MIB Viewer

OMNI-gx2RSW1000B-MIB

167 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.1166.6.1.2.18.1Nodegx2Rsw1000bDescriptor
1.3.6.1.4.1.1166.6.1.2.18.1NodetrapRSW1000bConfigChangeIntegerThis trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre…
1.3.6.1.4.1.1166.6.1.2.18.2Tablegx2Rsw1000bAnalogTablenot-accessiblemandatoryThis table contains gx2Rsw1000b specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.18.2NodetrapRSW1000bConfigChangeDisplayStringThis trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may …
1.3.6.1.4.1.1166.6.1.2.18.2.1Rowgx2Rsw1000bAnalogEntrynot-accessiblemandatoryThis list contains the analog parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.18.2.1.1Columngx2Rsw1000bAnalogTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.18.2.1.2Columnrsw1000blabelPriRFInputLvlread-onlyoptionalThe value of this object provides the label of the Primary RF Input Level Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.3Columnrsw1000buomPriRFInputLvlread-onlyoptionalThe value of this object provides the Unit of Measure of the Primary RF Input Level Analog parameter. For all analog objects for this parameter type, the Unit …
1.3.6.1.4.1.1166.6.1.2.18.2.1.4Columnrsw1000bmajorHighPriRFInputLvlread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object…
1.3.6.1.4.1.1166.6.1.2.18.2.1.5Columnrsw1000bmajorLowPriRFInputLvlread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object…
1.3.6.1.4.1.1166.6.1.2.18.2.1.6Columnrsw1000bminorHighPriRFInputLvlread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object…
1.3.6.1.4.1.1166.6.1.2.18.2.1.7Columnrsw1000bminorLowPriRFInputLvlread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object…
1.3.6.1.4.1.1166.6.1.2.18.2.1.8Columnrsw1000bcurrentValuePriRFInputLvlread-onlymandatoryThe value of this object provides the current value of the Primary RF Input Level Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.9Columnrsw1000bstateFlagPriRFInputLvlread-onlymandatoryThe value of this object provides the state of the Primary RF Input Level Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.18.2.1.10Columnrsw1000bminValuePriRFInputLvlread-onlymandatoryThe value of this object represents a gauge minimum limit for the Primary RF Input Level Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.11Columnrsw1000bmaxValuePriRFInputLvlread-onlymandatoryThe value of this object represents a gauge maximum limit for the Primary RF Input Level Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.12Columnrsw1000balarmStatePriRFInputLvlread-onlymandatoryThe value of this object provides the curent alarm state of the Primary RF Input Level Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.13Columnrsw1000blabelSecRFInputLvlread-onlyoptionalThe value of this object provides the label of the Secondary RF Input Level Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.14Columnrsw1000buomSecRFInputLvlread-onlyoptionalThe value of this object provides the Unit of Measure of the Secondary RF Input Level Analog parameter. For all analog objects for this parameter type, the Uni…
1.3.6.1.4.1.1166.6.1.2.18.2.1.15Columnrsw1000bmajorHighSecRFInputLvlread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object…
1.3.6.1.4.1.1166.6.1.2.18.2.1.16Columnrsw1000bmajorLowSecRFInputLvlread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object…
1.3.6.1.4.1.1166.6.1.2.18.2.1.17Columnrsw1000bminorHighSecRFInputLvlread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object…
1.3.6.1.4.1.1166.6.1.2.18.2.1.18Columnrsw1000bminorLowSecRFInputLvlread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object…
1.3.6.1.4.1.1166.6.1.2.18.2.1.19Columnrsw1000bcurrentValueSecRFInputLvlread-onlymandatoryThe value of this object provides the current value of the Secondary RF Input Level Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.20Columnrsw1000bstateFlagSecRFInputLvlread-onlymandatoryThe value of this object provides the state of the Secondary RF Input Level Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.18.2.1.21Columnrsw1000bminValueSecRFInputLvlread-onlymandatoryThe value of this object represents a gauge minimum limit for the Secondary RF Input Level Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.22Columnrsw1000bmaxValueSecRFInputLvlread-onlymandatoryThe value of this object represents a gauge maximum limit for the Secondary RF Input Level Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.23Columnrsw1000balarmStateSecRFInputLvlread-onlymandatoryThe value of this object provides the curent alarm state of the Secondary RF Input Level Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.24Columnrsw1000blabelPriRFThresholdread-onlyoptionalThe value of this object provides the label of the Primary RF Threshold Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.25Columnrsw1000buomPriRFThresholdread-onlyoptionalThe value of this object provides the Unit of Measure of the Primary RF Threshold Analog parameter. For all analog objects for this parameter type, the Unit of…
1.3.6.1.4.1.1166.6.1.2.18.2.1.26Columnrsw1000bmajorHighPriRFThresholdread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object…
1.3.6.1.4.1.1166.6.1.2.18.2.1.27Columnrsw1000bmajorLowPriRFThresholdread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object…
1.3.6.1.4.1.1166.6.1.2.18.2.1.28Columnrsw1000bminorHighPriRFThresholdread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object…
1.3.6.1.4.1.1166.6.1.2.18.2.1.29Columnrsw1000bminorLowPriRFThresholdread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object…
1.3.6.1.4.1.1166.6.1.2.18.2.1.30Columnrsw1000bcurrentValuePriRFThresholdread-writemandatoryThe value of this object provides the current value of the Primary RF Threshold Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.31Columnrsw1000bstateFlagPriRFThresholdread-onlymandatoryThe value of this object provides the state of the Primary RF Threshold Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.18.2.1.32Columnrsw1000bminValuePriRFThresholdread-onlymandatoryThe value of this object represents a gauge minimum limit for the Primary RF Threshold Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.33Columnrsw1000bmaxValuePriRFThresholdread-onlymandatoryThe value of this object represents a gauge maximum limit for the Primary RF Threshold Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.34Columnrsw1000balarmStatePriRFThresholdread-onlymandatoryThe value of this object provides the curent alarm state of the Primary RF Threshold Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.35Columnrsw1000blabelSecRFThresholdread-onlyoptionalThe value of this object provides the label of the Secondary RF Threshold Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.36Columnrsw1000buomSecRFThresholdread-onlyoptionalThe value of this object provides the Unit of Measure of the Secondary RF Threshold Analog parameter. For all analog objects for this parameter type, the Unit …
1.3.6.1.4.1.1166.6.1.2.18.2.1.37Columnrsw1000bmajorHighSecRFThresholdread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object…
1.3.6.1.4.1.1166.6.1.2.18.2.1.38Columnrsw1000bmajorLowSecRFThresholdread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object…
1.3.6.1.4.1.1166.6.1.2.18.2.1.39Columnrsw1000bminorHighSecRFThresholdread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object…
1.3.6.1.4.1.1166.6.1.2.18.2.1.40Columnrsw1000bminorLowSecRFThresholdread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object…
1.3.6.1.4.1.1166.6.1.2.18.2.1.41Columnrsw1000bcurrentValueSecRFThresholdread-writemandatoryThe value of this object provides the current value of the Secondary RF Threshold Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.42Columnrsw1000bstateFlagSecRFThresholdread-onlymandatoryThe value of this object provides the state of the Secondary RF Threshold Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.18.2.1.43Columnrsw1000bminValueSecRFThresholdread-onlymandatoryThe value of this object represents a gauge minimum limit for the Secondary RF Threshold Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.44Columnrsw1000bmaxValueSecRFThresholdread-onlymandatoryThe value of this object represents a gauge maximum limit for the Secondary RF Threshold Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.45Columnrsw1000balarmStateSecRFThresholdread-onlymandatoryThe value of this object provides the curent alarm state of the Secondary RF Threshold Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.46Columnrsw1000blabelModTempread-onlyoptionalThe value of this object provides the label of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.47Columnrsw1000buomModTempread-onlyoptionalThe value of this object provides the Unit of Measure of the Module Temperature Analog parameter. For all analog objects for this parameter type, the Unit of M…
1.3.6.1.4.1.1166.6.1.2.18.2.1.48Columnrsw1000bmajorHighModTempread-onlymandatoryThe value of this object provides the Major High alarm value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.49Columnrsw1000bmajorLowModTempread-onlymandatoryThe value of this object provides the Major Low alarm value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.50Columnrsw1000bminorHighModTempread-onlymandatoryThe value of this object provides the Minor High alarm value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.51Columnrsw1000bminorLowModTempread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.52Columnrsw1000bcurrentValueModTempread-onlymandatoryThe value of this object provides the Current value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.53Columnrsw1000bstateFlagModTempread-onlymandatoryThe value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.18.2.1.54Columnrsw1000bminValueModTempread-onlymandatoryThe value of this object represents a gauge minimum limit for the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.55Columnrsw1000bmaxValueModTempread-onlymandatoryThe value of this object represents a gauge maximum limit for the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.56Columnrsw1000balarmStateModTempread-onlymandatoryThe value of this object provides the curent alarm state of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.57Columnrsw1000blabelFanCurrentread-onlyoptionalThe value of this object provides the label of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.58Columnrsw1000buomFanCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the Fan Current Analog parameter. For all analog objects for this parameter type, the Unit of Measure …
1.3.6.1.4.1.1166.6.1.2.18.2.1.59Columnrsw1000bmajorHighFanCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.60Columnrsw1000bmajorLowFanCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.61Columnrsw1000bminorHighFanCurrentread-onlyobsoleteThis object is not used by this module and always returns invalid floating point value of 0xFFFFFFFF. This object is kept here for persistence. The value of th…
1.3.6.1.4.1.1166.6.1.2.18.2.1.62Columnrsw1000bminorLowFanCurrentread-onlyobsoleteThis object is not used by this module and always returns invalid floating point value of 0xFFFFFFFF. This object is kept here for persistence. The value of th…
1.3.6.1.4.1.1166.6.1.2.18.2.1.63Columnrsw1000bcurrentValueFanCurrentread-onlymandatoryThe value of this object provides the Current value of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.64Columnrsw1000bstateFlagFanCurrentread-onlymandatoryThe value of this object provides the state of the Fan Current Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.18.2.1.65Columnrsw1000bminValueFanCurrentread-onlymandatoryThe value of this object represents a gauge minimum limit for the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.66Columnrsw1000bmaxValueFanCurrentread-onlymandatoryThe value of this object represents a gauge maximum limit for the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.2.1.67Columnrsw1000balarmStateFanCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.18.3Tablegx2Rsw1000bDigitalTablenot-accessiblemandatoryThis table contains gx2Rsw1000b specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.18.3NodetrapRSW1000bRFInputAlarmThis trap is issued when the Switch Control signals go out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.18.3.2Rowgx2Rsw1000bDigitalEntrynot-accessiblemandatoryThis list contains digital parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.18.3.2.1Columngx2Rsw1000bDigitalTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.18.3.2.2Columnrsw1000blabelSwitchControlread-onlyoptionalThe value of this object provides the label of the Switch Control Digital parameter.
1.3.6.1.4.1.1166.6.1.2.18.3.2.3Columnrsw1000benumSwitchControlread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.18.3.2.4Columnrsw1000bvalueSwitchControlread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.18.3.2.5Columnrsw1000bstateflagSwitchControlread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.18.3.2.6Columnrsw1000blabelSwitchModeread-onlyoptionalThe value of this object provides the label of the Revert Mode Digital parameter.
1.3.6.1.4.1.1166.6.1.2.18.3.2.7Columnrsw1000benumSwitchModeread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.18.3.2.8Columnrsw1000bvalueSwitchModeread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.18.3.2.9Columnrsw1000bstateflagSwitchModeread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.18.3.2.10Columnrsw1000blabelRevertEnableread-onlyoptionalThe value of this object provides the label of the Revert Enable Digital parameter.
1.3.6.1.4.1.1166.6.1.2.18.3.2.11Columnrsw1000benumRevertEnableread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.18.3.2.12Columnrsw1000bvalueRevertEnableread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.18.3.2.13Columnrsw1000bstateflagRevertEnableread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.18.3.2.14Columnrsw1000blabelRevertTimeread-onlyoptionalThe value of this object provides the label of the Revert Time Digital parameter.
1.3.6.1.4.1.1166.6.1.2.18.3.2.15Columnrsw1000benumRevertTimeread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.18.3.2.16Columnrsw1000bvalueRevertTimeread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.18.3.2.17Columnrsw1000bstateflagRevertTimeread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.18.3.2.18Columnrsw1000blabelSensorModeread-onlyoptionalThe value of this object provides the label of the SensorMode Digital parameter.
1.3.6.1.4.1.1166.6.1.2.18.3.2.19Columnrsw1000benumSensorModeread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.18.3.2.20Columnrsw1000bvalueSensorModeread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.18.3.2.21Columnrsw1000bstateflagSensorModeread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.18.3.2.22Columnrsw1000blabelSwitchMonitorread-onlyoptionalThe value of this object provides the label of the Switch Monitor Digital parameter.
1.3.6.1.4.1.1166.6.1.2.18.3.2.23Columnrsw1000benumSwitchMonitorread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.18.3.2.24Columnrsw1000bvalueSwitchMonitorread-onlymandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.18.3.2.25Columnrsw1000bstateflagSwitchMonitorread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.18.3.2.26Columnrsw1000blabelPriStatusSigread-onlyoptionalThe value of this object provides the label of the Primary Control Signal Digital parameter.
1.3.6.1.4.1.1166.6.1.2.18.3.2.27Columnrsw1000benumPriStatusSigread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.18.3.2.28Columnrsw1000bvaluePriStatusSigread-onlymandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.18.3.2.29Columnrsw1000bstateflagPriStatusSigread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.18.3.2.30Columnrsw1000blabelSecStatusSigread-onlyoptionalThe value of this object provides the label of the Secondary Control Signal Digital parameter.
1.3.6.1.4.1.1166.6.1.2.18.3.2.31Columnrsw1000benumSecStatusSigread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.18.3.2.32Columnrsw1000bvalueSecStatusSigread-onlymandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.18.3.2.33Columnrsw1000bstateflagSecStatusSigread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.18.3.2.34Columnrsw1000blabelFactoryDefaultread-onlyoptionalThe value of this object provides the label of the Factory Default Reset Digital parameter.
1.3.6.1.4.1.1166.6.1.2.18.3.2.35Columnrsw1000benumFactoryDefaultread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.18.3.2.36Columnrsw1000bvalueFactoryDefaultread-writemandatoryThis is a one-shot control value. A read of this value is always the value corresponding to off(1). A write of the value corresponding to on(2) results in effe…
1.3.6.1.4.1.1166.6.1.2.18.3.2.37Columnrsw1000bstateflagFactoryDefaultread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.18.4Tablegx2Rsw1000bStatusTablenot-accessiblemandatoryThis table contains gx2Rsw1000b specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.18.4NodetrapRSW1000bFanCurrentAlarmThis trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.18.4.3Rowgx2Rsw1000bStatusEntrynot-accessiblemandatoryThis list contains Status parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.18.4.3.1Columngx2Rsw1000bStatusTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.18.4.3.2Columnrsw1000blabelBootread-onlyoptionalThe value of this object provides the label of the Boot Status Status parameter.
1.3.6.1.4.1.1166.6.1.2.18.4.3.3Columnrsw1000bvalueBootread-onlymandatoryThe value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
1.3.6.1.4.1.1166.6.1.2.18.4.3.4Columnrsw1000bstateflagBootread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.18.4.3.5Columnrsw1000blabelFlashread-onlyoptionalThe value of this object provides the label of the Flash Status Status parameter.
1.3.6.1.4.1.1166.6.1.2.18.4.3.6Columnrsw1000bvalueFlashread-onlymandatoryThe value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
1.3.6.1.4.1.1166.6.1.2.18.4.3.7Columnrsw1000bstateflagFlashread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.18.4.3.8Columnrsw1000blabelFactoryDataCRCread-onlyoptionalThe value of this object provides the label of the Factory Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.18.4.3.9Columnrsw1000bvalueFactoryDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
1.3.6.1.4.1.1166.6.1.2.18.4.3.10Columnrsw1000bstateflagFactoryDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.18.4.3.11Columnrsw1000blabelRFDataCRCread-onlyoptionalThe value of this object provides the label of the Radio Frequency Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.18.4.3.12Columnrsw1000bvalueRFDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
1.3.6.1.4.1.1166.6.1.2.18.4.3.13Columnrsw1000bstateflagRFDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.18.4.3.14Columnrsw1000blabelAlarmDataCRCread-onlyoptionalThe value of this object provides the label of the Alarm Data Crc parameter.
1.3.6.1.4.1.1166.6.1.2.18.4.3.15Columnrsw1000bvalueAlarmDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
1.3.6.1.4.1.1166.6.1.2.18.4.3.16Columnrsw1000bstateflagAlarmDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.18.4.3.17Columnrsw1000blabelRFSignalStatusread-onlyoptionalThe value of this object provides the label of the RF Signal Status parameter.
1.3.6.1.4.1.1166.6.1.2.18.4.3.18Columnrsw1000bvalueRFSignalStatusread-onlymandatoryThe value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
1.3.6.1.4.1.1166.6.1.2.18.4.3.19Columnrsw1000bstateflagRFSignalStatusread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.18.4.3.20Columnrsw1000blabelPriActiveStatusread-onlyoptionalThe value of this object provides the label of the Secondary Active Status parameter.
1.3.6.1.4.1.1166.6.1.2.18.4.3.21Columnrsw1000bvaluePriActiveStatusread-onlymandatoryThe value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
1.3.6.1.4.1.1166.6.1.2.18.4.3.22Columnrsw1000bstateflagPriActiveStatusread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.18.5Tablegx2Rsw1000bFactoryTablenot-accessiblemandatoryThis table contains gx2Rsw1000b specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.18.5NodetrapRSW1000bModuleTempAlarmThis trap is issued when the Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.18.5.4Rowgx2Rsw1000bFactoryEntrynot-accessiblemandatoryThis list contains Factory parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.18.5.4.1Columngx2Rsw1000bFactoryTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.18.5.4.2Columnrsw1000bbootControlByteread-onlymandatoryThe value of this object indicates which bank the firmware is currently being boot from.
1.3.6.1.4.1.1166.6.1.2.18.5.4.3Columnrsw1000bbootStatusByteread-onlymandatoryThis object indicates the status of the last boot
1.3.6.1.4.1.1166.6.1.2.18.5.4.4Columnrsw1000bbank0CRCread-onlymandatoryThis object provides the CRC code of bank 0.
1.3.6.1.4.1.1166.6.1.2.18.5.4.5Columnrsw1000bbank1CRCread-onlymandatoryThis object provides the CRC code of bank 1.
1.3.6.1.4.1.1166.6.1.2.18.5.4.6Columnrsw1000bprgEEPROMByteread-onlymandatoryThis object indicates if the EEPROM has been programmed
1.3.6.1.4.1.1166.6.1.2.18.5.4.7Columnrsw1000bfactoryCRCread-onlymandatoryThis object provides the CRC code for the Factory data.
1.3.6.1.4.1.1166.6.1.2.18.5.4.8Columnrsw1000bcalculateCRCread-onlymandatoryThis oject indicates which of the Emnums will have the CRC calculated.
1.3.6.1.4.1.1166.6.1.2.18.5.4.9Columnrsw1000bhourMeterread-onlymandatoryThis object provides the hour meter reading of the module.
1.3.6.1.4.1.1166.6.1.2.18.5.4.10Columnrsw1000bflashPrgCnt0read-onlymandatoryThis object provides the number of times Bank 1 flash has been programmed.
1.3.6.1.4.1.1166.6.1.2.18.5.4.11Columnrsw1000bflashPrgCnt1read-onlymandatoryThis object provides the number of times Bank 1 flash has been programmed.
1.3.6.1.4.1.1166.6.1.2.18.5.4.12Columnrsw1000bflashBank0Revread-onlymandatoryThis object provides the revision of flash bank 0.
1.3.6.1.4.1.1166.6.1.2.18.5.4.13Columnrsw1000bflashBank1Revread-onlymandatoryThis object provides the revision of flash bank 1.
1.3.6.1.4.1.1166.6.1.2.18.5.4.14Columnrsw1000bSubagentRevread-onlymandatoryThis object provides the revision of the subagent.
1.3.6.1.4.1.1166.6.1.2.18.6Tablegx2Rsw1000bHoldTimeTablenot-accessiblemandatoryThis table contains gx2Rsw1000b specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.18.6NodetrapRSW1000bFlashAlarmThis trap is issued when the detects an error during Flash memory operations.
1.3.6.1.4.1.1166.6.1.2.18.6.5Rowgx2Rsw1000bHoldTimeEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.18.6.5.1Columnrxgx2Rsw1000bHoldTimeTableIndexread-onlymandatoryThe value of this object is the index of the data object.
1.3.6.1.4.1.1166.6.1.2.18.6.5.2Columnrxgx2Rsw1000bHoldTimeSpecIndexread-onlymandatoryThe value of this object identifies the index of the alarm object to be modified.
1.3.6.1.4.1.1166.6.1.2.18.6.5.3Columnrxgx2Rsw1000bHoldTimeDataread-writemandatoryThe value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered…
1.3.6.1.4.1.1166.6.1.2.18.7NodetrapRSW1000bBankBootAlarmThis trap is issued when the detects an error while booting from bank 0 or bank 1.
1.3.6.1.4.1.1166.6.1.2.18.8NodetrapRSW1000bAlarmDataCRCAlarmThis trap is issued when the Alarm Data CRC is incorrect.
1.3.6.1.4.1.1166.6.1.2.18.9NodetrapRSW1000bFactoryDataCRCAlarmThis trap is issued when the Factory Data CRC is incorrect.
1.3.6.1.4.1.1166.6.1.2.18.10NodetrapRSW1000bInputSwitchedAlarmThis trap is issued when the RF input switched.
1.3.6.1.4.1.1166.6.1.2.18.11NodetrapRSW1000bResetFactoryDefaultAlarmThis trap is issued when the Factory Default Reset occurs.
1.3.6.1.4.1.1166.6.1.2.18.12NodetrapRSW1000bSecondaryInputActiveAlarmThis trap is issued when the scondary input becomes active.
1.3.6.1.4.1.1166.6.1.2.18.13NodetrapRSW1000bCalibrationDataCRCAlarmThis trap is issued when the calibration data CRC is incorrect.