MERITAGE-MIB
42 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.81.32 | Nodemeritage | |||
| 1.3.6.1.4.1.81.32.1 | NodemeritageBase | |||
| 1.3.6.1.4.1.81.32.1.1 | ScalarmeritageBaseLEDs | read-only | mandatory | Summary of the hub LEDs. The coding of each LED is defined in meritageLedColour Number of bits per LED, currently 8 (1st byte) Number of LEDs, currently 8 (2nd… |
| 1.3.6.1.4.1.81.32.1.2 | ScalarmeritageBaseTemperatureExceed | read-only | mandatory | Fault condition indicating that the temperature exceeded 70 degrees in at least one of the modules in the hub. |
| 1.3.6.1.4.1.81.32.1.3 | ScalarmeritageBaseXswitchConfiguration | read-only | mandatory | The value of this attribute shows whether the two horizontal Xswitches are connected internally to form a single 14-slots-wide Xswitch in the Meritage, or not. |
| 1.3.6.1.4.1.81.32.1.4 | ScalarmeritageBaseFaultMask | read-only | mandatory | Each bit of this item describes a fault situation in the Meritage hub. bit 1: meritageBaseFanActivityStatus.1 = failed (2), bit 2: meritageBaseFanActivityStatu… |
| 1.3.6.1.4.1.81.32.1.5 | TablemeritageBaseFanTable | not-accessible | mandatory | Table of attributes for Fan units in the Meritage. |
| 1.3.6.1.4.1.81.32.1.5.1 | RowmeritageBaseFanEntry | not-accessible | mandatory | An entry in the table, containing attributes for a single Fan unit in the Meritage. |
| 1.3.6.1.4.1.81.32.1.5.1.1 | ColumnmeritageBaseFanId | read-only | mandatory | Fan index for identifying the Fan in the Meritage 1-left, 2-right. |
| 1.3.6.1.4.1.81.32.1.5.1.2 | ColumnmeritageBaseFanActivityStatus | read-only | mandatory | This attribute defines the status of the Fan. |
| 1.3.6.1.4.1.81.32.1.6 | TablemeritageBasePSUTable | not-accessible | mandatory | Table of configuration attributes for the Power Supply Units. |
| 1.3.6.1.4.1.81.32.1.6.1 | RowmeritageBasePSUEntry | not-accessible | mandatory | An entry in the table, containing information for a single Power Supply Unit. |
| 1.3.6.1.4.1.81.32.1.6.1.1 | ColumnmeritageBasePSUId | read-only | mandatory | Index identifying the PSU.1-left, 2-middle, 3-right. |
| 1.3.6.1.4.1.81.32.1.6.1.2 | ColumnmeritageBasePSUType | read-only | mandatory | This attribute indicates the PSU type. |
| 1.3.6.1.4.1.81.32.1.6.1.3 | ColumnmeritageBasePSUHWVersion | read-only | mandatory | Hardware version of the PSU. Stored in ASCII format : first Byte - hardware major version number Second Byte - hardware minor version number (Configuration Sym… |
| 1.3.6.1.4.1.81.32.1.6.1.4 | ColumnmeritageBasePSURatedPower | read-only | mandatory | This attribute indicates the rated power of the PSU in Watts. |
| 1.3.6.1.4.1.81.32.1.6.1.5 | ColumnmeritageBasePSUActivityStatus | read-only | mandatory | This attribute defines the status of the PSU: active(1) - indicates that the PSU supplies power to the chassis. failed(2) - indicates PSU failure none(3) - ind… |
| 1.3.6.1.4.1.81.32.1.7 | ScalarmeritageBaseUpBckplnConfiguration | read-only | mandatory | Defines whether the Upper Backplane is constructed as a single domain (full), as a dual domain (split) or not installed. The hardware supports 2 bits for this … |
| 1.3.6.1.4.1.81.32.1.8 | ScalarmeritageBaseUpBckplnConfigurationSymbol | read-only | mandatory | Defines the Configuration Symbol of the Upper Backplane X.Y - where X & Y are integers: 1st byte (X) - Major version number 2nd byte - '.' 3rd byte (Y) - minor… |
| 1.3.6.1.4.1.81.32.2 | NodemeritageMSPV | |||
| 1.3.6.1.4.1.81.32.2.1 | ScalarmeritageMSPVBackupStatus | read-only | mandatory | This attribute defines the status of the backup M-SPV module in the Meritage: dormant (1) - indicates that the backup M-SPV is dormant and works ok. failed (2)… |
| 1.3.6.1.4.1.81.32.2.2 | ScalarmeritageMSPVMainPosition | read-only | mandatory | This attribute defines the position of the main M-SPV module in the Meritage: MSPV1 (1) - indicates that the main M-SPV is the one on the left slot MSPV2 (2) -… |
| 1.3.6.1.4.1.81.32.3 | NodemeritageGroup | |||
| 1.3.6.1.4.1.81.32.3.1 | TablemeritageGroupTable | not-accessible | mandatory | A table containing information about each group in the hub. |
| 1.3.6.1.4.1.81.32.3.1.1 | RowmeritageGroupEntry | not-accessible | mandatory | An entry containing information about a particular group in the hub. |
| 1.3.6.1.4.1.81.32.3.1.1.1 | ColumnmeritageGroupIndex | read-only | mandatory | Index into this table, by group number. |
| 1.3.6.1.4.1.81.32.3.1.1.2 | ColumnmeritageGroupTempExceed | read-only | mandatory | Fault condition indicating that temperature exceeded the threshold on the module. |
| 1.3.6.1.4.1.81.32.3.1.1.3 | ColumnmeritageGroupLEDsMap | read-only | mandatory | The status of all the Group LEDs in the form of a BIT Map. The coding of each LED is defined in MeritageLedColour. The structure of this item: Number of bits p… |
| 1.3.6.1.4.1.81.32.4 | NodemeritageClock | |||
| 1.3.6.1.4.1.81.32.4.1 | ScalarmeritageClockAdminStatus | read-write | mandatory | enable or disable the clock sync daughter board. When disabled, the M-SPS will use its own internal clock. |
| 1.3.6.1.4.1.81.32.4.2 | ScalarmeritageClockReset | read-write | mandatory | Setting the value of this attribute to ON causes a reset only to the Clock Sync daughter board and not to the M-SPS. |
| 1.3.6.1.4.1.81.32.4.3 | ScalarmeritageClockWTR | read-write | mandatory | The value in seconds of Wait Time to Restore. The time the M-SPS software will wait before restoring a healthy higher priority timing source as the sync source… |
| 1.3.6.1.4.1.81.32.4.4 | ScalarmeritageClockStatus | read-only | mandatory | The status of the Clock Sync daughter board: Locked - locked to the input timing source for more then 8 seconds. Holdover - Trying to simulate a clock it was p… |
| 1.3.6.1.4.1.81.32.4.5 | ScalarmeritageClockCurrentSource | read-only | mandatory | The current clock source being used. This is the outcome of the status of the sources and the priority between the sources. possible values are: ATM A, ATM B, … |
| 1.3.6.1.4.1.81.32.5 | NodemeritageClockSource | |||
| 1.3.6.1.4.1.81.32.5.1 | TablemeritageClockSourceTable | not-accessible | mandatory | A table containing information about each clock source in the hub. |
| 1.3.6.1.4.1.81.32.5.1.1 | RowmeritageClockSourceEntry | not-accessible | mandatory | An entry containing information about a particular clock source in the hub. |
| 1.3.6.1.4.1.81.32.5.1.1.1 | ColumnmeritageClockSourceIndex | read-only | mandatory | Index into this table, by clock source number 1-4. 1 - ATM A 2 - ATM B 3 - SYNC A 4 - SYNC B |
| 1.3.6.1.4.1.81.32.5.1.1.2 | ColumnmeritageClockSourceStatus | read-only | mandatory | The status of the source port ok - link ok los - loss of signal. failed - the source may have a link, but the M-SPS has failed 4 times to lock to it. The sourc… |
| 1.3.6.1.4.1.81.32.5.1.1.3 | ColumnmeritageClockSourcePriority | read-write | mandatory | The priority of the source port 0 - disabled 1 - lowest 4 - highest |
| 1.3.6.1.4.1.81.32.5.1.1.4 | ColumnmeritageClockSourceConfigPort | read-write | mandatory | The port assigned to drive the Clock Source. In the format X.Y - where X & Y are integers: 1st byte (X) - Slot number 2nd byte - (.) 3rd byte (Y) - Port number… |
| 1.3.6.1.4.1.81.32.5.1.1.5 | ColumnmeritageClockSourceFraming | read-write | mandatory | The framing mode for the SYNC A SYNC B ports. Sources ATM A and ATM will reply with notSupported (255). For M-SPS/ER and EB, the values 1 and 2 are relevant. F… |