OMNI-gx2RFA1000-MIB
106 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.22.1 | Nodegx2Rfa1000Descriptor | |||
| 1.3.6.1.4.1.1166.6.1.2.22.1 | NodetrapRFA1000ConfigChangeInteger | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre… | ||
| 1.3.6.1.4.1.1166.6.1.2.22.2 | Tablegx2Rfa1000AnalogTable | not-accessible | mandatory | This table contains gx2Rfa1000 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.22.2 | NodetrapRFA1000ConfigChangeDisplayString | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may … | ||
| 1.3.6.1.4.1.1166.6.1.2.22.2.1 | Rowgx2Rfa1000AnalogEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.1 | Columnrfagx2Rfa1000AnalogTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.2 | ColumnrfalabelModTemp | read-only | optional | The value of this object provides the label of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.3 | ColumnrfauomModTemp | read-only | optional | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. The unit of measure for this parameter is Degrees C |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.4 | ColumnrfamajorHighModTemp | read-only | mandatory | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.5 | ColumnrfamajorLowModTemp | read-only | mandatory | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.6 | ColumnrfaminorHighModTemp | read-only | mandatory | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.7 | ColumnrfaminorLowModTemp | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.8 | ColumnrfacurrentValueModTemp | read-only | mandatory | The value of this object provides the Current value of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.9 | ColumnrfastateFlagModTemp | read-only | mandatory | The value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.10 | ColumnrfaminValueModTemp | read-only | mandatory | The value of this object provides the minimum value of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.11 | ColumnrfamaxValueModTemp | read-only | mandatory | The value of this object provides the maximum value of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.12 | ColumnrfaalarmStateModTemp | read-only | mandatory | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.13 | ColumnrfalabelFanCurrent | read-only | optional | The value of this object provides the label of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.14 | ColumnrfauomFanCurrent | read-only | optional | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. The unit of measure for this parameter is mA |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.15 | ColumnrfamajorHighFanCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.16 | ColumnrfamajorLowFanCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.17 | ColumnrfaminorHighFanCurrent | read-only | obsolete | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This object is not used by this module and always returns inv… |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.18 | ColumnrfaminorLowFanCurrent | read-only | obsolete | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This object is not used by this module and always returns inva… |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.19 | ColumnrfacurrentValueFanCurrent | read-only | mandatory | The value of this object provides the Current value of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.20 | ColumnrfastateFlagFanCurrent | read-only | mandatory | The value of this object provides the state of the Fan Current Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.21 | ColumnrfaminValueFanCurrent | read-only | mandatory | The value of this object provides the minimum value of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.22 | ColumnrfamaxValueFanCurrent | read-only | mandatory | The value of this object provides the maximum value of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.23 | ColumnrfaalarmStateFanCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.24 | Columnrfalabel12Volt | read-only | optional | The value of this object provides the label of the 12v Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.25 | Columnrfauom12Volt | read-only | optional | The value of this object provides the Unit of Measure of the 12v Current Analog parameter. The unit of measure for this parameter is mA |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.26 | ColumnrfamajorHigh12Volt | read-only | mandatory | The value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.27 | ColumnrfamajorLow12Volt | read-only | mandatory | The value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.28 | ColumnrfaminorHigh12Volt | read-only | mandatory | The value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.29 | ColumnrfaminorLow12Volt | read-only | mandatory | The value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.30 | ColumnrfacurrentValue12Volt | read-only | mandatory | The value of this object provides the Current value of the 12 Volt Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.31 | ColumnrfastateFlag12Volt | read-only | mandatory | The value of this object provides the state of the 12v Current Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.32 | ColumnrfaminValue12Volt | read-only | mandatory | The value of this object provides the minimum value of the 12 Volt Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.33 | ColumnrfamaxValue12Volt | read-only | mandatory | The value of this object provides the maximum value of the 12 Volt Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.2.1.34 | ColumnrfaalarmState12Volt | read-only | mandatory | The value of this object provides the curent alarm state of the 12v Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.3 | Tablegx2Rfa1000DigitalTable | not-accessible | mandatory | This table contains gx2Rfa1000 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.22.3 | NodetrapRFA1000ModuleTemperatureAlarm | This trap is issued when the RFA1000 Module's Temperature goes out of range. | ||
| 1.3.6.1.4.1.1166.6.1.2.22.3.2 | Rowgx2Rfa1000DigitalEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.22.3.2.1 | Columnrfagx2Rfa1000DigitalTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.22.3.2.2 | ColumnrfalabelSlopeSetting | read-only | optional | The value of this object provides the label of the RX1000's AttnSetting Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.3.2.3 | ColumnrfaenumSlopeSetting | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.22.3.2.4 | ColumnrfavalueSlopeSetting | read-write | mandatory | The value of this object is the current value of the parameter. It is an integer value from 1 to 7. Each increment represents 1/2 dB of slope from 1 to 4 dB. W… |
| 1.3.6.1.4.1.1166.6.1.2.22.3.2.5 | ColumnrfastateFlagSlopeSetting | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.22.3.2.6 | ColumnrfalabelAttnSetting | read-only | optional | The value of this object provides the label of the RX1000's AttnSetting Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.3.2.7 | ColumnrfaenumAttnSetting | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.22.3.2.8 | ColumnrfavalueAttnSetting | read-write | mandatory | The value of this object is the current value of the parameter. It is an integer value from 1to 21 Each increment represents 1/4 dB of attenuation from 0 to 5 … |
| 1.3.6.1.4.1.1166.6.1.2.22.3.2.9 | ColumnrfastateFlagAttnSetting | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.22.3.2.10 | ColumnrfalabelFactoryDefault | read-only | optional | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.3.2.11 | ColumnrfaenumFactoryDefault | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.22.3.2.12 | ColumnrfavalueFactoryDefault | read-write | mandatory | The value of this object is the current value of the parameter.This parameter will always read off(1) |
| 1.3.6.1.4.1.1166.6.1.2.22.3.2.13 | ColumnrfastateFlagFactoryDefault | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.22.4 | Tablegx2Rfa1000StatusTable | not-accessible | mandatory | This table contains gx2Rfa1000 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.22.4 | NodetrapRFA1000FanCurrentAlarm | This trap is issued when the RFA1000 Module's Fan Currrent parameter goes out of range. | ||
| 1.3.6.1.4.1.1166.6.1.2.22.4.3 | Rowgx2Rfa1000StatusEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.22.4.3.1 | Columnrfagx2Rfa1000StatusTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.22.4.3.2 | ColumnrfalabelBoot | read-only | optional | The value of this object provides the label of the Boot Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.4.3.3 | ColumnrfavalueBoot | read-only | mandatory | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| 1.3.6.1.4.1.1166.6.1.2.22.4.3.4 | ColumnrfastateflagBoot | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.22.4.3.5 | ColumnrfalabelFlash | read-only | optional | The value of this object provides the label of the Flash Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.4.3.6 | ColumnrfavalueFlash | read-only | mandatory | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| 1.3.6.1.4.1.1166.6.1.2.22.4.3.7 | ColumnrfastateflagFlash | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.22.4.3.8 | ColumnrfalabelFactoryDataCRC | read-only | optional | The value of this object provides the label of the Factory Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.4.3.9 | ColumnrfavalueFactoryDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| 1.3.6.1.4.1.1166.6.1.2.22.4.3.10 | ColumnrfastateflagFactoryDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.22.4.3.11 | ColumnrfalabelAlarmDataCRC | read-only | optional | The value of this object provides the label of the Alarm Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.4.3.12 | ColumnrfavalueAlarmDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| 1.3.6.1.4.1.1166.6.1.2.22.4.3.13 | ColumnrfastateflagAlarmDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.22.4.3.14 | ColumnrfalabelSlopeCalDataCRC | read-only | optional | The value of this object provides the label of the Calibration Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.4.3.15 | ColumnrfavalueSlopeCalDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| 1.3.6.1.4.1.1166.6.1.2.22.4.3.16 | ColumnrfastateflagSlopeCalDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.22.4.3.17 | ColumnrfalabelAttnCalDataCRC | read-only | optional | The value of this object provides the label of the Factor Cal Setting CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.22.4.3.18 | ColumnrfavalueAttnCalDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| 1.3.6.1.4.1.1166.6.1.2.22.4.3.19 | ColumnrfastateflagAttnCalDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.22.5 | Tablegx2Rfa1000FactoryTable | not-accessible | mandatory | This table contains gx2Rfa1000 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.22.5 | NodetrapRFA1000Plus12CurrentAlarm | This trap is issued when the RFA1000 Module's positive 12 volt current parameter goes out of range. | ||
| 1.3.6.1.4.1.1166.6.1.2.22.5.4 | Rowgx2Rfa1000FactoryEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.22.5.4.1 | Columnrfagx2Rfa1000FactoryTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.22.5.4.2 | ColumnrfabootControlByte | read-only | mandatory | The value of this object indicates which bank the firmware is currently being boot from. |
| 1.3.6.1.4.1.1166.6.1.2.22.5.4.3 | ColumnrfabootStatusByte | read-only | mandatory | This object indicates the status of the last boot |
| 1.3.6.1.4.1.1166.6.1.2.22.5.4.4 | Columnrfabank0CRC | read-only | mandatory | This object provides the CRC code of bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.22.5.4.5 | Columnrfabank1CRC | read-only | mandatory | This object provides the CRC code of bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.22.5.4.6 | ColumnrfaprgEEPROMByte | read-only | mandatory | This object indicates if the EEPROM has been programmed |
| 1.3.6.1.4.1.1166.6.1.2.22.5.4.7 | ColumnrfafactoryCRC | read-only | mandatory | This object provides the CRC code for the Factory data. |
| 1.3.6.1.4.1.1166.6.1.2.22.5.4.8 | ColumnrfacalculateCRC | read-only | obsolete | This object indicates which of the Emnums will have the CRC calculated. |
| 1.3.6.1.4.1.1166.6.1.2.22.5.4.9 | ColumnrfahourMeter | read-only | mandatory | This object provides the hour meter reading of the module. |
| 1.3.6.1.4.1.1166.6.1.2.22.5.4.10 | ColumnrfaflashPrgCntA | read-only | mandatory | This object provides the number of times the flash has been programmed on side A. |
| 1.3.6.1.4.1.1166.6.1.2.22.5.4.11 | ColumnrfaflashPrgCntB | read-only | mandatory | This object provides the number of times the flash has been programmed on side B. |
| 1.3.6.1.4.1.1166.6.1.2.22.5.4.12 | ColumnrfafwRev0 | read-only | mandatory | This object provides the Revision of the firmware stores in bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.22.5.4.13 | ColumnrfafwRev1 | read-only | mandatory | This object provides the Revision of the firmware stores in bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.22.6 | Tablegx2Rfa1000HoldTimeTable | not-accessible | mandatory | This table contains gx2Rfa1000 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.22.6 | NodetrapRFA1000Boot0Alarm | This trap is issued when the RFA1000 Module's Bank 0 Boot sequence has detected an error. | ||
| 1.3.6.1.4.1.1166.6.1.2.22.6.5 | Rowgx2Rfa1000HoldTimeEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.22.6.5.1 | Columngx2Rfa1000HoldTimeTableIndex | read-only | mandatory | The value of this object is the index of the data object. |
| 1.3.6.1.4.1.1166.6.1.2.22.6.5.2 | Columngx2Rfa1000HoldTimeSpecIndex | read-only | mandatory | The value of this object identifies the index of the alarm object to be modified. |
| 1.3.6.1.4.1.1166.6.1.2.22.6.5.3 | Columngx2Rfa1000HoldTimeData | read-write | mandatory | The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered… |
| 1.3.6.1.4.1.1166.6.1.2.22.7 | NodetrapRFA1000Boot1Alarm | This trap is issued when the RFA1000 Module's Bank 1 Boot sequence has detected an error. | ||
| 1.3.6.1.4.1.1166.6.1.2.22.8 | NodetrapRFA1000FlashAlarm | This trap is issued when the RFA1000 Module's boot or flash programming sequence has detected a Flash error. | ||
| 1.3.6.1.4.1.1166.6.1.2.22.9 | NodetrapRFA1000AlarmDataCRCAlarm | This trap is issued when the RFA1000 Module detects an error calculating the alarm limit CRC. | ||
| 1.3.6.1.4.1.1166.6.1.2.22.10 | NodetrapRFA1000FactoryDataCRCAlarm | This trap is issued when the RFA1000 Module detects an error calculating the Factory data CRC. | ||
| 1.3.6.1.4.1.1166.6.1.2.22.11 | NodetrapRFA1000SlopeCalDataCRCAlarm | This trap is issued when the RFA1000 Module detects an error calculating the Slope Calibration data CRC. | ||
| 1.3.6.1.4.1.1166.6.1.2.22.12 | NodetrapRFA1000AttnCalDataCRCAlarm | This trap is issued when the RFA1000 Module detects an Attenuation Calibration Data CRC alarm. | ||
| 1.3.6.1.4.1.1166.6.1.2.22.13 | NodetrapRFA1000ResetFacDefault | This trap is issued when the RFA1000 resets to factory defaults |