MYLEXRAID-MIB
419 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | Counter enterprises |
| RFC1213-MIB | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1608 | Nodemylex | |||
| 1.3.6.1.4.1.1608.1 | NodedmtfStd | |||
| 1.3.6.1.4.1.1608.1.1 | NodedmtfComponents | |||
| 1.3.6.1.4.1.1608.1.1.1 | NodedmtfGroups | |||
| 1.3.6.1.4.1.1608.1.1.1.2 | TabletControllerInformation | not-accessible | mandatory | This group provides Controller Information. |
| 1.3.6.1.4.1.1608.1.1.1.2.1 | RoweControllerInformation | not-accessible | mandatory | |
| 1.3.6.1.4.1.1608.1.1.1.2.1.1 | Columna2ControllerNumber | read-only | mandatory | Controller Number assigned to this controller by the device driver. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.2 | Columna2OperationalState | read-only | mandatory | Operational state of this controller as seen by the device driver. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.3 | Columna2FirmwareRevision | read-only | mandatory | Controller Firmware Revision. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.4 | Columna2ConfiguredChannels | read-only | mandatory | Number of Channels that are part of controller configuration. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.5 | Columna2ActualChannels | read-only | mandatory | Number of Channels that are physically present on-board the controller. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.6 | Columna2MaximumLogicalDrives | read-only | mandatory | Maximum number of logical drives that can be configured on this controller. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.7 | Columna2MaximumTargetsPerChannel | read-only | mandatory | Maximum Number of Physical Target IDs supported per Channel |
| 1.3.6.1.4.1.1608.1.1.1.2.1.8 | Columna2MaximumTaggedRequests | read-only | mandatory | Maximum Number of Tagged requests that may be sent to a Hard disk device by Controller Firmware. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.9 | Columna2MaximumDataTransferSizePerIoRequestInK | read-only | mandatory | Maximum amount of data that can be transferred per a single IO request - in KB. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.10 | Columna2MaximumConcurrentCommands | read-only | mandatory | Maximum number of requests that can be sent to the controller simultaneouly. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.11 | Columna2RebuildRate | read-only | mandatory | Value of Rebuild Rate. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.12 | Columna2LogicalSectorSizeInBytes | read-only | mandatory | Logical Sector Size in Bytes (Default: 512 bytes). |
| 1.3.6.1.4.1.1608.1.1.1.2.1.13 | Columna2PhysicalSectorSizeInBytes | read-only | mandatory | Physical Sector Size in Bytes (Default: 512 bytes). |
| 1.3.6.1.4.1.1608.1.1.1.2.1.14 | Columna2CacheLineSizeInBytes | read-only | mandatory | Cache Line Size in Bytes. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.15 | Columna2CacheSizeInMb | read-only | mandatory | Size of Controller Cache Module - in MB. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.16 | Columna2CacheMemoryType | read-only | mandatory | Controller Cache Memory Type. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.17 | Columna2EpromSizeInKb | read-only | mandatory | Size of Controller EPROM Module - in KB. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.18 | Columna2BusType | read-only | mandatory | Controller - System Bus Interface Type. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.19 | Columna2ControllerClass | read-only | mandatory | Controller Class Type. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.20 | Columna2ControllerModel | read-only | mandatory | Controller Model Type. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.21 | Columna2SystemBusNumber | read-only | mandatory | System Bus Number, for the bus the controller is interfacing with. This value is supplied by the Operating system and may not be defined for all operating syst… |
| 1.3.6.1.4.1.1608.1.1.1.2.1.22 | Columna2SlotNumber | read-only | mandatory | Slot Number where the controller is physically present. Defined for EISA and MCA controller only. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.23 | Columna2InterruptVectorNumber | read-only | mandatory | Interrupt Vector Number being used by the controller. This value is a mapped IRQ supplied by Operating System and may not be same as the actual Interrupt Vecto… |
| 1.3.6.1.4.1.1608.1.1.1.2.1.24 | Columna2InterruptMode | read-only | mandatory | Interrupt Mode - Edge/Level. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.25 | Columna2NumberOfPhysicalDevices | read-only | mandatory | Number Of Physical Devices detected on this controller. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.26 | Columna2NumberOfPhysicalDevicesOffline | read-only | mandatory | Number of Physical Devices, whose operational state is Offline. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.27 | Columna2NumberOfLogicalDevices | read-only | mandatory | Number of Logical Devices currently configured. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.28 | Columna2NumberOfLogicalDevicesCritical | read-only | mandatory | Number of Logical Devices, whose operational state is Critical. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.29 | Columna2NumberOfLogicalDevicesOffline | read-only | mandatory | Number of Logical Devices, whose operational state is Offline. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.30 | Columna2FaultManagementType | read-only | mandatory | Controller Fault Management Type. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.31 | Columna2ArrayInformation | read-only | mandatory | Information about Array(s) definition. The information is provided in Channel-Target combination form. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.32 | Columna2LogicalDriveReadRequests | read-only | mandatory | Number of Read Requests to Logical Drives. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.33 | Columna2DataReadFromLogicalDrivesInMb | read-only | mandatory | Amount of Data Read from all Logical Drives - in MB. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.34 | Columna2LogicalDriveWriteRequests | read-only | mandatory | Number of Write Requests to Logical Drives. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.35 | Columna2DataWrittenToLogicalDrivesInMb | read-only | mandatory | Amount of data written to all Logical Drives - in MB. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.36 | Columna2LogicalDrivesReadCacheHitPercentage | read-only | mandatory | Logical Drives Read Data Cache Hit Rate. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.37 | Columna2PhysicalDriveReadRequests | read-only | mandatory | Number of Read Requests to all physical drives. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.38 | Columna2DataReadFromPhysicalDrivesInMb | read-only | mandatory | Amount of Data Read from all physical drives - in MB. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.39 | Columna2PhysicalDriveWriteRequests | read-only | mandatory | Number of Write Requests to all physical drives on this controll r. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.40 | Columna2DataWrittenToPhysicalDrivesInMb | read-only | mandatory | Amount of data written all physical drives on this controller- in MB. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.41 | Columna2StorageworksCabinetStatusOnChannel0 | read-only | mandatory | StorageWorks Cabinet Status on Channel 0 |
| 1.3.6.1.4.1.1608.1.1.1.2.1.42 | Columna2StorageworksCabinetStatusOnChannel1 | read-only | mandatory | StorageWorks Cabinet Status on Channel 1 |
| 1.3.6.1.4.1.1608.1.1.1.2.1.43 | Columna2StorageworksCabinetStatusOnChannel2 | read-only | mandatory | StorageWorks Cabinet Status on Channel 2 |
| 1.3.6.1.4.1.1608.1.1.1.2.1.44 | Columna2BatteryBackupUnitStatus | read-only | mandatory | Battery Backup Unit Status. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.45 | Columna2PartnerControllerNumber | read-only | mandatory | Controller Number of the Partner Controller. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.46 | Columna2WwName | read-only | mandatory | Controller World Wide Name. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.47 | Columna2HostControllerNumber | read-only | mandatory | Host Controller Number. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.48 | Columna2HostChannelNumber | read-only | mandatory | Host Channel Number. |
| 1.3.6.1.4.1.1608.1.1.1.2.1.49 | Columna2HostTargetId | read-only | mandatory | Host Target ID. |
| 1.3.6.1.4.1.1608.1.1.1.3 | TabletLogicalDriveInformation | not-accessible | mandatory | Provides information about Logical Drive Configuration. |
| 1.3.6.1.4.1.1608.1.1.1.3.1 | RoweLogicalDriveInformation | not-accessible | mandatory | |
| 1.3.6.1.4.1.1608.1.1.1.3.1.1 | Columna3ControllerNumber | read-only | mandatory | Controller Number - used as a key. |
| 1.3.6.1.4.1.1608.1.1.1.3.1.2 | Columna3LogicalDriveNumber | read-only | mandatory | Logical Drive Number - used as a Key. |
| 1.3.6.1.4.1.1608.1.1.1.3.1.3 | Columna3OperationalState | read-only | mandatory | Logical Drive Operational State. |
| 1.3.6.1.4.1.1608.1.1.1.3.1.4 | Columna3RaidLevel | read-only | mandatory | RAID Level associated with Logical Drive. |
| 1.3.6.1.4.1.1608.1.1.1.3.1.5 | Columna3WritePolicy | read-only | mandatory | Write Cache Policy associated with Logical Drive. |
| 1.3.6.1.4.1.1608.1.1.1.3.1.6 | Columna3SizeInMb | read-only | mandatory | Logical Drive Size - in MB. |
| 1.3.6.1.4.1.1608.1.1.1.3.1.7 | Columna3PhysicalSizeInMb | read-only | mandatory | Total physical capacity used by this Logical Drive - in MB. |
| 1.3.6.1.4.1.1608.1.1.1.3.1.8 | Columna3StripeSizeInBytes | read-only | mandatory | Stripe size associated with Logical Drive. Valid for RAID Levels 0, 5 and 6 only. Value is specifed in bytes. |
| 1.3.6.1.4.1.1608.1.1.1.3.1.9 | Columna3PhysicalDriveMap | read-only | mandatory | List of all physical drives that make up this Logical Drive. The information is provided in Channel-Target combination form. |
| 1.3.6.1.4.1.1608.1.1.1.3.1.10 | Columna3ArrayList | read-only | mandatory | List of Arrays, this logical drive spans across. |
| 1.3.6.1.4.1.1608.1.1.1.3.1.11 | Columna3RaidLevelString | read-only | mandatory | Raid Level String. |
| 1.3.6.1.4.1.1608.1.1.1.4 | TabletPhysicalDeviceInformation | not-accessible | mandatory | SCSI Physical Device Information. |
| 1.3.6.1.4.1.1608.1.1.1.4.1 | RowePhysicalDeviceInformation | not-accessible | mandatory | |
| 1.3.6.1.4.1.1608.1.1.1.4.1.1 | Columna4ControllerNumber | read-only | mandatory | Controller Number - used as a key |
| 1.3.6.1.4.1.1608.1.1.1.4.1.2 | Columna4ChannelNumber | read-only | mandatory | Channel Number - used as a key |
| 1.3.6.1.4.1.1608.1.1.1.4.1.3 | Columna4TargetId | read-only | mandatory | Physical Device Target Id - used as a key |
| 1.3.6.1.4.1.1608.1.1.1.4.1.4 | Columna4Lun | read-only | mandatory | LUN of the Physical Device. |
| 1.3.6.1.4.1.1608.1.1.1.4.1.5 | Columna4OperationalState | read-only | mandatory | Physical Device State. |
| 1.3.6.1.4.1.1608.1.1.1.4.1.6 | Columna4VendorId | read-only | mandatory | Physical Device Vendor Id. |
| 1.3.6.1.4.1.1608.1.1.1.4.1.7 | Columna4ProductId | read-only | mandatory | Physical Device Product Id. |
| 1.3.6.1.4.1.1608.1.1.1.4.1.8 | Columna4ProductRevisionLevel | read-only | mandatory | Physical Device Product Revision Level. |
| 1.3.6.1.4.1.1608.1.1.1.4.1.9 | Columna4SizeInMb | read-only | mandatory | Physcical Capacity in MB, valid for physical drive only. |
| 1.3.6.1.4.1.1608.1.1.1.4.1.10 | Columna4DeviceType | read-only | mandatory | Device Type. |
| 1.3.6.1.4.1.1608.1.1.1.4.1.11 | Columna4SoftErrors | read-only | mandatory | Number of Soft Errors, valid for physical drive only. |
| 1.3.6.1.4.1.1608.1.1.1.4.1.12 | Columna4HardErrors | read-only | mandatory | Number of Hard Errors, valid for physical drive only. |
| 1.3.6.1.4.1.1608.1.1.1.4.1.13 | Columna4ParityErrors | read-only | mandatory | Number of Parity Errors, valid for physical drive only. |
| 1.3.6.1.4.1.1608.1.1.1.4.1.14 | Columna4MiscErrors | read-only | mandatory | Number of Misc Errors, valid for physical drive only. |
| 1.3.6.1.4.1.1608.1.1.1.4.1.15 | Columna4ArrayList | read-only | mandatory | List Of Arrays of which this physical drive is part, if applicab e. |
| 1.3.6.1.4.1.1608.1.1.1.4.1.16 | Columna4LogicalDriveList | read-only | mandatory | List of Logical Drives that depend on this physical drive, if applicable. |
| 1.3.6.1.4.1.1608.1.1.1.4.1.17 | Columna4BusSpeed | read-only | mandatory | Bus Transfer Speed |
| 1.3.6.1.4.1.1608.1.1.1.4.1.18 | Columna4BusWidth | read-only | mandatory | Bus Width |
| 1.3.6.1.4.1.1608.1.1.1.4.1.19 | Columna4CommandQueuing | read-only | mandatory | Command Tagged Queuing Enabled |
| 1.3.6.1.4.1.1608.1.1.1.4.1.20 | Columna4PfaErrors | read-only | mandatory | SMART PFA Error Count, valid for physical drive only. |
| 1.3.6.1.4.1.1608.1.1.1.5 | NodetMylexDacManagementSoftware | |||
| 1.3.6.1.4.1.1608.1.1.1.5.1 | NodeeMylexDacManagementSoftware | |||
| 1.3.6.1.4.1.1608.1.1.1.5.1.1 | Scalara5ManagementSoftwareRevision | read-only | mandatory | Mylex DAC Management Software Revision Information. |
| 1.3.6.1.4.1.1608.1.1.1.5.1.2 | Scalara5ManagementSoftwareBuildDate | read-only | mandatory | Mylex DAC Management Software Build Date Information - month/dat /year format. |
| 1.3.6.1.4.1.1608.1.1.1.5.1.3 | Scalara5MylexDacDeviceDriverRevision | read-only | mandatory | Mylex DAC Device driver Revision Information. |
| 1.3.6.1.4.1.1608.1.1.1.5.1.4 | Scalara5MylexDacDeviceDriverBuildDate | read-only | mandatory | Mylex DAC Device Driver Build Date Information - month/date/year format. |
| 1.3.6.1.4.1.1608.1.1.1.5.1.5 | Scalara5GamDriverRevision | read-only | mandatory | Mylex GAM Driver Revision Information. |
| 1.3.6.1.4.1.1608.1.1.1.5.1.6 | Scalara5GamDriverBuildDate | read-only | mandatory | Mylex GAM Driver Build Date Information - date/month/year format. |
| 1.3.6.1.4.1.1608.1.1.1.6 | TabletLogicalDriveStatistics | not-accessible | mandatory | Logical Drive Performance Statistics |
| 1.3.6.1.4.1.1608.1.1.1.6.1 | RoweLogicalDriveStatistics | not-accessible | mandatory | |
| 1.3.6.1.4.1.1608.1.1.1.6.1.1 | Columna6ControllerNumber | read-only | mandatory | Controller Number - used as a key. |
| 1.3.6.1.4.1.1608.1.1.1.6.1.2 | Columna6LogicalDriveNumber | read-only | mandatory | Logical Drive Number - used as a key. |
| 1.3.6.1.4.1.1608.1.1.1.6.1.3 | Columna6ReadRequests | read-only | mandatory | Number of Read Requests. |
| 1.3.6.1.4.1.1608.1.1.1.6.1.4 | Columna6DataReadInMb | read-only | mandatory | Amount of Data Read from this logical drive - in MB. |
| 1.3.6.1.4.1.1608.1.1.1.6.1.5 | Columna6WriteRequests | read-only | mandatory | Number of Write Requests. |
| 1.3.6.1.4.1.1608.1.1.1.6.1.6 | Columna6DataWrittenInMb | read-only | mandatory | Amount of data written - in MB. |
| 1.3.6.1.4.1.1608.1.1.1.6.1.7 | Columna6ReadCacheHitPercentage | read-only | mandatory | Read Cache Hit Rate. |
| 1.3.6.1.4.1.1608.1.1.1.7 | TabletPhysicalDriveStatistics | not-accessible | mandatory | Physical Drive Performance Statistics |
| 1.3.6.1.4.1.1608.1.1.1.7.1 | RowePhysicalDriveStatistics | not-accessible | mandatory | |
| 1.3.6.1.4.1.1608.1.1.1.7.1.1 | Columna7ControllerNumber | read-only | mandatory | Controller Number - used as a key. |
| 1.3.6.1.4.1.1608.1.1.1.7.1.2 | Columna7ChannelNumber | read-only | mandatory | Channel Number - used as a key. |
| 1.3.6.1.4.1.1608.1.1.1.7.1.3 | Columna7TargetId | read-only | mandatory | Physical Device Target Id - used as a key. |
| 1.3.6.1.4.1.1608.1.1.1.7.1.4 | Columna7Lun | read-only | mandatory | LUN of the Physical Device. |
| 1.3.6.1.4.1.1608.1.1.1.7.1.5 | Columna7ReadRequests | read-only | mandatory | Number of Read Requests. |
| 1.3.6.1.4.1.1608.1.1.1.7.1.6 | Columna7DataReadInMb | read-only | mandatory | Amount of Data Read - in MB. |
| 1.3.6.1.4.1.1608.1.1.1.7.1.7 | Columna7WriteRequests | read-only | mandatory | Number of Write Requests. |
| 1.3.6.1.4.1.1608.1.1.1.7.1.8 | Columna7DataWrittenInMb | read-only | mandatory | Amount of data written - in MB. |
| 1.3.6.1.4.1.1608.1.1.1.8 | TabletFaultManagementCabinetInformation | not-accessible | mandatory | Fault Management Cabinet Information. |
| 1.3.6.1.4.1.1608.1.1.1.8.1 | RoweFaultManagementCabinetInformation | not-accessible | mandatory | |
| 1.3.6.1.4.1.1608.1.1.1.8.1.1 | Columna8ControllerNumber | read-only | mandatory | Controller Number - used as a key. |
| 1.3.6.1.4.1.1608.1.1.1.8.1.2 | Columna8ChannelNumber | read-only | mandatory | Channel Number of the Channel to which the Cabinet is connected - used as a key. |
| 1.3.6.1.4.1.1608.1.1.1.8.1.3 | Columna8CabinetNumber | read-only | mandatory | Cabinet Number - used as a key. |
| 1.3.6.1.4.1.1608.1.1.1.8.1.4 | Columna8TargetId | read-only | mandatory | Target Id of the Cabinet. |
| 1.3.6.1.4.1.1608.1.1.1.8.1.5 | Columna8Lun | read-only | mandatory | LUN of the Cabinet. |
| 1.3.6.1.4.1.1608.1.1.1.8.1.6 | Columna8CabinetType | read-only | mandatory | Fault Management Cabinet Type, such as Conner CR6, Conner Smart and SAFTE etc. |
| 1.3.6.1.4.1.1608.1.1.1.8.1.7 | Columna8NumberOfFans | read-only | mandatory | Number of Fans in the cabinet. |
| 1.3.6.1.4.1.1608.1.1.1.8.1.8 | Columna8NumberOfPowerSupplyUnits | read-only | mandatory | Number of Power Supply Units in the cabinet. |
| 1.3.6.1.4.1.1608.1.1.1.8.1.9 | Columna8NumberOfHeatSensors | read-only | mandatory | Number of Heat Sensors in the cabinet. |
| 1.3.6.1.4.1.1608.1.1.1.8.1.10 | Columna8NumberOfDriveSlots | read-only | mandatory | Number of Drive Slots in the cabinet. |
| 1.3.6.1.4.1.1608.1.1.1.8.1.11 | Columna8NumberOfDoorLocks | read-only | mandatory | Number of Door Locks in the cabinet. |
| 1.3.6.1.4.1.1608.1.1.1.8.1.12 | Columna8NumberOfSpeakers | read-only | mandatory | Number of Speakers in the cabinet. |
| 1.3.6.1.4.1.1608.1.1.1.8.1.13 | Columna8NumberOfFansCritical | read-only | mandatory | Number of Fans in Critical State in the cabinet. |
| 1.3.6.1.4.1.1608.1.1.1.8.1.14 | Columna8NumberOfPowerSupplyUnitsCritical | read-only | mandatory | Number of Power Supply Units in Critical state in the cabinet. |
| 1.3.6.1.4.1.1608.1.1.1.8.1.15 | Columna8NumberOfHeatSensorsCritical | read-only | mandatory | Number of Heat Sensors in Critical state in the cabinet. |
| 1.3.6.1.4.1.1608.1.1.1.8.1.16 | Columna8NumberOfFansFailed | read-only | mandatory | Number of Fans in Failed State in the cabinet. |
| 1.3.6.1.4.1.1608.1.1.1.8.1.17 | Columna8NumberOfPowerSupplyUnitsFailed | read-only | mandatory | Number of Power Supply Units in Failed state in the cabinet. |
| 1.3.6.1.4.1.1608.1.1.1.8.1.18 | Columna8NumberOfHeatSensorsFailed | read-only | mandatory | Number of Heat Sensors in Failed state in the cabinet. |
| 1.3.6.1.4.1.1608.1.1.1.9 | TabletMylexRaidEventInformation | not-accessible | mandatory | Event Information for Mylex RAID events. |
| 1.3.6.1.4.1.1608.1.1.1.9.1 | RoweMylexRaidEventInformation | not-accessible | mandatory | |
| 1.3.6.1.4.1.1608.1.1.1.9.1.1 | Columna9EventTableIndex | read-only | mandatory | Index to the event table, Used as a key. A total number of 256 events can be stored in the event table. However, the Event Table Index can be greater than 256 |
| 1.3.6.1.4.1.1608.1.1.1.9.1.1 | NodephysdevOnline | A physical disk has been placed online. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.2 | Columna9EventCode | read-only | mandatory | Mylex RAID event code. |
| 1.3.6.1.4.1.1608.1.1.1.9.1.2 | NodephysdevHotspare | A physical disk has been added as hot spare. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.3 | Columna9EventTimeStamp | read-only | mandatory | Time Stamp associated with this event. It's the number of seconds since midnight(00:00:00) January 1, 1970 GMT. |
| 1.3.6.1.4.1.1608.1.1.1.9.1.3 | NodephysdevHardError | Physical disk error found. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.4 | Columna9ControllerNumber | read-only | mandatory | Controller Number of the controller, which causes the event, if applicable |
| 1.3.6.1.4.1.1608.1.1.1.9.1.4 | NodephysdevPfa | Physical disk PFA condition found; this disk may fail soon. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.5 | Columna9ChannelNumber | read-only | mandatory | Channel Number of the device, which causes the event, if applicable |
| 1.3.6.1.4.1.1608.1.1.1.9.1.5 | NodephysdevAutoRebuildStart | An automatic rebuild has started. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.6 | Columna9TargetId | read-only | mandatory | Target Id of the physical device, which causes the event, if applicable |
| 1.3.6.1.4.1.1608.1.1.1.9.1.6 | NodephysdevManualRebuildStart | A rebuild has started. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.7 | Columna9Lun | read-only | mandatory | LUN of the device, which causes the event, if applicable |
| 1.3.6.1.4.1.1608.1.1.1.9.1.7 | NodephysdevRebuildDone | Rebuild is over. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.8 | Columna9LogicalDriveNumber | read-only | mandatory | Drive Number of the Logical Drive, which causes the event, if applicable |
| 1.3.6.1.4.1.1608.1.1.1.9.1.8 | NodephysdevRebuildCanceled | Rebuild is cancelled. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.9 | Columna9FmtCabinetNumber | read-only | mandatory | Fault Management Cabinet Number of the cabinet, which causes the event, if applicable |
| 1.3.6.1.4.1.1608.1.1.1.9.1.9 | NodephysdevRebuildError | Rebuild stopped with error. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.10 | Columna9FanUnitNumber | read-only | mandatory | Unit Number of the fan which, causes the event, if applicable |
| 1.3.6.1.4.1.1608.1.1.1.9.1.10 | NodephysdevRebuildNewdevFailed | Rebuild stopped with error. New physical disk failed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.11 | Columna9PowerSupplyUnitNumber | read-only | mandatory | Unit Nubmer of the PSU which, causes the event, if applicable |
| 1.3.6.1.4.1.1608.1.1.1.9.1.11 | NodephysdevRebuildSysdevFailed | Rebuild stopped because logical drive failed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.12 | Columna9HeatSensorUnitNumber | read-only | mandatory | Unit Number of the Heat Sensor, which causes the event, if applicable |
| 1.3.6.1.4.1.1608.1.1.1.9.1.12 | NodephysdevDead | A physical disk has failed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.13 | Columna9EnclosureUnitNumber | read-only | mandatory | Unit Number of the Enclosure Unit, which causes the event, if applicable |
| 1.3.6.1.4.1.1608.1.1.1.9.1.13 | NodephysdevFound | A new physical disk has been found. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.14 | NodephysdevGone | A physical disk has been removed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.15 | NodephysdevUnconfigured | A previously configured physical disk is now available. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.16 | NodephysdevExpandcapacityStart | Expand Capacity Started. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.17 | NodephysdevExpandcapacityDone | Expand Capacity Completed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.18 | NodephysdevExpandcapacityError | Expand Capacity Stopped with error. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.19 | NodephysdevCommandTimeout | SCSI command timeout on physical device. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.20 | NodephysdevCommandAbort | SCSI command abort on physical disk. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.21 | NodephysdevCommandRetried | SCSI command retried on physical disk. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.22 | NodephysdevParityError | Parity error found. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.23 | NodephysdevSoftError | Soft error found. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.24 | NodephysdevMiscError | Misc error found. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.25 | NodephysdevReset | SCSI device reset. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.26 | NodephysdevActivespare | Active spare found. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.27 | NodephysdevWarmspare | Warm spare found. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.28 | NodephysdevReqsense | Request Sense Data available. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.29 | NodephysdevInitStarted | Initialization started. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.30 | NodephysdevInitDone | Initialization completed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.31 | NodephysdevInitFailed | Initialization failed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.32 | NodephysdevInitCanceled | Initialization canceled. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.33 | NodephysdevWriterecDead | A physical disk failed because write recovery failed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.34 | NodephysdevResetDead | A physical disk failed because SCSI bus reset failed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.35 | NodephysdevDblccDead | A physical disk failed because double check condition occured. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.36 | NodephysdevRemovedDead | A physical disk failed because device is missing. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.37 | NodephysdevGrosserrDead | A physical disk failed because of gross error on SCSI processor. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.38 | NodephysdevBadtagDead | A physical disk failed because of invalid tag. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.39 | NodephysdevScsitmoDead | A physical disk failed because a command timed out. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.40 | NodephysdevSysresetDead | A physical disk failed because of the system reset. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.41 | NodephysdevBsyparDead | A physical disk failed because of busy status or parity error. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.42 | NodephysdevBycmdDead | A physical disk set to failed state by host. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.43 | NodephysdevSeltmoDead | A physical disk failed because access to the device met with a selection time out. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.44 | NodephysdevSeqerrDead | A physical disk failed because of a sequence error in the SCSI bus phase handling. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.45 | NodephysdevUnknownstsDead | A physical disk failed because device returned an unknown status. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.46 | NodephysdevNotrdyDead | A physical disk failed because device is not ready. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.47 | NodephysdevMissingDead | A physical disk failed because device was not found on start up. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.48 | NodephysdevCodwrfailDead | A physical disk failed because write operation of the 'Configuration On Disk' failed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.49 | NodephysdevBdtwrfailDead | A physical disk failed because write operation of 'Bad Data Table' failed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.50 | NodephysdevOffline | Physical disk status changed to offline. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.51 | NodephysdevStandby | Physical disk status changed to hot spare. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.52 | NodephysdevRebuild | Physical disk status changed to rebuild. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.53 | NodephysdevIdMismatch | Physical device ID did not match. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.54 | NodephysdevFailedStart | Physical disk failed to start. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.55 | NodephysdevOffsetSet | Physical disk negotiated different offset than config. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.56 | NodephysdevSetBusWidth | Physical disk negotiated different bus width than config. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.57 | NodephysdevMissingOnstartup | Physical disk missing on startup. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.58 | NodephysdevRebuildStartFailed | Rebuild startup failed due to lower physical disk capacity. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.59 | NodephysdevMovingToOtherChn | Physical disk is switching from one channel to the other channel. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.60 | NodephysdevOfflineDeviceMadeOnline | Temporary-Dead physical disk is automatically made online. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.61 | NodephysdevStandbyRebuildStart | A standby rebuild has started. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.62 | NodephysdevHotSpareSmaller | Hot spare replaced with a smaller capacity physical disk. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.63 | NodeppilotLogicalDiskOnline | A storage access path has come online. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.64 | NodeppilotLogicalDiskOffline | A storage access path has been lost. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.65 | NodeppilotLogicalDiskPathFailover | A storage access path has shifted to the alternate path. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.66 | NodeppilotLogicalDiskPathFailback | A storage access path has shifted to the primary path. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.67 | NodephysdevNonRedundantAccess | Physical Disk found on only one disk channel. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.68 | NodephysdevTypeInvalid | Physical disk type is not approved by vendor. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.69 | NodephysdevSoftId | Physical disk has acquired an inappropriate loop ID. Enclosure disk-slot operations are disabled while this condition persists. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.70 | NodephysdevPortFailed | Physical disk port has failed or cannot operate at the configured channel speed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.71 | NodectldevMirrorRaceEntryFailed | Mirror Race recovery failed for logical drive. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.72 | NodectldevCtrlParamsChecksumFailed | |||
| 1.3.6.1.4.1.1608.1.1.1.9.1.73 | NodefirmwareUpgradeStarted | Online controller firmware upgrade has started. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.74 | NodefirmwareUpgradeComplete | Online firmware upgrade has completed successfully. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.75 | NodefirmwareUpgradeFailed | Online firmware upgrade has failed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.96 | NodefibredevLoopidSoftaddrOccurred | Device loop ID conflict (soft addressing) detected. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.128 | NodesysdevCheckStart | Consistency check is started. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.129 | NodesysdevCheckDone | Consistency check is finished. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.130 | NodesysdevCheckCanceled | Consistency check is cancelled. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.131 | NodesysdevCheckError | Consistency check on logical drive error. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.132 | NodesysdevCheckSysdevFailed | Consistency check on logical drive failed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.133 | NodesysdevCheckPhysdevFailed | Consistency check failed due to physical disk failure. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.134 | NodesysdevOffline | Logical drive has been made offline. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.135 | NodesysdevCritical | Logical drive is critical. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.136 | NodesysdevOnline | Logical drive has been placed online. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.137 | NodesysdevAutoRebuildStart | An automatic rebuild has started on logical drive. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.138 | NodesysdevManualRebuildStart | A manual rebuild has started on logical drive. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.139 | NodesysdevRebuildDone | Rebuild on logical drive is over. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.140 | NodesysdevRebuildCanceled | Rebuild on logical drive is cancelled. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.141 | NodesysdevRebuildError | Rebuild stopped with error. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.142 | NodesysdevRebuildNewdevFailed | Rebuild stopped with error. New physical disk failed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.143 | NodesysdevRebuildSysdevFailed | Rebuild stopped because logical drive failed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.144 | NodesysdevInitStarted | Logical drive initialization started. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.145 | NodesysdevInitDone | Logical drive initialization done. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.146 | NodesysdevInitCanceled | Logical drive initialization cancelled. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.147 | NodesysdevInitFailed | Logical drive initialization failed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.148 | NodesysdevFound | A logical drive has been found. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.149 | NodesysdevGone | A logical drive has been deleted. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.150 | NodesysdevExpandcapacityStart | Expand capacity started. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.151 | NodesysdevExpandcapacityDone | Expand capacity completed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.152 | NodesysdevExpandcapacityError | Expand capacity stopped with error. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.153 | NodesysdevBadblock | Bad Blocks found. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.154 | NodesysdevSizechanged | Logical drive size changed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.155 | NodesysdevTypechanged | Logical drive type changed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.156 | NodesysdevBaddatablock | Bad data blocks found. Possible data loss. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.157 | NodesysdevWrLunMap | Logical drive LUN mapping has been written to config. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.158 | NodesysdevDatareadFromBlockInBdt | Attempt to read data from block that is marked in Bad Data Table. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.159 | NodesysdevDataForBlockLost | Data for Disk Block has been lost due to Logical Drive problem. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.160 | NodesysdevOfflineDeviceMadeAvailableWithDataloss | Temporary-Offline RAID5/RAID3 array is available to the user again with the possibility of data loss in the array. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.161 | NodesysdevOfflineDeviceMadeAvailable | Temporary-Offline RAID0+1/RAID1/RAID0/JBOD array is available to the user again. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.162 | NodesysdevStandbyRebuildStart | A standby rebuild has started on a logical drive. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.176 | NodesysdevBgInitStarted | Logical drive background initialization started. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.177 | NodesysdevBgInitStopped | Logical drive background initialization stopped. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.178 | NodesysdevBgInitPaused | Logical drive background initialization paused. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.179 | NodesysdevBgInitRestarted | Logical drive background initialization restarted. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.180 | NodesysdevBgInitFailed | Logical drive background initialization failed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.181 | NodesysdevBgInitCompleted | Logical drive background initialization completed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.182 | NodesysdevDataLossLowBbuCharge | Low battery charge level. Logical drive may have lost data. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.256 | NodefmtfanFailed | Fan failure. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.257 | NodefmtfanOk | Fan has been restored. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.258 | NodeaemiFanFailed | Fan failure. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.259 | NodefmtfanNotpresent | Storage cabinet fan is not present. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.272 | NodefmtpowerFailed | Power supply failure. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.273 | NodefmtpowerOk | Power supply has been restored. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.274 | NodeaemiPwrSupplyFailed | Power supply failure. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.275 | NodefmtpowerNotpresent | Storage cabinet power supply is not present. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.288 | NodefmtheatBad | Over temperature. Temperature is above 70 degrees Celsius. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.289 | NodefmtheatCritical | Temperature is above 50 degrees Celsius. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.290 | NodefmtheatOk | Normal temperature has been restored. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.291 | NodeaemiOverTemperature | Over temperature. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.292 | NodefmtheatNotpresent | Storage cabinet temperature sensor is not present. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.304 | NodefmtstwkFailed | Storage Works enclosure reported failure state. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.305 | NodefmtstwkCritical | Storage Works enclosure reported critical state. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.306 | NodefmtstwkOk | Storage Works enclosure reported normal state. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.307 | NodefmtUpsDisabled | Uninterruptible power supply disabled. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.308 | NodefmtUpsAcFail | Uninterruptible power supply ac failed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.309 | NodefmtUpsBatLow | Uninterruptible power supply battery low. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.310 | NodefmtUpsFailed | Uninterruptible power supply failed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.311 | NodefmtUpsOk | Uninterruptible power supply normal. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.320 | NodeenclfanFailed | Fan failure. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.321 | NodeenclfanOk | Fan has been restored. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.322 | NodeenclfanNotpresent | Fan is not present. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.323 | NodeenclpowerFailed | Power supply failure. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.324 | NodeenclpowerOk | Power supply has been restored. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.325 | NodeenclpowerNotpresent | Power supply is not present. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.326 | NodeenclheatBad | Temperature is over safe limit. Failure imminent. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.327 | NodeenclheatCritical | Temperature is above working limit. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.328 | NodeenclheatOk | Normal temperature has been restored. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.329 | NodeenclheatNotpresent | Temperature sensor is not present. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.330 | NodeenclaccessCritical | Enclosure access critical. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.331 | NodeenclaccessOk | Enclosure access has been restored. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.332 | NodeenclaccessOffline | Enclosure access is offline. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.333 | NodeenclsesSoftaddrOccurred | Enclosure soft addressing detected. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.334 | NodeenclaccessReady | Enclosure services ready. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.335 | NodeenclheatUnknown | Access to temperature sensor has been lost. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.336 | NodeenclpowerUnknown | Access to power supply status information has been lost. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.337 | NodeenclfanUnknown | Access to fan status information has been lost. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.338 | NodeenclosureShutdown | Physical disks in enclosure being spundown. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.339 | NodeenclcoldWarn | Temperature is below working limit. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.340 | NodeenclcoldFail | Temperature is under safe limit. Failure imminent. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.384 | NodesystemStarted | Array management server software started successfully. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.385 | NodectldevWritebackError | Write back error. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.386 | NodectldevStateTableFull | Internal log structures getting full,PLEASE SHUTDOWN AND RESET THE SYSTEM IN THE NEAR FUTURE. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.388 | NodectldevDead | Controller is dead. System is disconnecting from this controller. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.389 | NodectldevReset | Controller has been reset. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.390 | NodectldevFound | Controller is found. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.391 | NodectldevGone | Controller is gone. System is disconnecting from this controller. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.392 | NodectldevBbuFound | Battery present. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.393 | NodectldevBbuPowerLow | Battery power low. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.394 | NodectldevBbuPowerOk | Battery power OK. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.395 | NodectldevPowerOff | Controller is gone. System is disconnecting from this controller. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.396 | NodectldevPowerOn | Controller powered on | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.397 | NodectldevOnline | Controller is online. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.398 | NodectldevOffline | Controller is gone. System is disconnecting from this controller. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.399 | NodectldevCritical | Controller's partner is gone, controller is in failover mode now. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.400 | NodectldevBbuRecondStart | Battery reconditioning is started. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.401 | NodectldevBbuRecondDone | Battery reconditioning is finished. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.402 | NodectldevBbuRecondAbort | Battery reconditioning is canceled. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.403 | NodectldevInstallationAborted | Installation aborted. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.404 | NodectldevFirmwareMismatch | Controller firmware mismatch. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.405 | NodectldevBbuNoresponse | The Battery Backup Unit is removed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.406 | NodectldevWarmBootError | WARM BOOT failed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.407 | NodectldevBbuCalibrateStart | Battery calibration cycle started. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.408 | NodectldevBbuCalibrateDone | Battery calibration cycle finished. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.409 | NodectldevBbuCalibrateAbort | Battery calibration cycle was cancelled. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.410 | NodectldevBbuNoBattery | Battery is not present. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.411 | NodectldevConservCacheMode | Controller entered conservative cache mode. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.412 | NodectldevNormalCacheMode | Controller entered normal cache mode. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.413 | NodectldevDevStartCmplt | Controller device start complete. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.414 | NodectldevSoftEccCorrected | Soft ECC error corrected. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.415 | NodectldevHardEccCorrected | Hard ECC error corrected. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.416 | NodectldevBbuRecondNeeded | Battery recondition suggested. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.417 | NodectldevRemovedPtnr | Controller's partner has been removed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.418 | NodectldevBbuOutOfService | BBU out of service. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.419 | NodectldevUpdatePtnrStatus | Updated partner's status. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.420 | NodectldevRelinquishPtnr | Relinquished partner. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.421 | NodectldevInsertedPtnr | Inserted partner. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.422 | NodectldevDualEnabled | Dual controllers enabled. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.423 | NodectldevKillPtnr | Disabled partner. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.424 | NodectldevNexus | Dual controllers entered nexus. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.425 | NodectldevBadBootromImage | Controller boot ROM image needs to be reloaded. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.426 | NodectldevBadMacAddress | Controller is using default non-unique world-wide name. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.427 | NodectldevMirrorRaceRecoveryFailed | Mirror Race recovery failed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.428 | NodectldevMirrorCriticalDrive | Mirror Race on critical logical drive. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.429 | NodectldevInCluster | Controller connected to cluster. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.430 | NodectldevNotInCluster | Controller disconnected from cluster. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.431 | NodesysdevDataLossImproperShutdown | Controller improperly shutdown! Data may have been lost. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.432 | NodectldevAutomaticFlashStarted | Dual-active automatic flash of replacement controller. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.433 | NodectldevNegotiationFailedJumpers | Dual-active negotiation failed jumpers. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.434 | NodectldevNegotiationSameId | Dual-active negotiation failed IDs. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.435 | NodectldevNegotiationBoardType | Dual-active negotiation failed board types. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.436 | NodectldevNegotiationDiskChannels | Dual-active negotiation failed disk channels. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.437 | NodectldevNegotiationHostChannels | Dual-active negotiation failed host ports. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.438 | NodectldevNegotiationMemorySize | Dual-active negotiation failed memory size. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.439 | NodectldevNegotiationCacheSize | Dual-active negotiation failed cache memory size. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.440 | NodectldevMirrorRaceTableError | Error in Mirror Race Table. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.441 | NodectldevStopRejected | A replacement controller attempted to stop the surviving | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.512 | NodesystemStartedNew | System started. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.513 | NodesystemSizeTableFull | Size table full. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.514 | NodesystemUserLoggedIn | User logged in. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.515 | NodesystemUserLoggedOut | User logged out. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.516 | NodesystemAlive | Server alive. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.517 | NodesystemDead | Lost connection to server, or server is down. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.518 | NodeautobootChanged | Automatic reboot count has changed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.519 | NodectldevBbuBattTestStart | Battery test has started | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.520 | NodectldevBbuBattTestComplete | Battery test complete | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.521 | NodectldevBbuBattTestCanceled | Battery test canceled | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.522 | NodectldevBbuBattTestFailed | Battery test failed - battery bad | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.640 | NodechannelFailed | Channel Failed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.641 | NodechannelOk | Channel Online. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.642 | NodechannelScsiBusDead | Back end SCSI bus dead. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.643 | NodechannelScsiBusAlive | Back end SCSI bus alive. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.644 | NodechannelFiberDead | Back end fibre dead. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.645 | NodechannelFiberAlive | Back end fibre alive. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.700 | NodelogEmpty | Event log empty. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.701 | NodelogOutSync | Event log entries lost. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.702 | NodelogRequestSense | Request Sense | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.703 | NodelogSetRtc | Set real time clock. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.800 | NodecfgNew | New configuration received. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.801 | NodecfgClear | Configuration cleared. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.802 | NodecfgInvalid | Configuration invalid. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.803 | NodecfgCodAccessError | Configuration on disk access error. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.804 | NodecfgCodConverted | Configuration on disk converted. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.805 | NodecfgCodImportFailed | Configuration on disk import failed. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.806 | NodedebugDumpGenerated | A debug dump exists on this system. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.807 | NodedebugDumpGeneratedPartner | A debug dump exists on this system. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.808 | NodecfgCodNotFound | No valid Configuration On Disk (COD) found. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.809 | NodecfgCodLunMapNotFound | No valid SAN map found in Configuration On Disk (COD) found. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.896 | NodefatalHang | Internal controller hung. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.897 | NodefatalBrkp | Internal controller firmware breakpoint. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.912 | Nodei960HwErr | Internal controller i960 processor error. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.928 | NodesarmHwErr | Internal controller Strong-ARM processor error. | ||
| 1.3.6.1.4.1.1608.1.1.1.9.1.944 | NodescsiHwErr | Internal Controller Backend Hardware Error. | ||
| 1.3.6.1.4.1.1608.1.1.1.10 | TabletBatteryBackupUnitInformation | not-accessible | mandatory | This group provides Battery Backup Unit Information. |
| 1.3.6.1.4.1.1608.1.1.1.10.1 | RoweBatteryBackupUnitInformation | not-accessible | mandatory | |
| 1.3.6.1.4.1.1608.1.1.1.10.1.1 | Columna10ControllerNumber | read-only | mandatory | Controller Number of the controller to which this BBU is connected. |
| 1.3.6.1.4.1.1608.1.1.1.10.1.2 | Columna10OperationalState | read-only | mandatory | Operational state of Battery Backup Unit. |
| 1.3.6.1.4.1.1608.1.1.1.10.1.3 | Columna10BatteryType | read-only | mandatory | Battery Type. |
| 1.3.6.1.4.1.1608.1.1.1.10.1.4 | Columna10CurrentPowerInHours | read-only | mandatory | Current Power in Hours. |
| 1.3.6.1.4.1.1608.1.1.1.10.1.5 | Columna10MaximumPowerInHours | read-only | mandatory | Maximum Power in Hours. |
| 1.3.6.1.4.1.1608.1.1.1.10.1.6 | Columna10ThresholdValueInHours | read-only | mandatory | Threshold Value in Hours. |
| 1.3.6.1.4.1.1608.1.1.1.10.1.7 | Columna10ChargeLevelInPercentage | read-only | mandatory | Battery Charge Level (in percentage). |
| 1.3.6.1.4.1.1608.1.1.1.10.1.8 | Columna10Version | read-only | mandatory | BBU Hardware Version Number. |
| 1.3.6.1.4.1.1608.1.1.1.10.1.9 | Columna10OperationalStateString | read-only | mandatory | BBU Operational State String. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| DmiComponentIndex | INTEGER | ||
| DmiDate | OCTET STRING (SIZE (28)) | ||
| DmiInteger | INTEGER |