MIB Viewer

OCCAM-MLT-MIB

116 objects
This mib module describes objects used to perform Metallic Line Testing on customer access lines and to provide results.
Imported Objects
OCCAM-REG-MODULEoccamGenericMonitorModules
SNMPv2-SMIInteger32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-IDENTITY OBJECT-TYPE
SNMPv2-TCTEXTUAL-CONVENTION
OIDNameAccessStatusDescription
1.3.6.1.4.1.6066.2.1.1.3IdentityoccamMltMibThis mib module describes objects used to perform Metallic Line Testing on customer access lines and to provide results.
1.3.6.1.4.1.6066.2.1.1.3.1NodemltTestConfig
1.3.6.1.4.1.6066.2.1.1.3.1.1ScalarmltTestIdentifierread-writecurrentSelects the mlt test to be run. Setting this value starts a test. This is a required parameter. Approximate expected test durations are as follows: statusSuite…
1.3.6.1.4.1.6066.2.1.1.3.1.2ScalarmltTestTyperead-writecurrentSelects if a test is requested (only run if port is not in use) or forced. This is an optional parameter. If not specified, the request option is used.
1.3.6.1.4.1.6066.2.1.1.3.1.3ScalarmltTestPortread-writecurrentSelects voice channel on which test will be run. This is a required parameter.
1.3.6.1.4.1.6066.2.1.1.3.1.4ScalarmltDcResistanceRangeread-writecurrentSelects DC Resistance range value. This is an optional paramater. Default is 0 (auto mode).
1.3.6.1.4.1.6066.2.1.1.3.1.5ScalarmltLoopLengthMultiplierread-writecurrentSelects loop length multiplier in nf. This is an optional parameter. If not specified an internal default value of 83nF/mile is used.
1.3.6.1.4.1.6066.2.1.1.3.1.6ScalarmltLoopDetectThresholdread-writecurrentSelects the detection threshold in nF. This is an optional parameter. If not supplied, a loop detection threshold of 10nF is used.
1.3.6.1.4.1.6066.2.1.1.3.2NodemltTestStatus
1.3.6.1.4.1.6066.2.1.1.3.2.1ScalarmltLastTestStatusread-onlycurrentIndicates the status of the last run mlt test. Given that the various mlt tests take several seconds to 1 1/2 minutes to run, it is suggested that status polls…
1.3.6.1.4.1.6066.2.1.1.3.2.2ScalarmltErrorTextread-onlycurrentIndicates the textual error in the case of an aborted test.
1.3.6.1.4.1.6066.2.1.1.3.3NodemltTestResults
1.3.6.1.4.1.6066.2.1.1.3.3.1TablemltStatusResultsTablenot-accessiblecurrentThis table provides result of the status test suite.
1.3.6.1.4.1.6066.2.1.1.3.3.1.1RowmltStatusResultsEntrynot-accessiblecurrentEntry holding information about results of status suite tests. Note that a numerical result value of -999 means that there was an error of some sort and the va…
1.3.6.1.4.1.6066.2.1.1.3.3.1.1.1ColumnmltStatusAlarmread-onlycurrentIndicates GNK and/or OTEMP alarms active when status test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.1.1.2ColumnmltStatusHookStateread-onlycurrentIndicates line hook state when status test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.1.1.3ColumnmltStatusTransversalCurrentread-onlycurrentIndicates transversal current when status test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.1.1.4ColumnmltStatusLongitudinalCurrentread-onlycurrentIndicates Longitudinal current when status test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.1.1.5ColumnmltStatusTipVoltageread-onlycurrentIndicates tip voltage when status test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.1.1.6ColumnmltStatusRingVoltageread-onlycurrentIndicates ring voltage when status test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.1.1.7ColumnmltStatusTipRingVoltageread-onlycurrentIndicates tip-ring voltage when status test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.1.1.8ColumnmltStatusVddread-onlycurrentIndicates Vdd when status test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.2TablemltTestResultsTablenot-accessiblecurrentThis table provides result of the mlt test suite. Note that a numerical result value of -999 means that there was an error of some sort and the value could not…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1RowmltTestResultsEntrynot-accessiblecurrentEntry holding information about results of mlt suite tests.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.1ColumnmltTestAlarmread-onlycurrentGNK and OTEMP bits set by the DuSLIC will be reported as alarms. GNK is typically cause by ground fault or foreign voltage condition. OTEMP is set when the DuS…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.2ColumnmltTestHookStateread-onlycurrentHook state reflects the DuSLIC hook bit (offhook/onhook). This parameter is non-intrusive.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.3ColumnmltTestVddread-onlycurrentOn HDPOTS, internal Voltage VDD will be reported and compared to statistically derived thresholds. This parameter is intrusive during offhook but will be avail…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.4ColumnmltTestActiveModeVoltagesVdctrread-onlycurrentActive Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be report…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.5ColumnmltTestActiveModeVoltagesVdctgread-onlycurrentActive Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be report…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.6ColumnmltTestActiveModeVoltagesVdcrgread-onlycurrentActive Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be report…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.7ColumnmltTestActiveModeVoltagesVactrread-onlycurrentActive Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. …
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.8ColumnmltTestActiveModeVoltagesVactgread-onlycurrentActive Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. …
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.9ColumnmltTestActiveModeVoltagesVacrgread-onlycurrentActive Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. …
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.10ColumnmltTestHighImpedanceModeVoltagesVdctrread-onlycurrentHigh Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent forei…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.11ColumnmltTestHighImpedanceModeVoltagesVdctgread-onlycurrentHigh Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent forei…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.12ColumnmltTestHighImpedanceModeVoltagesVdcrgread-onlycurrentHigh Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent forei…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.13ColumnmltTestHighImpedanceModeVoltagesVactrread-onlycurrentHigh Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent forei…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.14ColumnmltTestHighImpedanceModeVoltagesVactgread-onlycurrentHigh Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent forei…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.15ColumnmltTestHighImpedanceModeVoltagesVacrgread-onlycurrentHigh Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent forei…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.16ColumnmltTestDcCurrentsItransversalread-onlycurrentFour DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available i…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.17ColumnmltTestDcCurrentsIlongitudinalread-onlycurrentFour DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available i…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.18ColumnmltTestDcCurrentsItipread-onlycurrentFour DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available i…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.19ColumnmltTestDcCurrentsIringread-onlycurrentFour DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available i…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.20ColumnmltTestCapacitanceCeqtrread-onlycurrentCapacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacita…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.21ColumnmltTestCapacitanceCeqtgread-onlycurrentCapacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacita…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.22ColumnmltTestCapacitanceCeqrgread-onlycurrentCapacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacita…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.23ColumnmltTestResistanceRtrread-onlycurrentDC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.24ColumnmltTestResistanceRtgread-onlycurrentDC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.25ColumnmltTestResistanceRrgread-onlycurrentDC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.26ColumnmltTestGr909HazardousPotentialTestResultread-onlycurrentThis test fails if the T-G or R-G ac voltage is greater than 50 volts rms or the T-G or R-G dc voltage is greater than 135 volts. This test will report pass/fa…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.27ColumnmltTestGr909ForeignEmfTestResultread-onlycurrentThis test fails if the T-G or R-G ac voltage is greater than 50 volts rms or the T-G or R-G dc voltage is greater than 135 volts. This test will report pass/fa…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.28ColumnmltTestGr909FuseTestTipFuseread-onlyobsoleteThis test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This para…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.29ColumnmltTestGr909FuseTestRingFuseread-onlyobsoleteThis test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This para…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.30ColumnmltTestGr909ResistiveFaultTestResultread-onlycurrentThis test fails if the T-R, T-G or R-G dc resistance is less than 150k ohm. This test will not be performed if fuse test fails or alarm is present. This test w…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.31ColumnmltTestGr909ReceiverOffhookTestResultread-onlycurrentThis test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be per…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.32ColumnmltTestGr909ReceiverOffhookTestResistance1read-onlycurrentThis test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be per…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.33ColumnmltTestGr909ReceiverOffhookTestResistance2read-onlycurrentThis test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be per…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.34ColumnmltTestGr909ReceiverOffhookTestDifferenceread-onlycurrentThis test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be per…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.35ColumnmltTestGr909RingerTestResultread-onlycurrentThis test fails when the equivalent ringer count across tip and ring is less than 0.175 REN or greater than 5 REN. This test will not run if fuse test fails or…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.36ColumnmltTestGr909RingerTestRenread-onlycurrentThis test fails when the equivalent ringer count across tip and ring is less than 0.175 REN or greater than 5 REN. This test will not run if fuse test fails or…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.37ColumnmltTestErrorsread-onlycurrentIndicates GNK and/or OTEMP alarms active when test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.38ColumnmltTestFuseTestTipFuseread-onlycurrentThis test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This para…
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.39ColumnmltTestFuseTestRingFuseread-onlycurrentThis test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This para…
1.3.6.1.4.1.6066.2.1.1.3.3.3TablemltActiveModeVoltagesResultsTablenot-accessiblecurrentThis table provides results of the mlt active mode voltages test. Note that a numerical result value of -999 means that there was an error of some sort and the…
1.3.6.1.4.1.6066.2.1.1.3.3.3.1RowmltActiveModeVoltagesResultsEntrynot-accessiblecurrentEntry holding information about results of mlt active mode voltages test.
1.3.6.1.4.1.6066.2.1.1.3.3.3.1.1ColumnmltActiveModeVoltagesVdctrread-onlycurrentActive Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be report…
1.3.6.1.4.1.6066.2.1.1.3.3.3.1.2ColumnmltActiveModeVoltagesVdctgread-onlycurrentActive Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be report…
1.3.6.1.4.1.6066.2.1.1.3.3.3.1.3ColumnmltActiveModeVoltagesVdcrgread-onlycurrentActive Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be report…
1.3.6.1.4.1.6066.2.1.1.3.3.3.1.4ColumnmltActiveModeVoltagesVactrread-onlycurrentActive Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. …
1.3.6.1.4.1.6066.2.1.1.3.3.3.1.5ColumnmltActiveModeVoltagesVactgread-onlycurrentActive Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. …
1.3.6.1.4.1.6066.2.1.1.3.3.3.1.6ColumnmltActiveModeVoltagesVacrgread-onlycurrentActive Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. …
1.3.6.1.4.1.6066.2.1.1.3.3.3.1.7ColumnmltActiveModeVoltagesErrorsread-onlycurrentIndicates GNK and/or OTEMP alarms active when test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.4TablemltHighImpedanceModeVoltagesResultsTablenot-accessiblecurrentThis table provides result of the mlt test suite. Note that a numerical result value of -999 means that there was an error of some sort and the value could not…
1.3.6.1.4.1.6066.2.1.1.3.3.4.1RowmltHighImpedanceModeVoltagesResultsEntrynot-accessiblecurrentEntry holding information about results of mlt high impedance mode voltages test.
1.3.6.1.4.1.6066.2.1.1.3.3.4.1.1ColumnmltHighImpedanceModeVoltagesVdctrread-onlycurrentHigh Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent forei…
1.3.6.1.4.1.6066.2.1.1.3.3.4.1.2ColumnmltHighImpedanceModeVoltagesVdctgread-onlycurrentHigh Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent forei…
1.3.6.1.4.1.6066.2.1.1.3.3.4.1.3ColumnmltHighImpedanceModeVoltagesVdcrgread-onlycurrentHigh Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent forei…
1.3.6.1.4.1.6066.2.1.1.3.3.4.1.4ColumnmltHighImpedanceModeVoltagesVactrread-onlycurrentHigh Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent forei…
1.3.6.1.4.1.6066.2.1.1.3.3.4.1.5ColumnmltHighImpedanceModeVoltagesVactgread-onlycurrentHigh Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent forei…
1.3.6.1.4.1.6066.2.1.1.3.3.4.1.6ColumnmltHighImpedanceModeVoltagesVacrgread-onlycurrentHigh Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent forei…
1.3.6.1.4.1.6066.2.1.1.3.3.4.1.7ColumnmltHighImpedanceModeVoltagesErrorsread-onlycurrentIndicates GNK and/or OTEMP alarms active when test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.5TablemltDcResistanceResultsTablenot-accessiblecurrentThis table provides result of the DC resistance test. Note that a numerical result value of -999 means that there was an error of some sort and the value could…
1.3.6.1.4.1.6066.2.1.1.3.3.5.1RowmltDcResistanceResultsEntrynot-accessiblecurrentEntry holding information about results of mlt DC resistance test.
1.3.6.1.4.1.6066.2.1.1.3.3.5.1.1ColumnmltDcResistanceRtrread-onlycurrentDC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance…
1.3.6.1.4.1.6066.2.1.1.3.3.5.1.2ColumnmltDcResistanceRtgread-onlycurrentDC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance…
1.3.6.1.4.1.6066.2.1.1.3.3.5.1.3ColumnmltDcResistanceRrgread-onlycurrentDC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance…
1.3.6.1.4.1.6066.2.1.1.3.3.5.1.4ColumnmltDcResistanceErrorsread-onlycurrentIndicates GNK and/or OTEMP alarms active when test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.6TablemltCapacitanceResultsTablenot-accessiblecurrentThis table provides result of the mlt test suite. Note that a numerical result value of -999 means that there was an error of some sort and the value could not…
1.3.6.1.4.1.6066.2.1.1.3.3.6.1RowmltCapacitanceResultsEntrynot-accessiblecurrentEntry holding information about results of mlt capacitance test.
1.3.6.1.4.1.6066.2.1.1.3.3.6.1.1ColumnmltCapacitanceCeqtrread-onlycurrentCapacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacita…
1.3.6.1.4.1.6066.2.1.1.3.3.6.1.2ColumnmltCapacitanceCeqtgread-onlycurrentCapacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacita…
1.3.6.1.4.1.6066.2.1.1.3.3.6.1.3ColumnmltCapacitanceCeqrgread-onlycurrentCapacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacita…
1.3.6.1.4.1.6066.2.1.1.3.3.6.1.4ColumnmltCapacitanceErrorsread-onlycurrentIndicates GNK and/or OTEMP alarms active when test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.7TablemltLoopDetectResultsTablenot-accessiblecurrentThis table provides result of the mlt loop detect test. Note that a numerical result value of -999 means that there was an error of some sort and the value cou…
1.3.6.1.4.1.6066.2.1.1.3.3.7.1RowmltLoopDetectResultsEntrynot-accessiblecurrentEntry holding information about results of mlt loop detect test.
1.3.6.1.4.1.6066.2.1.1.3.3.7.1.1ColumnmltLoopDetectLoopCapacitanceread-onlycurrentLoop detection will be based on tip-ring capacitance measurement. User will be able to specify the detection threshold. If not supplied,loop detection threshol…
1.3.6.1.4.1.6066.2.1.1.3.3.7.1.2ColumnmltLoopDetectDetectionThresholdread-onlycurrentLoop detection will be based on tip-ring capacitance measurement. User will be able to specify the detection threshold. If not supplied, loop detection thresho…
1.3.6.1.4.1.6066.2.1.1.3.3.7.1.3ColumnmltLoopDetectLoopDetectedread-onlycurrentLoop detection will be based on tip-ring capacitance measurement. User will be able to specify the detection threshold. If not supplied, loop detection thresho…
1.3.6.1.4.1.6066.2.1.1.3.3.7.1.4ColumnmltLoopDetectErrorsread-onlycurrentIndicates GNK and/or OTEMP alarms active when test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.8TablemltLoopLengthResultsTablenot-accessiblecurrentThis table provides result of the mlt loop length test. Note that a numerical result value of -999 means that there was an error of some sort and the value cou…
1.3.6.1.4.1.6066.2.1.1.3.3.8.1RowmltLoopLengthResultsEntrynot-accessiblecurrentEntry holding information about results of mlt loop length test.
1.3.6.1.4.1.6066.2.1.1.3.3.8.1.1ColumnmltLoopLengthCapacitanceFactorread-onlycurrentLoop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length m…
1.3.6.1.4.1.6066.2.1.1.3.3.8.1.2ColumnmltLoopLengthLoopCapacitanceread-onlycurrentLoop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length m…
1.3.6.1.4.1.6066.2.1.1.3.3.8.1.3ColumnmltLoopLengthLoopLengthread-onlycurrentLoop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length m…
1.3.6.1.4.1.6066.2.1.1.3.3.8.1.4ColumnmltLoopLengthUncompensatedLoopCapacitanceread-onlycurrentLoop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length m…
1.3.6.1.4.1.6066.2.1.1.3.3.8.1.5ColumnmltLoopLengthUncompensatedLoopLengthread-onlycurrentLoop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length m…
1.3.6.1.4.1.6066.2.1.1.3.3.8.1.6ColumnmltLoopLengthErrorsread-onlycurrentIndicates GNK and/or OTEMP alarms active when test was run.
1.3.6.1.4.1.6066.2.1.1.3.4NodemltTestNotifications
1.3.6.1.4.1.6066.2.1.1.3.4.1NotificationmltTestCompletedNotificationcurrentThis notification is sent to the requesting host when the requested mlt test has completed.
Type Definitions
NameSyntaxStatusDescription
MltTestHookStateINTEGER { onhook ( 1 ) , offhook ( 2 ), notAvailable ( 3 ) }currentAn mlt test hook state value.
MltTestIdentifierINTEGER { statusSuite ( 1 ) , mltSuite ( 2 ) , activeModeVoltages ( 3 ) , highImpedanceModeVoltages ( 4 ) , dcResistance ( 5 ) , capacitance ( 6 ) , loopDetect ( 7 ) , loopLength ( 8 ) }currentAn mlt test selection value.
MltTestPassFailINTEGER { pass ( 1 ) , fail ( 2 ), notAvailable ( 3 ) }currentAn mlt test pass/fail value.
MltTestRingerResultINTEGER { pass ( 1 ) , fail ( 2 ), notAvailable ( 3 ), low ( 4 ) }currentAn mlt ringer test result value.
MltTestStatusINTEGER { none ( 1 ) , mltBusy ( 2 ), complete ( 3 ) , portInUse ( 4 ) , inProgress ( 5 ), mltError ( 6 ), mltNotResponding ( 7 ) }currentAn indication of test status: none = no test has been requested. mltbusy = another port is currently being tested. complete = the last requested test has completed. portInUse = the last requested port is in use, the tes…
MltTestTypeINTEGER { request ( 1 ) , force ( 2 ) }currentA selection value for requesting or forcing a test. A requested test will only run if the port is not in use. A forced test will immediately shut the port and run the test.
MltTestYesNoINTEGER { yes ( 1 ) , no ( 2 ), notAvailable ( 3 ) }currentAn mlt test pass/fail value.