1.3.6.1.4.1.562.36.2.1.3.2NodemscAlarmTrap
1.3.6.1.4.1.562.36.2.1.3.2.1NodemscCriticalAlarmThis trap is used to provide a real time indication of a critical Alarm condition. The variables listed in the VARIABLES clause, defined in the `mscMandatoryAl…
1.3.6.1.4.1.562.36.2.1.3.2.2NodemscMajorAlarmThis trap is used to provide a real time indication of a major Alarm condition. The variables listed in the VARIABLES clause, defined in the `mscMandatoryAlarm…
1.3.6.1.4.1.562.36.2.1.3.2.3NodemscMinorAlarmThis trap is used to provide a real time indication of a minor Alarm condition. The variables listed in the VARIABLES clause, defined in the `mscMandatoryAlarm…
1.3.6.1.4.1.562.36.2.1.3.2.4NodemscWarningAlarmThis trap is used to provide a real time indication of a warning Alarm condition. The variables listed in the VARIABLES clause, defined in the `mscMandatoryAla…
1.3.6.1.4.1.562.36.2.1.3.2.5NodemscClearedAlarmThis trap is used to provide a real time indication of a cleared Alarm. The variables listed in the VARIABLES clause, defined in the `mscMandatoryAlarmInfo' gr…
1.3.6.1.4.1.562.36.2.1.3.2.6NodemscIndeterminateAlarmThis trap is used to provide a real time indication of an indeterminate Alarm condition. The variables listed in the VARIABLES clause, defined in the `mscManda…
1.3.6.1.4.1.562.36.2.1.3.2.7NodemscMandatoryAlarmInfo
1.3.6.1.4.1.562.36.2.1.3.2.7.1ScalarmscComponentRowPointernot-accessiblemandatoryA pointer to the RowStatus variable of the component emitting the alarm.
1.3.6.1.4.1.562.36.2.1.3.2.7.2ScalarmscComponentNamenot-accessiblemandatoryThe textual name of the component emitting the alarm in a format suitable for use in commands entered on the `console'. It includes the name of the node from w…
1.3.6.1.4.1.562.36.2.1.3.2.7.3ScalarmscEventTimenot-accessiblemandatoryThe date and time at which the alarmed event occurred.
1.3.6.1.4.1.562.36.2.1.3.2.7.4ScalarmscActiveListStatusnot-accessiblemandatoryThe active alarm list status. This may be used by the Manager to add (on receiving a set) and delete (on receiving a clear) alarms from the alarm displays.
1.3.6.1.4.1.562.36.2.1.3.2.7.5ScalarmscSeveritynot-accessiblemandatoryThe severity of the alarm which should indicate what priority that fixing this problem should be given. All values are OSI-defined; refer to CCITT X.733/ISO 10…
1.3.6.1.4.1.562.36.2.1.3.2.7.6ScalarmscAlarmTypenot-accessiblemandatoryThe alarm type field as defined by OSI which is used to indicate a broad category of what is wrong. The first 6 values are OSI-defined; refer to CCITT X.733/IS…
1.3.6.1.4.1.562.36.2.1.3.2.7.7ScalarmscProbableCausenot-accessiblemandatoryThe probable cause for the alarm which usually qualifies the Alarm Type field. Most values are OSI-defined; refer refer to CCITT X.733 and X.736 (ISO 10164-4 a…
1.3.6.1.4.1.562.36.2.1.3.2.7.8ScalarmscNtpIndexnot-accessiblemandatoryAn 8-digit code which is an index into an NTP to provide more description of the alarm and possible actions to take. The first 4 digits indicate a 'group' of a…
1.3.6.1.4.1.562.36.2.1.3.2.7.9ScalarmscCommentDatanot-accessiblemandatoryAdditional textual information for the network operator to use. It contains only ASCII characters. Note: The total number of bytes in mscCommentData, mscOperat…
1.3.6.1.4.1.562.36.2.1.3.2.8NodemscOptionalAlarmInfo
1.3.6.1.4.1.562.36.2.1.3.2.8.1ScalarmscNotificationIDnot-accessiblemandatoryThe notification Id of the alarm. The high-order byte is the card number of the card from which this alarm originated. The low-order 24 bits contain a sequence…
1.3.6.1.4.1.562.36.2.1.3.2.8.2ScalarmscLpForHierClearnot-accessiblemandatoryA pointer to the RowStatus variable of the Logical Processor the component generating the alarm is running on. A component generating an Alarm with `mscActiveL…
1.3.6.1.4.1.562.36.2.1.3.2.8.3ScalarmscOperatorDatanot-accessiblemandatoryAdditional hexadecimal information for the network operator to use. Note: The total number of bytes in mscCommentData, mscOperatorData, and mscInternalData may…
1.3.6.1.4.1.562.36.2.1.3.2.8.4ScalarmscPidnot-accessiblemandatoryA string representation of the internal process id (Pid) of the process which generated the alarm (for internal use only). Note that it may or may not map to t…
1.3.6.1.4.1.562.36.2.1.3.2.8.5ScalarmscFileNamenot-accessiblemandatoryAn internal filename (for internal use only).
1.3.6.1.4.1.562.36.2.1.3.2.8.6ScalarmscFileLineNumbernot-accessiblemandatoryAn internal line number in the file (see filename) referred to above (for internal use only).
1.3.6.1.4.1.562.36.2.1.3.2.8.7ScalarmscFileVersionnot-accessiblemandatoryA version indicator of the file (filename) referred to above (for internal use only).
1.3.6.1.4.1.562.36.2.1.3.2.8.8ScalarmscInternalDatanot-accessiblemandatoryAn additional internal hexadecimal information for internal use only. Note: The total number of bytes in comment, operator, and internal data may not exceed 75…
1.3.6.1.4.1.562.36.2.1.3.2.9NodemscProvisionalAlarmInfo
1.3.6.1.4.1.562.36.2.1.3.2.9.1ScalarmscCidnot-accessiblemandatoryThis is a Custom Identifier(CID) of the component which generated the alarm
1.3.6.1.4.1.562.36.2.2.4NodealarmMIB
1.3.6.1.4.1.562.36.2.2.4.1NodealarmGroup
1.3.6.1.4.1.562.36.2.2.4.1.1NodealarmGroupCA
1.3.6.1.4.1.562.36.2.2.4.1.1.2NodealarmGroupCA01
1.3.6.1.4.1.562.36.2.2.4.1.1.2.2NodealarmGroupCA01A
1.3.6.1.4.1.562.36.2.2.4.2NodealarmNotifications
1.3.6.1.4.1.562.36.2.2.4.2.1NodealarmNotificationsGroupCA01A
1.3.6.1.4.1.562.36.2.2.4.3NodealarmCapabilities
1.3.6.1.4.1.562.36.2.2.4.3.1NodealarmCapabilitiesCA
1.3.6.1.4.1.562.36.2.2.4.3.1.2NodealarmCapabilitiesCA01
1.3.6.1.4.1.562.36.2.2.4.3.1.2.2NodealarmCapabilitiesCA01A