MIB Viewer

OMNI-gx2drr4x-MIB

172 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.1166.6.1.2.14.1Nodegx2drr4xDescriptor
1.3.6.1.4.1.1166.6.1.2.14.1NodetrapdrrConfigChangeIntegerThis trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre…
1.3.6.1.4.1.1166.6.1.2.14.2Tablegx2drr4xAnalogTablenot-accessiblemandatoryThis table contains gx2drr4x specific analog parameters with nominal,limits and current values.
1.3.6.1.4.1.1166.6.1.2.14.2NodetrapdrrConfigChangeDisplayStringThis trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may …
1.3.6.1.4.1.1166.6.1.2.14.2.1Rowgx2drr4xAnalogEntrynot-accessiblemandatoryThis list contains the analog parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.14.2.1.1Columngx2drr4xAnalogTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.14.2.1.2Columndrr4xlabelRFAAttenuationread-onlyoptionalThe value of this object provides the label of the RF Channel A Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.3Columndrr4xuomRFAAttenuationread-onlyoptionalThe value of this object provides the Unit of Measure of the RF Channel A Attenuation Analog parameter. The unit is in dB
1.3.6.1.4.1.1166.6.1.2.14.2.1.4Columndrr4xmajorHighRFAAttenuationread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.14.2.1.5Columndrr4xmajorLowRFAAttenuationread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.14.2.1.6Columndrr4xminorHighRFAAttenuationread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.14.2.1.7Columndrr4xminorLowRFAAttenuationread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.14.2.1.8Columndrr4xcurrentValueRFAAttenuationread-writemandatoryThe value of this object provides the Current value of the RF Channel A Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.9Columndrr4xstateFlagRFAAttenuationread-onlymandatoryThe value of this object provides the state of the RF Channel A Attenuation Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.14.2.1.10Columndrr4xminValueRFAAttenuationread-onlymandatoryThe value of this object provides the minimum value the RF Channel A Attenuation Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.14.2.1.11Columndrr4xmaxValueRFAAttenuationread-onlymandatoryThe value of this object provides the maximum value the RF Channel A Attenuation Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.14.2.1.12Columndrr4xalarmStateRFAAttenuationread-onlymandatoryThe value of this object provides the curent alarm state of the RF Channel A Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.13Columndrr4xlabelRFBAttenuationread-onlyoptionalThe value of this object provides the label of the RF Channel B Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.14Columndrr4xuomRFBAttenuationread-onlyoptionalThe value of this object provides the Unit of Measure of the RF Channel B Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.15Columndrr4xmajorHighRFBAttenuationread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.14.2.1.16Columndrr4xmajorLowRFBAttenuationread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.14.2.1.17Columndrr4xminorHighRFBAttenuationread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.14.2.1.18Columndrr4xminorLowRFBAttenuationread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF. It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.14.2.1.19Columndrr4xcurrentValueRFBAttenuationread-writemandatoryThe value of this object provides the Current value of the RF Channel B Attenuation Analog parameter. The unit is dB
1.3.6.1.4.1.1166.6.1.2.14.2.1.20Columndrr4xstateFlagRFBAttenuationread-onlymandatoryThe value of this object provides the state of the RF Channel B Attenuation Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.14.2.1.21Columndrr4xminValueRFBAttenuationread-onlymandatoryThe value of this object provides the minimum value the RF Channel B Attenuation Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.14.2.1.22Columndrr4xmaxValueRFBAttenuationread-onlymandatoryThe value of this object provides the maximum value the RF Channel B Attenuation Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.14.2.1.23Columndrr4xalarmStateRFBAttenuationread-onlymandatoryThe value of this object provides the curent alarm state of the RF Channel B Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.24Columndrr4xlabelRFCAttenuationread-onlyoptionalThe value of this object provides the label of the RF Channel C Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.25Columndrr4xuomRFCAttenuationread-onlyoptionalThe value of this object provides the Unit of Measure of the RF Channel C Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.26Columndrr4xmajorHighRFCAttenuationread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.14.2.1.27Columndrr4xmajorLowRFCAttenuationread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.14.2.1.28Columndrr4xminorHighRFCAttenuationread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.14.2.1.29Columndrr4xminorLowRFCAttenuationread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF. It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.14.2.1.30Columndrr4xcurrentValueRFCAttenuationread-writemandatoryThe value of this object provides the Current value of the RF Channel C Attenuation Analog parameter. The unit is dB
1.3.6.1.4.1.1166.6.1.2.14.2.1.31Columndrr4xstateFlagRFCAttenuationread-onlymandatoryThe value of this object provides the state of the RF Channel C Attenuation Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.14.2.1.32Columndrr4xminValueRFCAttenuationread-onlymandatoryThe value of this object provides the minimum value the RF Channel C Attenuation Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.14.2.1.33Columndrr4xmaxValueRFCAttenuationread-onlymandatoryThe value of this object provides the maximum value the RF Channel C Attenuation Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.14.2.1.34Columndrr4xalarmStateRFCAttenuationread-onlymandatoryThe value of this object provides the curent alarm state of the RF Channel C Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.35Columndrr4xlabelRFDAttenuationread-onlyoptionalThe value of this object provides the label of the RF Channel D Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.36Columndrr4xuomRFDAttenuationread-onlyoptionalThe value of this object provides the Unit of Measure of the RF Channel D Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.37Columndrr4xmajorHighRFDAttenuationread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.14.2.1.38Columndrr4xmajorLowRFDAttenuationread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.14.2.1.39Columndrr4xminorHighRFDAttenuationread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.14.2.1.40Columndrr4xminorLowRFDAttenuationread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF. It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.14.2.1.41Columndrr4xcurrentValueRFDAttenuationread-writemandatoryThe value of this object provides the Current value of the RF Channel D Attenuation Analog parameter. The unit is dB
1.3.6.1.4.1.1166.6.1.2.14.2.1.42Columndrr4xstateFlagRFDAttenuationread-onlymandatoryThe value of this object provides the state of the RF Channel D Attenuation Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.14.2.1.43Columndrr4xminValueRFDAttenuationread-onlymandatoryThe value of this object provides the minimum value the RF Channel B Attenuation Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.14.2.1.44Columndrr4xmaxValueRFDAttenuationread-onlymandatoryThe value of this object provides the maximum value the RF Channel D Attenuation Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.14.2.1.45Columndrr4xalarmStateRFDAttenuationread-onlymandatoryThe value of this object provides the curent alarm state of the RF Channel D Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.46Columndrr4xlabelTrippointLevelread-onlyoptionalThe value of this object provides the label of the trip point level Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.47Columndrr4xuomTrippointLevelread-onlyoptionalThe value of this object provides the Unit of Measure of the trip point level Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.48Columndrr4xmajorHighTrippointLevelread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.14.2.1.49Columndrr4xmajorLowTrippointLevelread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.14.2.1.50Columndrr4xminorHighTrippointLevelread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.14.2.1.51Columndrr4xminorLowTrippointLevelread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.14.2.1.52Columndrr4xcurrentValueTrippointLevelread-writemandatoryThe value of this object provides the Current value of the trip point level Analog parameter. The trip point level set the custumer preferred optical input lev…
1.3.6.1.4.1.1166.6.1.2.14.2.1.53Columndrr4xstateFlagTrippointLevelread-onlymandatoryThe value of this object provides the state of the trip point level Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.14.2.1.54Columndrr4xminValueTrippointLevelread-onlymandatoryThe value of this object provides the minimum value the trip point level Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.14.2.1.55Columndrr4xmaxValueTrippointLevelread-onlymandatoryThe value of this object provides the maximum value the trip point level Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.14.2.1.56Columndrr4xalarmStateTrippointLevelread-onlymandatoryThe value of this object provides the curent alarm state of the trip point level Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.57Columndrr4xlabelOptCurrentread-onlyoptionalThe value of this object provides the label of the Optical Power Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.58Columndrr4xuomOptCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the Optical Power Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.59Columndrr4xmajorHighOptCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the Optical Power Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.60Columndrr4xmajorLowOptCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the Optical Power Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.61Columndrr4xminorHighOptCurrentread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.14.2.1.62Columndrr4xminorLowOptCurrentread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.14.2.1.63Columndrr4xcurrentValueOptCurrentread-onlymandatoryThe value of this object provides the Current value of the Optical Power Current Analog parameter. The input optical power in lower than min value, drr4xcurren…
1.3.6.1.4.1.1166.6.1.2.14.2.1.64Columndrr4xstateFlagOptCurrentread-onlymandatoryThe value of this object provides the state of the Optical Power Current Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.14.2.1.65Columndrr4xminValueOptCurrentread-onlymandatoryThis is recommended min range for display gauge
1.3.6.1.4.1.1166.6.1.2.14.2.1.66Columndrr4xmaxValueOptCurrentread-onlymandatoryThis is recommended max range for display gauge
1.3.6.1.4.1.1166.6.1.2.14.2.1.67Columndrr4xalarmStateOptCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the Optical Power Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.68Columndrr4xlabel12VCurrentread-onlyoptionalThe value of this object provides the label of the 12v power supply Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.69Columndrr4xuom12VCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the 12v power supply Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.70Columndrr4xmajorHigh12VCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the 12v power supply Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.71Columndrr4xmajorLow12VCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the 12v power supply Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.72Columndrr4xminorHigh12VCurrentread-onlymandatoryThe value of this object provides the Minor High alarm value of the 12v power supply Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.73Columndrr4xminorLow12VCurrentread-onlymandatoryThe value of this object provides the Minor Low alarm value of the 12v power supply Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.74Columndrr4xcurrentValue12VCurrentread-onlymandatoryThe value of this object provides the Current value of the 12v power supply Current parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.75Columndrr4xstateFlag12VCurrentread-onlymandatoryThe value of this object provides the state of the 12v power supply Current Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.14.2.1.76Columndrr4xminValue12VCurrentread-onlymandatoryThe value of this object provides the minimum value the 12v power supply Current Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.14.2.1.77Columndrr4xmaxValue12VCurrentread-onlymandatoryThe value of this object provides the maximum value the 12v power supply Current Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.14.2.1.78Columndrr4xalarmState12VCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the 12v power supply Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.79Columndrr4xlabelModTempread-onlyoptionalThe value of this object provides the label of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.80Columndrr4xuomModTempread-onlyoptionalThe value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.81Columndrr4xmajorHighModTempread-onlymandatoryThe value of this object provides the Major High alarm value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.82Columndrr4xmajorLowModTempread-onlymandatoryThe value of this object provides the Major Low alarm value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.83Columndrr4xminorHighModTempread-onlymandatoryThe value of this object provides the Minor High alarm value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.84Columndrr4xminorLowModTempread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.85Columndrr4xcurrentValueModTempread-onlymandatoryThe value of this object provides the Current value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.86Columndrr4xstateFlagModTempread-onlymandatoryThe value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.14.2.1.87Columndrr4xminValueModTempread-onlymandatoryThe value of this object provides the minimum value the Module Temperature Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.14.2.1.88Columndrr4xmaxValueModTempread-onlymandatoryThe value of this object provides the maximum value the Module Temperature Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.14.2.1.89Columndrr4xalarmStateModTempread-onlymandatoryThe value of this object provides the curent alarm state of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.90Columndrr4xlabelFanCurrentread-onlyoptionalThe value of this object provides the label of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.91Columndrr4xuomFanCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.92Columndrr4xmajorHighFanCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.93Columndrr4xmajorLowFanCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.94Columndrr4xminorHighFanCurrentread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.14.2.1.95Columndrr4xminorLowFanCurrentread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.14.2.1.96Columndrr4xcurrentValueFanCurrentread-onlymandatoryThe value of this object provides the Current value of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.2.1.97Columndrr4xstateFlagFanCurrentread-onlymandatoryThe value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.14.2.1.98Columndrr4xminValueFanCurrentread-onlymandatoryThe value of this object provides the minimum value the Fan Current Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.14.2.1.99Columndrr4xmaxValueFanCurrentread-onlymandatoryThe value of this object provides the maximum value the Fan Current Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.14.2.1.100Columndrr4xalarmStateFanCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.14.3Tablegx2drr4xDigitalTablenot-accessiblemandatoryThis table contains gx2drr4x specific digital parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.14.3Nodetrapdrr12VCurrentAlarmThis trap is issued when the 12V power supply Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this para…
1.3.6.1.4.1.1166.6.1.2.14.3.2Rowgx2drr4xDigitalEntrynot-accessiblemandatoryThis list contains individual digital parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.14.3.2.1Columngx2drr4xDigitalTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.14.3.2.2Columndrr4xlabelTrippointModeread-onlyoptionalThe value of this object provides the label of the Trip point mode Digital parameter. The trip point mode defines the RF switch action based on the optical pow…
1.3.6.1.4.1.1166.6.1.2.14.3.2.3Columndrr4xenumTrippointModeread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
1.3.6.1.4.1.1166.6.1.2.14.3.2.4Columndrr4xvalueTrippointModeread-writemandatoryThe value of this object is the current value of trip point mode. There are three possible value: 1-off, 2-alarm_only, 3-alarm&switch. If module input optical …
1.3.6.1.4.1.1166.6.1.2.14.3.2.5Columndrr4xstateflagTrippointModeread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.14.3.2.6Columndrr4xlabelFactoryDefaultResetread-onlyoptionalThe value of this object provides the label of the Factory Default Reset Digital parameter.
1.3.6.1.4.1.1166.6.1.2.14.3.2.7Columndrr4xenumFactoryDefaultResetread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.14.3.2.8Columndrr4xvalueFactoryDefaultResetread-writemandatoryThe read of this value will return a invalid value. The read will not reflect the actual setting value for this parameter
1.3.6.1.4.1.1166.6.1.2.14.3.2.9Columndrr4xstateflagFactoryDefaultResetread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.14.4Tablegx2drr4xStatusTablenot-accessiblemandatoryThis table contains gx2drr4x specific status parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.14.4NodetrapdrrModuleTempAlarmThis trap is issued when the Internal Module Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.14.4.3Rowgx2drr4xStatusEntrynot-accessiblemandatoryThis list contains Status parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.14.4.3.1Columngx2drr4xStatusTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.14.4.3.2Columndrr4xlabelBootread-onlyoptionalThe value of this object provides the label of the Boot Status parameter.
1.3.6.1.4.1.1166.6.1.2.14.4.3.3Columndrr4xvalueBootread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.14.4.3.4Columndrr4xstateflagBootread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.14.4.3.5Columndrr4xlabelFlashread-onlyoptionalThe value of this object provides the label of the Flash Status parameter.
1.3.6.1.4.1.1166.6.1.2.14.4.3.6Columndrr4xvalueFlashread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.14.4.3.7Columndrr4xstateflagFlashread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.14.4.3.8Columndrr4xlabelFactoryDataCRCread-onlyoptionalThe value of this object provides the label of the Factory Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.14.4.3.9Columndrr4xvalueFactoryDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.14.4.3.10Columndrr4xstateflagFactoryDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.14.4.3.11Columndrr4xlabelAlarmDataCrcread-onlyoptionalThe value of this object provides the label of the Alarm Data Crc parameter.
1.3.6.1.4.1.1166.6.1.2.14.4.3.12Columndrr4xvalueAlarmDataCrcread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.14.4.3.13Columndrr4xstateflagAlarmDataCrcread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.14.4.3.14Columndrr4xlabelCalibrationDataCrcread-onlyoptionalThe value of this object provides the label of the Calibration Data Crc parameter.
1.3.6.1.4.1.1166.6.1.2.14.4.3.15Columndrr4xvalueCalibrationDataCrcread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.14.4.3.16Columndrr4xstateflagCalibrationDataCrcread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.14.4.3.17Columndrr4xlabelHardwareStatusread-onlyoptionalThe value of this object provides the label of the Module Hardware Status parameter.
1.3.6.1.4.1.1166.6.1.2.14.4.3.18Columndrr4xvalueHardwareStatusread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.14.4.3.19Columndrr4xstateflagHardwareStatusread-onlymandatoryThe value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.14.4.3.20Columndrr4xlabelOpticTripPointStatusread-onlyoptionalThe value of this object provides the label of the Optical Trip Point Status parameter.It indicates whether the optical power is above(0) or below(1) trip poin…
1.3.6.1.4.1.1166.6.1.2.14.4.3.21Columndrr4xvalueOpticTripPointStatusread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.14.4.3.22Columndrr4xstateflagOpticTripPointStatusread-onlymandatoryThe value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.14.4.3.23Columndrr4xlabelLinkStatusread-onlyoptionalThe value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect t…
1.3.6.1.4.1.1166.6.1.2.14.4.3.24Columndrr4xvalueLinkStatusread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.14.4.3.25Columndrr4xstateflagLinkStatusread-onlymandatoryThe value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.14.5Tablegx2drr4xFactoryTablenot-accessiblemandatoryThis table contains gx2drr4x specific factory setting parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.14.5NodetrapdrrFanCurrentAlarmThis trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.14.5.4Rowgx2drr4xFactoryEntrynot-accessiblemandatoryThis list contains Factory setting parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.14.5.4.1Columngx2drr4xFactoryTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.14.5.4.2Columndrr4xbootControlByteread-onlymandatoryThe value of this object indicates which bank the firmware is currently being boot from.
1.3.6.1.4.1.1166.6.1.2.14.5.4.3Columndrr4xbootStatusByteread-onlymandatoryThis object indicates the status of the last boot
1.3.6.1.4.1.1166.6.1.2.14.5.4.4Columndrr4xbank1CRCread-onlymandatoryThis object provides the CRC code of bank 0.
1.3.6.1.4.1.1166.6.1.2.14.5.4.5Columndrr4xbank2CRCread-onlymandatoryThis object provides the CRC code of bank 1.
1.3.6.1.4.1.1166.6.1.2.14.5.4.6Columndrr4xprgEEPROMByteread-onlymandatoryThis object indicates if the EEPROM has been programmed
1.3.6.1.4.1.1166.6.1.2.14.5.4.7Columndrr4xfactoryCRCread-onlymandatoryThis object provides the CRC code for the Factory data.
1.3.6.1.4.1.1166.6.1.2.14.5.4.8Columndrr4xcalculateCRCread-onlymandatoryThis object indicates which of the Emnums will have the CRC calculated (1-factory, 2-alarm, 3-calibration).
1.3.6.1.4.1.1166.6.1.2.14.5.4.9Columndrr4xhourMeterread-onlymandatoryThis object provides the hour meter reading of the module.
1.3.6.1.4.1.1166.6.1.2.14.5.4.10Columndrr4xflashPrgCntAread-onlymandatoryThis object provides the number of times Bank 0 flash has been programmed.
1.3.6.1.4.1.1166.6.1.2.14.5.4.11Columndrr4xflashPrgCntBread-onlymandatoryThis object provides the number of times Bank 1 flash has been programmed.
1.3.6.1.4.1.1166.6.1.2.14.5.4.12Columndrr4xflashBankARevread-onlymandatoryThis object provides the revision of flash bank 0.
1.3.6.1.4.1.1166.6.1.2.14.5.4.13Columndrr4xflashBankBRevread-onlymandatoryThis object provides the revision of flash bank 1.
1.3.6.1.4.1.1166.6.1.2.14.5.4.14Columndrr4xSubAgentRevread-onlymandatoryThis object provides the subagent revision of receiver module.
1.3.6.1.4.1.1166.6.1.2.14.6NodetrapdrrFlashAlarmThis trap is issued when the detects an error during Flash memory operations.
1.3.6.1.4.1.1166.6.1.2.14.7NodetrapdrrBankBootAlarmThis trap is issued when the module detects an error while booting from bank 0 or bank 1.
1.3.6.1.4.1.1166.6.1.2.14.8NodetrapdrrAlarmDataCRCAlarmThis trap is issued when the Alarm Data CRC is incorrect.
1.3.6.1.4.1.1166.6.1.2.14.9NodetrapdrrHardwareErrAlarmThis trap is issued when hardware is abnormal.
1.3.6.1.4.1.1166.6.1.2.14.10NodetrapdrrOpticalSignalAlarmThis trap is issued when the optical signal is beyond the preset range.
1.3.6.1.4.1.1166.6.1.2.14.11NodetrapdrrFactoryDataCRCAlarmThis trap is issued when the Factory Data CRC is incorrect.
1.3.6.1.4.1.1166.6.1.2.14.12NodetrapdrrResetFactoryDefaultAlarmThis trap is issued when the Factory Default Reset occurs.
1.3.6.1.4.1.1166.6.1.2.14.13NodetrapdrrTripPointAlarmThis trap is issued when the Input optical power is lower than the custumer set trip point and trippoint mode as ALARM_ONLY or SWITCH & ALARM.
1.3.6.1.4.1.1166.6.1.2.14.14NodetrapdrrLinkAlarmThis trap is issued when receiver is out of SYN with transmitter
1.3.6.1.4.1.1166.6.1.2.14.15NodetrapdrrCalibrationDataCRCAlarmThis trap is issued when the Calibration Data CRC is incorrect