MIB Viewer

NETWORK-TECHNOLOGIES-GLOBAL-REG

90 objects
No module-level DESCRIPTION found.
Imported Objects
SNMPv2-SMIenterprises MODULE-IDENTITY OBJECT-IDENTITY OBJECT-TYPE
SNMPv2-TCDISPLAY-HINT DisplayString TEXTUAL-CONVENTION
OIDNameAccessStatusDescription
1.3.6.1.4.1.3699Nodenti
1.3.6.1.4.1.3699.1Nodeproducts
1.3.6.1.4.1.3699.1.1Nodehardware
1.3.6.1.4.1.3699.1.1.3NodeENVIROMUX-MINI
1.3.6.1.4.1.3699.1.1.3.1Nodemonitoring
1.3.6.1.4.1.3699.1.1.3.1.1NodetemperatureSensor1
1.3.6.1.4.1.3699.1.1.3.1.1.1ScalartemperatureSensor1CurrentValueread-onlymandatoryCurrent value of the temperature sensor connected to port 1 in tenths of degrees . This port is the right RJ-45 sensor port. The value is expressed in the unit…
1.3.6.1.4.1.3699.1.1.3.1.1.2ScalartemperatureSensor1Alertread-onlymandatoryCurrent alert status of the temperature sensor connected to port 1. This port is the right RJ-45 sensor port. A value of 0 indicates that the sensor has not cr…
1.3.6.1.4.1.3699.1.1.3.1.2NodetemperatureSensor2
1.3.6.1.4.1.3699.1.1.3.1.2.1ScalartemperatureSensor2CurrentValueread-onlymandatoryCurrent value of the temperature sensor connected to port 2 in tenths of degrees . This port is the left RJ-45 sensor port. The value is expressed in the units…
1.3.6.1.4.1.3699.1.1.3.1.2.2ScalartemperatureSensor2Alertread-onlymandatoryCurrent alert status of the temperature sensor connected to port 2. This port is the left RJ-45 sensor port. A value of 0 indicates that the sensor has not cro…
1.3.6.1.4.1.3699.1.1.3.1.3NodehumiditySensor1
1.3.6.1.4.1.3699.1.1.3.1.3.1ScalarhumiditySensor1CurrentValueread-onlymandatoryCurrent integer value in tenths of percents of the humidity sensor connected to port 1. This port is the right RJ-45 sensor port. The value corresponds directl…
1.3.6.1.4.1.3699.1.1.3.1.3.2ScalarhumiditySensor1Alertread-onlymandatoryCurrent alert status of the humidity sensor connected to port 1. This port is the right RJ-45 sensor port. A value of 0 indicates that the sensor has not cross…
1.3.6.1.4.1.3699.1.1.3.1.4NodehumiditySensor2
1.3.6.1.4.1.3699.1.1.3.1.4.1ScalarhumiditySensor2CurrentValueread-onlymandatoryCurrent integer value in tenths of percents of the humidity sensor connected to port 2. This port is the left RJ-45 sensor port. The value corresponds directly…
1.3.6.1.4.1.3699.1.1.3.1.4.2ScalarhumiditySensor2Alertread-onlymandatoryCurrent alert status of the humidity sensor connected to port 2. This port is the left RJ-45 sensor port. A value of 0 indicates that the sensor has not crosse…
1.3.6.1.4.1.3699.1.1.3.1.5NodedryContact1
1.3.6.1.4.1.3699.1.1.3.1.5.1ScalardryContact1Statusread-onlymandatoryCurrent integer value of the dry contact sensor connected to port 1. A value of 0 represents OPEN, and a value of 1 represents CLOSED. The value corresponds di…
1.3.6.1.4.1.3699.1.1.3.1.5.2ScalardryContact1Alertread-onlymandatoryCurrent alert status of the dry contact sensor connected to port 1. A value of 0 indicates that the sensor has not been set to its alert condition, while a val…
1.3.6.1.4.1.3699.1.1.3.1.6NodedryContact2
1.3.6.1.4.1.3699.1.1.3.1.6.1ScalardryContact2Statusread-onlymandatoryCurrent integer value of the dry contact sensor connected to port 2. A value of 0 represents OPEN, and a value of 1 represents CLOSED. The value corresponds di…
1.3.6.1.4.1.3699.1.1.3.1.6.2ScalardryContact2Alertread-onlymandatoryCurrent alert status of the dry contact sensor connected to port 2. value of 0 indicates that the sensor has not been set to its alert condition, while a value…
1.3.6.1.4.1.3699.1.1.3.1.7NodedryContact3
1.3.6.1.4.1.3699.1.1.3.1.7.1ScalardryContact3Statusread-onlymandatoryCurrent integer value of the dry contact sensor connected to port 3. A value of 0 represents OPEN, and a value of 1 represents CLOSED. The value corresponds di…
1.3.6.1.4.1.3699.1.1.3.1.7.2ScalardryContact3Alertread-onlymandatoryCurrent alert status of the dry contact sensor connected to port 3. A value of 0 indicates that the sensor has not been set to its alert condition, while a val…
1.3.6.1.4.1.3699.1.1.3.1.8NodedryContact4
1.3.6.1.4.1.3699.1.1.3.1.8.1ScalardryContact4Statusread-onlymandatoryCurrent integer value of the dry contact sensor connected to port 4. A value of 0 represents OPEN, and a value of 1 represents CLOSED. The value corresponds di…
1.3.6.1.4.1.3699.1.1.3.1.8.2ScalardryContact4Alertread-onlymandatoryCurrent alert status of the dry contact sensor connected to port 4. A value of 0 indicates that the sensor has not been set to its alert condition, while a val…
1.3.6.1.4.1.3699.1.1.3.1.9NodewaterSensor
1.3.6.1.4.1.3699.1.1.3.1.9.1ScalarwaterStatusread-onlymandatoryCurrent integer value of the water sensor. A value of 0 represents OPEN, and a value of 1 represents CLOSED. The value corresponds directly with the value disp…
1.3.6.1.4.1.3699.1.1.3.1.9.2ScalarwaterAlertread-onlymandatoryCurrent alert status of the water sensor. A value of 0 indicates that the sensor has not been set to its alert condition, while a value of 1 indicates that it …
1.3.6.1.4.1.3699.1.1.3.2Nodeadministration
1.3.6.1.4.1.3699.1.1.3.2.1NodehostSystem
1.3.6.1.4.1.3699.1.1.3.2.1.1ScalarsysNameread-onlymandatorySystem node name. This value corresponds directly with the Node Name field on the General configuration page under the ADMINISTRATION menu.
1.3.6.1.4.1.3699.1.1.3.2.1.2ScalarsysLocationread-onlymandatorySystem node location. his value corresponds directly with the Node Location field on the General configuration page under the ADMINISTRATION menu.
1.3.6.1.4.1.3699.1.1.3.2.1.3ScalarsysIPread-onlymandatorySystem IP address. This value corresponds directly with the IP address assigned to the ENVIROMUX-MINI on the Network configuration page under the ADMINISTRATIO…
1.3.6.1.4.1.3699.1.1.3.2.1.4ScalarsysMaskread-onlymandatorySystem Subnet Mask. This value corresponds directly with the Subnet Mask assigned to the ENVIROMUX-MINI on the Network configuration page under the ADMINISTRAT…
1.3.6.1.4.1.3699.1.1.3.2.1.5ScalarsysGatewayread-onlymandatorySystem Default Gateway. This value corresponds directly with the Default Gateway assigned to the ENVIROMUX-MINI on the Network configuration page under the ADM…
1.3.6.1.4.1.3699.1.1.3.2.1.6ScalarsysDNSread-onlymandatorySystem DNS server. This value corresponds directly with the DNS server assigned to the ENVIROMUX-MINI on the Network configuration page under the ADMINISTRATIO…
1.3.6.1.4.1.3699.1.1.3.2.2NodetemperatureSensor1Adm
1.3.6.1.4.1.3699.1.1.3.2.2.1ScalartemperatureSensor1Nameread-writemandatoryCurrent name assigned to the temperature sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the name en…
1.3.6.1.4.1.3699.1.1.3.2.2.2ScalartemperatureSensor1Unitread-writemandatoryTemperature units for the value of the temperature sensor connected to port 1. This port is the right RJ-45 sensor port. The unit may either be Fahrenheit or C…
1.3.6.1.4.1.3699.1.1.3.2.2.3ScalartemperatureSensor1LowThresholdread-writemandatoryLow threshold assigned to the temperature sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the low th…
1.3.6.1.4.1.3699.1.1.3.2.2.4ScalartemperatureSensor1HighThresholdread-writemandatoryHigh threshold assigned to the temperature sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the high …
1.3.6.1.4.1.3699.1.1.3.2.3NodetemperatureSensor2Adm
1.3.6.1.4.1.3699.1.1.3.2.3.1ScalartemperatureSensor2Nameread-writemandatoryCurrent name assigned to the temperature sensor connected to port 2. This port is the left RJ-45 sensor port. This value corresponds directly with the name ent…
1.3.6.1.4.1.3699.1.1.3.2.3.2ScalartemperatureSensor2Unitread-writemandatoryTemperature units for the value of the temperature sensor connected to port 2. This port is the left RJ-45 sensor port. The unit may either be Fahrenheit or Ce…
1.3.6.1.4.1.3699.1.1.3.2.3.3ScalartemperatureSensor2LowThresholdread-writemandatoryLow threshold assigned to the temperature sensor connected to port 2. This port is the left RJ-45 sensor port. This value corresponds directly with the low thr…
1.3.6.1.4.1.3699.1.1.3.2.3.4ScalartemperatureSensor2HighThresholdread-writemandatoryHigh threshold assigned to the temperature sensor connected to port 2. This port is the left RJ-45 sensor port. This value corresponds directly with the high t…
1.3.6.1.4.1.3699.1.1.3.2.4NodehumiditySensor1Adm
1.3.6.1.4.1.3699.1.1.3.2.4.1ScalarhumiditySensor1Nameread-writemandatoryCurrent name assigned to the humidity sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the name enter…
1.3.6.1.4.1.3699.1.1.3.2.4.2ScalarhumiditySensor1LowThresholdread-writemandatoryLow threshold assigned to the humidity sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the low thres…
1.3.6.1.4.1.3699.1.1.3.2.4.3ScalarhumiditySensor1HighThresholdread-writemandatoryHigh threshold assigned to the humidity sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the high thr…
1.3.6.1.4.1.3699.1.1.3.2.5NodehumiditySensor2Adm
1.3.6.1.4.1.3699.1.1.3.2.5.1ScalarhumiditySensor2Nameread-writemandatoryCurrent name assigned to the humidity sensor connected to port 2. This port is the left RJ-45 sensor port. This value corresponds directly with the name entere…
1.3.6.1.4.1.3699.1.1.3.2.5.2ScalarhumiditySensor2LowThresholdread-writemandatoryLow threshold assigned to the humidity sensor connected to port 2. This port is the left RJ-45 sensor port. This value corresponds directly with the low thresh…
1.3.6.1.4.1.3699.1.1.3.2.5.3ScalarhumiditySensor2HighThresholdread-writemandatoryHigh threshold assigned to the humidity sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the high thr…
1.3.6.1.4.1.3699.1.1.3.2.6NodedryContact1Adm
1.3.6.1.4.1.3699.1.1.3.2.6.1ScalardryContact1Nameread-writemandatoryCurrent name assigned to the dry contact sensor connected to port 1. This value corresponds directly with the name entered in the configuration page for this s…
1.3.6.1.4.1.3699.1.1.3.2.6.2ScalardryContact1AlertStatusread-writemandatoryStatus which generates an alert condition for the dry contact sensor connected to port 1. A value of 0 represents OPEN, and a value of 1 represents CLOSED. Thi…
1.3.6.1.4.1.3699.1.1.3.2.7NodedryContact2Adm
1.3.6.1.4.1.3699.1.1.3.2.7.1ScalardryContact2Nameread-writemandatoryCurrent name assigned to the dry contact sensor connected to port 2. This value corresponds directly with the name entered in the configuration page for this s…
1.3.6.1.4.1.3699.1.1.3.2.7.2ScalardryContact2AlertStatusread-writemandatoryStatus which generates an alert condition for the dry contact sensor connected to port 2. A value of 0 represents OPEN, and a value of 1 represents CLOSED. Thi…
1.3.6.1.4.1.3699.1.1.3.2.8NodedryContact3Adm
1.3.6.1.4.1.3699.1.1.3.2.8.1ScalardryContact3Nameread-writemandatoryCurrent name assigned to the dry contact sensor connected to port 3. This value corresponds directly with the name entered in the configuration page for this s…
1.3.6.1.4.1.3699.1.1.3.2.8.2ScalardryContact3AlertStatusread-writemandatoryStatus which generates an alert condition for the dry contact sensor connected to port 3. A value of 0 represents OPEN, and a value of 1 represents CLOSED. Thi…
1.3.6.1.4.1.3699.1.1.3.2.9NodedryContact4Adm
1.3.6.1.4.1.3699.1.1.3.2.9.1ScalardryContact4Nameread-writemandatoryCurrent name assigned to the dry contact sensor connected to port 4. This value corresponds directly with the name entered in the configuration page for this s…
1.3.6.1.4.1.3699.1.1.3.2.9.2ScalardryContact4AlertStatusread-writemandatoryStatus which generates an alert condition for the dry contact sensor connected to port 4. A value of 0 represents OPEN, and a value of 1 represents CLOSED. Thi…
1.3.6.1.4.1.3699.1.1.3.2.10NodewaterSensorAdm
1.3.6.1.4.1.3699.1.1.3.2.10.1ScalarwaterNameread-writemandatoryCurrent name assigned to the water sensor. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only…
1.3.6.1.4.1.3699.1.1.3.2.10.2ScalarwaterAlertStatusread-writemandatoryStatus which generates an alert condition for the water sensor. A value of 0 represents OPEN, and a value of 1 represents CLOSED. This value corresponds direct…
1.3.6.1.4.1.3699.1.1.3.3Scalarversionread-onlymandatoryCode version
1.3.6.1.4.1.3699.1.1.3.100NodeenvTraps
1.3.6.1.4.1.3699.1.1.3.100.1NotificationtemperatureSensor1TrapcurrentTrap for alert from temperature sensor connected to port 1. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is …
1.3.6.1.4.1.3699.1.1.3.100.2NotificationtemperatureSensor2TrapcurrentTrap for alert from temperature sensor connected to port 2. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is …
1.3.6.1.4.1.3699.1.1.3.100.3NotificationhumiditySensor1TrapcurrentTrap for alert from humidity sensor connected to port 1. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is ena…
1.3.6.1.4.1.3699.1.1.3.100.4NotificationhumiditySensor2TrapcurrentTrap for alert from humidity sensor connected to port 2. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is ena…
1.3.6.1.4.1.3699.1.1.3.100.5NotificationdryContactSensor1TrapcurrentTrap for alert from dry contact sensor connected to port 1. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is …
1.3.6.1.4.1.3699.1.1.3.100.6NotificationdryContactSensor2TrapcurrentTrap for alert from dry contact sensor connected to port 2. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is …
1.3.6.1.4.1.3699.1.1.3.100.7NotificationdryContactSensor3TrapcurrentTrap for alert from dry contact sensor connected to port 3. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is …
1.3.6.1.4.1.3699.1.1.3.100.8NotificationdryContactSensor4TrapcurrentTrap for alert from dry contact sensor connected to port 4. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is …
1.3.6.1.4.1.3699.1.1.3.100.9NotificationwaterSensor1TrapcurrentTrap for alert from water sensor. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network con…
1.3.6.1.4.1.3699.1.1.3.100.100NotificationlogTrapcurrentTrap generated when a log entry is created. Received if log entries are configured to be sent as SNMP traps using the Log Methods page, and SNMP is enabled on …
1.3.6.1.4.1.3699.1.1.3.100.101NotificationoverflowTrapcurrentTrap generated when has reached 90% capacity. Received if log overflow alerts are enabled and are configured to be sent as SNMP traps using the Log Overflow pa…
1.3.6.1.4.1.3699.1.1.200NodeotherProduct
1.3.6.1.4.1.3699.1.2Nodesoftware
1.3.6.1.4.1.3699.2Nodeexperimental
Type Definitions
NameSyntaxStatusDescription
DecimalPointValueInteger32mandatoryDisplay integer values using a decimal point before last digit