MIB Viewer

LIEBERT-UPS-MIB

277 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.476Nodeemerson
1.3.6.1.4.1.476.1NodeliebertCorp
1.3.6.1.4.1.476.1.1NodeliebertUps
1.3.6.1.4.1.476.1.1.1NodeluExtensions
1.3.6.1.4.1.476.1.1.1.1NodeluCore
1.3.6.1.4.1.476.1.1.1.1.1NodelcUpsIdent
1.3.6.1.4.1.476.1.1.1.1.1.1ScalarlcUpsIdentManufacturerread-onlyoptionalThe UPS manufacturer.
1.3.6.1.4.1.476.1.1.1.1.1.2ScalarlcUpsIdentModelread-writeoptionalThe UPS Model designation.
1.3.6.1.4.1.476.1.1.1.1.1.3ScalarlcUpsIdentSoftwareVersionread-onlyoptionalThe UPS SNMP Agent software version.
1.3.6.1.4.1.476.1.1.1.1.1.4ScalarlcUpsIdentSpecificread-onlyoptionalA reference to MIB definitions specific to the particular UPS being managed. This object is used to locate the product-specific MIB for this device. If this in…
1.3.6.1.4.1.476.1.1.1.1.1.5ScalarlcUpsIdentFirmwareVersionread-onlyoptionalThe firmware revision level of the UPS.
1.3.6.1.4.1.476.1.1.1.1.1.6ScalarlcUpsIdentSerialNumberread-onlyoptionalThe serial number of the UPS.
1.3.6.1.4.1.476.1.1.1.1.1.7ScalarlcUpsIdentManufactureDateread-onlyoptionalThe date of manufacture of the UPS.
1.3.6.1.4.1.476.1.1.1.1.2NodelcUpsBattery
1.3.6.1.4.1.476.1.1.1.1.2.1ScalarlcUpsBatTimeRemainingread-onlyoptionalThe estimated time to depletion of battery charge. (Unit of measure: Minute)
1.3.6.1.4.1.476.1.1.1.1.2.2ScalarlcUpsBatTemperatureread-onlyoptionalThe battery temperature. (Unit of measure: Degree, Centigrade)
1.3.6.1.4.1.476.1.1.1.1.2.3ScalarlcUpsBatVoltageread-onlyoptionalThe current battery voltage. (Unit of measure: volt)
1.3.6.1.4.1.476.1.1.1.1.2.4ScalarlcUpsBatCurrentread-onlyoptionalThe current battery discharging/charging current. (Unit of measure: Amp)
1.3.6.1.4.1.476.1.1.1.1.2.6ScalarlcUpsBatCapacityread-onlyoptionalThe current battery capacity in percentage of total available.
1.3.6.1.4.1.476.1.1.1.1.2.7ScalarlcUpsBatTotalDischCountsread-onlyoptionalThe number of discharges the UPS has experienced.
1.3.6.1.4.1.476.1.1.1.1.2.8ScalarlcUpsBatCycleDurationInSecondsread-onlyoptionalThe total accumulated discharge time in seconds.
1.3.6.1.4.1.476.1.1.1.1.2.9ScalarlcUpsBatAmpHoursread-onlyoptionalThe number of amp hours withdrawn from battery.
1.3.6.1.4.1.476.1.1.1.1.2.10ScalarlcUpsBatKWhoursread-onlyoptionalThe number of Kilowatt-hours withdrawn from battery.
1.3.6.1.4.1.476.1.1.1.1.2.11ScalarlcUpsBatWattHoursread-onlyoptionalThe number of Watt-hours withdrawn from battery.
1.3.6.1.4.1.476.1.1.1.1.3NodelcUpsInput
1.3.6.1.4.1.476.1.1.1.1.3.1ScalarlcUpsInputFrequencyread-onlyoptionalThe current input frequency. (Unit of measure: Hertz)
1.3.6.1.4.1.476.1.1.1.1.3.2ScalarlcUpsInputBrownOutsread-onlyoptionalThe number of brown-out conditions the UPS has experienced.
1.3.6.1.4.1.476.1.1.1.1.3.3ScalarlcUpsInputBlackOutsread-onlyoptionalThe number of black-out conditions the UPS has experienced.
1.3.6.1.4.1.476.1.1.1.1.3.4ScalarlcUpsInputTransientsread-onlyoptionalThe number of transient (surge and spike) conditions the UPS has experienced.
1.3.6.1.4.1.476.1.1.1.1.3.5ScalarlcUpsInputNumLinesread-onlyoptionalThe number of input lines utilized in this device. This entry indicates the number of rows in the input table.
1.3.6.1.4.1.476.1.1.1.1.3.6TablelcUpsInputTablenot-accessibleoptional
1.3.6.1.4.1.476.1.1.1.1.3.6.1RowlcUpsInputEntrynot-accessibleoptional
1.3.6.1.4.1.476.1.1.1.1.3.6.1.1ColumnlcUpsInputLineread-onlyoptionalThe input Line.
1.3.6.1.4.1.476.1.1.1.1.3.6.1.2ColumnlcUpsInputVoltageread-onlyoptionalThe input voltage. (Unit of measure: Volt)
1.3.6.1.4.1.476.1.1.1.1.3.6.1.3ColumnlcUpsInputCurrentread-onlyoptionalThe input current. (Unit of measure: Amp)
1.3.6.1.4.1.476.1.1.1.1.3.6.1.4ColumnlcUpsInputVAread-onlyoptionalThe input volt-amps.
1.3.6.1.4.1.476.1.1.1.1.4NodelcUpsOutput
1.3.6.1.4.1.476.1.1.1.1.4.1ScalarlcUpsOutputFrequencyread-onlyoptionalThe current output frequency. (Unit of measure: Hertz)
1.3.6.1.4.1.476.1.1.1.1.4.2ScalarlcUpsOutputLoadread-onlyoptionalThe current output load percentage.
1.3.6.1.4.1.476.1.1.1.1.4.3ScalarlcUpsOutputNumLinesread-onlyoptionalThe number of output lines utilized in this device. This entry indicates the number of rows in the output table.
1.3.6.1.4.1.476.1.1.1.1.4.4TablelcUpsOutputTablenot-accessibleoptional
1.3.6.1.4.1.476.1.1.1.1.4.4.1RowlcUpsOutputEntrynot-accessibleoptional
1.3.6.1.4.1.476.1.1.1.1.4.4.1.1ColumnlcUpsOutputLineread-onlyoptionalThe output Line.
1.3.6.1.4.1.476.1.1.1.1.4.4.1.2ColumnlcUpsOutputVoltageread-onlyoptionalThe output voltage. (Unit of measure: Volt)
1.3.6.1.4.1.476.1.1.1.1.4.4.1.3ColumnlcUpsOutputCurrentread-onlyoptionalThe output current. (Unit of measure: Amp)
1.3.6.1.4.1.476.1.1.1.1.4.4.1.4ColumnlcUpsOutputVAread-onlyoptionalThe output volt-amps.
1.3.6.1.4.1.476.1.1.1.1.4.5ScalarlcUpsOutputWattsread-onlyoptionalThe output power in watts.
1.3.6.1.4.1.476.1.1.1.1.5NodelcUpsInverter
1.3.6.1.4.1.476.1.1.1.1.5.1ScalarlcUpsInverterStatusread-onlyoptionalThe state of the inverter. Unknown is returned if the state can not be determined.
1.3.6.1.4.1.476.1.1.1.1.5.2ScalarlcUpsInverterTempread-onlyoptionalThe temperature of the inverter. (Unit of measure: degree, Centigrade)
1.3.6.1.4.1.476.1.1.1.1.6NodelcUpsAlarm
1.3.6.1.4.1.476.1.1.1.1.6.1ScalarlcUpsAlarmsread-onlyoptionalThe current number of alarm conditions.
1.3.6.1.4.1.476.1.1.1.1.6.2TablelcUpsAlarmTablenot-accessibleoptional
1.3.6.1.4.1.476.1.1.1.1.6.2.1RowlcUpsAlarmEntrynot-accessibleoptional
1.3.6.1.4.1.476.1.1.1.1.6.2.1.1ColumnlcUpsAlarmIdread-onlyoptionalA unique identifier for an alarm condition. This value must remain constant between agent initializations.
1.3.6.1.4.1.476.1.1.1.1.6.2.1.2ColumnlcUpsAlarmDescrread-onlyoptionalA reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm con…
1.3.6.1.4.1.476.1.1.1.1.6.2.1.3ColumnlcUpsAlarmTimeread-onlyoptionalThe value of sysUpTime when the alarm condition occured.
1.3.6.1.4.1.476.1.1.1.1.6.3NodelcUpsAlarmConditions
1.3.6.1.4.1.476.1.1.1.1.6.3.1NodelcUpsAlarmLowBatteryWarning
1.3.6.1.4.1.476.1.1.1.1.6.3.2NodelcUpsAlarmLowBatteryShutdown
1.3.6.1.4.1.476.1.1.1.1.6.3.3NodelcUpsAlarmUtilFailed
1.3.6.1.4.1.476.1.1.1.1.6.3.4NodelcUpsAlarmOverTempWarning
1.3.6.1.4.1.476.1.1.1.1.6.3.5NodelcUpsAlarmOverTempShutdown
1.3.6.1.4.1.476.1.1.1.1.6.3.6NodelcUpsAlarmOutputOverloadWarning
1.3.6.1.4.1.476.1.1.1.1.6.3.7NodelcUpsAlarmOutputOverloadShutdown
1.3.6.1.4.1.476.1.1.1.1.6.3.8NodelcUpsAlarmInputOverVoltage
1.3.6.1.4.1.476.1.1.1.1.6.3.9NodelcUpsAlarmBatteryBad
1.3.6.1.4.1.476.1.1.1.1.6.3.10NodelcUpsAlarmOnBattery
1.3.6.1.4.1.476.1.1.1.1.6.3.11NodelcUpsAlarmStopNoticeIssued
1.3.6.1.4.1.476.1.1.1.1.6.3.12NodelcUpsAlarmUpsOff
1.3.6.1.4.1.476.1.1.1.1.6.3.13NodelcUpsAlarmInputFreqError
1.3.6.1.4.1.476.1.1.1.1.6.3.15NodelcUpsAlarmOutputUnderVoltage
1.3.6.1.4.1.476.1.1.1.1.6.3.16NodelcUpsAlarmOutputOverVoltage
1.3.6.1.4.1.476.1.1.1.1.6.3.17NodelcUpsBadBypassPower
1.3.6.1.4.1.476.1.1.1.1.6.3.18NodelcUpsAlarmDCOverVoltageShutdown
1.3.6.1.4.1.476.1.1.1.1.6.3.23NodelcUpsAlarmHardwareShutdown
1.3.6.1.4.1.476.1.1.1.1.6.3.24NodelcUpsAlarmEmergencyXferToBypass
1.3.6.1.4.1.476.1.1.1.1.6.3.25NodelcUpsAlarmInverterFault
1.3.6.1.4.1.476.1.1.1.1.6.3.26NodelcUpsAlarmPhaseRotationError
1.3.6.1.4.1.476.1.1.1.1.6.3.28NodelcUpsAlarmFuseBlown
1.3.6.1.4.1.476.1.1.1.1.6.3.29NodelcUpsAlarmAmbientOverTemp
1.3.6.1.4.1.476.1.1.1.1.6.3.30NodelcUpsAlarmEmergencyPowerOff
1.3.6.1.4.1.476.1.1.1.1.6.3.31NodelcUpsAlarmFanFailed
1.3.6.1.4.1.476.1.1.1.1.6.3.32NodelcUpsAlarmControlPowerFailed
1.3.6.1.4.1.476.1.1.1.1.6.3.33NodelcUpsAlarmReversePower
1.3.6.1.4.1.476.1.1.1.1.6.3.34NodelcUpsAlarmDCgroundFault
1.3.6.1.4.1.476.1.1.1.1.6.3.35NodelcUpsAlarmLoadOnBypass
1.3.6.1.4.1.476.1.1.1.1.6.3.37NodelcUpsAlarmBatteryCbOpen
1.3.6.1.4.1.476.1.1.1.1.6.3.38NodelcUpsAlarmInputCbOpen
1.3.6.1.4.1.476.1.1.1.1.6.3.39NodelcUpsAlarmOutputCbOpen
1.3.6.1.4.1.476.1.1.1.1.6.3.40NodelcUpsAlarmOutputFreqError
1.3.6.1.4.1.476.1.1.1.1.6.3.41NodelcUpsAlarmStaticSwUnable
1.3.6.1.4.1.476.1.1.1.1.6.3.42NodelcUpsAlarmManualResetXfer
1.3.6.1.4.1.476.1.1.1.1.6.3.43NodelcUpsAlarmAutoRexferPrimed
1.3.6.1.4.1.476.1.1.1.1.6.3.44NodelcUpsAlarmBattCycleBuffWarn
1.3.6.1.4.1.476.1.1.1.1.6.3.45NodelcUpsAlarmModuleSummary
1.3.6.1.4.1.476.1.1.1.1.6.3.46NodelcUpsLineCorrectionActive
1.3.6.1.4.1.476.1.1.1.1.7NodelcUpsTest
1.3.6.1.4.1.476.1.1.1.1.7.1ScalarlcUpsTestBatteryread-writeoptionalSetting this variable to 'start' will initiate the battery test. Setting this variable to 'abort' will stop the battery test if the test is in- progress, other…
1.3.6.1.4.1.476.1.1.1.1.7.2ScalarlcUpsTestBatteryStatusread-onlyoptionalThe status of the battery test.
1.3.6.1.4.1.476.1.1.1.1.7.3ScalarlcUpsTestDiagread-writeoptionalSetting this variable to 'start' will initiate the diagnostics test. Setting this variable to 'abort' will stop the diagnostics test if the test is in-progress…
1.3.6.1.4.1.476.1.1.1.1.7.4ScalarlcUpsTestDiagStatusread-onlyoptionalThe status of the diagnostics test.
1.3.6.1.4.1.476.1.1.1.1.8NodelcUpsControl
1.3.6.1.4.1.476.1.1.1.1.8.1ScalarlcUpsControlOutputOffDelayread-writeoptionalSetting this object causes the agent to instruct the UPS to turn off the output after the indicated number of seconds. The agent counts down the number of seco…
1.3.6.1.4.1.476.1.1.1.1.8.2ScalarlcUpsControlOutputOnDelayread-writeoptionalSetting this object causes the agent to instruct the UPS to turn on the output after the indicated number of seconds. The agent counts down the number of secon…
1.3.6.1.4.1.476.1.1.1.1.8.3ScalarlcUpsControlOutputOffTrapDelayread-writeoptionalWhen 'lcUpsControlOutputOffDelay' reaches a value less than or equal to this object's value, an lcUpsOutputOffWarningTrap will be produced and this object will…
1.3.6.1.4.1.476.1.1.1.1.8.4ScalarlcUpsControlOutputOnTrapDelayread-writeoptionalWhen 'lcUpsControlOutputOnDelay' reaches a value less than or equal to this object's value, an lcUpsOutputOnWarningTrap will be produced and this object will b…
1.3.6.1.4.1.476.1.1.1.1.8.5ScalarlcUpsControlUnixShutdownDelayread-writeoptionalSetting this object causes the agent to instruct the UPS to perform a UNIX Shutdown in the indicated number of seconds. The agent counts down the number of sec…
1.3.6.1.4.1.476.1.1.1.1.8.6ScalarlcUpsControlUnixShutdownTrapDelayread-writeoptionalWhen 'lcUpsControlUnixShutdownDelay' reaches a value less than or equal to this object's value, an lcUpsUnixShutdownWarningTrap will be produced and this objec…
1.3.6.1.4.1.476.1.1.1.1.8.7ScalarlcUpsControlCancelCommandsread-writeoptionalSetting this variable to 'cancel' will cause the agent to issue instructions to the UPS to cancel all outstanding commands, such as lcUpsControlOutputOff, lcUp…
1.3.6.1.4.1.476.1.1.1.1.8.8ScalarlcUpsControlRebootAgentDelayread-writeoptionalSetting this object causes the agent to reboot after the indicated number of seconds have expired. The value will count down until the event takes place.
1.3.6.1.4.1.476.1.1.1.1.9NodelcUpsNominal
1.3.6.1.4.1.476.1.1.1.1.9.1ScalarlcUpsNominalOutputVoltageread-writeoptionalThe nominal output voltage. (Unit of measure: volt)
1.3.6.1.4.1.476.1.1.1.1.9.2ScalarlcUpsNominalInputVoltageread-writeoptionalThe nominal input voltage. (Unit of measure: volt)
1.3.6.1.4.1.476.1.1.1.1.9.3ScalarlcUpsNominalOutputVAread-writeoptionalThe nominal Volt-Amp rating.
1.3.6.1.4.1.476.1.1.1.1.9.4ScalarlcUpsNominalOutputWattsread-writeoptionalThe nominal power rating. (Unit of measure: watt)
1.3.6.1.4.1.476.1.1.1.1.9.5ScalarlcUpsNominalOutputFreqread-writeoptionalThe nominal output frequency. (Unit of measure: Hertz)
1.3.6.1.4.1.476.1.1.1.1.9.6ScalarlcUpsNominalInputFreqread-writeoptionalThe nominal input frequency. (Unit of measure: Hertz)
1.3.6.1.4.1.476.1.1.1.1.9.7ScalarlcUpsNominalOutputVaRatingread-writeoptionalThe nominal Volt-Amp rating.
1.3.6.1.4.1.476.1.1.1.1.9.8ScalarlcUpsNominalOutputWattsRatingread-writeoptionalThe nominal power rating. (Unit of measure: watt)
1.3.6.1.4.1.476.1.1.1.1.11NodelcUpsTraps
1.3.6.1.4.1.476.1.1.1.1.11.1NodelcUpsOverloadWarningTrapAn lcUpsOverloadWarningTrap signifies that the UPS has detected an Overload condition where the output load has exceeded the UPS's rated capacity.
1.3.6.1.4.1.476.1.1.1.1.11.2NodelcUpsOverloadShutdownTrapAn lcUpsOverloadShutdownTrap signifies that the UPS has detected an Overload condition where the output load has exceeded the UPS's rated capacity and has shut…
1.3.6.1.4.1.476.1.1.1.1.11.3NodelcUpsOnBatteryTrapAn lcUpsOnBatteryTrap signifies that the UPS is currently on Battery Power.
1.3.6.1.4.1.476.1.1.1.1.11.4NodelcUpsLowBatteryWarningTrapAn lcUpsLowBatteryWarningTrap signifies that the UPS has entered a Low Battery state.
1.3.6.1.4.1.476.1.1.1.1.11.5NodelcUpsLowBatteryShutdownTrapAn lcUpsLowBatteryShutdownTrap signifies that the UPS has shut off the output due to a Low Battery state.
1.3.6.1.4.1.476.1.1.1.1.11.6NodelcUpsUtilPowerFailedTrapAn lcUpsUtilPowerFailedTrap signifies that the utility power input to the UPS has been lost.
1.3.6.1.4.1.476.1.1.1.1.11.7NodelcUpsUtilPowerRestoredTrapAn lcUpsUtilPowerRestoredTrap signifies that the utility power has been restored to the UPS.
1.3.6.1.4.1.476.1.1.1.1.11.8NodelcUpsInputOverVoltageTrapAn lcUpsInputOverVoltageTrap signifies that the UPS has detected a high input voltage condition.
1.3.6.1.4.1.476.1.1.1.1.11.9NodelcUpsOverTempWarningTrapAn lcUpsOverTempWarningTrap signifies that the UPS has detected a excessive temperature condition.
1.3.6.1.4.1.476.1.1.1.1.11.10NodelcUpsOverTempShutdownTrapAn lcUpsOverTempShutdownTrap signifies that the UPS has detected a excessive temperature condition and shut off the output.
1.3.6.1.4.1.476.1.1.1.1.11.11NodelcUpsAlarmTrapAn Alarm condition has occurred and is being reported in the lcUpsAlarmTable.
1.3.6.1.4.1.476.1.1.1.1.11.12NodelcUpsOutputOffTrapAn lcUpsOutputOffTrap is sent when the UPS turns all of its output off, either at the inverter or via a relay.
1.3.6.1.4.1.476.1.1.1.1.11.13NodelcUpsOutputOffWarningTrapAn lcUpsOutputOffWarningTrap is sent when the lcUpsControlOutputOffDelay reaches the value of lcUpsControlOutputOffTrapDelay.
1.3.6.1.4.1.476.1.1.1.1.11.14NodelcUpsOutputOnTrapAn lcUpsOutputOnTrap is sent when the UPS turns all of its output back on, either at the inverter or via a relay.
1.3.6.1.4.1.476.1.1.1.1.11.15NodelcUpsOutputOnWarningTrapAn lcUpsOutputOnWarningTrap is sent when the lcUpsControlOutputOnDelay reaches the value of lcUpsControlOutputOnTrapDelay.
1.3.6.1.4.1.476.1.1.1.1.11.16NodelcUpsUnixShutdownTrapAn lcUpsUnixShutodwnTrap is sent 2 seconds before the UPS is scheduled to perform a Unix Shutdown.
1.3.6.1.4.1.476.1.1.1.1.11.17NodelcUpsUnixShutdownWarningTrapAn lcUpsUnixShutdownWarningTrap is sent when the lcUpsControlUnixShudownDelay reaches the value of lcUpsControlUnixShutdownTrapDelay.
1.3.6.1.4.1.476.1.1.1.1.11.18NodelcUpsReceptOffTrapAn lcUpsReceptOffTrap is sent when the UPS turns an output receptacle off.
1.3.6.1.4.1.476.1.1.1.1.11.19NodelcUpsReceptOffWarningTrapAn lcUpsReceptOffWarningTrap is sent when the lcUpsSwitchedReceptOffDelay reaches the value of lcUpsSwitchedReceptOffTrapDelay.
1.3.6.1.4.1.476.1.1.1.1.11.20NodelcUpsReceptOnTrapAn lcUpsReceptOnTrap is sent when the UPS turns an output receptacle on.
1.3.6.1.4.1.476.1.1.1.1.11.21NodelcUpsReceptOnWarningTrapAn lcUpsReceptOnWarningTrap is sent when the lcUpsSwitchedReceptOnDelay reaches the value of lcUpsSwitchedReceptOnTrapDelay.
1.3.6.1.4.1.476.1.1.1.1.11.22NodelcUpsInputFreqErrorTrapAn ldUpsInputFreqErrorTrap signifies that the UPS has detected that input frequency is outside tolerable variance.
1.3.6.1.4.1.476.1.1.1.1.11.23NodelcUpsDCOverVoltageShutdownTrapAn lcUpsDCOverVoltageShutdownTrap signifies that the UPS has detected that battery voltage is over the tolarable level.
1.3.6.1.4.1.476.1.1.1.1.11.24NodelcUpsOutputOverVoltageTrapAn lcUpsOutputOverVoltageTrap signifies that the UPS has detected that the output voltage is too high.
1.3.6.1.4.1.476.1.1.1.1.11.25NodelcUpsFuseBlownTrapAn lcUpsFuseBlownTrap is sent when the UPS's rectifier or DC capacitor fuse has failed.
1.3.6.1.4.1.476.1.1.1.1.11.26NodelcUpsEmergencyPowerOffTrapAn lcUpsEmergencyPowerOffTrap signifies that the UPS has shut off output due to an emergency condition.
1.3.6.1.4.1.476.1.1.1.1.11.27NodelcUpsControlPowerFailureTrapAn lcUpsControlPowerFailureTrap signifies a failure in the secondary control power.
1.3.6.1.4.1.476.1.1.1.1.11.28NodelcUpsReversePowerTrapAn lcUpsReversePowerTrap signifies that output has been shut off due to a reverse power flow condition.
1.3.6.1.4.1.476.1.1.1.1.11.29NodelcUpsPhaseRotationErrorTrapAn lcUpsPhaseRotationErrorTrap signifies a phase-rotation error in the bypass power.
1.3.6.1.4.1.476.1.1.1.1.11.30NodelcUpsLoadOnBypassTrapAn lcUpsLoadOnBypassTrap signifies that the load has been transferred to bypass power.
1.3.6.1.4.1.476.1.1.1.1.11.31NodelcUpsEmergencyXferToBypassTrapAn lcUpsEmergencyXferToBypassTrap signifies that the UPS has automatically tranferred the load to bypass power.
1.3.6.1.4.1.476.1.1.1.1.11.34NodelcUpsInverterFaultTrapAn lcUpsInverterFaultTrap signifies that the UPS detected a problem with the Inverter.
1.3.6.1.4.1.476.1.1.1.1.12NodelcUpsSwitchedReceptacles
1.3.6.1.4.1.476.1.1.1.1.12.1ScalarlcUpsSwitchedReceptMaxNumread-onlyoptionalThe maximum number of switched receptacles supported by the Ups.
1.3.6.1.4.1.476.1.1.1.1.12.2TablelcUpsSwitchedReceptTablenot-accessibleoptional
1.3.6.1.4.1.476.1.1.1.1.12.2.1RowlcUpsSwitchedReceptEntrynot-accessibleoptional
1.3.6.1.4.1.476.1.1.1.1.12.2.1.1ColumnlcUpsSwitchedReceptIndexread-onlyoptional
1.3.6.1.4.1.476.1.1.1.1.12.2.1.2ColumnlcUpsSwitchedReceptOnDelayread-writeoptionalSetting this object causes the agent to instruct the UPS to turn on a receptacle after the indicated number of seconds. The agent counts down the number of sec…
1.3.6.1.4.1.476.1.1.1.1.12.2.1.3ColumnlcUpsSwitchedReceptOnTrapDelayread-writeoptionalWhen 'lcUpsSwitchedReceptOnDelay' reaches a value less than or equal to this object's value, an lcUpsReceptOnWarningTrap will be produced and this object will …
1.3.6.1.4.1.476.1.1.1.1.12.2.1.4ColumnlcUpsSwitchedReceptOffDelayread-writeoptionalSetting this object causes the agent to instruct the UPS to turn off a receptacle after the indicated number of seconds. The agent counts down the number of se…
1.3.6.1.4.1.476.1.1.1.1.12.2.1.5ColumnlcUpsSwitchedReceptOffTrapDelayread-writeoptionalWhen 'lcUpsSwitchedReceptOffDelay' reaches a value less than or equal to this object's value, an lcUpsReceptOffWarningTrap will be produced and this object wil…
1.3.6.1.4.1.476.1.1.1.1.12.2.1.6ColumnlcUpsSwitchedReceptStatusread-onlyoptionalThe status of the device receptacle. Note that some devices may support Switched of device receptacles as a group only (by using lcUpsSwitchedOutputOffDelay an…
1.3.6.1.4.1.476.1.1.1.1.12.2.1.7ColumnlcUpsSwitchedReceptLabelread-writeoptionalA user-defined text string associated with a switched receptacle. This may be used to describe the load powered from the receptacle. The text string is stored …
1.3.6.1.4.1.476.1.1.1.1.13NodelcUpsBypass
1.3.6.1.4.1.476.1.1.1.1.13.1ScalarlcUpsOnBypassread-onlyoptionalIndicates that the UPS is currently on bypass.
1.3.6.1.4.1.476.1.1.1.1.13.2ScalarlcUpsBypassFrequencyread-onlyoptionalThe current bypass frequency. (Unit of measure: Hertz)
1.3.6.1.4.1.476.1.1.1.1.13.3ScalarlcUpsBypassNumLinesread-onlyoptionalThe number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table.
1.3.6.1.4.1.476.1.1.1.1.13.4TablelcUpsBypassTablenot-accessibleoptional
1.3.6.1.4.1.476.1.1.1.1.13.4.1RowlcUpsBypassEntrynot-accessibleoptional
1.3.6.1.4.1.476.1.1.1.1.13.4.1.1ColumnlcUpsBypassLineread-onlyoptionalThe bypass Line.
1.3.6.1.4.1.476.1.1.1.1.13.4.1.2ColumnlcUpsBypassVoltageread-onlyoptionalThe bypass voltage. (Unit of measure: Volt)
1.3.6.1.4.1.476.1.1.1.1.13.4.1.3ColumnlcUpsBypassCurrentread-onlyoptionalThe bypass current. (Unit of measure: Amp)
1.3.6.1.4.1.476.1.1.1.1.14NodelcUpsConfig
1.3.6.1.4.1.476.1.1.1.1.14.1ScalarlcUpsConfigTyperead-onlyoptionalIndicates the UPS topology.
1.3.6.1.4.1.476.1.1.1.1.14.2ScalarlcUpsConfigBypassInstalledread-onlyoptionalIndicates if a bypass is installed in the UPS.
1.3.6.1.4.1.476.1.1.1.1.14.3ScalarlcUpsConfigModuleCountread-onlyoptionalA number identifying how many multi-module UPS are connected to the System Control Cabinet.
1.3.6.1.4.1.476.1.1.1.1.14.4ScalarlcUpsConfigCurrentModuleread-writeoptionalA number identifying which module of a multi-module UPS is currently being monitored.
1.3.6.1.4.1.476.1.1.1.1.14.5ScalarlcUpsConfigAudibleStatusread-writeoptionalThe requested state of the audible alarm. When in the disabled state, the audible alarm should never sound. The enabled state is self-describing. Setting this …
1.3.6.1.4.1.476.1.1.1.1.14.6ScalarlcUpsConfigLowBattTimeread-writeoptionalThe value of lcUpsBatTimeRemaining at which a lowBatteryWarning condition is declared. (Unit of measure: Minute)
1.3.6.1.4.1.476.1.1.1.1.14.7ScalarlcUpsConfigAutoRestartread-writeoptionalSetting this object will start the output after the indicated number of ticks (1 tick = 10 seconds), including starting the UPS, if necessary. Setting this obj…
1.3.6.1.4.1.476.1.1.1.2NodeluUPStationS
1.3.6.1.4.1.476.1.1.1.2.1NodelsUpsIdent
1.3.6.1.4.1.476.1.1.1.2.1.1ScalarlsUpsIdentFirmwareVersionread-onlyoptionalThe firmware revision level of the UPS.
1.3.6.1.4.1.476.1.1.1.2.6NodelsUpsAlarm
1.3.6.1.4.1.476.1.1.1.2.6.1NodelsUpsAlarmConditions
1.3.6.1.4.1.476.1.1.1.2.6.1.1NodelsUpsAlarmCheckAirFilter
1.3.6.1.4.1.476.1.1.1.2.11NodelsUpsTraps
1.3.6.1.4.1.476.1.1.1.2.11.1NodelsUpsCheckAirFilterTrapAn lsUpsCheckAirFilterTrap signifies that the programmed time interval for checking the air filter has passed and it is time to check the air filter.
1.3.6.1.4.1.476.1.1.1.2.12NodelsUpsConfig
1.3.6.1.4.1.476.1.1.1.2.12.1ScalarlsUpsConfigBypassInstalledread-onlyoptionalIndicates if a bypass is installed in the UPS.
1.3.6.1.4.1.476.1.1.1.2.13NodelsUpsBypass
1.3.6.1.4.1.476.1.1.1.2.13.1ScalarlsUpsOnBypassread-onlyoptionalIndicates that the UPS is currently on bypass.
1.3.6.1.4.1.476.1.1.1.2.13.2ScalarlsUpsBypassFrequencyread-onlyoptionalThe current bypass frequency. (Unit of measure: Hertz)
1.3.6.1.4.1.476.1.1.1.2.13.3ScalarlsUpsBypassNumLinesread-onlyoptionalThe number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table.
1.3.6.1.4.1.476.1.1.1.2.13.4TablelsUpsBypassTablenot-accessibleoptional
1.3.6.1.4.1.476.1.1.1.2.13.4.1RowlsUpsBypassEntrynot-accessibleoptional
1.3.6.1.4.1.476.1.1.1.2.13.4.1.1ColumnlsUpsBypassLineread-onlyoptionalThe bypass Line.
1.3.6.1.4.1.476.1.1.1.2.13.4.1.2ColumnlsUpsBypassVoltageread-onlyoptionalThe bypass voltage. (Unit of measure: Volt)
1.3.6.1.4.1.476.1.1.1.2.13.4.1.3ColumnlsUpsBypassCurrentread-onlyoptionalThe bypass current. (Unit of measure: Amp)
1.3.6.1.4.1.476.1.1.1.3NodeluUPStationD
1.3.6.1.4.1.476.1.1.1.3.3NodeldUpsInput
1.3.6.1.4.1.476.1.1.1.3.3.1ScalarldUpsInputMaxVoltsSinceLastPollread-onlyoptionalThe maximum input voltage encountered since the object was last retrieved. Note: if there are multiple managers talking to the same agent, the use of this obje…
1.3.6.1.4.1.476.1.1.1.3.3.2ScalarldUpsInputMinVoltsSinceLastPollread-onlyoptionalThe minimum input voltage encountered since the object was last retrieved. Note: if there are multiple managers talking to the same agent, the use of this obje…
1.3.6.1.4.1.476.1.1.1.3.4NodeldUpsOutput
1.3.6.1.4.1.476.1.1.1.3.4.1ScalarldUpsOutputMaxVoltsSinceLastPollread-onlyoptionalThe maximum output voltage encountered since the object was last retrieved. Note: if there are multiple managers talking to the same agent, the use of this obj…
1.3.6.1.4.1.476.1.1.1.3.4.2ScalarldUpsOutputMinVoltsSinceLastPollread-onlyoptionalThe minimum output voltage encountered since the object was last retrieved. Note: if there are multiple managers talking to the same agent, the use of this obj…
1.3.6.1.4.1.476.1.1.1.3.6NodeldUpsAlarm
1.3.6.1.4.1.476.1.1.1.3.6.1NodeldUpsAlarmConditions
1.3.6.1.4.1.476.1.1.1.3.6.1.1NodeldUpsAlarmDCOverVoltageShutdown
1.3.6.1.4.1.476.1.1.1.3.6.1.2NodeldUpsAlarmOutputShortShutdown
1.3.6.1.4.1.476.1.1.1.3.6.1.3NodeldUpsAlarmLNReversedShutdown
1.3.6.1.4.1.476.1.1.1.3.6.1.4NodeldUpsAlarmImminentShutdown
1.3.6.1.4.1.476.1.1.1.3.6.1.5NodeldUpsAlarmInputFreqError
1.3.6.1.4.1.476.1.1.1.3.6.1.6NodeldUpsAlarmBoostOn
1.3.6.1.4.1.476.1.1.1.3.6.1.7NodeldUpsAlarmReplaceBattery
1.3.6.1.4.1.476.1.1.1.3.6.1.8NodeldUpsAlarmOutputOverVoltage
1.3.6.1.4.1.476.1.1.1.3.6.1.9NodeldUpsAlarmOutputUnderVoltage
1.3.6.1.4.1.476.1.1.1.3.6.1.10NodeldUpsAlarmChargerFailed
1.3.6.1.4.1.476.1.1.1.3.11NodeldUpsTraps
1.3.6.1.4.1.476.1.1.1.3.11.1NodeldUpsDCOverVoltageShutdownTrapAn ldUpsDCOverVoltageShutdownTrap signifies that the UPS has detected that battery voltage is over the tolarable level.
1.3.6.1.4.1.476.1.1.1.3.11.2NodeldUpsOutputShortShutdownTrapAn ldUpsOutputShortShutdownTrap signifies that the UPS has detected a short circuit across the output.
1.3.6.1.4.1.476.1.1.1.3.11.3NodeldUpsLNReversedShutdownTrapAn ldUpsLNReversedShutdownTrap signifies that the UPS has detected that Line and Neutral have been reversed.
1.3.6.1.4.1.476.1.1.1.3.11.4NodeldUpsImminentShutdownTrapAn ldUpsImminentShutdownTrap signifies that the UPS is about to turn off output power.
1.3.6.1.4.1.476.1.1.1.3.11.5NodeldUpsInputFreqErrorTrapAn ldUpsInputFreqErrorTrap signifies that the UPS has detected that input frequency is outside tolerable variance.
1.3.6.1.4.1.476.1.1.1.3.11.6NodeldUpsOutputOverVoltageTrapAn ldUpsOutputOverVoltageTrap signifies that the UPS has detected that the output voltage is too high.
1.3.6.1.4.1.476.1.1.1.3.11.7NodeldUpsOutputUnderVoltageTrapAn ldUpsOutputUnderVoltageTrap signifies that the UPS has detected that the output voltage is too low.
1.3.6.1.4.1.476.1.1.1.3.11.8NodeldUpsChargerFailedTrapAn ldUpsChargerFailedTrap signifies that the UPS has detected that the battery charger has failed.
1.3.6.1.4.1.476.1.1.1.4NodeluUPStationG
1.3.6.1.4.1.476.1.1.1.4.6NodelgUpsAlarm
1.3.6.1.4.1.476.1.1.1.4.6.1NodelgUpsAlarmConditions
1.3.6.1.4.1.476.1.1.1.4.6.1.1NodelgUpsAlarmDCOverVoltageShutdown
1.3.6.1.4.1.476.1.1.1.4.6.1.2NodelgUpsAlarmOutputShortShutdown
1.3.6.1.4.1.476.1.1.1.4.6.1.3NodelgUpsAlarmLNReversedShutdown
1.3.6.1.4.1.476.1.1.1.4.6.1.4NodelgUpsAlarmRemoteShutdown
1.3.6.1.4.1.476.1.1.1.4.6.1.5NodelgUpsAlarmInputUVOnStartup
1.3.6.1.4.1.476.1.1.1.4.6.1.6NodelgUpsAlarmPFCFailedOnStartup
1.3.6.1.4.1.476.1.1.1.4.11NodelgUpsTraps
1.3.6.1.4.1.476.1.1.1.4.11.1NodelgUpsDCOverVoltageShutdownTrapAn lgUpsDCOverVoltageShutdownTrap signifies that the UPS has detected that battery voltage is over the nominal level.
1.3.6.1.4.1.476.1.1.1.4.11.2NodelgUpsOutputShortShutdownTrapAn lgUpsOutputShortShutdownTrap signifies that the UPS has detected a short circuit across the output.
1.3.6.1.4.1.476.1.1.1.4.11.3NodelgUpsLNReversedShutdownTrapAn lgUpsLNReversedShutdownTrap signifies that the UPS has detected that Line and Neutral have been reversed.
1.3.6.1.4.1.476.1.1.1.4.11.4NodelgUpsInputUVOnStartupTrapAn lgUpsInputUVOnStartupTrap signifies that the UPS detected a low voltage condition upon system startup.
1.3.6.1.4.1.476.1.1.1.5NodeluSeries300
1.3.6.1.4.1.476.1.1.1.6NodeluExternal
1.3.6.1.4.1.476.1.1.1.7NodeluUPStationS3
1.3.6.1.4.1.476.1.1.1.8NodeluSeries200
1.3.6.1.4.1.476.1.1.1.8.3NodeluSeries200Input
1.3.6.1.4.1.476.1.1.1.8.3.1ScalarluSeries200InputMaxVoltsSinceLastPollread-onlyoptionalThe maximum input voltage encountered since the object was last retrieved. Note: if there are multiple managers talking to the same agent, the use of this obje…
1.3.6.1.4.1.476.1.1.1.8.3.2ScalarluSeries200InputMinVoltsSinceLastPollread-onlyoptionalThe minimum input voltage encountered since the object was last retrieved. Note: if there are multiple managers talking to the same agent, the use of this obje…
1.3.6.1.4.1.476.1.1.1.8.6NodeluSeries200Alarm
1.3.6.1.4.1.476.1.1.1.8.6.1NodeluSeries200AlarmConditions
1.3.6.1.4.1.476.1.1.1.8.6.1.1NodeluSeries200AlarmInputFreqError
1.3.6.1.4.1.476.1.1.1.8.12NodeluSeries200Config
1.3.6.1.4.1.476.1.1.1.8.12.1ScalarluSeries200ConfigBypassInstalledread-onlyoptionalIndicates if a bypass is installed in the UPS.
1.3.6.1.4.1.476.1.1.1.8.12.2ScalarluSeries200ConfigFrequencyChangerModelread-onlyoptionalIndicates whether this AP200 model is a frequency changer model.
1.3.6.1.4.1.476.1.1.1.8.13NodeluSeries200Bypass
1.3.6.1.4.1.476.1.1.1.8.13.1ScalarluSeries200OnBypassread-onlyoptionalIndicates that the UPS is currently on bypass.
1.3.6.1.4.1.476.1.1.1.10NodeluSeries4300
1.3.6.1.4.1.476.1.1.1.10.1Nodels43cUpsIdent
1.3.6.1.4.1.476.1.1.1.10.1.1Scalarls43cUpsIdentFirmwareVersionread-onlyoptionalThe firmware revision level of the UPS.
1.3.6.1.4.1.476.1.1.1.10.12Nodels43cUpsConfig
1.3.6.1.4.1.476.1.1.1.10.12.1Scalarls43cUpsConfigBypassInstalledread-onlyoptionalIndicates if a bypass is installed in the UPS.
1.3.6.1.4.1.476.1.1.1.10.13Nodels43cUpsBypass
1.3.6.1.4.1.476.1.1.1.10.13.1Scalarls43cUpsOnBypassread-onlyoptionalIndicates that the UPS is currently on bypass.
1.3.6.1.4.1.476.1.1.1.10.13.2Scalarls43cUpsBypassFrequencyread-onlyoptionalThe current bypass frequency. (Unit of measure: Hertz)
1.3.6.1.4.1.476.1.1.1.10.13.3Scalarls43cUpsBypassNumLinesread-onlyoptionalThe number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table.
1.3.6.1.4.1.476.1.1.1.10.13.4Tablels43cUpsBypassTablenot-accessibleoptional
1.3.6.1.4.1.476.1.1.1.10.13.4.1Rowls43cUpsBypassEntrynot-accessibleoptional
1.3.6.1.4.1.476.1.1.1.10.13.4.1.1Columnls43cUpsBypassLineread-onlyoptionalThe bypass Line.
1.3.6.1.4.1.476.1.1.1.10.13.4.1.2Columnls43cUpsBypassVoltageread-onlyoptionalThe bypass voltage. (Unit of measure: Volt)
1.3.6.1.4.1.476.1.1.1.10.13.4.1.3Columnls43cUpsBypassCurrentread-onlyoptionalThe bypass current. (Unit of measure: Amp)
1.3.6.1.4.1.476.1.1.1.11NodeluUpsModule
1.3.6.1.4.1.476.1.1.1.12NodeluSystemCabinet
1.3.6.1.4.1.476.1.1.1.14NodeluUPStationGxt
1.3.6.1.4.1.476.1.1.1.15NodeluPowerSure
1.3.6.1.4.1.476.1.1.2NodeluExperimental
1.3.6.1.4.1.476.1.1.3NodeluPrivate