MIB Viewer

NCRBSC-OPT-MIB

63 objects
No module-level DESCRIPTION found.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.449Nodecodex
1.3.6.1.4.1.449.2NodecdxProductSpecific
1.3.6.1.4.1.449.2.1Nodecdx6500
1.3.6.1.4.1.449.2.1.2Nodecdx6500Configuration
1.3.6.1.4.1.449.2.1.2.1Nodecdx6500CfgProtocolGroup
1.3.6.1.4.1.449.2.1.2.1.1Nodecdx6500PCTPortProtocolGroup
1.3.6.1.4.1.449.2.1.2.1.1.17Tablecdx6500PPCTNCRBisyncTablenot-accessiblemandatoryA table of NCRBSC Port configuration entries.
1.3.6.1.4.1.449.2.1.2.1.1.17.1Rowcdx6500PPCTNCRBisyncEntrynot-accessiblemandatoryA NCRBSC Configuration Table entry. Each entry contains the configuration parameters for a single NCRBSC port.
1.3.6.1.4.1.449.2.1.2.1.1.17.1.1Columncdx6500NCRBSCCfgPortNumberread-onlymandatoryThe NCRBSC port number described by this entry.
1.3.6.1.4.1.449.2.1.2.1.1.17.1.2Columncdx6500NCRBSCCfgPADTyperead-onlymandatoryIndicates whether the port is functioning as a Terminal PAD (TPAD) or a Host PAD (HPAD). newvalTpad : same functionality as 'tpad', new enumeration added for R…
1.3.6.1.4.1.449.2.1.2.1.1.17.1.3Columncdx6500NCRBSCCfgClockSourceread-onlymandatoryint - internal clock source. ext - external clock source. newvalInt - same functionality as 'int', new enumeration added for RFC1155 compatibility.
1.3.6.1.4.1.449.2.1.2.1.1.17.1.4Columncdx6500NCRBSCCfgClockSpeedread-onlymandatoryThis is the speed of the port in bits per second, when using internal clocking.
1.3.6.1.4.1.449.2.1.2.1.1.17.1.5Columncdx6500NCRBSCCfgContentionread-onlymandatoryIndicates whether Half Duplex (hdx) or Full Duplex (fdx) modem signals are being generated. Full Duplex indicates communication is occuring in both directions …
1.3.6.1.4.1.449.2.1.2.1.1.17.1.6Columncdx6500NCRBSCCfgNumDevicesread-onlymandatorySpecifies the number of physical devices on this line.
1.3.6.1.4.1.449.2.1.2.1.1.17.1.7Columncdx6500NCRBSCCfgServTimerread-onlymandatoryThe Service Timer specifies the interval of time in seconds between periodic servicing. Such servicing includes intervals between the time the PAD will attempt…
1.3.6.1.4.1.449.2.1.2.1.1.17.1.8Columncdx6500NCRBSCCfgErrThreshCountread-onlymandatoryIndicates number of consecutive errors that can occur before a device is considered down.
1.3.6.1.4.1.449.2.1.2.1.1.17.1.10Columncdx6500NCRBSCCfgRetranTimeoutread-onlymandatorySpecifies the amount of time in TENTHS OF A SECOND before a retransmission of the previously sent protocol sequence is attempted. The effective range is 0.1 - …
1.3.6.1.4.1.449.2.1.2.1.1.17.1.11Columncdx6500NCRBSCCfgInterBuffTimeoutread-onlymandatorySpecifies the maximum amount of time in seconds the PAD will wait for the end of a multi-packet message from the network. If this time limit is exceeded, the P…
1.3.6.1.4.1.449.2.1.2.1.1.17.1.12Columncdx6500NCRBSCCfgPortSubAddrread-onlymandatory0 - 3 Decimal digits Calls addressed to this node and with this subaddress will be routed to this port.
1.3.6.1.4.1.449.2.1.2.1.1.17.1.13Columncdx6500NCRBSCCfgPortOptionsread-onlymandatorySelect options on this NCRBSC port as follows: NONE - no option specified ORG - Controllers on this port will originate the calls ACK - DSP End-to-End Acknowle…
1.3.6.1.4.1.449.2.1.2.1.1.17.1.14Columncdx6500NCRBSCCfgRestrictConnDestread-onlymandatory1 - 32 Decimal digits or a single blank All calls originating from this port will be routed to the destination specified in this parameter, irrespective of rou…
1.3.6.1.4.1.449.2.1.2.1.1.17.1.15Columncdx6500NCRBSCCfgBillRecread-onlymandatoryThis controls whether billing (accounting) records will be created for calls on this Device. newvalOff : same functionality as 'off', new enumeration added for…
1.3.6.1.4.1.449.2.1.2.1.1.17.1.16Columncdx6500NCRBSCCfgElectricalInterfaceTyperead-onlymandatorySpecify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 -…
1.3.6.1.4.1.449.2.1.2.1.1.17.1.17Columncdx6500NCRBSCCfgV24ElectricalInterfaceOptionread-onlymandatorySpecify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal
1.3.6.1.4.1.449.2.1.2.1.1.17.1.18Columncdx6500NCRBSCCfgHighSpeedElectricalInterfaceOptionread-onlymandatorySpecify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable
1.3.6.1.4.1.449.2.1.2.1.7Nodecdx6500PCTNCRBSCDeviceGroup
1.3.6.1.4.1.449.2.1.2.1.7.1Tablecdx6500PBCTNCRBSCDeviceTablenot-accessiblemandatoryA table of NCRBSC device configuration entries.
1.3.6.1.4.1.449.2.1.2.1.7.1.1Rowcdx6500PBCTNCRBSCDeviceEntrynot-accessiblemandatoryA NCRBSC Configuration Table entry. Each entry contains the configuration parameters for a single NCRBSC device.
1.3.6.1.4.1.449.2.1.2.1.7.1.1.1Columncdx6500ncrbscDevPortNumberread-onlymandatoryThe NCRBSC port accessing this device
1.3.6.1.4.1.449.2.1.2.1.7.1.1.2Columncdx6500ncrbscDevEntryread-onlymandatoryThe unique number for this specific port.
1.3.6.1.4.1.449.2.1.2.1.7.1.1.3Columncdx6500ncrbscBSCControlUnitAddrread-onlymandatory0-2 Hex digits, This is the Poll address of the Control Unit that supports this device. It consists of two hexadecimal digits. Valid ranges depend on device Ch…
1.3.6.1.4.1.449.2.1.2.1.7.1.1.4Columncdx6500ncrbscDestControlUnitAddrread-onlymandatory0-3 Hex digits, Specifies control unit address on remote PAD. Used with Connection Request Mode = 2 or 3
1.3.6.1.4.1.449.2.1.2.1.7.1.1.5Columncdx6500ncrbscAutocallMnemonicread-onlymandatory0-2 Hex digits, This mnemonic name is used if this device is configured for AUTO or FAST calling.
1.3.6.1.4.1.449.2.1.2.1.7.1.1.6Columncdx6500ncrbscDeviceEnabledread-onlymandatoryThis parameter is used to enable or disable the operation of this controller device. yes - Enable device. no - Disable device. newvalNo - same functionality as…
1.3.6.1.4.1.449.2.1.3Nodecdx6500Statistics
1.3.6.1.4.1.449.2.1.3.1Nodecdx6500StatProtocolGroup
1.3.6.1.4.1.449.2.1.3.1.1Nodecdx6500PSTPortProtocolGroup
1.3.6.1.4.1.449.2.1.3.1.1.17Tablecdx6500PPSTNCRBisyncTablenot-accessiblemandatoryA table of NCRBSC port statistics entries.
1.3.6.1.4.1.449.2.1.3.1.1.17.1Rowcdx6500ncrbscPortStatEntrynot-accessiblemandatoryA NCRBSC Port Statistic Table entry. Each entry contains the statistics for a single NCRBSC port.
1.3.6.1.4.1.449.2.1.3.1.1.17.1.1Columncdx6500ncrbscStatPortNumberread-onlymandatoryThe NCRBSC port number described by this entry.
1.3.6.1.4.1.449.2.1.3.1.1.17.1.2Columncdx6500ncrbscPortStatusread-onlymandatoryPort Status indicates whether or not the port is switched on and is ready for operation. This value may be one of : up - Port is up and running. down - port is…
1.3.6.1.4.1.449.2.1.3.1.1.17.1.3Columncdx6500ncrbscPortStateread-onlymandatoryPort State indicates what the port is actually in the process of doing. This value may be one of : INACTIVE - H/TPAD port inactive entered during boot. WTPOLSE…
1.3.6.1.4.1.449.2.1.3.1.1.17.1.4Columncdx6500ncrbscPortSpeedread-onlymandatoryThis is the speed of the port if clock is internal. If clock is external, this is the detected clock speed. If Port Speed is 0, clock is external, but clocking…
1.3.6.1.4.1.449.2.1.3.1.1.17.1.5Columncdx6500ncrbscPortUtilInread-onlymandatoryPercentage of port input bandwidth in use.
1.3.6.1.4.1.449.2.1.3.1.1.17.1.6Columncdx6500ncrbscPortUtilOutread-onlymandatoryPercentage of Port output bandwidth in use.
1.3.6.1.4.1.449.2.1.3.1.1.17.1.7Columncdx6500ncrbscInMsgsread-onlymandatoryNumber of message received since last node, port, or statistics reset.
1.3.6.1.4.1.449.2.1.3.1.1.17.1.8Columncdx6500ncrbscOutMsgsread-onlymandatoryNumber of message sent since last node, port, or statistics reset.
1.3.6.1.4.1.449.2.1.3.1.1.17.1.9Columncdx6500ncrbscInCharsread-onlymandatoryNumber of characters received since last node, port, or statistics reset.
1.3.6.1.4.1.449.2.1.3.1.1.17.1.10Columncdx6500ncrbscOutCharsread-onlymandatoryNumber of characters sent since last node, port, or statistics reset.
1.3.6.1.4.1.449.2.1.3.1.1.17.1.11Columncdx6500ncrbscCharRateInread-onlymandatoryNumber of characters received per second.
1.3.6.1.4.1.449.2.1.3.1.1.17.1.12Columncdx6500ncrbscCharRateOutread-onlymandatoryNumber of characters sent per second.
1.3.6.1.4.1.449.2.1.3.1.1.17.1.13Columncdx6500ncrbscCrcBccErrsread-onlymandatoryNumber of CRC errors since last node, port, or statistics reset.
1.3.6.1.4.1.449.2.1.3.1.1.17.1.14Columncdx6500ncrbscRviRxread-onlymandatoryAccumulator, received RVI.
1.3.6.1.4.1.449.2.1.3.1.1.17.1.15Columncdx6500ncrbscRviTxread-onlymandatoryAccumulator, transmitted RVI.
1.3.6.1.4.1.449.2.1.3.1.1.17.1.16Columncdx6500ncrbscWackRxread-onlymandatoryAccumulator, recevied WACK.
1.3.6.1.4.1.449.2.1.3.1.1.17.1.17Columncdx6500ncrbscNconvRxMaxread-onlymandatoryMaximum number of conversation messages received from device within a poll or select.
1.3.6.1.4.1.449.2.1.3.1.1.17.1.18Columncdx6500ncrbscNconvTxMaxread-onlymandatoryMaximum number of conversation messages sent to device within a poll or select.
1.3.6.1.4.1.449.2.1.3.1.1.17.1.19Columncdx6500ncrbscNgroupRxMaxread-onlymandatoryMaximum number of grouping messages received from device within a poll or select.
1.3.6.1.4.1.449.2.1.3.1.1.17.1.20Columncdx6500ncrbscNgroupTxMaxread-onlymandatoryMaximum number of grouping messages sent to device within a poll or select.
1.3.6.1.4.1.449.2.1.3.1.1.17.1.21Columncdx6500ncrbscLongRespTimeread-onlymandatoryLongest response time
1.3.6.1.4.1.449.2.1.3.1.1.17.1.22Columncdx6500ncrbscAverageRespTimeread-onlymandatoryAverage response time
1.3.6.1.4.1.449.2.1.3.1.1.17.1.23Columncdx6500ncrbscRviForceread-onlymandatoryNumber of RVI's sent to device from the polling algorithm.
Type Definitions
NameSyntaxStatusDescription
DisplayStringOCTET STRING