MIB Viewer

ODS-TRMIB

83 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1155-SMI MISSINGCounter enterprises Gauge IpAddress NetworkAddress TimeTicks
RFC-1158 MISSINGsnmp
OIDNameAccessStatusDescription
1.3.6.1.4.1.50Nodeods
1.3.6.1.4.1.50.1Nodeenc
1.3.6.1.4.1.50.1.1NodeloopBackTrapThe LoopBack state of a RingIn or RingOut port has changed. The changedValue indicates the current LoopBack state. This trap will only be sent if the value of …
1.3.6.1.4.1.50.1.2NoderingInsertTrapThe RingInsertion state of a user port has changed. The changedValue indicates the current RingInsertion state. This trap will only be sent if the value of teR…
1.3.6.1.4.1.50.1.3NodedeinCountTrapThe DeinCount value for a user port has incremented above 1. The changedValue indicates the current value for DeinCount. This trap will only be sent if the val…
1.3.6.1.4.1.50.1.4NodeportDisabledTrapThe PortEnable for a user port has been automatically disabled due to an excessive number of consecutive deinsertions. (Excessive is defined by boxMaxDeinCount…
1.3.6.1.4.1.50.1.5NodeswitchChangeTrapA Switch has changed on the front panel of the box. The changedOid defines the variable that has has changed. The changedValue indicates the current value for …
1.3.6.1.4.1.50.2NodeenBridge
1.3.6.1.4.1.50.3NodetokenRing
1.3.6.1.4.1.50.3.1NodetrMib1
1.3.6.1.4.1.50.3.1.1NodetrSystem
1.3.6.1.4.1.50.3.1.1.1NodetrBox
1.3.6.1.4.1.50.3.1.1.1.1ScalarboxChassisIdread-onlymandatoryThe type of chassis used for the concentrator. For modular concentrators, the hardware is further qualifed by the value of cardId for each card installed in th…
1.3.6.1.4.1.50.3.1.1.1.4ScalarboxMaxDeinCountread-writemandatoryContains the maximum number of successive de-inserts that can occur before a given port is shut off automatically.
1.3.6.1.4.1.50.3.1.1.1.5ScalarboxMaxDeinDeltaread-writemandatoryThe maximum time in seconds between successive de-inserts for a given port for which the portDeinCount will be incremeneted.
1.3.6.1.4.1.50.3.1.1.1.7ScalarboxResetread-writemandatorySetting to 1 will reboot the agent.
1.3.6.1.4.1.50.3.1.1.1.8ScalarboxFWVersionread-onlymandatoryThe version of the firmware that is currently resident.
1.3.6.1.4.1.50.3.1.1.1.9ScalartrapIdnot-accessiblemandatoryThe trap Id for this particular trap. It is a one-up counter that identifies this trap.
1.3.6.1.4.1.50.3.1.1.1.10ScalarchangedOidnot-accessiblemandatoryThe Object Id of the variable that is the reason for sending the trap.
1.3.6.1.4.1.50.3.1.1.1.11ScalarchangedValuenot-accessiblemandatoryThe value of the variable that is being trapped.
1.3.6.1.4.1.50.3.1.1.1.12ScalarchangedDescrnot-accessiblemandatoryA textual description of the variable, the slot, the port, and the new value that is being trapped.
1.3.6.1.4.1.50.3.1.1.1.13ScalartftpAddressread-writemandatoryThe IP address from which TFTP packets will be accepted by the agent.
1.3.6.1.4.1.50.3.1.1.1.14ScalardosCommandread-writemandatoryA Dos command that will be executed.
1.3.6.1.4.1.50.3.1.1.1.15ScalardosExitCoderead-onlymandatoryThe status of the last executed DOS command.
1.3.6.1.4.1.50.3.1.1.2NodetrCards
1.3.6.1.4.1.50.3.1.1.2.1ScalarcardNumSlotsread-onlymandatoryThe number of slots in the concentrator. For modular concentrators, this value is the maximum number of cards that can be installed. For non-modular concentrat…
1.3.6.1.4.1.50.3.1.1.2.2ScalarcardNumCardsread-onlymandatoryThe number of cards actually installed in the concentrator. For non-modular concentrators, the value is always one.
1.3.6.1.4.1.50.3.1.1.2.3TablecardTablenot-accessiblemandatoryA list of card entries for each card installed in the concentrator. The number of entries is given by the value of CardNumCards.
1.3.6.1.4.1.50.3.1.1.2.3.1RowcardEntrynot-accessiblemandatoryA card entry containing objects pertaining to a card installed in the concentrator.
1.3.6.1.4.1.50.3.1.1.2.3.1.1ColumncardBypassread-writemandatoryThe current bypass state of the card.
1.3.6.1.4.1.50.3.1.1.2.3.1.2ColumncardRingStarread-writemandatoryThe Ring/Star mode of the card.
1.3.6.1.4.1.50.3.1.1.2.3.1.3ColumncardRingSpeedread-onlymandatoryThe Ring Speed of the card.
1.3.6.1.4.1.50.3.1.1.2.3.1.4ColumncardCableTyperead-writemandatoryThe card's Cable Type.
1.3.6.1.4.1.50.3.1.1.2.3.1.6ColumncardResetread-onlymandatoryThe card's Reset Switch state.
1.3.6.1.4.1.50.3.1.1.2.3.1.7ColumncardSwitchread-onlymandatoryThe state of the HW/SW switch on the card.
1.3.6.1.4.1.50.3.1.1.2.3.1.8ColumncardControlread-onlymandatoryWho currently controls the card, HW or SW.
1.3.6.1.4.1.50.3.1.1.2.3.1.9ColumncardIdread-onlymandatoryThe type of card installed in the concentrator.
1.3.6.1.4.1.50.3.1.1.2.3.1.10ColumncardIndexread-onlymandatoryThe slot in which the card is installed. This value uniquely identifies the card. Its value ranges between 1 and the value of CardNumSlots.
1.3.6.1.4.1.50.3.1.1.2.3.1.11ColumncardDescripread-onlymandatoryA textual description of the card including the ODS model number, media type and number of ports.
1.3.6.1.4.1.50.3.1.1.2.3.1.12ColumncardNumPortsread-onlymandatoryThe number of configurable ports on the card. For some cards, the value may be zero.
1.3.6.1.4.1.50.3.1.1.2.3.1.13ColumncardHasPortsread-onlymandatoryThis value describes if there are configurable user ports on the card.
1.3.6.1.4.1.50.3.1.1.2.3.1.14ColumncardHasRingIntread-onlymandatoryThis value describes if the card has ring in and ring out ports.
1.3.6.1.4.1.50.3.1.1.2.3.1.15ColumncardHasTWread-onlymandatoryThis value describes if the card's user ports are twisted wire or not.
1.3.6.1.4.1.50.3.1.1.3NodetrPorts
1.3.6.1.4.1.50.3.1.1.3.1TableportTablenot-accessiblemandatoryA list of port entries for each interface port in the concentrator. The number of entries is given by the sum of CardNumPorts for each card in the CardTable.
1.3.6.1.4.1.50.3.1.1.3.1.1RowportEntrynot-accessiblemandatoryA port entry containing objects pertaining to an interface port in the concentrator.
1.3.6.1.4.1.50.3.1.1.3.1.1.1ColumnportEnableread-writemandatoryThe current enable status of the port. If the value is off(2), no data is passed through the port.
1.3.6.1.4.1.50.3.1.1.3.1.1.2ColumnportActStatusread-onlymandatoryWhether we currently see activity on the port. If we have activity, then the value is true(1).
1.3.6.1.4.1.50.3.1.1.3.1.1.3ColumnportRingInsertread-onlymandatoryWhether someone is currently inserted onto the ring through this port. If true(1), then someone is inserted onto this port.
1.3.6.1.4.1.50.3.1.1.3.1.1.4ColumnportDeinCountread-writemandatoryCurrent count of successive deinserts that occurred on this port, each within MaxDeinDelta of the previous deinsert.
1.3.6.1.4.1.50.3.1.1.3.1.1.5ColumnportCardread-onlymandatoryThe card on which the port exists. The card identified by this value is the same card as identified by the same value of CardIndex.
1.3.6.1.4.1.50.3.1.1.3.1.1.6ColumnportIndexread-onlymandatoryAn integer which uniquely identifes this port on the card. Its value ranges between 1 and the value of CardNumPorts for the card.
1.3.6.1.4.1.50.3.1.1.4NodetrRing
1.3.6.1.4.1.50.3.1.1.4.1TableringportTablenot-accessiblemandatoryA list of entries for Ring In and Ring Out ports of the concentrator.
1.3.6.1.4.1.50.3.1.1.4.1.1RowringEntrynot-accessiblemandatoryA ring port entry containing objects pertaining the concentrator's Ring In and Ring Out ports.
1.3.6.1.4.1.50.3.1.1.4.1.1.1ColumnrpModeread-writemandatoryThe current status of the ring port.
1.3.6.1.4.1.50.3.1.1.4.1.1.2ColumnrpFOTWread-writemandatoryWhether fiber optic or twisted wire are currently being used by the ring port.
1.3.6.1.4.1.50.3.1.1.4.1.1.3ColumnrpLoopBackread-onlymandatoryWhether the concentrator's ring port is in loopback mode.
1.3.6.1.4.1.50.3.1.1.4.1.1.4ColumnrpVoltSenseread-onlymandatoryWhether voltage is being sensed across the ring port.
1.3.6.1.4.1.50.3.1.1.4.1.1.5ColumnrpActStatusread-onlymandatoryWhether we currently see activity on the port. if we have activity, then the value is true(1).
1.3.6.1.4.1.50.3.1.1.4.1.1.6ColumnrpCarrSenseread-onlymandatoryWhether a carrier is sensed on the ring port.
1.3.6.1.4.1.50.3.1.1.4.1.1.7ColumnrpCardread-onlymandatoryThe card on which the ring ports exist. The card identified by this value is the same card as identified by the same value of CardIndex.
1.3.6.1.4.1.50.3.1.1.4.1.1.8ColumnrpIndexread-onlymandatoryAn integer which uniquely identifies this ring port on the card. Its value ranges between 1 (Ring In) and 2 (Ring Out).
1.3.6.1.4.1.50.3.1.1.4.1.1.9ColumnrpHasTWread-onlymandatoryWhether or not the ring port has Twisted Wire.
1.3.6.1.4.1.50.3.1.1.5NodetrTrapEnable
1.3.6.1.4.1.50.3.1.1.5.1ScalarteLoopBackread-writemandatoryThe Loopback state for a ring port has changed. This trap will be sent to the defined management station(s) if the value of teLoopBack enabled(1).
1.3.6.1.4.1.50.3.1.1.5.2ScalarteModeread-writemandatoryThe state of the Ring Port mode switch has changed (Normal, Internal Loop, Auto Loop). This trap will be sent to the defined management station(s) if the value…
1.3.6.1.4.1.50.3.1.1.5.3ScalarteFOTWread-writemandatoryThe state of the Fiber Optic/Twisted Wire switch has changed. This trap will be sent to the defined management station(s) if the value of teFOTW is enabled(1).
1.3.6.1.4.1.50.3.1.1.5.4ScalarteRingInsertread-writemandatoryA user was inserted onto the ring or de-inserted from the ring. This trap will be sent to the defined management station(s) if the value of teRingInsert is ena…
1.3.6.1.4.1.50.3.1.1.5.5ScalarteDeinCountread-writemandatoryThe De-insert count for one of the user ports is now greater than 1. This trap will be sent to the defined management station(s) if the value of teDeinCount is…
1.3.6.1.4.1.50.3.1.1.5.6ScalarteEnableread-writemandatoryThe state of one of the user port switches has changed. This trap will be sent to the defined management station(s) if the value of teEnable is enabled(1).
1.3.6.1.4.1.50.3.1.1.5.7ScalarteBypassread-writemandatoryThe state of the Bypass control switch has changed. This trap will be sent to the defined management station(s) if the value of teBypass is enabled(1).
1.3.6.1.4.1.50.3.1.1.5.8ScalarteRingStarread-writemandatoryThe state of the Ring/Star control switch has changed. This trap will be sent to the defined management station(s) if the value of teRingStar is enabled(1).
1.3.6.1.4.1.50.3.1.1.5.9ScalarteRingSpeedread-writemandatoryThe state of the Ring Speed (Clock) control switch has changed. This trap will be sent to the defined management station(s) if the value of te_4_16 is enabled(…
1.3.6.1.4.1.50.3.1.1.5.10ScalarteCableTyperead-writemandatoryThe state of the Cable Type control switch has changed. This trap will be sent to the defined management station(s) if the value of teCableType is enabled(1).
1.3.6.1.4.1.50.3.1.1.5.12ScalarteSwitchread-writemandatoryThe state of the HW/SW control switch has changed. This trap will be sent to the defined management station(s) if the value of teSwitch is enabled(1).
1.3.6.1.4.1.50.3.1.1.5.15ScalarteLanManagerread-writemandatoryThe Ringin or Ringout has gone into Loopback. This alert will be sent to IBM's Lan Manager management station(s) if the value of teLanManager is enabled(1).
1.3.6.1.4.1.50.3.1.2NodetrAdmin
1.3.6.1.4.1.50.4NodetrBridge
1.3.6.1.4.1.10297.202.7000.7.2.0NodecoldStartTrapThe agent has re-initialized and may need to be reconfigured. This trap will be sent to each management station defined in the communty.cfg file.
1.3.6.1.4.1.10297.202.7000.7.2.4NodeauthFailTrapAn SNMP request was received that did not have a valid community name or a write was attempted on a read-only variable. This trap will be sent to each manageme…
Type Definitions
NameSyntaxStatusDescription
DisplayStringOCTET STRING
PhysAddressOCTET STRING