LIEBERT-UPSTATION-S3-UPS-MIB
130 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | Counter enterprises Gauge TimeTicks |
| RFC1213-MIB | DisplayString sysUpTime |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.476 | Nodeemerson | |||
| 1.3.6.1.4.1.476.1 | NodeliebertCorp | |||
| 1.3.6.1.4.1.476.1.1 | NodeliebertUps | |||
| 1.3.6.1.4.1.476.1.1.1 | NodeluExtensions | |||
| 1.3.6.1.4.1.476.1.1.1.1 | NodeluCore | |||
| 1.3.6.1.4.1.476.1.1.1.1.1 | NodelcUpsIdent | |||
| 1.3.6.1.4.1.476.1.1.1.1.1.1 | ScalarlcUpsIdentManufacturer | read-only | optional | The UPS manufacturer. |
| 1.3.6.1.4.1.476.1.1.1.1.1.2 | ScalarlcUpsIdentModel | read-write | optional | The UPS Model designation. |
| 1.3.6.1.4.1.476.1.1.1.1.1.3 | ScalarlcUpsIdentSoftwareVersion | read-only | optional | The UPS SNMP Agent software version. |
| 1.3.6.1.4.1.476.1.1.1.1.1.4 | ScalarlcUpsIdentSpecific | read-only | optional | A reference to MIB definitions specific to the particular UPS being managed. This object is used to locate the product-specific MIB for this device. If this in… |
| 1.3.6.1.4.1.476.1.1.1.1.2 | NodelcUpsBattery | |||
| 1.3.6.1.4.1.476.1.1.1.1.2.1 | ScalarlcUpsBatTimeRemaining | read-only | optional | The estimated time to depletion of battery charge. (Unit of measure: Minute) |
| 1.3.6.1.4.1.476.1.1.1.1.2.2 | ScalarlcUpsBatTemperature | read-only | optional | The battery temperature. (Unit of measure: Degree, Centigrade) |
| 1.3.6.1.4.1.476.1.1.1.1.2.3 | ScalarlcUpsBatVoltage | read-only | optional | The current battery voltage. (Unit of measure: volt) |
| 1.3.6.1.4.1.476.1.1.1.1.2.4 | ScalarlcUpsBatCurrent | read-only | optional | The current battery discharging/charging current. (Unit of measure: Amp) |
| 1.3.6.1.4.1.476.1.1.1.1.3 | NodelcUpsInput | |||
| 1.3.6.1.4.1.476.1.1.1.1.3.1 | ScalarlcUpsInputFrequency | read-only | optional | The current input frequency. (Unit of measure: Hertz) |
| 1.3.6.1.4.1.476.1.1.1.1.3.2 | ScalarlcUpsInputBrownOuts | read-only | optional | The number of brown-out conditions the UPS has experienced. |
| 1.3.6.1.4.1.476.1.1.1.1.3.3 | ScalarlcUpsInputBlackOuts | read-only | optional | The number of black-out conditions the UPS has experienced. |
| 1.3.6.1.4.1.476.1.1.1.1.3.4 | ScalarlcUpsInputTransients | read-only | optional | The number of transient (surge and spike) conditions the UPS has experienced. |
| 1.3.6.1.4.1.476.1.1.1.1.3.5 | ScalarlcUpsInputNumLines | read-only | optional | The number of input lines utilized in this device. This entry indicates the number of rows in the input table. |
| 1.3.6.1.4.1.476.1.1.1.1.3.6 | TablelcUpsInputTable | not-accessible | optional | |
| 1.3.6.1.4.1.476.1.1.1.1.3.6.1 | RowlcUpsInputEntry | not-accessible | optional | |
| 1.3.6.1.4.1.476.1.1.1.1.3.6.1.1 | ColumnlcUpsInputLine | read-only | optional | The input Line. |
| 1.3.6.1.4.1.476.1.1.1.1.3.6.1.2 | ColumnlcUpsInputVoltage | read-only | optional | The input voltage. (Unit of measure: Volt) |
| 1.3.6.1.4.1.476.1.1.1.1.3.6.1.3 | ColumnlcUpsInputCurrent | read-only | optional | The input current. (Unit of measure: Amp) |
| 1.3.6.1.4.1.476.1.1.1.1.3.6.1.4 | ColumnlcUpsInputVA | read-only | optional | The input volt-amps. |
| 1.3.6.1.4.1.476.1.1.1.1.4 | NodelcUpsOutput | |||
| 1.3.6.1.4.1.476.1.1.1.1.4.1 | ScalarlcUpsOutputFrequency | read-only | optional | The current output frequency. (Unit of measure: Hertz) |
| 1.3.6.1.4.1.476.1.1.1.1.4.2 | ScalarlcUpsOutputLoad | read-only | optional | The current output load percentage. |
| 1.3.6.1.4.1.476.1.1.1.1.4.3 | ScalarlcUpsOutputNumLines | read-only | optional | The number of output lines utilized in this device. This entry indicates the number of rows in the output table. |
| 1.3.6.1.4.1.476.1.1.1.1.4.4 | TablelcUpsOutputTable | not-accessible | optional | |
| 1.3.6.1.4.1.476.1.1.1.1.4.4.1 | RowlcUpsOutputEntry | not-accessible | optional | |
| 1.3.6.1.4.1.476.1.1.1.1.4.4.1.1 | ColumnlcUpsOutputLine | read-only | optional | The output Line. |
| 1.3.6.1.4.1.476.1.1.1.1.4.4.1.2 | ColumnlcUpsOutputVoltage | read-only | optional | The output voltage. (Unit of measure: Volt) |
| 1.3.6.1.4.1.476.1.1.1.1.4.4.1.3 | ColumnlcUpsOutputCurrent | read-only | optional | The output current. (Unit of measure: Amp) |
| 1.3.6.1.4.1.476.1.1.1.1.4.4.1.4 | ColumnlcUpsOutputVA | read-only | optional | The output volt-amps. |
| 1.3.6.1.4.1.476.1.1.1.1.5 | NodelcUpsInverter | |||
| 1.3.6.1.4.1.476.1.1.1.1.5.1 | ScalarlcUpsInverterStatus | read-only | optional | The state of the inverter. Unknown is returned if the state can not be determined. |
| 1.3.6.1.4.1.476.1.1.1.1.5.2 | ScalarlcUpsInverterTemp | read-only | optional | The temperature of the inverter. (Unit of measure: degree, Centigrade) |
| 1.3.6.1.4.1.476.1.1.1.1.6 | NodelcUpsAlarm | |||
| 1.3.6.1.4.1.476.1.1.1.1.6.1 | ScalarlcUpsAlarms | read-only | optional | The current number of alarm conditions. |
| 1.3.6.1.4.1.476.1.1.1.1.6.2 | TablelcUpsAlarmTable | not-accessible | optional | |
| 1.3.6.1.4.1.476.1.1.1.1.6.2.1 | RowlcUpsAlarmEntry | not-accessible | optional | |
| 1.3.6.1.4.1.476.1.1.1.1.6.2.1.1 | ColumnlcUpsAlarmId | read-only | optional | A unique identifier for an alarm condition. This value must remain constant between agent initializations. |
| 1.3.6.1.4.1.476.1.1.1.1.6.2.1.2 | ColumnlcUpsAlarmDescr | read-only | optional | A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm con… |
| 1.3.6.1.4.1.476.1.1.1.1.6.2.1.3 | ColumnlcUpsAlarmTime | read-only | optional | The value of sysUpTime when the alarm condition occured. |
| 1.3.6.1.4.1.476.1.1.1.1.6.3 | NodelcUpsAlarmConditions | |||
| 1.3.6.1.4.1.476.1.1.1.1.6.3.1 | NodelcUpsAlarmLowBatteryWarning | |||
| 1.3.6.1.4.1.476.1.1.1.1.6.3.2 | NodelcUpsAlarmLowBatteryShutdown | |||
| 1.3.6.1.4.1.476.1.1.1.1.6.3.3 | NodelcUpsAlarmUtilFailed | |||
| 1.3.6.1.4.1.476.1.1.1.1.6.3.4 | NodelcUpsAlarmOverTempWarning | |||
| 1.3.6.1.4.1.476.1.1.1.1.6.3.6 | NodelcUpsAlarmOutputOverloadWarning | |||
| 1.3.6.1.4.1.476.1.1.1.1.6.3.8 | NodelcUpsAlarmInputOverVoltage | |||
| 1.3.6.1.4.1.476.1.1.1.1.6.3.9 | NodelcUpsAlarmBatteryBad | |||
| 1.3.6.1.4.1.476.1.1.1.1.6.3.10 | NodelcUpsAlarmOnBattery | |||
| 1.3.6.1.4.1.476.1.1.1.1.6.3.12 | NodelcUpsAlarmUpsOff | |||
| 1.3.6.1.4.1.476.1.1.1.1.7 | NodelcUpsTest | |||
| 1.3.6.1.4.1.476.1.1.1.1.7.1 | ScalarlcUpsTestBattery | read-write | optional | Setting this variable to 'start' will initiate the battery test. Setting this variable to 'abort' will stop the battery test if the test is in- progress, other… |
| 1.3.6.1.4.1.476.1.1.1.1.7.2 | ScalarlcUpsTestBatteryStatus | read-only | optional | The status of the battery test. |
| 1.3.6.1.4.1.476.1.1.1.1.7.3 | ScalarlcUpsTestDiag | read-write | optional | Setting this variable to 'start' will initiate the diagnostics test. Setting this variable to 'abort' will stop the diagnostics test if the test is in-progress… |
| 1.3.6.1.4.1.476.1.1.1.1.7.4 | ScalarlcUpsTestDiagStatus | read-only | optional | The status of the diagnostics test. |
| 1.3.6.1.4.1.476.1.1.1.1.8 | NodelcUpsControl | |||
| 1.3.6.1.4.1.476.1.1.1.1.8.1 | ScalarlcUpsControlOutputOffDelay | read-write | optional | Setting this object causes the agent to instruct the UPS to turn off the output after the indicated number of seconds. The agent counts down the number of seco… |
| 1.3.6.1.4.1.476.1.1.1.1.8.2 | ScalarlcUpsControlOutputOnDelay | read-write | optional | Setting this object causes the agent to instruct the UPS to turn on the output after the indicated number of seconds. The agent counts down the number of secon… |
| 1.3.6.1.4.1.476.1.1.1.1.8.3 | ScalarlcUpsControlOutputOffTrapDelay | read-write | optional | When 'lcUpsControlOutputOffDelay' reaches a value less than or equal to this object's value, an lcUpsOutputOffWarningTrap will be produced and this object will… |
| 1.3.6.1.4.1.476.1.1.1.1.8.4 | ScalarlcUpsControlOutputOnTrapDelay | read-write | optional | When 'lcUpsControlOutputOnDelay' reaches a value less than or equal to this object's value, an lcUpsOutputOnWarningTrap will be produced and this object will b… |
| 1.3.6.1.4.1.476.1.1.1.1.8.5 | ScalarlcUpsControlUnixShutdownDelay | read-write | optional | Setting this object causes the agent to instruct the UPS to perform a UNIX Shutdown in the indicated number of seconds. The agent counts down the number of sec… |
| 1.3.6.1.4.1.476.1.1.1.1.8.6 | ScalarlcUpsControlUnixShutdownTrapDelay | read-write | optional | When 'lcUpsControlUnixShutdownDelay' reaches a value less than or equal to this object's value, an lcUpsUnixShutdownWarningTrap will be produced and this objec… |
| 1.3.6.1.4.1.476.1.1.1.1.8.7 | ScalarlcUpsControlCancelCommands | read-write | optional | Setting this variable to 'cancel' will cause the agent to issue instructions to the UPS to cancel all outstanding commands, such as lcUpsControlOutputOff, lcUp… |
| 1.3.6.1.4.1.476.1.1.1.1.8.8 | ScalarlcUpsControlRebootAgentDelay | read-write | optional | Setting this object causes the agent to reboot after the indicated number of seconds have expired. The value will count down until the event takes place. The c… |
| 1.3.6.1.4.1.476.1.1.1.1.9 | NodelcUpsNominal | |||
| 1.3.6.1.4.1.476.1.1.1.1.9.1 | ScalarlcUpsNominalOutputVoltage | read-write | optional | The nominal output voltage. (Unit of measure: volt) |
| 1.3.6.1.4.1.476.1.1.1.1.9.2 | ScalarlcUpsNominalInputVoltage | read-write | optional | The nominal input voltage. (Unit of measure: volt) |
| 1.3.6.1.4.1.476.1.1.1.1.9.3 | ScalarlcUpsNominalOutputVA | read-write | optional | The nominal Volt-Amp rating. |
| 1.3.6.1.4.1.476.1.1.1.1.9.4 | ScalarlcUpsNominalOutputWatts | read-write | optional | The nominal power rating. (Unit of measure: watt) |
| 1.3.6.1.4.1.476.1.1.1.1.9.5 | ScalarlcUpsNominalOutputFreq | read-write | optional | The nominal output frequency. (Unit of measure: Hertz) |
| 1.3.6.1.4.1.476.1.1.1.1.9.6 | ScalarlcUpsNominalInputFreq | read-write | optional | The nominal input frequency. (Unit of measure: Hertz) |
| 1.3.6.1.4.1.476.1.1.1.1.11 | NodelcUpsTraps | |||
| 1.3.6.1.4.1.476.1.1.1.1.11.1 | NodelcUpsOverloadWarningTrap | An lcUpsOverloadWarningTrap signifies that the UPS has detected an Overload condition where the output load has exceeded the UPS's rated capacity. | ||
| 1.3.6.1.4.1.476.1.1.1.1.11.3 | NodelcUpsOnBatteryTrap | An lcUpsOnBatteryTrap signifies that the UPS is currently on Battery Power. | ||
| 1.3.6.1.4.1.476.1.1.1.1.11.4 | NodelcUpsLowBatteryWarningTrap | An lcUpsLowBatteryWarningTrap signifies that the UPS has entered a Low Battery state. | ||
| 1.3.6.1.4.1.476.1.1.1.1.11.6 | NodelcUpsUtilPowerFailedTrap | An lcUpsUtilPowerFailedTrap signifies that the utility power input to the UPS has been lost. | ||
| 1.3.6.1.4.1.476.1.1.1.1.11.7 | NodelcUpsUtilPowerRestoredTrap | An lcUpsUtilPowerRestoredTrap signifies that the utility power has been restored to the UPS. | ||
| 1.3.6.1.4.1.476.1.1.1.1.11.8 | NodelcUpsInputOverVoltageTrap | An lcUpsInputOverVoltageTrap signifies that the UPS has detected a high input voltage condition. | ||
| 1.3.6.1.4.1.476.1.1.1.1.11.9 | NodelcUpsOverTempWarningTrap | An lcUpsOverTempWarningTrap signifies that the UPS has detected a excessive temperature condition. | ||
| 1.3.6.1.4.1.476.1.1.1.1.11.11 | NodelcUpsAlarmTrap | An Alarm condition has occurred and is being reported in the lcUpsAlarmTable. | ||
| 1.3.6.1.4.1.476.1.1.1.1.11.12 | NodelcUpsOutputOffTrap | An lcUpsOutputOffTrap is sent when the UPS turns all of its output off, either at the inverter or via a relay. | ||
| 1.3.6.1.4.1.476.1.1.1.1.11.13 | NodelcUpsOutputOffWarningTrap | An lcUpsOutputOffWarningTrap is sent when the lcUpsControlOutputOffDelay reaches the value of lcUpsControlOutputOffTrapDelay. | ||
| 1.3.6.1.4.1.476.1.1.1.1.11.14 | NodelcUpsOutputOnTrap | An lcUpsOutputOnTrap is sent when the UPS turns all of its output back on, either at the inverter or via a relay. | ||
| 1.3.6.1.4.1.476.1.1.1.1.11.15 | NodelcUpsOutputOnWarningTrap | An lcUpsOutputOnWarningTrap is sent when the lcUpsControlOutputOnDelay reaches the value of lcUpsControlOutputOnTrapDelay. | ||
| 1.3.6.1.4.1.476.1.1.1.1.11.16 | NodelcUpsUnixShutdownTrap | An lcUpsUnixShutodwnTrap is sent 2 seconds before the UPS is scheduled to perform a Unix Shutdown. | ||
| 1.3.6.1.4.1.476.1.1.1.1.11.17 | NodelcUpsUnixShutdownWarningTrap | An lcUpsUnixShutdownWarningTrap is sent when the lcUpsControlUnixShudownDelay reaches the value of lcUpsControlUnixShutdownTrapDelay. | ||
| 1.3.6.1.4.1.476.1.1.1.1.11.18 | NodelcUpsReceptOffTrap | An lcUpsReceptOffTrap is sent when the UPS turns an output receptacle off. | ||
| 1.3.6.1.4.1.476.1.1.1.1.11.19 | NodelcUpsReceptOffWarningTrap | An lcUpsReceptOffWarningTrap is sent when the lcUpsSwitchedReceptOffDelay reaches the value of lcUpsSwitchedReceptOffTrapDelay. | ||
| 1.3.6.1.4.1.476.1.1.1.1.11.20 | NodelcUpsReceptOnTrap | An lcUpsReceptOnTrap is sent when the UPS turns an output receptacle on. | ||
| 1.3.6.1.4.1.476.1.1.1.1.11.21 | NodelcUpsReceptOnWarningTrap | An lcUpsReceptOnWarningTrap is sent when the lcUpsSwitchedReceptOnDelay reaches the value of lcUpsSwitchedReceptOnTrapDelay. | ||
| 1.3.6.1.4.1.476.1.1.1.1.12 | NodelcUpsSwitchedReceptacles | |||
| 1.3.6.1.4.1.476.1.1.1.1.12.1 | ScalarlcUpsSwitchedReceptMaxNum | read-only | optional | The maximum number of switched receptacles supported by the Ups. |
| 1.3.6.1.4.1.476.1.1.1.1.12.2 | TablelcUpsSwitchedReceptTable | not-accessible | optional | |
| 1.3.6.1.4.1.476.1.1.1.1.12.2.1 | RowlcUpsSwitchedReceptEntry | not-accessible | optional | |
| 1.3.6.1.4.1.476.1.1.1.1.12.2.1.1 | ColumnlcUpsSwitchedReceptIndex | read-only | optional | |
| 1.3.6.1.4.1.476.1.1.1.1.12.2.1.2 | ColumnlcUpsSwitchedReceptOnDelay | read-write | optional | Setting this object causes the agent to instruct the UPS to turn on a receptacle after the indicated number of seconds. The agent counts down the number of sec… |
| 1.3.6.1.4.1.476.1.1.1.1.12.2.1.3 | ColumnlcUpsSwitchedReceptOnTrapDelay | read-write | optional | When 'lcUpsSwitchedReceptOnDelay' reaches a value less than or equal to this object's value, an lcUpsReceptOnWarningTrap will be produced and this object will … |
| 1.3.6.1.4.1.476.1.1.1.1.12.2.1.4 | ColumnlcUpsSwitchedReceptOffDelay | read-write | optional | Setting this object causes the agent to instruct the UPS to turn off a receptacle after the indicated number of seconds. The agent counts down the number of se… |
| 1.3.6.1.4.1.476.1.1.1.1.12.2.1.5 | ColumnlcUpsSwitchedReceptOffTrapDelay | read-write | optional | When 'lcUpsSwitchedReceptOffDelay' reaches a value less than or equal to this object's value, an lcUpsReceptOffWarningTrap will be produced and this object wil… |
| 1.3.6.1.4.1.476.1.1.1.1.12.2.1.6 | ColumnlcUpsSwitchedReceptStatus | read-only | optional | The status of the device receptacle. Note that some devices may support Switched of device receptacles as a group only (by using lcUpsSwitchedOutputOffDelay an… |
| 1.3.6.1.4.1.476.1.1.1.1.12.2.1.7 | ColumnlcUpsSwitchedReceptLabel | read-write | optional | A user-defined text string associated with a switched receptacle. This may be used to describe the load powered from the receptacle. The text string is stored … |
| 1.3.6.1.4.1.476.1.1.1.2 | NodeluUPStationS | |||
| 1.3.6.1.4.1.476.1.1.1.2.1 | NodelsUpsIdent | |||
| 1.3.6.1.4.1.476.1.1.1.2.1.1 | ScalarlsUpsIdentFirmwareVersion | read-only | optional | The firmware revision level of the UPS. |
| 1.3.6.1.4.1.476.1.1.1.2.6 | NodelsUpsAlarm | |||
| 1.3.6.1.4.1.476.1.1.1.2.6.1 | NodelsUpsAlarmConditions | |||
| 1.3.6.1.4.1.476.1.1.1.2.6.1.1 | NodelsUpsAlarmCheckAirFilter | |||
| 1.3.6.1.4.1.476.1.1.1.2.11 | NodelsUpsTraps | |||
| 1.3.6.1.4.1.476.1.1.1.2.11.1 | NodelsUpsCheckAirFilterTrap | An lsUpsCheckAirFilterTrap signifies that the programmed time interval for checking the air filter has passed and it is time to check the air filter. | ||
| 1.3.6.1.4.1.476.1.1.1.2.12 | NodelsUpsConfig | |||
| 1.3.6.1.4.1.476.1.1.1.2.12.1 | ScalarlsUpsConfigBypassInstalled | read-only | optional | Indicates if a bypass is installed in the UPS. |
| 1.3.6.1.4.1.476.1.1.1.2.13 | NodelsUpsBypass | |||
| 1.3.6.1.4.1.476.1.1.1.2.13.1 | ScalarlsUpsOnBypass | read-only | optional | Indicates that the UPS is currently on bypass. |
| 1.3.6.1.4.1.476.1.1.1.2.13.2 | ScalarlsUpsBypassFrequency | read-only | optional | The current bypass frequency. (Unit of measure: Hertz) |
| 1.3.6.1.4.1.476.1.1.1.2.13.3 | ScalarlsUpsBypassNumLines | read-only | optional | The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. |
| 1.3.6.1.4.1.476.1.1.1.2.13.4 | TablelsUpsBypassTable | not-accessible | optional | |
| 1.3.6.1.4.1.476.1.1.1.2.13.4.1 | RowlsUpsBypassEntry | not-accessible | optional | |
| 1.3.6.1.4.1.476.1.1.1.2.13.4.1.1 | ColumnlsUpsBypassLine | read-only | optional | The bypass Line. |
| 1.3.6.1.4.1.476.1.1.1.2.13.4.1.2 | ColumnlsUpsBypassVoltage | read-only | optional | The bypass voltage. (Unit of measure: Volt) |
| 1.3.6.1.4.1.476.1.1.1.2.13.4.1.3 | ColumnlsUpsBypassCurrent | read-only | optional | The bypass current. (Unit of measure: Amp) |
| 1.3.6.1.4.1.476.1.1.1.7 | NodeluUPStationS3 | |||
| 1.3.6.1.4.1.476.1.1.2 | NodeluExperimental | |||
| 1.3.6.1.4.1.476.1.1.3 | NodeluPrivate |