LUM-EQUIPMENT-MIB
293 objects
The common equipment configuration MIB. - General - Subrack status - Board configuration and status - Power supply status - Fan status - Slot
Imported Objects
| LUM-ALARM-MIB MISSING | AlarmPerceivedSeverity |
| LUM-REG | lumEquipmentMIB lumModules |
| LUM-TC MISSING | AdminStatus BoardOrInterfaceAdminStatus BoardOrInterfaceOperStatus CommandString FaultStatus MgmtNameString ObjectProperty SlotNumber SubrackNumber TruthValueWithNA |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DateAndTime DisplayString RowStatus TestAndIncr TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.8708.1.1.12 | IdentitylumEquipmentMIBModule | The common equipment configuration MIB. - General - Subrack status - Board configuration and status - Power supply status - Fan status - Slot | ||
| 1.3.6.1.4.1.8708.2.11.1 | NodelumEquipmentConfs | |||
| 1.3.6.1.4.1.8708.2.11.1.1 | NodelumEquipmentGroups | |||
| 1.3.6.1.4.1.8708.2.11.1.1.1 | GroupequipmentGeneralGroup | current | The general objects. | |
| 1.3.6.1.4.1.8708.2.11.1.1.2 | GroupequipmentSubrackGroup | deprecated | The subrack module objects. | |
| 1.3.6.1.4.1.8708.2.11.1.1.3 | GroupequipmentBoardGroup | deprecated | The board objects. | |
| 1.3.6.1.4.1.8708.2.11.1.1.4 | GroupequipmentPowerGroup | deprecated | The power module objects. | |
| 1.3.6.1.4.1.8708.2.11.1.1.5 | GroupequipmentFanGroup | deprecated | The fan module objects. | |
| 1.3.6.1.4.1.8708.2.11.1.1.6 | GroupequipmentGeneralGroupV2 | deprecated | The equipment general objects v2. | |
| 1.3.6.1.4.1.8708.2.11.1.1.7 | GroupequipmentNotificationGroup | deprecated | The equipment notifications. | |
| 1.3.6.1.4.1.8708.2.11.1.1.8 | GroupequipmentSubrackGroupV2 | deprecated | The subrack module objects V2. | |
| 1.3.6.1.4.1.8708.2.11.1.1.9 | GroupequipmentSubrackGroupV3 | deprecated | The subrack module objects V3. | |
| 1.3.6.1.4.1.8708.2.11.1.1.10 | GroupequipmentBoardGroupV2 | deprecated | The board objects V2. | |
| 1.3.6.1.4.1.8708.2.11.1.1.11 | GroupequipmentNodeGroup | deprecated | The node objects. | |
| 1.3.6.1.4.1.8708.2.11.1.1.12 | GroupequipmentGeneralGroupV3 | deprecated | The equipment general objects v3. | |
| 1.3.6.1.4.1.8708.2.11.1.1.13 | GroupequipmentNodeGroupV2 | deprecated | The node objects. | |
| 1.3.6.1.4.1.8708.2.11.1.1.14 | GroupequipmentNodeGroupV3 | deprecated | The node objects. | |
| 1.3.6.1.4.1.8708.2.11.1.1.15 | GroupequipmentSubrackGroupV4 | deprecated | The subrack module objects V4. | |
| 1.3.6.1.4.1.8708.2.11.1.1.16 | GroupequipmentBoardGroupV3 | deprecated | The board objects V3. | |
| 1.3.6.1.4.1.8708.2.11.1.1.17 | GroupequipmentNotificationGroupV2 | deprecated | The equipment notifications. | |
| 1.3.6.1.4.1.8708.2.11.1.1.18 | GroupequipmentSubrackGroupV5 | deprecated | The subrack module objects V5. (2.2) | |
| 1.3.6.1.4.1.8708.2.11.1.1.19 | GroupequipmentFanGroupV2 | deprecated | The fan module objects. | |
| 1.3.6.1.4.1.8708.2.11.1.1.20 | GroupequipmentGeneralGroupV4 | deprecated | The equipment general objects v4 (3.1). | |
| 1.3.6.1.4.1.8708.2.11.1.1.21 | GroupequipmentSubrackGroupV6 | deprecated | The subrack module objects V6. (4.0) | |
| 1.3.6.1.4.1.8708.2.11.1.1.22 | GroupequipmentBoardGroupV4 | deprecated | The board objects V4. (4.0) | |
| 1.3.6.1.4.1.8708.2.11.1.1.23 | GroupequipmentPowerGroupV2 | deprecated | The power module objects (4.0). | |
| 1.3.6.1.4.1.8708.2.11.1.1.24 | GroupequipmentFanGroupV3 | deprecated | The fan module objects (4.0). | |
| 1.3.6.1.4.1.8708.2.11.1.1.25 | GroupequipmentNodeGroupV4 | deprecated | The node objects V4 (7.0) | |
| 1.3.6.1.4.1.8708.2.11.1.1.26 | GroupequipmentBoardGroupV5 | deprecated | The board objects V5. (7.0) | |
| 1.3.6.1.4.1.8708.2.11.1.1.27 | GroupequipmentBoardGroupV6 | deprecated | The board objects V6. (8.0) | |
| 1.3.6.1.4.1.8708.2.11.1.1.28 | GroupequipmentBoardGroupV7 | deprecated | The board objects V7. (9.0) | |
| 1.3.6.1.4.1.8708.2.11.1.1.29 | GroupequipmentNodeGroupV8 | deprecated | The node objects V8 (11.0) | |
| 1.3.6.1.4.1.8708.2.11.1.1.30 | GroupequipmentBoardGroupV8 | deprecated | The board objects V8. (12.0) | |
| 1.3.6.1.4.1.8708.2.11.1.1.31 | GroupequipmentNodeGroupV9 | deprecated | The node objects V9 (14.0) | |
| 1.3.6.1.4.1.8708.2.11.1.1.32 | GroupequipmentResourceGroup | current | The resouce objects V1 (16.0) | |
| 1.3.6.1.4.1.8708.2.11.1.1.33 | GroupequipmentSubrackGroupV7 | deprecated | The subrack module objects V7. (16.0) | |
| 1.3.6.1.4.1.8708.2.11.1.1.34 | GroupequipmentSubrackGroupV8 | deprecated | The subrack module objects V8. (17.0) | |
| 1.3.6.1.4.1.8708.2.11.1.1.35 | GroupequipmentBoardGroupV9 | deprecated | The board objects V9. (17.0) | |
| 1.3.6.1.4.1.8708.2.11.1.1.36 | GroupequipmentNotificationGroupV3 | current | The equipment notifications. | |
| 1.3.6.1.4.1.8708.2.11.1.1.37 | GroupequipmentBoardGroupV10 | deprecated | The board objects V10. (17.0) | |
| 1.3.6.1.4.1.8708.2.11.1.1.38 | GroupequipmentNodeGroupV10 | deprecated | The node objects V10 (18.0) | |
| 1.3.6.1.4.1.8708.2.11.1.1.40 | GroupequipmentBoardGroupV11 | deprecated | The board objects V11. (20.0) | |
| 1.3.6.1.4.1.8708.2.11.1.1.41 | GroupequipmentFanGroupV4 | deprecated | The fan module objects V4. (20.0) | |
| 1.3.6.1.4.1.8708.2.11.1.1.42 | GroupequipmentSlotGroup | deprecated | The slot module objects. (20.0) | |
| 1.3.6.1.4.1.8708.2.11.1.1.43 | GroupequipmentBoardGroupV12 | deprecated | The board objects V12. (21.0) | |
| 1.3.6.1.4.1.8708.2.11.1.1.44 | GroupequipmentNodeGroupV11 | current | The node objects V11 (21.0) | |
| 1.3.6.1.4.1.8708.2.11.1.1.45 | GroupequipmentBoardGroupV13 | deprecated | The board objects V13. (27.0) | |
| 1.3.6.1.4.1.8708.2.11.1.1.46 | GroupequipmentPowerGroupV3 | deprecated | The power module objects V3 (27.0). | |
| 1.3.6.1.4.1.8708.2.11.1.1.47 | GroupequipmentBoardGroupV14 | current | The board objects V14. (28.0) | |
| 1.3.6.1.4.1.8708.2.11.1.1.48 | GroupequipmentSlotGroupV2 | current | The slot module objects V2. (28.0) | |
| 1.3.6.1.4.1.8708.2.11.1.1.49 | GroupequipmentSubrackGroupV9 | deprecated | The subrack module objects V9. (28.0) | |
| 1.3.6.1.4.1.8708.2.11.1.1.50 | GroupequipmentPowerGroupV4 | deprecated | The power module objects V4 (28.0). | |
| 1.3.6.1.4.1.8708.2.11.1.1.51 | GroupequipmentFanGroupV5 | current | The fan module objects V5. (28.0) | |
| 1.3.6.1.4.1.8708.2.11.1.1.52 | GroupequipmentGeneralGroupV5 | deprecated | The equipment general objects v5 (R28.0). | |
| 1.3.6.1.4.1.8708.2.11.1.1.53 | GroupequipmentSubrackGroupV10 | current | The subrack module objects V10. (29.0) | |
| 1.3.6.1.4.1.8708.2.11.1.1.54 | GroupequipmentGeneralGroupV6 | current | The equipment general objects v6 (R31.0). | |
| 1.3.6.1.4.1.8708.2.11.1.1.55 | GroupequipmentOpticalModuleGroup | current | The equipment optical module objects v6 (R31.0). | |
| 1.3.6.1.4.1.8708.2.11.1.1.56 | GroupequipmentPowerGroupV5 | current | The power module objects V5 (32.1). | |
| 1.3.6.1.4.1.8708.2.11.1.2 | NodelumEquipmentCompl | |||
| 1.3.6.1.4.1.8708.2.11.1.2.1 | CompliancelumEquipmentBasicComplV1 | deprecated | Basic implementation requirements for the equipment MIB. | |
| 1.3.6.1.4.1.8708.2.11.1.2.2 | CompliancelumEquipmentBasicComplV2 | deprecated | Basic implementation requirements for the equipment MIB V2. | |
| 1.3.6.1.4.1.8708.2.11.1.2.3 | CompliancelumEquipmentBasicComplV3 | deprecated | Basic implementation requirements for the equipment MIB V3. | |
| 1.3.6.1.4.1.8708.2.11.1.2.4 | CompliancelumEquipmentBasicComplV4 | deprecated | Basic implementation requirements for the equipment MIB V4. | |
| 1.3.6.1.4.1.8708.2.11.1.2.5 | CompliancelumEquipmentBasicComplV5 | deprecated | Basic implementation requirements for the equipment MIB V5. | |
| 1.3.6.1.4.1.8708.2.11.1.2.6 | CompliancelumEquipmentBasicComplV6 | deprecated | Basic implementation requirements for the equipment MIB V6. | |
| 1.3.6.1.4.1.8708.2.11.1.2.7 | CompliancelumEquipmentBasicComplV7 | deprecated | Basic implementation requirements for the equipment MIB V7. | |
| 1.3.6.1.4.1.8708.2.11.1.2.8 | CompliancelumEquipmentBasicComplV8 | deprecated | Basic implementation requirements for the equipment MIB V8. | |
| 1.3.6.1.4.1.8708.2.11.1.2.9 | CompliancelumEquipmentBasicComplV9 | deprecated | Basic implementation requirements for the equipment MIB V9. | |
| 1.3.6.1.4.1.8708.2.11.1.2.10 | CompliancelumEquipmentBasicComplV10 | deprecated | Basic implementation requirements for the equipment MIB V10. | |
| 1.3.6.1.4.1.8708.2.11.1.2.11 | CompliancelumEquipmentBasicComplV11 | deprecated | Basic implementation requirements for the equipment MIB V11. Equivalent to V10, but the notifications differ... | |
| 1.3.6.1.4.1.8708.2.11.1.2.12 | CompliancelumEquipmentBasicComplV12 | deprecated | Basic implementation requirements for the equipment MIB V12. | |
| 1.3.6.1.4.1.8708.2.11.1.2.13 | CompliancelumEquipmentBasicComplV13 | deprecated | Basic implementation requirements for the equipment MIB V13. (2.2) | |
| 1.3.6.1.4.1.8708.2.11.1.2.14 | CompliancelumEquipmentBasicComplV14 | deprecated | Basic implementation requirements for the equipment MIB V14. (2.3) | |
| 1.3.6.1.4.1.8708.2.11.1.2.15 | CompliancelumEquipmentBasicComplV15 | deprecated | Basic implementation requirements for the equipment MIB V15. (2.3.2) | |
| 1.3.6.1.4.1.8708.2.11.1.2.16 | CompliancelumEquipmentBasicComplV16 | deprecated | Basic implementation requirements for the equipment MIB V16. (3.0) | |
| 1.3.6.1.4.1.8708.2.11.1.2.17 | CompliancelumEquipmentBasicComplV17 | deprecated | Basic implementation requirements for the equipment MIB V17. (3.1) | |
| 1.3.6.1.4.1.8708.2.11.1.2.18 | CompliancelumEquipmentBasicComplV18 | deprecated | Basic implementation requirements for the equipment MIB V18. (4.0) | |
| 1.3.6.1.4.1.8708.2.11.1.2.19 | CompliancelumEquipmentBasicComplV19 | deprecated | Basic implementation requirements for the equipment MIB V19. (7.0) | |
| 1.3.6.1.4.1.8708.2.11.1.2.20 | CompliancelumEquipmentBasicComplV20 | deprecated | Basic implementation requirements for the equipment MIB V20. (8.0) | |
| 1.3.6.1.4.1.8708.2.11.1.2.21 | CompliancelumEquipmentBasicComplV21 | deprecated | Basic implementation requirements for the equipment MIB V21. (9.0) | |
| 1.3.6.1.4.1.8708.2.11.1.2.22 | CompliancelumEquipmentBasicComplV22 | deprecated | Basic implementation requirements for the equipment MIB V22. (10.0) | |
| 1.3.6.1.4.1.8708.2.11.1.2.23 | CompliancelumEquipmentBasicComplV23 | deprecated | Basic implementation requirements for the equipment MIB V23. (11.0) | |
| 1.3.6.1.4.1.8708.2.11.1.2.24 | CompliancelumEquipmentBasicComplV24 | deprecated | Basic implementation requirements for the equipment MIB V24. (12.0) | |
| 1.3.6.1.4.1.8708.2.11.1.2.25 | CompliancelumEquipmentBasicComplV25 | deprecated | Basic implementation requirements for the equipment MIB V24. (14.0) | |
| 1.3.6.1.4.1.8708.2.11.1.2.26 | CompliancelumEquipmentBasicComplV26 | deprecated | Basic implementation requirements for the equipment MIB V26. (16.0) | |
| 1.3.6.1.4.1.8708.2.11.1.2.27 | CompliancelumEquipmentBasicComplV27 | deprecated | Basic implementation requirements for the equipment MIB V26. (16.0) | |
| 1.3.6.1.4.1.8708.2.11.1.2.28 | CompliancelumEquipmentBasicComplV28 | deprecated | Basic implementation requirements for the equipment MIB V28. (17.0) | |
| 1.3.6.1.4.1.8708.2.11.1.2.29 | CompliancelumEquipmentBasicComplV29 | deprecated | Basic implementation requirements for the equipment MIB V28. (17.0) | |
| 1.3.6.1.4.1.8708.2.11.1.2.30 | CompliancelumEquipmentBasicComplV30 | deprecated | Basic implementation requirements for the equipment MIB V30. (18.0) | |
| 1.3.6.1.4.1.8708.2.11.1.2.31 | CompliancelumEquipmentBasicComplV31 | deprecated | Basic implementation requirements for the equipment MIB V31. (20.0) | |
| 1.3.6.1.4.1.8708.2.11.1.2.32 | CompliancelumEquipmentBasicComplV32 | deprecated | Basic implementation requirements for the equipment MIB V32. (21.0) | |
| 1.3.6.1.4.1.8708.2.11.1.2.33 | CompliancelumEquipmentBasicComplV33 | deprecated | Basic implementation requirements for the equipment MIB V33. (27.0) | |
| 1.3.6.1.4.1.8708.2.11.1.2.34 | CompliancelumEquipmentBasicComplV34 | deprecated | Basic implementation requirements for the equipment MIB V34. (28.0) | |
| 1.3.6.1.4.1.8708.2.11.1.2.35 | CompliancelumEquipmentBasicComplV35 | deprecated | Basic implementation requirements for the equipment MIB V35. (29.0) | |
| 1.3.6.1.4.1.8708.2.11.1.2.36 | CompliancelumEquipmentBasicComplV36 | deprecated | Basic implementation requirements for the equipment MIB V36. (31.0) | |
| 1.3.6.1.4.1.8708.2.11.1.2.37 | CompliancelumEquipmentBasicComplV37 | current | Basic implementation requirements for the equipment MIB V37. (32.1) | |
| 1.3.6.1.4.1.8708.2.11.1.3 | NodelumEquipmentMinimalGroups | |||
| 1.3.6.1.4.1.8708.2.11.1.3.1 | GroupequipmentGeneralMinimalGroupV1 | current | The minimal general equipment MIB objects. | |
| 1.3.6.1.4.1.8708.2.11.1.3.2 | GroupequipmentBoardMinimalGroupV1 | deprecated | The minimal board objects. | |
| 1.3.6.1.4.1.8708.2.11.1.3.3 | GroupequipmentBoardMinimalGroupV2 | current | The minimal board objects. | |
| 1.3.6.1.4.1.8708.2.11.1.4 | NodelumEquipmentMinimalCompl | |||
| 1.3.6.1.4.1.8708.2.11.1.4.1 | CompliancelumEquipmentMinimalComplV1 | deprecated | Minimal implementation requirements for the equipment MIB V1. | |
| 1.3.6.1.4.1.8708.2.11.1.4.2 | CompliancelumEquipmentMinimalComplV2 | deprecated | Minimal implementation requirements for the equipment MIB V2. | |
| 1.3.6.1.4.1.8708.2.11.1.4.3 | CompliancelumEquipmentMinimalComplV3 | deprecated | Minimal implementation requirements for the equipment MIB V3. | |
| 1.3.6.1.4.1.8708.2.11.1.4.4 | CompliancelumEquipmentMinimalComplV4 | current | Minimal implementation requirements for the equipment MIB V4. | |
| 1.3.6.1.4.1.8708.2.11.1.4.5 | CompliancelumEquipmentMinimalComplV5 | deprecated | Minimal implementation requirements for the equipment MIB V5. | |
| 1.3.6.1.4.1.8708.2.11.1.4.6 | CompliancelumEquipmentMinimalComplV6 | current | Minimal implementation requirements for the equipment MIB V6. | |
| 1.3.6.1.4.1.8708.2.11.2 | NodelumEquipmentMIBObjects | |||
| 1.3.6.1.4.1.8708.2.11.2.1 | NodeequipmentGeneral | |||
| 1.3.6.1.4.1.8708.2.11.2.1.1 | ScalarequipmentGeneralTestAndIncr | read-write | current | Protection against simultaneous access from multiple managers. See SNMPv2-TC. |
| 1.3.6.1.4.1.8708.2.11.2.1.2 | ScalarequipmentGeneralMibSpecVersion | read-write | current | The MIB specification version. tbd: persistent? |
| 1.3.6.1.4.1.8708.2.11.2.1.3 | ScalarequipmentGeneralMibImplVersion | read-write | current | The MIB implementation version. |
| 1.3.6.1.4.1.8708.2.11.2.1.4 | ScalarequipmentGeneralLastChangeTime | read-only | current | The time when the configuration of the MIB was last changed. |
| 1.3.6.1.4.1.8708.2.11.2.1.5 | ScalarequipmentGeneralStateLastChangeTime | read-only | current | The time when the state of the MIB was last changed. |
| 1.3.6.1.4.1.8708.2.11.2.1.6 | ScalarequipmentGeneralEquipmentSubrackTableSize | read-only | current | Size of table |
| 1.3.6.1.4.1.8708.2.11.2.1.7 | ScalarequipmentGeneralEquipmentBoardTableSize | read-only | current | Size of table |
| 1.3.6.1.4.1.8708.2.11.2.1.8 | ScalarequipmentGeneralEquipmentPowerTableSize | read-only | current | Size of table |
| 1.3.6.1.4.1.8708.2.11.2.1.9 | ScalarequipmentGeneralEquipmentFanTableSize | read-only | current | Size of table |
| 1.3.6.1.4.1.8708.2.11.2.1.10 | ScalarequipmentGeneralEquipmentSlotTableSize | read-only | current | Size of table |
| 1.3.6.1.4.1.8708.2.11.2.1.11 | ScalarequipmentGeneralEquipmentOpticalModuleTableSize | read-only | current | Size of table |
| 1.3.6.1.4.1.8708.2.11.2.2 | NodeequipmentSubrackList | |||
| 1.3.6.1.4.1.8708.2.11.2.2.1 | TableequipmentSubrackTable | not-accessible | current | The subrack list. |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1 | RowequipmentSubrackEntry | not-accessible | current | An entry in the subrack list. |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.1 | ColumnequipmentSubrackIndex | read-only | current | An arbitrary index assigned to each subrack entry. |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.2 | ColumnequipmentSubrackName | read-only | current | The name of the subrack, for example 'sub1' where the number indicates the subrack number. |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.3 | ColumnequipmentSubrackSubrack | read-create | current | The number of the subrack. |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.4 | ColumnequipmentSubrackDescr | read-write | current | User configurable label. |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.5 | ColumnequipmentSubrackInvPhysIndexOrZero | read-only | current | The row in the invPhysTable for this subrack. Set to 0 if not known. |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.6 | ColumnequipmentSubrackAllFanUnitsFailed | read-only | current | All fan units in a subrack have failed. A(ctivation): fanUnitFailed active for all fans within a subrack. D(e-activiation): fanUnitFailed cleared for one fan u… |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.7 | ColumnequipmentSubrackRowStatus | read-create | current | SNMP administrivia. Manages creation and deletion of conceptual rows. See also SNMPv2-TC. |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.8 | ColumnequipmentSubrackExpectedType | read-write | current | The expected subrack type. |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.9 | ColumnequipmentSubrackActualType | read-only | current | The actual subrack type. If an unexpected subrack has been detected this variable can be used to see what type of subrack has been detected. |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.10 | ColumnequipmentSubrackUnexpectedType | read-only | current | A type of subrack not matching the expected type is present. A: A subrack with type different from the expected type is present (even if the subrack is not act… |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.11 | ColumnequipmentSubrackTemp | read-only | current | The temperature in the subrack in 0.1 degrees centigrade. |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.12 | ColumnequipmentSubrackTempHighExceeded | read-only | current | The threshold for environmental temperature in the subrack is exceeded. A: The temperature exceeds the associated threshold. D: Temperature is 0.5 degrees cent… |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.13 | ColumnequipmentSubrackTempThreshold | read-write | current | The threshold for temperature alarm in the subrack in 0.1 degrees centigrade. |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.14 | ColumnequipmentSubrackDataChanged | read-only | current | The subrack data (dipswitches for subrackId and/or system mode) has been changed. Changing this data might affect the system behaviour after the next restart. … |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.15 | ColumnequipmentSubrackSystemModeSet | read-only | current | The value read from the system mode dipswitches at startup of the CU was diffrent from 0. This will affect the behaviour of the system. If the lowest bit is se… |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.16 | ColumnequipmentSubrackEffectiveSystemMode | read-only | current | The value of the system mode dipswitches read at startup. This value determines the system behaviour. |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.17 | ColumnequipmentSubrackCurrentSystemMode | read-only | current | The current value of the system mode dipswitches. Will be used at the next restart. |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.18 | ColumnequipmentSubrackAdminStatus | read-write | current | The administrative state of the subrack. down - This subrack should not be monitored. Suppresses alarms. up - The subrack should be monitored. |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.19 | ColumnequipmentSubrackOperStatus | read-only | current | The operational state of the subrack. notPresent - The subrack is not available. down - The subrack remains in the 'down'-state when adminStatus is set to 'dow… |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.20 | ColumnequipmentSubrackObjectProperty | read-only | current | Property mask. |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.21 | ColumnequipmentSubrackShelfLength | read-write | current | Length of the half-height slot divider shelf. To be manually entered by the user. A value of 0 is interpreted as 'not yet defined by user'. |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.22 | ColumnequipmentSubrackLANModuleMissing | read-only | current | The subrack LAN/DCN module is missing. A(ctivation): LAN/DCN module disconnected from subrack for more than 2 seconds. D(e-activiation): LAN/DCN module connect… |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.23 | ColumnequipmentSubrackExpectedFirstPbSlot | read-write | current | The lowest slot number where it is possible to configure a passive board. Automatically configured to the actual value supported by hardware if the hardware is… |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.24 | ColumnequipmentSubrackActualFirstPbSlot | read-only | current | The actual lowest slot number where it is possible to configure a passive board. When no subrack hardware is present, this value is 'undefined'. |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.25 | ColumnequipmentSubrackFirstPbSlotMismatch | read-only | current | The expected first passive slot allows more passive boards than the hardware supports. A(ctivation): A subrack and control unit combination which supports fewe… |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.26 | ColumnequipmentSubrackAid | read-only | current | The access identifier (AID) of the product. The format is according to GR-833. |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.27 | ColumnequipmentSubrackPhysicalLocation | read-only | current | The Physical location of the product. The format is according to GR-833. |
| 1.3.6.1.4.1.8708.2.11.2.2.1.1.28 | ColumnequipmentSubrackChangeExpectedType | read-only | current | Command to change expected type, used when upgrading subrack to a new version, e.g TM3000 to TM3000/II |
| 1.3.6.1.4.1.8708.2.11.2.3 | NodeequipmentBoardList | |||
| 1.3.6.1.4.1.8708.2.11.2.3.1 | TableequipmentBoardTable | not-accessible | current | The board list. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1 | RowequipmentBoardEntry | not-accessible | current | An entry in the board list. One entry for each slot. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.1 | ColumnequipmentBoardIndex | read-only | current | An arbitrary index assigned to each board entry. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.2 | ColumnequipmentBoardName | read-only | current | The name of the board, for example 'tpmr2500:1:2' where the first number indicates in which sub-rack the board is present and the second number in which slot. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.3 | ColumnequipmentBoardExpectedType | read-create | current | The expected board type. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.4 | ColumnequipmentBoardActualType | read-only | current | The actual board type. If an unexpected board has been detected this variable can be used to see what type of board has been detected. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.5 | ColumnequipmentBoardDescr | read-write | current | User configurable label. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.6 | ColumnequipmentBoardSubrack | read-create | current | The number of the subrack where the board is located. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.7 | ColumnequipmentBoardSlot | read-create | current | The slot where the board is located. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.8 | ColumnequipmentBoardTemp | read-only | current | The temperature on the board in 0.1 degrees centigrade. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.9 | ColumnequipmentBoardInvPhysIndexOrZero | read-only | current | The row in the invPhysTable for this board. Set to 0 if not known. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.10 | ColumnequipmentBoardLedTest | read-write | current | LED test for the board. off - Normal operation. on - Light all leds. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.11 | ColumnequipmentBoardAdminStatus | read-write | current | The administrative state of the board. down - The board should be inactive. Alarms are suppressed. service - The board is activated but alarms are suppressed. … |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.12 | ColumnequipmentBoardOperStatus | read-only | current | The operational state of the board. notPresent - The board is not available. down - The board remains in the 'down'-state when adminStatus is set to 'down' or … |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.13 | ColumnequipmentBoardLastChangeTime | read-only | current | The time when the operational state of the board entry was last changed. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.14 | ColumnequipmentBoardRowStatus | read-create | current | SNMP administrivia. Manages creation and deletion of conceptual rows. See also SNMPv2-TC. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.15 | ColumnequipmentBoardMissing | read-only | current | There is no board present in a slot where the expected board type is defined. Suppressed if administrative status is down. A(ctivation): Card out of place (COP… |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.16 | ColumnequipmentBoardUnexpectedType | read-only | current | A type of board not matching the expected type is present and active in the same slot. Since the default value for the type is 'undefined' this alarm is raised… |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.17 | ColumnequipmentBoardTempHighExceeded | read-only | current | The threshold for environmental temperature on the board is exceeded. A: The temperature exceeds the associated threshold. D: Temperature is 0.5 degrees centig… |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.18 | ColumnequipmentBoardCommunicationFailure | read-only | current | Communication between the control unit and the the board has failed completely. A: There is a board present but there has been no communication established wit… |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.19 | ColumnequipmentBoardInterworkFailed | read-only | current | Communication between the control unit and the board has failed due to incompatible software. A: The control unit and the board have in-compatible software. D:… |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.20 | ColumnequipmentBoardSecondaryPowerFailed | read-only | current | Secondary DC power (1.8 or 2.5 V) failure. A: The secondary DC power on the board has failed. D: The secondary DC power is present. Note: If primary power fail… |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.21 | ColumnequipmentBoardVitalDataMissing | read-only | current | Product data vital for the safe operation of the equipment is missing. A: Product data missing. D: Product data present. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.22 | ColumnequipmentBoardNonVitalDataMissing | read-only | current | Administrative product data is missing. A: Product data missing. D: Product data present. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.23 | ColumnequipmentBoardUnderMaintenance | read-only | current | The board is undergoing maintenance, adminStatus is set to service. A: AdminStatus is set to service. D: AdminStatus is set to another value. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.24 | ColumnequipmentBoardTempThreshold | read-write | current | The threshold for temperature alarm on the board in 0.1 degrees centigrade. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.25 | ColumnequipmentBoardSwVersionMismatch | read-only | current | The version of the board SW does not match the SW version running och the main CU. For versions to match, the release number, e.g. 'r2b', must be the same. The… |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.26 | ColumnequipmentBoardObjectProperty | read-only | current | Property mask. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.27 | ColumnequipmentBoardTempLow | read-only | current | The low threshold for environmental temperature on the board is exceeded. A: The temperature exceeds the associated low threshold. D: Temperature is 0.5 degree… |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.28 | ColumnequipmentBoardTempVeryHigh | read-only | current | The very high threshold for environmental temperature on the board is exceeded. A: The temperature exceeds the associated threshold. D: Temperature is 0.5 degr… |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.29 | ColumnequipmentBoardReconfigure | read-only | current | Applicable for cu, cu2osc, cuSfp, cuSfpii and voa8chii. Reconfigure cu or cu2osc board to cuSfp. Reconfigure cu2osc or cuSfp board to cuSfpii. Reconfigure olde… |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.30 | ColumnequipmentBoardLedStatus | read-only | current | LED status for the board. This is primarily intended for debugging |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.31 | ColumnequipmentBoardModuleInfo | read-only | current | Information (for example firmware and serial number) about the module. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.32 | ColumnequipmentBoardNewSwActivatedButNotRestarted | read-only | current | A new SW version on the board has been activated, but the board has not been rebooted. This means that after the next reboot, a new SW will be active. For the … |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.33 | ColumnequipmentBoardLowTemperature | read-only | current | The environmental temperature on the board is below startuptemperature (+3 centigrade). A: The temperature is below +3 degrees centigrade. D: Temperature has i… |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.34 | ColumnequipmentBoardTempLowThreshold | read-only | current | The threshold for low temperature alarm on the board in 0.1 degrees centigrade. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.35 | ColumnequipmentBoardAdditionalInfo | read-only | current | Additional information about the board, e.g. FPGA revision. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.36 | ColumnequipmentBoardBootError | read-only | current | The card fails to boot. A: The card fails to boot. D: The card boot successfully. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.37 | ColumnequipmentBoardHardwareError | read-only | current | A hardware error occured. A: A hardware error occured. D: No hardware error. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.38 | ColumnequipmentBoardLowDiskSpace | read-only | current | Low disk space in the board. A: Not enough disk space. D: Disk space is enough. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.39 | ColumnequipmentBoardClockDrift | read-only | current | Clock frequency is out of range. A: Clock frequency out is out of range. D: Clock frequency is in range. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.40 | ColumnequipmentBoardPostponeFwUpgrade | read-write | current | Postpone activation of new traffic firmware when the board software is upgraded next time. If no firmware changes are available when upgrading this option will… |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.41 | ColumnequipmentBoardActivatePendingFwCommand | read-only | current | Command to activate a pending firmware upgrade. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.42 | ColumnequipmentBoardFwActivationPending | read-only | current | Firmware activation has been postponed in a previous software upgrade. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.43 | ColumnequipmentBoardFeatureNotSupported | read-only | current | A configuration request has failed since the chosen feature is not supported by the active firmware. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.44 | ColumnequipmentBoardFwReloadNeeded | read-only | current | The traffic HW has been programmed by a version of the system that does not offer a supported upgrade path to the currently running version. This typically hap… |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.45 | ColumnequipmentBoardFwContextUnknown | read-only | current | The running version of the SW cannot recover the settings of the traffic HW/FW. The state of the traffic HW is unknown. A reset of the traffic unit is recommen… |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.46 | ColumnequipmentBoardBoardVariant | read-write | current | Determines board configuration. dualMuxponderProt - 2x Muxponder with protection hexTransponder - 6x Transponder tripleMuxponderProt - 3x Muxponder with protec… |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.47 | ColumnequipmentBoardCabinetConnectivity | read-write | current | Monitor Cabinet status if enabled. Alarm is raised if connection is lost. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.48 | ColumnequipmentBoardCabinetConnectionFailure | read-only | current | Connection to the cabinet has failed. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.49 | ColumnequipmentBoardOperationalVariant | read-create | current | Operational Variant mode of board, Normal or OpenFlow Controlled. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.50 | ColumnequipmentBoardAid | read-only | current | The access identifier (AID) of the product. The format is according to GR-833. |
| 1.3.6.1.4.1.8708.2.11.2.3.1.1.51 | ColumnequipmentBoardPhysicalLocation | read-only | current | The Physical location of the product. The format is according to GR-833. |
| 1.3.6.1.4.1.8708.2.11.2.4 | NodeequipmentPowerList | |||
| 1.3.6.1.4.1.8708.2.11.2.4.1 | TableequipmentPowerTable | not-accessible | current | The list of power supplies. |
| 1.3.6.1.4.1.8708.2.11.2.4.1.1 | RowequipmentPowerEntry | not-accessible | current | An entry in the power supply list. |
| 1.3.6.1.4.1.8708.2.11.2.4.1.1.1 | ColumnequipmentPowerIndex | read-only | current | An arbitrary index assigned to each power module. |
| 1.3.6.1.4.1.8708.2.11.2.4.1.1.2 | ColumnequipmentPowerName | read-only | current | The name of the power module. For example 'pow:1:2'. |
| 1.3.6.1.4.1.8708.2.11.2.4.1.1.3 | ColumnequipmentPowerSubrack | read-only | current | The number of the subrack in which the power module is present. |
| 1.3.6.1.4.1.8708.2.11.2.4.1.1.4 | ColumnequipmentPowerSlot | read-only | current | The number of the slot in which the power module is present. |
| 1.3.6.1.4.1.8708.2.11.2.4.1.1.5 | ColumnequipmentPowerType | read-only | current | The the type of power module. ac - AC power supply (230V). dc - DC power supply (48V). |
| 1.3.6.1.4.1.8708.2.11.2.4.1.1.9 | ColumnequipmentPowerInvPhysIndexOrZero | read-only | current | The row in the invPhysTable for this power module. Set to 0 if not known. |
| 1.3.6.1.4.1.8708.2.11.2.4.1.1.10 | ColumnequipmentPowerAdminStatus | read-write | current | The administrative state of the power module. down - This power module is not monitored. Suppresses alarms. up - The power module is monitored. |
| 1.3.6.1.4.1.8708.2.11.2.4.1.1.11 | ColumnequipmentPowerOperStatus | read-only | current | The operational state of the power module. notPresent - The power module is not present. down - The module is not active or there are faults preventing it from… |
| 1.3.6.1.4.1.8708.2.11.2.4.1.1.12 | ColumnequipmentPowerRowStatus | read-write | current | Manages creation and deletion of conceptual rows. See also SNMPv2-TC. |
| 1.3.6.1.4.1.8708.2.11.2.4.1.1.13 | ColumnequipmentPowerACPowerFailed | read-only | obsolete | AC power supply failed (230 V). A(ctivation): Active HW indication. D(e-activation): Inactive HW indication. |
| 1.3.6.1.4.1.8708.2.11.2.4.1.1.14 | ColumnequipmentPowerDCPowerFailed | read-only | obsolete | DC power supply failed (48 V). A: Active HW indication. D: Inactive HW indication. |
| 1.3.6.1.4.1.8708.2.11.2.4.1.1.15 | ColumnequipmentPowerTemperatureHigh | read-only | current | The built-in temperature monitoring of the power module thinks it is too hot. A: Active HW indication. D: Inactive HW indication. |
| 1.3.6.1.4.1.8708.2.11.2.4.1.1.16 | ColumnequipmentPowerModuleMissing | read-only | current | The power module is not available. A: Active HW indication. D: Inactive HW indication. |
| 1.3.6.1.4.1.8708.2.11.2.4.1.1.17 | ColumnequipmentPowerObjectProperty | read-only | current | Property mask. |
| 1.3.6.1.4.1.8708.2.11.2.4.1.1.18 | ColumnequipmentPowerDCPowerFailedSeverity | read-write | current | The severity of DC Power failed alarm. |
| 1.3.6.1.4.1.8708.2.11.2.4.1.1.19 | ColumnequipmentPowerAid | read-only | current | The access identifier (AID) of the product. The format is according to GR-833. |
| 1.3.6.1.4.1.8708.2.11.2.4.1.1.20 | ColumnequipmentPowerPhysicalLocation | read-only | current | The Physical location of the product. The format is according to GR-833. |
| 1.3.6.1.4.1.8708.2.11.2.4.1.1.21 | ColumnequipmentPowerPowerFailed | read-only | current | Power supply failed. A: Active HW indication. D: Inactive HW indication. |
| 1.3.6.1.4.1.8708.2.11.2.5 | NodeequipmentFanList | |||
| 1.3.6.1.4.1.8708.2.11.2.5.1 | TableequipmentFanTable | not-accessible | current | The list of fan modules. |
| 1.3.6.1.4.1.8708.2.11.2.5.1.1 | RowequipmentFanEntry | not-accessible | current | An entry in the fan module list. |
| 1.3.6.1.4.1.8708.2.11.2.5.1.1.1 | ColumnequipmentFanIndex | read-only | current | An arbitrary index assigned to each fan module. |
| 1.3.6.1.4.1.8708.2.11.2.5.1.1.2 | ColumnequipmentFanName | read-only | current | The name of the fan module. For example 'fan:1:2', where the first number indicates the subrack and the second number the fan slot. |
| 1.3.6.1.4.1.8708.2.11.2.5.1.1.3 | ColumnequipmentFanSubrack | read-only | current | The number of the subrack in which the fan module is present. |
| 1.3.6.1.4.1.8708.2.11.2.5.1.1.4 | ColumnequipmentFanSlot | read-only | current | The number of the fan-slot in which the fan module is present. |
| 1.3.6.1.4.1.8708.2.11.2.5.1.1.5 | ColumnequipmentFanInvPhysIndexOrZero | read-only | current | The row in the invPhysTable for this fan module. Set to 0 if not known. |
| 1.3.6.1.4.1.8708.2.11.2.5.1.1.6 | ColumnequipmentFanAdminStatus | read-write | current | The administrative state of the fan module. down - This fan module should not be monitored. Suppresses alarms. Useful if a subrack has only one fan for some re… |
| 1.3.6.1.4.1.8708.2.11.2.5.1.1.7 | ColumnequipmentFanOperStatus | read-only | current | The operational state of the fan module. Note: It is not possible to distinguish between a missing fan and a failed fan. Therefore 'notPresent' is currently no… |
| 1.3.6.1.4.1.8708.2.11.2.5.1.1.8 | ColumnequipmentFanRowStatus | read-write | current | Manages creation and deletion of conceptual rows. See also SNMPv2-TC. |
| 1.3.6.1.4.1.8708.2.11.2.5.1.1.9 | ColumnequipmentFanUnitFailed | read-only | current | The fan module has failed or is absent. A(ctivation): Active HW indication. D(e-activation): Inactive HW indication. |
| 1.3.6.1.4.1.8708.2.11.2.5.1.1.10 | ColumnequipmentFanMainUnitFailed | read-only | current | The main fan module has failed or is absent. A(ctivation): Active HW indication. D(e-activation): Inactive HW indication. |
| 1.3.6.1.4.1.8708.2.11.2.5.1.1.11 | ColumnequipmentFanObjectProperty | read-only | current | Property mask. |
| 1.3.6.1.4.1.8708.2.11.2.5.1.1.12 | ColumnequipmentFanFanFault | read-only | current | The Fan malfunction or fan speed differs from the set speed. A(ctivation): Active HW indication. D(e-activation): Inactive HW indication. |
| 1.3.6.1.4.1.8708.2.11.2.5.1.1.13 | ColumnequipmentFanAid | read-only | current | The access identifier (AID) of the product. The format is according to GR-833. |
| 1.3.6.1.4.1.8708.2.11.2.5.1.1.14 | ColumnequipmentFanPhysicalLocation | read-only | current | The Physical location of the product. The format is according to GR-833. |
| 1.3.6.1.4.1.8708.2.11.2.6 | NodelumentisEquipmentNotifications | |||
| 1.3.6.1.4.1.8708.2.11.2.6.0 | NodeequipmentNotifyPrefix | |||
| 1.3.6.1.4.1.8708.2.11.2.6.0.1 | NotificationequipmentBoardRowStatusActive | current | Sent when a board is added to the configuration. | |
| 1.3.6.1.4.1.8708.2.11.2.6.0.2 | NotificationequipmentBoardRowStatusDestroy | deprecated | Sent when a board is removed from the configuration. | |
| 1.3.6.1.4.1.8708.2.11.2.6.0.3 | NotificationequipmentBoardRowStatusInserted | current | Sent when a board is physically inserted. | |
| 1.3.6.1.4.1.8708.2.11.2.6.0.4 | NotificationequipmentBoardRowStatusRemoved | current | Sent when a board is physically removed. | |
| 1.3.6.1.4.1.8708.2.11.2.6.0.5 | NotificationequipmentBoardRowStatusDeleted | current | Sent when a board is deleted from the configuration. | |
| 1.3.6.1.4.1.8708.2.11.2.7 | NodeequipmentNode | |||
| 1.3.6.1.4.1.8708.2.11.2.7.1 | ScalarequipmentNodeLedTest | read-write | current | LED test for the network element. off - Normal operation. on - Light all leds. |
| 1.3.6.1.4.1.8708.2.11.2.7.2 | ScalarequipmentNodeIcnRedundancyMode | read-write | current | Indicates whether the internal communication network between sub-racks, ICN3 and ICN4, can be connected in a redundant manner or not. disabled - Non-redundant … |
| 1.3.6.1.4.1.8708.2.11.2.7.3 | ScalarequipmentNodeMemoryProfile | read-only | current | Indicates whether memory profilation shall be done or not. disabled - No memory profile enabled - Memory profile done |
| 1.3.6.1.4.1.8708.2.11.2.7.4 | ScalarequipmentAllowDummyPassiveSlots | read-write | current | This option is applicable for TM-3000 subracks only. Normally passive boards can only be created in slots 13-22. Enabling this options allows the user to creat… |
| 1.3.6.1.4.1.8708.2.11.2.7.5 | ScalarequipmentNodeManagementVlan | read-write | current | Indicates if VLAN is available (via DCN for nodes with cu) or not. off - No bridging of VLAN. (mgmtVlan off in node) bridge2dcn - VLAN is bridged to DCN. (mgmt… |
| 1.3.6.1.4.1.8708.2.11.2.7.6 | ScalarequipmentNodeMgmtVlanPrivacy | read-write | current | Set Mgmt Vlan privacy. Setting is for main subrack in node. Boards affected (in R14.0) is gbeMxp10GFEC, msMxp10G, gbe10Emxp10G and gbe22Emxp10G. isolated - pri… |
| 1.3.6.1.4.1.8708.2.11.2.7.7 | ScalarequipmentNodeDcnRedundancyMode | read-write | current | Indicates whether the DCN ports on a CU, DCN1 and DCN2, can be connected in a redundant manner or not. disabled - Non-redundant DCN connection. Both DCN ports … |
| 1.3.6.1.4.1.8708.2.11.2.7.8 | ScalarequipmentNodeProxyArp | read-write | current | Indicates if the Proxy ARP functionality is used. Using Proxy ARP simplifies the IP-address allocation and minimizes the use of different subnets in the networ… |
| 1.3.6.1.4.1.8708.2.11.2.8 | NodeequipmentResource | |||
| 1.3.6.1.4.1.8708.2.11.2.8.1 | ScalarequipmentResourceNumberOfBoards | read-only | current | The number of boards, active and passive, currently in use in this system |
| 1.3.6.1.4.1.8708.2.11.2.8.2 | ScalarequipmentResourceMaxNumberOfBoards | read-only | current | The maximum number of boards, active and passive, that is supported by the embedded software of this system |
| 1.3.6.1.4.1.8708.2.11.2.8.3 | ScalarequipmentResourceNumberOfActiveBoards | read-only | current | The number of active boards running on this system |
| 1.3.6.1.4.1.8708.2.11.2.8.4 | ScalarequipmentResourceMaxNumberOfActiveBoards | read-only | current | The maximum number of active boards that is supported by the embedded software of this system. |
| 1.3.6.1.4.1.8708.2.11.2.9 | NodeequipmentSlot | |||
| 1.3.6.1.4.1.8708.2.11.2.9.1 | TableequipmentSlotTable | not-accessible | current | The slot list. |
| 1.3.6.1.4.1.8708.2.11.2.9.1.1 | RowequipmentSlotEntry | not-accessible | current | An entry in the slot list. One entry for each slot. |
| 1.3.6.1.4.1.8708.2.11.2.9.1.1.1 | ColumnequipmentSlotIndex | read-only | current | An arbitrary index assigned to each slot entry. |
| 1.3.6.1.4.1.8708.2.11.2.9.1.1.2 | ColumnequipmentSlotName | read-only | current | The name of the slot, for example 'tpmr2500:1:2' where the first number indicates in which sub-rack the slot is present and the second number in which slot. |
| 1.3.6.1.4.1.8708.2.11.2.9.1.1.3 | ColumnequipmentSlotSubrack | read-only | current | The number of the subrack in which the slot is present. |
| 1.3.6.1.4.1.8708.2.11.2.9.1.1.4 | ColumnequipmentSlotSlot | read-only | current | The slot number. |
| 1.3.6.1.4.1.8708.2.11.2.9.1.1.5 | ColumnequipmentSlotAdminStatus | read-write | current | The administrative state of the slot. down - The slot is not monitored. up - The interface should be activated. |
| 1.3.6.1.4.1.8708.2.11.2.9.1.1.6 | ColumnequipmentSlotUsageState | read-only | current | Tells if the slot is used or not. used - Slot is used. notUsed - Slot is not used. |
| 1.3.6.1.4.1.8708.2.11.2.9.1.1.7 | ColumnequipmentSlotEmptySlot | read-only | current | Slot is empty, alarm only applicable for systems with mendatory slot usage A: Slot is empty. D: No empty slot. |
| 1.3.6.1.4.1.8708.2.11.2.9.1.1.8 | ColumnequipmentSlotEquipped | read-only | current | Is the entity equipped. |
| 1.3.6.1.4.1.8708.2.11.2.9.1.1.9 | ColumnequipmentSlotAid | read-only | current | The access identifier (AID) of the slot. The format is according to GR-833. |
| 1.3.6.1.4.1.8708.2.11.2.9.1.1.10 | ColumnequipmentSlotPhysicalLocation | read-only | current | The physical location of the slot. The format is according to GR-833. |
| 1.3.6.1.4.1.8708.2.11.2.10 | NodeequipmentOpticalModuleList | |||
| 1.3.6.1.4.1.8708.2.11.2.10.1 | TableequipmentOpticalModuleTable | not-accessible | current | The module list. |
| 1.3.6.1.4.1.8708.2.11.2.10.1.1 | RowequipmentOpticalModuleEntry | not-accessible | current | An entry in the module list. |
| 1.3.6.1.4.1.8708.2.11.2.10.1.1.1 | ColumnequipmentOpticalModuleIndex | read-only | current | An arbitrary index assigned to each entry. |
| 1.3.6.1.4.1.8708.2.11.2.10.1.1.2 | ColumnequipmentOpticalModuleHostBoardType | read-only | current | The actual board type hosting the optical module. |
| 1.3.6.1.4.1.8708.2.11.2.10.1.1.3 | ColumnequipmentOpticalModuleType | read-only | current | The type of optical module, for example monitor, switch, wss, amp etc |
| 1.3.6.1.4.1.8708.2.11.2.10.1.1.4 | ColumnequipmentOpticalModuleName | read-only | current | The management name of the interface, for example 'module:[HostBoardType]:[ moduleType]:[subrack]:[slot]'. |
| 1.3.6.1.4.1.8708.2.11.2.10.1.1.5 | ColumnequipmentOpticalModuleSubrack | read-only | current | The number of the subrack where the module is located. |
| 1.3.6.1.4.1.8708.2.11.2.10.1.1.6 | ColumnequipmentOpticalModuleSlot | read-only | current | The number of the slot where the module is located. |
| 1.3.6.1.4.1.8708.2.11.2.10.1.1.7 | ColumnequipmentOpticalModuleFirmwareVersion | read-only | current | Firmware version of the module. |
| 1.3.6.1.4.1.8708.2.11.2.10.1.1.8 | ColumnequipmentOpticalModuleSerialNumber | read-only | current | Serial number of the module. |
| 1.3.6.1.4.1.8708.2.11.2.10.1.1.9 | ColumnequipmentOpticalModuleWarmingUpState | read-only | current | Module is warming up, the optics has not reached a stable state. True: Module is warming up. False: Module is ready and optics have reached stable state. |
| 1.3.6.1.4.1.8708.2.11.2.10.1.1.10 | ColumnequipmentOpticalModuleFailure | read-only | current | The module is experiencing a failure. A(ctivation): The module has failed D(e-activation): The module is OK again |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| EquipmentBoardType | INTEGER { undefined (0), cu (1), tpMr2500 (2), oxc8 (3), oxc16 (4), ocu2 (5), mxp028 (6), ad1AB (7), ad1BA (8), ad2AB (9), ad2BA (10), ad4AB (11), ad4BA (12), tpDGbE (13), oa (14), mdu8Ext (15), mdu8Term (16), ocu4 (17), mxp004 (18), ad2oaAB (19), ad2oaBA (20), oa2 (21), adcwdm (22), ad1spr (23), tp10G (24), tpLMr2500 (25), cu1osc (26), cu2osc (27), obu (28), sync2Mhz (29), mxp8 (30), mxp16 (31), tpDGbED (32), tpDGbEC (33), tpDFcD (34), tpDFcC (35), tpFcGbED (36), tpFcGbEC (37), tpTFcD (38), tpQMr (39), mdu4TermAB (40), mdu4TermBA (41), ad1cwdm (42), ad2cwdm (43), tp10GLAN (44), tp10GRC (45), escon8 (46), oa1x15dBm (47), oa2x15dBm (48), gxp2500 (49), gxp2500Sfp (50), gxp10G (51), tpDGbEDv2 (52), tpDGbESfp (53), tpDFcDv2 (54), tpDFcSfp (55), ad2x1cwdm (56), ad2x2cwdm (57), mdu8Term2 (58), tpDDGbE (59), fpuOas2824 (60), mu2F8C (61), du2F8C (62), tpD10GL (63), tpDDGbER (64), tp10GBu (65), tp10GLANBu (66), tp10GClBu (67), tp10GLANClBu (68), mdu8EvenExt (69), mdu8EvenTerm (70), oapre1x17dBm (71), oa2x17dBm (72), oiuc100200 (73), oapow1x17dBm (74), oa1x17dBm (75), gbe9Mxp10G (76), ad1dwdm2F (77), ad1cwdm2F (78), mdu4Ext2F (79), mdu4Term2F (80), voa8ch (81), oa1x20dBm (82), oa2x20dBm (83), fpuYm235 (84), ad4dwdm2F (85), tpQMri (86), oar450c (87), cuSfp (88), tpMr25v2 (89), tpD10GbE (90), tpD10GbER (91), mdu4ExtAB (92), mdu4ExtBA (93), oiuc50100 (94), mROADM1P800 (95), edu6pGbE (96), tp10GClTc (97), mxp4x2G5 (98), oa1xLG20dBm (99), oa2xLG20dBm (100), oa1xFG10dBm (101), oa2xFG10dBm (102), tp10GOtnTc (103), mdu40Even (104), mdu40Odd (105), mdu8Ee (106), mdu8Eo (107), ocm2p (108), msMxp (109), voa8chii (110), msMxpR (111), msMxpDQgbe (112), tp10GTcEr (113), gbe10Emxp10G (114), edu12pGbE (115), gbeMxp10GFEC (116), roadm1x4G100 (117), dQgbeMxpR (118), tpQMS (119), tpQMSR (120), gbe22Emxp10G (121), oa1x26dBm(122), pcu2p (123), mxp4x2G5Oc (124), voa2ch (125), msMxp10GTCEr (126), msMxp10G (127), msMxpQMS2G5 (128), gbe22Emxp10Gii (129), bsu1x5Even (130), bsu1x5Odd (131), gbe10Emxp10Gii (132), mba1 (133), mba1SonetDeprecated (134), mba2 (135), mba2SonetDeprecated (136), mxpmbh1Sdh (137), mxpmbh1Sonet (138), roadm1x8G50 (139), ad4Even50 (140), ad4Odd50 (141), emxp80Gii (142), msMxpQMS2G5R (143), mxp8iiSdh (144), mxp8iiSonet (145), mba2E (146), mba2ptpSdh (147), mba2ptpSonet (148), mba2EptpSdh (149), mba2EptpSonet (150), mdu40EvenL (151), mdu40OddL (152), oa1x20dBmVg (153), oa2x20dBmVg (154), roadm1x2G100 (155), roadm1x2G50 (156), tpq10Gfec (157), cuSfpii (158), coD40ev (159), coD40eve (160), coD40od (161), coD40ode (162), dcDk652km20 (163), dcDk652km40 (164), dcDk652km60 (165), dcDk652km80 (166), dcP652km40 (167), dcP652km60 (168), dcP652km80 (169), dcP652km100 (170), dcP652km120 (171), emxp40Gii (172), tpqmp (173), tpq10GfecReg (174), mdu16cl50g (175), voa8chsfp (176), msTp40G (177), msMxp40G(178), mxp10gotn (179), emxp62iie (180), emxp120iie (181), ocudq (182), tm4700 (183), tm4011 (184), tm100mxp (185), tm100tp (186), tm100reg (187), ocuseed2p (188), oa2x21seed (189), oypatchcord (190), tpq10gfeci (191), tpq10gfecregi (192), tphex10gotn (193), emxp48iie (194), tp100gotn (195), emxp220iie (196), tpmrHL16G (197), fhmxp10g (198), mxp100gotn (199), cuSfpiii (200), emxp240iie (201), tpmrHL16GUni (202), fpu1 (203), oaraed21hghyb (204), oaraed21hgind (205), emxp3 (206), dcDk652km100 (207), dcDk652km120 (208), dcP652km20 (209), fhau1(210), fha1u1(211), oa1x20dBmVg2 (212), oa2x20dBmVg2 (213), ptio10g (214), fxp400gotn (215), compo24 (216), rfu1 (217), coD919926 (218), coD927934 (219), coD935942 (220), coD943950 (221), coD951958 (222), coD919926e (223), coD927934e (224), coD935942e (225), coD943950e (226), coD951958e (227), co4 (228), co5 (229), codsf20eva (230), codsf20evb (231), codsf4919 (232), codsf4926 (233), codsf4927 (234), codsf4934 (235), codsf4935 (236), codsf4942 (237), codsf4943 (238), codsf4950 (239), codsf4951 (240), codsf4958 (241), codsf2919 (242), codsf2922 (243), codsf2923 (244), codsf2926 (245), codsf2927 (246), codsf2930 (247), codsf2931 (248), codsf2934 (249), codsf2935 (250), codsf2938 (251), codsf2939 (252), codsf2942 (253), codsf2943 (254), codsf2946 (255), codsf2947 (256), codsf2950 (257), codsf2951 (258), codsf2954 (259), codsf2955 (260), codsf2958 (261), tp100gotnii (262), roadm1x4f (263), ptio100g (264), oadm2ch (265), emxp1u(266), emxp1us(267), mxp200gotn (268), emxp440 (269), oaraed20lghyb (270), roadm1x9f (271), ocm8p (272), ad1c2fotdr (273), hdea1600 (274), oa1xLG20dBmb (275), oa2xLG20dBmb (276), oa1x20dBmVgb (277), oa2x20dBmVgb (278), codsf24mpo10104 (279), otdr8p (280), coD48ev (281), coD48od (282), emxp440q (283), oa1x21dBmVgEC (284), oa2x21dBmVgEC (285), co10 (286), emxp800xh (287), coocuD4x4 (288), coocuD4x8 (289), cooiuc50100 (290), co2xOTDR1611 (291), coD4919 (292), coD4923 (293), coD4927 (294), coD4931 (295), coD4935 (296), coD4939 (297), coD4943 (298), coD4947 (299), coD4951 (300), coD4955 (301), tgCo4 (1001), tgCo5 (1005), tgCo6 (1006), tgCo7 (1007), tgCo8 (1008), tgCo9 (1009), tgCo10 (1010), tgCo11 (1011), tgCo12 (1012), tgCo14 (1014), tgCo15 (1015), tgCo16 (1016), tgCoDxxxyyy (1040), tgCoD40ev (1041), tgCoD40eve (1042), tgCoD40od (1043), tgCoD40ode (1044), tgCoBSU1x5ev (1050), tgCoBSU1x5od (1051), tgCad86XX04 (1055), tgCad86XX02 (1056), tgCoDSF2ch9XXAB (1057), tgCoDSF4ch9XXAB (1058), tgCoDSF2ch9XXBA (1059), tgCoDSF4ch9XXBA (1060), tgTcosf2x1b (1061), tgTcosf2x1d (1062), tgCoD4XXX (1070), tgCoDSF20 (1080), tgCoDSF20evA (1081), tgCoDSF20evB (1082), tgCoDSF20odA (1083), tgCoDSF20odB (1084), tgCoSFBSU1x5ev (1085), tgTco12 (2012), tgTco14 (2014), acd2pGbE (10000), acd5pGbE (10001), acd10G (10002), edu5GT (10003), edu10GLT (10004), edu10GLTS (10005), nidGE (20000), nidSfp155 (20001), nidSfp622 (20002), nidSfpVc12 (20003), nidSfp2488 (20004), ts1100EthMux4p (220401), ts1100OPU (250101), ts1100OPUDouble (250201), ts1100PreAmpDouble (260401), ts1100PreAmp (261001), ts1100AttenuatorDouble (270001), ts1100UnivAggDGbE (540001), ts1100UnivAggDFC (540002), ts1100UnivAggDGbE2 (540003), ts1100UnivAgg (550000), ts1100UnivAgg4xGbE (580000), ts1100UnivAgg2xDGbE (5800002), ts1100UnivAgg3xGbERep (5800003), ts1100UnivAgg3x25GRep (5800004), ts1100UnivAgg2xGbE2xSTM (581000), ts1100UnivAgg4xGbE2 (5810002), ts1100UnivAgg3xGbERep2 (5810003), ts1100Muxponder10G (590000), ts1100Muxponder10G2 (5900002), ts1100Nmb (600100), ts1100Nmb6003 (600300), ts1100Tp2x4GFC (740001), ts1100Conv1250Cwdm (750000), ts1100Conv2500Cwdm (760000), ts1100Tp2500Cwdm1 (770000), ts1100Tp2x2500Cwdm1 (772000), ts1100Tp10G (790000), ts1100Tp10G7910 (791000), ts1100Tp10G7910Rep (7910002), ts1100DuplexerDouble (802001), ts1100MuxDemux4chPizza (803000), ts1100MuxDemux4chExtPizza (803100), ts1100MuxDemux8chPizza (803200), ts1100MuxDemux8chExtPizza (803300), ts1100Duplexer (812001), ts1100MuxDemux4ch1t4 (813001), ts1100MuxDemux4p1ch1t4 (813101), ts1100MuxDemux8ch (813200), ts1100MuxDemux8p1ch (813300), ts1100MuxDemux8ch2 (813400), ts1100MuxDemux4ch5t8 (814001), ts1100MuxDemux4p1ch5t8 (814101), ts1100MuxDemux4chBidir (823000), ts1100AddDropDouble (850100), ts1100AddDrop (870101), ts1100AddDropSingle (870102), ts1100DWDMMuxDemuxExt (883001), ts1100DWDMMuxDemux (883101), ts1100Power9000Supply (900000), ts1100Power9048Supply (904800), ts1100Power9122Supply (912200), ts1100Power9148Supply (914800), ts1100Power9220Supply (922000), tm206Fan (9200201), tm206OSC1 (9221001), tm206OSC2 (9221002), tm206TAM4xesc (9500101), tm206TAMln4xesc (9510101), tm206TAMln4xetr (9510201), tm206TAMlnFlex (9510301), tm206TAMln2xfc (9510401), tm206TAMlnp2xfc (9510501), tm206Cu (9600201), tm206Cu2 (9600202), tm206tp2x4gfc (9780001), tm206MuxDemux4ch1t4 (9813001), tm206MuxDemux4p1ch1t4 (9813101), tm206MuxDemux4ch5t8 (9814001), tm206MuxDemux4p1ch5t8 (9814101), tm206MuxDemux4chBidir1 (9823001), tm206MuxDemux4chBidir2 (9823002), tm206AddDrop (9870101) } | current | The functional type of the board. At least one type is defined for each combination of the following properties of the board: 1 - number of interfaces 2 - type of interfaces 3 - the functionality of the board (can usual… |
| EquipmentSubrackType | INTEGER { undefined (0), tm300 (1), tm3000 (2), tm301 (3), tm101 (4), tm101p (5), aux (6), tm102 (7), mba1 (8), mba2 (9), mba2E (10), tm102pas (11), tm102pas3 (12), tm3000ii (13), tm2000 (14), tm301ii (15), tmFha1UDc1 (16), tmRfuAc1 (17), tmEmxp1UDc (18), tmHdea1600Dc (19), tm3000iie (20), tmEmxpXh800Dc (21), ts1100Subrack2Slots (9002), tm206Subrack6Slots (9006), ts1100Subrack8Slots (9011), ts1100Subrack12Slots (9013) } | current | The type of subrack: tm300 - The small subrack (old). tm3000 - The big subrack. tm3000ii - The big subrack, enhanced version. tm3000iie - The big subrack, enhanced second version. tm301 - The small subrack (new). tm301i… |
| FirstPbSlot | INTEGER { undefined(0), slot3(3), slot4(4), slot13(13) } | current | A value indicating the first slot where it is possible to configure a passive board in a subrack. undefined - indicates that no value has yet been set. slot3 - Slot 3 is the first passive slot. slot4 - Slot 4 is the fir… |