MIB Viewer

NOKIA-HWM-MIB

22 objects
The MIB module that is used to control the Hardware Management information.
Imported Objects
ENTITY-MIBentPhysicalDescr entPhysicalIndex -- entPhysicalVendorType
NOKIA-COMMON-MIB-OID-REGISTRATION-MIBntcCommonModules ntcHWMibs ntcHWReqs
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP -- NOTIFICATION-GROUP
SNMPv2-SMIInteger32 -- NOTIFICATION-TYPE MODULE-IDENTITY OBJECT-TYPE
SNMPv2-TCAutonomousType -- DateAndTime DisplayString TimeStamp
OIDNameAccessStatusDescription
1.3.6.1.4.1.94.1.16.5.1IdentityntcHWModuleThe MIB module that is used to control the Hardware Management information.
1.3.6.1.4.1.94.1.16.7.1.1NodentcHWObjs
1.3.6.1.4.1.94.1.16.7.1.1.1TablentcHWUnitTablenot-accessiblecurrentA table which contains an entry for each pluggable circuit board (in this MIB a 'unit' is the same as a pluggable circuit board.) Entries of this table are aut…
1.3.6.1.4.1.94.1.16.7.1.1.1.1RowntcHWUnitEntrynot-accessiblecurrentA conceptual row in the ntcHWUnitTable. Rows are created automatically by the Hardware Management software.
1.3.6.1.4.1.94.1.16.7.1.1.1.1.1ColumnntcHWAdminStateread-writecurrentRepresents the desired state of the unit. inService indicates that the unit is intended to be operating normally. outOfService indicates that the unit should b…
1.3.6.1.4.1.94.1.16.7.1.1.1.1.2ColumnntcHWOperStateread-onlycurrentIndicates the current state of the unit. down indicates that the unit is in a non-functional state. up indicates that the unit is functioning normally.
1.3.6.1.4.1.94.1.16.7.1.1.1.1.3ColumnntcHWAvailabilityStatusread-onlycurrentProvides more specific information on the state of the unit in this conceptual row. The status column has eleven defined values: inCharge = the unit is fully o…
1.3.6.1.4.1.94.1.16.7.1.1.1.1.4ColumnntcHWRestartread-writecurrentProvides the ability to reset or perform a hot restart the unit represented by this conceptual row. reset = the Unit is shutdown in an orderly manner and resta…
1.3.6.1.4.1.94.1.16.7.1.1.1.1.5ColumnntcHWLedStateread-onlycurrentIndicates the current LED color of the unit represented by this conceptual row.
1.3.6.1.4.1.94.1.16.7.1.1.1.1.6ColumnntcHWSerialNumberread-onlycurrentThe units serial number in displayable format.
1.3.6.1.4.1.94.1.16.7.1.1.1.1.7ColumnntcHWProductionDateread-onlycurrentThe units production date in displayable format.
1.3.6.1.4.1.94.1.16.7.1.1.1.1.8ColumnntcHWUnitEntryChangedread-onlycurrentRepresents the value of sysUpTime at the instant that this conceptual row entry has changed.
1.3.6.1.4.1.94.1.16.7.1.1.2TablentcHWSlotTablenot-accessiblecurrentTable whose entries represent the expected circuit board type. The entries are created automatically by the hardware management software.
1.3.6.1.4.1.94.1.16.7.1.1.2.1RowntcHWSlotEntrynot-accessiblecurrentThe logical row describing the expected circiut board type of a slot.
1.3.6.1.4.1.94.1.16.7.1.1.2.1.2ColumnntcHWDesiredUnitTyperead-writecurrentThe unit type which is expected to be inserted or present in the current slot. An indication of the vendor-specific hardware type of the HWM entity. Note that …
1.3.6.1.4.1.94.1.16.7.1.1.3ScalarntcHWLastChangedTimeread-onlycurrentThe value of sysUpTime at the time any of these events occur: * any instance in the following object changes value: - hwmUnitEntryChanged This object shall be …
1.3.6.1.4.1.94.1.16.7.1.1.4ScalarntcHWLoadInventoryContainerread-writecurrentWriting any value to this object will cause the hardware management software to reread its configuration file from disk.
1.3.6.1.4.1.94.1.16.7.1.2.0NodentcHWEvents
1.3.6.1.4.1.94.1.16.8.1.1NodentcHWGroups
1.3.6.1.4.1.94.1.16.8.1.1.1GroupntcHWUnitscurrentA collection of objects representing the status of a unit.
1.3.6.1.4.1.94.1.16.8.1.2NodentcHWCompliances
1.3.6.1.4.1.94.1.16.8.1.2.1CompliancentcHWCompliancecurrentThe compliance statement Hardware Management.