OMNI-gx2Dm200-MIB
167 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.19.1 | Nodegx2Dm200Descriptor | |||
| 1.3.6.1.4.1.1166.6.1.2.19.1 | NodetrapDM200ConfigChangeInteger | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre… | ||
| 1.3.6.1.4.1.1166.6.1.2.19.2 | Tablegx2Dm200AnalogTable | not-accessible | mandatory | This table contains gx2Dm200 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.19.2 | NodetrapDM200ConfigChangeDisplayString | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may … | ||
| 1.3.6.1.4.1.1166.6.1.2.19.2.1 | Rowgx2Dm200AnalogEntry | not-accessible | mandatory | This list contains the analog parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.1 | Columngx2Dm200AnalogTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.2 | Columndm200labelOffsetNomMonitor | read-only | optional | The value of this object provides the label of the Offset Monitor Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.3 | Columndm200uomOffsetNomMonitor | read-only | optional | The value of this object provides the Unit of Measure of the Offset Monitor Analog parameter. The unit of measure for this parameter is dB |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.4 | Columndm200majorHighOffsetNomMonitor | read-only | obsolete | The value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This object is not used by this module and always returns … |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.5 | Columndm200majorLowOffsetNomMonitor | read-only | obsolete | The value of this object provides the Major Low alarm value of the Offset Monitor Power Analog parameter. This object is not used by this module and always ret… |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.6 | Columndm200minorHighOffsetNomMonitor | read-only | obsolete | The value of this object provides the Minor High alarm value of the Offset Monitor Power Analog parameter. This object is not used by this module and always re… |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.7 | Columndm200minorLowOffsetNomMonitor | read-only | obsolete | The value of this object provides the Minor Low alarm value of the Offset Monitor Power Analog parameter. This object is not used by this module and always ret… |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.8 | Columndm200currentValueOffsetNomMonitor | read-only | mandatory | The value of this object provides the Current value of the Offset Monitor Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.9 | Columndm200stateFlagOffsetNomMonitor | read-only | mandatory | The value of this object provides the state of the Offset Monitor Power Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.10 | Columndm200minValueOffsetNomMonitor | read-only | mandatory | The value of this object provides the minimum value the Offset Monitor Power Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.11 | Columndm200maxValueOffsetNomMonitor | read-only | mandatory | The value of this object provides the maximum value the Offset Monitor Power Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.12 | Columndm200alarmStateOffsetNomMonitor | read-only | mandatory | The value of this object provides the curent alarm state of the Offset Monitor Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.13 | Columndm200labelAttenSetting | read-only | optional | The value of this object provides the label of the Attenuator Setting Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.14 | Columndm200uomAttenSetting | read-only | optional | The value of this object provides the Unit of Measure of the Attenuator Setting Analog parameter. The unit of measure for this parameter is dB |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.15 | Columndm200majorHighAttenSetting | read-only | obsolete | The value of this object provides the Major High alarm value of the Attenuator Setting Analog parameter. This object is not used by this module and always retu… |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.16 | Columndm200majorLowAttenSetting | read-only | obsolete | The value of this object provides the Major Low alarm value of the Attenuator Setting Analog parameter. This object is not used by this module and always retur… |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.17 | Columndm200minorHighAttenSetting | read-only | obsolete | The value of this object provides the Minor High alarm value of the Attenuator Setting Analog parameter. This object is not used by this module and always retu… |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.18 | Columndm200minorLowAttenSetting | read-only | obsolete | The value of this object provides the Minor Low alarm value of the Attenuator Setting Analog parameter. This object is not used by this module and always retur… |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.19 | Columndm200currentValueAttenSetting | read-write | mandatory | The value of this object provides the Current value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.20 | Columndm200stateFlagAttenSetting | read-only | mandatory | The value of this object provides the state of the Attenuator Setting Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.21 | Columndm200minValueAttenSetting | read-only | mandatory | The value of this object provides the minimum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.22 | Columndm200maxValueAttenSetting | read-only | mandatory | The value of this object provides the maximum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.23 | Columndm200alarmStateAttenSetting | read-only | mandatory | The value of this object provides the curent alarm state of the Attenuator Setting Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.24 | Columndm200labelLaserPower | read-only | optional | The value of this object provides the label of the Laser Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.25 | Columndm200uomLaserPower | read-only | optional | The value of this object provides the Unit of Measure of the Laser Optical Power Analog parameter. The unit of measure for this parameter is dBm |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.26 | Columndm200majorHighLaserPower | read-only | mandatory | The value of this object provides the Major High alarm value of the Laser Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.27 | Columndm200majorLowLaserPower | read-only | mandatory | The value of this object provides the Major Low alarm value of the Laser Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.28 | Columndm200minorHighLaserPower | read-only | obsolete | The value of this object provides the Minor High alarm value of the Laser Optical Power Analog parameter. This object is not used by this module and always ret… |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.29 | Columndm200minorLowLaserPower | read-only | obsolete | The value of this object provides the Minor Low alarm value of the Laser Optical Power Analog parameter. This object is not used by this module and always retu… |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.30 | Columndm200currentValueLaserPower | read-only | mandatory | The value of this object provides the Current value of the Laser Optical Power Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.31 | Columndm200stateFlagLaserPower | read-only | mandatory | The value of this object provides the state of the Laser Optical Power Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.32 | Columndm200minValueLaserPower | read-only | mandatory | The value of this object provides the minimum value the Laser Optical Power Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.33 | Columndm200maxValueLaserPower | read-only | mandatory | The value of this object provides the maximum value the Laser Optical Power Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.34 | Columndm200alarmStateLaserPower | read-only | mandatory | The value of this object provides the curent alarm state of the Laser Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.35 | Columndm200labelLaserTemp | read-only | optional | The value of this object provides the label of the Laser Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.36 | Columndm200uomLaserTemp | read-only | optional | The value of this object provides the Unit of Measure of the Laser Temperature Analog parameter. The unit of measure for this parameter is degrees C |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.37 | Columndm200majorHighLaserTemp | read-only | mandatory | The value of this object provides the Major High alarm value of the Laser Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.38 | Columndm200majorLowLaserTemp | read-only | mandatory | The value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.39 | Columndm200minorHighLaserTemp | read-only | obsolete | The value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.40 | Columndm200minorLowLaserTemp | read-only | obsolete | The value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.41 | Columndm200currentValueLaserTemp | read-only | mandatory | The value of this object provides the Current value of the Laser Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.42 | Columndm200stateFlagLaserTemp | read-only | mandatory | The value of this object provides the state of the Laser Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.43 | Columndm200minValueLaserTemp | read-only | mandatory | The value of this object provides the minimum value the Laser Temperature Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.44 | Columndm200maxValueLaserTemp | read-only | mandatory | The value of this object provides the maximum value the Laser Temperature Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.45 | Columndm200alarmStateLaserTemp | read-only | mandatory | The value of this object provides the curent alarm state of the Laser Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.46 | Columndm200labelLaserCurrent | read-only | optional | The value of this object provides the label of the Laser Bias Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.47 | Columndm200uomLaserCurrent | read-only | optional | The value of this object provides the Unit of Measure of the Laser Bias Current Analog parameter. The unit of measure for this parameter is mA |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.48 | Columndm200majorHighLaserCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the Laser Bias Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.49 | Columndm200majorLowLaserCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the Laser Bias Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.50 | Columndm200minorHighLaserCurrent | read-only | obsolete | The value of this object provides the Minor High alarm value of the Laser Bias Current Analog parameter. This object is not used by this module and always retu… |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.51 | Columndm200minorLowLaserCurrent | read-only | obsolete | The value of this object provides the Minor Low alarm value of the Laser Bias Current Analog parameter. This object is not used by this module and always retur… |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.52 | Columndm200currentValueLaserCurrent | read-only | mandatory | The value of this object provides the Current value of the Laser Bias Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.53 | Columndm200stateFlagLaserCurrent | read-only | mandatory | The value of this object provides the state of the Laser Bias Current Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.54 | Columndm200minValueLaserCurrent | read-only | mandatory | The value of this object provides the minimum value the Laser Bias Current Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.55 | Columndm200maxValueLaserCurrent | read-only | mandatory | The value of this object provides the maximum value the Laser Bias Current Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.56 | Columndm200alarmStateLaserCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the Laser Bias Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.57 | Columndm200labelTecCurrent | read-only | optional | The value of this object provides the label of the TEC Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.58 | Columndm200uomTecCurrent | read-only | optional | The value of this object provides the Unit of Measure of the TEC Current Analog parameter. The unit of measure for this parameter is mA |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.59 | Columndm200majorHighTecCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the TEC Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.60 | Columndm200majorLowTecCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.61 | Columndm200minorHighTecCurrent | read-only | obsolete | The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This object is not used by this module and always returns inv… |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.62 | Columndm200minorLowTecCurrent | read-only | obsolete | The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This object is not used by this module and always returns inva… |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.63 | Columndm200currentValueTecCurrent | read-only | mandatory | The value of this object provides the Current value of the TEC Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.64 | Columndm200stateFlagTecCurrent | read-only | mandatory | The value of this object provides the state of the TEC Current Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.65 | Columndm200minValueTecCurrent | read-only | mandatory | The value of this object provides the minimum value the TEC Current Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.66 | Columndm200maxValueTecCurrent | read-only | mandatory | The value of this object provides the maximum value the TEC Current Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.67 | Columndm200alarmStateTecCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the TEC Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.68 | Columndm200labelModTemp | read-only | optional | The value of this object provides the label of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.69 | Columndm200uomModTemp | read-only | optional | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. The unit of measure for this parameter is degrees C |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.70 | Columndm200majorHighModTemp | read-only | mandatory | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.71 | Columndm200majorLowModTemp | read-only | mandatory | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.72 | Columndm200minorHighModTemp | read-only | mandatory | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.73 | Columndm200minorLowModTemp | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.74 | Columndm200currentValueModTemp | read-only | mandatory | The value of this object provides the Current value of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.75 | Columndm200stateFlagModTemp | read-only | mandatory | The value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.76 | Columndm200minValueModTemp | read-only | mandatory | The value of this object provides the minimum value the Module Temperature Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.77 | Columndm200maxValueModTemp | read-only | mandatory | The value of this object provides the maximum value the Module Temperature Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.78 | Columndm200alarmStateModTemp | read-only | mandatory | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.79 | Columndm200labelFanCurrent | read-only | optional | The value of this object provides the label of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.80 | Columndm200uomFanCurrent | read-only | optional | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. The unit of measure for this parameter is mA |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.81 | Columndm200majorHighFanCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.82 | Columndm200majorLowFanCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.83 | Columndm200minorHighFanCurrent | read-only | obsolete | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This object is not used by this module and always returns inv… |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.84 | Columndm200minorLowFanCurrent | read-only | obsolete | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This object is not used by this module and always returns inva… |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.85 | Columndm200currentValueFanCurrent | read-only | mandatory | The value of this object provides the Current value of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.86 | Columndm200stateFlagFanCurrent | read-only | mandatory | The value of this object provides the state of the Fan Current Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.87 | Columndm200minValueFanCurrent | read-only | mandatory | The value of this object provides the minimum value the Fan Current Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.88 | Columndm200maxValueFanCurrent | read-only | mandatory | The value of this object provides the maximum value the Fan Current Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.89 | Columndm200alarmStateFanCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.3 | Tablegx2Dm200DigitalTable | not-accessible | mandatory | This table contains gx2Dm200m specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.19.3 | NodetrapDM200fanCurrentAlarm | This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.19.3.2 | Rowgx2Dm200DigitalEntry | not-accessible | mandatory | This list contains digital parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.19.3.2.1 | Columngx2Dm200DigitalTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.19.3.2.2 | Columndm200labelRfInput | read-only | optional | The value of this object provides the label of the RF Input Control Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.3.2.3 | Columndm200enumRfInput | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.19.3.2.4 | Columndm200valueRfInput | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.3.2.5 | Columndm200stateflagRfInput | read-only | mandatory | The value of this object provides the state of the RF Input Control Digital parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.19.3.2.6 | Columndm200labelOptOutput | read-only | optional | The value of this object provides the label of the Optical Output Control Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.3.2.7 | Columndm200enumOptOutput | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.19.3.2.8 | Columndm200valueOptOutput | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.3.2.9 | Columndm200stateflagOptOutput | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.19.3.2.10 | Columndm200labelSbsControl | read-only | optional | The value of this object provides the label of the SBS Control Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.3.2.11 | Columndm200enumSbsControl | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.19.3.2.12 | Columndm200valueSbsControl | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.3.2.13 | Columndm200stateflagSbsControl | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.19.3.2.14 | Columndm200labelFactoryDefault | read-only | optional | The value of this object provides the label of the Factory Default Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.3.2.15 | Columndm200enumFactoryDefault | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.19.3.2.16 | Columndm200valueFactoryDefault | read-write | mandatory | The value of this object is the current value of the parameter. Return value is meaningless |
| 1.3.6.1.4.1.1166.6.1.2.19.3.2.17 | Columndm200stateflagFactoryDefault | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.19.4 | Tablegx2Dm200StatusTable | not-accessible | mandatory | This table contains gx2Dm200 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.19.4 | NodetrapDM200ModuleTempAlarm | This trap is issued when the Module Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.19.4.3 | Rowgx2Dm200StatusEntry | not-accessible | mandatory | This list contains Status parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.19.4.3.1 | Columngx2Dm200StatusTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.19.4.3.2 | Columndm200labelBoot | read-only | optional | The value of this object provides the label of the Boot Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.4.3.3 | Columndm200valueBoot | read-only | mandatory | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| 1.3.6.1.4.1.1166.6.1.2.19.4.3.4 | Columndm200stateflagBoot | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.19.4.3.5 | Columndm200labelFlash | read-only | optional | The value of this object provides the label of the Flash Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.4.3.6 | Columndm200valueFlash | read-only | mandatory | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| 1.3.6.1.4.1.1166.6.1.2.19.4.3.7 | Columndm200stateflagFlash | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.19.4.3.8 | Columndm200labelFactoryDataCRC | read-only | optional | The value of this object provides the label of the Factory Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.4.3.9 | Columndm200valueFactoryDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| 1.3.6.1.4.1.1166.6.1.2.19.4.3.10 | Columndm200stateflagFactoryDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.19.4.3.11 | Columndm200labelLaserDataCRC | read-only | optional | The value of this object provides the label of the Laser Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.4.3.12 | Columndm200valueLaserDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| 1.3.6.1.4.1.1166.6.1.2.19.4.3.13 | Columndm200stateflagLaserDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.19.4.3.14 | Columndm200labelAlarmDataCrc | read-only | optional | The value of this object provides the label of the Alarm Data Crc parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.4.3.15 | Columndm200valueAlarmDataCrc | read-only | mandatory | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| 1.3.6.1.4.1.1166.6.1.2.19.4.3.16 | Columndm200stateflagAlarmDataCrc | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.19.4.3.17 | Columndm200labelRFInputStatus | read-only | optional | The value of this object provides the label of the Alarm Data Crc parameter. |
| 1.3.6.1.4.1.1166.6.1.2.19.4.3.18 | Columndm200valueRFInputStatus | read-only | mandatory | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| 1.3.6.1.4.1.1166.6.1.2.19.4.3.19 | Columndm200stateflagRFInputStatus | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.19.5 | Tablegx2Dm200FactoryTable | not-accessible | mandatory | This table contains gx2Dm200 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.19.5 | NodetrapDM200omiOffsetAlarm | This trap is issued when the OMI Offset goes out of range. | ||
| 1.3.6.1.4.1.1166.6.1.2.19.5.4 | Rowgx2Dm200FactoryEntry | not-accessible | mandatory | This list contains Factory parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.19.5.4.1 | Columngx2Dm200FactoryTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.19.5.4.2 | Columndm200bootControlByte | read-only | mandatory | The value of this object indicates which bank the firmware is currently being boot from. |
| 1.3.6.1.4.1.1166.6.1.2.19.5.4.3 | Columndm200bootStatusByte | read-only | mandatory | This object indicates the status of the last boot. Bit 2 = Bank 0/1 Active (0 = Bank 0, 1 = Bank 1), Bit 1 = Bank 1 Fail and Bit 0 = Bank 0 Fail (0 = Pass, 1 =… |
| 1.3.6.1.4.1.1166.6.1.2.19.5.4.4 | Columndm200bank1CRC | read-only | mandatory | This object provides the CRC code of bank 0. The display formate for the data is Hex. |
| 1.3.6.1.4.1.1166.6.1.2.19.5.4.5 | Columndm200bank2CRC | read-only | mandatory | This object provides the CRC code of bank 1.The display formate for the data is Hex. |
| 1.3.6.1.4.1.1166.6.1.2.19.5.4.6 | Columndm200prgEEPROMByte | read-only | mandatory | This object indicates if the EEPROM has been programmed |
| 1.3.6.1.4.1.1166.6.1.2.19.5.4.7 | Columndm200factoryCRC | read-only | mandatory | This object provides the CRC code for the Factory data. |
| 1.3.6.1.4.1.1166.6.1.2.19.5.4.8 | Columndm200calculateCRC | read-only | obsolete | This object indicates which of the Enums will have the CRC calculated. |
| 1.3.6.1.4.1.1166.6.1.2.19.5.4.9 | Columndm200hourMeter | read-only | mandatory | This object provides the hour meter reading of the module. |
| 1.3.6.1.4.1.1166.6.1.2.19.5.4.10 | Columndm200flashPrgCntA | read-only | mandatory | This object provides the number of times Bank 1 flash has been programmed. |
| 1.3.6.1.4.1.1166.6.1.2.19.5.4.11 | Columndm200flashPrgCntB | read-only | mandatory | This object provides the number of times Bank 1 flash has been programmed. |
| 1.3.6.1.4.1.1166.6.1.2.19.5.4.12 | Columndm200flashBankARev | read-only | mandatory | This object provides the revision of flash bank 0. The rev is 2 characters. |
| 1.3.6.1.4.1.1166.6.1.2.19.5.4.13 | Columndm200flashBankBRev | read-only | mandatory | This object provides the revision of flash bank 1. The rev is 2 characters. |
| 1.3.6.1.4.1.1166.6.1.2.19.6 | NodetrapDM200tecCurrentAlarm | This trap is issued when the TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.19.7 | NodetrapDM200LaserCurrentAlarm | This trap is issued when the Laser Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.19.8 | NodetrapDM200LaserTempAlarm | This trap is issued when the Laser Temp parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.19.9 | NodetrapDM200LaserPowerAlarm | This trap is issued when the Laser Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.19.10 | NodetrapDM200FlashAlarm | This trap is issued when the Laser Modules detects an error during Flash memory operations. | ||
| 1.3.6.1.4.1.1166.6.1.2.19.11 | NodetrapDM200BankBootAlarm | This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1. | ||
| 1.3.6.1.4.1.1166.6.1.2.19.12 | NodetrapDM200AlarmDataCRCAlarm | This trap is issued when the Alarm Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.19.13 | NodetrapDM200FactoryDataCRCAlarm | This trap is issued when the Factory Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.19.14 | NodetrapDM200CalDataCRCAlarm | This trap is issued when the Cal Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.19.15 | NodetrapDM200ResetFacDefault | This trap is issued when the DM200 resets to factory defaults | ||
| 1.3.6.1.4.1.1166.6.1.2.19.16 | NodetrapDM200UserRFOffAlarm | This trap is issued when the the User RF is turned off. | ||
| 1.3.6.1.4.1.1166.6.1.2.19.17 | NodetrapDM200UserOpticalOffAlarm | This trap is issued when the User Optical Power is turned off. | ||
| 1.3.6.1.4.1.1166.6.1.2.19.18 | NodetrapDM200UserSBSOffAlarm | This trap is issued when the User SBS is turned off. | ||
| 1.3.6.1.4.1.1166.6.1.2.19.19 | NodetrapDM200RFInputAlarm | This trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parame… | ||
| 1.3.6.1.4.1.1166.6.1.2.19.20 | NodetrapDM200RFOverloadAlarm | This trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this par… |