LIEBERT-SITENET-INTEGRATOR-MIB
192 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1 | NodeenvSummaryAlarmTrap | An envSummaryAlarmTrap is generated each time a digital input State variable changes to true(1) or whenever a temperature or humidity goes above the HighLimit … | ||
| 1.3.6.1.4.1.476 | Nodeemerson | |||
| 1.3.6.1.4.1.476.1 | NodeliebertCorp | |||
| 1.3.6.1.4.1.476.1.1 | NodeliebertUps | |||
| 1.3.6.1.4.1.476.1.2 | NodeliebertEnvironment | |||
| 1.3.6.1.4.1.476.1.2.1 | NodeleExtensions | |||
| 1.3.6.1.4.1.476.1.2.1.1 | NodeleSiteNet01 | |||
| 1.3.6.1.4.1.476.1.2.1.1.1 | NodeenvMIB | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.1 | NodeenvIdent | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.1.1 | ScalarenvIdentManufacturer | read-only | mandatory | The Environmental Control Unit manufacturer. |
| 1.3.6.1.4.1.476.1.2.1.1.1.1.2 | ScalarenvIdentModel | read-write | mandatory | The Environmental Control Unit Model designation. |
| 1.3.6.1.4.1.476.1.2.1.1.1.1.3 | ScalarenvIdentSoftwareVersion | read-only | mandatory | The Environmental SNMP Agent software version. |
| 1.3.6.1.4.1.476.1.2.1.1.1.1.4 | ScalarenvIdentSpecific | read-only | mandatory | A reference to MIB definitions specific to the particular Environmental Unit being managed. This object is used to locate the product-specific MIB for this dev… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2 | NodeenvDigitalInputs | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.2.1 | NodeenvDigInput1 | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.2.1.1 | ScalarenvDigInput1State | read-only | mandatory | The state of Digital Input Number 1. When the envDigInput1Polarity is set to notDefined(3) this variable returns notInstalled(3). When the envDigInput1Polarity… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.1.2 | ScalarenvDigInput1Label | read-write | mandatory | A user-defined text string associated with Digital Input Number 1. The text string is stored in non-volatile memory. |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.1.3 | ScalarenvDigInput1Polarity | read-write | mandatory | The Polarity to be associated with the State variable for Digital Input Number 1. It controls the value returned by the State variable. When Polarity is set to… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.1.4 | ScalarenvDigInput1TrapEnabled | read-write | mandatory | A TRAP may be associated with the State variable for Digital Input Number 1. When envDigInput1TrapEnabled is set to true(1), a TRAP message will be generated w… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.2 | NodeenvDigInput2 | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.2.2.1 | ScalarenvDigInput2State | read-only | mandatory | The state of Digital Input Number 2. When the envDigInput2Polarity is set to notDefined(3) this variable returns notInstalled(3). When the envDigInput2Polarity… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.2.2 | ScalarenvDigInput2Label | read-write | mandatory | A user-defined text string associated with Digital Input Number 2. The text string is stored in non-volatile memory. |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.2.3 | ScalarenvDigInput2Polarity | read-write | mandatory | The Polarity to be associated with the State variable for Digital Input Number 2. It controls the value returned by the State variable. When Polarity is set to… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.2.4 | ScalarenvDigInput2TrapEnabled | read-write | mandatory | A TRAP may be associated with the State variable for Digital Input Number 2. When envDigInput2TrapEnabled is set to true(1), a TRAP message will be generated w… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.3 | NodeenvDigInput3 | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.2.3.1 | ScalarenvDigInput3State | read-only | mandatory | The state of Digital Input Number 3. When the envDigInput3Polarity is set to notDefined(3) this variable returns notInstalled(3). When the envDigInput3Polarity… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.3.2 | ScalarenvDigInput3Label | read-write | mandatory | A user-defined text string associated with Digital Input Number 3. The text string is stored in non-volatile memory. |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.3.3 | ScalarenvDigInput3Polarity | read-write | mandatory | The Polarity to be associated with the State variable for Digital Input Number 3. It controls the value returned by the State variable. When Polarity is set to… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.3.4 | ScalarenvDigInput3TrapEnabled | read-write | mandatory | A TRAP may be associated with the State variable for Digital Input Number 3. When envDigInput3TrapEnabled is set to true(1), a TRAP message will be generated w… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.4 | NodeenvDigInput4 | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.2.4.1 | ScalarenvDigInput4State | read-only | mandatory | The state of Digital Input Number 4. When the envDigInput4Polarity is set to notDefined(3) this variable returns notInstalled(3). When the envDigInput4Polarity… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.4.2 | ScalarenvDigInput4Label | read-write | mandatory | A user-defined text string associated with Digital Input Number 4. The text string is stored in non-volatile memory. |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.4.3 | ScalarenvDigInput4Polarity | read-write | mandatory | The Polarity to be associated with the State variable for Digital Input Number 4. It controls the value returned by the State variable. When Polarity is set to… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.4.4 | ScalarenvDigInput4TrapEnabled | read-write | mandatory | A TRAP may be associated with the State variable for Digital Input Number 4. When envDigInput4TrapEnabled is set to true(1), a TRAP message will be generated w… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.5 | NodeenvDigInput5 | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.2.5.1 | ScalarenvDigInput5State | read-only | mandatory | The state of Digital Input Number 5. When the envDigInput5Polarity is set to notDefined(3) this variable returns notInstalled(3). When the envDigInput5Polarity… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.5.2 | ScalarenvDigInput5Label | read-write | mandatory | A user-defined text string associated with Digital Input Number 5. The text string is stored in non-volatile memory. |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.5.3 | ScalarenvDigInput5Polarity | read-write | mandatory | The Polarity to be associated with the State variable for Digital Input Number 5. It controls the value returned by the State variable. When Polarity is set to… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.5.4 | ScalarenvDigInput5TrapEnabled | read-write | mandatory | A TRAP may be associated with the State variable for Digital Input Number 5. When envDigInput5TrapEnabled is set to true(1), a TRAP message will be generated w… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.6 | NodeenvDigInput6 | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.2.6.1 | ScalarenvDigInput6State | read-only | mandatory | The state of Digital Input Number 6. When the envDigInput6Polarity is set to notDefined(3) this variable returns notInstalled(3). When the envDigInput6Polarity… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.6.2 | ScalarenvDigInput6Label | read-write | mandatory | A user-defined text string associated with Digital Input Number 6. The text string is stored in non-volatile memory. |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.6.3 | ScalarenvDigInput6Polarity | read-write | mandatory | The Polarity to be associated with the State variable for Digital Input Number 6. It controls the value returned by the State variable. When Polarity is set to… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.6.4 | ScalarenvDigInput6TrapEnabled | read-write | mandatory | A TRAP may be associated with the State variable for Digital Input Number 6. When envDigInput6TrapEnabled is set to true(1), a TRAP message will be generated w… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.7 | NodeenvDigInput7 | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.2.7.1 | ScalarenvDigInput7State | read-only | mandatory | The state of Digital Input Number 7. When the envDigInput7Polarity is set to notDefined(3) this variable returns notInstalled(3). When the envDigInput7Polarity… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.7.2 | ScalarenvDigInput7Label | read-write | mandatory | A user-defined text string associated with Digital Input Number 7. The text string is stored in non-volatile memory. |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.7.3 | ScalarenvDigInput7Polarity | read-write | mandatory | The Polarity to be associated with the State variable for Digital Input Number 7. It controls the value returned by the State variable. When Polarity is set to… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.7.4 | ScalarenvDigInput7TrapEnabled | read-write | mandatory | A TRAP may be associated with the State variable for Digital Input Number 7. When envDigInput7TrapEnabled is set to true(1), a TRAP message will be generated w… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.8 | NodeenvDigInput8 | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.2.8.1 | ScalarenvDigInput8State | read-only | mandatory | The state of Digital Input Number 8. When the envDigInput8Polarity is set to notDefined(3) this variable returns notInstalled(3). When the envDigInput8Polarity… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.8.2 | ScalarenvDigInput8Label | read-write | mandatory | A user-defined text string associated with Digital Input Number 8. The text string is stored in non-volatile memory. |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.8.3 | ScalarenvDigInput8Polarity | read-write | mandatory | The Polarity to be associated with the State variable for Digital Input Number 8. It controls the value returned by the State variable. When Polarity is set to… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.8.4 | ScalarenvDigInput8TrapEnabled | read-write | mandatory | A TRAP may be associated with the State variable for Digital Input Number 8. When envDigInput8TrapEnabled is set to true(1), a TRAP message will be generated w… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.9 | NodeenvDigInput9 | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.2.9.1 | ScalarenvDigInput9State | read-only | mandatory | The state of Digital Input Number 9. When the envDigInput9Polarity is set to notDefined(3) this variable returns notInstalled(3). When the envDigInput9Polarity… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.9.2 | ScalarenvDigInput9Label | read-write | mandatory | A user-defined text string associated with Digital Input Number 9. The text string is stored in non-volatile memory. |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.9.3 | ScalarenvDigInput9Polarity | read-write | mandatory | The Polarity to be associated with the State variable for Digital Input Number 9. It controls the value returned by the State variable. When Polarity is set to… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.9.4 | ScalarenvDigInput9TrapEnabled | read-write | mandatory | A TRAP may be associated with the State variable for Digital Input Number 9. When envDigInput9TrapEnabled is set to true(1), a TRAP message will be generated w… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.10 | NodeenvDigInput10 | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.2.10.1 | ScalarenvDigInput10State | read-only | mandatory | The state of Digital Input Number 10. When the envDigInput10Polarity is set to notDefined(3) this variable returns notInstalled(3). When the envDigInput10Polar… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.10.2 | ScalarenvDigInput10Label | read-write | mandatory | A user-defined text string associated with Digital Input Number 10. The text string is stored in non-volatile memory. |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.10.3 | ScalarenvDigInput10Polarity | read-write | mandatory | The Polarity to be associated with the State variable for Digital Input Number 10. It controls the value returned by the State variable. When Polarity is set t… |
| 1.3.6.1.4.1.476.1.2.1.1.1.2.10.4 | ScalarenvDigInput10TrapEnabled | read-write | mandatory | A TRAP may be associated with the State variable for Digital Input Number 10. When envDigInput10TrapEnabled is set to true(1), a TRAP message will be generated… |
| 1.3.6.1.4.1.476.1.2.1.1.1.3 | NodeenvRelays | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.3.1 | NodeenvRelay1 | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.3.1.1 | ScalarenvRelay1State | read-write | mandatory | The state of Output Relay Number 1. When State is set to on(1) Output Relay Number 1 is activated and the normally open contacts are closed. When State is set … |
| 1.3.6.1.4.1.476.1.2.1.1.1.3.1.2 | ScalarenvRelay1Label | read-write | mandatory | A user-defined text string associated with Output Relay Number 1. The text string is stored in non-volatile memory. |
| 1.3.6.1.4.1.476.1.2.1.1.1.3.1.3 | ScalarenvRelay1Control | read-write | mandatory | If Control value is 0 then this output may be directly controlled by the SNMP Manager. When Control contains any of the following values, or a value resulting … |
| 1.3.6.1.4.1.476.1.2.1.1.1.3.2 | NodeenvRelay2 | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.3.2.1 | ScalarenvRelay2State | read-write | mandatory | The state of Output Relay Number 2. When State is set to on(1) Output Relay Number 2 is activated and the normally open contacts are closed. When State is set … |
| 1.3.6.1.4.1.476.1.2.1.1.1.3.2.2 | ScalarenvRelay2Label | read-write | mandatory | A user-defined text string associated with Output Relay Number 2. The text string is stored in non-volatile memory. |
| 1.3.6.1.4.1.476.1.2.1.1.1.3.2.3 | ScalarenvRelay2Control | read-write | mandatory | If Control value is 0 then this output may be directly controlled by the SNMP Manager. When Control contains any of the following values, or a value resulting … |
| 1.3.6.1.4.1.476.1.2.1.1.1.4 | NodeenvOutputs | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.4.1 | NodeenvAudible | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.4.1.1 | ScalarenvAudibleState | read-write | mandatory | The state of the Audible Output. When State is set to on(1) the Audible will be sounded. When State is set to off(2) the Audible is muted. |
| 1.3.6.1.4.1.476.1.2.1.1.1.4.1.2 | ScalarenvAudibleControl | read-write | mandatory | If Control value is 0 then this output may be directly controlled by the SNMP Manager. When Control contains any of the following values, or a value resulting … |
| 1.3.6.1.4.1.476.1.2.1.1.1.4.2 | NodeenvLED1 | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.4.2.1 | ScalarenvLED1State | read-write | mandatory | The state of Output LED Number 1. When State is set to on(1) LED Number 1 will be lighted. When State is set to off(2) LED Number 1 will not be lighted. |
| 1.3.6.1.4.1.476.1.2.1.1.1.4.2.2 | ScalarenvLED1Label | read-write | mandatory | A user-defined text string associated with Output LED Number 1. The text string is stored in non-volatile memory. |
| 1.3.6.1.4.1.476.1.2.1.1.1.4.2.3 | ScalarenvLED1Control | read-write | mandatory | If Control value is 0 then this output may be directly controlled by the SNMP Manager. When Control contains any of the following values, or a value resulting … |
| 1.3.6.1.4.1.476.1.2.1.1.1.4.3 | NodeenvLED2 | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.4.3.1 | ScalarenvLED2State | read-write | mandatory | The state of Output LED Number 2. When State is set to on(1) LED Number 2 will be lighted. When State is set to off(2) LED Number 2 will not be lighted. |
| 1.3.6.1.4.1.476.1.2.1.1.1.4.3.2 | ScalarenvLED2Label | read-write | mandatory | A user-defined text string associated with Output LED Number 2. The text string is stored in non-volatile memory. |
| 1.3.6.1.4.1.476.1.2.1.1.1.4.3.3 | ScalarenvLED2Control | read-write | mandatory | If Control value is 0 then this output may be directly controlled by the SNMP Manager. When Control contains any of the following values, or a value resulting … |
| 1.3.6.1.4.1.476.1.2.1.1.1.4.4 | NodeenvLED3 | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.4.4.1 | ScalarenvLED3State | read-write | mandatory | The state of Output LED Number 3. When State is set to on(1) LED Number 3 will be lighted. When State is set to off(2) LED Number 3 will not be lighted. |
| 1.3.6.1.4.1.476.1.2.1.1.1.4.4.2 | ScalarenvLED3Label | read-write | mandatory | A user-defined text string associated with Output LED Number 3. The text string is stored in non-volatile memory. |
| 1.3.6.1.4.1.476.1.2.1.1.1.4.4.3 | ScalarenvLED3Control | read-write | mandatory | If Control value is 0 then this output may be directly controlled by the SNMP Manager. When Control contains any of the following values, or a value resulting … |
| 1.3.6.1.4.1.476.1.2.1.1.1.5 | NodeenvReceptacles | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.5.1 | NodeenvReceptacle1 | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.5.1.1 | ScalarenvReceptacle1State | read-write | mandatory | The state of the Receptacle Number 1. When State is set to on(1) power will be live on Receptacle Number 1. When State is set to off(2) no power is available f… |
| 1.3.6.1.4.1.476.1.2.1.1.1.5.1.2 | ScalarenvReceptacle1Label | read-write | mandatory | A user-defined text string associated with Receptacle Number 1. The text string is stored in non-volatile memory. |
| 1.3.6.1.4.1.476.1.2.1.1.1.5.2 | NodeenvReceptacle2 | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.5.2.1 | ScalarenvReceptacle2State | read-write | mandatory | The state of the Receptacle Number 2. When State is set to on(1) power will be live on Receptacle Number 2. When State is set to off(2) no power is available f… |
| 1.3.6.1.4.1.476.1.2.1.1.1.5.2.2 | ScalarenvReceptacle2Label | read-write | mandatory | A user-defined text string associated with Receptacle Number 2. The text string is stored in non-volatile memory. |
| 1.3.6.1.4.1.476.1.2.1.1.1.5.3 | NodeenvReceptacle3 | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.5.3.1 | ScalarenvReceptacle3State | read-write | mandatory | The state of the Receptacle Number 3. When State is set to on(1) power will be live on Receptacle Number 3. When State is set to off(2) no power is available f… |
| 1.3.6.1.4.1.476.1.2.1.1.1.5.3.2 | ScalarenvReceptacle3Label | read-write | mandatory | A user-defined text string associated with Receptacle Number 3. The text string is stored in non-volatile memory. |
| 1.3.6.1.4.1.476.1.2.1.1.1.5.4 | NodeenvReceptacle4 | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.5.4.1 | ScalarenvReceptacle4State | read-write | mandatory | The state of the Receptacle Number 4. When State is set to on(1) power will be live on Receptacle Number 4. When State is set to off(2) no power is available f… |
| 1.3.6.1.4.1.476.1.2.1.1.1.5.4.2 | ScalarenvReceptacle4Label | read-write | mandatory | A user-defined text string associated with Receptacle Number 4. The text string is stored in non-volatile memory. |
| 1.3.6.1.4.1.476.1.2.1.1.1.6 | NodeenvAlarms | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.6.1 | ScalarenvSummaryAlarm | read-only | mandatory | The envSummaryAlarm varible will be 0 when no Digital Inputs are true and no other alarm conditions exist. When alarms are active or Digital Inputs are true th… |
| 1.3.6.1.4.1.476.1.2.1.1.1.7 | NodeenvTemperatureSensors | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.7.1 | NodeenvTemperature1 | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.7.1.1 | ScalarenvTemperature1State | read-write | mandatory | The state of use of Temperature Input Number 1. When a sensor is connected to Temperature Input 1 set State to installed(2) to indicate that the value of envTe… |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.1.2 | ScalarenvTemperature1F | read-only | mandatory | The temperature for sensor 1 in degrees Fahrenheit. |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.1.3 | ScalarenvTemperature1C | read-only | mandatory | The temperature for sensor 1 in degrees Centigrade. |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.1.4 | ScalarenvTemperature1Label | read-write | mandatory | A user-defined text string associated with Temperature Input Number 1. The text string is stored in non-volatile memory. |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.1.5 | ScalarenvTemperature1OffsetF | read-write | mandatory | A temperature correction Offset associated with the envTemperature1F variable. The value of OffsetF is added to the value from Temperature Sensor Number 1 to o… |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.1.6 | ScalarenvTemperature1OffsetC | read-write | mandatory | A temperature correction Offset associated with the envTemperature1C variable. The value of OffsetC is added to the value from Temperature Sensor Number 1 to o… |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.1.7 | ScalarenvTemp1HighLimitF | read-write | mandatory | When envTemperature1F reaches or exceeds this value a trap will be generated signifying a high temperature condition at temperature sensor 1. The HighLimitF va… |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.1.8 | ScalarenvTemp1HighLimitC | read-write | mandatory | When envTemperature1C reaches or exceeds this value a trap will be generated signifying a high temperature condition at temperature sensor 1. The HighLimitC va… |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.1.9 | ScalarenvTemp1LowLimitF | read-write | mandatory | When envTemperature1F reaches or goes below this value a trap will be generated signifying a low temperature condition at temperature sensor 1. The LowLimitF v… |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.1.10 | ScalarenvTemp1LowLimitC | read-write | mandatory | When envTemperature1C reaches or goes below this value a trap will be generated signifying a low temperature condition at temperature sensor 1. The LowLimitC v… |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.2 | NodeenvTemperature2 | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.7.2.1 | ScalarenvTemperature2State | read-write | mandatory | The state of use of Temperature Input Number 2. When a sensor is connected to Temperature Input 2 set State to installed(2) to indicate that the value of envTe… |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.2.2 | ScalarenvTemperature2F | read-only | mandatory | The temperature for sensor 2 in degrees Fahrenheit. |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.2.3 | ScalarenvTemperature2C | read-only | mandatory | The temperature for sensor 2 in degrees Centigrade. |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.2.4 | ScalarenvTemperature2Label | read-write | mandatory | A user-defined text string associated with Temperature Input Number 2. The text string is stored in non-volatile memory. |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.2.5 | ScalarenvTemperature2OffsetF | read-write | mandatory | A temperature correction Offset associated with the envTemperature2F variable. The value of OffsetF is added to the value from Temperature Sensor Number 2 to o… |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.2.6 | ScalarenvTemperature2OffsetC | read-write | mandatory | A temperature correction Offset associated with the envTemperature2C variable. The value of OffsetC is added to the value from Temperature Sensor Number 2 to o… |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.2.7 | ScalarenvTemp2HighLimitF | read-write | mandatory | When envTemperature2F reaches or exceeds this value a trap will be generated signifying a high temperature condition at temperature sensor 2. The HighLimitF va… |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.2.8 | ScalarenvTemp2HighLimitC | read-write | mandatory | When envTemperature2C reaches or exceeds this value a trap will be generated signifying a high temperature condition at temperature sensor 2. The HighLimitC va… |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.2.9 | ScalarenvTemp2LowLimitF | read-write | mandatory | When envTemperature2F reaches or goes below this value a trap will be generated signifying a low temperature condition at temperature sensor 2. The LowLimitF v… |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.2.10 | ScalarenvTemp2LowLimitC | read-write | mandatory | When envTemperature2C reaches or goes below this value a trap will be generated signifying a low temperature condition at temperature sensor 2. The LowLimitC v… |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.3 | NodeenvTemperature3 | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.7.3.1 | ScalarenvTemperature3State | read-write | mandatory | The state of use of Temperature Input Number 3. When a water temperature sensor is connected to Temperature Input 3 set State to waterSensorInstalled(3), when … |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.3.2 | ScalarenvTemperature3F | read-only | mandatory | The temperature for sensor 3 in degrees Fahrenheit. |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.3.3 | ScalarenvTemperature3C | read-only | mandatory | The temperature for sensor 3 in degrees Centigrade. |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.3.4 | ScalarenvTemperature3Label | read-write | mandatory | A user-defined text string associated with Temperature Input Number 3. The text string is stored in non-volatile memory. |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.3.5 | ScalarenvTemperature3OffsetF | read-write | mandatory | A temperature correction Offset associated with the envTemperature3F variable. The value of OffsetF is added to the value from Temperature Sensor Number 3 to o… |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.3.6 | ScalarenvTemperature3OffsetC | read-write | mandatory | A temperature correction Offset associated with the envTemperature3C variable. The value of OffsetC is added to the value from Temperature Sensor Number 3 to o… |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.3.7 | ScalarenvTemp3HighLimitF | read-write | mandatory | When envTemperature3F reaches or exceeds this value a trap will be generated signifying a high temperature condition at temperature sensor 3. The HighLimitF va… |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.3.8 | ScalarenvTemp3HighLimitC | read-write | mandatory | When envTemperature3C reaches or exceeds this value a trap will be generated signifying a high temperature condition at temperature sensor 3. The HighLimitC va… |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.3.9 | ScalarenvTemp3LowLimitF | read-write | mandatory | When envTemperature3F reaches or goes below this value a trap will be generated signifying a low temperature condition at temperature sensor 3. The LowLimitF v… |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.3.10 | ScalarenvTemp3LowLimitC | read-write | mandatory | When envTemperature3C reaches or goes below this value a trap will be generated signifying a low temperature condition at temperature sensor 3. The LowLimitC v… |
| 1.3.6.1.4.1.476.1.2.1.1.1.7.3.11 | ScalarenvTemp3Calibrate | read-write | mandatory | A temperature Offset correction routine associated with Temperature Sensor Number 3. When Calibrate is set to on(1) and State is set to waterSensorInstalled(3)… |
| 1.3.6.1.4.1.476.1.2.1.1.1.8 | NodeenvHumiditySensors | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.8.1 | NodeenvHumidity1 | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.8.1.1 | ScalarenvHumidity1State | read-write | mandatory | The state of use of Humidity Input Number 1. When a sensor is connected to Humidity Input 1 set State to installed(2) to indicate that the value of envHumidity… |
| 1.3.6.1.4.1.476.1.2.1.1.1.8.1.2 | ScalarenvHumidity1RH | read-only | mandatory | The humidity for sensor 1 in percent RH. |
| 1.3.6.1.4.1.476.1.2.1.1.1.8.1.3 | ScalarenvHumidity1Label | read-write | mandatory | A user-defined text string associated with Humidity Input Number 1. The text string is stored in non-volatile memory. |
| 1.3.6.1.4.1.476.1.2.1.1.1.8.1.4 | ScalarenvHumidity1Offset | read-write | mandatory | A humidity correction Offset associated with the envHumidity1RH variable. The value of Offset is added to the value from Humidity Sensor Number 1 to obtain the… |
| 1.3.6.1.4.1.476.1.2.1.1.1.8.1.5 | ScalarenvHumidity1HighLimit | read-write | mandatory | When envHumidity1RH reaches or exceeds this value a trap will be generated signifying a high humidity condition at humidity sensor 1. The HighLimit variable is… |
| 1.3.6.1.4.1.476.1.2.1.1.1.8.1.6 | ScalarenvHumidity1LowLimit | read-write | mandatory | When envHumidity1RH reaches or goes below this value a trap will be generated signifying a low humidity condition at humidity sensor 1. The LowLimit variable i… |
| 1.3.6.1.4.1.476.1.2.1.1.1.8.2 | NodeenvHumidity2 | |||
| 1.3.6.1.4.1.476.1.2.1.1.1.8.2.1 | ScalarenvHumidity2State | read-write | mandatory | The state of use of Humidity Input Number 2. When a sensor is connected to Humidity Input 2 set State to installed(2) to indicate that the value of envHumidity… |
| 1.3.6.1.4.1.476.1.2.1.1.1.8.2.2 | ScalarenvHumidity2RH | read-only | mandatory | The humidity for sensor 2 in percent RH. |
| 1.3.6.1.4.1.476.1.2.1.1.1.8.2.3 | ScalarenvHumidity2Label | read-write | mandatory | A user-defined text string associated with Humidity Input Number 2. The text string is stored in non-volatile memory. |
| 1.3.6.1.4.1.476.1.2.1.1.1.8.2.4 | ScalarenvHumidity2Offset | read-write | mandatory | A humidity correction Offset associated with the envHumidity2RH variable. The value of Offset is added to the value from Humidity Sensor Number 2 to obtain the… |
| 1.3.6.1.4.1.476.1.2.1.1.1.8.2.5 | ScalarenvHumidity2HighLimit | read-write | mandatory | When envHumidity2RH reaches or exceeds this value a trap will be generated signifying a high humidity condition at humidity sensor 2. The HighLimit variable is… |
| 1.3.6.1.4.1.476.1.2.1.1.1.8.2.6 | ScalarenvHumidity2LowLimit | read-write | mandatory | When envHumidity2RH reaches or goes below this value a trap will be generated signifying a low humidity condition at humidity sensor 2. The LowLimit variable i… |
| 1.3.6.1.4.1.476.1.2.1.1.1.11 | NodeenvTraps | |||
| 1.3.6.1.4.1.476.1.2.2 | NodeleExperimental | |||
| 1.3.6.1.4.1.476.1.2.3 | NodelePrivate | |||
| 2 | NodeenvDigInput1TrueTrap | An envDigInput1TrueTrap signifies that envDigitalInput1State has changed from false(2) to true(1). This trap is not generated if envDigInput1TrapEnabled is not… | ||
| 3 | NodeenvDigInput1FalseTrap | An envDigInput1FalseTrap signifies that envDigitalInput1State has changed from true(1) to false(2). This trap is not generated if envDigInput1TrapEnabled is no… | ||
| 4 | NodeenvDigInput2TrueTrap | An envDigInput2TrueTrap signifies that envDigitalInput2State has changed from false(2) to true(1). This trap is not generated if envDigInput2TrapEnabled is not… | ||
| 5 | NodeenvDigInput2FalseTrap | An envDigInput2FalseTrap signifies that envDigitalInput2State has changed from true(1) to false(2). This trap is not generated if envDigInput2TrapEnabled is no… | ||
| 6 | NodeenvDigInput3TrueTrap | An envDigInput3TrueTrap signifies that envDigitalInput3State has changed from false(2) to true(1). This trap is not generated if envDigInput3TrapEnabled is not… | ||
| 7 | NodeenvDigInput3FalseTrap | An envDigInput3FalseTrap signifies that envDigitalInput3State has changed from true(1) to false(2). This trap is not generated if envDigInput3TrapEnabled is no… | ||
| 8 | NodeenvDigInput4TrueTrap | An envDigInput4TrueTrap signifies that envDigitalInput4State has changed from false(2) to true(1). This trap is not generated if envDigInput4TrapEnabled is not… | ||
| 9 | NodeenvDigInput4FalseTrap | An envDigInput4FalseTrap signifies that envDigitalInput4State has changed from true(1) to false(2). This trap is not generated if envDigInput4TrapEnabled is no… | ||
| 10 | NodeenvDigInput5TrueTrap | An envDigInput5TrueTrap signifies that envDigitalInput5State has changed from false(2) to true(1). This trap is not generated if envDigInput5TrapEnabled is not… | ||
| 11 | NodeenvDigInput5FalseTrap | An envDigInput5FalseTrap signifies that envDigitalInput5State has changed from true(1) to false(2). This trap is not generated if envDigInput5TrapEnabled is no… | ||
| 12 | NodeenvDigInput6TrueTrap | An envDigInput6TrueTrap signifies that envDigitalInput6State has changed from false(2) to true(1). This trap is not generated if envDigInput6TrapEnabled is not… | ||
| 13 | NodeenvDigInput6FalseTrap | An envDigInput6FalseTrap signifies that envDigitalInput6State has changed from true(1) to false(2). This trap is not generated if envDigInput6TrapEnabled is no… | ||
| 14 | NodeenvDigInput7TrueTrap | An envDigInput7TrueTrap signifies that envDigitalInput7State has changed from false(2) to true(1). This trap is not generated if envDigInput7TrapEnabled is not… | ||
| 15 | NodeenvDigInput7FalseTrap | An envDigInput7FalseTrap signifies that envDigitalInput7State has changed from true(1) to false(2). This trap is not generated if envDigInput7TrapEnabled is no… | ||
| 16 | NodeenvDigInput8TrueTrap | An envDigInput8TrueTrap signifies that envDigitalInput8State has changed from false(2) to true(1). This trap is not generated if envDigInput8TrapEnabled is not… | ||
| 17 | NodeenvDigInput8FalseTrap | An envDigInput8FalseTrap signifies that envDigitalInput8State has changed from true(1) to false(2). This trap is not generated if envDigInput8TrapEnabled is no… | ||
| 18 | NodeenvDigInput9TrueTrap | An envDigInput9TrueTrap signifies that envDigitalInput9State has changed from false(2) to true(1). This trap is not generated if envDigInput9TrapEnabled is not… | ||
| 19 | NodeenvDigInput9FalseTrap | An envDigInput9FalseTrap signifies that envDigitalInput9State has changed from true(1) to false(2). This trap is not generated if envDigInput9TrapEnabled is no… | ||
| 20 | NodeenvDigInput10TrueTrap | An envDigInput10TrueTrap signifies that envDigitalInput10State has changed from false(2) to true(1). This trap is not generated if envDigInput10TrapEnabled is … | ||
| 21 | NodeenvDigInput10FalseTrap | An envDigInput10FalseTrap signifies that envDigitalInput10State has changed from true(1) to false(2). This trap is not generated if envDigInput10TrapEnabled is… | ||
| 22 | NodeenvTemperature1HighTrap | An envTemperature1HighTrap signifies that the sensor reading has gone above the HighLimit value. | ||
| 23 | NodeenvTemperature1LowTrap | An envTemperature1LowTrap signifies that the sensor reading has gone below the LowLimit value. | ||
| 24 | NodeenvTemperature1NormalTrap | An envTemperature1NormalTrap signifies that the sensor reading has return to the range bounded by HighLimit and LowLimit. | ||
| 25 | NodeenvTemperature2HighTrap | An envTemperature2HighTrap signifies that the sensor reading has gone above the HighLimit value. | ||
| 26 | NodeenvTemperature2LowTrap | An envTemperature2LowTrap signifies that the sensor reading has gone below the LowLimit value. | ||
| 27 | NodeenvTemperature2NormalTrap | An envTemperature2NormalTrap signifies that the sensor reading has return to the range bounded by HighLimit and LowLimit. | ||
| 28 | NodeenvTemperature3HighTrap | An envTemperature3HighTrap signifies that the sensor reading has gone above the HighLimit value. | ||
| 29 | NodeenvTemperature3LowTrap | An envTemperature3LowTrap signifies that the sensor reading has gone below the LowLimit value. | ||
| 30 | NodeenvTemperature3NormalTrap | An envTemperature3NormalTrap signifies that the sensor reading has return to the range bounded by HighLimit and LowLimit. | ||
| 31 | NodeenvHumidity1HighTrap | An envHumidity1HighTrap signifies that the sensor reading has gone above the HighLimit value. | ||
| 32 | NodeenvHumidity1LowTrap | An envHumidity1LowTrap signifies that the sensor reading has gone below the LowLimit value. | ||
| 33 | NodeenvHumidity1NormalTrap | An envHumidity1NormalTrap signifies that the sensor reading has return to the range bounded by HighLimit and LowLimit. | ||
| 34 | NodeenvHumidity2HighTrap | An envHumidity2HighTrap signifies that the sensor reading has gone above the HighLimit value. | ||
| 35 | NodeenvHumidity2LowTrap | An envHumidity2LowTrap signifies that the sensor reading has gone below the LowLimit value. | ||