MIB Viewer

NETEXEC-MIB

311 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1Nodeinternet
1.3.6.1.4Nodeprivate
1.3.6.1.4.1Nodeenterprises
1.3.6.1.4.1.466Nodetylink
1.3.6.1.4.1.466.6Nodenetexec
1.3.6.1.4.1.466.6.1Nodedsucsu
1.3.6.1.4.1.466.6.1.0NodedsucsuTrapA dsucsuTrap trap signifies that the sending node had its `dsucsuAlarmType` variable modified.
1.3.6.1.4.1.466.6.1.1TabledsucsuSysTablenot-accessiblemandatoryA list of system level attributes describing the addressed node.
1.3.6.1.4.1.466.6.1.1.1RowdsucsuSysEntrynot-accessiblemandatorySystem Object for a DSU/CSU
1.3.6.1.4.1.466.6.1.1.1.1ColumndsucsuSysSlotread-onlymandatoryThe PC port to which the TyView node is attached.
1.3.6.1.4.1.466.6.1.1.1.2ColumndsucsuSysNoderead-onlymandatoryThe node ID: unique per port ID.
1.3.6.1.4.1.466.6.1.1.1.3ColumndsucsuSysNameread-onlymandatoryThe unique name of the node accessed
1.3.6.1.4.1.466.6.1.1.1.4ColumndsucsuSysTyperead-onlymandatoryA desciption of the system model: ie. ONS400, FNS400, ONS1000X, BLACK BOX FT1-4
1.3.6.1.4.1.466.6.1.1.1.5ColumndsucsuSysSoftRevread-onlymandatoryDisplays the Software Revision of the accessed node.
1.3.6.1.4.1.466.6.1.1.1.6ColumndsucsuSysHardRevread-onlymandatoryDisplays the Hardware Revision of the accessed node.
1.3.6.1.4.1.466.6.1.1.1.7ColumndsucsuSysNumChanread-onlymandatoryThe number of channels that are installed on the node.
1.3.6.1.4.1.466.6.1.2TabledsucsuCfgNetTablenot-accessiblemandatoryNetwork Line Configuration
1.3.6.1.4.1.466.6.1.2.1RowdsucsuCfgNetEntrynot-accessiblemandatoryConfiguration Object for a DSU/CSU
1.3.6.1.4.1.466.6.1.2.1.1ColumndsucsuCfgNetSlotread-onlymandatoryThe NEST slot to which the TyLink card is attached.
1.3.6.1.4.1.466.6.1.2.1.2ColumndsucsuCfgNetNoderead-onlymandatoryThe node ID: unique per port ID.
1.3.6.1.4.1.466.6.1.2.1.3ColumndsucsuCfgNetIndexread-onlymandatoryThe network index.
1.3.6.1.4.1.466.6.1.2.1.4ColumndsucsuCfgNetInterfaceread-writemandatoryThe interface type for 3000N. For a T1 line, NETWORK or DSX-1 is valid.
1.3.6.1.4.1.466.6.1.2.1.5ColumndsucsuCfgNetTyperead-writemandatoryThe aggregate line type.
1.3.6.1.4.1.466.6.1.2.1.6ColumndsucsuCfgNetCodingread-writemandatoryThe encoding scheme for the line. For a T1 line, AMI and B8ZS are valid. For an E1 line, AMI and HDB3 are valid.
1.3.6.1.4.1.466.6.1.2.1.7ColumndsucsuCfgNetClockSourceread-writemandatoryThe aggregate timing for the addressed node.
1.3.6.1.4.1.466.6.1.2.1.8ColumndsucsuCfgNetCsuEnableread-writemandatoryEnable/Disable Internal CSU.
1.3.6.1.4.1.466.6.1.2.1.9ColumndsucsuCfgNetCsuLBOread-writemandatoryThe setting of the Line Buildout switch. Setting must be db_0 if network interface is DSX-1.
1.3.6.1.4.1.466.6.1.2.1.10ColumndsucsuCfgNetCsuDensityread-writemandatoryThe setting of the one stuffing option. Inserts a 1 into the 8th, 16th, or 64th bit position (depending on the selection) if the previous 7 bits were 0's.
1.3.6.1.4.1.466.6.1.2.1.11ColumndsucsuCfgNetRateMultiplesread-writemandatoryThe channel rate multiples for each of the ports.
1.3.6.1.4.1.466.6.1.2.1.12ColumndsucsuCfgNetOutputPulseread-writemandatoryThe distance to the CSU in feet.
1.3.6.1.4.1.466.6.1.2.1.13ColumndsucsuCfgNetTs0read-writemandatoryThe E1 Timeslot 0 value.
1.3.6.1.4.1.466.6.1.2.1.14ColumndsucsuCfgNetTs16read-writemandatoryThe E1 Timeslot 16 value. Valid values are data and multiframe alignment.
1.3.6.1.4.1.466.6.1.4TabledsucsuCfgDteChanTablenot-accessiblemandatoryDTE Channel Configuration
1.3.6.1.4.1.466.6.1.4.1RowdsucsuCfgDteChanEntrynot-accessiblemandatoryDTE Channel Configuration Object for a DSU/CSU
1.3.6.1.4.1.466.6.1.4.1.1ColumndsucsuCfgDteChanSlotread-onlymandatoryThe PC port to which the TyView node is attached.
1.3.6.1.4.1.466.6.1.4.1.2ColumndsucsuCfgDteChanNoderead-onlymandatoryThe node ID: unique per port ID.
1.3.6.1.4.1.466.6.1.4.1.3ColumndsucsuCfgDteChanIndexread-onlymandatoryThe channel index.
1.3.6.1.4.1.466.6.1.4.1.4ColumndsucsuCfgDteChanTyperead-writemandatoryThe Dte channel type.
1.3.6.1.4.1.466.6.1.4.1.5ColumndsucsuCfgDteChanRateread-writemandatoryThe Data rate in kilobits per second. The rate is dependent on the setting of the Aggregate DTE channel multiples.
1.3.6.1.4.1.466.6.1.4.1.6ColumndsucsuCfgDteChanEncodingread-writemandatoryThe Channel encoding.
1.3.6.1.4.1.466.6.1.4.1.7ColumndsucsuCfgDteChanStartDs0read-writemandatoryThe starting DS0 for the addressed channel's data.
1.3.6.1.4.1.466.6.1.4.1.8ColumndsucsuCfgDteChanCtrlSignalread-writemandatoryThe control signal state.
1.3.6.1.4.1.466.6.1.4.1.9ColumndsucsuCfgDteChanTimingread-writemandatoryThe DTE channel Timing.
1.3.6.1.4.1.466.6.1.4.1.10ColumndsucsuCfgDteChanClockInvertread-writemandatoryThe DTE channel Clock Invert setting.
1.3.6.1.4.1.466.6.1.4.1.11ColumndsucsuCfgDteChanDataInvertread-writemandatoryThe DTE channel Data Invert setting.
1.3.6.1.4.1.466.6.1.5TabledsucsuCfgFrmChanTablenot-accessiblemandatoryFramed Channel Configuration
1.3.6.1.4.1.466.6.1.5.1RowdsucsuCfgFrmChanEntrynot-accessiblemandatoryFramed Channel Configuration Object for a DSU/CSU
1.3.6.1.4.1.466.6.1.5.1.1ColumndsucsuCfgFrmChanSlotread-onlymandatoryThe PC port to which the TyView node is attached.
1.3.6.1.4.1.466.6.1.5.1.2ColumndsucsuCfgFrmChanNoderead-onlymandatoryThe node ID: unique per port ID.
1.3.6.1.4.1.466.6.1.5.1.3ColumndsucsuCfgFrmChanIndexread-onlymandatoryThe channel index.
1.3.6.1.4.1.466.6.1.5.1.4ColumndsucsuCfgFrmChanTyperead-onlymandatoryThe framed channel type.
1.3.6.1.4.1.466.6.1.5.1.5ColumndsucsuCfgFrmChanNumDs0read-writemandatoryThe number of DS0's on the network side.
1.3.6.1.4.1.466.6.1.5.1.6ColumndsucsuCfgFrmChanEncodingread-writemandatoryThe channel line code.
1.3.6.1.4.1.466.6.1.5.1.7ColumndsucsuCfgFrmChanStartDs0read-writemandatoryThe starting DS0 on the network side.
1.3.6.1.4.1.466.6.1.5.1.8ColumndsucsuCfgFrmChanDteStartDs0read-writemandatoryThe starting DS0 on the framed channel.
1.3.6.1.4.1.466.6.1.5.1.9ColumndsucsuCfgFrmChanMappingread-writemandatoryThe Framed channel Mapping.
1.3.6.1.4.1.466.6.1.5.1.10ColumndsucsuCfgFrmChanDs0Typeread-writemandatoryThe Framed channel DS0 Type.
1.3.6.1.4.1.466.6.1.5.1.11ColumndsucsuCfgFrmChanFrameTyperead-writemandatoryThe Framed channel Frame Type.
1.3.6.1.4.1.466.6.1.5.1.12ColumndsucsuCfgFrmChanOutputPulseread-writemandatoryThe cabling distance from the PBX to the PBX channel port in feet.
1.3.6.1.4.1.466.6.1.5.1.13ColumndsucsuCfgFrmChanNetMappingread-writemandatoryThe Network Ds0 Mapping.
1.3.6.1.4.1.466.6.1.7TabledsucsuConfigSupTablenot-accessiblemandatoryInband Supervisory Channel Configuration
1.3.6.1.4.1.466.6.1.7.1RowdsucsuConfigSupEntrynot-accessiblemandatoryInband Supervisory Configuration Object for a DSU/CSU
1.3.6.1.4.1.466.6.1.7.1.1ColumndsucsuConfigSupSlotread-onlymandatoryThe PC port to which the TyView node is attached.
1.3.6.1.4.1.466.6.1.7.1.2ColumndsucsuConfigSupNoderead-onlymandatoryThe node ID: unique per port ID.
1.3.6.1.4.1.466.6.1.7.1.3ColumndsucsuConfigSupIndexread-onlymandatoryThe Supervisory channel index. Index 1 refers to supervisory channel A. Index 2 refers to supervisory channel B.
1.3.6.1.4.1.466.6.1.7.1.4ColumndsucsuConfigSupDs0read-writemandatoryThe DS0 to place the Supervisory channel in.
1.3.6.1.4.1.466.6.1.8TabledsucsuCfgSupAuxTablenot-accessiblemandatoryAuxillary Supervisory Channel Configuration
1.3.6.1.4.1.466.6.1.8.1RowdsucsuCfgSupAuxEntrynot-accessiblemandatoryAuxilary Supervisory Configuration Object for a DSU/CSU
1.3.6.1.4.1.466.6.1.8.1.1ColumndsucsuCfgSupAuxSlotread-onlymandatoryThe PC port to which the TyView node is attached.
1.3.6.1.4.1.466.6.1.8.1.2ColumndsucsuCfgSupAuxNoderead-onlymandatoryThe node ID: unique per port ID.
1.3.6.1.4.1.466.6.1.8.1.3ColumndsucsuCfgSupAuxIndexread-onlymandatoryAuxillary Supervisory Channel Configuration Index Index 1 refers to FDL supervisory on PORT 1. Index 2 refers to FDL supervisory on PORT 2.
1.3.6.1.4.1.466.6.1.8.1.4ColumndsucsuCfgSupAuxFdlread-writemandatoryPlaces the supervisory link bits within the Facility Data Link bits of the Extended Superframe.
1.3.6.1.4.1.466.6.1.9TabledsucsuActvConfTablenot-accessiblemandatoryActivate a stored configuration on the selected node.
1.3.6.1.4.1.466.6.1.9.1RowdsucsuActvConfEntrynot-accessiblemandatoryAn activate configuration entry.
1.3.6.1.4.1.466.6.1.9.1.1ColumndsucsuActvConfSlotread-onlymandatoryThe PC port to which the TyView node is attached.
1.3.6.1.4.1.466.6.1.9.1.2ColumndsucsuActvConfNoderead-onlymandatoryThe node ID: unique per port ID.
1.3.6.1.4.1.466.6.1.9.1.3ColumndsucsuActvConfIndexwrite-onlymandatoryActivate one of the four stored configurations.
1.3.6.1.4.1.466.6.1.10TabledsucsuEventDesTablenot-accessiblemandatoryTable of event destinations. Events or alarms detected by a node can be reported to up to two destinations. The operator can set or clear either or both of the…
1.3.6.1.4.1.466.6.1.10.1RowdsucsuEventDesEntrynot-accessiblemandatoryEntry in the table of event destinations.
1.3.6.1.4.1.466.6.1.10.1.1ColumndsucsuEventDesSlotread-onlymandatoryThe PC port to which the TyView node is attached.
1.3.6.1.4.1.466.6.1.10.1.2ColumndsucsuEventDesNoderead-onlymandatoryThe node ID: unique per port ID.
1.3.6.1.4.1.466.6.1.10.1.3ColumndsucsuEventNameIndxread-onlymandatoryThe unique name of the node accessed.
1.3.6.1.4.1.466.6.1.10.1.4ColumndsucsuEventDesName1read-writemandatoryThe name of the node/PC where the alarms will be sent to.
1.3.6.1.4.1.466.6.1.10.1.5ColumndsucsuEventDesName2read-writemandatoryThe name of the alternate node/PC where the alarms will be sent to.
1.3.6.1.4.1.466.6.1.10.1.6ColumndsucsuEventClrDestwrite-onlymandatoryClears the destination(s) for the reporting of alarms.
1.3.6.1.4.1.466.6.1.11TabledsucsuCfgMaintTablenot-accessiblemandatoryMaint. Port Configuration
1.3.6.1.4.1.466.6.1.11.1RowdsucsuCfgMaintEntrynot-accessiblemandatoryMaint. Port Configuration Object
1.3.6.1.4.1.466.6.1.11.1.1ColumndsucsuCfgMaintSlotread-onlymandatoryThe PC port to which the TyView node is attached.
1.3.6.1.4.1.466.6.1.11.1.2ColumndsucsuCfgMaintNoderead-onlymandatoryThe node ID: unique per port ID.
1.3.6.1.4.1.466.6.1.11.1.3ColumndsucsuCfgMaintChanTyperead-writemandatoryThe type of data passed over the Maint. port.
1.3.6.1.4.1.466.6.1.11.1.4ColumndsucsuCfgMaintFlowCtrlread-writemandatoryFlow Control for the Maint. port.
1.3.6.1.4.1.466.6.1.11.1.5ColumndsucsuCfgMaintStopBitsread-writemandatoryNumber of Stopbits for the Maint. port.
1.3.6.1.4.1.466.6.1.11.1.6ColumndsucsuCfgMaintParityread-writemandatoryParity for the Maint. port.
1.3.6.1.4.1.466.6.1.11.1.7ColumndsucsuCfgMaintDataBitsread-writemandatoryDatabits for the Maint. port.
1.3.6.1.4.1.466.6.1.11.1.8ColumndsucsuCfgMaintBaudread-writemandatoryBaud rate for the Maint. port.
1.3.6.1.4.1.466.6.1.12TabledsucsuCfgCommTablenot-accessiblemandatoryCommunication Port Configuration
1.3.6.1.4.1.466.6.1.12.1RowdsucsuCfgCommEntrynot-accessiblemandatoryCommunication Port Configuration Object
1.3.6.1.4.1.466.6.1.12.1.1ColumndsucsuCfgCommSlotread-onlymandatoryThe PC port to which the TyView node is attached.
1.3.6.1.4.1.466.6.1.12.1.2ColumndsucsuCfgCommNoderead-onlymandatoryThe node ID: unique per port ID.
1.3.6.1.4.1.466.6.1.12.1.3ColumndsucsuCfgCommChanTyperead-writemandatoryThe type of data passed over the Communication port.
1.3.6.1.4.1.466.6.1.12.1.4ColumndsucsuCfgCommFlowCtrlread-writemandatoryFlow Control for the Communication port.
1.3.6.1.4.1.466.6.1.12.1.5ColumndsucsuCfgCommStopBitsread-writemandatoryNumber of Stopbits for the Communication port.
1.3.6.1.4.1.466.6.1.12.1.6ColumndsucsuCfgCommParityread-writemandatoryParity for the Communication port.
1.3.6.1.4.1.466.6.1.12.1.7ColumndsucsuCfgCommDataBitsread-writemandatoryDatabits for the Communication port.
1.3.6.1.4.1.466.6.1.12.1.8ColumndsucsuCfgCommBaudread-writemandatoryBaud rate for the Communication port.
1.3.6.1.4.1.466.6.1.13TabledsucsuCfgBrdTablenot-accessiblemandatoryNetwork timing for 3000N board.
1.3.6.1.4.1.466.6.1.13.1RowdsucsuCfgBrdEntrynot-accessiblemandatoryBoard Timing Configuration Object.
1.3.6.1.4.1.466.6.1.13.1.1ColumndsucsuCfgBrdSlotread-onlymandatoryThe PC port to which the TyView node is attached.
1.3.6.1.4.1.466.6.1.13.1.2ColumndsucsuCfgBrdNoderead-onlymandatoryThe node ID: unique per port ID.
1.3.6.1.4.1.466.6.1.13.1.3ColumndsucsuCfgBrdTimingread-writemandatoryThe Board Level Timing for a 3000N.
1.3.6.1.4.1.466.6.1.14NodedsucsuCfgDacsTable
1.3.6.1.4.1.466.6.1.14.1TabledsucsuCfgAutoAssignTablenot-accessiblemandatoryAutomatically assign the proper amount of bandwidth.
1.3.6.1.4.1.466.6.1.14.1.1RowdsucsuCfgAutoAssignEntrynot-accessiblemandatoryDACS auto assign Configuration Object.
1.3.6.1.4.1.466.6.1.14.1.1.1ColumndsucsuConnAutoSlotread-onlymandatoryThe PC port to which the TyView node is attached.
1.3.6.1.4.1.466.6.1.14.1.1.2ColumndsucsuConnAutoNoderead-onlymandatoryThe node ID: unique per port ID.
1.3.6.1.4.1.466.6.1.14.1.1.3ColumndsucsuConnAutoSrcPortread-onlymandatoryIndex to the 3000N source port of interest. 3000N supports two DTE-V35/RS-499 DATA ports (P3-P4).
1.3.6.1.4.1.466.6.1.14.1.1.4ColumndsucsuConnAutoStartDS0read-writemandatoryPort1/2 includes 24 DS0's. This value is the starting DS0 used by the node to allocate DS0s to meet port(3-4)-dte requirements. Sequential, contiguous DS0s are…
1.3.6.1.4.1.466.6.1.14.1.1.5ColumndsucsuConnAutoDestPortread-writemandatorySelects the port for which DS0s are automatically allocated to one of the T1 network ports. Node software may not allow connection of port1 to port1.
1.3.6.1.4.1.466.6.1.14.1.1.6ColumndsucsuConnAutoTyperead-writemandatoryDefines the type of traffic being transported. The 3000N supports data (1) or voice (2). The selected type will be assigned to all DS0s.
1.3.6.1.4.1.466.6.1.14.1.1.7ColumndsucsuConnDteRateread-onlymandatoryData rate of the DTE port. Can be chaged from the CfgDteTable.
1.3.6.1.4.1.466.6.1.14.1.1.8ColumndsucsuConnDteDensityread-onlymandatoryChannel/DS0 format for the DTE port. Can be changed from the CfgDteTable.
1.3.6.1.4.1.466.6.1.14.1.1.9ColumndsucsuConnDs0Requiredread-onlymandatoryThe number of DS0s required by the node's DTE port. This is based upon the DTE data rate and channel density selections.
1.3.6.1.4.1.466.6.1.14.1.1.10ColumndsucsuConnAutoStatusread-onlymandatoryQueries the node's connection status. Code will be returned when a connection set or update is rejected or accepted.
1.3.6.1.4.1.466.6.1.14.1.1.11ColumndsucsuConnAutoUpdateCmdwrite-onlymandatoryUpdates the connections with the edit buffer. The edit buffer is comprised of any changes sent (set) from the dsucsuCfgAutoAssignEntry.
1.3.6.1.4.1.466.6.1.14.2TabledsucsuCfgCurrentConnTablenot-accessiblemandatoryRetrieves node's active connections assignments for display only. To edit connections, use CfgConnAutoAssign or CfgEditConnTable.
1.3.6.1.4.1.466.6.1.14.2.1RowdsucsuCfgCurrentConnectionsnot-accessiblemandatoryAn entry in the Current Connections Table.
1.3.6.1.4.1.466.6.1.14.2.1.1ColumndsucsuSlotread-onlymandatoryThe PC port to which the TyView node is attached.
1.3.6.1.4.1.466.6.1.14.2.1.2ColumndsucsuNoderead-onlymandatoryThe node ID: unique per port ID.
1.3.6.1.4.1.466.6.1.14.2.1.3ColumndsucsuT1Indexread-onlymandatoryIndex to T1 network port of interest. The 3000N supports two NETWORK/DSX-1 ports.
1.3.6.1.4.1.466.6.1.14.2.1.4ColumndsucsuDs0read-onlymandatoryDS0 number 1 through 24 corresponding to the T1 network port index.
1.3.6.1.4.1.466.6.1.14.2.1.5ColumndsucsuDtePortread-onlymandatoryDS0 assignment for indexed T1 network port. After making any adjustments to the connections, the dsucsuCfgConnUpdateCmd must be sent. Node software may not per…
1.3.6.1.4.1.466.6.1.14.2.1.6ColumndsucsuTyperead-onlymandatoryDefines the type of traffic being transported. The 3000N supports data (1) or voice (2).
1.3.6.1.4.1.466.6.1.14.3TabledsucsuCfgEditConnTablenot-accessiblemandatoryManually assign the proper amount of bandwidth.
1.3.6.1.4.1.466.6.1.14.3.1RowdsucsuCfgEditConnEntrynot-accessiblemandatoryEdits current DS0 assignment. After making any adjustments to the connections, the dsucsuCfgConnUpdateCmd must be sent.
1.3.6.1.4.1.466.6.1.14.3.1.1ColumndsucsuConnSlotread-onlymandatoryThe PC port to which the TyView node is attached.
1.3.6.1.4.1.466.6.1.14.3.1.2ColumndsucsuConnNoderead-onlymandatoryThe node ID: unique per port ID.
1.3.6.1.4.1.466.6.1.14.3.1.3ColumndsucsuConnSrcPortread-onlymandatoryIndex to the source port of interest. The 3000N supports two NETWORK/DSX-1 and two DTE ports.
1.3.6.1.4.1.466.6.1.14.3.1.4ColumndsucsuConnSrcDs0read-onlymandatoryThe source DS0 number 1 through 24 corresponding to the T1 network port index
1.3.6.1.4.1.466.6.1.14.3.1.5ColumndsucsuConnDestPortread-writemandatoryIndex to the destination port of interest. The 3000N supports two NETWORK/DSX-1 and two DTE ports.
1.3.6.1.4.1.466.6.1.14.3.1.6ColumndsucsuConnDestDs0read-writemandatoryDS0 assignment for indexed T1 network port. After making any adjustments to the connections, the dsucsuConnUpdateCmd must be sent. Node software may not permit…
1.3.6.1.4.1.466.6.1.14.3.1.7ColumndsucsuConnTyperead-writemandatoryDefines the type of traffic being transported. The 3000N supports data (1) or voice (2).
1.3.6.1.4.1.466.6.1.14.3.1.8ColumndsucsuConnNumDs0sread-writemandatoryThe total number of Ds0s to be connected. The number of Ds0s must be between 1 and 24.
1.3.6.1.4.1.466.6.1.14.3.1.9ColumndsucsuConnSetStatusread-onlymandatoryDisplays node status from the last SNMP issed set command.
1.3.6.1.4.1.466.6.1.14.3.1.10ColumndsucsuConnConnectwrite-onlymandatoryUpdates the connections with the edit buffer. The edit buffer is comprised of any changes sent (set) from the CfgEditConnTable.
1.3.6.1.4.1.466.6.1.14.3.1.11ColumndsucsuConnUpdateRequiredread-onlymandatoryDisplays node status from the last connection update.
1.3.6.1.4.1.466.6.1.14.3.1.12ColumndsucsuConnUpdateCmdwrite-onlymandatorySends the updated connections from the edit buffer to the node. The edit buffer is comprised of any changes sent (set) from the CfgEditConnTable.
1.3.6.1.4.1.466.6.1.14.3.1.13ColumndsucsuConnClearEditBuffwrite-onlymandatoryRemoves all changes from edit buffer. The edit buffer is comprised of any changes sent (set) from the CfgEditConnTable.
1.3.6.1.4.1.466.6.1.15TabledsucsuDiagNetTablenot-accessiblemandatoryA list of Network Diagnostic attributes. Loopbacks, tests and their respective results can be initiated, cancelled and examined.
1.3.6.1.4.1.466.6.1.15.1RowdsucsuDiagNetEntrynot-accessiblemandatoryA Network Diagnostic entry
1.3.6.1.4.1.466.6.1.15.1.1ColumndsucsuDiagNetSlotread-onlymandatoryThe PC port to which the TyView node is attached.
1.3.6.1.4.1.466.6.1.15.1.2ColumndsucsuDiagNetNoderead-onlymandatoryThe node ID: unique per port ID.
1.3.6.1.4.1.466.6.1.15.1.3ColumndsucsuDiagNetIndexread-onlymandatoryThe network number to be examined for a particular node (3000N only).
1.3.6.1.4.1.466.6.1.15.1.4ColumndsucsuDiagNetLclNetAggLpbkread-writemandatoryEnables the operator to control and examine the local aggregate loopback. This loopback occurs on the net side of the local transmit and receive logic. The uni…
1.3.6.1.4.1.466.6.1.15.1.5ColumndsucsuDiagNetLclNetLpbkread-writemandatoryEnables the operator to control and examine the local network loopback. This loopback allows the operator to disconnect the side of the network by transmitting…
1.3.6.1.4.1.466.6.1.15.1.6ColumndsucsuDiagNetLclNetPayloadread-writemandatoryEnables the operator to control and examine the network payload loopback. This loopback occurs on the net side of the local transmit and receive logic. The uni…
1.3.6.1.4.1.466.6.1.15.1.7ColumndsucsuDiagNetLclNetBiDirread-writemandatoryEnables the operator to control and examine the local network loopback. This loopback allows the operator to disconnect the side of the network by transmitting…
1.3.6.1.4.1.466.6.1.15.1.8ColumndsucsuDiagNetRemCsuLpbkread-writemandatoryEnables the operator to control and examine the remote CSU loopback. This loopback allows the operator to test the operation of the local channel, the aggregat…
1.3.6.1.4.1.466.6.1.15.1.9ColumndsucsuDiagNetRemDsuLpbkread-writemandatoryEnables the operator to control and examine the remote aggregate loopback. This loopback allows the operator to test the entire system from the local unit thro…
1.3.6.1.4.1.466.6.1.15.1.10ColumndsucsuDiagNetEvElapTimeread-onlymandatoryThe time elapsed since the Event Test started. The new Event Test commences as soon as the previous Event Test registers are cleared.
1.3.6.1.4.1.466.6.1.15.1.11ColumndsucsuDiagNetEvCRC6Errread-onlymandatoryThe number of CRC6 errors encountered during the Event Test period.
1.3.6.1.4.1.466.6.1.15.1.12ColumndsucsuDiagNetEvOofErrread-onlymandatoryThe number of Out-Of-Frame errors encountered during the Event Test period.
1.3.6.1.4.1.466.6.1.15.1.13ColumndsucsuDiagNetErrEventsread-onlymandatoryThe number of Errored Events encountered during the Event Test period.
1.3.6.1.4.1.466.6.1.15.1.14ColumndsucsuDiagNetClearEvRegwrite-onlymandatoryClear all the Event Test registers. Automatically initiates a new Event Test.
1.3.6.1.4.1.466.6.1.16TabledsucsuDiagDteTablenot-accessiblemandatoryA list of DTE channel diagnostics.
1.3.6.1.4.1.466.6.1.16.1RowdsucsuDiagDteEntrynot-accessiblemandatoryA DTE channel diagnostic entry
1.3.6.1.4.1.466.6.1.16.1.1ColumndsucsuDiagDteSlotread-onlymandatoryThe PC port to which the TyView node is attached.
1.3.6.1.4.1.466.6.1.16.1.2ColumndsucsuDiagDteNoderead-onlymandatoryThe node ID: unique per port ID.
1.3.6.1.4.1.466.6.1.16.1.3ColumndsucsuDiagDteIndexread-onlymandatoryThe channel number to be examined for a particular node.
1.3.6.1.4.1.466.6.1.16.1.4ColumndsucsuDiagDteLocalBiDirread-writemandatoryThis selection displays the status or controls the Local Channel Loopback for the selected channel. This is a local turnaround and is bi-directional.
1.3.6.1.4.1.466.6.1.16.1.5ColumndsucsuDiagDteLocalPayloadread-writemandatoryThis selection displays the status or controls the Local Payload Channel Loopback for the selected channel.
1.3.6.1.4.1.466.6.1.16.1.6ColumndsucsuDiagDteRemLpbkread-writemandatoryThis selection displays the status or controls the Channel Remote Loopback for the selected channel. This loopback transmits a code to the remote node which wi…
1.3.6.1.4.1.466.6.1.16.1.7ColumndsucsuDiagDteBertTestActread-writemandatoryBERT test related actions: a: Starts a BERT test on a channel, b: Stops a BERT test on a channel, c: Inject Errors while the BERT test is running, d: Clears BE…
1.3.6.1.4.1.466.6.1.16.1.8ColumndsucsuDiagDteBertHourStrtread-onlymandatoryDisplays the hour that the BERT test started.
1.3.6.1.4.1.466.6.1.16.1.9ColumndsucsuDiagDteBertMinStrtread-onlymandatoryDisplays th minute that BERT test started.
1.3.6.1.4.1.466.6.1.16.1.10ColumndsucsuDiagDteBertTimeElapsread-onlymandatoryElapsed time since the BERT Test started
1.3.6.1.4.1.466.6.1.16.1.11ColumndsucsuDiagDteBertErrorsread-onlymandatoryNumber of BERT test errors encountered during the BERT Test.
1.3.6.1.4.1.466.6.1.17TabledsucsuDiagFrmTablenot-accessiblemandatoryA list of framed channel diagnostics.
1.3.6.1.4.1.466.6.1.17.1RowdsucsuDiagFrmEntrynot-accessiblemandatoryA framed channel diagnostic entry
1.3.6.1.4.1.466.6.1.17.1.1ColumndsucsuDiagFrmSlotread-onlymandatoryThe PC port to which the TyView node is attached.
1.3.6.1.4.1.466.6.1.17.1.2ColumndsucsuDiagFrmNoderead-onlymandatoryThe node ID: unique per port ID.
1.3.6.1.4.1.466.6.1.17.1.3ColumndsucsuDiagFrmIndexread-onlymandatoryThe channel number to be examined for a particular node.
1.3.6.1.4.1.466.6.1.17.1.4ColumndsucsuDiagFrmLclLpbkread-writemandatoryThis selection displays the status or controls the Local Channel Loopback for the selected channel. This is a local turnaround and is bi-directional.
1.3.6.1.4.1.466.6.1.17.1.5ColumndsucsuDiagFrmLclPayloadread-writemandatoryThis selection displays the status or controls the Channel Remote Loopback for the selected channel. This loopback transmits a code to the remote node which wi…
1.3.6.1.4.1.466.6.1.17.1.6ColumndsucsuDiagFrmLclBiDirread-writemandatoryThis selection displays the status or controls the DSX Loopback for the selected channel. This selection is applicable only for DSX channels.
1.3.6.1.4.1.466.6.1.17.1.7ColumndsucsuDiagFrmRemLpbkread-writemandatoryThis selection displays the status or controls the Local Channel Loopback for the selected channel. This loopback transmits a code to the remote node which wil…
1.3.6.1.4.1.466.6.1.17.1.8ColumndsucsuDiagFrmLclDteread-writemandatoryThis selection displays the status or controls the Local Channel Loopback for the selected channel. This is a local turnaround and is bi-directional. This sele…
1.3.6.1.4.1.466.6.1.17.1.9ColumndsucsuDiagFrmLclDte2read-writemandatoryThis selection displays the status or controls the Channel Remote Loopback for the selected channel. This loopback transmits a code to the remote node which wi…
1.3.6.1.4.1.466.6.1.17.1.10ColumndsucsuDiagFrmBertTestActread-writemandatoryBERT test related actions: a: Starts a BERT test on a channel, b: Stops a BERT test on a channel, c: Inject Errors while the BERT test is running, d: Clears BE…
1.3.6.1.4.1.466.6.1.17.1.11ColumndsucsuDiagFrmEvElapTimeread-onlymandatoryThe time elapsed since the PBX Event Test started. This selection is applicable only for PBX channels.
1.3.6.1.4.1.466.6.1.17.1.12ColumndsucsuDiagFrmEvBpvErrread-onlymandatoryThe number of Bipolar Violations encountered during the Event Test. This selection is applicable only for PBX channels.
1.3.6.1.4.1.466.6.1.17.1.13ColumndsucsuDiagFrmEvOofErrread-onlymandatoryThe number of Out-Of-Frame Errors encountered during the Event Test. This selection is applicable only for PBX channels.
1.3.6.1.4.1.466.6.1.17.1.14ColumndsucsuDiagFrmFrameErrread-onlymandatoryThe number of Frame Errors encountered during the Event Test. This selection is applicable only for PBX channels.
1.3.6.1.4.1.466.6.1.17.1.15ColumndsucsuDiagFrmClearEvRegwrite-onlymandatoryClears all the PBX Event Test registers. This selection is applicable only for PBX channels.
1.3.6.1.4.1.466.6.1.18TabledsucsuDiagAuxTablenot-accessiblemandatoryAuxillary Channel Diagnostics
1.3.6.1.4.1.466.6.1.18.1RowdsucsuDiagAuxEntrynot-accessiblemandatoryAuxilary diagnostic entry
1.3.6.1.4.1.466.6.1.18.1.1ColumndsucsuDiagAuxSlotread-onlymandatoryThe PC port to which the TyView node is attached.
1.3.6.1.4.1.466.6.1.18.1.2ColumndsucsuDiagAuxNoderead-onlymandatoryThe node ID: unique per port ID.
1.3.6.1.4.1.466.6.1.18.1.3ColumndsucsuDiagAuxChAStatusread-onlymandatoryStatus of Supervisory link channel A.
1.3.6.1.4.1.466.6.1.18.1.4ColumndsucsuDiagAuxChBStatusread-onlymandatoryStatus of Supervisory Link Channel B.
1.3.6.1.4.1.466.6.1.18.1.5ColumndsucsuDiagAuxFdlStatusread-onlymandatoryStatus of Facility Data Link (PORT1).
1.3.6.1.4.1.466.6.1.18.1.6ColumndsucsuDiagAuxFdl2Statusread-onlymandatoryStatus of Facility Data Link (PORT2).
1.3.6.1.4.1.466.6.1.18.1.7ColumndsucsuDiagAuxMaintStatusread-onlymandatoryThe Maint. Port Supervisory link status.
1.3.6.1.4.1.466.6.1.18.1.8ColumndsucsuDiagAuxCommStatusread-onlymandatoryThe Communications port Supervisory link status.
1.3.6.1.4.1.466.6.1.19TabledsucsuDiagPortTablenot-accessiblemandatoryPort Specific Display only Diagnostics
1.3.6.1.4.1.466.6.1.19.1RowdsucsuDiagPortEntrynot-accessiblemandatoryPort Specific Display only entry
1.3.6.1.4.1.466.6.1.19.1.1ColumndsucsuDiagPortSlotread-onlymandatoryThe PC port to which the TyView node is attached.
1.3.6.1.4.1.466.6.1.19.1.2ColumndsucsuDiagPortNoderead-onlymandatoryThe node ID: unique per port ID.
1.3.6.1.4.1.466.6.1.19.1.3ColumndsucsuDiagPortIndexread-onlymandatoryThe port index: unique per port.
1.3.6.1.4.1.466.6.1.19.1.4ColumndsucsuDiagPortTyperead-onlymandatoryThe port type (NET/DSX/PBX/V.35/RS-449).
1.3.6.1.4.1.466.6.1.19.1.5ColumndsucsuDiagPortStatusread-onlymandatoryCurrent status condition of a particular port.
1.3.6.1.4.1.466.6.1.20TabledsucsuIntervalTablenot-accessiblemandatoryThe table contains various ESF stats collected over the last 96 15-minute intervals (24 hours total time).
1.3.6.1.4.1.466.6.1.20.1RowdsucsuIntervalEntrynot-accessiblemandatoryEntry in the table of ESF interval stats.
1.3.6.1.4.1.466.6.1.20.1.1ColumndsucsuIntervalSlotread-onlymandatoryThe PC port to which the TyView node is attached.
1.3.6.1.4.1.466.6.1.20.1.2ColumndsucsuIntervalNoderead-onlymandatoryThe node ID: unique per port ID.
1.3.6.1.4.1.466.6.1.20.1.3ColumndsucsuIntervalPortread-onlymandatoryThe port index: unique per port.
1.3.6.1.4.1.466.6.1.20.1.4ColumndsucsuIntervalNumread-onlymandatoryThe sequence number for the selected interval.
1.3.6.1.4.1.466.6.1.20.1.5ColumndsucsuIntervalESsread-onlymandatoryThe number of Errored Seconds (as defined in Bell Publication 62411) encountered in the user registers during the selected interval.
1.3.6.1.4.1.466.6.1.20.1.6ColumndsucsuIntervalSESsread-onlymandatoryThe number of Severely Errored Seconds (as defined in Bell Publication 62411) encountered in the user registers during the selected interval.
1.3.6.1.4.1.466.6.1.20.1.7ColumndsucsuIntervalBPVsread-onlymandatoryThe number of Bipolar Violations (as defined in Bell Publication 62411) encountered in the user registers during the selected interval.
1.3.6.1.4.1.466.6.1.20.1.8ColumndsucsuIntervalFSsread-writemandatoryThe number of Failed Seconds (as defined in Bell Publication 62411) encountered in the user registers during the selected interval.
1.3.6.1.4.1.466.6.1.22TabledsucsuCurrentTablenot-accessiblemandatoryThe table contains various ESF stats collected over the current 15-minute interval.
1.3.6.1.4.1.466.6.1.22.1RowdsucsuCurrentEntrynot-accessiblemandatoryEntry in the table of the current ESF stats.
1.3.6.1.4.1.466.6.1.22.1.1ColumndsucsuCurrentSlotread-onlymandatoryThe PC port to which the TyView node is attached.
1.3.6.1.4.1.466.6.1.22.1.2ColumndsucsuCurrentNoderead-onlymandatoryThe node ID: unique per port ID.
1.3.6.1.4.1.466.6.1.22.1.3ColumndsucsuCurrentPortread-onlymandatoryThe port index: unique per port.
1.3.6.1.4.1.466.6.1.22.1.4ColumndsucsuCurrentESsread-onlymandatoryThe number of Errored Seconds (as defined in Bell Publication 62411) encountered in the user registers during the current 15 minute interval.
1.3.6.1.4.1.466.6.1.22.1.5ColumndsucsuCurrentSESsread-onlymandatoryThe number of Severely Errored Seconds (as defined in Bell Publication 62411) encountered in the user registers during the current 15 minute interval.
1.3.6.1.4.1.466.6.1.22.1.6ColumndsucsuCurrentBPVsread-onlymandatoryThe number of Bipolar Violations (as defined in Bell Publication 62411) encountered in the user registers during the current 15 minute interval.
1.3.6.1.4.1.466.6.1.22.1.7ColumndsucsuCurrentSECsread-onlymandatoryNumber of seconds elapsed in the current 15 minute interval.
1.3.6.1.4.1.466.6.1.22.1.8ColumndsucsuCurrentStatusread-writemandatoryIndication of whether statistics have been halted during current 15 minute interval.
1.3.6.1.4.1.466.6.1.24TabledsucsuTotalTablenot-accessiblemandatoryThe table contains the cummulative sum of various ESF stats collected over the last 24 hour period.
1.3.6.1.4.1.466.6.1.24.1RowdsucsuTotalEntrynot-accessiblemandatoryEntry in the table of the total ESF stats.
1.3.6.1.4.1.466.6.1.24.1.1ColumndsucsuTotalSlotread-onlymandatoryThe PC port to which the TyView node is attached.
1.3.6.1.4.1.466.6.1.24.1.2ColumndsucsuTotalNoderead-onlymandatoryThe node ID: unique per port ID.
1.3.6.1.4.1.466.6.1.24.1.3ColumndsucsuTotalPortread-onlymandatoryThe port index: unique per port.
1.3.6.1.4.1.466.6.1.24.1.4ColumndsucsuTotalESsread-onlymandatoryThe number of Errored Seconds (as defined in Bell Publication 62411) encountered in the user registers in the last 24 hour period (96 intervals).
1.3.6.1.4.1.466.6.1.24.1.5ColumndsucsuTotalSESsread-onlymandatoryThe number of Severely Errored Seconds (as defined in Bell Publication 62411) encountered in the user registers in the last 24 hour period (96 intervals).
1.3.6.1.4.1.466.6.1.24.1.6ColumndsucsuTotalBPVsread-onlymandatoryThe number of Bipolar Violations (as defined in Bell Publication 62411) encountered in the user registers in the last 24 hour period (96 intervals).
1.3.6.1.4.1.466.6.1.24.1.7ColumndsucsuTotalSECsread-onlymandatoryNumber of seconds elapsed in the last 24 hours. This will be the maximum value of 86400 unless the addressed node was brought on-line with the this period.
1.3.6.1.4.1.466.6.1.24.1.8ColumndsucsuTotalStatusread-writemandatoryIndication of whether statistics have been halted in the last 24 hours.
1.3.6.1.4.1.466.6.1.25ScalardsucsuAlarmTyperead-onlymandatoryThe type of alarms that are generated on the node
1.3.6.1.4.1.466.6.1.26ScalardsucsuAlarmSlotread-onlymandatoryThe PC port to which the TyView node is attached.
1.3.6.1.4.1.466.6.1.27ScalardsucsuAlarmNoderead-onlymandatoryThe node ID: unique per port ID.
1.3.6.1.4.1.466.6.1.28ScalardsucsuAlarmNameread-onlymandatoryThe name of the node which triggered the alarm.
1.3.6.1.4.1.466.6.2Nodetyview
1.3.6.1.4.1.466.6.2.1NodetyviewSysTable
1.3.6.1.4.1.466.6.2.1.1ScalartyviewSysRevSwread-onlymandatoryThe TyView software revision.
1.3.6.1.4.1.466.6.2.1.2ScalartyviewSysNameread-writemandatoryThe name given to TyView system.
1.3.6.1.4.1.466.6.2.1.3ScalartyviewSysIdread-onlymandatoryThe TyView system ID.
1.3.6.1.4.1.466.6.2.1.4ScalartyviewSysTimeOutFactorread-writemandatoryThe TyView timeout factor.
1.3.6.1.4.1.466.6.2.1.5ScalartyviewSysObjectIdread-writemandatoryThe Tyview Domain Object Identifier.
1.3.6.1.4.1.466.6.2.1.6ScalartyviewSysSlotNumberread-onlymandatoryThe Physical Slot Number the NETEXEC is installed in.
1.3.6.1.4.1.466.6.2.1.7ScalartyviewSysClearDatabasewrite-onlymandatoryClear the node database.
1.3.6.1.4.1.466.6.2.1.8ScalartyviewSysGetCommNameread-writemandatoryThe GET community name.
1.3.6.1.4.1.466.6.2.1.9ScalartyviewSysSetCommNameread-writemandatoryThe SET community name.
1.3.6.1.4.1.466.6.2.1.10ScalartyviewSysTrapCommNameread-writemandatoryThe TRAP community name.
1.3.6.1.4.1.466.6.2.1.11ScalartyviewSysN1TrapDestread-writemandatoryThe first Trap IP Destination.
1.3.6.1.4.1.466.6.2.1.12ScalartyviewSysN2TrapDestread-writemandatoryThe second Trap IP Destination.
1.3.6.1.4.1.466.6.2.1.13ScalartyviewSysDateread-writemandatoryThe NETEXEC date (mm/dd/yy).
1.3.6.1.4.1.466.6.2.1.14ScalartyviewSysTimeread-writemandatoryThe NETEXEC time (hh:mm).
1.3.6.1.4.1.466.6.2.1.15ScalartyviewSysMjrMnrLEDread-onlymandatoryThe Major/Minor LED status.
1.3.6.1.4.1.466.6.2.1.16ScalartyviewSysFanPSLEDread-onlymandatoryThe Fan / Power Supply LED status.
1.3.6.1.4.1.466.6.2.1.17ScalartyviewSysCtlrLEDread-onlymandatoryThe Controller LED status.
1.3.6.1.4.1.466.6.2.1.18ScalartyviewSysSlipLEDread-onlymandatoryThe SLIP LED status.
1.3.6.1.4.1.466.6.2.1.19ScalartyviewSysCtlChLEDread-onlymandatoryThe Control Channel LED status.
1.3.6.1.4.1.466.6.2.1.20ScalartyviewSysTDMLEDread-onlymandatoryThe TDM LED status.
1.3.6.1.4.1.466.6.2.1.21ScalartyviewSysMaintUseageread-writemandatoryThe Maintenance Port useage specification.
1.3.6.1.4.1.466.6.2.1.22ScalartyviewSysMaintDataBitsread-writemandatoryThe Maintenance Port databits specification.
1.3.6.1.4.1.466.6.2.1.23ScalartyviewSysMaintRateread-writemandatoryThe Maintenance Port rate specification.
1.3.6.1.4.1.466.6.2.1.24ScalartyviewSysMaintStopBitsread-writemandatoryThe Maintenance Port stopbits specification.
1.3.6.1.4.1.466.6.2.1.25ScalartyviewSysMaintParityread-writemandatoryThe Maintenance Port parity specification.
1.3.6.1.4.1.466.6.2.1.26ScalartyviewSysMaintMturead-writemandatoryThe Maintenance Port maximum trans unit size.
1.3.6.1.4.1.466.6.2.1.27ScalartyviewSysMaintCompressionread-writemandatoryThe Maintenance Port compression specification.
1.3.6.1.4.1.466.6.2.1.28ScalartyviewSysMaintSubnetMaskread-writemandatoryThe Maintenance Port subnet mask.
1.3.6.1.4.1.466.6.2.1.29ScalartyviewSysMaintLocalIPread-writemandatoryThe Maintenance Port local IP address.
1.3.6.1.4.1.466.6.2.1.30ScalartyviewSysMaintPeerIPread-writemandatoryThe Maintenance Port peer IP address.
1.3.6.1.4.1.466.6.2.1.31ScalartyviewSysComUseageread-writemandatoryThe Com Port useage specification.
1.3.6.1.4.1.466.6.2.1.32ScalartyviewSysComDataBitsread-writemandatoryThe Com Port databits specification.
1.3.6.1.4.1.466.6.2.1.33ScalartyviewSysComRateread-writemandatoryThe Com Port rate specification.
1.3.6.1.4.1.466.6.2.1.34ScalartyviewSysComStopBitsread-writemandatoryThe Com Port stopbits specification.
1.3.6.1.4.1.466.6.2.1.35ScalartyviewSysComParityread-writemandatoryThe Com Port parity specification.
1.3.6.1.4.1.466.6.2.1.36ScalartyviewSysComMturead-writemandatoryThe Com Port maximum trans unit size.
1.3.6.1.4.1.466.6.2.1.37ScalartyviewSysComCompressionread-writemandatoryThe Com Port compression specification.
1.3.6.1.4.1.466.6.2.1.38ScalartyviewSysComSubnetMaskread-writemandatoryThe Com Port subnet mask.
1.3.6.1.4.1.466.6.2.1.39ScalartyviewSysComLocalIPread-writemandatoryThe Com Port local IP address.
1.3.6.1.4.1.466.6.2.1.40ScalartyviewSysComPeerIPread-writemandatoryThe Com Port peer IP address.
1.3.6.1.4.1.466.6.2.1.41ScalartyviewSysTelnetEnaread-writemandatoryThe Telnet log-in enable.
1.3.6.1.4.1.466.6.2.1.42ScalartyviewSysTelnetTOread-writemandatoryThe Telnet auto-logout timeout (minutes).
1.3.6.1.4.1.466.6.2.1.43ScalartyviewSysClrMjrMinwrite-onlymandatoryClear major/minor alarm window / LED.
1.3.6.1.4.1.466.6.2.2TabletyviewDatabaseTablenot-accessiblemandatoryA list of tyview database entries.
1.3.6.1.4.1.466.6.2.2.1RowtyviewDatabaseEntrynot-accessiblemandatorySystem Object for TyView Database
1.3.6.1.4.1.466.6.2.2.1.1ColumntyviewDatabaseSlotread-onlymandatoryThe PC port to which the node is attached.
1.3.6.1.4.1.466.6.2.2.1.2ColumntyviewDatabaseNoderead-onlymandatoryThe node ID: unique per port ID.
1.3.6.1.4.1.466.6.2.2.1.3ColumntyviewDatabaseNameread-writemandatoryThe unique name of the node.
1.3.6.1.4.1.466.6.2.2.1.4ColumntyviewDatabaseStatusread-onlymandatoryThe last comm status.
1.3.6.1.4.1.466.6.2.3NodetyviewBroadcastTable
1.3.6.1.4.1.466.6.2.3.1ScalartyviewBroadcastSetTimewrite-onlymandatoryBroadcast the time to all nodes.
1.3.6.1.4.1.466.6.2.3.2ScalartyviewBroadcastForwardAlarmswrite-onlymandatoryBroadcast alarm forwarding.
1.3.6.1.4.1.466.6.2.3.3ScalartyviewBroadcastClearLoopbackswrite-onlymandatoryBroadcast Clearing of loopbacks.
1.3.6.1.4.1.466.6.2.4TabletyviewTPTablenot-accessiblemandatoryA list of Threshold Processing records.
1.3.6.1.4.1.466.6.2.4.1RowtyviewTPEntrynot-accessiblemandatorySystem Object for Threshold Processing
1.3.6.1.4.1.466.6.2.4.1.1ColumntyviewTPRecordread-onlymandatoryThe Threshold Processing record referenced.
1.3.6.1.4.1.466.6.2.4.1.2ColumntyviewTPMonNodeModeread-writemandatoryThe mode used for monitoring nodes.
1.3.6.1.4.1.466.6.2.4.1.3ColumntyviewTPNoderead-writemandatoryThe node name for node-specific monitoring.
1.3.6.1.4.1.466.6.2.4.1.4ColumntyviewTPAlarmTyperead-writemandatoryThe alarm type used to trigger.
1.3.6.1.4.1.466.6.2.4.1.5ColumntyviewTPTriggerEventread-writemandatoryThe event type used to trigger.
1.3.6.1.4.1.466.6.2.4.1.6ColumntyviewTPInstanceread-writemandatoryThe alarm instance used to trigger.
1.3.6.1.4.1.466.6.2.4.1.7ColumntyviewTPIntervalread-writemandatoryThe alarm interval used to trigger.
1.3.6.1.4.1.466.6.2.4.1.8ColumntyviewTPEventActionread-writemandatoryThe phone number dialed when triggered.
1.3.6.1.4.1.466.6.2.4.1.9ColumntyviewTPDryContactread-writemandatoryThe type of Dry Contact when triggered.
1.3.6.1.4.1.466.6.2.4.1.10ColumntyviewTPClearDryContactwrite-onlymandatoryClear major/minor Dry Contact.