NEWBRIDGE-MIB
234 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.123.2.1 | NodennciSystem | |||
| 1.3.6.1.4.1.123.2.1.1 | TablennciSystemTable | not-accessible | mandatory | This table contains interesting general information about the managed element in its entirety |
| 1.3.6.1.4.1.123.2.1.1.1 | RownnciSystemTableEntry | not-accessible | mandatory | A list of general information about the managed element |
| 1.3.6.1.4.1.123.2.1.1.1.2 | ColumnnnciSystemDate | read-write | mandatory | The current date as known by the node.The date is formatted as a sequence of nine ASCII characters in the form DD-MMM-YY, where DD is the day of the month (01.… |
| 1.3.6.1.4.1.123.2.1.1.1.4 | ColumnnnciSystemProductName | read-only | mandatory | The marketing name for the product, e.g. 8230 MainStreet for something if sysObjectId.0 = nnci8230 |
| 1.3.6.1.4.1.123.2.1.1.1.5 | ColumnnnciSystemGeneric | read-only | mandatory | This object identifies the revision of the firmware in the standard Newbridge fashion. The identifier is a string of 10 ASCII characters of the form M11D-HL-PP… |
| 1.3.6.1.4.1.123.2.1.1.1.30 | ColumnnnciSystemNVMAllocation | read-only | mandatory | This object provides status information about the non-volatile memory present on the main card of the system. The information returned includes the size of a s… |
| 1.3.6.1.4.1.123.2.1.1.1.31 | ColumnnnciSystemNVMRepairInfo | read-only | mandatory | This object returns the details of the latest repair performed on the non-volatile memory present on the main card. |
| 1.3.6.1.4.1.123.2.1.1.1.38 | ColumnnnciSystemTime | read-write | mandatory | The current time of day including seconds. The time is represented as a sequence of 9 ASCII characters in the form HH:MM:SS, where HH is the hour of the day (0… |
| 1.3.6.1.4.1.123.2.2 | NodennciSp | |||
| 1.3.6.1.4.1.123.2.2.1 | TablennciSerialPortTable | not-accessible | mandatory | This table contains the configuration information for an asynchronous management port for a standalone node. |
| 1.3.6.1.4.1.123.2.2.1.1 | RownnciSerialPortTableEntry | not-accessible | mandatory | A list of configuration information for a management port on a standalone node |
| 1.3.6.1.4.1.123.2.2.1.1.1 | ColumnnnciSpBaudRate | read-write | mandatory | The baud rate of the asynchronous management port. |
| 1.3.6.1.4.1.123.2.2.1.1.2 | ColumnnnciSpWordLength | read-write | mandatory | The word length used on the asynchronous management port. |
| 1.3.6.1.4.1.123.2.2.1.1.3 | ColumnnnciSpStopBits | read-write | mandatory | The number of stop bits used by the asynchronous management port. |
| 1.3.6.1.4.1.123.2.2.1.1.4 | ColumnnnciSpParity | read-write | mandatory | The parity used on the asynchronous management port. |
| 1.3.6.1.4.1.123.2.3 | NodennciDiag | |||
| 1.3.6.1.4.1.123.2.3.1 | TablennciDiagTable | not-accessible | mandatory | This table contains all of the configuration and status information related to diagnostics on a node. |
| 1.3.6.1.4.1.123.2.3.1.1 | RownnciDiagTableEntry | not-accessible | mandatory | A list of all of the configuration and status information related to node diagnostics. |
| 1.3.6.1.4.1.123.2.3.1.1.1 | ColumnnnciDiagEnable | read-write | mandatory | This object controls whether or not background diagnostics are run. If the object is set to 2 (enabled), then background diagnostics are run periodically. If t… |
| 1.3.6.1.4.1.123.2.3.1.1.5 | ColumnnnciDiagResults | read-only | mandatory | This object indicates the results of power on and background diagnostics. Any bit that is asserted corresponds to a failure of a component of the card. |
| 1.3.6.1.4.1.123.2.4 | NodennciAlarm | |||
| 1.3.6.1.4.1.123.2.4.1 | TablennciAlarmTable | not-accessible | mandatory | This table contains all the configuration and status information about the alarm mechanism along with the alarms themselves. |
| 1.3.6.1.4.1.123.2.4.1.1 | RownnciAlarmTableEntry | not-accessible | mandatory | A list of all of the configuration and status information for a node, along with the alarm queues themselves. |
| 1.3.6.1.4.1.123.2.4.1.1.1 | ColumnnnciAlarmCount | read-only | mandatory | The number of alarms in the specified queue. |
| 1.3.6.1.4.1.123.2.4.1.1.2 | ColumnnnciAlarmQueueEntry | read-only | mandatory | When read, this object returns the particulars of the entry in the specified queue. |
| 1.3.6.1.4.1.123.2.4.1.1.3 | ColumnnnciAlarmQueueEntryStatus | write-only | mandatory | The status of an alarm. |
| 1.3.6.1.4.1.123.2.4.1.1.4 | ColumnnnciAlarmSeqNum | read-only | mandatory | The next sequence number that will be used by the node. The sequence numbers are a unique, within a single node, identifier for an alarm. |
| 1.3.6.1.4.1.123.2.4.1.1.6 | ColumnnnciAlarmCodePriority | read-write | mandatory | This value of this object controls into which queue an alarm is placed. |
| 1.3.6.1.4.1.123.2.4.1.1.8 | ColumnnnciAlarmDeleteQueueEntry | write-only | mandatory | A set to this object is deletes the first N alarms from the specified alarm queue. |
| 1.3.6.1.4.1.123.2.4.1.1.9 | ColumnnnciAlarmQueueType | read-write | mandatory | This paramater is used to control the behaviour of the alarm queue in the overlfow case, i.e. when the alarm facility attempts to place the 65th alarm into the… |
| 1.3.6.1.4.1.123.2.7 | NodennciNetSynch | |||
| 1.3.6.1.4.1.123.2.7.1 | TablennciNetSynchTable | not-accessible | mandatory | This table contains all of the configuration and status information for the network synchronization mechanism for a standalone node. |
| 1.3.6.1.4.1.123.2.7.1.1 | RownnciNetSynchTableEntry | not-accessible | mandatory | A list of all of the configuration and status information related to network synchronization. |
| 1.3.6.1.4.1.123.2.7.1.1.1 | ColumnnnciNetSynchSourceStatus | read-write | mandatory | This object returns the current status of the specified source of synchronization. A set to this object changes the enabled/disabled status of the source. If t… |
| 1.3.6.1.4.1.123.2.7.1.1.2 | ColumnnnciNetSynchTimingSource | read-write | mandatory | The device which provides timing when the specified source of synchronization is selected. The sync source must be disabled before changing this object. |
| 1.3.6.1.4.1.123.2.7.1.1.3 | ColumnnnciNetSynchReacquisitionMode | read-write | mandatory | How the source of synchronization will be treated in the event a failure is detected. If Manual is selected, the source will remain unused until it is re-selec… |
| 1.3.6.1.4.1.123.2.7.1.1.4 | ColumnnnciNetSynchCurrentSource | read-write | mandatory | The current source of synchronization for the node. A set to this object toggles the ready/current status of the source. If the source is ready, it will become… |
| 1.3.6.1.4.1.123.2.7.1.1.6 | ColumnnnciNetSynchRecoveryInterval | read-write | mandatory | This object is used to set the interval between recovery attempts for a source of synchronization that is using Timed recovery in seconds. |
| 1.3.6.1.4.1.123.2.7.1.1.9 | ColumnnnciNetSynchQuality | read-write | mandatory | This object is used to set the maximum permissible number of failures that can be experienced by a source in an hour. If this limit is exceeded, an alarm is ra… |
| 1.3.6.1.4.1.123.2.7.1.1.11 | ColumnnnciNetSynchSourceClass | read-write | mandatory | This object is used to set the class of a source. The source with the best class will provide system sync when several sources are Ready. Note that the freerun… |
| 1.3.6.1.4.1.123.2.7.1.1.12 | ColumnnnciNetSynchNodeClass | read-write | mandatory | This object is used to set the class of the node. The node will freerun if the value of this object is lower than the nnciNetSynchSourceClass of the other sour… |
| 1.3.6.1.4.1.123.2.10 | NodennciSlot | |||
| 1.3.6.1.4.1.123.2.10.1 | TablennciSlotTable | not-accessible | mandatory | This table contains all of the common, slot configuration and status information for a standalone node |
| 1.3.6.1.4.1.123.2.10.1.1 | RownnciSlotTableEntry | not-accessible | mandatory | A list of all of the common, per-slot configuration and status information for a standalone node. |
| 1.3.6.1.4.1.123.2.10.1.1.1 | ColumnnnciSlotName | read-write | mandatory | An arbitrary name for a slot. |
| 1.3.6.1.4.1.123.2.10.1.1.2 | ColumnnnciSlotProgType | read-write | mandatory | This object is used to specify what kind of module should be present in the specified position . If the value in this object does not match the value in the nn… |
| 1.3.6.1.4.1.123.2.10.1.1.3 | ColumnnnciSlotPresType | read-only | mandatory | This object is used to specify what kind of module is present in the specified position . If the value of this object does not match the value of the nnciSlotP… |
| 1.3.6.1.4.1.123.2.10.1.1.4 | ColumnnnciSlotStatus | read-write | mandatory | This object contains the current status of the specified position . The status reflects whether a module is present, and if so, is it of the expected type. |
| 1.3.6.1.4.1.123.2.10.1.1.5 | ColumnnnciSlotModuleID | read-only | mandatory | The hardware identification number assigned to the module that is present in the specified position. If there is no module installed in the position, the value… |
| 1.3.6.1.4.1.123.2.10.1.1.6 | ColumnnnciSlotSubModuleProgType | read-write | mandatory | What kind of 'sub-module' should be present in the specified slot. If the value in this object does not match the value in the nnciSlotModulePresType object, t… |
| 1.3.6.1.4.1.123.2.10.1.1.7 | ColumnnnciSlotSubModulePresType | read-only | mandatory | What kind of 'sub-module' is present in the specified position. If the value of this object does not match the value of the nnciSlotModuleProgType object, the … |
| 1.3.6.1.4.1.123.2.10.1.1.8 | ColumnnnciSlotFirmwareID | read-only | mandatory | The revision level of the firmware, if any, that is present on a module. If no firmware is present, the value will be zero. |
| 1.3.6.1.4.1.123.2.10.1.1.9 | ColumnnnciSlotBusyOut | read-write | mandatory | This object is used to take circuits on a specified slot out of service. If the value of this object is hold-out-of-service, then the circuits on the slot will… |
| 1.3.6.1.4.1.123.2.10.1.1.10 | ColumnnnciSlotSubModuleID | read-only | mandatory | The hardware identification number assigned to the sub-module that is present in the specified position. If there is no sub-module installed in the position, o… |
| 1.3.6.1.4.1.123.2.10.1.1.14 | ColumnnnciSlotVariantID | read-only | mandatory | The variant identification number for the module which is installed in the specified slot. If there is no module installed, the value returned will be zero. |
| 1.3.6.1.4.1.123.2.10.1.1.15 | ColumnnnciSlotResetCard | read-write | mandatory | This object is used to cause the node to re-initialize the specified module. Any set to this object will cause the specified module to be re-initialized. If a … |
| 1.3.6.1.4.1.123.2.10.1.1.19 | ColumnnnciSlotHardwareRevision | read-only | mandatory | The engineering revision level of the module that occupies the specified position. The high nibble of the returned value is the major revision level and the lo… |
| 1.3.6.1.4.1.123.2.11 | NodennciDev | |||
| 1.3.6.1.4.1.123.2.11.1 | TablennciDevTable | not-accessible | mandatory | This table contains all of the common, per-device configuration and status information for a circuit. Device-type specific information is found in other tables… |
| 1.3.6.1.4.1.123.2.11.1.1 | RownnciDevTableEntry | not-accessible | mandatory | A list of all of the common, per-device configuration and status information. |
| 1.3.6.1.4.1.123.2.11.1.1.2 | ColumnnnciDevName | read-write | mandatory | A user-defined name for the specified circuit. |
| 1.3.6.1.4.1.123.2.11.1.1.4 | ColumnnnciDevLoopback | read-write | mandatory | This object is used to apply and remove loopbacks on the specified circuit. Note that it may not be possible to apply loopbacks to some circuit types. |
| 1.3.6.1.4.1.123.2.11.1.1.5 | ColumnnnciDevMateDevice | read-only | mandatory | The device number of the device, if any, that is cross-connected to the device of interest. If there is no programmed connection, the device number will be zer… |
| 1.3.6.1.4.1.123.2.11.1.1.10 | ColumnnnciDevSetShowSig | read-write | mandatory | A get from this object will return the current value of signalling, as appropriate for the type of the specified device. When set, the bit pattern supplied wil… |
| 1.3.6.1.4.1.123.2.11.1.1.15 | ColumnnnciDevReady | read-only | mandatory | Whether or not the circuit is ready for use. |
| 1.3.6.1.4.1.123.2.11.1.1.16 | ColumnnnciDevActive | read-only | mandatory | Whether or not the circuit is active. |
| 1.3.6.1.4.1.123.2.11.1.1.17 | ColumnnnciDevConnected | read-only | mandatory | Whether or not the circuit is connected. |
| 1.3.6.1.4.1.123.2.11.1.1.18 | ColumnnnciDevOutOfService | read-only | mandatory | Whether or not the circuit has detected an OutOfService condition. |
| 1.3.6.1.4.1.123.2.11.1.1.21 | ColumnnnciDevUnderMaintenance | read-only | mandatory | True iff the circuit has been subject to a maintenance operation, e.g. a loopback. |
| 1.3.6.1.4.1.123.2.11.1.1.22 | ColumnnnciDevBusyOut | read-write | mandatory | This object is used to remove a circuit from service. |
| 1.3.6.1.4.1.123.2.11.1.1.23 | ColumnnnciDevFailed | read-write | mandatory | True iff this circuit has failed a diagnostics test. |
| 1.3.6.1.4.1.123.2.11.1.1.24 | ColumnnnciDevDiagEnable | read-write | mandatory | Whether or not background diagnostics are enabled for this circuit (if applicable). |
| 1.3.6.1.4.1.123.2.20 | NodennciE1Slot | |||
| 1.3.6.1.4.1.123.2.20.1 | TablennciE1SlotTable | not-accessible | mandatory | This table contains all of the configuration and status information for a E1 interface |
| 1.3.6.1.4.1.123.2.20.1.1 | RownnciE1SlotTableEntry | not-accessible | mandatory | A list of all of the configuration and status information for a E1 interface. |
| 1.3.6.1.4.1.123.2.20.1.1.1 | ColumnnnciE1SlotAlarmControl | read-write | mandatory | This object can be used to control the alarm condition that is indicated by the specified interface. If ForceAISInTS16 is selected, the interface will transmit… |
| 1.3.6.1.4.1.123.2.20.1.1.4 | ColumnnnciE1SlotLoopback | read-write | mandatory | This object is used to set or remove loopbacks on the E1 interface. |
| 1.3.6.1.4.1.123.2.20.1.1.7 | ColumnnnciE1SlotSignalling | read-write | mandatory | This object is used to select either Common Channel Signalling (CCS) or Channel Associated Signalling (CAS) operation for the interface. CCS operation makes ti… |
| 1.3.6.1.4.1.123.2.20.1.1.9 | ColumnnnciE1SlotShieldLevel | read-write | mandatory | This object is used to control the level of the coax shield at the E1 physical interface for each of the receive and transmit lines. The two shields (receive a… |
| 1.3.6.1.4.1.123.2.20.1.1.11 | ColumnnnciE1SlotLinkStatus | read-only | mandatory | This object returns the current 'alarm' state of the E1 interface. |
| 1.3.6.1.4.1.123.2.20.1.1.12 | ColumnnnciE1SlotThreshold | read-write | mandatory | This object controls the system's tolerance of failures on the specified interface. If more than the specified number of failures occurs in one hour, the inter… |
| 1.3.6.1.4.1.123.2.20.1.1.14 | ColumnnnciE1TypeOfStats | read-write | mandatory | The type of stats to be collected for this E1 link. |
| 1.3.6.1.4.1.123.2.20.1.1.21 | ColumnnnciE1SlotTrunkConditioningEnable | read-write | mandatory | This object controls when trunk-conditioning is applied to the specified interface. Trunk- conditioning is the process by which all of the connections to the i… |
| 1.3.6.1.4.1.123.2.20.1.1.22 | ColumnnnciE1SlotAlarmDeclarationTime | read-write | mandatory | This object controls the interval for which the local loss-of-frame condition is debounced. |
| 1.3.6.1.4.1.123.2.20.1.1.23 | ColumnnnciE1SlotAlarmClearingTime | read-write | mandatory | This object controls the interval for which the reacquisition of local frame is debounced. |
| 1.3.6.1.4.1.123.2.20.1.1.25 | ColumnnnciE1SlotCRCFraming | read-write | mandatory | This object controls the generation and use of a Cyclic Redundancy Check during reframing. |
| 1.3.6.1.4.1.123.2.21 | NodennciE1 | |||
| 1.3.6.1.4.1.123.2.21.1 | TablennciE1Table | not-accessible | mandatory | This table contains all of the configuration and status information for a E1 circuit |
| 1.3.6.1.4.1.123.2.21.1.1 | RownnciE1TableEntry | not-accessible | mandatory | A list of all of the configuration and status information for an E1 circuit |
| 1.3.6.1.4.1.123.2.21.1.1.3 | ColumnnnciE1BusyOut | read-write | mandatory | What signalling will be transmitted on the circuit when the circuit is not connected. |
| 1.3.6.1.4.1.123.2.21.1.1.6 | ColumnnnciE1AlternateDigitInversion | read-write | mandatory | Whether or not Alternate Digit Inversion (ADI) will be applied to the data transmitted and received on the circuit. |
| 1.3.6.1.4.1.123.2.21.1.1.9 | ColumnnnciE1DefaultData | read-write | mandatory | The value that is to be transmitted on the circuit when it is not connected. |
| 1.3.6.1.4.1.123.2.21.1.1.10 | ColumnnnciE1FirstCode | read-write | mandatory | The nnciE1FirstCode object is one of two which determines the signalling that will be sent during the Trunk-Conditioning process. This object determines the si… |
| 1.3.6.1.4.1.123.2.21.1.1.11 | ColumnnnciE1SecondCode | read-write | mandatory | The nnciE1SecondCode object is the second of two objects which determines the signalling that will be sent during the Trunk-Conditioning process. This object d… |
| 1.3.6.1.4.1.123.2.21.1.1.13 | ColumnnnciE1PartOfSuperRate | read-write | mandatory | This parameter is used to form a circular linked list of circuit numbers which make up a superrate connection. It contains the circuit number of the next circu… |
| 1.3.6.1.4.1.123.2.21.1.1.14 | ColumnnnciE1BitsUsed | read-write | mandatory | A bitmap which indicates which bits of the E1 circuit are to be used for data. |
| 1.3.6.1.4.1.123.2.21.1.1.21 | ColumnnnciE1SuperRateCircuitMap | read-write | mandatory | When written to, this object builds the circularly-linked list of circuits represented by the one bits in the value written. When read, this object returns the… |
| 1.3.6.1.4.1.123.2.21.1.1.22 | ColumnnnciE1SuperRateNumCircuits | read-write | mandatory | When written to, this object builds the circularly-linked list of circuits to represent the super-rate group which begins at this circuit and contains the spec… |
| 1.3.6.1.4.1.123.2.22 | NodennciT1Slot | |||
| 1.3.6.1.4.1.123.2.22.1 | TablennciT1SlotTable | not-accessible | mandatory | This table contains all of the configuration and status information for a T1 interface. |
| 1.3.6.1.4.1.123.2.22.1.1 | RownnciT1SlotTableEntry | not-accessible | mandatory | A list of all of the configuration and status information for a T1 interface. |
| 1.3.6.1.4.1.123.2.22.1.1.1 | ColumnnnciT1SlotAlarmControl | read-write | mandatory | This object can be used to control the alarm condition that is indicated by the specified interface. If ForceYellow is selected, the interface will provide the… |
| 1.3.6.1.4.1.123.2.22.1.1.2 | ColumnnnciT1SlotFramingStyle | read-write | mandatory | This object is used to select either D4 or ESF framing for the T1 link. |
| 1.3.6.1.4.1.123.2.22.1.1.3 | ColumnnnciT1SlotZeroSuppression | read-write | mandatory | This object is used to select the kind, if any, of zero-code suppression to be used on the link. |
| 1.3.6.1.4.1.123.2.22.1.1.7 | ColumnnnciT1SlotLinkStatus | read-only | mandatory | This object returns the current 'alarm' state of the T1 facility. |
| 1.3.6.1.4.1.123.2.22.1.1.8 | ColumnnnciT1SlotLoopLength | read-write | mandatory | This object is used to control the pre-equalization applied to signal before transmission. |
| 1.3.6.1.4.1.123.2.22.1.1.9 | ColumnnnciT1SlotThreshold | read-write | mandatory | This object controls the system's tolerance of failures on the specified T1 link. If more than the specified number of failures occurs in one hour, the interfa… |
| 1.3.6.1.4.1.123.2.22.1.1.11 | ColumnnnciT1SlotLoopback | read-write | mandatory | This object is used to set or remove loopbacks on the T1 link |
| 1.3.6.1.4.1.123.2.22.1.1.16 | ColumnnnciT1SlotTrunkConditioningEnable | read-write | mandatory | This object controls when trunk-conditioning is applied to the specified T1 link. Trunk- conditioning is the process by which all of the connections to the lin… |
| 1.3.6.1.4.1.123.2.22.1.1.17 | ColumnnnciT1SlotAlarmDeclarationTime | read-write | mandatory | This object controls the interval for which the local loss-of-frame condition is debounced. The debounce algorithm and default value correspond to the requirem… |
| 1.3.6.1.4.1.123.2.22.1.1.18 | ColumnnnciT1SlotAlarmClearingTime | read-write | mandatory | This object controls the interval for which the reacquisition of local frame is debounced. The debounce algorithm and default value correspond to the requireme… |
| 1.3.6.1.4.1.123.2.22.1.1.20 | ColumnnnciT1SlotCRCFraming | read-write | mandatory | This object controls whether a Cyclic Redundancy Check is used when the specified T1 link reframes. This is only applicable to T1 links that a programmed for E… |
| 1.3.6.1.4.1.123.2.23 | NodennciT1 | |||
| 1.3.6.1.4.1.123.2.23.1 | TablennciT1Table | not-accessible | mandatory | This table contains all of the configuration and status information for a T1 circuit |
| 1.3.6.1.4.1.123.2.23.1.1 | RownnciT1TableEntry | not-accessible | mandatory | A list of all of the configuration and status information for an T1 circuit |
| 1.3.6.1.4.1.123.2.23.1.1.1 | ColumnnnciT1BusyOut | read-write | mandatory | What action will be taken on the circuit when the circuit is not connected. |
| 1.3.6.1.4.1.123.2.23.1.1.4 | ColumnnnciT1RobbedBitSig | read-write | mandatory | This object is used to enable or disable Robbed-Bit Signalling for the circuit. |
| 1.3.6.1.4.1.123.2.23.1.1.5 | ColumnnnciT1Inversion | read-write | mandatory | Whether or not data transmitted on this circuit is inverted. |
| 1.3.6.1.4.1.123.2.23.1.1.8 | ColumnnnciT1DefaultData | read-write | mandatory | The value that is to be transmitted on the circuit when it is not connected. |
| 1.3.6.1.4.1.123.2.23.1.1.9 | ColumnnnciT1FirstCode | read-write | mandatory | The nnciT1FirstCode object is one of two which determines the signalling that will be sent during the Trunk-Conditioning process. This object determines the si… |
| 1.3.6.1.4.1.123.2.23.1.1.10 | ColumnnnciT1SecondCode | read-write | mandatory | The nnciT1SecondCode object is the second of two objects which determines the signalling that will be sent during the Trunk-Conditioning process. This object d… |
| 1.3.6.1.4.1.123.2.23.1.1.12 | ColumnnnciT1PartOfSuperRate | read-write | mandatory | This parameter is used to form a circular linked list of circuit numbers which make up a superrate connection It contains the circuit number of the next circui… |
| 1.3.6.1.4.1.123.2.23.1.1.13 | ColumnnnciT1BitsUsed | read-write | mandatory | A bitmap which indicates which bits of the T1 circuit are to be used for data. |
| 1.3.6.1.4.1.123.2.23.1.1.20 | ColumnnnciT1SuperRateCircuitMap | read-write | mandatory | When written to, this object builds the circularly-linked list of circuits represented by the one bits in the value written. When read, this object returns the… |
| 1.3.6.1.4.1.123.2.23.1.1.21 | ColumnnnciT1SuperRateNumCircuits | read-write | mandatory | When written to, this object builds the circularly-linked list of circuits to represent the super-rate group which begins at this circuit and contains the spec… |
| 1.3.6.1.4.1.123.2.55 | NodennciBridge | |||
| 1.3.6.1.4.1.123.2.55.1 | TablennciBridgeTable | not-accessible | mandatory | This table contains all of the configuration information for a Bridge. |
| 1.3.6.1.4.1.123.2.55.1.1 | RownnciBridgeTableEntry | not-accessible | mandatory | A list of all of the configuration information required for a Bridge. |
| 1.3.6.1.4.1.123.2.55.1.1.3 | ColumnnnciBrdgAddress | read-only | mandatory | The data-link layer address to which messages destined for the bridge should be sent. |
| 1.3.6.1.4.1.123.2.55.1.1.4 | ColumnnnciBrdgUptime | read-only | mandatory | The elapsed time in hundredths of a second since the bridge entity was last reset. |
| 1.3.6.1.4.1.123.2.55.1.1.5 | ColumnnnciBrdgInterfaceCount | read-only | mandatory | The number of interfaces which are programmed to be used for/by the bridge. |
| 1.3.6.1.4.1.123.2.55.1.1.6 | ColumnnnciBrdgMaxInterfaceCount | read-only | mandatory | The maximum possible number of interfaces supported by the bridge. |
| 1.3.6.1.4.1.123.2.55.1.1.7 | ColumnnnciBrdgMapCircuitToInterface | read-only | mandatory | Which interface the specified device belongs to. |
| 1.3.6.1.4.1.123.2.61 | NodennciBrdgSt | |||
| 1.3.6.1.4.1.123.2.61.1 | NodennciBridgeStPhase1 | |||
| 1.3.6.1.4.1.123.2.61.1.1 | NodennciBridgeStPhase1GroupOne | |||
| 1.3.6.1.4.1.123.2.61.1.1.4 | ScalarnnciBrdgStFramesFiltered | read-only | mandatory | The number of frames received by the bridge and discarded based on information in the address filter. |
| 1.3.6.1.4.1.123.2.61.1.1.5 | ScalarnnciBrdgStFramesForwarded | read-only | mandatory | The number of frames received by the bridge, not discarded and forwarded to a single destination. |
| 1.3.6.1.4.1.123.2.61.1.1.6 | ScalarnnciBrdgStFramesFlooded | read-only | mandatory | The number of frames received by the bridge, not discarded, but re-transmitted on all interfaces |
| 1.3.6.1.4.1.123.2.61.1.1.11 | ScalarnnciBrdgStTimeSinceLastReset | read-only | mandatory | The elapsed time in hundredths of a second since the bridge's statistical counters were last reset. |
| 1.3.6.1.4.1.123.2.62 | NodennciFilter | |||
| 1.3.6.1.4.1.123.2.62.1 | TablennciFilterTable | not-accessible | mandatory | This table contains all of the configuration and status information related to the filtering mechanism of a Transparent Bridge. |
| 1.3.6.1.4.1.123.2.62.1.1 | RownnciFilterTableEntry | not-accessible | mandatory | A list of all of the configuration and status information related to the filtering mechanism of a Transparent Bridge. |
| 1.3.6.1.4.1.123.2.62.1.1.1 | ColumnnnciFilterReset | read-write | mandatory | This object forces the bridge to reset the filtering database by first removing all of the entries from the filter and then re-initializing it with the entries… |
| 1.3.6.1.4.1.123.2.62.1.1.2 | ColumnnnciFilterLearn | read-write | mandatory | This object determines whether the address filter will learn the source addresses of frames transmitted on networks to which it is directly attached. |
| 1.3.6.1.4.1.123.2.62.1.1.4 | ColumnnnciFilterPermDBChange | read-only | mandatory | This object indicates that the permanent database entries have changed since the last filter reset. |
| 1.3.6.1.4.1.123.2.62.1.1.5 | ColumnnnciFilterPermDBMaxEntries | read-only | mandatory | This object indicates the maximum number of entries that may be placed in the permanent database of the bridge. |
| 1.3.6.1.4.1.123.2.62.1.1.6 | ColumnnnciFilterPermDBEntryCount | read-only | mandatory | This object returns the number of entries currently in the permanent database. |
| 1.3.6.1.4.1.123.2.62.1.1.7 | ColumnnnciFilterPermDBContents | read-only | mandatory | This object provides access to the contents of the permanent database. The modifier is the entry number which can range from 1 to FILTER-PermDBEntryCount. If a… |
| 1.3.6.1.4.1.123.2.62.1.1.8 | ColumnnnciFilterAddPermDBEntry | read-write | mandatory | This object provides a way to add an entry to the permanent database of the bridge. If the maximum size of the permanent database is exceeded, an error will be… |
| 1.3.6.1.4.1.123.2.62.1.1.9 | ColumnnnciFilterDeletePermDBEntry | read-write | mandatory | This object provides a way to delete an entry from the permanent database of the bridge. If the specified entry does not exist, an error will be returned. |
| 1.3.6.1.4.1.123.2.62.1.1.10 | ColumnnnciFilterAFMaxEntries | read-only | mandatory | This object stores the maximum number of entries that may be placed in the address filter. The number includes both entries copied from the permanent database … |
| 1.3.6.1.4.1.123.2.62.1.1.11 | ColumnnnciFilterAFEntryLifetime | read-write | mandatory | This object determined the lifetime of an entry in the address filter. Any entry that is present in the filter but not repeated within n nnciFilterAFEntryLifet… |
| 1.3.6.1.4.1.123.2.62.1.1.12 | ColumnnnciFilterAFEntryCount | read-only | mandatory | This object returns the number of entries currently in the address filter. This can be used in conjunction with nnciFilterAFContents to obtain the current cont… |
| 1.3.6.1.4.1.123.2.62.1.1.13 | ColumnnnciFilterAFContents | read-only | mandatory | This object provides access tot he current contents of the address filter. |
| 1.3.6.1.4.1.123.2.62.1.1.14 | ColumnnnciFilterForwardMatrix | read-write | mandatory | This object determines any restrictions on bridged traffic flow from a particular interface to all of the other interfaces. The restrictions are organized as a… |
| 1.3.6.1.4.1.123.2.62.1.1.15 | ColumnnnciFilterFloodUnicastMatrix | read-write | mandatory | This object determines the handling of a unicast frame with an unrecognized destination. The bridge normally floods such frames on all interfaces except the on… |
| 1.3.6.1.4.1.123.2.62.1.1.17 | ColumnnnciFilterTakeSnapShot | read-write | mandatory | A set with a value of snapshot will make a copy of the address filter that can be accessed by gets from nnciFilterContents |
| 1.3.6.1.4.1.123.2.62.1.1.18 | ColumnnnciFilterFloodMulticastMatrix | read-write | mandatory | This object determines the handling of a multicast frame with an unrecognized destination. The bridge normally floods such frames on all interfaces except the … |
| 1.3.6.1.4.1.123.2.62.1.1.19 | ColumnnnciFilterFloodBroadcastMatrix | read-write | mandatory | This object determines the handling of a broadcast frame with an unrecognized destination. The bridge normally floods such frames on all interfaces except the … |
| 1.3.6.1.4.1.123.2.62.1.1.20 | ColumnnnciFilterPermNVDBContents | read-only | mandatory | This object provides access to the permanent entries stored in NVM, it is used to provide a degree of indirection through the permanent entry vector necessary … |
| 1.3.6.1.4.1.123.2.62.1.1.21 | ColumnnnciFilterDeleteAllPermEntries | read-write | mandatory | This object provides a way to delete all permanent entries from the database in one operation. |
| 1.3.6.1.4.1.123.2.63 | NodennciStp | |||
| 1.3.6.1.4.1.123.2.63.1 | TablennciStpTable | not-accessible | mandatory | This table contains all of the configuration and status information relating to the operation of the 802.1d Spanning Tree Protocol. |
| 1.3.6.1.4.1.123.2.63.1.1 | RownnciStpTableEntry | not-accessible | mandatory | A list of all of the configuration and status information relating to the operation of the 802.1d Spanning Tree Protocol. |
| 1.3.6.1.4.1.123.2.63.1.1.1 | ColumnnnciStpEnable | read-write | mandatory | This object enables or disables the Spanning Tree Protocol. If the protocol is disabled, the bridge acts as a simple bridge, which routes packets based only on… |
| 1.3.6.1.4.1.123.2.63.1.1.2 | ColumnnnciStpBridgePriority | read-write | mandatory | This object determines the role of the bridge in the spanning tree. It is used to decide which bridge in the network should be the root, which bridges should b… |
| 1.3.6.1.4.1.123.2.63.1.1.3 | ColumnnnciStpRoot | read-only | mandatory | This object identifies the bridge that is the root of the spanning tree. |
| 1.3.6.1.4.1.123.2.63.1.1.4 | ColumnnnciStpRootPathCost | read-only | mandatory | This cost of a path is the sum of the costs of the individual hops along the path to the root, where the cost of a hop is a user-assignable object usually rela… |
| 1.3.6.1.4.1.123.2.63.1.1.5 | ColumnnnciStpRootInterface | read-only | mandatory | This object indicates the interface currently used to send messages to the root bridge. It is chosen as the interface which provides the least-cost path to the… |
| 1.3.6.1.4.1.123.2.63.1.1.6 | ColumnnnciStpMaxAge | read-only | mandatory | This object defines the maximum permissible age in seconds of the configuration information held for each interface. If the information becomes older than nnci… |
| 1.3.6.1.4.1.123.2.63.1.1.7 | ColumnnnciStpHelloTime | read-only | mandatory | This object is the value of the HelloTimer used by the root bridge. The present Spanning Tree protocol propogates this value, but the bridges never use it; the… |
| 1.3.6.1.4.1.123.2.63.1.1.8 | ColumnnnciStpForwardDelay | read-only | mandatory | This object defines the number of seconds that an interface is kept in the listening or learning state before being moved to the next state. If a topology chan… |
| 1.3.6.1.4.1.123.2.63.1.1.9 | ColumnnnciStpMyMaxAge | read-write | mandatory | This object is assigned to nnciStpMaxAge if this bridge becomes the root of the spanning tree. |
| 1.3.6.1.4.1.123.2.63.1.1.10 | ColumnnnciStpMyHelloTime | read-write | mandatory | This object is the interval between transmission of configuration BPDUs (also called Hello messages) by the bridge. This object is also assigned to nnciStpHell… |
| 1.3.6.1.4.1.123.2.63.1.1.11 | ColumnnnciStpMyForwardDelay | read-write | mandatory | This object is assigned to nnciStpForwardDelay if this bridge becomes the root of the Spanning Tree. |
| 1.3.6.1.4.1.123.2.63.1.1.12 | ColumnnnciStpTopologyChangeDetected | read-only | mandatory | If this object is true, then this bridge has detected a topology change recently and is sending topology change notifications (TCNs) to the root bridge. |
| 1.3.6.1.4.1.123.2.63.1.1.13 | ColumnnnciStpSendingTopologyChange | read-only | mandatory | If this object is true, then the bridge has recently received a configuration BPDU with the topology change flag set. This indicates that the bridge has been n… |
| 1.3.6.1.4.1.123.2.63.1.1.14 | ColumnnnciStpTimeSinceLastTopologyChange | read-only | mandatory | This object provides the elapsed time in seconds since the last change in network topology. This object is set to zero when a bridge reset occurs. |
| 1.3.6.1.4.1.123.2.63.1.1.15 | ColumnnnciStpTopologyChanges | read-only | mandatory | This object indicates the number of times that the topology change flag has been set to true since the last bridge reset. |
| 1.3.6.1.4.1.123.2.63.1.1.16 | ColumnnnciStpTopologyChangeAck | read-only | mandatory | This flag indicates whether the topology change acknowledge flag should be set in the next hello message generated on this interface. Setting this flag acknowl… |
| 1.3.6.1.4.1.123.2.63.1.1.17 | ColumnnnciStpInterfacePriority | read-write | mandatory | This object is a user-settable priority assigned to each interface. The interface priority allows the network manager to indicate that a given interface should… |
| 1.3.6.1.4.1.123.2.63.1.1.18 | ColumnnnciStpInterfaceCost | read-write | mandatory | This object indicates the relative cost of sending a frame out on a given interface. It is computed in the following manner. If nnciStpCostMultiplier is non-ze… |
| 1.3.6.1.4.1.123.2.63.1.1.19 | ColumnnnciStpDesignatedBridge | read-only | mandatory | This object specifies the designated bridge for the link (LAN or WAN) attached to the interface. Specifically, it is the id of the designated bridge. The desig… |
| 1.3.6.1.4.1.123.2.63.1.1.20 | ColumnnnciStpDesignatedInterface | read-only | mandatory | This object indicates the interface that the bridge given by nnciStpDesignatedBridge uses to send configuration messages over the link (LAN or WAN). Specifical… |
| 1.3.6.1.4.1.123.2.63.1.1.21 | ColumnnnciStpDesignatedRoot | read-only | mandatory | This object indicates who the designated bridge thinks is the root (i.e., what the value of nnciStpRoot is on the bridge given by nnciStpDesignateBridge). This… |
| 1.3.6.1.4.1.123.2.63.1.1.22 | ColumnnnciStpDesignatedCost | read-only | mandatory | This object provides the cost of the cheapest path between nnciStpDesignatedBridge and nnciStpDesignatedRoot. |
| 1.3.6.1.4.1.123.2.63.1.1.23 | ColumnnnciStpConfigurationMessagePending | read-only | mandatory | If this object is true, then a configuration BPDU has been queued for transmission due to the transmission of another configuration BPDU within the last second. |
| 1.3.6.1.4.1.123.2.63.1.1.24 | ColumnnnciStpAllowableDeviations | read-write | mandatory | This object specifies those deviations from the 802.1d document that will be tolerated by the bridge. If the bit in the specified position is 1, then that devi… |
| 1.3.6.1.4.1.123.2.63.1.1.25 | ColumnnnciStpCostMultiplier | read-write | mandatory | This object is the weight assigned to the default cost, expressed as a percentage. That is, a multiplier of 50 means the interface should have half its default… |
| 1.3.6.1.4.1.123.2.63.1.1.26 | ColumnnnciStpUserAssignedCost | read-write | mandatory | This object is used to determine the cost assigned to a interface. See the description of nnciStpInterfaceCost for the details. |
| 1.3.6.1.4.1.123.2.66 | NodennciHdlc | |||
| 1.3.6.1.4.1.123.2.66.1 | TablennciHdlcTable | not-accessible | mandatory | This table contains all of the configuration, status and statistical information required for an HDLC circuit. |
| 1.3.6.1.4.1.123.2.66.1.1 | RownnciHdlcTableEntry | not-accessible | mandatory | A list of all of the configuration, status and statistical information required for an HDLC circuit. |
| 1.3.6.1.4.1.123.2.66.1.1.1 | ColumnnnciHdlcBytesTransmitted | read-only | mandatory | A count of data and padding bytes that were successfully transmitted. |
| 1.3.6.1.4.1.123.2.66.1.1.2 | ColumnnnciHdlcFramesTransmitted | read-only | mandatory | The number of frames that were successfully transmitted. |
| 1.3.6.1.4.1.123.2.66.1.1.3 | ColumnnnciHdlcRxGoodBytes | read-only | mandatory | The number of bytes in frames that were successfully received. |
| 1.3.6.1.4.1.123.2.66.1.1.4 | ColumnnnciHdlcRxGoodFrames | read-only | mandatory | The number of frames that were successfully received. |
| 1.3.6.1.4.1.123.2.66.1.1.5 | ColumnnnciHdlcUnderrun | read-only | mandatory | The number of frames that should have been transmitted by the station, but could not be transmitted due to an internal MAC sublayer transmit error. |
| 1.3.6.1.4.1.123.2.66.1.1.6 | ColumnnnciHdlcCRCError | read-only | mandatory | The number of frames that contained an integral number of bytes but did not pass the frame sequence. |
| 1.3.6.1.4.1.123.2.66.1.1.7 | ColumnnnciHdlcAlignmentError | read-only | mandatory | The number of frames that did not contain an integral number of bytes and did not pass the frame sequence. |
| 1.3.6.1.4.1.123.2.66.1.1.8 | ColumnnnciHdlcOverrun | read-only | mandatory | The number of frames which should have been received by the station, but could not be accepted due to an internal MAC sublayer receive error. |
| 1.3.6.1.4.1.123.2.66.1.1.9 | ColumnnnciHdlcAbort | read-only | mandatory | The number of the number of times that a minimum of seven consecutive ones was received during frame reception. |
| 1.3.6.1.4.1.123.2.66.1.1.11 | ColumnnnciHdlcSinceLastReset | read-only | mandatory | This object indicates the elapsed time in hundredths of a second since the HDLC device's statistical counters were last reset. |
| 1.3.6.1.4.1.123.2.66.1.1.12 | ColumnnnciHdlcApplication | read-only | mandatory | This object indicates the elapsed time in hundredths of a second since the HDLC device's statistical counters were last reset. |
| 1.3.6.1.4.1.123.2.72 | NodennciSdc | |||
| 1.3.6.1.4.1.123.2.72.1 | TablennciSdcTable | not-accessible | mandatory | This table contains all of the configuration and status information for a Synchronous Data Module circuit. |
| 1.3.6.1.4.1.123.2.72.1.1 | RownnciSdcTableEntry | not-accessible | mandatory | A list of all of the configuration and status information required for a Synchronous Data Module circuit. |
| 1.3.6.1.4.1.123.2.72.1.1.1 | ColumnnnciSdcInterfaceControl | read-write | mandatory | Determines the gender (DTE/DCE) of the specified circuit. The gender is used to a) control the operation and interpretation of the control leads and determine … |
| 1.3.6.1.4.1.123.2.72.1.1.2 | ColumnnnciSdcInterfaceSpeed | read-write | mandatory | This object determines the speed of the specified interface in multiples of 800 bits/s. When the interface is in Data Terminal Equipment (DTE) mode (see nnciSd… |
| 1.3.6.1.4.1.123.2.72.1.1.3 | ColumnnnciSdcLeadsDefaultOn | read-write | mandatory | This controls the state of the control leads on the specified interface. The control leads that are affected by this object are determined by a) the type of th… |
| 1.3.6.1.4.1.123.2.72.1.1.4 | ColumnnnciSdcLeadDefaultOff | read-write | mandatory | The interface control leads specified by this object are de-asserted towards the attached equipment. |
| 1.3.6.1.4.1.123.2.72.1.1.5 | ColumnnnciSdcInterfaceStatus | read-write | mandatory | This object reports the current status of the control leads associated with the specified interface. The meanings of the bits reported by this object depend on… |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| AlarmCode | INTEGER (1..255) | ||
| AlarmQueue | INTEGER { major(1), minor(2), diag(3) } | ||
| AlarmQueueIndex | INTEGER (1..64) | ||
| BridgeIdentifier | OCTET STRING (SIZE(8..8)) | ||
| CircuitNumber | INTEGER (1..32) | ||
| ControlLeads | INTEGER (0..255) | ||
| DescendantNumber | INTEGER (1..1023 ) | ||
| DeviceNumber | OCTET STRING | ||
| ExtendedCounter | OCTET STRING (SIZE(8..8)) | ||
| ExtendedTime | OCTET STRING (SIZE(8..8)) | ||
| FilterEntry | OCTET STRING (SIZE(8..8)) | ||
| InterfaceIndex | INTEGER | ||
| ModuleID | INTEGER | ||
| ModuleType | INTEGER | ||
| OneByte | INTEGER (0..255) | ||
| PositionNumber | INTEGER | ||
| SubModuleID | INTEGER | ||
| SubModuleType | INTEGER | ||
| T1E1Loopback | INTEGER { none(1), equipment(2), equipment-all-ones(3), equipment-digital(4), line(5), line-and-equipment(6) } | ||
| T1E1Status | INTEGER (0..65535) |