MIB Viewer

LUM-OCM-MIB

76 objects
The optical control interface MIB. - General - Monitor interfaces Note that, every time a get operation is performed and both ports are set to admin status up, the switch will switch to update both ports. (unless commissioning mode) The guaranteed durability of switching is 10 million times. That means, if you switch (perform a get operation) more than every 50 second, product lifetime of 15 years can not be guaranteed.
Imported Objects
LUM-REGlumModules lumOcmMIB
LUM-TC MISSINGBoardOrInterfaceAdminStatus BoardOrInterfaceOperStatus CommandString FaultStatus LambdaFrequency MgmtNameString PortNumber SlotNumber SubrackNumber
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMIInteger32 MODULE-IDENTITY OBJECT-TYPE Unsigned32
SNMPv2-TCDateAndTime DisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.8708.1.1.33IdentitylumOcmMIBModuleThe optical control interface MIB. - General - Monitor interfaces Note that, every time a get operation is performed and both ports are set to admin status up,…
1.3.6.1.4.1.8708.2.33.1NodelumOcmConfs
1.3.6.1.4.1.8708.2.33.1.1NodelumOcmGroups
1.3.6.1.4.1.8708.2.33.1.1.1GroupocmGeneralGroupcurrentThe general objects.
1.3.6.1.4.1.8708.2.33.1.1.2GroupocmIfGroupdeprecatedThe ocm interface objects.
1.3.6.1.4.1.8708.2.33.1.1.3GroupocmChannelGroupdeprecatedThe ocm channel objects.
1.3.6.1.4.1.8708.2.33.1.1.4GroupocmIfGroupV2deprecatedThe ocm interface objects.
1.3.6.1.4.1.8708.2.33.1.1.5GroupocmIfGroupV3deprecatedThe ocm interface objects.
1.3.6.1.4.1.8708.2.33.1.1.6GroupocmChannelGroupV2currentThe ocm channel objects.
1.3.6.1.4.1.8708.2.33.1.1.7GroupocmIfGroupV4currentThe ocm interface objects.
1.3.6.1.4.1.8708.2.33.1.2NodelumOcmCompl
1.3.6.1.4.1.8708.2.33.1.2.1CompliancelumOcmBasicComplV1deprecatedBasic implementation requirements for the OCM MIB V1.
1.3.6.1.4.1.8708.2.33.1.2.2CompliancelumOcmBasicComplV2deprecatedBasic implementation requirements for the OCM MIB V2 (14.0).
1.3.6.1.4.1.8708.2.33.1.2.3CompliancelumOcmBasicComplV3deprecatedBasic implementation requirements for the OCM MIB V2 (23.0).
1.3.6.1.4.1.8708.2.33.1.2.4CompliancelumOcmBasicComplV4deprecatedBasic implementation requirements for the OCM MIB V2 (30.0).
1.3.6.1.4.1.8708.2.33.1.2.5CompliancelumOcmBasicComplV5currentBasic implementation requirements for the OCM MIB V2 (31.0).
1.3.6.1.4.1.8708.2.33.1.3NodelumOcmMinimalGroups
1.3.6.1.4.1.8708.2.33.1.4NodelumOcmMinimalCompl
1.3.6.1.4.1.8708.2.33.1.4.1CompliancelumOcmMinimalComplV1currentMinimal implementation requirements for the OCM MIB V1.
1.3.6.1.4.1.8708.2.33.2NodelumOcmMIBObjects
1.3.6.1.4.1.8708.2.33.2.1NodeocmGeneral
1.3.6.1.4.1.8708.2.33.2.1.1ScalarocmGeneralLastChangeTimeread-onlycurrentThe time when the configuration of the MIB was last changed.
1.3.6.1.4.1.8708.2.33.2.1.2ScalarocmGeneralStateLastChangeTimeread-onlycurrentThe time when the state of the MIB was last changed.
1.3.6.1.4.1.8708.2.33.2.1.3ScalarocmGeneralOcmIfTableSizeread-onlycurrentSize of table
1.3.6.1.4.1.8708.2.33.2.1.4ScalarocmGeneralOcmChannelTableSizeread-onlycurrentSize of table
1.3.6.1.4.1.8708.2.33.2.2NodeocmIfList
1.3.6.1.4.1.8708.2.33.2.2.1TableocmIfTablenot-accessiblecurrentThe interface list.
1.3.6.1.4.1.8708.2.33.2.2.1.1RowocmIfEntrynot-accessiblecurrentAn entry in the interface list.
1.3.6.1.4.1.8708.2.33.2.2.1.1.1ColumnocmIfIndexread-onlycurrentAn arbitrary index assigned to each entry.
1.3.6.1.4.1.8708.2.33.2.2.1.1.2ColumnocmIfNameread-onlycurrentThe management name of the interface, for example 'ocm:1:2:1', where the first number indicates sub-rack, the second slot number and the third is the port numb…
1.3.6.1.4.1.8708.2.33.2.2.1.1.3ColumnocmIfDescrread-writecurrentUser configurable label.
1.3.6.1.4.1.8708.2.33.2.2.1.1.4ColumnocmIfSubrackread-createcurrentThe number of the subrack where the interface is located.
1.3.6.1.4.1.8708.2.33.2.2.1.1.5ColumnocmIfSlotread-createcurrentThe number of the slot where the interface is located.
1.3.6.1.4.1.8708.2.33.2.2.1.1.6ColumnocmIfRxPortread-createcurrentThe number of the port where the RX-side of the interface is located.
1.3.6.1.4.1.8708.2.33.2.2.1.1.7ColumnocmIfInvPhysIndexOrZeroread-onlycurrentThe row in the invPhysTable for this interface. Set to 0 if not known.
1.3.6.1.4.1.8708.2.33.2.2.1.1.8ColumnocmIfAdminStatusread-writecurrentThe administrative state for the interface. down - The interface should be inactive. service - The interface is activated but alarms are suppressed. Intended f…
1.3.6.1.4.1.8708.2.33.2.2.1.1.9ColumnocmIfOperStatusread-onlycurrentThe operational state for the interface. notPresent - The physical resources are not available. down - The interface is de-activated or the are faults preventi…
1.3.6.1.4.1.8708.2.33.2.2.1.1.12ColumnocmIfPowerThresholdread-createcurrentThe threshold for power levels. If the measured power level is below the threshold, it is regarded as no signal. For OCM8p: Default -13dBm Range -35 to 100dBm …
1.3.6.1.4.1.8708.2.33.2.2.1.1.13ColumnocmIfUpdateLastChangeTimeread-onlycurrentThe time when the last measurement was done.
1.3.6.1.4.1.8708.2.33.2.2.1.1.14ColumnocmIfConnectedSubrackread-createcurrentThe number of the subrack where the connected interface is located. (0 is not valid)
1.3.6.1.4.1.8708.2.33.2.2.1.1.15ColumnocmIfConnectedSlotread-createcurrentThe number of the slot where the connected interface is located. (not possible to set 0, 1, 19-22, oa/roadm can not be placed in those slots)
1.3.6.1.4.1.8708.2.33.2.2.1.1.16ColumnocmIfConnectedPortread-createcurrentThe number of the connected port. (the tx port number). 1 or 3 for OA, 5 for 1x2ROADM/100G/50G, 9 for 1x4ROADM/100G,ROADM1x4f, 17 for 1x8ROADM/50G, 19 for ROAD…
1.3.6.1.4.1.8708.2.33.2.2.1.1.17ColumnocmIfActivePortread-onlycurrentThe number of the active port. Only valid when commissioning mode.
1.3.6.1.4.1.8708.2.33.2.2.1.1.18ColumnocmIfControlModeread-onlycurrentWhat mode the ocm is in. normal - the switch toggle every hour and measure both ports. commissioning - the switch is set to one active port and measurement is …
1.3.6.1.4.1.8708.2.33.2.2.1.1.21ColumnocmIfReferenceTimeread-createcurrentTime where reference values were saved.
1.3.6.1.4.1.8708.2.33.2.2.1.1.22ColumnocmIfSwitchFailureread-onlycurrentSwitch failure. A: The switch is stuck and it is not possible to change port. It is not sure if it the values comes from the expected port. D: The switch works…
1.3.6.1.4.1.8708.2.33.2.2.1.1.23ColumnocmIfDataSourceNotDefinedread-onlycurrentData source not defined, A: No connected slot, connected subrack nor connected port is defined. D: Connected slot, connected subrack and connected port is ok.
1.3.6.1.4.1.8708.2.33.2.2.1.1.24ColumnocmIfCommissioningModeread-onlycurrentData source not defined, A: Commissioning mode is used D: Normal mode
1.3.6.1.4.1.8708.2.33.2.2.1.1.25ColumnocmIfModuleFailureread-onlycurrentThe module HW has detected a failure. A: The module has failed D: The module is OK again
1.3.6.1.4.1.8708.2.33.2.2.1.1.26ColumnocmIfConfigurationCommandread-onlycurrentSelect which control mode to use. normal - the switch toggle every hour and measure both ports. commissioning - the switch is set to one port while adjusting s…
1.3.6.1.4.1.8708.2.33.2.2.1.1.27ColumnocmIfChangeConnectedPortread-onlycurrentSelect which monitor port that is connected to this ocm port.
1.3.6.1.4.1.8708.2.33.2.2.1.1.28ColumnocmIfSaveReferenceread-onlycurrentSave current measurement as reference values
1.3.6.1.4.1.8708.2.33.2.2.1.1.29ColumnocmIfPowerOffsetread-createcurrentAn offset value added to all power levels to get an accurate presentation of channel powers at the line port. Generally offset values depends upon board type c…
1.3.6.1.4.1.8708.2.33.2.2.1.1.30ColumnocmIfConnectedBoardTyperead-createcurrentWhat board type that is connected to the ocm. The power offset default value is changed based on the chosen board type. Please note that this function is not a…
1.3.6.1.4.1.8708.2.33.2.2.1.1.31ColumnocmIfChangeConnectedBoardTyperead-onlycurrentSelect board type for the monitor port connected to this ocm port.
1.3.6.1.4.1.8708.2.33.2.2.1.1.32ColumnocmIfMaxPowerLevelread-onlycurrentThe maximum received power level for this port in units of 0.1 dBm.
1.3.6.1.4.1.8708.2.33.2.2.1.1.33ColumnocmIfMinPowerLevelread-onlycurrentThe minimum received power level for this port in units of 0.1 dBm.
1.3.6.1.4.1.8708.2.33.2.2.1.1.34ColumnocmIfDeltaPowerread-onlycurrentThe difference between the maximum and the minimum received power level for this port in units of 0.1 dBm.
1.3.6.1.4.1.8708.2.33.2.2.1.1.35ColumnocmIfChangePowerThresholdread-onlycurrentSelect the power threshold for this ocm port. If the measured power level is below the threshold, it is regarded as no signal.
1.3.6.1.4.1.8708.2.33.2.2.1.1.36ColumnocmIfChangePowerOffsetread-onlycurrentSelect the power offset for this ocm port. The power offset is a value added to all power levels to get an accurate presentation of channel powers at the line …
1.3.6.1.4.1.8708.2.33.2.2.1.1.37ColumnocmIfPowerOffsetAdjustmentread-onlycurrentAn offset adjustment added to the power offset to mitigate the effects of differences between actual power measured at the OCM and the configured power offset …
1.3.6.1.4.1.8708.2.33.2.2.1.1.38ColumnocmIfSpacingModeread-createcurrentSpacing mode is configured for monitoring channel power with the channel spacing of 50GHz. spacing50GHz: interface with channels in 50 GHz intervals
1.3.6.1.4.1.8708.2.33.2.2.1.1.39ColumnocmIfHighInputPowerread-onlycurrentThe OCM module has detected a high input power. A: OCM module has dectected high input power (above 20dBm) on particular port. D: Optical input power is within…
1.3.6.1.4.1.8708.2.33.2.3NodeocmChannelList
1.3.6.1.4.1.8708.2.33.2.3.1TableocmChannelTablenot-accessiblecurrentThe channel list.
1.3.6.1.4.1.8708.2.33.2.3.1.1RowocmChannelEntrynot-accessiblecurrentAn entry in the channel list.
1.3.6.1.4.1.8708.2.33.2.3.1.1.1ColumnocmChannelIndexread-onlycurrentAn arbitrary index assigned to each entry.
1.3.6.1.4.1.8708.2.33.2.3.1.1.2ColumnocmChannelNameread-onlycurrentThe management name of the interface, for example 'ocm:1:2:1', where the first number indicates sub-rack, the second slot number and the third is the port numb…
1.3.6.1.4.1.8708.2.33.2.3.1.1.3ColumnocmChannelFrequencyread-createcurrentFreqency in hundreds of GHz (0.01 GHz).
1.3.6.1.4.1.8708.2.33.2.3.1.1.4ColumnocmChannelPowerLevelread-onlycurrentThe received power level in units of 0.1 dBm.
1.3.6.1.4.1.8708.2.33.2.3.1.1.5ColumnocmChannelUpdateLastChangeTimeread-onlycurrentTime when last measurement was done.
1.3.6.1.4.1.8708.2.33.2.3.1.1.6ColumnocmChannelOcmRefIfIndexread-onlycurrentThe SNMP-index of the OCM i/f object related to this object.
1.3.6.1.4.1.8708.2.33.2.3.1.1.7ColumnocmChannelReferencePowerLevelread-createcurrentThe reference power level in units of 0.1 dBm.
1.3.6.1.4.1.8708.2.33.2.3.1.1.8ColumnocmChannelReferenceTimeread-createcurrentTime where reference values were saved.
1.3.6.1.4.1.8708.2.33.2.3.1.1.9ColumnocmChannelSaveReferenceread-onlycurrentSave current measurement as reference values
1.3.6.1.4.1.8708.2.33.2.4NodelumentisOcmNotifications