MIB Viewer

OMNI-gx2RFA1000-MIB

106 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.1166.6.1.2.22.1Nodegx2Rfa1000Descriptor
1.3.6.1.4.1.1166.6.1.2.22.1NodetrapRFA1000ConfigChangeIntegerThis trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre…
1.3.6.1.4.1.1166.6.1.2.22.2Tablegx2Rfa1000AnalogTablenot-accessiblemandatoryThis table contains gx2Rfa1000 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.22.2NodetrapRFA1000ConfigChangeDisplayStringThis trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may …
1.3.6.1.4.1.1166.6.1.2.22.2.1Rowgx2Rfa1000AnalogEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.22.2.1.1Columnrfagx2Rfa1000AnalogTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.22.2.1.2ColumnrfalabelModTempread-onlyoptionalThe value of this object provides the label of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.22.2.1.3ColumnrfauomModTempread-onlyoptionalThe value of this object provides the Unit of Measure of the Module Temperature Analog parameter. The unit of measure for this parameter is Degrees C
1.3.6.1.4.1.1166.6.1.2.22.2.1.4ColumnrfamajorHighModTempread-onlymandatoryThe value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.22.2.1.5ColumnrfamajorLowModTempread-onlymandatoryThe value of this object provides the Major Low alarm value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.22.2.1.6ColumnrfaminorHighModTempread-onlymandatoryThe value of this object provides the Minor High alarm value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.22.2.1.7ColumnrfaminorLowModTempread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.22.2.1.8ColumnrfacurrentValueModTempread-onlymandatoryThe value of this object provides the Current value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.22.2.1.9ColumnrfastateFlagModTempread-onlymandatoryThe value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.22.2.1.10ColumnrfaminValueModTempread-onlymandatoryThe value of this object provides the minimum value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.22.2.1.11ColumnrfamaxValueModTempread-onlymandatoryThe value of this object provides the maximum value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.22.2.1.12ColumnrfaalarmStateModTempread-onlymandatoryThe value of this object provides the curent alarm state of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.22.2.1.13ColumnrfalabelFanCurrentread-onlyoptionalThe value of this object provides the label of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.22.2.1.14ColumnrfauomFanCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the Fan Current Analog parameter. The unit of measure for this parameter is mA
1.3.6.1.4.1.1166.6.1.2.22.2.1.15ColumnrfamajorHighFanCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.22.2.1.16ColumnrfamajorLowFanCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.22.2.1.17ColumnrfaminorHighFanCurrentread-onlyobsoleteThe value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This object is not used by this module and always returns inv…
1.3.6.1.4.1.1166.6.1.2.22.2.1.18ColumnrfaminorLowFanCurrentread-onlyobsoleteThe value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This object is not used by this module and always returns inva…
1.3.6.1.4.1.1166.6.1.2.22.2.1.19ColumnrfacurrentValueFanCurrentread-onlymandatoryThe value of this object provides the Current value of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.22.2.1.20ColumnrfastateFlagFanCurrentread-onlymandatoryThe value of this object provides the state of the Fan Current Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.22.2.1.21ColumnrfaminValueFanCurrentread-onlymandatoryThe value of this object provides the minimum value of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.22.2.1.22ColumnrfamaxValueFanCurrentread-onlymandatoryThe value of this object provides the maximum value of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.22.2.1.23ColumnrfaalarmStateFanCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.22.2.1.24Columnrfalabel12Voltread-onlyoptionalThe value of this object provides the label of the 12v Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.22.2.1.25Columnrfauom12Voltread-onlyoptionalThe value of this object provides the Unit of Measure of the 12v Current Analog parameter. The unit of measure for this parameter is mA
1.3.6.1.4.1.1166.6.1.2.22.2.1.26ColumnrfamajorHigh12Voltread-onlymandatoryThe value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.22.2.1.27ColumnrfamajorLow12Voltread-onlymandatoryThe value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.22.2.1.28ColumnrfaminorHigh12Voltread-onlymandatoryThe value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.22.2.1.29ColumnrfaminorLow12Voltread-onlymandatoryThe value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.22.2.1.30ColumnrfacurrentValue12Voltread-onlymandatoryThe value of this object provides the Current value of the 12 Volt Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.22.2.1.31ColumnrfastateFlag12Voltread-onlymandatoryThe value of this object provides the state of the 12v Current Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.22.2.1.32ColumnrfaminValue12Voltread-onlymandatoryThe value of this object provides the minimum value of the 12 Volt Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.22.2.1.33ColumnrfamaxValue12Voltread-onlymandatoryThe value of this object provides the maximum value of the 12 Volt Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.22.2.1.34ColumnrfaalarmState12Voltread-onlymandatoryThe value of this object provides the curent alarm state of the 12v Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.22.3Tablegx2Rfa1000DigitalTablenot-accessiblemandatoryThis table contains gx2Rfa1000 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.22.3NodetrapRFA1000ModuleTemperatureAlarmThis trap is issued when the RFA1000 Module's Temperature goes out of range.
1.3.6.1.4.1.1166.6.1.2.22.3.2Rowgx2Rfa1000DigitalEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.22.3.2.1Columnrfagx2Rfa1000DigitalTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.22.3.2.2ColumnrfalabelSlopeSettingread-onlyoptionalThe value of this object provides the label of the RX1000's AttnSetting Digital parameter.
1.3.6.1.4.1.1166.6.1.2.22.3.2.3ColumnrfaenumSlopeSettingread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.22.3.2.4ColumnrfavalueSlopeSettingread-writemandatoryThe value of this object is the current value of the parameter. It is an integer value from 1 to 7. Each increment represents 1/2 dB of slope from 1 to 4 dB. W…
1.3.6.1.4.1.1166.6.1.2.22.3.2.5ColumnrfastateFlagSlopeSettingread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.22.3.2.6ColumnrfalabelAttnSettingread-onlyoptionalThe value of this object provides the label of the RX1000's AttnSetting Digital parameter.
1.3.6.1.4.1.1166.6.1.2.22.3.2.7ColumnrfaenumAttnSettingread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.22.3.2.8ColumnrfavalueAttnSettingread-writemandatoryThe value of this object is the current value of the parameter. It is an integer value from 1to 21 Each increment represents 1/4 dB of attenuation from 0 to 5 …
1.3.6.1.4.1.1166.6.1.2.22.3.2.9ColumnrfastateFlagAttnSettingread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.22.3.2.10ColumnrfalabelFactoryDefaultread-onlyoptionalThe value of this object provides the label of the Factory Default Reset Digital parameter.
1.3.6.1.4.1.1166.6.1.2.22.3.2.11ColumnrfaenumFactoryDefaultread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.22.3.2.12ColumnrfavalueFactoryDefaultread-writemandatoryThe value of this object is the current value of the parameter.This parameter will always read off(1)
1.3.6.1.4.1.1166.6.1.2.22.3.2.13ColumnrfastateFlagFactoryDefaultread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.22.4Tablegx2Rfa1000StatusTablenot-accessiblemandatoryThis table contains gx2Rfa1000 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.22.4NodetrapRFA1000FanCurrentAlarmThis trap is issued when the RFA1000 Module's Fan Currrent parameter goes out of range.
1.3.6.1.4.1.1166.6.1.2.22.4.3Rowgx2Rfa1000StatusEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.22.4.3.1Columnrfagx2Rfa1000StatusTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.22.4.3.2ColumnrfalabelBootread-onlyoptionalThe value of this object provides the label of the Boot Status Status parameter.
1.3.6.1.4.1.1166.6.1.2.22.4.3.3ColumnrfavalueBootread-onlymandatoryThe value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
1.3.6.1.4.1.1166.6.1.2.22.4.3.4ColumnrfastateflagBootread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.22.4.3.5ColumnrfalabelFlashread-onlyoptionalThe value of this object provides the label of the Flash Status Status parameter.
1.3.6.1.4.1.1166.6.1.2.22.4.3.6ColumnrfavalueFlashread-onlymandatoryThe value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
1.3.6.1.4.1.1166.6.1.2.22.4.3.7ColumnrfastateflagFlashread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.22.4.3.8ColumnrfalabelFactoryDataCRCread-onlyoptionalThe value of this object provides the label of the Factory Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.22.4.3.9ColumnrfavalueFactoryDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
1.3.6.1.4.1.1166.6.1.2.22.4.3.10ColumnrfastateflagFactoryDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.22.4.3.11ColumnrfalabelAlarmDataCRCread-onlyoptionalThe value of this object provides the label of the Alarm Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.22.4.3.12ColumnrfavalueAlarmDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
1.3.6.1.4.1.1166.6.1.2.22.4.3.13ColumnrfastateflagAlarmDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.22.4.3.14ColumnrfalabelSlopeCalDataCRCread-onlyoptionalThe value of this object provides the label of the Calibration Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.22.4.3.15ColumnrfavalueSlopeCalDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
1.3.6.1.4.1.1166.6.1.2.22.4.3.16ColumnrfastateflagSlopeCalDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.22.4.3.17ColumnrfalabelAttnCalDataCRCread-onlyoptionalThe value of this object provides the label of the Factor Cal Setting CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.22.4.3.18ColumnrfavalueAttnCalDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
1.3.6.1.4.1.1166.6.1.2.22.4.3.19ColumnrfastateflagAttnCalDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.22.5Tablegx2Rfa1000FactoryTablenot-accessiblemandatoryThis table contains gx2Rfa1000 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.22.5NodetrapRFA1000Plus12CurrentAlarmThis trap is issued when the RFA1000 Module's positive 12 volt current parameter goes out of range.
1.3.6.1.4.1.1166.6.1.2.22.5.4Rowgx2Rfa1000FactoryEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.22.5.4.1Columnrfagx2Rfa1000FactoryTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.22.5.4.2ColumnrfabootControlByteread-onlymandatoryThe value of this object indicates which bank the firmware is currently being boot from.
1.3.6.1.4.1.1166.6.1.2.22.5.4.3ColumnrfabootStatusByteread-onlymandatoryThis object indicates the status of the last boot
1.3.6.1.4.1.1166.6.1.2.22.5.4.4Columnrfabank0CRCread-onlymandatoryThis object provides the CRC code of bank 0.
1.3.6.1.4.1.1166.6.1.2.22.5.4.5Columnrfabank1CRCread-onlymandatoryThis object provides the CRC code of bank 1.
1.3.6.1.4.1.1166.6.1.2.22.5.4.6ColumnrfaprgEEPROMByteread-onlymandatoryThis object indicates if the EEPROM has been programmed
1.3.6.1.4.1.1166.6.1.2.22.5.4.7ColumnrfafactoryCRCread-onlymandatoryThis object provides the CRC code for the Factory data.
1.3.6.1.4.1.1166.6.1.2.22.5.4.8ColumnrfacalculateCRCread-onlyobsoleteThis object indicates which of the Emnums will have the CRC calculated.
1.3.6.1.4.1.1166.6.1.2.22.5.4.9ColumnrfahourMeterread-onlymandatoryThis object provides the hour meter reading of the module.
1.3.6.1.4.1.1166.6.1.2.22.5.4.10ColumnrfaflashPrgCntAread-onlymandatoryThis object provides the number of times the flash has been programmed on side A.
1.3.6.1.4.1.1166.6.1.2.22.5.4.11ColumnrfaflashPrgCntBread-onlymandatoryThis object provides the number of times the flash has been programmed on side B.
1.3.6.1.4.1.1166.6.1.2.22.5.4.12ColumnrfafwRev0read-onlymandatoryThis object provides the Revision of the firmware stores in bank 0.
1.3.6.1.4.1.1166.6.1.2.22.5.4.13ColumnrfafwRev1read-onlymandatoryThis object provides the Revision of the firmware stores in bank 1.
1.3.6.1.4.1.1166.6.1.2.22.6Tablegx2Rfa1000HoldTimeTablenot-accessiblemandatoryThis table contains gx2Rfa1000 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.22.6NodetrapRFA1000Boot0AlarmThis trap is issued when the RFA1000 Module's Bank 0 Boot sequence has detected an error.
1.3.6.1.4.1.1166.6.1.2.22.6.5Rowgx2Rfa1000HoldTimeEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.22.6.5.1Columngx2Rfa1000HoldTimeTableIndexread-onlymandatoryThe value of this object is the index of the data object.
1.3.6.1.4.1.1166.6.1.2.22.6.5.2Columngx2Rfa1000HoldTimeSpecIndexread-onlymandatoryThe value of this object identifies the index of the alarm object to be modified.
1.3.6.1.4.1.1166.6.1.2.22.6.5.3Columngx2Rfa1000HoldTimeDataread-writemandatoryThe value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered…
1.3.6.1.4.1.1166.6.1.2.22.7NodetrapRFA1000Boot1AlarmThis trap is issued when the RFA1000 Module's Bank 1 Boot sequence has detected an error.
1.3.6.1.4.1.1166.6.1.2.22.8NodetrapRFA1000FlashAlarmThis trap is issued when the RFA1000 Module's boot or flash programming sequence has detected a Flash error.
1.3.6.1.4.1.1166.6.1.2.22.9NodetrapRFA1000AlarmDataCRCAlarmThis trap is issued when the RFA1000 Module detects an error calculating the alarm limit CRC.
1.3.6.1.4.1.1166.6.1.2.22.10NodetrapRFA1000FactoryDataCRCAlarmThis trap is issued when the RFA1000 Module detects an error calculating the Factory data CRC.
1.3.6.1.4.1.1166.6.1.2.22.11NodetrapRFA1000SlopeCalDataCRCAlarmThis trap is issued when the RFA1000 Module detects an error calculating the Slope Calibration data CRC.
1.3.6.1.4.1.1166.6.1.2.22.12NodetrapRFA1000AttnCalDataCRCAlarmThis trap is issued when the RFA1000 Module detects an Attenuation Calibration Data CRC alarm.
1.3.6.1.4.1.1166.6.1.2.22.13NodetrapRFA1000ResetFacDefaultThis trap is issued when the RFA1000 resets to factory defaults