MICROSEMI-PDSINE-MIB

64 objects
No module-level DESCRIPTION found.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.7428IdentitypolPowerOverLan
1.3.6.1.4.1.7428.1Nodeproducts
1.3.6.1.4.1.7428.1.1Nodedescription
1.3.6.1.4.1.7428.1.1.1NodesysObjectID
1.3.6.1.4.1.7428.1.1.1.1NodemidspanUnknown
1.3.6.1.4.1.7428.1.1.1.2Nodemidspan6portAC
1.3.6.1.4.1.7428.1.1.1.3Nodemidspan6portACDC
1.3.6.1.4.1.7428.1.1.1.4Nodemidspan12portAC
1.3.6.1.4.1.7428.1.1.1.5Nodemidspan12portACDC
1.3.6.1.4.1.7428.1.1.1.6Nodemidspan24portAC
1.3.6.1.4.1.7428.1.1.1.7Nodemidspan24portACDC
1.3.6.1.4.1.7428.1.1.1.8Nodemidspan48portAC
1.3.6.1.4.1.7428.1.1.1.9Nodemidspan48portACDC
1.3.6.1.4.1.7428.1.1.1.10Nodemidspan6portHPAC
1.3.6.1.4.1.7428.1.1.1.11Nodemidspan6portHPACDC
1.3.6.1.4.1.7428.1.1.1.12Nodemidspan12portHPAC
1.3.6.1.4.1.7428.1.1.1.13Nodemidspan12portHPACDC
1.3.6.1.4.1.7428.1.1.1.14NodemidspanGigabit6portAC
1.3.6.1.4.1.7428.1.1.1.15NodemidspanGigabit12portAC
1.3.6.1.4.1.7428.1.1.1.16NodemidspanGigabit24portAC
1.3.6.1.4.1.7428.1.1.1.17NodemidspanHiPoEGigabit6portAC
1.3.6.1.4.1.7428.1.1.1.18NodemidspanHiPoEGigabit12portAC
1.3.6.1.4.1.7428.1.1.1.19NodemidspanHiPoEGigabit24portAC
1.3.6.1.4.1.7428.1.1.1.20NodemidspanHiPoEATGigabit6portAC
1.3.6.1.4.1.7428.1.1.1.21NodemidspanHiPoEATGigabit12portACDC
1.3.6.1.4.1.7428.1.1.1.22NodemidspanHiPoEATGigabit24portACDC
1.3.6.1.4.1.7428.1.1.1.23Nodemidspan4PairATGigabit6portACDC
1.3.6.1.4.1.7428.1.1.1.24Nodemidspan4PairATGigabit12portACDC
1.3.6.1.4.1.7428.1.1.1.25NodemidspanHiPoEATGigabit6portDC
1.3.6.1.4.1.7428.1.1.1.26NodemidspanHiPoEATGigabit12portDC
1.3.6.1.4.1.7428.1.1.1.27NodemidspanHiPoEATGigabit24portDC
1.3.6.1.4.1.7428.1.1.1.28Nodemidspan4PairATGigabit24portACDC
1.3.6.1.4.1.7428.1.1.1.29NodemidspanEEPoEGigabit24portACDC
1.3.6.1.4.1.7428.1.1.1.30NodemidspanPoHGigabit6portACDC
1.3.6.1.4.1.7428.1.1.1.31NodemidspanPoHGigabit12portACDC
1.3.6.1.4.1.7428.1.1.1.32NodemidspanPoHGigabit24portACDC
1.3.6.1.4.1.7428.1.2NodepseDevice
1.3.6.1.4.1.7428.1.2.1NodeportObjects
1.3.6.1.4.1.7428.1.2.1.1TableportTablenot-accessiblecurrentA table of objects that display and control the power characteristics of power Ethernet ports on a Power Source Entity (PSE) device. This group will be impleme…
1.3.6.1.4.1.7428.1.2.1.1.1RowportEntrynot-accessiblecurrentA set of objects that display and control the power characteristics of a power Ethernet PSE port.
1.3.6.1.4.1.7428.1.2.1.1.1.1ColumnportGroupIndexnot-accessiblecurrentThis variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and …
1.3.6.1.4.1.7428.1.2.1.1.1.2ColumnportIndexnot-accessiblecurrentThis variable uniquely identifies the power Ethernet PSE port within group portGroupIndex to which the power Ethernet PSE entry is connected.
1.3.6.1.4.1.7428.1.2.1.1.1.3ColumnportConsumptionPowerread-onlycurrentA read-only value indicates the measured usage power expressed in Watts for a specific port
1.3.6.1.4.1.7428.1.2.1.1.1.4ColumnportMaxPowerread-writecurrentRead/Write maximum power consumption that PD device may consume in Watts NOTE: 1. For Midspan 60xx,60xxG,6500 series, Max PD power consumption = 17Watt 2. For …
1.3.6.1.4.1.7428.1.2.1.1.1.5ColumnportTyperead-writecurrentEnable/Disable Four-pair/EEPoE PoE Read : Applicable to all Midspan series Write: Applicable only to 95xxG/55xxG Midspan series twopair (1) Two-pair PoE port c…
1.3.6.1.4.1.7428.1.2.2NodemainObjects
1.3.6.1.4.1.7428.1.2.2.1TablemainPseTablenot-accessiblecurrentA table of objects that display and control attributes of the main PSE device.
1.3.6.1.4.1.7428.1.2.2.1.1RowmainPseEntrynot-accessiblecurrentA set of objects that display and control the Main PSE device.
1.3.6.1.4.1.7428.1.2.2.1.1.1ColumnmainGroupIndexnot-accessiblecurrentThis variable uniquely identifies the group to which power Ethernet PSE is connected. Group means (box in the stack, module in a rack) and the value 1 MUST be …
1.3.6.1.4.1.7428.1.2.2.1.1.2ColumnmainVoltageread-onlycurrentPower Supply Voltage in Volt.
1.3.6.1.4.1.7428.1.2.2.1.1.3ColumnmainDetectionMethodread-writecurrentRead/Write PD device detection method (802.3af / 802.3af+Legacy).
1.3.6.1.4.1.7428.1.2.2.1.1.4ColumnmainPowerUsageBudgetread-writecurrentAllow external SNMP manager to limit maximum power that all PD's may consume Whenever total power consumption exceeds maximum power, Midspan may turn off autom…
1.3.6.1.4.1.7428.1.2.2.1.1.5ColumnmainPSEMaxPowerread-onlycurrentMaximum power that Midspan can provide (Watt), after including power budget percentage limitation. Example: Midspan maximum power without power limit = 860Watt…
1.3.6.1.4.1.7428.1.2.2.1.1.6ColumnhighPowerLegacyPDSupportread-writecurrentApplicable only for Midspan 90xxG series enable (1) - Power Cisco 125x access point (pre 802.3at legacy high power PD device). disable(2) - Power only 802.3at …
1.3.6.1.4.1.7428.1.2.2.1.1.7ColumnhighPowerExtendedPortPowerread-writecurrentApplicable only for Midspan 90xxG/55xxG series enable (1) - Extend maximum power to PD device beyond 802.3at specification. disable(2) - Maximum power to PD de…
1.3.6.1.4.1.7428.1.2.2.1.1.8ColumnpowerBackupStatusread-onlycurrentApplicable only for Midspan 90xxG/95xxG/55xxG series standalone - Midspan isn't connected to any power backup device powerbackupbyrps - Redundant power supply …
1.3.6.1.4.1.7428.1.2.2.1.1.9ColumninternalPowerSourceStatusread-onlycurrentApplicable only for Midspan 90xxG/95xxG/55xxG series ok(1) - Internal Power Source is OK fail(2) - Internal Power Source failure
1.3.6.1.4.1.7428.1.2.2.1.1.10ColumnexternalPowerSourceStatusread-onlycurrentApplicable only for Midspan 90xxG/95xxG/55xxG series ok(1) - External Power Source is OK fail(2) - External Power Source failure notsupported(3) - SNMP GET res…
1.3.6.1.4.1.7428.1.2.2.1.1.11Columntemperatureread-onlycurrentUnit temperature - Applicable only for Midspan 95xxG series
1.3.6.1.4.1.7428.1.2.2.1.1.12Columntemperatureformatread-writecurrentUnit temperature format - Applicable only for Midspan 95xxG series Celcius(1) - Report unit temperature in Celcius Fahrenheit(2) - Report unit temperature in F…
1.3.6.1.4.1.7428.1.3NodepoeNotifications
1.3.6.1.4.1.7428.1.3.1NotificationpowerBackupStatusNotificationcurrentApplicable only for Midspan 90xxG/95xxG/55xxG series This Notification reports power backup status change, and whenever incompatible power backup source is con…
1.3.6.1.4.1.7428.1.3.2NotificationinternalPowerSourceStatusNotificationcurrentApplicable only for Midspan 90xxG/95xxG/55xxG series This Notification reports internal Power Source failure
1.3.6.1.4.1.7428.1.3.3NotificationexternalPowerSourceStatusNotificationcurrentApplicable only for Midspan 90xxG/95xxG/55xxG series This Notification reports external Power Source failure