MIB Viewer

OMNI-gx2drr2x-MIB

150 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.1166.6.1.2.21.1Nodegx2drr2xDescriptor
1.3.6.1.4.1.1166.6.1.2.21.1NodetrapdrrConfigChangeIntegerThis trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre…
1.3.6.1.4.1.1166.6.1.2.21.2Tablegx2drr2xAnalogTablenot-accessiblemandatoryThis table contains gx2drr2x specific analog parameters with nominal,limits and current values.
1.3.6.1.4.1.1166.6.1.2.21.2NodetrapdrrConfigChangeDisplayStringThis trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may …
1.3.6.1.4.1.1166.6.1.2.21.2.1Rowgx2drr2xAnalogEntrynot-accessiblemandatoryThis list contains the analog parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.21.2.1.1Columngx2drr2xAnalogTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.21.2.1.2Columndrr2xlabelRFAAttenuationread-onlyoptionalThe value of this object provides the label of the RF Channel A Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.3Columndrr2xuomRFAAttenuationread-onlyoptionalThe value of this object provides the Unit of Measure of the RF Channel A Attenuation Analog parameter. The unit is in dB
1.3.6.1.4.1.1166.6.1.2.21.2.1.4Columndrr2xmajorHighRFAAttenuationread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.21.2.1.5Columndrr2xmajorLowRFAAttenuationread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.21.2.1.6Columndrr2xminorHighRFAAttenuationread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.21.2.1.7Columndrr2xminorLowRFAAttenuationread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.21.2.1.8Columndrr2xcurrentValueRFAAttenuationread-writemandatoryThe value of this object provides the Current value of the RF Channel A Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.9Columndrr2xstateFlagRFAAttenuationread-onlymandatoryThe value of this object provides the state of the RF Channel A Attenuation Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.21.2.1.10Columndrr2xminValueRFAAttenuationread-onlymandatoryThe value of this object provides the minimum value the RF Channel A Attenuation Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.21.2.1.11Columndrr2xmaxValueRFAAttenuationread-onlymandatoryThe value of this object provides the maximum value the RF Channel A Attenuation Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.21.2.1.12Columndrr2xalarmStateRFAAttenuationread-onlymandatoryThe value of this object provides the curent alarm state of the RF Channel A Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.13Columndrr2xlabelRFBAttenuationread-onlyoptionalThe value of this object provides the label of the RF Channel B Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.14Columndrr2xuomRFBAttenuationread-onlyoptionalThe value of this object provides the Unit of Measure of the RF Channel B Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.15Columndrr2xmajorHighRFBAttenuationread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.21.2.1.16Columndrr2xmajorLowRFBAttenuationread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.21.2.1.17Columndrr2xminorHighRFBAttenuationread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.21.2.1.18Columndrr2xminorLowRFBAttenuationread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF. It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.21.2.1.19Columndrr2xcurrentValueRFBAttenuationread-writemandatoryThe value of this object provides the Current value of the RF Channel B Attenuation Analog parameter. The unit is dB
1.3.6.1.4.1.1166.6.1.2.21.2.1.20Columndrr2xstateFlagRFBAttenuationread-onlymandatoryThe value of this object provides the state of the RF Channel B Attenuation Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.21.2.1.21Columndrr2xminValueRFBAttenuationread-onlymandatoryThe value of this object provides the minimum value the RF Channel B Attenuation Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.21.2.1.22Columndrr2xmaxValueRFBAttenuationread-onlymandatoryThe value of this object provides the maximum value the RF Channel B Attenuation Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.21.2.1.23Columndrr2xalarmStateRFBAttenuationread-onlymandatoryThe value of this object provides the curent alarm state of the RF Channel B Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.24Columndrr2xlabelTrippointLevelread-onlyoptionalThe value of this object provides the label of the trip point level Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.25Columndrr2xuomTrippointLevelread-onlyoptionalThe value of this object provides the Unit of Measure of the trip point level Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.26Columndrr2xmajorHighTrippointLevelread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.21.2.1.27Columndrr2xmajorLowTrippointLevelread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.21.2.1.28Columndrr2xminorHighTrippointLevelread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.21.2.1.29Columndrr2xminorLowTrippointLevelread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.21.2.1.30Columndrr2xcurrentValueTrippointLevelread-writemandatoryThe value of this object provides the Current value of the trip point level Analog parameter. The trip point level set the custumer preferred optical input lev…
1.3.6.1.4.1.1166.6.1.2.21.2.1.31Columndrr2xstateFlagTrippointLevelread-onlymandatoryThe value of this object provides the state of the trip point level Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.21.2.1.32Columndrr2xminValueTrippointLevelread-onlymandatoryThe value of this object provides the minimum value the trip point level Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.21.2.1.33Columndrr2xmaxValueTrippointLevelread-onlymandatoryThe value of this object provides the maximum value the trip point level Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.21.2.1.34Columndrr2xalarmStateTrippointLevelread-onlymandatoryThe value of this object provides the curent alarm state of the trip point level Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.35Columndrr2xlabelOptCurrentread-onlyoptionalThe value of this object provides the label of the Optical Power Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.36Columndrr2xuomOptCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the Optical Power Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.37Columndrr2xmajorHighOptCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the Optical Power Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.38Columndrr2xmajorLowOptCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the Optical Power Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.39Columndrr2xminorHighOptCurrentread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.21.2.1.40Columndrr2xminorLowOptCurrentread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.21.2.1.41Columndrr2xcurrentValueOptCurrentread-onlymandatoryThe value of this object provides the Current value of the Optical Power Current Analog parameter. The input optical power in lower than min value, drr2xcurren…
1.3.6.1.4.1.1166.6.1.2.21.2.1.42Columndrr2xstateFlagOptCurrentread-onlymandatoryThe value of this object provides the state of the Optical Power Current Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.21.2.1.43Columndrr2xminValueOptCurrentread-onlymandatoryThis is recommended min range for display gauge
1.3.6.1.4.1.1166.6.1.2.21.2.1.44Columndrr2xmaxValueOptCurrentread-onlymandatoryThis is recommended max range for display gauge
1.3.6.1.4.1.1166.6.1.2.21.2.1.45Columndrr2xalarmStateOptCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the Optical Power Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.46Columndrr2xlabel12VCurrentread-onlyoptionalThe value of this object provides the label of the 12v power supply Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.47Columndrr2xuom12VCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the 12v power supply Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.48Columndrr2xmajorHigh12VCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the 12v power supply Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.49Columndrr2xmajorLow12VCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the 12v power supply Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.50Columndrr2xminorHigh12VCurrentread-onlymandatoryThe value of this object provides the Minor High alarm value of the 12v power supply Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.51Columndrr2xminorLow12VCurrentread-onlymandatoryThe value of this object provides the Minor Low alarm value of the 12v power supply Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.52Columndrr2xcurrentValue12VCurrentread-onlymandatoryThe value of this object provides the Current value of the 12v power supply Current parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.53Columndrr2xstateFlag12VCurrentread-onlymandatoryThe value of this object provides the state of the 12v power supply Current Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.21.2.1.54Columndrr2xminValue12VCurrentread-onlymandatoryThe value of this object provides the minimum value the 12v power supply Current Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.21.2.1.55Columndrr2xmaxValue12VCurrentread-onlymandatoryThe value of this object provides the maximum value the 12v power supply Current Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.21.2.1.56Columndrr2xalarmState12VCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the 12v power supply Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.57Columndrr2xlabelModTempread-onlyoptionalThe value of this object provides the label of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.58Columndrr2xuomModTempread-onlyoptionalThe value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.59Columndrr2xmajorHighModTempread-onlymandatoryThe value of this object provides the Major High alarm value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.60Columndrr2xmajorLowModTempread-onlymandatoryThe value of this object provides the Major Low alarm value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.61Columndrr2xminorHighModTempread-onlymandatoryThe value of this object provides the Minor High alarm value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.62Columndrr2xminorLowModTempread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.63Columndrr2xcurrentValueModTempread-onlymandatoryThe value of this object provides the Current value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.64Columndrr2xstateFlagModTempread-onlymandatoryThe value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.21.2.1.65Columndrr2xminValueModTempread-onlymandatoryThe value of this object provides the minimum value the Module Temperature Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.21.2.1.66Columndrr2xmaxValueModTempread-onlymandatoryThe value of this object provides the maximum value the Module Temperature Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.21.2.1.67Columndrr2xalarmStateModTempread-onlymandatoryThe value of this object provides the curent alarm state of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.68Columndrr2xlabelFanCurrentread-onlyoptionalThe value of this object provides the label of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.69Columndrr2xuomFanCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.70Columndrr2xmajorHighFanCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.71Columndrr2xmajorLowFanCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.72Columndrr2xminorHighFanCurrentread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.21.2.1.73Columndrr2xminorLowFanCurrentread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.21.2.1.74Columndrr2xcurrentValueFanCurrentread-onlymandatoryThe value of this object provides the Current value of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.2.1.75Columndrr2xstateFlagFanCurrentread-onlymandatoryThe value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.21.2.1.76Columndrr2xminValueFanCurrentread-onlymandatoryThe value of this object provides the minimum value the Fan Current Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.21.2.1.77Columndrr2xmaxValueFanCurrentread-onlymandatoryThe value of this object provides the maximum value the Fan Current Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.21.2.1.78Columndrr2xalarmStateFanCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.21.3Tablegx2drr2xDigitalTablenot-accessiblemandatoryThis table contains gx2drr2x specific digital parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.21.3Nodetrapdrr12VCurrentAlarmThis trap is issued when the 12V power supply Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this para…
1.3.6.1.4.1.1166.6.1.2.21.3.2Rowgx2drr2xDigitalEntrynot-accessiblemandatoryThis list contains individual digital parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.21.3.2.1Columngx2drr2xDigitalTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.21.3.2.2Columndrr2xlabelTrippointModeread-onlyoptionalThe value of this object provides the label of the Trip point mode Digital parameter. The trip point mode defines the RF switch action based on the optical pow…
1.3.6.1.4.1.1166.6.1.2.21.3.2.3Columndrr2xenumTrippointModeread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
1.3.6.1.4.1.1166.6.1.2.21.3.2.4Columndrr2xvalueTrippointModeread-writemandatoryThe value of this object is the current value of trip point mode. There are three possible value: 1-off, 2-alarm_only, 3-alarm&switch. If module input optical …
1.3.6.1.4.1.1166.6.1.2.21.3.2.5Columndrr2xstateflagTrippointModeread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.21.3.2.6Columndrr2xlabelFactoryDefaultResetread-onlyoptionalThe value of this object provides the label of the Factory Default Reset Digital parameter.
1.3.6.1.4.1.1166.6.1.2.21.3.2.7Columndrr2xenumFactoryDefaultResetread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.21.3.2.8Columndrr2xvalueFactoryDefaultResetread-writemandatoryThe read of this value will return a invalid value. The read will not reflect the actual setting value for this parameter
1.3.6.1.4.1.1166.6.1.2.21.3.2.9Columndrr2xstateflagFactoryDefaultResetread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.21.4Tablegx2drr2xStatusTablenot-accessiblemandatoryThis table contains gx2drr2x specific status parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.21.4NodetrapdrrModuleTempAlarmThis trap is issued when the Internal Module Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.21.4.3Rowgx2drr2xStatusEntrynot-accessiblemandatoryThis list contains Status parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.21.4.3.1Columngx2drr2xStatusTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.21.4.3.2Columndrr2xlabelBootread-onlyoptionalThe value of this object provides the label of the Boot Status parameter.
1.3.6.1.4.1.1166.6.1.2.21.4.3.3Columndrr2xvalueBootread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.21.4.3.4Columndrr2xstateflagBootread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.21.4.3.5Columndrr2xlabelFlashread-onlyoptionalThe value of this object provides the label of the Flash Status parameter.
1.3.6.1.4.1.1166.6.1.2.21.4.3.6Columndrr2xvalueFlashread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.21.4.3.7Columndrr2xstateflagFlashread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.21.4.3.8Columndrr2xlabelFactoryDataCRCread-onlyoptionalThe value of this object provides the label of the Factory Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.21.4.3.9Columndrr2xvalueFactoryDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.21.4.3.10Columndrr2xstateflagFactoryDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.21.4.3.11Columndrr2xlabelAlarmDataCrcread-onlyoptionalThe value of this object provides the label of the Alarm Data Crc parameter.
1.3.6.1.4.1.1166.6.1.2.21.4.3.12Columndrr2xvalueAlarmDataCrcread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.21.4.3.13Columndrr2xstateflagAlarmDataCrcread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.21.4.3.14Columndrr2xlabelCalibrationDataCrcread-onlyoptionalThe value of this object provides the label of the Calibration Data Crc parameter.
1.3.6.1.4.1.1166.6.1.2.21.4.3.15Columndrr2xvalueCalibrationDataCrcread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.21.4.3.16Columndrr2xstateflagCalibrationDataCrcread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.21.4.3.17Columndrr2xlabelHardwareStatusread-onlyoptionalThe value of this object provides the label of the Module Hardware Status parameter.
1.3.6.1.4.1.1166.6.1.2.21.4.3.18Columndrr2xvalueHardwareStatusread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.21.4.3.19Columndrr2xstateflagHardwareStatusread-onlymandatoryThe value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.21.4.3.20Columndrr2xlabelOpticTripPointStatusread-onlyoptionalThe value of this object provides the label of the Optical Trip Point Status parameter.It indicates whether the optical power is above(0) or below(1) trip poin…
1.3.6.1.4.1.1166.6.1.2.21.4.3.21Columndrr2xvalueOpticTripPointStatusread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.21.4.3.22Columndrr2xstateflagOpticTripPointStatusread-onlymandatoryThe value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.21.4.3.23Columndrr2xlabelLinkStatusread-onlyoptionalThe value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect t…
1.3.6.1.4.1.1166.6.1.2.21.4.3.24Columndrr2xvalueLinkStatusread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.21.4.3.25Columndrr2xstateflagLinkStatusread-onlymandatoryThe value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.21.5Tablegx2drr2xFactoryTablenot-accessiblemandatoryThis table contains gx2drr2x specific factory setting parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.21.5NodetrapdrrFanCurrentAlarmThis trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.21.5.4Rowgx2drr2xFactoryEntrynot-accessiblemandatoryThis list contains Factory setting parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.21.5.4.1Columngx2drr2xFactoryTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.21.5.4.2Columndrr2xbootControlByteread-onlymandatoryThe value of this object indicates which bank the firmware is currently being boot from.
1.3.6.1.4.1.1166.6.1.2.21.5.4.3Columndrr2xbootStatusByteread-onlymandatoryThis object indicates the status of the last boot
1.3.6.1.4.1.1166.6.1.2.21.5.4.4Columndrr2xbank1CRCread-onlymandatoryThis object provides the CRC code of bank 0.
1.3.6.1.4.1.1166.6.1.2.21.5.4.5Columndrr2xbank2CRCread-onlymandatoryThis object provides the CRC code of bank 1.
1.3.6.1.4.1.1166.6.1.2.21.5.4.6Columndrr2xprgEEPROMByteread-onlymandatoryThis object indicates if the EEPROM has been programmed
1.3.6.1.4.1.1166.6.1.2.21.5.4.7Columndrr2xfactoryCRCread-onlymandatoryThis object provides the CRC code for the Factory data.
1.3.6.1.4.1.1166.6.1.2.21.5.4.8Columndrr2xcalculateCRCread-onlymandatoryThis object indicates which of the Emnums will have the CRC calculated (1-factory, 2-alarm, 3-calibration).
1.3.6.1.4.1.1166.6.1.2.21.5.4.9Columndrr2xhourMeterread-onlymandatoryThis object provides the hour meter reading of the module.
1.3.6.1.4.1.1166.6.1.2.21.5.4.10Columndrr2xflashPrgCntAread-onlymandatoryThis object provides the number of times Bank 0 flash has been programmed.
1.3.6.1.4.1.1166.6.1.2.21.5.4.11Columndrr2xflashPrgCntBread-onlymandatoryThis object provides the number of times Bank 1 flash has been programmed.
1.3.6.1.4.1.1166.6.1.2.21.5.4.12Columndrr2xflashBankARevread-onlymandatoryThis object provides the revision of flash bank 0.
1.3.6.1.4.1.1166.6.1.2.21.5.4.13Columndrr2xflashBankBRevread-onlymandatoryThis object provides the revision of flash bank 1.
1.3.6.1.4.1.1166.6.1.2.21.5.4.14Columndrr2xSubAgentRevread-onlymandatoryThis object provides the subagent revision of receiver module.
1.3.6.1.4.1.1166.6.1.2.21.6NodetrapdrrFlashAlarmThis trap is issued when the detects an error during Flash memory operations.
1.3.6.1.4.1.1166.6.1.2.21.7NodetrapdrrBankBootAlarmThis trap is issued when the module detects an error while booting from bank 0 or bank 1.
1.3.6.1.4.1.1166.6.1.2.21.8NodetrapdrrAlarmDataCRCAlarmThis trap is issued when the Alarm Data CRC is incorrect.
1.3.6.1.4.1.1166.6.1.2.21.9NodetrapdrrHardwareErrAlarmThis trap is issued when hardware is abnormal.
1.3.6.1.4.1.1166.6.1.2.21.10NodetrapdrrOpticalSignalAlarmThis trap is issued when the optical signal is beyond the preset range.
1.3.6.1.4.1.1166.6.1.2.21.11NodetrapdrrFactoryDataCRCAlarmThis trap is issued when the Factory Data CRC is incorrect.
1.3.6.1.4.1.1166.6.1.2.21.12NodetrapdrrResetFactoryDefaultAlarmThis trap is issued when the Factory Default Reset occurs.
1.3.6.1.4.1.1166.6.1.2.21.13NodetrapdrrTripPointAlarmThis trap is issued when the Input optical power is lower than the custumer set trip point and trippoint mode as ALARM_ONLY or SWITCH & ALARM.
1.3.6.1.4.1.1166.6.1.2.21.14NodetrapdrrLinkAlarmThis trap is issued when receiver is out of SYN with transmitter
1.3.6.1.4.1.1166.6.1.2.21.15NodetrapdrrCalibrationDataCRCAlarmThis trap is issued when the Calibration Data CRC is incorrect