MIB Viewer

NEWBRIDGE-MIB

234 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.123.2.1NodennciSystem
1.3.6.1.4.1.123.2.1.1TablennciSystemTablenot-accessiblemandatoryThis table contains interesting general information about the managed element in its entirety
1.3.6.1.4.1.123.2.1.1.1RownnciSystemTableEntrynot-accessiblemandatoryA list of general information about the managed element
1.3.6.1.4.1.123.2.1.1.1.2ColumnnnciSystemDateread-writemandatoryThe current date as known by the node.The date is formatted as a sequence of nine ASCII characters in the form DD-MMM-YY, where DD is the day of the month (01.…
1.3.6.1.4.1.123.2.1.1.1.4ColumnnnciSystemProductNameread-onlymandatoryThe marketing name for the product, e.g. 8230 MainStreet for something if sysObjectId.0 = nnci8230
1.3.6.1.4.1.123.2.1.1.1.5ColumnnnciSystemGenericread-onlymandatoryThis object identifies the revision of the firmware in the standard Newbridge fashion. The identifier is a string of 10 ASCII characters of the form M11D-HL-PP…
1.3.6.1.4.1.123.2.1.1.1.30ColumnnnciSystemNVMAllocationread-onlymandatoryThis object provides status information about the non-volatile memory present on the main card of the system. The information returned includes the size of a s…
1.3.6.1.4.1.123.2.1.1.1.31ColumnnnciSystemNVMRepairInforead-onlymandatoryThis object returns the details of the latest repair performed on the non-volatile memory present on the main card.
1.3.6.1.4.1.123.2.1.1.1.38ColumnnnciSystemTimeread-writemandatoryThe current time of day including seconds. The time is represented as a sequence of 9 ASCII characters in the form HH:MM:SS, where HH is the hour of the day (0…
1.3.6.1.4.1.123.2.2NodennciSp
1.3.6.1.4.1.123.2.2.1TablennciSerialPortTablenot-accessiblemandatoryThis table contains the configuration information for an asynchronous management port for a standalone node.
1.3.6.1.4.1.123.2.2.1.1RownnciSerialPortTableEntrynot-accessiblemandatoryA list of configuration information for a management port on a standalone node
1.3.6.1.4.1.123.2.2.1.1.1ColumnnnciSpBaudRateread-writemandatoryThe baud rate of the asynchronous management port.
1.3.6.1.4.1.123.2.2.1.1.2ColumnnnciSpWordLengthread-writemandatoryThe word length used on the asynchronous management port.
1.3.6.1.4.1.123.2.2.1.1.3ColumnnnciSpStopBitsread-writemandatoryThe number of stop bits used by the asynchronous management port.
1.3.6.1.4.1.123.2.2.1.1.4ColumnnnciSpParityread-writemandatoryThe parity used on the asynchronous management port.
1.3.6.1.4.1.123.2.3NodennciDiag
1.3.6.1.4.1.123.2.3.1TablennciDiagTablenot-accessiblemandatoryThis table contains all of the configuration and status information related to diagnostics on a node.
1.3.6.1.4.1.123.2.3.1.1RownnciDiagTableEntrynot-accessiblemandatoryA list of all of the configuration and status information related to node diagnostics.
1.3.6.1.4.1.123.2.3.1.1.1ColumnnnciDiagEnableread-writemandatoryThis object controls whether or not background diagnostics are run. If the object is set to 2 (enabled), then background diagnostics are run periodically. If t…
1.3.6.1.4.1.123.2.3.1.1.5ColumnnnciDiagResultsread-onlymandatoryThis object indicates the results of power on and background diagnostics. Any bit that is asserted corresponds to a failure of a component of the card.
1.3.6.1.4.1.123.2.4NodennciAlarm
1.3.6.1.4.1.123.2.4.1TablennciAlarmTablenot-accessiblemandatoryThis table contains all the configuration and status information about the alarm mechanism along with the alarms themselves.
1.3.6.1.4.1.123.2.4.1.1RownnciAlarmTableEntrynot-accessiblemandatoryA list of all of the configuration and status information for a node, along with the alarm queues themselves.
1.3.6.1.4.1.123.2.4.1.1.1ColumnnnciAlarmCountread-onlymandatoryThe number of alarms in the specified queue.
1.3.6.1.4.1.123.2.4.1.1.2ColumnnnciAlarmQueueEntryread-onlymandatoryWhen read, this object returns the particulars of the entry in the specified queue.
1.3.6.1.4.1.123.2.4.1.1.3ColumnnnciAlarmQueueEntryStatuswrite-onlymandatoryThe status of an alarm.
1.3.6.1.4.1.123.2.4.1.1.4ColumnnnciAlarmSeqNumread-onlymandatoryThe next sequence number that will be used by the node. The sequence numbers are a unique, within a single node, identifier for an alarm.
1.3.6.1.4.1.123.2.4.1.1.6ColumnnnciAlarmCodePriorityread-writemandatoryThis value of this object controls into which queue an alarm is placed.
1.3.6.1.4.1.123.2.4.1.1.8ColumnnnciAlarmDeleteQueueEntrywrite-onlymandatoryA set to this object is deletes the first N alarms from the specified alarm queue.
1.3.6.1.4.1.123.2.4.1.1.9ColumnnnciAlarmQueueTyperead-writemandatoryThis paramater is used to control the behaviour of the alarm queue in the overlfow case, i.e. when the alarm facility attempts to place the 65th alarm into the…
1.3.6.1.4.1.123.2.7NodennciNetSynch
1.3.6.1.4.1.123.2.7.1TablennciNetSynchTablenot-accessiblemandatoryThis table contains all of the configuration and status information for the network synchronization mechanism for a standalone node.
1.3.6.1.4.1.123.2.7.1.1RownnciNetSynchTableEntrynot-accessiblemandatoryA list of all of the configuration and status information related to network synchronization.
1.3.6.1.4.1.123.2.7.1.1.1ColumnnnciNetSynchSourceStatusread-writemandatoryThis object returns the current status of the specified source of synchronization. A set to this object changes the enabled/disabled status of the source. If t…
1.3.6.1.4.1.123.2.7.1.1.2ColumnnnciNetSynchTimingSourceread-writemandatoryThe device which provides timing when the specified source of synchronization is selected. The sync source must be disabled before changing this object.
1.3.6.1.4.1.123.2.7.1.1.3ColumnnnciNetSynchReacquisitionModeread-writemandatoryHow the source of synchronization will be treated in the event a failure is detected. If Manual is selected, the source will remain unused until it is re-selec…
1.3.6.1.4.1.123.2.7.1.1.4ColumnnnciNetSynchCurrentSourceread-writemandatoryThe current source of synchronization for the node. A set to this object toggles the ready/current status of the source. If the source is ready, it will become…
1.3.6.1.4.1.123.2.7.1.1.6ColumnnnciNetSynchRecoveryIntervalread-writemandatoryThis object is used to set the interval between recovery attempts for a source of synchronization that is using Timed recovery in seconds.
1.3.6.1.4.1.123.2.7.1.1.9ColumnnnciNetSynchQualityread-writemandatoryThis object is used to set the maximum permissible number of failures that can be experienced by a source in an hour. If this limit is exceeded, an alarm is ra…
1.3.6.1.4.1.123.2.7.1.1.11ColumnnnciNetSynchSourceClassread-writemandatoryThis object is used to set the class of a source. The source with the best class will provide system sync when several sources are Ready. Note that the freerun…
1.3.6.1.4.1.123.2.7.1.1.12ColumnnnciNetSynchNodeClassread-writemandatoryThis object is used to set the class of the node. The node will freerun if the value of this object is lower than the nnciNetSynchSourceClass of the other sour…
1.3.6.1.4.1.123.2.10NodennciSlot
1.3.6.1.4.1.123.2.10.1TablennciSlotTablenot-accessiblemandatoryThis table contains all of the common, slot configuration and status information for a standalone node
1.3.6.1.4.1.123.2.10.1.1RownnciSlotTableEntrynot-accessiblemandatoryA list of all of the common, per-slot configuration and status information for a standalone node.
1.3.6.1.4.1.123.2.10.1.1.1ColumnnnciSlotNameread-writemandatoryAn arbitrary name for a slot.
1.3.6.1.4.1.123.2.10.1.1.2ColumnnnciSlotProgTyperead-writemandatoryThis object is used to specify what kind of module should be present in the specified position . If the value in this object does not match the value in the nn…
1.3.6.1.4.1.123.2.10.1.1.3ColumnnnciSlotPresTyperead-onlymandatoryThis object is used to specify what kind of module is present in the specified position . If the value of this object does not match the value of the nnciSlotP…
1.3.6.1.4.1.123.2.10.1.1.4ColumnnnciSlotStatusread-writemandatoryThis object contains the current status of the specified position . The status reflects whether a module is present, and if so, is it of the expected type.
1.3.6.1.4.1.123.2.10.1.1.5ColumnnnciSlotModuleIDread-onlymandatoryThe hardware identification number assigned to the module that is present in the specified position. If there is no module installed in the position, the value…
1.3.6.1.4.1.123.2.10.1.1.6ColumnnnciSlotSubModuleProgTyperead-writemandatoryWhat kind of 'sub-module' should be present in the specified slot. If the value in this object does not match the value in the nnciSlotModulePresType object, t…
1.3.6.1.4.1.123.2.10.1.1.7ColumnnnciSlotSubModulePresTyperead-onlymandatoryWhat kind of 'sub-module' is present in the specified position. If the value of this object does not match the value of the nnciSlotModuleProgType object, the …
1.3.6.1.4.1.123.2.10.1.1.8ColumnnnciSlotFirmwareIDread-onlymandatoryThe revision level of the firmware, if any, that is present on a module. If no firmware is present, the value will be zero.
1.3.6.1.4.1.123.2.10.1.1.9ColumnnnciSlotBusyOutread-writemandatoryThis object is used to take circuits on a specified slot out of service. If the value of this object is hold-out-of-service, then the circuits on the slot will…
1.3.6.1.4.1.123.2.10.1.1.10ColumnnnciSlotSubModuleIDread-onlymandatoryThe hardware identification number assigned to the sub-module that is present in the specified position. If there is no sub-module installed in the position, o…
1.3.6.1.4.1.123.2.10.1.1.14ColumnnnciSlotVariantIDread-onlymandatoryThe variant identification number for the module which is installed in the specified slot. If there is no module installed, the value returned will be zero.
1.3.6.1.4.1.123.2.10.1.1.15ColumnnnciSlotResetCardread-writemandatoryThis object is used to cause the node to re-initialize the specified module. Any set to this object will cause the specified module to be re-initialized. If a …
1.3.6.1.4.1.123.2.10.1.1.19ColumnnnciSlotHardwareRevisionread-onlymandatoryThe engineering revision level of the module that occupies the specified position. The high nibble of the returned value is the major revision level and the lo…
1.3.6.1.4.1.123.2.11NodennciDev
1.3.6.1.4.1.123.2.11.1TablennciDevTablenot-accessiblemandatoryThis table contains all of the common, per-device configuration and status information for a circuit. Device-type specific information is found in other tables…
1.3.6.1.4.1.123.2.11.1.1RownnciDevTableEntrynot-accessiblemandatoryA list of all of the common, per-device configuration and status information.
1.3.6.1.4.1.123.2.11.1.1.2ColumnnnciDevNameread-writemandatoryA user-defined name for the specified circuit.
1.3.6.1.4.1.123.2.11.1.1.4ColumnnnciDevLoopbackread-writemandatoryThis object is used to apply and remove loopbacks on the specified circuit. Note that it may not be possible to apply loopbacks to some circuit types.
1.3.6.1.4.1.123.2.11.1.1.5ColumnnnciDevMateDeviceread-onlymandatoryThe device number of the device, if any, that is cross-connected to the device of interest. If there is no programmed connection, the device number will be zer…
1.3.6.1.4.1.123.2.11.1.1.10ColumnnnciDevSetShowSigread-writemandatoryA get from this object will return the current value of signalling, as appropriate for the type of the specified device. When set, the bit pattern supplied wil…
1.3.6.1.4.1.123.2.11.1.1.15ColumnnnciDevReadyread-onlymandatoryWhether or not the circuit is ready for use.
1.3.6.1.4.1.123.2.11.1.1.16ColumnnnciDevActiveread-onlymandatoryWhether or not the circuit is active.
1.3.6.1.4.1.123.2.11.1.1.17ColumnnnciDevConnectedread-onlymandatoryWhether or not the circuit is connected.
1.3.6.1.4.1.123.2.11.1.1.18ColumnnnciDevOutOfServiceread-onlymandatoryWhether or not the circuit has detected an OutOfService condition.
1.3.6.1.4.1.123.2.11.1.1.21ColumnnnciDevUnderMaintenanceread-onlymandatoryTrue iff the circuit has been subject to a maintenance operation, e.g. a loopback.
1.3.6.1.4.1.123.2.11.1.1.22ColumnnnciDevBusyOutread-writemandatoryThis object is used to remove a circuit from service.
1.3.6.1.4.1.123.2.11.1.1.23ColumnnnciDevFailedread-writemandatoryTrue iff this circuit has failed a diagnostics test.
1.3.6.1.4.1.123.2.11.1.1.24ColumnnnciDevDiagEnableread-writemandatoryWhether or not background diagnostics are enabled for this circuit (if applicable).
1.3.6.1.4.1.123.2.20NodennciE1Slot
1.3.6.1.4.1.123.2.20.1TablennciE1SlotTablenot-accessiblemandatoryThis table contains all of the configuration and status information for a E1 interface
1.3.6.1.4.1.123.2.20.1.1RownnciE1SlotTableEntrynot-accessiblemandatoryA list of all of the configuration and status information for a E1 interface.
1.3.6.1.4.1.123.2.20.1.1.1ColumnnnciE1SlotAlarmControlread-writemandatoryThis object can be used to control the alarm condition that is indicated by the specified interface. If ForceAISInTS16 is selected, the interface will transmit…
1.3.6.1.4.1.123.2.20.1.1.4ColumnnnciE1SlotLoopbackread-writemandatoryThis object is used to set or remove loopbacks on the E1 interface.
1.3.6.1.4.1.123.2.20.1.1.7ColumnnnciE1SlotSignallingread-writemandatoryThis object is used to select either Common Channel Signalling (CCS) or Channel Associated Signalling (CAS) operation for the interface. CCS operation makes ti…
1.3.6.1.4.1.123.2.20.1.1.9ColumnnnciE1SlotShieldLevelread-writemandatoryThis object is used to control the level of the coax shield at the E1 physical interface for each of the receive and transmit lines. The two shields (receive a…
1.3.6.1.4.1.123.2.20.1.1.11ColumnnnciE1SlotLinkStatusread-onlymandatoryThis object returns the current 'alarm' state of the E1 interface.
1.3.6.1.4.1.123.2.20.1.1.12ColumnnnciE1SlotThresholdread-writemandatoryThis object controls the system's tolerance of failures on the specified interface. If more than the specified number of failures occurs in one hour, the inter…
1.3.6.1.4.1.123.2.20.1.1.14ColumnnnciE1TypeOfStatsread-writemandatoryThe type of stats to be collected for this E1 link.
1.3.6.1.4.1.123.2.20.1.1.21ColumnnnciE1SlotTrunkConditioningEnableread-writemandatoryThis object controls when trunk-conditioning is applied to the specified interface. Trunk- conditioning is the process by which all of the connections to the i…
1.3.6.1.4.1.123.2.20.1.1.22ColumnnnciE1SlotAlarmDeclarationTimeread-writemandatoryThis object controls the interval for which the local loss-of-frame condition is debounced.
1.3.6.1.4.1.123.2.20.1.1.23ColumnnnciE1SlotAlarmClearingTimeread-writemandatoryThis object controls the interval for which the reacquisition of local frame is debounced.
1.3.6.1.4.1.123.2.20.1.1.25ColumnnnciE1SlotCRCFramingread-writemandatoryThis object controls the generation and use of a Cyclic Redundancy Check during reframing.
1.3.6.1.4.1.123.2.21NodennciE1
1.3.6.1.4.1.123.2.21.1TablennciE1Tablenot-accessiblemandatoryThis table contains all of the configuration and status information for a E1 circuit
1.3.6.1.4.1.123.2.21.1.1RownnciE1TableEntrynot-accessiblemandatoryA list of all of the configuration and status information for an E1 circuit
1.3.6.1.4.1.123.2.21.1.1.3ColumnnnciE1BusyOutread-writemandatoryWhat signalling will be transmitted on the circuit when the circuit is not connected.
1.3.6.1.4.1.123.2.21.1.1.6ColumnnnciE1AlternateDigitInversionread-writemandatoryWhether or not Alternate Digit Inversion (ADI) will be applied to the data transmitted and received on the circuit.
1.3.6.1.4.1.123.2.21.1.1.9ColumnnnciE1DefaultDataread-writemandatoryThe value that is to be transmitted on the circuit when it is not connected.
1.3.6.1.4.1.123.2.21.1.1.10ColumnnnciE1FirstCoderead-writemandatoryThe nnciE1FirstCode object is one of two which determines the signalling that will be sent during the Trunk-Conditioning process. This object determines the si…
1.3.6.1.4.1.123.2.21.1.1.11ColumnnnciE1SecondCoderead-writemandatoryThe nnciE1SecondCode object is the second of two objects which determines the signalling that will be sent during the Trunk-Conditioning process. This object d…
1.3.6.1.4.1.123.2.21.1.1.13ColumnnnciE1PartOfSuperRateread-writemandatoryThis parameter is used to form a circular linked list of circuit numbers which make up a superrate connection. It contains the circuit number of the next circu…
1.3.6.1.4.1.123.2.21.1.1.14ColumnnnciE1BitsUsedread-writemandatoryA bitmap which indicates which bits of the E1 circuit are to be used for data.
1.3.6.1.4.1.123.2.21.1.1.21ColumnnnciE1SuperRateCircuitMapread-writemandatoryWhen written to, this object builds the circularly-linked list of circuits represented by the one bits in the value written. When read, this object returns the…
1.3.6.1.4.1.123.2.21.1.1.22ColumnnnciE1SuperRateNumCircuitsread-writemandatoryWhen written to, this object builds the circularly-linked list of circuits to represent the super-rate group which begins at this circuit and contains the spec…
1.3.6.1.4.1.123.2.22NodennciT1Slot
1.3.6.1.4.1.123.2.22.1TablennciT1SlotTablenot-accessiblemandatoryThis table contains all of the configuration and status information for a T1 interface.
1.3.6.1.4.1.123.2.22.1.1RownnciT1SlotTableEntrynot-accessiblemandatoryA list of all of the configuration and status information for a T1 interface.
1.3.6.1.4.1.123.2.22.1.1.1ColumnnnciT1SlotAlarmControlread-writemandatoryThis object can be used to control the alarm condition that is indicated by the specified interface. If ForceYellow is selected, the interface will provide the…
1.3.6.1.4.1.123.2.22.1.1.2ColumnnnciT1SlotFramingStyleread-writemandatoryThis object is used to select either D4 or ESF framing for the T1 link.
1.3.6.1.4.1.123.2.22.1.1.3ColumnnnciT1SlotZeroSuppressionread-writemandatoryThis object is used to select the kind, if any, of zero-code suppression to be used on the link.
1.3.6.1.4.1.123.2.22.1.1.7ColumnnnciT1SlotLinkStatusread-onlymandatoryThis object returns the current 'alarm' state of the T1 facility.
1.3.6.1.4.1.123.2.22.1.1.8ColumnnnciT1SlotLoopLengthread-writemandatoryThis object is used to control the pre-equalization applied to signal before transmission.
1.3.6.1.4.1.123.2.22.1.1.9ColumnnnciT1SlotThresholdread-writemandatoryThis object controls the system's tolerance of failures on the specified T1 link. If more than the specified number of failures occurs in one hour, the interfa…
1.3.6.1.4.1.123.2.22.1.1.11ColumnnnciT1SlotLoopbackread-writemandatoryThis object is used to set or remove loopbacks on the T1 link
1.3.6.1.4.1.123.2.22.1.1.16ColumnnnciT1SlotTrunkConditioningEnableread-writemandatoryThis object controls when trunk-conditioning is applied to the specified T1 link. Trunk- conditioning is the process by which all of the connections to the lin…
1.3.6.1.4.1.123.2.22.1.1.17ColumnnnciT1SlotAlarmDeclarationTimeread-writemandatoryThis object controls the interval for which the local loss-of-frame condition is debounced. The debounce algorithm and default value correspond to the requirem…
1.3.6.1.4.1.123.2.22.1.1.18ColumnnnciT1SlotAlarmClearingTimeread-writemandatoryThis object controls the interval for which the reacquisition of local frame is debounced. The debounce algorithm and default value correspond to the requireme…
1.3.6.1.4.1.123.2.22.1.1.20ColumnnnciT1SlotCRCFramingread-writemandatoryThis object controls whether a Cyclic Redundancy Check is used when the specified T1 link reframes. This is only applicable to T1 links that a programmed for E…
1.3.6.1.4.1.123.2.23NodennciT1
1.3.6.1.4.1.123.2.23.1TablennciT1Tablenot-accessiblemandatoryThis table contains all of the configuration and status information for a T1 circuit
1.3.6.1.4.1.123.2.23.1.1RownnciT1TableEntrynot-accessiblemandatoryA list of all of the configuration and status information for an T1 circuit
1.3.6.1.4.1.123.2.23.1.1.1ColumnnnciT1BusyOutread-writemandatoryWhat action will be taken on the circuit when the circuit is not connected.
1.3.6.1.4.1.123.2.23.1.1.4ColumnnnciT1RobbedBitSigread-writemandatoryThis object is used to enable or disable Robbed-Bit Signalling for the circuit.
1.3.6.1.4.1.123.2.23.1.1.5ColumnnnciT1Inversionread-writemandatoryWhether or not data transmitted on this circuit is inverted.
1.3.6.1.4.1.123.2.23.1.1.8ColumnnnciT1DefaultDataread-writemandatoryThe value that is to be transmitted on the circuit when it is not connected.
1.3.6.1.4.1.123.2.23.1.1.9ColumnnnciT1FirstCoderead-writemandatoryThe nnciT1FirstCode object is one of two which determines the signalling that will be sent during the Trunk-Conditioning process. This object determines the si…
1.3.6.1.4.1.123.2.23.1.1.10ColumnnnciT1SecondCoderead-writemandatoryThe nnciT1SecondCode object is the second of two objects which determines the signalling that will be sent during the Trunk-Conditioning process. This object d…
1.3.6.1.4.1.123.2.23.1.1.12ColumnnnciT1PartOfSuperRateread-writemandatoryThis parameter is used to form a circular linked list of circuit numbers which make up a superrate connection It contains the circuit number of the next circui…
1.3.6.1.4.1.123.2.23.1.1.13ColumnnnciT1BitsUsedread-writemandatoryA bitmap which indicates which bits of the T1 circuit are to be used for data.
1.3.6.1.4.1.123.2.23.1.1.20ColumnnnciT1SuperRateCircuitMapread-writemandatoryWhen written to, this object builds the circularly-linked list of circuits represented by the one bits in the value written. When read, this object returns the…
1.3.6.1.4.1.123.2.23.1.1.21ColumnnnciT1SuperRateNumCircuitsread-writemandatoryWhen written to, this object builds the circularly-linked list of circuits to represent the super-rate group which begins at this circuit and contains the spec…
1.3.6.1.4.1.123.2.55NodennciBridge
1.3.6.1.4.1.123.2.55.1TablennciBridgeTablenot-accessiblemandatoryThis table contains all of the configuration information for a Bridge.
1.3.6.1.4.1.123.2.55.1.1RownnciBridgeTableEntrynot-accessiblemandatoryA list of all of the configuration information required for a Bridge.
1.3.6.1.4.1.123.2.55.1.1.3ColumnnnciBrdgAddressread-onlymandatoryThe data-link layer address to which messages destined for the bridge should be sent.
1.3.6.1.4.1.123.2.55.1.1.4ColumnnnciBrdgUptimeread-onlymandatoryThe elapsed time in hundredths of a second since the bridge entity was last reset.
1.3.6.1.4.1.123.2.55.1.1.5ColumnnnciBrdgInterfaceCountread-onlymandatoryThe number of interfaces which are programmed to be used for/by the bridge.
1.3.6.1.4.1.123.2.55.1.1.6ColumnnnciBrdgMaxInterfaceCountread-onlymandatoryThe maximum possible number of interfaces supported by the bridge.
1.3.6.1.4.1.123.2.55.1.1.7ColumnnnciBrdgMapCircuitToInterfaceread-onlymandatoryWhich interface the specified device belongs to.
1.3.6.1.4.1.123.2.61NodennciBrdgSt
1.3.6.1.4.1.123.2.61.1NodennciBridgeStPhase1
1.3.6.1.4.1.123.2.61.1.1NodennciBridgeStPhase1GroupOne
1.3.6.1.4.1.123.2.61.1.1.4ScalarnnciBrdgStFramesFilteredread-onlymandatoryThe number of frames received by the bridge and discarded based on information in the address filter.
1.3.6.1.4.1.123.2.61.1.1.5ScalarnnciBrdgStFramesForwardedread-onlymandatoryThe number of frames received by the bridge, not discarded and forwarded to a single destination.
1.3.6.1.4.1.123.2.61.1.1.6ScalarnnciBrdgStFramesFloodedread-onlymandatoryThe number of frames received by the bridge, not discarded, but re-transmitted on all interfaces
1.3.6.1.4.1.123.2.61.1.1.11ScalarnnciBrdgStTimeSinceLastResetread-onlymandatoryThe elapsed time in hundredths of a second since the bridge's statistical counters were last reset.
1.3.6.1.4.1.123.2.62NodennciFilter
1.3.6.1.4.1.123.2.62.1TablennciFilterTablenot-accessiblemandatoryThis table contains all of the configuration and status information related to the filtering mechanism of a Transparent Bridge.
1.3.6.1.4.1.123.2.62.1.1RownnciFilterTableEntrynot-accessiblemandatoryA list of all of the configuration and status information related to the filtering mechanism of a Transparent Bridge.
1.3.6.1.4.1.123.2.62.1.1.1ColumnnnciFilterResetread-writemandatoryThis object forces the bridge to reset the filtering database by first removing all of the entries from the filter and then re-initializing it with the entries…
1.3.6.1.4.1.123.2.62.1.1.2ColumnnnciFilterLearnread-writemandatoryThis object determines whether the address filter will learn the source addresses of frames transmitted on networks to which it is directly attached.
1.3.6.1.4.1.123.2.62.1.1.4ColumnnnciFilterPermDBChangeread-onlymandatoryThis object indicates that the permanent database entries have changed since the last filter reset.
1.3.6.1.4.1.123.2.62.1.1.5ColumnnnciFilterPermDBMaxEntriesread-onlymandatoryThis object indicates the maximum number of entries that may be placed in the permanent database of the bridge.
1.3.6.1.4.1.123.2.62.1.1.6ColumnnnciFilterPermDBEntryCountread-onlymandatoryThis object returns the number of entries currently in the permanent database.
1.3.6.1.4.1.123.2.62.1.1.7ColumnnnciFilterPermDBContentsread-onlymandatoryThis object provides access to the contents of the permanent database. The modifier is the entry number which can range from 1 to FILTER-PermDBEntryCount. If a…
1.3.6.1.4.1.123.2.62.1.1.8ColumnnnciFilterAddPermDBEntryread-writemandatoryThis object provides a way to add an entry to the permanent database of the bridge. If the maximum size of the permanent database is exceeded, an error will be…
1.3.6.1.4.1.123.2.62.1.1.9ColumnnnciFilterDeletePermDBEntryread-writemandatoryThis object provides a way to delete an entry from the permanent database of the bridge. If the specified entry does not exist, an error will be returned.
1.3.6.1.4.1.123.2.62.1.1.10ColumnnnciFilterAFMaxEntriesread-onlymandatoryThis object stores the maximum number of entries that may be placed in the address filter. The number includes both entries copied from the permanent database …
1.3.6.1.4.1.123.2.62.1.1.11ColumnnnciFilterAFEntryLifetimeread-writemandatoryThis object determined the lifetime of an entry in the address filter. Any entry that is present in the filter but not repeated within n nnciFilterAFEntryLifet…
1.3.6.1.4.1.123.2.62.1.1.12ColumnnnciFilterAFEntryCountread-onlymandatoryThis object returns the number of entries currently in the address filter. This can be used in conjunction with nnciFilterAFContents to obtain the current cont…
1.3.6.1.4.1.123.2.62.1.1.13ColumnnnciFilterAFContentsread-onlymandatoryThis object provides access tot he current contents of the address filter.
1.3.6.1.4.1.123.2.62.1.1.14ColumnnnciFilterForwardMatrixread-writemandatoryThis object determines any restrictions on bridged traffic flow from a particular interface to all of the other interfaces. The restrictions are organized as a…
1.3.6.1.4.1.123.2.62.1.1.15ColumnnnciFilterFloodUnicastMatrixread-writemandatoryThis object determines the handling of a unicast frame with an unrecognized destination. The bridge normally floods such frames on all interfaces except the on…
1.3.6.1.4.1.123.2.62.1.1.17ColumnnnciFilterTakeSnapShotread-writemandatoryA set with a value of snapshot will make a copy of the address filter that can be accessed by gets from nnciFilterContents
1.3.6.1.4.1.123.2.62.1.1.18ColumnnnciFilterFloodMulticastMatrixread-writemandatoryThis object determines the handling of a multicast frame with an unrecognized destination. The bridge normally floods such frames on all interfaces except the …
1.3.6.1.4.1.123.2.62.1.1.19ColumnnnciFilterFloodBroadcastMatrixread-writemandatoryThis object determines the handling of a broadcast frame with an unrecognized destination. The bridge normally floods such frames on all interfaces except the …
1.3.6.1.4.1.123.2.62.1.1.20ColumnnnciFilterPermNVDBContentsread-onlymandatoryThis object provides access to the permanent entries stored in NVM, it is used to provide a degree of indirection through the permanent entry vector necessary …
1.3.6.1.4.1.123.2.62.1.1.21ColumnnnciFilterDeleteAllPermEntriesread-writemandatoryThis object provides a way to delete all permanent entries from the database in one operation.
1.3.6.1.4.1.123.2.63NodennciStp
1.3.6.1.4.1.123.2.63.1TablennciStpTablenot-accessiblemandatoryThis table contains all of the configuration and status information relating to the operation of the 802.1d Spanning Tree Protocol.
1.3.6.1.4.1.123.2.63.1.1RownnciStpTableEntrynot-accessiblemandatoryA list of all of the configuration and status information relating to the operation of the 802.1d Spanning Tree Protocol.
1.3.6.1.4.1.123.2.63.1.1.1ColumnnnciStpEnableread-writemandatoryThis object enables or disables the Spanning Tree Protocol. If the protocol is disabled, the bridge acts as a simple bridge, which routes packets based only on…
1.3.6.1.4.1.123.2.63.1.1.2ColumnnnciStpBridgePriorityread-writemandatoryThis object determines the role of the bridge in the spanning tree. It is used to decide which bridge in the network should be the root, which bridges should b…
1.3.6.1.4.1.123.2.63.1.1.3ColumnnnciStpRootread-onlymandatoryThis object identifies the bridge that is the root of the spanning tree.
1.3.6.1.4.1.123.2.63.1.1.4ColumnnnciStpRootPathCostread-onlymandatoryThis cost of a path is the sum of the costs of the individual hops along the path to the root, where the cost of a hop is a user-assignable object usually rela…
1.3.6.1.4.1.123.2.63.1.1.5ColumnnnciStpRootInterfaceread-onlymandatoryThis object indicates the interface currently used to send messages to the root bridge. It is chosen as the interface which provides the least-cost path to the…
1.3.6.1.4.1.123.2.63.1.1.6ColumnnnciStpMaxAgeread-onlymandatoryThis object defines the maximum permissible age in seconds of the configuration information held for each interface. If the information becomes older than nnci…
1.3.6.1.4.1.123.2.63.1.1.7ColumnnnciStpHelloTimeread-onlymandatoryThis object is the value of the HelloTimer used by the root bridge. The present Spanning Tree protocol propogates this value, but the bridges never use it; the…
1.3.6.1.4.1.123.2.63.1.1.8ColumnnnciStpForwardDelayread-onlymandatoryThis object defines the number of seconds that an interface is kept in the listening or learning state before being moved to the next state. If a topology chan…
1.3.6.1.4.1.123.2.63.1.1.9ColumnnnciStpMyMaxAgeread-writemandatoryThis object is assigned to nnciStpMaxAge if this bridge becomes the root of the spanning tree.
1.3.6.1.4.1.123.2.63.1.1.10ColumnnnciStpMyHelloTimeread-writemandatoryThis object is the interval between transmission of configuration BPDUs (also called Hello messages) by the bridge. This object is also assigned to nnciStpHell…
1.3.6.1.4.1.123.2.63.1.1.11ColumnnnciStpMyForwardDelayread-writemandatoryThis object is assigned to nnciStpForwardDelay if this bridge becomes the root of the Spanning Tree.
1.3.6.1.4.1.123.2.63.1.1.12ColumnnnciStpTopologyChangeDetectedread-onlymandatoryIf this object is true, then this bridge has detected a topology change recently and is sending topology change notifications (TCNs) to the root bridge.
1.3.6.1.4.1.123.2.63.1.1.13ColumnnnciStpSendingTopologyChangeread-onlymandatoryIf this object is true, then the bridge has recently received a configuration BPDU with the topology change flag set. This indicates that the bridge has been n…
1.3.6.1.4.1.123.2.63.1.1.14ColumnnnciStpTimeSinceLastTopologyChangeread-onlymandatoryThis object provides the elapsed time in seconds since the last change in network topology. This object is set to zero when a bridge reset occurs.
1.3.6.1.4.1.123.2.63.1.1.15ColumnnnciStpTopologyChangesread-onlymandatoryThis object indicates the number of times that the topology change flag has been set to true since the last bridge reset.
1.3.6.1.4.1.123.2.63.1.1.16ColumnnnciStpTopologyChangeAckread-onlymandatoryThis flag indicates whether the topology change acknowledge flag should be set in the next hello message generated on this interface. Setting this flag acknowl…
1.3.6.1.4.1.123.2.63.1.1.17ColumnnnciStpInterfacePriorityread-writemandatoryThis object is a user-settable priority assigned to each interface. The interface priority allows the network manager to indicate that a given interface should…
1.3.6.1.4.1.123.2.63.1.1.18ColumnnnciStpInterfaceCostread-writemandatoryThis object indicates the relative cost of sending a frame out on a given interface. It is computed in the following manner. If nnciStpCostMultiplier is non-ze…
1.3.6.1.4.1.123.2.63.1.1.19ColumnnnciStpDesignatedBridgeread-onlymandatoryThis object specifies the designated bridge for the link (LAN or WAN) attached to the interface. Specifically, it is the id of the designated bridge. The desig…
1.3.6.1.4.1.123.2.63.1.1.20ColumnnnciStpDesignatedInterfaceread-onlymandatoryThis object indicates the interface that the bridge given by nnciStpDesignatedBridge uses to send configuration messages over the link (LAN or WAN). Specifical…
1.3.6.1.4.1.123.2.63.1.1.21ColumnnnciStpDesignatedRootread-onlymandatoryThis object indicates who the designated bridge thinks is the root (i.e., what the value of nnciStpRoot is on the bridge given by nnciStpDesignateBridge). This…
1.3.6.1.4.1.123.2.63.1.1.22ColumnnnciStpDesignatedCostread-onlymandatoryThis object provides the cost of the cheapest path between nnciStpDesignatedBridge and nnciStpDesignatedRoot.
1.3.6.1.4.1.123.2.63.1.1.23ColumnnnciStpConfigurationMessagePendingread-onlymandatoryIf this object is true, then a configuration BPDU has been queued for transmission due to the transmission of another configuration BPDU within the last second.
1.3.6.1.4.1.123.2.63.1.1.24ColumnnnciStpAllowableDeviationsread-writemandatoryThis object specifies those deviations from the 802.1d document that will be tolerated by the bridge. If the bit in the specified position is 1, then that devi…
1.3.6.1.4.1.123.2.63.1.1.25ColumnnnciStpCostMultiplierread-writemandatoryThis object is the weight assigned to the default cost, expressed as a percentage. That is, a multiplier of 50 means the interface should have half its default…
1.3.6.1.4.1.123.2.63.1.1.26ColumnnnciStpUserAssignedCostread-writemandatoryThis object is used to determine the cost assigned to a interface. See the description of nnciStpInterfaceCost for the details.
1.3.6.1.4.1.123.2.66NodennciHdlc
1.3.6.1.4.1.123.2.66.1TablennciHdlcTablenot-accessiblemandatoryThis table contains all of the configuration, status and statistical information required for an HDLC circuit.
1.3.6.1.4.1.123.2.66.1.1RownnciHdlcTableEntrynot-accessiblemandatoryA list of all of the configuration, status and statistical information required for an HDLC circuit.
1.3.6.1.4.1.123.2.66.1.1.1ColumnnnciHdlcBytesTransmittedread-onlymandatoryA count of data and padding bytes that were successfully transmitted.
1.3.6.1.4.1.123.2.66.1.1.2ColumnnnciHdlcFramesTransmittedread-onlymandatoryThe number of frames that were successfully transmitted.
1.3.6.1.4.1.123.2.66.1.1.3ColumnnnciHdlcRxGoodBytesread-onlymandatoryThe number of bytes in frames that were successfully received.
1.3.6.1.4.1.123.2.66.1.1.4ColumnnnciHdlcRxGoodFramesread-onlymandatoryThe number of frames that were successfully received.
1.3.6.1.4.1.123.2.66.1.1.5ColumnnnciHdlcUnderrunread-onlymandatoryThe number of frames that should have been transmitted by the station, but could not be transmitted due to an internal MAC sublayer transmit error.
1.3.6.1.4.1.123.2.66.1.1.6ColumnnnciHdlcCRCErrorread-onlymandatoryThe number of frames that contained an integral number of bytes but did not pass the frame sequence.
1.3.6.1.4.1.123.2.66.1.1.7ColumnnnciHdlcAlignmentErrorread-onlymandatoryThe number of frames that did not contain an integral number of bytes and did not pass the frame sequence.
1.3.6.1.4.1.123.2.66.1.1.8ColumnnnciHdlcOverrunread-onlymandatoryThe number of frames which should have been received by the station, but could not be accepted due to an internal MAC sublayer receive error.
1.3.6.1.4.1.123.2.66.1.1.9ColumnnnciHdlcAbortread-onlymandatoryThe number of the number of times that a minimum of seven consecutive ones was received during frame reception.
1.3.6.1.4.1.123.2.66.1.1.11ColumnnnciHdlcSinceLastResetread-onlymandatoryThis object indicates the elapsed time in hundredths of a second since the HDLC device's statistical counters were last reset.
1.3.6.1.4.1.123.2.66.1.1.12ColumnnnciHdlcApplicationread-onlymandatoryThis object indicates the elapsed time in hundredths of a second since the HDLC device's statistical counters were last reset.
1.3.6.1.4.1.123.2.72NodennciSdc
1.3.6.1.4.1.123.2.72.1TablennciSdcTablenot-accessiblemandatoryThis table contains all of the configuration and status information for a Synchronous Data Module circuit.
1.3.6.1.4.1.123.2.72.1.1RownnciSdcTableEntrynot-accessiblemandatoryA list of all of the configuration and status information required for a Synchronous Data Module circuit.
1.3.6.1.4.1.123.2.72.1.1.1ColumnnnciSdcInterfaceControlread-writemandatoryDetermines the gender (DTE/DCE) of the specified circuit. The gender is used to a) control the operation and interpretation of the control leads and determine …
1.3.6.1.4.1.123.2.72.1.1.2ColumnnnciSdcInterfaceSpeedread-writemandatoryThis object determines the speed of the specified interface in multiples of 800 bits/s. When the interface is in Data Terminal Equipment (DTE) mode (see nnciSd…
1.3.6.1.4.1.123.2.72.1.1.3ColumnnnciSdcLeadsDefaultOnread-writemandatoryThis controls the state of the control leads on the specified interface. The control leads that are affected by this object are determined by a) the type of th…
1.3.6.1.4.1.123.2.72.1.1.4ColumnnnciSdcLeadDefaultOffread-writemandatoryThe interface control leads specified by this object are de-asserted towards the attached equipment.
1.3.6.1.4.1.123.2.72.1.1.5ColumnnnciSdcInterfaceStatusread-writemandatoryThis object reports the current status of the control leads associated with the specified interface. The meanings of the bits reported by this object depend on…
Type Definitions
NameSyntaxStatusDescription
AlarmCodeINTEGER (1..255)
AlarmQueueINTEGER { major(1), minor(2), diag(3) }
AlarmQueueIndexINTEGER (1..64)
BridgeIdentifierOCTET STRING (SIZE(8..8))
CircuitNumberINTEGER (1..32)
ControlLeadsINTEGER (0..255)
DescendantNumberINTEGER (1..1023 )
DeviceNumberOCTET STRING
ExtendedCounterOCTET STRING (SIZE(8..8))
ExtendedTimeOCTET STRING (SIZE(8..8))
FilterEntryOCTET STRING (SIZE(8..8))
InterfaceIndexINTEGER
ModuleIDINTEGER
ModuleTypeINTEGER
OneByteINTEGER (0..255)
PositionNumberINTEGER
SubModuleIDINTEGER
SubModuleTypeINTEGER
T1E1LoopbackINTEGER { none(1), equipment(2), equipment-all-ones(3), equipment-digital(4), line(5), line-and-equipment(6) }
T1E1StatusINTEGER (0..65535)