ODS-FDDIMIB
21 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1155-SMI MISSING | Counter enterprises Gauge IpAddress NetworkAddress TimeTicks |
| RFC-1158 MISSING | snmp |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.50 | Nodeods | |||
| 1.3.6.1.4.1.50.1 | Nodeenc | |||
| 1.3.6.1.4.1.50.2 | NodeenBridge | |||
| 1.3.6.1.4.1.50.3 | NodetokenRing | |||
| 1.3.6.1.4.1.50.4 | NodetrBridge | |||
| 1.3.6.1.4.1.50.5 | Nodefddi | |||
| 1.3.6.1.4.1.50.5.1 | ScalarfddiChassisId | read-only | mandatory | The type of chassis used for the concentrator. For modular concentrators, the hardware is further qualifed by the value of fddiCardId for each card installed i… |
| 1.3.6.1.4.1.50.5.2 | ScalarfddiChassisDescr | read-only | mandatory | A textual description of the concentrator chassis being used. |
| 1.3.6.1.4.1.50.5.3 | ScalarfddiPowerSupplyMap | read-only | mandatory | Specifies the location of the power supply(s) in the chassis. Bit 0 represents the left power supply and bit 1 represents the right. If the bit is set then the… |
| 1.3.6.1.4.1.50.5.4 | ScalarfddiPowerSupplyStatus | read-only | mandatory | Specifies the status of the power supply(s) in the chassis. Bit 0 represent the left power supply status an bit 1 represents the right. If the bit is set then … |
| 1.3.6.1.4.1.50.5.5 | ScalarfddiCardCapacity | read-only | mandatory | The number of card slots that is contained in the concentrator chassis. |
| 1.3.6.1.4.1.50.5.6 | ScalarfddiCardNumber | read-only | mandatory | The number of cards that are currently installed in the concentrator chassis. |
| 1.3.6.1.4.1.50.5.7 | TablefddiCardTable | not-accessible | mandatory | A list of card entries for each card installed in the concentrator. The number of entries is given by the value of fddiCardNumber. |
| 1.3.6.1.4.1.50.5.7.1 | RowfddiCardEntry | not-accessible | mandatory | A card entry containing objects pertaining to a card installed in the concentrator. |
| 1.3.6.1.4.1.50.5.7.1.1 | ColumnfddiCardIndex | read-only | mandatory | The slot in which the card is installed. This value uniquely identifies the card. Its value ranges between 1 and the value of fddiCardCapacity. |
| 1.3.6.1.4.1.50.5.7.1.2 | ColumnfddiCardId | read-only | mandatory | The type of card installed in the concentrator. |
| 1.3.6.1.4.1.50.5.7.1.3 | ColumnfddiCardDescr | read-only | mandatory | A textual description of the card including the ODS model number, media type and number of ports. |
| 1.3.6.1.4.1.50.5.7.1.4 | ColumnfddiCardStatus | read-only | mandatory | This value indicated whether the card is on-line or off-line. |
| 1.3.6.1.4.1.50.5.7.1.5 | ColumnfddiCardPortNumber | read-only | mandatory | This value specifies the number of ports contained on the card. |
| 1.3.6.1.4.1.50.5.7.1.6 | ColumnfddiCardPortIndex | read-only | mandatory | This value is the SMT index of the first port on this card. |
| 1.3.6.1.4.1.50.5.7.1.7 | ColumnfddiCardBypassStatus | read-only | mandatory | This value specifies the status of the optical bypass for this card. |