MIB Viewer

LUM-EQUIPMENT-MIB

293 objects
The common equipment configuration MIB. - General - Subrack status - Board configuration and status - Power supply status - Fan status - Slot
Imported Objects
LUM-ALARM-MIB MISSINGAlarmPerceivedSeverity
LUM-REGlumEquipmentMIB lumModules
LUM-TC MISSINGAdminStatus BoardOrInterfaceAdminStatus BoardOrInterfaceOperStatus CommandString FaultStatus MgmtNameString ObjectProperty SlotNumber SubrackNumber TruthValueWithNA
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIInteger32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCDateAndTime DisplayString RowStatus TestAndIncr TEXTUAL-CONVENTION
OIDNameAccessStatusDescription
1.3.6.1.4.1.8708.1.1.12IdentitylumEquipmentMIBModuleThe common equipment configuration MIB. - General - Subrack status - Board configuration and status - Power supply status - Fan status - Slot
1.3.6.1.4.1.8708.2.11.1NodelumEquipmentConfs
1.3.6.1.4.1.8708.2.11.1.1NodelumEquipmentGroups
1.3.6.1.4.1.8708.2.11.1.1.1GroupequipmentGeneralGroupcurrentThe general objects.
1.3.6.1.4.1.8708.2.11.1.1.2GroupequipmentSubrackGroupdeprecatedThe subrack module objects.
1.3.6.1.4.1.8708.2.11.1.1.3GroupequipmentBoardGroupdeprecatedThe board objects.
1.3.6.1.4.1.8708.2.11.1.1.4GroupequipmentPowerGroupdeprecatedThe power module objects.
1.3.6.1.4.1.8708.2.11.1.1.5GroupequipmentFanGroupdeprecatedThe fan module objects.
1.3.6.1.4.1.8708.2.11.1.1.6GroupequipmentGeneralGroupV2deprecatedThe equipment general objects v2.
1.3.6.1.4.1.8708.2.11.1.1.7GroupequipmentNotificationGroupdeprecatedThe equipment notifications.
1.3.6.1.4.1.8708.2.11.1.1.8GroupequipmentSubrackGroupV2deprecatedThe subrack module objects V2.
1.3.6.1.4.1.8708.2.11.1.1.9GroupequipmentSubrackGroupV3deprecatedThe subrack module objects V3.
1.3.6.1.4.1.8708.2.11.1.1.10GroupequipmentBoardGroupV2deprecatedThe board objects V2.
1.3.6.1.4.1.8708.2.11.1.1.11GroupequipmentNodeGroupdeprecatedThe node objects.
1.3.6.1.4.1.8708.2.11.1.1.12GroupequipmentGeneralGroupV3deprecatedThe equipment general objects v3.
1.3.6.1.4.1.8708.2.11.1.1.13GroupequipmentNodeGroupV2deprecatedThe node objects.
1.3.6.1.4.1.8708.2.11.1.1.14GroupequipmentNodeGroupV3deprecatedThe node objects.
1.3.6.1.4.1.8708.2.11.1.1.15GroupequipmentSubrackGroupV4deprecatedThe subrack module objects V4.
1.3.6.1.4.1.8708.2.11.1.1.16GroupequipmentBoardGroupV3deprecatedThe board objects V3.
1.3.6.1.4.1.8708.2.11.1.1.17GroupequipmentNotificationGroupV2deprecatedThe equipment notifications.
1.3.6.1.4.1.8708.2.11.1.1.18GroupequipmentSubrackGroupV5deprecatedThe subrack module objects V5. (2.2)
1.3.6.1.4.1.8708.2.11.1.1.19GroupequipmentFanGroupV2deprecatedThe fan module objects.
1.3.6.1.4.1.8708.2.11.1.1.20GroupequipmentGeneralGroupV4deprecatedThe equipment general objects v4 (3.1).
1.3.6.1.4.1.8708.2.11.1.1.21GroupequipmentSubrackGroupV6deprecatedThe subrack module objects V6. (4.0)
1.3.6.1.4.1.8708.2.11.1.1.22GroupequipmentBoardGroupV4deprecatedThe board objects V4. (4.0)
1.3.6.1.4.1.8708.2.11.1.1.23GroupequipmentPowerGroupV2deprecatedThe power module objects (4.0).
1.3.6.1.4.1.8708.2.11.1.1.24GroupequipmentFanGroupV3deprecatedThe fan module objects (4.0).
1.3.6.1.4.1.8708.2.11.1.1.25GroupequipmentNodeGroupV4deprecatedThe node objects V4 (7.0)
1.3.6.1.4.1.8708.2.11.1.1.26GroupequipmentBoardGroupV5deprecatedThe board objects V5. (7.0)
1.3.6.1.4.1.8708.2.11.1.1.27GroupequipmentBoardGroupV6deprecatedThe board objects V6. (8.0)
1.3.6.1.4.1.8708.2.11.1.1.28GroupequipmentBoardGroupV7deprecatedThe board objects V7. (9.0)
1.3.6.1.4.1.8708.2.11.1.1.29GroupequipmentNodeGroupV8deprecatedThe node objects V8 (11.0)
1.3.6.1.4.1.8708.2.11.1.1.30GroupequipmentBoardGroupV8deprecatedThe board objects V8. (12.0)
1.3.6.1.4.1.8708.2.11.1.1.31GroupequipmentNodeGroupV9deprecatedThe node objects V9 (14.0)
1.3.6.1.4.1.8708.2.11.1.1.32GroupequipmentResourceGroupcurrentThe resouce objects V1 (16.0)
1.3.6.1.4.1.8708.2.11.1.1.33GroupequipmentSubrackGroupV7deprecatedThe subrack module objects V7. (16.0)
1.3.6.1.4.1.8708.2.11.1.1.34GroupequipmentSubrackGroupV8deprecatedThe subrack module objects V8. (17.0)
1.3.6.1.4.1.8708.2.11.1.1.35GroupequipmentBoardGroupV9deprecatedThe board objects V9. (17.0)
1.3.6.1.4.1.8708.2.11.1.1.36GroupequipmentNotificationGroupV3currentThe equipment notifications.
1.3.6.1.4.1.8708.2.11.1.1.37GroupequipmentBoardGroupV10deprecatedThe board objects V10. (17.0)
1.3.6.1.4.1.8708.2.11.1.1.38GroupequipmentNodeGroupV10deprecatedThe node objects V10 (18.0)
1.3.6.1.4.1.8708.2.11.1.1.40GroupequipmentBoardGroupV11deprecatedThe board objects V11. (20.0)
1.3.6.1.4.1.8708.2.11.1.1.41GroupequipmentFanGroupV4deprecatedThe fan module objects V4. (20.0)
1.3.6.1.4.1.8708.2.11.1.1.42GroupequipmentSlotGroupdeprecatedThe slot module objects. (20.0)
1.3.6.1.4.1.8708.2.11.1.1.43GroupequipmentBoardGroupV12deprecatedThe board objects V12. (21.0)
1.3.6.1.4.1.8708.2.11.1.1.44GroupequipmentNodeGroupV11currentThe node objects V11 (21.0)
1.3.6.1.4.1.8708.2.11.1.1.45GroupequipmentBoardGroupV13deprecatedThe board objects V13. (27.0)
1.3.6.1.4.1.8708.2.11.1.1.46GroupequipmentPowerGroupV3deprecatedThe power module objects V3 (27.0).
1.3.6.1.4.1.8708.2.11.1.1.47GroupequipmentBoardGroupV14currentThe board objects V14. (28.0)
1.3.6.1.4.1.8708.2.11.1.1.48GroupequipmentSlotGroupV2currentThe slot module objects V2. (28.0)
1.3.6.1.4.1.8708.2.11.1.1.49GroupequipmentSubrackGroupV9deprecatedThe subrack module objects V9. (28.0)
1.3.6.1.4.1.8708.2.11.1.1.50GroupequipmentPowerGroupV4deprecatedThe power module objects V4 (28.0).
1.3.6.1.4.1.8708.2.11.1.1.51GroupequipmentFanGroupV5currentThe fan module objects V5. (28.0)
1.3.6.1.4.1.8708.2.11.1.1.52GroupequipmentGeneralGroupV5deprecatedThe equipment general objects v5 (R28.0).
1.3.6.1.4.1.8708.2.11.1.1.53GroupequipmentSubrackGroupV10currentThe subrack module objects V10. (29.0)
1.3.6.1.4.1.8708.2.11.1.1.54GroupequipmentGeneralGroupV6currentThe equipment general objects v6 (R31.0).
1.3.6.1.4.1.8708.2.11.1.1.55GroupequipmentOpticalModuleGroupcurrentThe equipment optical module objects v6 (R31.0).
1.3.6.1.4.1.8708.2.11.1.1.56GroupequipmentPowerGroupV5currentThe power module objects V5 (32.1).
1.3.6.1.4.1.8708.2.11.1.2NodelumEquipmentCompl
1.3.6.1.4.1.8708.2.11.1.2.1CompliancelumEquipmentBasicComplV1deprecatedBasic implementation requirements for the equipment MIB.
1.3.6.1.4.1.8708.2.11.1.2.2CompliancelumEquipmentBasicComplV2deprecatedBasic implementation requirements for the equipment MIB V2.
1.3.6.1.4.1.8708.2.11.1.2.3CompliancelumEquipmentBasicComplV3deprecatedBasic implementation requirements for the equipment MIB V3.
1.3.6.1.4.1.8708.2.11.1.2.4CompliancelumEquipmentBasicComplV4deprecatedBasic implementation requirements for the equipment MIB V4.
1.3.6.1.4.1.8708.2.11.1.2.5CompliancelumEquipmentBasicComplV5deprecatedBasic implementation requirements for the equipment MIB V5.
1.3.6.1.4.1.8708.2.11.1.2.6CompliancelumEquipmentBasicComplV6deprecatedBasic implementation requirements for the equipment MIB V6.
1.3.6.1.4.1.8708.2.11.1.2.7CompliancelumEquipmentBasicComplV7deprecatedBasic implementation requirements for the equipment MIB V7.
1.3.6.1.4.1.8708.2.11.1.2.8CompliancelumEquipmentBasicComplV8deprecatedBasic implementation requirements for the equipment MIB V8.
1.3.6.1.4.1.8708.2.11.1.2.9CompliancelumEquipmentBasicComplV9deprecatedBasic implementation requirements for the equipment MIB V9.
1.3.6.1.4.1.8708.2.11.1.2.10CompliancelumEquipmentBasicComplV10deprecatedBasic implementation requirements for the equipment MIB V10.
1.3.6.1.4.1.8708.2.11.1.2.11CompliancelumEquipmentBasicComplV11deprecatedBasic implementation requirements for the equipment MIB V11. Equivalent to V10, but the notifications differ...
1.3.6.1.4.1.8708.2.11.1.2.12CompliancelumEquipmentBasicComplV12deprecatedBasic implementation requirements for the equipment MIB V12.
1.3.6.1.4.1.8708.2.11.1.2.13CompliancelumEquipmentBasicComplV13deprecatedBasic implementation requirements for the equipment MIB V13. (2.2)
1.3.6.1.4.1.8708.2.11.1.2.14CompliancelumEquipmentBasicComplV14deprecatedBasic implementation requirements for the equipment MIB V14. (2.3)
1.3.6.1.4.1.8708.2.11.1.2.15CompliancelumEquipmentBasicComplV15deprecatedBasic implementation requirements for the equipment MIB V15. (2.3.2)
1.3.6.1.4.1.8708.2.11.1.2.16CompliancelumEquipmentBasicComplV16deprecatedBasic implementation requirements for the equipment MIB V16. (3.0)
1.3.6.1.4.1.8708.2.11.1.2.17CompliancelumEquipmentBasicComplV17deprecatedBasic implementation requirements for the equipment MIB V17. (3.1)
1.3.6.1.4.1.8708.2.11.1.2.18CompliancelumEquipmentBasicComplV18deprecatedBasic implementation requirements for the equipment MIB V18. (4.0)
1.3.6.1.4.1.8708.2.11.1.2.19CompliancelumEquipmentBasicComplV19deprecatedBasic implementation requirements for the equipment MIB V19. (7.0)
1.3.6.1.4.1.8708.2.11.1.2.20CompliancelumEquipmentBasicComplV20deprecatedBasic implementation requirements for the equipment MIB V20. (8.0)
1.3.6.1.4.1.8708.2.11.1.2.21CompliancelumEquipmentBasicComplV21deprecatedBasic implementation requirements for the equipment MIB V21. (9.0)
1.3.6.1.4.1.8708.2.11.1.2.22CompliancelumEquipmentBasicComplV22deprecatedBasic implementation requirements for the equipment MIB V22. (10.0)
1.3.6.1.4.1.8708.2.11.1.2.23CompliancelumEquipmentBasicComplV23deprecatedBasic implementation requirements for the equipment MIB V23. (11.0)
1.3.6.1.4.1.8708.2.11.1.2.24CompliancelumEquipmentBasicComplV24deprecatedBasic implementation requirements for the equipment MIB V24. (12.0)
1.3.6.1.4.1.8708.2.11.1.2.25CompliancelumEquipmentBasicComplV25deprecatedBasic implementation requirements for the equipment MIB V24. (14.0)
1.3.6.1.4.1.8708.2.11.1.2.26CompliancelumEquipmentBasicComplV26deprecatedBasic implementation requirements for the equipment MIB V26. (16.0)
1.3.6.1.4.1.8708.2.11.1.2.27CompliancelumEquipmentBasicComplV27deprecatedBasic implementation requirements for the equipment MIB V26. (16.0)
1.3.6.1.4.1.8708.2.11.1.2.28CompliancelumEquipmentBasicComplV28deprecatedBasic implementation requirements for the equipment MIB V28. (17.0)
1.3.6.1.4.1.8708.2.11.1.2.29CompliancelumEquipmentBasicComplV29deprecatedBasic implementation requirements for the equipment MIB V28. (17.0)
1.3.6.1.4.1.8708.2.11.1.2.30CompliancelumEquipmentBasicComplV30deprecatedBasic implementation requirements for the equipment MIB V30. (18.0)
1.3.6.1.4.1.8708.2.11.1.2.31CompliancelumEquipmentBasicComplV31deprecatedBasic implementation requirements for the equipment MIB V31. (20.0)
1.3.6.1.4.1.8708.2.11.1.2.32CompliancelumEquipmentBasicComplV32deprecatedBasic implementation requirements for the equipment MIB V32. (21.0)
1.3.6.1.4.1.8708.2.11.1.2.33CompliancelumEquipmentBasicComplV33deprecatedBasic implementation requirements for the equipment MIB V33. (27.0)
1.3.6.1.4.1.8708.2.11.1.2.34CompliancelumEquipmentBasicComplV34deprecatedBasic implementation requirements for the equipment MIB V34. (28.0)
1.3.6.1.4.1.8708.2.11.1.2.35CompliancelumEquipmentBasicComplV35deprecatedBasic implementation requirements for the equipment MIB V35. (29.0)
1.3.6.1.4.1.8708.2.11.1.2.36CompliancelumEquipmentBasicComplV36deprecatedBasic implementation requirements for the equipment MIB V36. (31.0)
1.3.6.1.4.1.8708.2.11.1.2.37CompliancelumEquipmentBasicComplV37currentBasic implementation requirements for the equipment MIB V37. (32.1)
1.3.6.1.4.1.8708.2.11.1.3NodelumEquipmentMinimalGroups
1.3.6.1.4.1.8708.2.11.1.3.1GroupequipmentGeneralMinimalGroupV1currentThe minimal general equipment MIB objects.
1.3.6.1.4.1.8708.2.11.1.3.2GroupequipmentBoardMinimalGroupV1deprecatedThe minimal board objects.
1.3.6.1.4.1.8708.2.11.1.3.3GroupequipmentBoardMinimalGroupV2currentThe minimal board objects.
1.3.6.1.4.1.8708.2.11.1.4NodelumEquipmentMinimalCompl
1.3.6.1.4.1.8708.2.11.1.4.1CompliancelumEquipmentMinimalComplV1deprecatedMinimal implementation requirements for the equipment MIB V1.
1.3.6.1.4.1.8708.2.11.1.4.2CompliancelumEquipmentMinimalComplV2deprecatedMinimal implementation requirements for the equipment MIB V2.
1.3.6.1.4.1.8708.2.11.1.4.3CompliancelumEquipmentMinimalComplV3deprecatedMinimal implementation requirements for the equipment MIB V3.
1.3.6.1.4.1.8708.2.11.1.4.4CompliancelumEquipmentMinimalComplV4currentMinimal implementation requirements for the equipment MIB V4.
1.3.6.1.4.1.8708.2.11.1.4.5CompliancelumEquipmentMinimalComplV5deprecatedMinimal implementation requirements for the equipment MIB V5.
1.3.6.1.4.1.8708.2.11.1.4.6CompliancelumEquipmentMinimalComplV6currentMinimal implementation requirements for the equipment MIB V6.
1.3.6.1.4.1.8708.2.11.2NodelumEquipmentMIBObjects
1.3.6.1.4.1.8708.2.11.2.1NodeequipmentGeneral
1.3.6.1.4.1.8708.2.11.2.1.1ScalarequipmentGeneralTestAndIncrread-writecurrentProtection against simultaneous access from multiple managers. See SNMPv2-TC.
1.3.6.1.4.1.8708.2.11.2.1.2ScalarequipmentGeneralMibSpecVersionread-writecurrentThe MIB specification version. tbd: persistent?
1.3.6.1.4.1.8708.2.11.2.1.3ScalarequipmentGeneralMibImplVersionread-writecurrentThe MIB implementation version.
1.3.6.1.4.1.8708.2.11.2.1.4ScalarequipmentGeneralLastChangeTimeread-onlycurrentThe time when the configuration of the MIB was last changed.
1.3.6.1.4.1.8708.2.11.2.1.5ScalarequipmentGeneralStateLastChangeTimeread-onlycurrentThe time when the state of the MIB was last changed.
1.3.6.1.4.1.8708.2.11.2.1.6ScalarequipmentGeneralEquipmentSubrackTableSizeread-onlycurrentSize of table
1.3.6.1.4.1.8708.2.11.2.1.7ScalarequipmentGeneralEquipmentBoardTableSizeread-onlycurrentSize of table
1.3.6.1.4.1.8708.2.11.2.1.8ScalarequipmentGeneralEquipmentPowerTableSizeread-onlycurrentSize of table
1.3.6.1.4.1.8708.2.11.2.1.9ScalarequipmentGeneralEquipmentFanTableSizeread-onlycurrentSize of table
1.3.6.1.4.1.8708.2.11.2.1.10ScalarequipmentGeneralEquipmentSlotTableSizeread-onlycurrentSize of table
1.3.6.1.4.1.8708.2.11.2.1.11ScalarequipmentGeneralEquipmentOpticalModuleTableSizeread-onlycurrentSize of table
1.3.6.1.4.1.8708.2.11.2.2NodeequipmentSubrackList
1.3.6.1.4.1.8708.2.11.2.2.1TableequipmentSubrackTablenot-accessiblecurrentThe subrack list.
1.3.6.1.4.1.8708.2.11.2.2.1.1RowequipmentSubrackEntrynot-accessiblecurrentAn entry in the subrack list.
1.3.6.1.4.1.8708.2.11.2.2.1.1.1ColumnequipmentSubrackIndexread-onlycurrentAn arbitrary index assigned to each subrack entry.
1.3.6.1.4.1.8708.2.11.2.2.1.1.2ColumnequipmentSubrackNameread-onlycurrentThe name of the subrack, for example 'sub1' where the number indicates the subrack number.
1.3.6.1.4.1.8708.2.11.2.2.1.1.3ColumnequipmentSubrackSubrackread-createcurrentThe number of the subrack.
1.3.6.1.4.1.8708.2.11.2.2.1.1.4ColumnequipmentSubrackDescrread-writecurrentUser configurable label.
1.3.6.1.4.1.8708.2.11.2.2.1.1.5ColumnequipmentSubrackInvPhysIndexOrZeroread-onlycurrentThe row in the invPhysTable for this subrack. Set to 0 if not known.
1.3.6.1.4.1.8708.2.11.2.2.1.1.6ColumnequipmentSubrackAllFanUnitsFailedread-onlycurrentAll fan units in a subrack have failed. A(ctivation): fanUnitFailed active for all fans within a subrack. D(e-activiation): fanUnitFailed cleared for one fan u…
1.3.6.1.4.1.8708.2.11.2.2.1.1.7ColumnequipmentSubrackRowStatusread-createcurrentSNMP administrivia. Manages creation and deletion of conceptual rows. See also SNMPv2-TC.
1.3.6.1.4.1.8708.2.11.2.2.1.1.8ColumnequipmentSubrackExpectedTyperead-writecurrentThe expected subrack type.
1.3.6.1.4.1.8708.2.11.2.2.1.1.9ColumnequipmentSubrackActualTyperead-onlycurrentThe actual subrack type. If an unexpected subrack has been detected this variable can be used to see what type of subrack has been detected.
1.3.6.1.4.1.8708.2.11.2.2.1.1.10ColumnequipmentSubrackUnexpectedTyperead-onlycurrentA type of subrack not matching the expected type is present. A: A subrack with type different from the expected type is present (even if the subrack is not act…
1.3.6.1.4.1.8708.2.11.2.2.1.1.11ColumnequipmentSubrackTempread-onlycurrentThe temperature in the subrack in 0.1 degrees centigrade.
1.3.6.1.4.1.8708.2.11.2.2.1.1.12ColumnequipmentSubrackTempHighExceededread-onlycurrentThe threshold for environmental temperature in the subrack is exceeded. A: The temperature exceeds the associated threshold. D: Temperature is 0.5 degrees cent…
1.3.6.1.4.1.8708.2.11.2.2.1.1.13ColumnequipmentSubrackTempThresholdread-writecurrentThe threshold for temperature alarm in the subrack in 0.1 degrees centigrade.
1.3.6.1.4.1.8708.2.11.2.2.1.1.14ColumnequipmentSubrackDataChangedread-onlycurrentThe subrack data (dipswitches for subrackId and/or system mode) has been changed. Changing this data might affect the system behaviour after the next restart. …
1.3.6.1.4.1.8708.2.11.2.2.1.1.15ColumnequipmentSubrackSystemModeSetread-onlycurrentThe value read from the system mode dipswitches at startup of the CU was diffrent from 0. This will affect the behaviour of the system. If the lowest bit is se…
1.3.6.1.4.1.8708.2.11.2.2.1.1.16ColumnequipmentSubrackEffectiveSystemModeread-onlycurrentThe value of the system mode dipswitches read at startup. This value determines the system behaviour.
1.3.6.1.4.1.8708.2.11.2.2.1.1.17ColumnequipmentSubrackCurrentSystemModeread-onlycurrentThe current value of the system mode dipswitches. Will be used at the next restart.
1.3.6.1.4.1.8708.2.11.2.2.1.1.18ColumnequipmentSubrackAdminStatusread-writecurrentThe administrative state of the subrack. down - This subrack should not be monitored. Suppresses alarms. up - The subrack should be monitored.
1.3.6.1.4.1.8708.2.11.2.2.1.1.19ColumnequipmentSubrackOperStatusread-onlycurrentThe operational state of the subrack. notPresent - The subrack is not available. down - The subrack remains in the 'down'-state when adminStatus is set to 'dow…
1.3.6.1.4.1.8708.2.11.2.2.1.1.20ColumnequipmentSubrackObjectPropertyread-onlycurrentProperty mask.
1.3.6.1.4.1.8708.2.11.2.2.1.1.21ColumnequipmentSubrackShelfLengthread-writecurrentLength of the half-height slot divider shelf. To be manually entered by the user. A value of 0 is interpreted as 'not yet defined by user'.
1.3.6.1.4.1.8708.2.11.2.2.1.1.22ColumnequipmentSubrackLANModuleMissingread-onlycurrentThe subrack LAN/DCN module is missing. A(ctivation): LAN/DCN module disconnected from subrack for more than 2 seconds. D(e-activiation): LAN/DCN module connect…
1.3.6.1.4.1.8708.2.11.2.2.1.1.23ColumnequipmentSubrackExpectedFirstPbSlotread-writecurrentThe lowest slot number where it is possible to configure a passive board. Automatically configured to the actual value supported by hardware if the hardware is…
1.3.6.1.4.1.8708.2.11.2.2.1.1.24ColumnequipmentSubrackActualFirstPbSlotread-onlycurrentThe actual lowest slot number where it is possible to configure a passive board. When no subrack hardware is present, this value is 'undefined'.
1.3.6.1.4.1.8708.2.11.2.2.1.1.25ColumnequipmentSubrackFirstPbSlotMismatchread-onlycurrentThe expected first passive slot allows more passive boards than the hardware supports. A(ctivation): A subrack and control unit combination which supports fewe…
1.3.6.1.4.1.8708.2.11.2.2.1.1.26ColumnequipmentSubrackAidread-onlycurrentThe access identifier (AID) of the product. The format is according to GR-833.
1.3.6.1.4.1.8708.2.11.2.2.1.1.27ColumnequipmentSubrackPhysicalLocationread-onlycurrentThe Physical location of the product. The format is according to GR-833.
1.3.6.1.4.1.8708.2.11.2.2.1.1.28ColumnequipmentSubrackChangeExpectedTyperead-onlycurrentCommand to change expected type, used when upgrading subrack to a new version, e.g TM3000 to TM3000/II
1.3.6.1.4.1.8708.2.11.2.3NodeequipmentBoardList
1.3.6.1.4.1.8708.2.11.2.3.1TableequipmentBoardTablenot-accessiblecurrentThe board list.
1.3.6.1.4.1.8708.2.11.2.3.1.1RowequipmentBoardEntrynot-accessiblecurrentAn entry in the board list. One entry for each slot.
1.3.6.1.4.1.8708.2.11.2.3.1.1.1ColumnequipmentBoardIndexread-onlycurrentAn arbitrary index assigned to each board entry.
1.3.6.1.4.1.8708.2.11.2.3.1.1.2ColumnequipmentBoardNameread-onlycurrentThe name of the board, for example 'tpmr2500:1:2' where the first number indicates in which sub-rack the board is present and the second number in which slot.
1.3.6.1.4.1.8708.2.11.2.3.1.1.3ColumnequipmentBoardExpectedTyperead-createcurrentThe expected board type.
1.3.6.1.4.1.8708.2.11.2.3.1.1.4ColumnequipmentBoardActualTyperead-onlycurrentThe actual board type. If an unexpected board has been detected this variable can be used to see what type of board has been detected.
1.3.6.1.4.1.8708.2.11.2.3.1.1.5ColumnequipmentBoardDescrread-writecurrentUser configurable label.
1.3.6.1.4.1.8708.2.11.2.3.1.1.6ColumnequipmentBoardSubrackread-createcurrentThe number of the subrack where the board is located.
1.3.6.1.4.1.8708.2.11.2.3.1.1.7ColumnequipmentBoardSlotread-createcurrentThe slot where the board is located.
1.3.6.1.4.1.8708.2.11.2.3.1.1.8ColumnequipmentBoardTempread-onlycurrentThe temperature on the board in 0.1 degrees centigrade.
1.3.6.1.4.1.8708.2.11.2.3.1.1.9ColumnequipmentBoardInvPhysIndexOrZeroread-onlycurrentThe row in the invPhysTable for this board. Set to 0 if not known.
1.3.6.1.4.1.8708.2.11.2.3.1.1.10ColumnequipmentBoardLedTestread-writecurrentLED test for the board. off - Normal operation. on - Light all leds.
1.3.6.1.4.1.8708.2.11.2.3.1.1.11ColumnequipmentBoardAdminStatusread-writecurrentThe administrative state of the board. down - The board should be inactive. Alarms are suppressed. service - The board is activated but alarms are suppressed. …
1.3.6.1.4.1.8708.2.11.2.3.1.1.12ColumnequipmentBoardOperStatusread-onlycurrentThe operational state of the board. notPresent - The board is not available. down - The board remains in the 'down'-state when adminStatus is set to 'down' or …
1.3.6.1.4.1.8708.2.11.2.3.1.1.13ColumnequipmentBoardLastChangeTimeread-onlycurrentThe time when the operational state of the board entry was last changed.
1.3.6.1.4.1.8708.2.11.2.3.1.1.14ColumnequipmentBoardRowStatusread-createcurrentSNMP administrivia. Manages creation and deletion of conceptual rows. See also SNMPv2-TC.
1.3.6.1.4.1.8708.2.11.2.3.1.1.15ColumnequipmentBoardMissingread-onlycurrentThere is no board present in a slot where the expected board type is defined. Suppressed if administrative status is down. A(ctivation): Card out of place (COP…
1.3.6.1.4.1.8708.2.11.2.3.1.1.16ColumnequipmentBoardUnexpectedTyperead-onlycurrentA type of board not matching the expected type is present and active in the same slot. Since the default value for the type is 'undefined' this alarm is raised…
1.3.6.1.4.1.8708.2.11.2.3.1.1.17ColumnequipmentBoardTempHighExceededread-onlycurrentThe threshold for environmental temperature on the board is exceeded. A: The temperature exceeds the associated threshold. D: Temperature is 0.5 degrees centig…
1.3.6.1.4.1.8708.2.11.2.3.1.1.18ColumnequipmentBoardCommunicationFailureread-onlycurrentCommunication between the control unit and the the board has failed completely. A: There is a board present but there has been no communication established wit…
1.3.6.1.4.1.8708.2.11.2.3.1.1.19ColumnequipmentBoardInterworkFailedread-onlycurrentCommunication between the control unit and the board has failed due to incompatible software. A: The control unit and the board have in-compatible software. D:…
1.3.6.1.4.1.8708.2.11.2.3.1.1.20ColumnequipmentBoardSecondaryPowerFailedread-onlycurrentSecondary DC power (1.8 or 2.5 V) failure. A: The secondary DC power on the board has failed. D: The secondary DC power is present. Note: If primary power fail…
1.3.6.1.4.1.8708.2.11.2.3.1.1.21ColumnequipmentBoardVitalDataMissingread-onlycurrentProduct data vital for the safe operation of the equipment is missing. A: Product data missing. D: Product data present.
1.3.6.1.4.1.8708.2.11.2.3.1.1.22ColumnequipmentBoardNonVitalDataMissingread-onlycurrentAdministrative product data is missing. A: Product data missing. D: Product data present.
1.3.6.1.4.1.8708.2.11.2.3.1.1.23ColumnequipmentBoardUnderMaintenanceread-onlycurrentThe board is undergoing maintenance, adminStatus is set to service. A: AdminStatus is set to service. D: AdminStatus is set to another value.
1.3.6.1.4.1.8708.2.11.2.3.1.1.24ColumnequipmentBoardTempThresholdread-writecurrentThe threshold for temperature alarm on the board in 0.1 degrees centigrade.
1.3.6.1.4.1.8708.2.11.2.3.1.1.25ColumnequipmentBoardSwVersionMismatchread-onlycurrentThe version of the board SW does not match the SW version running och the main CU. For versions to match, the release number, e.g. 'r2b', must be the same. The…
1.3.6.1.4.1.8708.2.11.2.3.1.1.26ColumnequipmentBoardObjectPropertyread-onlycurrentProperty mask.
1.3.6.1.4.1.8708.2.11.2.3.1.1.27ColumnequipmentBoardTempLowread-onlycurrentThe low threshold for environmental temperature on the board is exceeded. A: The temperature exceeds the associated low threshold. D: Temperature is 0.5 degree…
1.3.6.1.4.1.8708.2.11.2.3.1.1.28ColumnequipmentBoardTempVeryHighread-onlycurrentThe very high threshold for environmental temperature on the board is exceeded. A: The temperature exceeds the associated threshold. D: Temperature is 0.5 degr…
1.3.6.1.4.1.8708.2.11.2.3.1.1.29ColumnequipmentBoardReconfigureread-onlycurrentApplicable for cu, cu2osc, cuSfp, cuSfpii and voa8chii. Reconfigure cu or cu2osc board to cuSfp. Reconfigure cu2osc or cuSfp board to cuSfpii. Reconfigure olde…
1.3.6.1.4.1.8708.2.11.2.3.1.1.30ColumnequipmentBoardLedStatusread-onlycurrentLED status for the board. This is primarily intended for debugging
1.3.6.1.4.1.8708.2.11.2.3.1.1.31ColumnequipmentBoardModuleInforead-onlycurrentInformation (for example firmware and serial number) about the module.
1.3.6.1.4.1.8708.2.11.2.3.1.1.32ColumnequipmentBoardNewSwActivatedButNotRestartedread-onlycurrentA new SW version on the board has been activated, but the board has not been rebooted. This means that after the next reboot, a new SW will be active. For the …
1.3.6.1.4.1.8708.2.11.2.3.1.1.33ColumnequipmentBoardLowTemperatureread-onlycurrentThe environmental temperature on the board is below startuptemperature (+3 centigrade). A: The temperature is below +3 degrees centigrade. D: Temperature has i…
1.3.6.1.4.1.8708.2.11.2.3.1.1.34ColumnequipmentBoardTempLowThresholdread-onlycurrentThe threshold for low temperature alarm on the board in 0.1 degrees centigrade.
1.3.6.1.4.1.8708.2.11.2.3.1.1.35ColumnequipmentBoardAdditionalInforead-onlycurrentAdditional information about the board, e.g. FPGA revision.
1.3.6.1.4.1.8708.2.11.2.3.1.1.36ColumnequipmentBoardBootErrorread-onlycurrentThe card fails to boot. A: The card fails to boot. D: The card boot successfully.
1.3.6.1.4.1.8708.2.11.2.3.1.1.37ColumnequipmentBoardHardwareErrorread-onlycurrentA hardware error occured. A: A hardware error occured. D: No hardware error.
1.3.6.1.4.1.8708.2.11.2.3.1.1.38ColumnequipmentBoardLowDiskSpaceread-onlycurrentLow disk space in the board. A: Not enough disk space. D: Disk space is enough.
1.3.6.1.4.1.8708.2.11.2.3.1.1.39ColumnequipmentBoardClockDriftread-onlycurrentClock frequency is out of range. A: Clock frequency out is out of range. D: Clock frequency is in range.
1.3.6.1.4.1.8708.2.11.2.3.1.1.40ColumnequipmentBoardPostponeFwUpgraderead-writecurrentPostpone activation of new traffic firmware when the board software is upgraded next time. If no firmware changes are available when upgrading this option will…
1.3.6.1.4.1.8708.2.11.2.3.1.1.41ColumnequipmentBoardActivatePendingFwCommandread-onlycurrentCommand to activate a pending firmware upgrade.
1.3.6.1.4.1.8708.2.11.2.3.1.1.42ColumnequipmentBoardFwActivationPendingread-onlycurrentFirmware activation has been postponed in a previous software upgrade.
1.3.6.1.4.1.8708.2.11.2.3.1.1.43ColumnequipmentBoardFeatureNotSupportedread-onlycurrentA configuration request has failed since the chosen feature is not supported by the active firmware.
1.3.6.1.4.1.8708.2.11.2.3.1.1.44ColumnequipmentBoardFwReloadNeededread-onlycurrentThe traffic HW has been programmed by a version of the system that does not offer a supported upgrade path to the currently running version. This typically hap…
1.3.6.1.4.1.8708.2.11.2.3.1.1.45ColumnequipmentBoardFwContextUnknownread-onlycurrentThe running version of the SW cannot recover the settings of the traffic HW/FW. The state of the traffic HW is unknown. A reset of the traffic unit is recommen…
1.3.6.1.4.1.8708.2.11.2.3.1.1.46ColumnequipmentBoardBoardVariantread-writecurrentDetermines board configuration. dualMuxponderProt - 2x Muxponder with protection hexTransponder - 6x Transponder tripleMuxponderProt - 3x Muxponder with protec…
1.3.6.1.4.1.8708.2.11.2.3.1.1.47ColumnequipmentBoardCabinetConnectivityread-writecurrentMonitor Cabinet status if enabled. Alarm is raised if connection is lost.
1.3.6.1.4.1.8708.2.11.2.3.1.1.48ColumnequipmentBoardCabinetConnectionFailureread-onlycurrentConnection to the cabinet has failed.
1.3.6.1.4.1.8708.2.11.2.3.1.1.49ColumnequipmentBoardOperationalVariantread-createcurrentOperational Variant mode of board, Normal or OpenFlow Controlled.
1.3.6.1.4.1.8708.2.11.2.3.1.1.50ColumnequipmentBoardAidread-onlycurrentThe access identifier (AID) of the product. The format is according to GR-833.
1.3.6.1.4.1.8708.2.11.2.3.1.1.51ColumnequipmentBoardPhysicalLocationread-onlycurrentThe Physical location of the product. The format is according to GR-833.
1.3.6.1.4.1.8708.2.11.2.4NodeequipmentPowerList
1.3.6.1.4.1.8708.2.11.2.4.1TableequipmentPowerTablenot-accessiblecurrentThe list of power supplies.
1.3.6.1.4.1.8708.2.11.2.4.1.1RowequipmentPowerEntrynot-accessiblecurrentAn entry in the power supply list.
1.3.6.1.4.1.8708.2.11.2.4.1.1.1ColumnequipmentPowerIndexread-onlycurrentAn arbitrary index assigned to each power module.
1.3.6.1.4.1.8708.2.11.2.4.1.1.2ColumnequipmentPowerNameread-onlycurrentThe name of the power module. For example 'pow:1:2'.
1.3.6.1.4.1.8708.2.11.2.4.1.1.3ColumnequipmentPowerSubrackread-onlycurrentThe number of the subrack in which the power module is present.
1.3.6.1.4.1.8708.2.11.2.4.1.1.4ColumnequipmentPowerSlotread-onlycurrentThe number of the slot in which the power module is present.
1.3.6.1.4.1.8708.2.11.2.4.1.1.5ColumnequipmentPowerTyperead-onlycurrentThe the type of power module. ac - AC power supply (230V). dc - DC power supply (48V).
1.3.6.1.4.1.8708.2.11.2.4.1.1.9ColumnequipmentPowerInvPhysIndexOrZeroread-onlycurrentThe row in the invPhysTable for this power module. Set to 0 if not known.
1.3.6.1.4.1.8708.2.11.2.4.1.1.10ColumnequipmentPowerAdminStatusread-writecurrentThe administrative state of the power module. down - This power module is not monitored. Suppresses alarms. up - The power module is monitored.
1.3.6.1.4.1.8708.2.11.2.4.1.1.11ColumnequipmentPowerOperStatusread-onlycurrentThe operational state of the power module. notPresent - The power module is not present. down - The module is not active or there are faults preventing it from…
1.3.6.1.4.1.8708.2.11.2.4.1.1.12ColumnequipmentPowerRowStatusread-writecurrentManages creation and deletion of conceptual rows. See also SNMPv2-TC.
1.3.6.1.4.1.8708.2.11.2.4.1.1.13ColumnequipmentPowerACPowerFailedread-onlyobsoleteAC power supply failed (230 V). A(ctivation): Active HW indication. D(e-activation): Inactive HW indication.
1.3.6.1.4.1.8708.2.11.2.4.1.1.14ColumnequipmentPowerDCPowerFailedread-onlyobsoleteDC power supply failed (48 V). A: Active HW indication. D: Inactive HW indication.
1.3.6.1.4.1.8708.2.11.2.4.1.1.15ColumnequipmentPowerTemperatureHighread-onlycurrentThe built-in temperature monitoring of the power module thinks it is too hot. A: Active HW indication. D: Inactive HW indication.
1.3.6.1.4.1.8708.2.11.2.4.1.1.16ColumnequipmentPowerModuleMissingread-onlycurrentThe power module is not available. A: Active HW indication. D: Inactive HW indication.
1.3.6.1.4.1.8708.2.11.2.4.1.1.17ColumnequipmentPowerObjectPropertyread-onlycurrentProperty mask.
1.3.6.1.4.1.8708.2.11.2.4.1.1.18ColumnequipmentPowerDCPowerFailedSeverityread-writecurrentThe severity of DC Power failed alarm.
1.3.6.1.4.1.8708.2.11.2.4.1.1.19ColumnequipmentPowerAidread-onlycurrentThe access identifier (AID) of the product. The format is according to GR-833.
1.3.6.1.4.1.8708.2.11.2.4.1.1.20ColumnequipmentPowerPhysicalLocationread-onlycurrentThe Physical location of the product. The format is according to GR-833.
1.3.6.1.4.1.8708.2.11.2.4.1.1.21ColumnequipmentPowerPowerFailedread-onlycurrentPower supply failed. A: Active HW indication. D: Inactive HW indication.
1.3.6.1.4.1.8708.2.11.2.5NodeequipmentFanList
1.3.6.1.4.1.8708.2.11.2.5.1TableequipmentFanTablenot-accessiblecurrentThe list of fan modules.
1.3.6.1.4.1.8708.2.11.2.5.1.1RowequipmentFanEntrynot-accessiblecurrentAn entry in the fan module list.
1.3.6.1.4.1.8708.2.11.2.5.1.1.1ColumnequipmentFanIndexread-onlycurrentAn arbitrary index assigned to each fan module.
1.3.6.1.4.1.8708.2.11.2.5.1.1.2ColumnequipmentFanNameread-onlycurrentThe name of the fan module. For example 'fan:1:2', where the first number indicates the subrack and the second number the fan slot.
1.3.6.1.4.1.8708.2.11.2.5.1.1.3ColumnequipmentFanSubrackread-onlycurrentThe number of the subrack in which the fan module is present.
1.3.6.1.4.1.8708.2.11.2.5.1.1.4ColumnequipmentFanSlotread-onlycurrentThe number of the fan-slot in which the fan module is present.
1.3.6.1.4.1.8708.2.11.2.5.1.1.5ColumnequipmentFanInvPhysIndexOrZeroread-onlycurrentThe row in the invPhysTable for this fan module. Set to 0 if not known.
1.3.6.1.4.1.8708.2.11.2.5.1.1.6ColumnequipmentFanAdminStatusread-writecurrentThe administrative state of the fan module. down - This fan module should not be monitored. Suppresses alarms. Useful if a subrack has only one fan for some re…
1.3.6.1.4.1.8708.2.11.2.5.1.1.7ColumnequipmentFanOperStatusread-onlycurrentThe operational state of the fan module. Note: It is not possible to distinguish between a missing fan and a failed fan. Therefore 'notPresent' is currently no…
1.3.6.1.4.1.8708.2.11.2.5.1.1.8ColumnequipmentFanRowStatusread-writecurrentManages creation and deletion of conceptual rows. See also SNMPv2-TC.
1.3.6.1.4.1.8708.2.11.2.5.1.1.9ColumnequipmentFanUnitFailedread-onlycurrentThe fan module has failed or is absent. A(ctivation): Active HW indication. D(e-activation): Inactive HW indication.
1.3.6.1.4.1.8708.2.11.2.5.1.1.10ColumnequipmentFanMainUnitFailedread-onlycurrentThe main fan module has failed or is absent. A(ctivation): Active HW indication. D(e-activation): Inactive HW indication.
1.3.6.1.4.1.8708.2.11.2.5.1.1.11ColumnequipmentFanObjectPropertyread-onlycurrentProperty mask.
1.3.6.1.4.1.8708.2.11.2.5.1.1.12ColumnequipmentFanFanFaultread-onlycurrentThe Fan malfunction or fan speed differs from the set speed. A(ctivation): Active HW indication. D(e-activation): Inactive HW indication.
1.3.6.1.4.1.8708.2.11.2.5.1.1.13ColumnequipmentFanAidread-onlycurrentThe access identifier (AID) of the product. The format is according to GR-833.
1.3.6.1.4.1.8708.2.11.2.5.1.1.14ColumnequipmentFanPhysicalLocationread-onlycurrentThe Physical location of the product. The format is according to GR-833.
1.3.6.1.4.1.8708.2.11.2.6NodelumentisEquipmentNotifications
1.3.6.1.4.1.8708.2.11.2.6.0NodeequipmentNotifyPrefix
1.3.6.1.4.1.8708.2.11.2.6.0.1NotificationequipmentBoardRowStatusActivecurrentSent when a board is added to the configuration.
1.3.6.1.4.1.8708.2.11.2.6.0.2NotificationequipmentBoardRowStatusDestroydeprecatedSent when a board is removed from the configuration.
1.3.6.1.4.1.8708.2.11.2.6.0.3NotificationequipmentBoardRowStatusInsertedcurrentSent when a board is physically inserted.
1.3.6.1.4.1.8708.2.11.2.6.0.4NotificationequipmentBoardRowStatusRemovedcurrentSent when a board is physically removed.
1.3.6.1.4.1.8708.2.11.2.6.0.5NotificationequipmentBoardRowStatusDeletedcurrentSent when a board is deleted from the configuration.
1.3.6.1.4.1.8708.2.11.2.7NodeequipmentNode
1.3.6.1.4.1.8708.2.11.2.7.1ScalarequipmentNodeLedTestread-writecurrentLED test for the network element. off - Normal operation. on - Light all leds.
1.3.6.1.4.1.8708.2.11.2.7.2ScalarequipmentNodeIcnRedundancyModeread-writecurrentIndicates whether the internal communication network between sub-racks, ICN3 and ICN4, can be connected in a redundant manner or not. disabled - Non-redundant …
1.3.6.1.4.1.8708.2.11.2.7.3ScalarequipmentNodeMemoryProfileread-onlycurrentIndicates whether memory profilation shall be done or not. disabled - No memory profile enabled - Memory profile done
1.3.6.1.4.1.8708.2.11.2.7.4ScalarequipmentAllowDummyPassiveSlotsread-writecurrentThis option is applicable for TM-3000 subracks only. Normally passive boards can only be created in slots 13-22. Enabling this options allows the user to creat…
1.3.6.1.4.1.8708.2.11.2.7.5ScalarequipmentNodeManagementVlanread-writecurrentIndicates if VLAN is available (via DCN for nodes with cu) or not. off - No bridging of VLAN. (mgmtVlan off in node) bridge2dcn - VLAN is bridged to DCN. (mgmt…
1.3.6.1.4.1.8708.2.11.2.7.6ScalarequipmentNodeMgmtVlanPrivacyread-writecurrentSet Mgmt Vlan privacy. Setting is for main subrack in node. Boards affected (in R14.0) is gbeMxp10GFEC, msMxp10G, gbe10Emxp10G and gbe22Emxp10G. isolated - pri…
1.3.6.1.4.1.8708.2.11.2.7.7ScalarequipmentNodeDcnRedundancyModeread-writecurrentIndicates whether the DCN ports on a CU, DCN1 and DCN2, can be connected in a redundant manner or not. disabled - Non-redundant DCN connection. Both DCN ports …
1.3.6.1.4.1.8708.2.11.2.7.8ScalarequipmentNodeProxyArpread-writecurrentIndicates if the Proxy ARP functionality is used. Using Proxy ARP simplifies the IP-address allocation and minimizes the use of different subnets in the networ…
1.3.6.1.4.1.8708.2.11.2.8NodeequipmentResource
1.3.6.1.4.1.8708.2.11.2.8.1ScalarequipmentResourceNumberOfBoardsread-onlycurrentThe number of boards, active and passive, currently in use in this system
1.3.6.1.4.1.8708.2.11.2.8.2ScalarequipmentResourceMaxNumberOfBoardsread-onlycurrentThe maximum number of boards, active and passive, that is supported by the embedded software of this system
1.3.6.1.4.1.8708.2.11.2.8.3ScalarequipmentResourceNumberOfActiveBoardsread-onlycurrentThe number of active boards running on this system
1.3.6.1.4.1.8708.2.11.2.8.4ScalarequipmentResourceMaxNumberOfActiveBoardsread-onlycurrentThe maximum number of active boards that is supported by the embedded software of this system.
1.3.6.1.4.1.8708.2.11.2.9NodeequipmentSlot
1.3.6.1.4.1.8708.2.11.2.9.1TableequipmentSlotTablenot-accessiblecurrentThe slot list.
1.3.6.1.4.1.8708.2.11.2.9.1.1RowequipmentSlotEntrynot-accessiblecurrentAn entry in the slot list. One entry for each slot.
1.3.6.1.4.1.8708.2.11.2.9.1.1.1ColumnequipmentSlotIndexread-onlycurrentAn arbitrary index assigned to each slot entry.
1.3.6.1.4.1.8708.2.11.2.9.1.1.2ColumnequipmentSlotNameread-onlycurrentThe name of the slot, for example 'tpmr2500:1:2' where the first number indicates in which sub-rack the slot is present and the second number in which slot.
1.3.6.1.4.1.8708.2.11.2.9.1.1.3ColumnequipmentSlotSubrackread-onlycurrentThe number of the subrack in which the slot is present.
1.3.6.1.4.1.8708.2.11.2.9.1.1.4ColumnequipmentSlotSlotread-onlycurrentThe slot number.
1.3.6.1.4.1.8708.2.11.2.9.1.1.5ColumnequipmentSlotAdminStatusread-writecurrentThe administrative state of the slot. down - The slot is not monitored. up - The interface should be activated.
1.3.6.1.4.1.8708.2.11.2.9.1.1.6ColumnequipmentSlotUsageStateread-onlycurrentTells if the slot is used or not. used - Slot is used. notUsed - Slot is not used.
1.3.6.1.4.1.8708.2.11.2.9.1.1.7ColumnequipmentSlotEmptySlotread-onlycurrentSlot is empty, alarm only applicable for systems with mendatory slot usage A: Slot is empty. D: No empty slot.
1.3.6.1.4.1.8708.2.11.2.9.1.1.8ColumnequipmentSlotEquippedread-onlycurrentIs the entity equipped.
1.3.6.1.4.1.8708.2.11.2.9.1.1.9ColumnequipmentSlotAidread-onlycurrentThe access identifier (AID) of the slot. The format is according to GR-833.
1.3.6.1.4.1.8708.2.11.2.9.1.1.10ColumnequipmentSlotPhysicalLocationread-onlycurrentThe physical location of the slot. The format is according to GR-833.
1.3.6.1.4.1.8708.2.11.2.10NodeequipmentOpticalModuleList
1.3.6.1.4.1.8708.2.11.2.10.1TableequipmentOpticalModuleTablenot-accessiblecurrentThe module list.
1.3.6.1.4.1.8708.2.11.2.10.1.1RowequipmentOpticalModuleEntrynot-accessiblecurrentAn entry in the module list.
1.3.6.1.4.1.8708.2.11.2.10.1.1.1ColumnequipmentOpticalModuleIndexread-onlycurrentAn arbitrary index assigned to each entry.
1.3.6.1.4.1.8708.2.11.2.10.1.1.2ColumnequipmentOpticalModuleHostBoardTyperead-onlycurrentThe actual board type hosting the optical module.
1.3.6.1.4.1.8708.2.11.2.10.1.1.3ColumnequipmentOpticalModuleTyperead-onlycurrentThe type of optical module, for example monitor, switch, wss, amp etc
1.3.6.1.4.1.8708.2.11.2.10.1.1.4ColumnequipmentOpticalModuleNameread-onlycurrentThe management name of the interface, for example 'module:[HostBoardType]:[ moduleType]:[subrack]:[slot]'.
1.3.6.1.4.1.8708.2.11.2.10.1.1.5ColumnequipmentOpticalModuleSubrackread-onlycurrentThe number of the subrack where the module is located.
1.3.6.1.4.1.8708.2.11.2.10.1.1.6ColumnequipmentOpticalModuleSlotread-onlycurrentThe number of the slot where the module is located.
1.3.6.1.4.1.8708.2.11.2.10.1.1.7ColumnequipmentOpticalModuleFirmwareVersionread-onlycurrentFirmware version of the module.
1.3.6.1.4.1.8708.2.11.2.10.1.1.8ColumnequipmentOpticalModuleSerialNumberread-onlycurrentSerial number of the module.
1.3.6.1.4.1.8708.2.11.2.10.1.1.9ColumnequipmentOpticalModuleWarmingUpStateread-onlycurrentModule is warming up, the optics has not reached a stable state. True: Module is warming up. False: Module is ready and optics have reached stable state.
1.3.6.1.4.1.8708.2.11.2.10.1.1.10ColumnequipmentOpticalModuleFailureread-onlycurrentThe module is experiencing a failure. A(ctivation): The module has failed D(e-activation): The module is OK again
Type Definitions
NameSyntaxStatusDescription
EquipmentBoardTypeINTEGER { undefined (0), cu (1), tpMr2500 (2), oxc8 (3), oxc16 (4), ocu2 (5), mxp028 (6), ad1AB (7), ad1BA (8), ad2AB (9), ad2BA (10), ad4AB (11), ad4BA (12), tpDGbE (13), oa (14), mdu8Ext (15), mdu8Term (16), ocu4 (17), mxp004 (18), ad2oaAB (19), ad2oaBA (20), oa2 (21), adcwdm (22), ad1spr (23), tp10G (24), tpLMr2500 (25), cu1osc (26), cu2osc (27), obu (28), sync2Mhz (29), mxp8 (30), mxp16 (31), tpDGbED (32), tpDGbEC (33), tpDFcD (34), tpDFcC (35), tpFcGbED (36), tpFcGbEC (37), tpTFcD (38), tpQMr (39), mdu4TermAB (40), mdu4TermBA (41), ad1cwdm (42), ad2cwdm (43), tp10GLAN (44), tp10GRC (45), escon8 (46), oa1x15dBm (47), oa2x15dBm (48), gxp2500 (49), gxp2500Sfp (50), gxp10G (51), tpDGbEDv2 (52), tpDGbESfp (53), tpDFcDv2 (54), tpDFcSfp (55), ad2x1cwdm (56), ad2x2cwdm (57), mdu8Term2 (58), tpDDGbE (59), fpuOas2824 (60), mu2F8C (61), du2F8C (62), tpD10GL (63), tpDDGbER (64), tp10GBu (65), tp10GLANBu (66), tp10GClBu (67), tp10GLANClBu (68), mdu8EvenExt (69), mdu8EvenTerm (70), oapre1x17dBm (71), oa2x17dBm (72), oiuc100200 (73), oapow1x17dBm (74), oa1x17dBm (75), gbe9Mxp10G (76), ad1dwdm2F (77), ad1cwdm2F (78), mdu4Ext2F (79), mdu4Term2F (80), voa8ch (81), oa1x20dBm (82), oa2x20dBm (83), fpuYm235 (84), ad4dwdm2F (85), tpQMri (86), oar450c (87), cuSfp (88), tpMr25v2 (89), tpD10GbE (90), tpD10GbER (91), mdu4ExtAB (92), mdu4ExtBA (93), oiuc50100 (94), mROADM1P800 (95), edu6pGbE (96), tp10GClTc (97), mxp4x2G5 (98), oa1xLG20dBm (99), oa2xLG20dBm (100), oa1xFG10dBm (101), oa2xFG10dBm (102), tp10GOtnTc (103), mdu40Even (104), mdu40Odd (105), mdu8Ee (106), mdu8Eo (107), ocm2p (108), msMxp (109), voa8chii (110), msMxpR (111), msMxpDQgbe (112), tp10GTcEr (113), gbe10Emxp10G (114), edu12pGbE (115), gbeMxp10GFEC (116), roadm1x4G100 (117), dQgbeMxpR (118), tpQMS (119), tpQMSR (120), gbe22Emxp10G (121), oa1x26dBm(122), pcu2p (123), mxp4x2G5Oc (124), voa2ch (125), msMxp10GTCEr (126), msMxp10G (127), msMxpQMS2G5 (128), gbe22Emxp10Gii (129), bsu1x5Even (130), bsu1x5Odd (131), gbe10Emxp10Gii (132), mba1 (133), mba1SonetDeprecated (134), mba2 (135), mba2SonetDeprecated (136), mxpmbh1Sdh (137), mxpmbh1Sonet (138), roadm1x8G50 (139), ad4Even50 (140), ad4Odd50 (141), emxp80Gii (142), msMxpQMS2G5R (143), mxp8iiSdh (144), mxp8iiSonet (145), mba2E (146), mba2ptpSdh (147), mba2ptpSonet (148), mba2EptpSdh (149), mba2EptpSonet (150), mdu40EvenL (151), mdu40OddL (152), oa1x20dBmVg (153), oa2x20dBmVg (154), roadm1x2G100 (155), roadm1x2G50 (156), tpq10Gfec (157), cuSfpii (158), coD40ev (159), coD40eve (160), coD40od (161), coD40ode (162), dcDk652km20 (163), dcDk652km40 (164), dcDk652km60 (165), dcDk652km80 (166), dcP652km40 (167), dcP652km60 (168), dcP652km80 (169), dcP652km100 (170), dcP652km120 (171), emxp40Gii (172), tpqmp (173), tpq10GfecReg (174), mdu16cl50g (175), voa8chsfp (176), msTp40G (177), msMxp40G(178), mxp10gotn (179), emxp62iie (180), emxp120iie (181), ocudq (182), tm4700 (183), tm4011 (184), tm100mxp (185), tm100tp (186), tm100reg (187), ocuseed2p (188), oa2x21seed (189), oypatchcord (190), tpq10gfeci (191), tpq10gfecregi (192), tphex10gotn (193), emxp48iie (194), tp100gotn (195), emxp220iie (196), tpmrHL16G (197), fhmxp10g (198), mxp100gotn (199), cuSfpiii (200), emxp240iie (201), tpmrHL16GUni (202), fpu1 (203), oaraed21hghyb (204), oaraed21hgind (205), emxp3 (206), dcDk652km100 (207), dcDk652km120 (208), dcP652km20 (209), fhau1(210), fha1u1(211), oa1x20dBmVg2 (212), oa2x20dBmVg2 (213), ptio10g (214), fxp400gotn (215), compo24 (216), rfu1 (217), coD919926 (218), coD927934 (219), coD935942 (220), coD943950 (221), coD951958 (222), coD919926e (223), coD927934e (224), coD935942e (225), coD943950e (226), coD951958e (227), co4 (228), co5 (229), codsf20eva (230), codsf20evb (231), codsf4919 (232), codsf4926 (233), codsf4927 (234), codsf4934 (235), codsf4935 (236), codsf4942 (237), codsf4943 (238), codsf4950 (239), codsf4951 (240), codsf4958 (241), codsf2919 (242), codsf2922 (243), codsf2923 (244), codsf2926 (245), codsf2927 (246), codsf2930 (247), codsf2931 (248), codsf2934 (249), codsf2935 (250), codsf2938 (251), codsf2939 (252), codsf2942 (253), codsf2943 (254), codsf2946 (255), codsf2947 (256), codsf2950 (257), codsf2951 (258), codsf2954 (259), codsf2955 (260), codsf2958 (261), tp100gotnii (262), roadm1x4f (263), ptio100g (264), oadm2ch (265), emxp1u(266), emxp1us(267), mxp200gotn (268), emxp440 (269), oaraed20lghyb (270), roadm1x9f (271), ocm8p (272), ad1c2fotdr (273), hdea1600 (274), oa1xLG20dBmb (275), oa2xLG20dBmb (276), oa1x20dBmVgb (277), oa2x20dBmVgb (278), codsf24mpo10104 (279), otdr8p (280), coD48ev (281), coD48od (282), emxp440q (283), oa1x21dBmVgEC (284), oa2x21dBmVgEC (285), co10 (286), emxp800xh (287), coocuD4x4 (288), coocuD4x8 (289), cooiuc50100 (290), co2xOTDR1611 (291), coD4919 (292), coD4923 (293), coD4927 (294), coD4931 (295), coD4935 (296), coD4939 (297), coD4943 (298), coD4947 (299), coD4951 (300), coD4955 (301), tgCo4 (1001), tgCo5 (1005), tgCo6 (1006), tgCo7 (1007), tgCo8 (1008), tgCo9 (1009), tgCo10 (1010), tgCo11 (1011), tgCo12 (1012), tgCo14 (1014), tgCo15 (1015), tgCo16 (1016), tgCoDxxxyyy (1040), tgCoD40ev (1041), tgCoD40eve (1042), tgCoD40od (1043), tgCoD40ode (1044), tgCoBSU1x5ev (1050), tgCoBSU1x5od (1051), tgCad86XX04 (1055), tgCad86XX02 (1056), tgCoDSF2ch9XXAB (1057), tgCoDSF4ch9XXAB (1058), tgCoDSF2ch9XXBA (1059), tgCoDSF4ch9XXBA (1060), tgTcosf2x1b (1061), tgTcosf2x1d (1062), tgCoD4XXX (1070), tgCoDSF20 (1080), tgCoDSF20evA (1081), tgCoDSF20evB (1082), tgCoDSF20odA (1083), tgCoDSF20odB (1084), tgCoSFBSU1x5ev (1085), tgTco12 (2012), tgTco14 (2014), acd2pGbE (10000), acd5pGbE (10001), acd10G (10002), edu5GT (10003), edu10GLT (10004), edu10GLTS (10005), nidGE (20000), nidSfp155 (20001), nidSfp622 (20002), nidSfpVc12 (20003), nidSfp2488 (20004), ts1100EthMux4p (220401), ts1100OPU (250101), ts1100OPUDouble (250201), ts1100PreAmpDouble (260401), ts1100PreAmp (261001), ts1100AttenuatorDouble (270001), ts1100UnivAggDGbE (540001), ts1100UnivAggDFC (540002), ts1100UnivAggDGbE2 (540003), ts1100UnivAgg (550000), ts1100UnivAgg4xGbE (580000), ts1100UnivAgg2xDGbE (5800002), ts1100UnivAgg3xGbERep (5800003), ts1100UnivAgg3x25GRep (5800004), ts1100UnivAgg2xGbE2xSTM (581000), ts1100UnivAgg4xGbE2 (5810002), ts1100UnivAgg3xGbERep2 (5810003), ts1100Muxponder10G (590000), ts1100Muxponder10G2 (5900002), ts1100Nmb (600100), ts1100Nmb6003 (600300), ts1100Tp2x4GFC (740001), ts1100Conv1250Cwdm (750000), ts1100Conv2500Cwdm (760000), ts1100Tp2500Cwdm1 (770000), ts1100Tp2x2500Cwdm1 (772000), ts1100Tp10G (790000), ts1100Tp10G7910 (791000), ts1100Tp10G7910Rep (7910002), ts1100DuplexerDouble (802001), ts1100MuxDemux4chPizza (803000), ts1100MuxDemux4chExtPizza (803100), ts1100MuxDemux8chPizza (803200), ts1100MuxDemux8chExtPizza (803300), ts1100Duplexer (812001), ts1100MuxDemux4ch1t4 (813001), ts1100MuxDemux4p1ch1t4 (813101), ts1100MuxDemux8ch (813200), ts1100MuxDemux8p1ch (813300), ts1100MuxDemux8ch2 (813400), ts1100MuxDemux4ch5t8 (814001), ts1100MuxDemux4p1ch5t8 (814101), ts1100MuxDemux4chBidir (823000), ts1100AddDropDouble (850100), ts1100AddDrop (870101), ts1100AddDropSingle (870102), ts1100DWDMMuxDemuxExt (883001), ts1100DWDMMuxDemux (883101), ts1100Power9000Supply (900000), ts1100Power9048Supply (904800), ts1100Power9122Supply (912200), ts1100Power9148Supply (914800), ts1100Power9220Supply (922000), tm206Fan (9200201), tm206OSC1 (9221001), tm206OSC2 (9221002), tm206TAM4xesc (9500101), tm206TAMln4xesc (9510101), tm206TAMln4xetr (9510201), tm206TAMlnFlex (9510301), tm206TAMln2xfc (9510401), tm206TAMlnp2xfc (9510501), tm206Cu (9600201), tm206Cu2 (9600202), tm206tp2x4gfc (9780001), tm206MuxDemux4ch1t4 (9813001), tm206MuxDemux4p1ch1t4 (9813101), tm206MuxDemux4ch5t8 (9814001), tm206MuxDemux4p1ch5t8 (9814101), tm206MuxDemux4chBidir1 (9823001), tm206MuxDemux4chBidir2 (9823002), tm206AddDrop (9870101) }currentThe functional type of the board. At least one type is defined for each combination of the following properties of the board: 1 - number of interfaces 2 - type of interfaces 3 - the functionality of the board (can usual…
EquipmentSubrackTypeINTEGER { undefined (0), tm300 (1), tm3000 (2), tm301 (3), tm101 (4), tm101p (5), aux (6), tm102 (7), mba1 (8), mba2 (9), mba2E (10), tm102pas (11), tm102pas3 (12), tm3000ii (13), tm2000 (14), tm301ii (15), tmFha1UDc1 (16), tmRfuAc1 (17), tmEmxp1UDc (18), tmHdea1600Dc (19), tm3000iie (20), tmEmxpXh800Dc (21), ts1100Subrack2Slots (9002), tm206Subrack6Slots (9006), ts1100Subrack8Slots (9011), ts1100Subrack12Slots (9013) }currentThe type of subrack: tm300 - The small subrack (old). tm3000 - The big subrack. tm3000ii - The big subrack, enhanced version. tm3000iie - The big subrack, enhanced second version. tm301 - The small subrack (new). tm301i…
FirstPbSlotINTEGER { undefined(0), slot3(3), slot4(4), slot13(13) }currentA value indicating the first slot where it is possible to configure a passive board in a subrack. undefined - indicates that no value has yet been set. slot3 - Slot 3 is the first passive slot. slot4 - Slot 4 is the fir…