OMNI-gx2RSW1000B-MIB
167 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.18.1 | Nodegx2Rsw1000bDescriptor | |||
| 1.3.6.1.4.1.1166.6.1.2.18.1 | NodetrapRSW1000bConfigChangeInteger | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre… | ||
| 1.3.6.1.4.1.1166.6.1.2.18.2 | Tablegx2Rsw1000bAnalogTable | not-accessible | mandatory | This table contains gx2Rsw1000b specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.18.2 | NodetrapRSW1000bConfigChangeDisplayString | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may … | ||
| 1.3.6.1.4.1.1166.6.1.2.18.2.1 | Rowgx2Rsw1000bAnalogEntry | not-accessible | mandatory | This list contains the analog parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.1 | Columngx2Rsw1000bAnalogTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.2 | Columnrsw1000blabelPriRFInputLvl | read-only | optional | The value of this object provides the label of the Primary RF Input Level Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.3 | Columnrsw1000buomPriRFInputLvl | read-only | optional | The value of this object provides the Unit of Measure of the Primary RF Input Level Analog parameter. For all analog objects for this parameter type, the Unit … |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.4 | Columnrsw1000bmajorHighPriRFInputLvl | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object… |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.5 | Columnrsw1000bmajorLowPriRFInputLvl | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object… |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.6 | Columnrsw1000bminorHighPriRFInputLvl | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object… |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.7 | Columnrsw1000bminorLowPriRFInputLvl | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object… |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.8 | Columnrsw1000bcurrentValuePriRFInputLvl | read-only | mandatory | The value of this object provides the current value of the Primary RF Input Level Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.9 | Columnrsw1000bstateFlagPriRFInputLvl | read-only | mandatory | The value of this object provides the state of the Primary RF Input Level Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.10 | Columnrsw1000bminValuePriRFInputLvl | read-only | mandatory | The value of this object represents a gauge minimum limit for the Primary RF Input Level Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.11 | Columnrsw1000bmaxValuePriRFInputLvl | read-only | mandatory | The value of this object represents a gauge maximum limit for the Primary RF Input Level Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.12 | Columnrsw1000balarmStatePriRFInputLvl | read-only | mandatory | The value of this object provides the curent alarm state of the Primary RF Input Level Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.13 | Columnrsw1000blabelSecRFInputLvl | read-only | optional | The value of this object provides the label of the Secondary RF Input Level Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.14 | Columnrsw1000buomSecRFInputLvl | read-only | optional | The value of this object provides the Unit of Measure of the Secondary RF Input Level Analog parameter. For all analog objects for this parameter type, the Uni… |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.15 | Columnrsw1000bmajorHighSecRFInputLvl | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object… |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.16 | Columnrsw1000bmajorLowSecRFInputLvl | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object… |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.17 | Columnrsw1000bminorHighSecRFInputLvl | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object… |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.18 | Columnrsw1000bminorLowSecRFInputLvl | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object… |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.19 | Columnrsw1000bcurrentValueSecRFInputLvl | read-only | mandatory | The value of this object provides the current value of the Secondary RF Input Level Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.20 | Columnrsw1000bstateFlagSecRFInputLvl | read-only | mandatory | The value of this object provides the state of the Secondary RF Input Level Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.21 | Columnrsw1000bminValueSecRFInputLvl | read-only | mandatory | The value of this object represents a gauge minimum limit for the Secondary RF Input Level Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.22 | Columnrsw1000bmaxValueSecRFInputLvl | read-only | mandatory | The value of this object represents a gauge maximum limit for the Secondary RF Input Level Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.23 | Columnrsw1000balarmStateSecRFInputLvl | read-only | mandatory | The value of this object provides the curent alarm state of the Secondary RF Input Level Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.24 | Columnrsw1000blabelPriRFThreshold | read-only | optional | The value of this object provides the label of the Primary RF Threshold Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.25 | Columnrsw1000buomPriRFThreshold | read-only | optional | The value of this object provides the Unit of Measure of the Primary RF Threshold Analog parameter. For all analog objects for this parameter type, the Unit of… |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.26 | Columnrsw1000bmajorHighPriRFThreshold | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object… |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.27 | Columnrsw1000bmajorLowPriRFThreshold | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object… |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.28 | Columnrsw1000bminorHighPriRFThreshold | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object… |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.29 | Columnrsw1000bminorLowPriRFThreshold | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object… |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.30 | Columnrsw1000bcurrentValuePriRFThreshold | read-write | mandatory | The value of this object provides the current value of the Primary RF Threshold Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.31 | Columnrsw1000bstateFlagPriRFThreshold | read-only | mandatory | The value of this object provides the state of the Primary RF Threshold Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.32 | Columnrsw1000bminValuePriRFThreshold | read-only | mandatory | The value of this object represents a gauge minimum limit for the Primary RF Threshold Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.33 | Columnrsw1000bmaxValuePriRFThreshold | read-only | mandatory | The value of this object represents a gauge maximum limit for the Primary RF Threshold Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.34 | Columnrsw1000balarmStatePriRFThreshold | read-only | mandatory | The value of this object provides the curent alarm state of the Primary RF Threshold Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.35 | Columnrsw1000blabelSecRFThreshold | read-only | optional | The value of this object provides the label of the Secondary RF Threshold Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.36 | Columnrsw1000buomSecRFThreshold | read-only | optional | The value of this object provides the Unit of Measure of the Secondary RF Threshold Analog parameter. For all analog objects for this parameter type, the Unit … |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.37 | Columnrsw1000bmajorHighSecRFThreshold | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object… |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.38 | Columnrsw1000bmajorLowSecRFThreshold | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object… |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.39 | Columnrsw1000bminorHighSecRFThreshold | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object… |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.40 | Columnrsw1000bminorLowSecRFThreshold | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object… |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.41 | Columnrsw1000bcurrentValueSecRFThreshold | read-write | mandatory | The value of this object provides the current value of the Secondary RF Threshold Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.42 | Columnrsw1000bstateFlagSecRFThreshold | read-only | mandatory | The value of this object provides the state of the Secondary RF Threshold Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.43 | Columnrsw1000bminValueSecRFThreshold | read-only | mandatory | The value of this object represents a gauge minimum limit for the Secondary RF Threshold Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.44 | Columnrsw1000bmaxValueSecRFThreshold | read-only | mandatory | The value of this object represents a gauge maximum limit for the Secondary RF Threshold Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.45 | Columnrsw1000balarmStateSecRFThreshold | read-only | mandatory | The value of this object provides the curent alarm state of the Secondary RF Threshold Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.46 | Columnrsw1000blabelModTemp | read-only | optional | The value of this object provides the label of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.47 | Columnrsw1000buomModTemp | read-only | optional | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. For all analog objects for this parameter type, the Unit of M… |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.48 | Columnrsw1000bmajorHighModTemp | read-only | mandatory | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.49 | Columnrsw1000bmajorLowModTemp | read-only | mandatory | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.50 | Columnrsw1000bminorHighModTemp | read-only | mandatory | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.51 | Columnrsw1000bminorLowModTemp | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.52 | Columnrsw1000bcurrentValueModTemp | read-only | mandatory | The value of this object provides the Current value of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.53 | Columnrsw1000bstateFlagModTemp | read-only | mandatory | The value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.54 | Columnrsw1000bminValueModTemp | read-only | mandatory | The value of this object represents a gauge minimum limit for the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.55 | Columnrsw1000bmaxValueModTemp | read-only | mandatory | The value of this object represents a gauge maximum limit for the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.56 | Columnrsw1000balarmStateModTemp | read-only | mandatory | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.57 | Columnrsw1000blabelFanCurrent | read-only | optional | The value of this object provides the label of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.58 | Columnrsw1000buomFanCurrent | read-only | optional | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. For all analog objects for this parameter type, the Unit of Measure … |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.59 | Columnrsw1000bmajorHighFanCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.60 | Columnrsw1000bmajorLowFanCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.61 | Columnrsw1000bminorHighFanCurrent | read-only | obsolete | This object is not used by this module and always returns invalid floating point value of 0xFFFFFFFF. This object is kept here for persistence. The value of th… |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.62 | Columnrsw1000bminorLowFanCurrent | read-only | obsolete | This object is not used by this module and always returns invalid floating point value of 0xFFFFFFFF. This object is kept here for persistence. The value of th… |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.63 | Columnrsw1000bcurrentValueFanCurrent | read-only | mandatory | The value of this object provides the Current value of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.64 | Columnrsw1000bstateFlagFanCurrent | read-only | mandatory | The value of this object provides the state of the Fan Current Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.65 | Columnrsw1000bminValueFanCurrent | read-only | mandatory | The value of this object represents a gauge minimum limit for the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.66 | Columnrsw1000bmaxValueFanCurrent | read-only | mandatory | The value of this object represents a gauge maximum limit for the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.2.1.67 | Columnrsw1000balarmStateFanCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.3 | Tablegx2Rsw1000bDigitalTable | not-accessible | mandatory | This table contains gx2Rsw1000b specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.18.3 | NodetrapRSW1000bRFInputAlarm | This trap is issued when the Switch Control signals go out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.18.3.2 | Rowgx2Rsw1000bDigitalEntry | not-accessible | mandatory | This list contains digital parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.1 | Columngx2Rsw1000bDigitalTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.2 | Columnrsw1000blabelSwitchControl | read-only | optional | The value of this object provides the label of the Switch Control Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.3 | Columnrsw1000benumSwitchControl | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.4 | Columnrsw1000bvalueSwitchControl | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.5 | Columnrsw1000bstateflagSwitchControl | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.6 | Columnrsw1000blabelSwitchMode | read-only | optional | The value of this object provides the label of the Revert Mode Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.7 | Columnrsw1000benumSwitchMode | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.8 | Columnrsw1000bvalueSwitchMode | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.9 | Columnrsw1000bstateflagSwitchMode | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.10 | Columnrsw1000blabelRevertEnable | read-only | optional | The value of this object provides the label of the Revert Enable Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.11 | Columnrsw1000benumRevertEnable | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.12 | Columnrsw1000bvalueRevertEnable | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.13 | Columnrsw1000bstateflagRevertEnable | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.14 | Columnrsw1000blabelRevertTime | read-only | optional | The value of this object provides the label of the Revert Time Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.15 | Columnrsw1000benumRevertTime | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.16 | Columnrsw1000bvalueRevertTime | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.17 | Columnrsw1000bstateflagRevertTime | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.18 | Columnrsw1000blabelSensorMode | read-only | optional | The value of this object provides the label of the SensorMode Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.19 | Columnrsw1000benumSensorMode | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.20 | Columnrsw1000bvalueSensorMode | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.21 | Columnrsw1000bstateflagSensorMode | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.22 | Columnrsw1000blabelSwitchMonitor | read-only | optional | The value of this object provides the label of the Switch Monitor Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.23 | Columnrsw1000benumSwitchMonitor | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.24 | Columnrsw1000bvalueSwitchMonitor | read-only | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.25 | Columnrsw1000bstateflagSwitchMonitor | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.26 | Columnrsw1000blabelPriStatusSig | read-only | optional | The value of this object provides the label of the Primary Control Signal Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.27 | Columnrsw1000benumPriStatusSig | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.28 | Columnrsw1000bvaluePriStatusSig | read-only | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.29 | Columnrsw1000bstateflagPriStatusSig | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.30 | Columnrsw1000blabelSecStatusSig | read-only | optional | The value of this object provides the label of the Secondary Control Signal Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.31 | Columnrsw1000benumSecStatusSig | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.32 | Columnrsw1000bvalueSecStatusSig | read-only | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.33 | Columnrsw1000bstateflagSecStatusSig | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.34 | Columnrsw1000blabelFactoryDefault | read-only | optional | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.35 | Columnrsw1000benumFactoryDefault | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.36 | Columnrsw1000bvalueFactoryDefault | read-write | mandatory | This is a one-shot control value. A read of this value is always the value corresponding to off(1). A write of the value corresponding to on(2) results in effe… |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.37 | Columnrsw1000bstateflagFactoryDefault | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.18.4 | Tablegx2Rsw1000bStatusTable | not-accessible | mandatory | This table contains gx2Rsw1000b specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.18.4 | NodetrapRSW1000bFanCurrentAlarm | This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.18.4.3 | Rowgx2Rsw1000bStatusEntry | not-accessible | mandatory | This list contains Status parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.18.4.3.1 | Columngx2Rsw1000bStatusTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.18.4.3.2 | Columnrsw1000blabelBoot | read-only | optional | The value of this object provides the label of the Boot Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.4.3.3 | Columnrsw1000bvalueBoot | read-only | mandatory | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| 1.3.6.1.4.1.1166.6.1.2.18.4.3.4 | Columnrsw1000bstateflagBoot | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.18.4.3.5 | Columnrsw1000blabelFlash | read-only | optional | The value of this object provides the label of the Flash Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.4.3.6 | Columnrsw1000bvalueFlash | read-only | mandatory | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| 1.3.6.1.4.1.1166.6.1.2.18.4.3.7 | Columnrsw1000bstateflagFlash | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.18.4.3.8 | Columnrsw1000blabelFactoryDataCRC | read-only | optional | The value of this object provides the label of the Factory Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.4.3.9 | Columnrsw1000bvalueFactoryDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| 1.3.6.1.4.1.1166.6.1.2.18.4.3.10 | Columnrsw1000bstateflagFactoryDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.18.4.3.11 | Columnrsw1000blabelRFDataCRC | read-only | optional | The value of this object provides the label of the Radio Frequency Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.4.3.12 | Columnrsw1000bvalueRFDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| 1.3.6.1.4.1.1166.6.1.2.18.4.3.13 | Columnrsw1000bstateflagRFDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.18.4.3.14 | Columnrsw1000blabelAlarmDataCRC | read-only | optional | The value of this object provides the label of the Alarm Data Crc parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.4.3.15 | Columnrsw1000bvalueAlarmDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| 1.3.6.1.4.1.1166.6.1.2.18.4.3.16 | Columnrsw1000bstateflagAlarmDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.18.4.3.17 | Columnrsw1000blabelRFSignalStatus | read-only | optional | The value of this object provides the label of the RF Signal Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.4.3.18 | Columnrsw1000bvalueRFSignalStatus | read-only | mandatory | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| 1.3.6.1.4.1.1166.6.1.2.18.4.3.19 | Columnrsw1000bstateflagRFSignalStatus | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.18.4.3.20 | Columnrsw1000blabelPriActiveStatus | read-only | optional | The value of this object provides the label of the Secondary Active Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.18.4.3.21 | Columnrsw1000bvaluePriActiveStatus | read-only | mandatory | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| 1.3.6.1.4.1.1166.6.1.2.18.4.3.22 | Columnrsw1000bstateflagPriActiveStatus | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.18.5 | Tablegx2Rsw1000bFactoryTable | not-accessible | mandatory | This table contains gx2Rsw1000b specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.18.5 | NodetrapRSW1000bModuleTempAlarm | This trap is issued when the Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.18.5.4 | Rowgx2Rsw1000bFactoryEntry | not-accessible | mandatory | This list contains Factory parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.18.5.4.1 | Columngx2Rsw1000bFactoryTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.18.5.4.2 | Columnrsw1000bbootControlByte | read-only | mandatory | The value of this object indicates which bank the firmware is currently being boot from. |
| 1.3.6.1.4.1.1166.6.1.2.18.5.4.3 | Columnrsw1000bbootStatusByte | read-only | mandatory | This object indicates the status of the last boot |
| 1.3.6.1.4.1.1166.6.1.2.18.5.4.4 | Columnrsw1000bbank0CRC | read-only | mandatory | This object provides the CRC code of bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.18.5.4.5 | Columnrsw1000bbank1CRC | read-only | mandatory | This object provides the CRC code of bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.18.5.4.6 | Columnrsw1000bprgEEPROMByte | read-only | mandatory | This object indicates if the EEPROM has been programmed |
| 1.3.6.1.4.1.1166.6.1.2.18.5.4.7 | Columnrsw1000bfactoryCRC | read-only | mandatory | This object provides the CRC code for the Factory data. |
| 1.3.6.1.4.1.1166.6.1.2.18.5.4.8 | Columnrsw1000bcalculateCRC | read-only | mandatory | This oject indicates which of the Emnums will have the CRC calculated. |
| 1.3.6.1.4.1.1166.6.1.2.18.5.4.9 | Columnrsw1000bhourMeter | read-only | mandatory | This object provides the hour meter reading of the module. |
| 1.3.6.1.4.1.1166.6.1.2.18.5.4.10 | Columnrsw1000bflashPrgCnt0 | read-only | mandatory | This object provides the number of times Bank 1 flash has been programmed. |
| 1.3.6.1.4.1.1166.6.1.2.18.5.4.11 | Columnrsw1000bflashPrgCnt1 | read-only | mandatory | This object provides the number of times Bank 1 flash has been programmed. |
| 1.3.6.1.4.1.1166.6.1.2.18.5.4.12 | Columnrsw1000bflashBank0Rev | read-only | mandatory | This object provides the revision of flash bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.18.5.4.13 | Columnrsw1000bflashBank1Rev | read-only | mandatory | This object provides the revision of flash bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.18.5.4.14 | Columnrsw1000bSubagentRev | read-only | mandatory | This object provides the revision of the subagent. |
| 1.3.6.1.4.1.1166.6.1.2.18.6 | Tablegx2Rsw1000bHoldTimeTable | not-accessible | mandatory | This table contains gx2Rsw1000b specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.18.6 | NodetrapRSW1000bFlashAlarm | This trap is issued when the detects an error during Flash memory operations. | ||
| 1.3.6.1.4.1.1166.6.1.2.18.6.5 | Rowgx2Rsw1000bHoldTimeEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.18.6.5.1 | Columnrxgx2Rsw1000bHoldTimeTableIndex | read-only | mandatory | The value of this object is the index of the data object. |
| 1.3.6.1.4.1.1166.6.1.2.18.6.5.2 | Columnrxgx2Rsw1000bHoldTimeSpecIndex | read-only | mandatory | The value of this object identifies the index of the alarm object to be modified. |
| 1.3.6.1.4.1.1166.6.1.2.18.6.5.3 | Columnrxgx2Rsw1000bHoldTimeData | read-write | mandatory | The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered… |
| 1.3.6.1.4.1.1166.6.1.2.18.7 | NodetrapRSW1000bBankBootAlarm | This trap is issued when the detects an error while booting from bank 0 or bank 1. | ||
| 1.3.6.1.4.1.1166.6.1.2.18.8 | NodetrapRSW1000bAlarmDataCRCAlarm | This trap is issued when the Alarm Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.18.9 | NodetrapRSW1000bFactoryDataCRCAlarm | This trap is issued when the Factory Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.18.10 | NodetrapRSW1000bInputSwitchedAlarm | This trap is issued when the RF input switched. | ||
| 1.3.6.1.4.1.1166.6.1.2.18.11 | NodetrapRSW1000bResetFactoryDefaultAlarm | This trap is issued when the Factory Default Reset occurs. | ||
| 1.3.6.1.4.1.1166.6.1.2.18.12 | NodetrapRSW1000bSecondaryInputActiveAlarm | This trap is issued when the scondary input becomes active. | ||
| 1.3.6.1.4.1.1166.6.1.2.18.13 | NodetrapRSW1000bCalibrationDataCRCAlarm | This trap is issued when the calibration data CRC is incorrect. |