MIB Viewer

Novell-LANtern-Admin-MIB

64 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.23Nodenovell
1.3.6.1.4.1.23.1NodeproductType
1.3.6.1.4.1.23.1.1NodenetworkMonitor
1.3.6.1.4.1.23.1.1.1NodeethernetLANtern
1.3.6.1.4.1.23.2NodemibDoc
1.3.6.1.4.1.23.2.1Nodelantern
1.3.6.1.4.1.23.2.1.1NodelanternAdmin
1.3.6.1.4.1.23.2.1.1.1ScalaradminIdentificationread-writemandatoryAn identifying ASCII string may be attached to the LANtern network monitor by writing adminIdentification. Conversely, the LANtern network monitor may be ident…
1.3.6.1.4.1.23.2.1.1.2ScalaradminDateAndTimeread-writemandatoryReading adminDateAndTime returns the current date and time in use by the LANtern network monitor. The LANtern network monitor's date and time may be adjusted a…
1.3.6.1.4.1.23.2.1.1.3ScalaradminTimeZoneread-writemandatoryA DisplayString defining the time zone of the LANtern network monitor. adminTimeZone is neither parsed nor used by the LANtern network monitor, it is merely st…
1.3.6.1.4.1.23.2.1.1.4ScalaradminPowerOnTimeread-onlymandatoryThe date and time when the LANtern network monitor was last powered on or restarted.
1.3.6.1.4.1.23.2.1.1.5ScalaradminPowerOffTimeread-onlymandatoryThe date and time when the LANtern network monitor was last powered off or restarted. The value is 0 (midnight, 1 January 1900) after a cold start.
1.3.6.1.4.1.23.2.1.1.6ScalaradminNetworkDataLinkread-writemandatoryThe type of data link encapsulation to be used on the monitored network. adminNetworkDataLink may be written at any time; however, the change does not take eff…
1.3.6.1.4.1.23.2.1.1.7ScalaradminNetworkIPAddrread-writemandatoryThe IP address to be used by the LANtern network monitor on the monitored network. adminNetworkIPAddr may be written at any time; however, the change does not …
1.3.6.1.4.1.23.2.1.1.8ScalaradminNetworkSubnetMaskread-writemandatoryThe subnet mask for the monitored network. adminNetworkSubnetMask may be written at any time; however, the change does not take effect until the LANtern networ…
1.3.6.1.4.1.23.2.1.1.9ScalaradminNetworkGatewayread-writemandatoryThe IP address of a gateway directly connected to the monitored network (the LANtern network monitor's default gateway). adminNetworkGateway may be written at …
1.3.6.1.4.1.23.2.1.1.10TableadminClientTablenot-accessiblemandatoryA table providing data on all authorized LANtern clients. The table is accessed by adminClientIPAddr. A new entry may be created by writing to a nonexistent in…
1.3.6.1.4.1.23.2.1.1.10.1RowadminClientEntrynot-accessiblemandatoryData about each authorized client.
1.3.6.1.4.1.23.2.1.1.10.1.1ColumnadminClientIPAddrread-onlymandatoryThe IP address (or portion thereof) of a station authorized to access the LANtern network monitor.
1.3.6.1.4.1.23.2.1.1.10.1.2ColumnadminClientIPMaskread-writemandatoryA 32-bit mask that is bitwise anded with the candidate client's IP address before attempting to match against adminClientIPAddr.
1.3.6.1.4.1.23.2.1.1.10.1.3ColumnadminClientCommunitiesread-writemandatoryA bit array where the presence of a particular bit indicates that use of that particular community name is permitted. Bit Community 2^0 administrator 2^1 logge…
1.3.6.1.4.1.23.2.1.1.10.1.4ColumnadminClientDeletewrite-onlymandatoryA write (any value) causes the table entry to be deleted.
1.3.6.1.4.1.23.2.1.1.11ScalaradminUnauthorizedIPAddrnot-accessiblemandatoryThe IP address of the station that generated the authentication failure.
1.3.6.1.4.1.23.2.1.1.12ScalaradminUnauthorizedCommunitynot-accessiblemandatoryThe community name string used in the PDU that generated the authentication failure.
1.3.6.1.4.1.23.2.1.1.13TableadminNotificationTablenot-accessiblemandatoryA list of all stations wishing to receive traps from the LANtern network monitor; accessed by adminNotificationIPAddr. A new entry may be created by writing to…
1.3.6.1.4.1.23.2.1.1.13.1RowadminNotificationEntrynot-accessiblemandatoryData for each station on the notification list.
1.3.6.1.4.1.23.2.1.1.13.1.1ColumnadminNotificationIPAddrread-onlymandatoryThe IP address of the station wishing to receive traps from the LANtern network monitor.
1.3.6.1.4.1.23.2.1.1.13.1.2ColumnadminNotificationStatusread-writemandatoryTraps are sent to all primaryContacts who have the corresponding bit set in adminNotificationTrapMask. Traps are sent to backupContacts only if they have the c…
1.3.6.1.4.1.23.2.1.1.13.1.3ColumnadminNotificationTrapMaskread-writemandatoryA bit array specifying which traps the station wishes to receive. Bit Trap 2^0 warmStart 2^1 cableFailure 2^2 reserved 2^3 duplicateIPAddr 2^4 utilizationAlarm…
1.3.6.1.4.1.23.2.1.1.13.1.4ColumnadminNotificationConfirmMaskread-writemandatoryA bit array specifying which traps the station wishes to receive with confirmed delivery. Any bits set must also be set in adminNotificationTrapMask. If a trap…
1.3.6.1.4.1.23.2.1.1.13.1.5ColumnadminNotificationTimeoutread-writemandatoryFor traps with confirmed delivery, adminNotificationTimeout specifies the interval (in seconds) between retries.
1.3.6.1.4.1.23.2.1.1.13.1.6ColumnadminNotificationRetriesread-writemandatoryFor traps with confirmed delivery, adminNotificationRetries specifies the number of retries that should be attempted before giving up and trying to deliver the…
1.3.6.1.4.1.23.2.1.1.13.1.7ColumnadminNotificationBackupIPAddrread-writemandatoryFor traps with confirmed delivery, adminNotificationBackupIPAddr specifies the IP address of a backup station (also in adminNotificationTable) to be contacted …
1.3.6.1.4.1.23.2.1.1.13.1.8ColumnadminNotificationDeletewrite-onlymandatoryA write (any value) causes the table entry to be deleted.
1.3.6.1.4.1.23.2.1.1.14ScalaradminTrapHandlenot-accessiblemandatoryA unique handle that is generated for each trap issued and that is passed in the trap-PDU along with any other variable bindings.
1.3.6.1.4.1.23.2.1.1.15ScalaradminTrapAcknowledgewrite-onlymandatoryA trap is acknowledged by writing the value of adminTrapHandle passed in the trap-PDU to adminTrapAcknowledge.
1.3.6.1.4.1.23.2.1.1.16ScalaradminDownLoadFileread-writemandatoryThe name of the executable file to be downloaded from adminDownLoadServer.
1.3.6.1.4.1.23.2.1.1.17ScalaradminDownLoadServerread-writemandatoryThe name of the file server from which to download a new executable image (adminDownLoadFile).
1.3.6.1.4.1.23.2.1.1.18ScalaradminDownloadread-writemandatoryA write to adminDownload of temporaryChange(1) or permanentChange(2) causes the LANtern network monitor to discontinue its normal functions and perform a TFTP …
1.3.6.1.4.1.23.2.1.1.19ScalaradminResetwrite-onlymandatoryA write to adminReset causes the LANtern network monitor to discontinue its normal functions and commence a restart sequence. The contents of RAM, including al…
1.3.6.1.4.1.23.2.1.1.20ScalaradminSerialDataLinkread-writemandatoryThe type of data link encapsulation to be used on the serial line. adminSerialDataLink may be written at any time; however, the change does not take effect unt…
1.3.6.1.4.1.23.2.1.1.21ScalaradminSerialIPAddrread-writemandatoryThe IP address currently in use by the LANtern network monitor on the serial channel. adminSerialIPAddr may be written at any time; however, the change does no…
1.3.6.1.4.1.23.2.1.1.22ScalaradminSerialSubnetMaskread-writemandatoryThe subnet mask for the serial channel. adminSerialSubnetMask may be written at any time; however, the change does not take effect until the LANtern network mo…
1.3.6.1.4.1.23.2.1.1.23ScalaradminSerialBaudRateread-writemandatoryA codification of the baud rate to be used on the serial line for incoming calls or when the line is directly connected. Change does not switch line speed unti…
1.3.6.1.4.1.23.2.1.1.24ScalaradminSerialTimeoutread-writemandatoryOnce a phone connection has been established, the LANtern network monitor maintains that connection until either the other end hangs up or adminSerialTimeout s…
1.3.6.1.4.1.23.2.1.1.25ScalaradminSerialConnectionread-writemandatoryThe type of connection used by the serial line. adminSerialConnection may be written at any time; however, the change does not take effect until the LANtern ne…
1.3.6.1.4.1.23.2.1.1.26ScalaradminSerialFlowControlread-writemandatoryThe type of flow control used on the serial line. adminSerialFlowControl may be written at any time; however, the change does not take effect until the LANtern…
1.3.6.1.4.1.23.2.1.1.27ScalaradminModemControlread-writemandatoryA delimited string containing commands to initialize, dial, and hang up the modem. See Section 3.1.2 for more details on the format of this string. adminModemC…
1.3.6.1.4.1.23.2.1.1.28ScalaradminModemConnectread-writemandatoryA delimited string containing baud rates and modem responses when it connects at particular baud rates. See Section 3.1.2 for more details on the format of thi…
1.3.6.1.4.1.23.2.1.1.29ScalaradminModemNoConnectread-writemandatoryA delimited string containing baud rates and modem responses when it connects at particular baud rates. See Section 3 for more details on the format of this st…
1.3.6.1.4.1.23.2.1.1.30ScalaradminGatewayControlread-writemandatoryA switch to enable or disable IP gatewaying between the serial line and the network. See Section 3 for more details on the format of this string. adminGatewayC…
1.3.6.1.4.1.23.2.1.1.31TableadminPhoneTablenot-accessiblemandatoryA table that provides information about each possible phone connection that can be made over the serial channel. The table is accessed by adminPhoneIPAddr. A n…
1.3.6.1.4.1.23.2.1.1.31.1RowadminPhoneEntrynot-accessiblemandatoryData for a particular phone connection that can be established over the serial channel.
1.3.6.1.4.1.23.2.1.1.31.1.1ColumnadminPhoneIPAddrread-onlymandatoryThe IP address of the machine or IP network (SLIP gateway) at adminPhoneNumber.
1.3.6.1.4.1.23.2.1.1.31.1.2ColumnadminPhoneIPMaskread-writemandatoryThe IP subnet mask to be used when communicating over this phone connection. When the value 0.0.0.0 is stored in this variable, the LANtern network monitor ass…
1.3.6.1.4.1.23.2.1.1.31.1.3ColumnadminPhoneLocalIPAddrread-writemandatoryThe IP address the LANtern network monitor uses for its serial port while communicating over this phone connection.
1.3.6.1.4.1.23.2.1.1.31.1.4ColumnadminPhoneNumberread-writemandatoryThe phone number string the modem uses to dial the machine with IP address adminPhoneIPAddr.
1.3.6.1.4.1.23.2.1.1.31.1.5ColumnadminPhoneConnectionProtocolread-writemandatoryAn ASCII string specifying the logon sequence once the phone is connected.
1.3.6.1.4.1.23.2.1.1.31.1.6ColumnadminPhoneDeletewrite-onlymandatoryA write (any value) causes the table entry to be deleted.
1.3.6.1.4.1.23.2.1.1.32ScalaradminFCBControlread-writemandatoryA switch to disable the packet capture feature. To enable this flag (after disabling it) a cool start must apply to the LANtern in order to gain access into th…
Type Definitions
NameSyntaxStatusDescription
DisplayStringOCTET STRING
PhysAddressOCTET STRING
SecondsINTEGER
TimeINTEGER