OMNI-gx2drr2x-MIB
150 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.21.1 | Nodegx2drr2xDescriptor | |||
| 1.3.6.1.4.1.1166.6.1.2.21.1 | NodetrapdrrConfigChangeInteger | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre… | ||
| 1.3.6.1.4.1.1166.6.1.2.21.2 | Tablegx2drr2xAnalogTable | not-accessible | mandatory | This table contains gx2drr2x specific analog parameters with nominal,limits and current values. |
| 1.3.6.1.4.1.1166.6.1.2.21.2 | NodetrapdrrConfigChangeDisplayString | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may … | ||
| 1.3.6.1.4.1.1166.6.1.2.21.2.1 | Rowgx2drr2xAnalogEntry | not-accessible | mandatory | This list contains the analog parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.1 | Columngx2drr2xAnalogTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.2 | Columndrr2xlabelRFAAttenuation | read-only | optional | The value of this object provides the label of the RF Channel A Attenuation Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.3 | Columndrr2xuomRFAAttenuation | read-only | optional | The value of this object provides the Unit of Measure of the RF Channel A Attenuation Analog parameter. The unit is in dB |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.4 | Columndrr2xmajorHighRFAAttenuation | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.5 | Columndrr2xmajorLowRFAAttenuation | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.6 | Columndrr2xminorHighRFAAttenuation | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.7 | Columndrr2xminorLowRFAAttenuation | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.8 | Columndrr2xcurrentValueRFAAttenuation | read-write | mandatory | The value of this object provides the Current value of the RF Channel A Attenuation Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.9 | Columndrr2xstateFlagRFAAttenuation | read-only | mandatory | The value of this object provides the state of the RF Channel A Attenuation Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.10 | Columndrr2xminValueRFAAttenuation | read-only | mandatory | The value of this object provides the minimum value the RF Channel A Attenuation Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.11 | Columndrr2xmaxValueRFAAttenuation | read-only | mandatory | The value of this object provides the maximum value the RF Channel A Attenuation Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.12 | Columndrr2xalarmStateRFAAttenuation | read-only | mandatory | The value of this object provides the curent alarm state of the RF Channel A Attenuation Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.13 | Columndrr2xlabelRFBAttenuation | read-only | optional | The value of this object provides the label of the RF Channel B Attenuation Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.14 | Columndrr2xuomRFBAttenuation | read-only | optional | The value of this object provides the Unit of Measure of the RF Channel B Attenuation Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.15 | Columndrr2xmajorHighRFBAttenuation | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.16 | Columndrr2xmajorLowRFBAttenuation | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.17 | Columndrr2xminorHighRFBAttenuation | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.18 | Columndrr2xminorLowRFBAttenuation | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. It is kept here for persistence. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.19 | Columndrr2xcurrentValueRFBAttenuation | read-write | mandatory | The value of this object provides the Current value of the RF Channel B Attenuation Analog parameter. The unit is dB |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.20 | Columndrr2xstateFlagRFBAttenuation | read-only | mandatory | The value of this object provides the state of the RF Channel B Attenuation Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.21 | Columndrr2xminValueRFBAttenuation | read-only | mandatory | The value of this object provides the minimum value the RF Channel B Attenuation Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.22 | Columndrr2xmaxValueRFBAttenuation | read-only | mandatory | The value of this object provides the maximum value the RF Channel B Attenuation Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.23 | Columndrr2xalarmStateRFBAttenuation | read-only | mandatory | The value of this object provides the curent alarm state of the RF Channel B Attenuation Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.24 | Columndrr2xlabelTrippointLevel | read-only | optional | The value of this object provides the label of the trip point level Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.25 | Columndrr2xuomTrippointLevel | read-only | optional | The value of this object provides the Unit of Measure of the trip point level Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.26 | Columndrr2xmajorHighTrippointLevel | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.27 | Columndrr2xmajorLowTrippointLevel | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.28 | Columndrr2xminorHighTrippointLevel | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.29 | Columndrr2xminorLowTrippointLevel | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.30 | Columndrr2xcurrentValueTrippointLevel | read-write | mandatory | The value of this object provides the Current value of the trip point level Analog parameter. The trip point level set the custumer preferred optical input lev… |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.31 | Columndrr2xstateFlagTrippointLevel | read-only | mandatory | The value of this object provides the state of the trip point level Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.32 | Columndrr2xminValueTrippointLevel | read-only | mandatory | The value of this object provides the minimum value the trip point level Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.33 | Columndrr2xmaxValueTrippointLevel | read-only | mandatory | The value of this object provides the maximum value the trip point level Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.34 | Columndrr2xalarmStateTrippointLevel | read-only | mandatory | The value of this object provides the curent alarm state of the trip point level Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.35 | Columndrr2xlabelOptCurrent | read-only | optional | The value of this object provides the label of the Optical Power Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.36 | Columndrr2xuomOptCurrent | read-only | optional | The value of this object provides the Unit of Measure of the Optical Power Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.37 | Columndrr2xmajorHighOptCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the Optical Power Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.38 | Columndrr2xmajorLowOptCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the Optical Power Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.39 | Columndrr2xminorHighOptCurrent | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.40 | Columndrr2xminorLowOptCurrent | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.41 | Columndrr2xcurrentValueOptCurrent | read-only | mandatory | The value of this object provides the Current value of the Optical Power Current Analog parameter. The input optical power in lower than min value, drr2xcurren… |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.42 | Columndrr2xstateFlagOptCurrent | read-only | mandatory | The value of this object provides the state of the Optical Power Current Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.43 | Columndrr2xminValueOptCurrent | read-only | mandatory | This is recommended min range for display gauge |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.44 | Columndrr2xmaxValueOptCurrent | read-only | mandatory | This is recommended max range for display gauge |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.45 | Columndrr2xalarmStateOptCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the Optical Power Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.46 | Columndrr2xlabel12VCurrent | read-only | optional | The value of this object provides the label of the 12v power supply Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.47 | Columndrr2xuom12VCurrent | read-only | optional | The value of this object provides the Unit of Measure of the 12v power supply Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.48 | Columndrr2xmajorHigh12VCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the 12v power supply Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.49 | Columndrr2xmajorLow12VCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the 12v power supply Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.50 | Columndrr2xminorHigh12VCurrent | read-only | mandatory | The value of this object provides the Minor High alarm value of the 12v power supply Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.51 | Columndrr2xminorLow12VCurrent | read-only | mandatory | The value of this object provides the Minor Low alarm value of the 12v power supply Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.52 | Columndrr2xcurrentValue12VCurrent | read-only | mandatory | The value of this object provides the Current value of the 12v power supply Current parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.53 | Columndrr2xstateFlag12VCurrent | read-only | mandatory | The value of this object provides the state of the 12v power supply Current Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.54 | Columndrr2xminValue12VCurrent | read-only | mandatory | The value of this object provides the minimum value the 12v power supply Current Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.55 | Columndrr2xmaxValue12VCurrent | read-only | mandatory | The value of this object provides the maximum value the 12v power supply Current Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.56 | Columndrr2xalarmState12VCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the 12v power supply Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.57 | Columndrr2xlabelModTemp | read-only | optional | The value of this object provides the label of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.58 | Columndrr2xuomModTemp | read-only | optional | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.59 | Columndrr2xmajorHighModTemp | read-only | mandatory | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.60 | Columndrr2xmajorLowModTemp | read-only | mandatory | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.61 | Columndrr2xminorHighModTemp | read-only | mandatory | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.62 | Columndrr2xminorLowModTemp | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.63 | Columndrr2xcurrentValueModTemp | read-only | mandatory | The value of this object provides the Current value of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.64 | Columndrr2xstateFlagModTemp | read-only | mandatory | The value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.65 | Columndrr2xminValueModTemp | read-only | mandatory | The value of this object provides the minimum value the Module Temperature Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.66 | Columndrr2xmaxValueModTemp | read-only | mandatory | The value of this object provides the maximum value the Module Temperature Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.67 | Columndrr2xalarmStateModTemp | read-only | mandatory | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.68 | Columndrr2xlabelFanCurrent | read-only | optional | The value of this object provides the label of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.69 | Columndrr2xuomFanCurrent | read-only | optional | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.70 | Columndrr2xmajorHighFanCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.71 | Columndrr2xmajorLowFanCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.72 | Columndrr2xminorHighFanCurrent | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.73 | Columndrr2xminorLowFanCurrent | read-only | obsolete | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.74 | Columndrr2xcurrentValueFanCurrent | read-only | mandatory | The value of this object provides the Current value of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.75 | Columndrr2xstateFlagFanCurrent | read-only | mandatory | The value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.76 | Columndrr2xminValueFanCurrent | read-only | mandatory | The value of this object provides the minimum value the Fan Current Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.77 | Columndrr2xmaxValueFanCurrent | read-only | mandatory | The value of this object provides the maximum value the Fan Current Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.21.2.1.78 | Columndrr2xalarmStateFanCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.3 | Tablegx2drr2xDigitalTable | not-accessible | mandatory | This table contains gx2drr2x specific digital parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.21.3 | Nodetrapdrr12VCurrentAlarm | This trap is issued when the 12V power supply Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this para… | ||
| 1.3.6.1.4.1.1166.6.1.2.21.3.2 | Rowgx2drr2xDigitalEntry | not-accessible | mandatory | This list contains individual digital parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.21.3.2.1 | Columngx2drr2xDigitalTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.21.3.2.2 | Columndrr2xlabelTrippointMode | read-only | optional | The value of this object provides the label of the Trip point mode Digital parameter. The trip point mode defines the RF switch action based on the optical pow… |
| 1.3.6.1.4.1.1166.6.1.2.21.3.2.3 | Columndrr2xenumTrippointMode | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. |
| 1.3.6.1.4.1.1166.6.1.2.21.3.2.4 | Columndrr2xvalueTrippointMode | read-write | mandatory | The value of this object is the current value of trip point mode. There are three possible value: 1-off, 2-alarm_only, 3-alarm&switch. If module input optical … |
| 1.3.6.1.4.1.1166.6.1.2.21.3.2.5 | Columndrr2xstateflagTrippointMode | read-only | mandatory | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.21.3.2.6 | Columndrr2xlabelFactoryDefaultReset | read-only | optional | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.3.2.7 | Columndrr2xenumFactoryDefaultReset | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.21.3.2.8 | Columndrr2xvalueFactoryDefaultReset | read-write | mandatory | The read of this value will return a invalid value. The read will not reflect the actual setting value for this parameter |
| 1.3.6.1.4.1.1166.6.1.2.21.3.2.9 | Columndrr2xstateflagFactoryDefaultReset | read-only | mandatory | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.21.4 | Tablegx2drr2xStatusTable | not-accessible | mandatory | This table contains gx2drr2x specific status parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.21.4 | NodetrapdrrModuleTempAlarm | This trap is issued when the Internal Module Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.21.4.3 | Rowgx2drr2xStatusEntry | not-accessible | mandatory | This list contains Status parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.21.4.3.1 | Columngx2drr2xStatusTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.21.4.3.2 | Columndrr2xlabelBoot | read-only | optional | The value of this object provides the label of the Boot Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.4.3.3 | Columndrr2xvalueBoot | read-only | mandatory | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.21.4.3.4 | Columndrr2xstateflagBoot | read-only | mandatory | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.21.4.3.5 | Columndrr2xlabelFlash | read-only | optional | The value of this object provides the label of the Flash Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.4.3.6 | Columndrr2xvalueFlash | read-only | mandatory | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.21.4.3.7 | Columndrr2xstateflagFlash | read-only | mandatory | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.21.4.3.8 | Columndrr2xlabelFactoryDataCRC | read-only | optional | The value of this object provides the label of the Factory Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.4.3.9 | Columndrr2xvalueFactoryDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.21.4.3.10 | Columndrr2xstateflagFactoryDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.21.4.3.11 | Columndrr2xlabelAlarmDataCrc | read-only | optional | The value of this object provides the label of the Alarm Data Crc parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.4.3.12 | Columndrr2xvalueAlarmDataCrc | read-only | mandatory | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.21.4.3.13 | Columndrr2xstateflagAlarmDataCrc | read-only | mandatory | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.21.4.3.14 | Columndrr2xlabelCalibrationDataCrc | read-only | optional | The value of this object provides the label of the Calibration Data Crc parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.4.3.15 | Columndrr2xvalueCalibrationDataCrc | read-only | mandatory | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.21.4.3.16 | Columndrr2xstateflagCalibrationDataCrc | read-only | mandatory | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.21.4.3.17 | Columndrr2xlabelHardwareStatus | read-only | optional | The value of this object provides the label of the Module Hardware Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.21.4.3.18 | Columndrr2xvalueHardwareStatus | read-only | mandatory | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.21.4.3.19 | Columndrr2xstateflagHardwareStatus | read-only | mandatory | The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.21.4.3.20 | Columndrr2xlabelOpticTripPointStatus | read-only | optional | The value of this object provides the label of the Optical Trip Point Status parameter.It indicates whether the optical power is above(0) or below(1) trip poin… |
| 1.3.6.1.4.1.1166.6.1.2.21.4.3.21 | Columndrr2xvalueOpticTripPointStatus | read-only | mandatory | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.21.4.3.22 | Columndrr2xstateflagOpticTripPointStatus | read-only | mandatory | The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.21.4.3.23 | Columndrr2xlabelLinkStatus | read-only | optional | The value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect t… |
| 1.3.6.1.4.1.1166.6.1.2.21.4.3.24 | Columndrr2xvalueLinkStatus | read-only | mandatory | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.21.4.3.25 | Columndrr2xstateflagLinkStatus | read-only | mandatory | The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.21.5 | Tablegx2drr2xFactoryTable | not-accessible | mandatory | This table contains gx2drr2x specific factory setting parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.21.5 | NodetrapdrrFanCurrentAlarm | This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.21.5.4 | Rowgx2drr2xFactoryEntry | not-accessible | mandatory | This list contains Factory setting parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.21.5.4.1 | Columngx2drr2xFactoryTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.21.5.4.2 | Columndrr2xbootControlByte | read-only | mandatory | The value of this object indicates which bank the firmware is currently being boot from. |
| 1.3.6.1.4.1.1166.6.1.2.21.5.4.3 | Columndrr2xbootStatusByte | read-only | mandatory | This object indicates the status of the last boot |
| 1.3.6.1.4.1.1166.6.1.2.21.5.4.4 | Columndrr2xbank1CRC | read-only | mandatory | This object provides the CRC code of bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.21.5.4.5 | Columndrr2xbank2CRC | read-only | mandatory | This object provides the CRC code of bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.21.5.4.6 | Columndrr2xprgEEPROMByte | read-only | mandatory | This object indicates if the EEPROM has been programmed |
| 1.3.6.1.4.1.1166.6.1.2.21.5.4.7 | Columndrr2xfactoryCRC | read-only | mandatory | This object provides the CRC code for the Factory data. |
| 1.3.6.1.4.1.1166.6.1.2.21.5.4.8 | Columndrr2xcalculateCRC | read-only | mandatory | This object indicates which of the Emnums will have the CRC calculated (1-factory, 2-alarm, 3-calibration). |
| 1.3.6.1.4.1.1166.6.1.2.21.5.4.9 | Columndrr2xhourMeter | read-only | mandatory | This object provides the hour meter reading of the module. |
| 1.3.6.1.4.1.1166.6.1.2.21.5.4.10 | Columndrr2xflashPrgCntA | read-only | mandatory | This object provides the number of times Bank 0 flash has been programmed. |
| 1.3.6.1.4.1.1166.6.1.2.21.5.4.11 | Columndrr2xflashPrgCntB | read-only | mandatory | This object provides the number of times Bank 1 flash has been programmed. |
| 1.3.6.1.4.1.1166.6.1.2.21.5.4.12 | Columndrr2xflashBankARev | read-only | mandatory | This object provides the revision of flash bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.21.5.4.13 | Columndrr2xflashBankBRev | read-only | mandatory | This object provides the revision of flash bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.21.5.4.14 | Columndrr2xSubAgentRev | read-only | mandatory | This object provides the subagent revision of receiver module. |
| 1.3.6.1.4.1.1166.6.1.2.21.6 | NodetrapdrrFlashAlarm | This trap is issued when the detects an error during Flash memory operations. | ||
| 1.3.6.1.4.1.1166.6.1.2.21.7 | NodetrapdrrBankBootAlarm | This trap is issued when the module detects an error while booting from bank 0 or bank 1. | ||
| 1.3.6.1.4.1.1166.6.1.2.21.8 | NodetrapdrrAlarmDataCRCAlarm | This trap is issued when the Alarm Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.21.9 | NodetrapdrrHardwareErrAlarm | This trap is issued when hardware is abnormal. | ||
| 1.3.6.1.4.1.1166.6.1.2.21.10 | NodetrapdrrOpticalSignalAlarm | This trap is issued when the optical signal is beyond the preset range. | ||
| 1.3.6.1.4.1.1166.6.1.2.21.11 | NodetrapdrrFactoryDataCRCAlarm | This trap is issued when the Factory Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.21.12 | NodetrapdrrResetFactoryDefaultAlarm | This trap is issued when the Factory Default Reset occurs. | ||
| 1.3.6.1.4.1.1166.6.1.2.21.13 | NodetrapdrrTripPointAlarm | This trap is issued when the Input optical power is lower than the custumer set trip point and trippoint mode as ALARM_ONLY or SWITCH & ALARM. | ||
| 1.3.6.1.4.1.1166.6.1.2.21.14 | NodetrapdrrLinkAlarm | This trap is issued when receiver is out of SYN with transmitter | ||
| 1.3.6.1.4.1.1166.6.1.2.21.15 | NodetrapdrrCalibrationDataCRCAlarm | This trap is issued when the Calibration Data CRC is incorrect |