnetMaskread-onlymandatoryContains the Subnet Mask for the ethernet interface
1.3.6.1.4.1.19046.11.1.3.4.1.1.14NodedhcpEthernetInterface
1.3.6.1.4.1.19046.11.1.3.4.1.1.14.1ScalardhcpHostNameread-onlymandatoryContains the 64 byte null terminated DNS host name for this interface, assigned by the DHCP server.
1.3.6.1.4.1.19046.11.1.3.4.1.1.14.2ScalardhcpIPAddressread-onlymandatoryContains the IP address for the ehternet interface, assigned by the DHCP server.
1.3.6.1.4.1.19046.11.1.3.4.1.1.14.3ScalardhcpGatewayIPAddressread-onlymandatoryContains the IP address of the gateway/router for the ethernet interface, assigned by the DHCP server.
1.3.6.1.4.1.19046.11.1.3.4.1.1.14.4ScalardhcpSubnetMaskread-onlymandatoryContains the Subnet Mask for the ethernet interface, assigned by the DHCP server.
1.3.6.1.4.1.19046.11.1.3.4.1.1.14.5ScalardhcpDomainNameread-onlymandatoryContains the 64 byte null terminated Domain Name for this interface, assigned by the DHCP server.
1.3.6.1.4.1.19046.11.1.3.4.1.1.14.6ScalardhcpPrimaryDNSServerread-onlymandatoryContains the Primary DNS server, assigned by the DHCP server.
1.3.6.1.4.1.19046.11.1.3.4.1.1.14.7ScalardhcpSecondaryDNSServerread-onlymandatoryContains the Secondary DNS server, assigned by the DHCP server.
1.3.6.1.4.1.19046.11.1.3.4.1.1.14.8ScalardhcpTertiaryDNSServerread-onlymandatoryContains the tertiary DNS server, assigned by the DHCP server.
1.3.6.1.4.1.19046.11.1.3.4.1.1.15ScalarethernetInterfaceVlanread-onlymandatoryIf this is enabled, assign VLAN ID needs to be assigned. NOTE: This is not supported on blades.
1.3.6.1.4.1.19046.11.1.3.4.1.1.16ScalarethernetInterfaceVlanIDread-onlymandatoryContains the VLAN ID for the ethernet interface. NOTE: This is not supported in blades.
1.3.6.1.4.1.19046.11.1.3.4.1.4NodeethernetInterfaceIPv6
1.3.6.1.4.1.19046.11.1.3.4.1.4.2ScalarethernetInterfaceIPv6Enabledread-onlymandatoryThe current IPv6 enabled or disabled state of this XCC. NOTE: If IPv6 address(es) have been configured for one or more interfaces/protocols/services on this XC…
1.3.6.1.4.1.19046.11.1.3.4.1.4.5NodeethernetInterfaceIPv6Config
1.3.6.1.4.1.19046.11.1.3.4.1.4.5.1NodeethernetInterfaceIPv6LocalAddress
1.3.6.1.4.1.19046.11.1.3.4.1.4.5.1.1ScalarethernetInterfaceIPv6LinkLocalAddressread-onlymandatoryThe IPv6 link local IP address for the ethernet interface. NOTE: If ethernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:…
1.3.6.1.4.1.19046.11.1.3.4.1.4.5.2NodeethernetInterfaceIPv6StaticIPConfig
1.3.6.1.4.1.19046.11.1.3.4.1.4.5.2.1ScalarethernetInterfaceIPv6StaticIPConfigEnabledread-onlymandatoryThe IPv6 static IP address enabled or disabled state for the ethernet interface.
1.3.6.1.4.1.19046.11.1.3.4.1.4.5.2.2ScalarethernetInterfaceIPv6StaticIPAddressread-onlymandatoryThe IPv6 static IP address for the ethernet interface. NOTE: If ethernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'.
1.3.6.1.4.1.19046.11.1.3.4.1.4.5.2.3ScalarethernetInterfaceIPv6StaticIPAddressPrefixLenread-onlymandatoryThe IPv6 static IP address prefix length for the ethernet interface. NOTE: If ethernetInterfaceIPv6Enabled is currently disabled, this object has the value 0.
1.3.6.1.4.1.19046.11.1.3.4.1.4.5.2.4ScalarethernetInterfaceIPv6StaticIPDefaultRouteread-onlymandatoryThe IPv6 static IP address default route for the ethernet interface. NOTE: If ethernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:…
1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3NodeethernetInterfaceIPv6AutoIPConfig
1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.2NodeethernetInterfaceDHCPv6Config
1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.2.1ScalarethernetInterfaceDHCPv6Enabledread-onlymandatoryThe DHCPv6 enabled or disabled state for the ethernet interface.
1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.2.2ScalarethernetInterfaceDHCPv6IPAddressread-onlymandatoryThe IPv6 address for the ethernet interface, assigned by DHCPv6 server. NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled is disabled or …
1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.2.4ScalarethernetInterfaceDHCPv6DomainNameread-onlymandatoryThe 64 byte Domain Name for the ethernet interface, assigned by the DHCPv6 server. NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled is d…
1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.2.5ScalarethernetInterfaceDHCPv6PrimaryDNSServerread-onlymandatoryThe primary DNS server, assigned by the DHCPv6 server. NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server …
1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.2.6ScalarethernetInterfaceDHCPv6SecondaryDNSServerread-onlymandatoryThe secondary DNS server, assigned by the DHCPv6 server. NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 serve…
1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.2.7ScalarethernetInterfaceDHCPv6TertiaryDNSServerread-onlymandatoryThe tertiary DNS server, assigned by the DHCPv6 server. NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server…
1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.2.8ScalarethernetInterfaceDHCPv6Serverread-onlymandatoryThe DHCPv6 server IPv6 address used to acquire the DHCP settings. NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled is disabled or if DHC…
1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.3NodeethernetInterfaceIPv6StatelessAutoConfig
1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.3.1ScalarethernetInterfaceIPv6StatelessAutoConfigEnabledread-onlymandatoryThe IPv6 stateless auto-configuration enabled or disabled state for the ethernet interface.
1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.3.2TableethernetInterfaceStatelessAutoConfigAddressesTablenot-accessiblemandatoryTable of stateless Auto-Config addresses entries
1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.3.2.1RowethernetInterfaceStatelessAutoConfigAddressesEntrynot-accessiblemandatoryStateless Auto-Config address entries
1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.3.2.1.1ColumnethernetInterfaceStatelessAutoConfigAddressesIndexread-onlymandatoryIndex for stateless Auto-Config addresses. NOTE: If ethernetInterfaceIPv6StatelessAutoConfigEnabled or ethernetInterfaceIPv6Enabled is currently disabled, this…
1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.3.2.1.2ColumnethernetInterfaceStatelessAutoConfigAddressesread-onlymandatoryThe stateless Auto-Configuration IPv6 address. NOTE: If ethernetInterfaceIPv6StatelessAutoConfigEnabled or ethernetInterfaceIPv6Enabled is currently disabled, …
1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.3.2.1.3ColumnethernetInterfaceStatelessAutoConfigAddressesPrefixLenread-onlymandatoryThe stateless Auto-Configration address prefix length. NOTE: If ethernetInterfaceIPv6StatelessAutoConfigEnabled or ethernetInterfaceIPv6Enabled is currently di…
1.3.6.1.4.1.19046.11.1.3.4.1.5NodevlansSM
1.3.6.1.4.1.19046.11.1.3.4.1.5.1NodevlansSMvlan1config
1.3.6.1.4.1.19046.11.1.3.4.1.5.1.1ScalarvlansSMvlan1Nameread-onlymandatoryThe name of VLAN1, 1-64 characters.
1.3.6.1.4.1.19046.11.1.3.4.1.5.1.2ScalarvlansSMvlan1vlanIdread-onlymandatoryThe VLAN ID for VLAN1.
1.3.6.1.4.1.19046.11.1.3.4.1.5.1.3ScalarvlansSMvlan1Stateread-onlymandatoryThe state of VLAN1
1.3.6.1.4.1.19046.11.1.3.4.1.5.1.4ScalarvlansSMvlan1RemoteControlread-onlymandatoryThe state of the Remote Control feature for VLAN1. Note that Remote Control can only be enabled on one VLAN.
1.3.6.1.4.1.19046.11.1.3.4.1.5.1.5ScalarvlansSMvlan1SSerialOverLanread-onlymandatoryThe state of the Serail Over LAN feature for VLAN1. Note that Serial Over LAN can only be enabled on one VLAN.
1.3.6.1.4.1.19046.11.1.3.4.1.5.2NodevlansSMvlan2config
1.3.6.1.4.1.19046.11.1.3.4.1.5.2.1ScalarvlansSMvlan2Nameread-onlymandatoryThe name of VLAN1, 1-64 characters.
1.3.6.1.4.1.19046.11.1.3.4.1.5.2.2ScalarvlansSMvlan2vlanIdread-onlymandatoryThe VLAN ID for VLAN2.
1.3.6.1.4.1.19046.11.1.3.4.1.5.2.3ScalarvlansSMvlan2Stateread-onlymandatoryThe state of VLAN2
1.3.6.1.4.1.19046.11.1.3.4.1.5.2.4ScalarvlansSMvlan2RemoteControlread-onlymandatoryThe state of the Remote Control feature for VLAN2. Note that Remote Control can only be enabled on one VLAN.
1.3.6.1.4.1.19046.11.1.3.4.1.5.2.5ScalarvlansSMvlan2SerialOverLanread-onlymandatoryThe state of the Serail Over LAN feature for VLAN2. Note that Serial Over LAN can only be enabled on one VLAN.
1.3.6.1.4.1.19046.11.1.3.4.1.5.2.6NodevlansSMvlan2ipv4Config
1.3.6.1.4.1.19046.11.1.3.4.1.5.2.6.1ScalarvlansSMvlan2IPv4Addressread-onlymandatoryContains the IPv4 address for the VLAN2 interface.
1.3.6.1.4.1.19046.11.1.3.4.1.5.2.6.2ScalarvlansSMvlan2IPv4Gatewayread-onlymandatoryContains the Gateway IPv4 address for the VLAN2 interface.
1.3.6.1.4.1.19046.11.1.3.4.1.5.2.6.3ScalarvlansSMvlan2IPv4SubnetMaskread-onlymandatoryContains the Subnet Mask for the IPv4 address for the VLAN2 interface.
1.3.6.1.4.1.19046.11.1.3.4.1.5.2.7NodevlansSMvlan2ipv6Config
1.3.6.1.4.1.19046.11.1.3.4.1.5.2.7.1ScalarvlansSMvlan2IPv6Addressread-onlymandatoryContains the IPv6 address for the VLAN2 interface.
1.3.6.1.4.1.19046.11.1.3.4.1.5.2.7.2ScalarvlansSMvlan2IPv6Gatewayread-onlymandatoryContains the Gateway IPv6 address for the VLAN2 interface.
1.3.6.1.4.1.19046.11.1.3.4.1.5.2.7.3ScalarvlansSMvlan2IPv6PrefixLengthread-onlymandatoryContains the Prefix Length for the IPv6 address for the VLAN2 interface.
1.3.6.1.4.1.19046.11.1.3.4.1.5.2.8NodevlansSMvlan2ipv4StatusRoutes
1.3.6.1.4.1.19046.11.1.3.4.1.5.2.8.1ScalarvlansSMvlan2IPv4StaticRouteIP1read-onlymandatoryContains the IPv4 address for the first IPv4 static route.
1.3.6.1.4.1.19046.11.1.3.4.1.5.2.8.2ScalarvlansSMvlan2IPv4StaticRouteSM1read-onlymandatoryContains the Subnet Mask for the first IPv4 static route.
1.3.6.1.4.1.19046.11.1.3.4.1.5.2.8.3ScalarvlansSMvlan2IPv4StaticRouteIP2read-onlymandatoryContains the IPv4 address for the second IPv4 static route.
1.3.6.1.4.1.19046.11.1.3.4.1.5.2.8.4ScalarvlansSMvlan2IPv4StaticRouteSM2read-onlymandatoryContains the Subnet Mask for the second IPv4 static route.
1.3.6.1.4.1.19046.11.1.3.4.1.5.2.8.5ScalarvlansSMvlan2IPv4StaticRouteIP3read-onlymandatoryContains the IPv4 address for the third IPv4 static route.
1.3.6.1.4.1.19046.11.1.3.4.1.5.2.8.6ScalarvlansSMvlan2IPv4StaticRouteSM3read-onlymandatoryContains the Subnet Mask for the third IPv4 static route.
1.3.6.1.4.1.19046.11.1.3.4.1.5.2.9NodevlansSMvlan2ipv6StatusRoutes
1.3.6.1.4.1.19046.11.1.3.4.1.5.2.9.1ScalarvlansSMvlan2IPv6StaticRouteIP1read-onlymandatoryContains the IPv6 address for the first IPv6 static route.
1.3.6.1.4.1.19046.11.1.3.4.1.5.2.9.2ScalarvlansSMvlan2IPv6StaticRoutePL1read-onlymandatoryContains the Prefix Length for the first IPv6 static route.
1.3.6.1.4.1.19046.11.1.3.4.1.5.2.9.3ScalarvlansSMvlan2IPv6StaticRouteIP2read-onlymandatoryContains the IPv6 address for the second IPv6 static route.
1.3.6.1.4.1.19046.11.1.3.4.1.5.2.9.4ScalarvlansSMvlan2IPv6StaticRoutePL2read-onlymandatoryContains the Prefix Length for the second IPv6 static route.
1.3.6.1.4.1.19046.11.1.3.4.1.5.2.9.5ScalarvlansSMvlan2IPv6StaticRouteIP3read-onlymandatoryContains the IPv6 address for the third IPv6 static route.
1.3.6.1.4.1.19046.11.1.3.4.1.5.2.9.6ScalarvlansSMvlan2IPv6StaticRoutePL3read-onlymandatoryContains the Prefix Length for the third IPv6 static route.
1.3.6.1.4.1.19046.11.1.3.4.1.5.3NodevlansSMvlanControl
1.3.6.1.4.1.19046.11.1.3.4.1.5.3.1ScalarvlansSMvlanConfigRevertTimoutread-onlymandatoryContains the VLAN Config Revert Timeout value.
1.3.6.1.4.1.19046.11.1.3.4.1.10ScalarddnsStatusread-onlymandatoryDynamic DNS provides the capability for a networked device to notify a domain name server to change, in real time, the active DNS configuration of its configur…
1.3.6.1.4.1.19046.11.1.3.4.1.11ScalarhostNameread-onlymandatoryContains the DNS host name for this system. This object provides the exact same function as ethernetInterfaceHostName
1.3.6.1.4.1.19046.11.1.3.4.1.12ScalarddnsDomainToUseread-onlymandatoryThe domain name to be used with Dynamic DNS.
1.3.6.1.4.1.19046.11.1.3.4.1.13ScalardomainNameread-onlymandatoryThe user assigned DNS domain name.
1.3.6.1.4.1.19046.11.1.3.4.1.14NodelanOverUSBInterface
1.3.6.1.4.1.19046.11.1.3.4.1.14.1ScalarxccUSBIPAddressread-onlymandatoryContains the IP address for the LAN over USB of XCC.
1.3.6.1.4.1.19046.11.1.3.4.1.14.2ScalarxccUSBSubnetMaskread-onlymandatoryContains the Subnet Mask for the LAN over USB of XCC.
1.3.6.1.4.1.19046.11.1.3.4.1.14.3ScalarosUSBIPAddressread-onlymandatoryContains the IP address for the LAN over USB of OS.
1.3.6.1.4.1.19046.11.1.3.4.2NodetcpProtocols
1.3.6.1.4.1.19046.11.1.3.4.2.1NodesnmpAgentConfig
1.3.6.1.4.1.19046.11.1.3.4.2.1.1ScalarsnmpSystemNameread-onlymandatoryA NULL terminated 48 byte string that contains the SNMP agent name.
1.3.6.1.4.1.19046.11.1.3.4.2.1.2ScalarsnmpSystemContactread-onlymandatoryA NULL terminated 48 byte string that contains the SNMP agent contact name.
1.3.6.1.4.1.19046.11.1.3.4.2.1.3ScalarsnmpSystemLocationread-onlymandatoryA NULL terminated 48 byte string that contains the SNMP agent location name.
1.3.6.1.4.1.19046.11.1.3.4.2.1.4ScalarsnmpSystemAgentTrapsDisableread-onlymandatoryDisable or enable SNMP V1 and V3 traps.
1.3.6.1.4.1.19046.11.1.3.4.2.1.5NodesnmpAgentCommunityConfig
1.3.6.1.4.1.19046.11.1.3.4.2.1.5.1ScalarsnmpCommunityEntryCommunityNameread-onlymandatorySNMP Community entry name.
1.3.6.1.4.1.19046.11.1.3.4.2.1.5.2ScalarsnmpCommunityEntryCommunityIpAddressread-onlymandatorySNMP Community IP address or host name.
1.3.6.1.4.1.19046.11.1.3.4.2.1.7Scalarsnmpv3SystemAgentEnableread-onlymandatoryDisable or enable the SNMPv3 agent.
1.3.6.1.4.1.19046.11.1.3.4.2.1.8NodesnmpAgentUserProfileConfig
1.3.6.1.4.1.19046.11.1.3.4.2.1.8.1TablesnmpUserProfileTablenot-accessiblemandatoryTable of SNMPv3 User Profile entries
1.3.6.1.4.1.19046.11.1.3.4.2.1.8.1.1RowsnmpUserProfileEntrynot-accessiblemandatorySNMP User Profile entries
1.3.6.1.4.1.19046.11.1.3.4.2.1.8.1.1.1ColumnsnmpUserProfileEntryIndexread-onlymandatoryIndex for SNMPv3 Agent User Profile entry.
1.3.6.1.4.1.19046.11.1.3.4.2.1.8.1.1.2ColumnsnmpUserProfileEntryAuthProtread-onlymandatorySNMPv3 User Profile entry - Authentication Protocol supported by the user.
1.3.6.1.4.1.19046.11.1.3.4.2.1.8.1.1.3ColumnsnmpUserProfileEntryPrivProtread-onlymandatorySNMPv3 User Profile entry - Privacy Protocol supported by the user.
1.3.6.1.4.1.19046.11.1.3.4.2.1.8.1.1.5ColumnsnmpUserProfileEntryViewTyperead-onlymandatorySNMPv3 User Profile entry - Access level (Get) of the user.
1.3.6.1.4.1.19046.11.1.3.4.2.1.8.1.1.6ColumnsnmpUserProfileEntryIpAddressread-onlymandatorySNMPv3 User Profile entry - IP address or host name.
1.3.6.1.4.1.19046.11.1.3.4.2.2NodednsConfig
1.3.6.1.4.1.19046.11.1.3.4.2.2.1ScalardnsEnabledread-onlymandatoryDisable or enable the DNS agent.
1.3.6.1.4.1.19046.11.1.3.4.2.2.2ScalardnsServerIPAddress1read-onlymandatoryContains the primary DNS server IP address.
1.3.6.1.4.1.19046.11.1.3.4.2.2.3ScalardnsServerIPAddress2read-onlymandatoryContains the secondary DNS server IP address.
1.3.6.1.4.1.19046.11.1.3.4.2.2.4ScalardnsServerIPAddress3read-onlymandatoryContains the tertiary DNS server IP address.
1.3.6.1.4.1.19046.11.1.3.4.2.2.12ScalardnsServerIPv6Address1read-onlymandatoryContains the primary IPv6 DNS server address.
1.3.6.1.4.1.19046.11.1.3.4.2.2.13ScalardnsServerIPv6Address2read-onlymandatoryContains the secondary IPv6 DNS server address.
1.3.6.1.4.1.19046.11.1.3.4.2.2.14ScalardnsServerIPv6Address3read-onlymandatoryContains the tertiary IPv6 DNS server address.
1.3.6.1.4.1.19046.11.1.3.4.2.2.20ScalardnsPriorityread-onlymandatoryTells the order host names are resolved. The options are to either first resolve with an IPv6 DNS server or to first resolve with an IPv6 DNS server.
1.3.6.1.4.1.19046.11.1.3.4.2.2.21ScalardnsLXCADiscoveryread-onlymandatoryDisable or enable LXCA discovery using DNS SRV records.
1.3.6.1.4.1.19046.11.1.3.4.2.3NodesmtpConfig
1.3.6.1.4.1.19046.11.1.3.4.2.3.1ScalarsmtpServerNameOrIPAddressread-onlymandatoryA NULL terminated 64 byte string that contains the SMTP server Host name or IP address(a.b.c.d).
1.3.6.1.4.1.19046.11.1.3.4.2.3.2ScalarsmtpServerPortread-onlymandatorySMTP server port number.
1.3.6.1.4.1.19046.11.1.3.4.2.3.3ScalarsmtpServerAuthenticationread-onlymandatoryEnable/disable SMTP-AUTH function.
1.3.6.1.4.1.19046.11.1.3.4.2.3.4ScalarsmtpServerAuthenticationUserread-onlymandatorySMTP authentication user name
1.3.6.1.4.1.19046.11.1.3.4.2.3.6ScalarsmtpServerAuthenticationMethodread-onlymandatorySMTP authentication method , support CRAM-MD5 and PLAIN only
1.3.6.1.4.1.19046.11.1.3.4.2.3.7ScalarsmtpServerReversePathread-onlymandatoryA NULL terminated 256 byte string that contains the SMTP Reverse Path. The user can substitute their own sender information in place of the XCC default sender …
1.3.6.1.4.1.19046.11.1.3.4.2.4NodetcpApplicationConfig
1.3.6.1.4.1.19046.11.1.3.4.2.4.2ScalarslpAddrTyperead-onlymandatoryGet SLP address type. Note that when slpAddrType is broadast then the multicast address in slpMulticastAddt will be ignored.
1.3.6.1.4.1.19046.11.1.3.4.2.4.3ScalarslpMulticastAddrread-onlymandatoryService Locator Protocol Multicast address
1.3.6.1.4.1.19046.11.1.3.4.2.4.5NodesshServerConfig
1.3.6.1.4.1.19046.11.1.3.4.2.4.5.1ScalarsshServerHostKeySizeread-onlymandatoryThe size of the public/private host key pair. NOTE: The XCC supports only the bits1048 value.
1.3.6.1.4.1.19046.11.1.3.4.2.4.5.2ScalarsshServerHostKeyFingerprintread-onlymandatoryThe RSA fingerprint of the public part of the host key pair. This value can be used with the SSH client to verify, on the initial connection, that the Secure S…
1.3.6.1.4.1.19046.11.1.3.4.2.4.5.5ScalarsshEnableread-onlymandatoryDisable/Enable SSH.
1.3.6.1.4.1.19046.11.1.3.4.2.4.6NodesslConfig
1.3.6.1.4.1.19046.11.1.3.4.2.4.6.1ScalarsslEnableHTTPSforWebread-onlymandatoryGet the status for web HTTPS service. To use SSL, a client web browser must be configured to use SSL3 and/or TLS. Older export-grade browsers with only SSL2 su…
1.3.6.1.4.1.19046.11.1.3.4.2.4.6.2ScalarsslEnableHTTPSforCIMXMLread-onlymandatoryGet the status for CIM over HTTPS service.
1.3.6.1.4.1.19046.11.1.3.4.2.4.6.3ScalarsslEnableSecureClientLDAPread-onlymandatoryGet the status of the Secure LDAP Client.
1.3.6.1.4.1.19046.11.1.3.4.2.4.6.4NodesslServerCertificate
1.3.6.1.4.1.19046.11.1.3.4.2.4.6.4.1ScalarsslServerCertificateStatusread-onlymandatoryGet the status of the installed HTTPS certificate. 1 = Private Key and Cert/CSR not available. 2 = Private Key and Self-signed cert installed. 3 = Private Key …
1.3.6.1.4.1.19046.11.1.3.4.2.4.6.4.2ScalarsslServerCertificateExpirationDateread-onlymandatoryExpiration date of the installed HTTPS certificate.
1.3.6.1.4.1.19046.11.1.3.4.2.4.6.5NodesslLDAPTrustedCertificate
1.3.6.1.4.1.19046.11.1.3.4.2.4.6.5.1ScalarsslLDAPTrustedCertificate1Statusread-onlymandatoryGet the status of the LDAP trusted certificate #1. 0 = certificate not installed 1 = certificate installed.
1.3.6.1.4.1.19046.11.1.3.4.2.4.6.5.2ScalarsslLDAPTrustedCertificate1ExpirationDateread-onlymandatoryExpiration date of the LDAP trusted certificate #1 if it is installed.
1.3.6.1.4.1.19046.11.1.3.4.2.4.6.5.3ScalarsslLDAPTrustedCertificate2Statusread-onlymandatoryGet the status of the LDAP trusted certificate #2. 0 = certificate not installed 1 = certificate installed.
1.3.6.1.4.1.19046.11.1.3.4.2.4.6.5.4ScalarsslLDAPTrustedCertificate2ExpirationDateread-onlymandatoryExpiration date of the LDAP trusted certificate #2 if it is installed..
1.3.6.1.4.1.19046.11.1.3.4.2.4.6.5.5ScalarsslLDAPTrustedCertificate3Statusread-onlymandatoryGet the status of the LDAP trusted certificate #3. 0 = certificate not installed 1 = certificate installed.
1.3.6.1.4.1.19046.11.1.3.4.2.4.6.5.6ScalarsslLDAPTrustedCertificate3ExpirationDateread-onlymandatoryExpiration date of the LDAP trusted certificate #3 if it is installed.
1.3.6.1.4.1.19046.11.1.3.4.2.4.6.5.7ScalarsslLDAPTrustedCertificate4Statusread-onlymandatoryGet the status of the LDAP trusted certificate #4. 0 = certificate not installed 1 = certificate installed.
1.3.6.1.4.1.19046.11.1.3.4.2.4.6.5.8ScalarsslLDAPTrustedCertificate4ExpirationDateread-onlymandatoryExpiration date of the LDAP trusted certificate #4 if it is installed.
1.3.6.1.4.1.19046.11.1.3.4.2.4.8NodecertDomainNames
1.3.6.1.4.1.19046.11.1.3.4.2.4.8.1TablecertDomainNameTablenot-accessiblemandatoryThis table contains certificate domain names and status.
1.3.6.1.4.1.19046.11.1.3.4.2.4.8.1.1RowcertDomainNameEntrynot-accessiblemandatoryEach row contains a certificate domain name and status.
1.3.6.1.4.1.19046.11.1.3.4.2.4.8.1.1.1ColumncertDomainNameIndexread-onlymandatoryThe index number of one certificate domain name entry.
1.3.6.1.4.1.19046.11.1.3.4.2.4.8.1.1.2ColumncertDomainNameread-onlymandatoryThe Certificate Domain Name of one certificate domain name entry.
1.3.6.1.4.1.19046.11.1.3.4.2.4.8.1.1.3ColumncertDomainNameStatusread-onlymandatoryThe status of the Certificate Domain Name entry.
1.3.6.1.4.1.19046.11.1.3.4.2.4.9NodeskrServers
1.3.6.1.4.1.19046.11.1.3.4.2.4.9.1TableskrServerTablenot-accessiblemandatoryThis table contains Storage Key Repository Server hostnames and ports.
1.3.6.1.4.1.19046.11.1.3.4.2.4.9.1.1RowskrServerEntrynot-accessiblemandatoryEach row contains a Storage Key Repository Server hostname and port.
1.3.6.1.4.1.19046.11.1.3.4.2.4.9.1.1.1ColumnskrServerIndexread-onlymandatoryThe index number of one Storage Key Repository Server entry.
1.3.6.1.4.1.19046.11.1.3.4.2.4.9.1.1.2ColumnskrServerHostnameread-onlymandatoryStorage Key Repository Server hostname or IP address.
1.3.6.1.4.1.19046.11.1.3.4.2.4.9.1.1.3ColumnskrServerPortread-onlymandatoryStorage Key Repository Server port number.
1.3.6.1.4.1.19046.11.1.3.4.2.4.9.3ScalarskrDeviceGroupread-onlymandatoryAn optional NULL terminated 16 character string that contains the Device Group that the server drives belong to.
1.3.6.1.4.1.19046.11.1.3.4.2.4.9.4NodeskrClientConfigCertficate
1.3.6.1.4.1.19046.11.1.3.4.2.4.9.4.3ScalarskrClientCertificateStatusread-onlymandatoryGet the status of the installed Web certificates. 1 = Private Key and Cert/CSR not available. 2 = Private Key and Self-signed cert installed. 3 = Private Key a…
1.3.6.1.4.1.19046.11.1.3.4.2.4.9.4.4ScalarskrClientCertificateExpirationDateread-onlymandatoryExpiration date of the SKR client certificate.
1.3.6.1.4.1.19046.11.1.3.4.2.4.9.12ScalarskrServerCertificateExpirationDateread-onlymandatoryExpiration date of the SKR Server certificate.
1.3.6.1.4.1.19046.11.1.3.4.2.5NodetcpPortAssignmentCfg
1.3.6.1.4.1.19046.11.1.3.4.2.5.2ScalarhttpPortAssignmentread-onlymandatoryHTTP port number. Default value is 80. Once changed, the url's have to include :port at the end.
1.3.6.1.4.1.19046.11.1.3.4.2.5.3ScalarhttpsPortAssignmentread-onlymandatorySSL port number. Default value is 443. Once changed, the url's have to include :port at the end.
1.3.6.1.4.1.19046.11.1.3.4.2.5.6ScalarsshLegacyCLIPortAssignmentread-onlymandatorySSH port number. Default value is 22.
1.3.6.1.4.1.19046.11.1.3.4.2.5.8ScalarsnmpAgentPortAssignmentread-onlymandatorySNMP Agent port number. Default value is 161.
1.3.6.1.4.1.19046.11.1.3.4.2.5.9ScalarsnmpTrapsPortAssignmentread-onlymandatorySNMP Traps port number. Default value is 162.
1.3.6.1.4.1.19046.11.1.3.4.2.5.10ScalarremvidPortAssignmentread-onlymandatoryRemote Console port number. Default value is 3900.
1.3.6.1.4.1.19046.11.1.3.4.2.5.12ScalarcimOverHttpsPortAssignmentread-onlymandatoryCIM over Https port number.
1.3.6.1.4.1.19046.11.1.3.4.2.6NodeldapClientCfg
1.3.6.1.4.1.19046.11.1.3.4.2.6.1ScalarldapServer1NameOrIPAddressread-onlymandatoryA NULL terminated 64 byte string that contains the LDAP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.19046.11.1.3.4.2.6.2ScalarldapServer1PortNumberread-onlymandatoryLDAP server port number.
1.3.6.1.4.1.19046.11.1.3.4.2.6.3ScalarldapServer2NameOrIPAddressread-onlymandatoryA NULL terminated 64 byte string that contains the LDAP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.19046.11.1.3.4.2.6.4ScalarldapServer2PortNumberread-onlymandatoryLDAP server port number.
1.3.6.1.4.1.19046.11.1.3.4.2.6.5ScalarldapServer3NameOrIPAddressread-onlymandatoryA NULL terminated 64 byte string that contains the LDAP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.19046.11.1.3.4.2.6.6ScalarldapServer3PortNumberread-onlymandatoryLDAP server port number.
1.3.6.1.4.1.19046.11.1.3.4.2.6.7ScalarldapServer4NameOrIPAddressread-onlymandatoryA NULL terminated 64 byte string that contains the LDAP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.19046.11.1.3.4.2.6.8ScalarldapServer4PortNumberread-onlymandatoryLDAP server port number.
1.3.6.1.4.1.19046.11.1.3.4.2.6.9ScalarldapRootDNread-onlymandatoryDistinguished Name for root entry of directory tree. An example might look like dn=foobar,dn=com.
1.3.6.1.4.1.19046.11.1.3.4.2.6.11ScalarldapGroupFilterread-onlymandatoryThis filter is used for group authentication. It specifies what group or groups that this MM belongs to. If left blank, group authentication is disabled. Other…
1.3.6.1.4.1.19046.11.1.3.4.2.6.12ScalarldapBindingMethodread-onlymandatoryOn initial binds to the LDAP server during user authentication, there are three options: Anonymous authentication: Bind attempt is made without a client DN or …
1.3.6.1.4.1.19046.11.1.3.4.2.6.13ScalarldapClientAuthenticationDNread-onlymandatoryThe initial bind to the LDAP server during user authentication can be performed with anonymous authentication, client based authentication, or UPN. The client …
1.3.6.1.4.1.19046.11.1.3.4.2.6.15ScalarldapRoleBasedSecurityEnabledread-onlymandatoryA value of true for RoleBasedSecurityEnabled indicates enhanced will be used by the service processor. A value of false for RoleBasedSecurityEnabled indicates …
1.3.6.1.4.1.19046.11.1.3.4.2.6.16ScalarldapServerTargetNameread-onlymandatoryWhen administrator chooses Enhanced Role Based Security authentication model, he can associate one XCC with one managed target object in Snap-in (one tool to c…
1.3.6.1.4.1.19046.11.1.3.4.2.6.17ScalarldapUIDsearchAttributeread-onlymandatoryWhen the binding method selected is Anonymous authentication or Client authentication, the initial bind to the LDAP server is followed by a search request aime…
1.3.6.1.4.1.19046.11.1.3.4.2.6.18ScalarldapGroupSearchAttributeread-onlymandatoryWhen the MM Group Filter name is configured, it is necessary to retrieve from the LDAP server the list of groups that a particular user belongs to. This is req…
1.3.6.1.4.1.19046.11.1.3.4.2.6.19ScalarldapLoginPermissionAttributeread-onlymandatoryWhen a user successfully authenticates via a LDAP server, it is necessary to retrieve the login permissions for this user. In order to retrieve these permissio…
1.3.6.1.4.1.19046.11.1.3.4.2.6.20ScalarldapUseDNSOrPreConfiguredServersread-onlymandatoryThe MM contains a Version 2.0 LDAP Client that may be configured to provide user authentication through one or more LDAP servers. The LDAP server(s) to be used…
1.3.6.1.4.1.19046.11.1.3.4.2.6.21ScalarldapDomainSourceread-onlymandatoryThe DNS SRV request sent to the DNS server must specify a domain name. The LDAP client will determine where to get this domain name based on one of the followi…
1.3.6.1.4.1.19046.11.1.3.4.2.6.22ScalarldapForestNameread-onlymandatoryIn order to discover Global Catalogs (GC), the forest name must be configured in the ForestName property. The Global Catalogs are required for users who belong…
1.3.6.1.4.1.19046.11.1.3.4.2.6.23ScalarldapAuthCfgread-onlymandatoryIf ldapAuthCfg is set to 0, LDAP server is used to authenticate and authorize users. If it is set to 1, LDAP server is only used to authenticate users. Note:LD…
1.3.6.1.4.1.19046.11.1.3.4.2.6.24ScalarldapSearchDomainread-onlymandatoryThis parameter may be used as the domain name in the DNS SRV request, depending on how the Domain Source parameter is configured.
1.3.6.1.4.1.19046.11.1.3.4.2.6.25ScalarldapServiceNameread-onlymandatoryThe DNS SRV request sent to the DNS server must also specify a service name. The configured value will be used for this purpose. If left blank, the default val…
1.3.6.1.4.1.19046.11.1.3.4.2.8NodentpConfig
1.3.6.1.4.1.19046.11.1.3.4.2.8.1ScalarntpEnableread-onlymandatoryDisable/Enable the NTP client. The client will update the XCC system clock at the frequency specified.
1.3.6.1.4.1.19046.11.1.3.4.2.8.2ScalarntpIpAddressHostname1read-onlymandatoryFirst NTP server's IP address or hostname if DNS is enabled and configured.
1.3.6.1.4.1.19046.11.1.3.4.2.8.3ScalarntpUpdateFrequencyread-onlymandatoryThe frequency in minutes that the NTP service runs. The value range is 3 to 1440.
1.3.6.1.4.1.19046.11.1.3.4.2.8.4ScalarntpIpAddressHostname2read-onlymandatorySecond NTP server's IP address or hostname if DNS is enabled and configured.
1.3.6.1.4.1.19046.11.1.3.4.2.8.6ScalarntpIpAddressHostname3read-onlymandatoryThird NTP server's IP address or hostname if DNS is enabled and configured.
1.3.6.1.4.1.19046.11.1.3.4.2.8.7ScalarntpIpAddressHostname4read-onlymandatoryFourth NTP server's IP address or hostname if DNS is enabled and configured.
1.3.6.1.4.1.19046.11.1.3.4.2.10NodeipmiConfig
1.3.6.1.4.1.19046.11.1.3.4.2.10.1ScalaripmiStatusread-onlymandatoryGet the status of IPMI service
1.3.6.1.4.1.19046.11.1.3.4.2.11NodecimxmlConfig
1.3.6.1.4.1.19046.11.1.3.4.2.11.1ScalarcimxmlStatusread-onlymandatoryGet the status of CIM service.
1.3.6.1.4.1.19046.11.1.3.4.2.12NoderestConfig
1.3.6.1.4.1.19046.11.1.3.4.2.12.1ScalarrestStatusread-onlymandatoryGet the status of the REST over HTTPS.
1.3.6.1.4.1.19046.11.1.3.7ScalarxccVersionCheckread-onlymandatoryGet the XCC version type.
1.3.6.1.4.1.19046.11.1.4NodegeneralSystemSettings
1.3.6.1.4.1.19046.11.1.4.1NodeserverTimers
1.3.6.1.4.1.19046.11.1.4.1.1ScalaroSHangread-onlymandatoryNumber, in 1 second intervals, the XCC will check to insure the OS is operating properly. If the operating system fails to respond within 6 seconds to one of t…
1.3.6.1.4.1.19046.11.1.4.1.2ScalaroSLoaderread-onlymandatoryNumber in 30 second intervals the remote XCC will wait between completion of POST and the end of loading the OS. If this interval is exceeded, the XCC will gen…
1.3.6.1.4.1.19046.11.1.4.2ScalarnetworkPXEbootread-onlymandatoryModify the system's boot sequence for the next system restart in order to attempt a PXE/DHCP network boot. The system's boot sequence(set via the BIOS settings…
1.3.6.1.4.1.19046.11.1.5NodesystemPower
1.3.6.1.4.1.19046.11.1.5.1NodepowerStatistics
1.3.6.1.4.1.19046.11.1.5.1.1ScalarcurrentSysPowerStatusread-onlymandatoryIndicates if the system is currently powered on, off, or in sleep state.
1.3.6.1.4.1.19046.11.1.5.1.2ScalarpowerOnHoursread-onlymandatoryNumber of hours the system has been powered on.
1.3.6.1.4.1.19046.11.1.5.1.3ScalarrestartCountread-onlymandatoryNumber of times the system has been restarted.
1.3.6.1.4.1.19046.11.1.5.1.4ScalarsystemStateread-onlymandatoryShows the current operational state of the system.
1.3.6.1.4.1.19046.11.1.5.2NodepowerSysConfig
1.3.6.1.4.1.19046.11.1.5.2.1ScalarpowerSysOffDelayread-onlymandatoryThe number of 1 second interval the XCC will wait before powering off the system.
1.3.6.1.4.1.19046.11.1.5.2.2ScalarpowerSysOnClockSettingread-onlymandatoryThe clock setting used to determine when the XCC will power on the system. For example the value '03/04/2001,06:00' means that the system will power on March 4…
1.3.6.1.4.1.19046.11.1.5.5NodepowerCyclingSchedule
1.3.6.1.4.1.19046.11.1.5.5.1ScalarschedulePowerOffWithOsShutdownread-onlymandatoryPower Off the system after performing a OS shutdown at specified time and day of the week. Example: Monday,09:00, To reset, the value as Never,00:00.
1.3.6.1.4.1.19046.11.1.5.5.2ScalarschedulePowerOnSystemread-onlymandatoryPower On the system at specified time and day of the week. Example: Monday,09:00. To reset, the value as Never,00:00.
1.3.6.1.4.1.19046.11.1.8NodeserviceAdvisor
1.3.6.1.4.1.19046.11.1.8.1NodeautoCallHomeSetup
1.3.6.1.4.1.19046.11.1.8.1.1ScalaracceptLicenseAgreementread-onlymandatoryAccept Terms and Conditions of Service Advisor. The user will have to accept the terms and conditions before Service Advisor can send diagnostic data to suppor…
1.3.6.1.4.1.19046.11.1.8.1.2ScalarserviceAdvisorEnableread-onlymandatoryDisable/Enable Call Home Support. The User Agreement must be accepted and the contact information must be set before the Call Home Support function of Service …
1.3.6.1.4.1.19046.11.1.8.2NodeserviceSupportCenter
1.3.6.1.4.1.19046.11.1.8.2.1ScalarlenovoSupportCenterread-onlymandatoryThe country code for the Support Center. 2 character ISO country code.
1.3.6.1.4.1.19046.11.1.8.3NodecontactInformation
1.3.6.1.4.1.19046.11.1.8.3.1ScalarcompanyNameread-onlymandatoryThe organization/company name of the contact person. 1-30 characters.
1.3.6.1.4.1.19046.11.1.8.3.2ScalarcontactNameread-onlymandatoryThe name of the contact person.1-30 characters.
1.3.6.1.4.1.19046.11.1.8.3.3ScalarphoneNumberread-onlymandatoryThe phone of the contact person. 5-30 characters.
1.3.6.1.4.1.19046.11.1.8.3.4ScalaremailAddressread-onlymandatoryThe email of the contact person. It must contain '@' and dot '.' in form userid@hostname (30 characters maximum). The userid can be alphanumeric characters, '.…
1.3.6.1.4.1.19046.11.1.8.3.5Scalaraddressread-onlymandatoryThe address of the machine location. The information in this field should be of sufficient detail to allow someone to quickly find the chassis when necessary. …
1.3.6.1.4.1.19046.11.1.8.3.6Scalarcityread-onlymandatoryThe city of the machine location. 1-30 characters.
1.3.6.1.4.1.19046.11.1.8.3.7Scalarstateread-onlymandatoryThe state of the machine location. 2-3 characters.
1.3.6.1.4.1.19046.11.1.8.3.8ScalarpostalCoderead-onlymandatoryThe postal code of the location for this system. 1-9 characters, only alphanumeric characters are valid.
1.3.6.1.4.1.19046.11.1.8.3.9ScalarphoneExtensionread-onlymandatoryThe phone extension of the contact person. 30 characters maximum.
1.3.6.1.4.1.19046.11.1.8.3.10ScalaraltContactNameread-onlymandatoryThe name of the alternate contact person. 1-30 characters.
1.3.6.1.4.1.19046.11.1.8.3.11ScalaraltPhoneNumberread-onlymandatoryThe phone of the alternate contact person. 5-30 characters.
1.3.6.1.4.1.19046.11.1.8.3.12ScalaraltPhoneExtensionread-onlymandatoryThe phone extension of the alternate contact person. 30 characters maximum.
1.3.6.1.4.1.19046.11.1.8.3.13ScalaraltEmailAddressread-onlymandatoryThe email of the alternate contact person. It must contain '@' and dot '.' in form userid@hostname (30 characters maximum). The userid can be alphanumeric char…
1.3.6.1.4.1.19046.11.1.8.3.14ScalarmachineLocationPhoneNumberread-onlymandatoryThe phone of the physical location where the compuer system resides. 5-30 characters.
1.3.6.1.4.1.19046.11.1.8.4NodehttpProxyConfig
1.3.6.1.4.1.19046.11.1.8.4.1ScalarhttpProxyEnableread-onlymandatoryDisable/Enable of the HTTP Proxy. HTTP Proxy is used by the XCC when it is not connected to the internet directly.
1.3.6.1.4.1.19046.11.1.8.4.2ScalarhttpProxyLocationread-onlymandatoryFully qualified host name or IP address of the HTTP Proxy. Maximum of 63 characters.
1.3.6.1.4.1.19046.11.1.8.4.3ScalarhttpProxyPortread-onlymandatoryThe port number of the HTTP Proxy. An integer value from 1 to 65535.
1.3.6.1.4.1.19046.11.1.8.4.4ScalarhttpProxyUserNameread-onlymandatoryUser Name of the HTTP Proxy. A maximum of 30 characters string without spaces.
1.3.6.1.4.1.19046.11.1.8.4.5ScalarhttpProxyPasswordread-onlymandatoryPassword of the HTTP Proxy. A maximum of 15 characters string without spaces.
1.3.6.1.4.1.19046.11.1.8.5NodeactivityLogs
1.3.6.1.4.1.19046.11.1.8.5.1TableactivityLogTablenot-accessiblemandatoryTable of Service Advisor Activity Log entries information. This table displays events that were generated by the system or user that are called home. The entri…
1.3.6.1.4.1.19046.11.1.8.5.1.1RowactivityLogEntrynot-accessiblemandatoryActivity Log table entry. Each entry has the result of the call-home attempt, the service number assigned for the issue by the Support Center, the event ID, ev…
1.3.6.1.4.1.19046.11.1.8.5.1.1.1ColumnactivityLogIndexread-onlymandatoryThe Activity Log index number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.19046.11.1.8.5.1.1.2ColumnactivityLogStringread-onlymandatoryA string of data detailing one Activity Log entry. The text message is from the original entry in the event log. For consistent results, view as a table and no…
1.3.6.1.4.1.19046.11.1.8.5.1.1.3ColumnactivityLogAcknowledgeread-onlymandatoryThe acknowledgement of one Activity Log entry as corrected. This field allows the users to set a reminder next to certain events to indicate their awareness of…
1.3.6.1.4.1.19046.11.1.8.5.1.1.4ColumnactivityLogAttributeread-onlymandatoryA string of data detailing one Activity Log entry's attribute. It contains states of both calling the Support Center and FTP/TFTP Server. A PENDING indicates t…
1.3.6.1.4.1.19046.11.1.8.6NodeautoFTPSetup
1.3.6.1.4.1.19046.11.1.8.6.1ScalarautoFTPCallModeread-onlymandatoryThis field specifies the automated problem reporting mode. Automated problem reporting mode allows the XCC to automatically put service data to a specified ser…
1.3.6.1.4.1.19046.11.1.8.6.2ScalarautoFTPCallAddrread-onlymandatoryThis field specifies the remote server address of FTP and TFTP. It should be fully qualified hostname or IP address.
1.3.6.1.4.1.19046.11.1.8.6.3ScalarautoFTPCallPortread-onlymandatoryThis field specifies the port on remote FTP/TFTP server for data transmission.
1.3.6.1.4.1.19046.11.1.8.6.4ScalarautoFTPCallUserIDread-onlymandatoryThis field specifies the user account to login remote FTP server.
1.3.6.1.4.1.19046.11.1.8.7NodecallHomeExclusionEvents
1.3.6.1.4.1.19046.11.1.8.7.1TablereadCallHomeExclusionEventTablenot-accessiblemandatoryTable of Call Home Exclusion Event entries information.
1.3.6.1.4.1.19046.11.1.8.7.1.1RowreadCallHomeExclusionEventEntrynot-accessiblemandatoryCall Home Exclusion Event table entry
1.3.6.1.4.1.19046.11.1.8.7.1.1.1ColumnreadCallHomeExclusionEventIndexread-onlymandatoryThe index number of one Call Home Exclusion Event. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.19046.11.1.8.7.1.1.2ColumnreadCallHomeExclusionEventIDread-onlymandatoryThe Event ID of one Call Home Exclusion Event entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.19046.11.1.158NodesupportProcessor