MIB Viewer

OMNI-gx2dualdrr2x-MIB

317 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.1166.6.1.2.35.1Nodegx2dualdrr2xDescriptor
1.3.6.1.4.1.1166.6.1.2.35.1NodetrapdualdrrConfigChangeIntegerThis trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre…
1.3.6.1.4.1.1166.6.1.2.35.2Tablegx2dualdrr2xAnalogTablenot-accessiblemandatoryThis table contains gx2dualdrr2x specific analog parameters with nominal,limits and current values.
1.3.6.1.4.1.1166.6.1.2.35.2NodetrapdualdrrConfigChangeDisplayStringThis trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may …
1.3.6.1.4.1.1166.6.1.2.35.2.1Rowgx2dualdrr2xAnalogEntrynot-accessiblemandatoryThis list contains the analog parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.35.2.1.1Columngx2dualdrr2xAnalogTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.35.2.1.2Columndualdrr2xlabelRecdOptPwr1read-onlyoptionalThe value of this object provides the label of the Channel 1 Received Opt power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.3Columndualdrr2xuomRecdOptPwr1read-onlyoptionalThe value of this object provides the Unit of Measure of the Channel 1 Received Opt power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.4Columndualdrr2xmajorHighRecdOptPwr1read-onlyobsoleteThis object is not used by this module and always returns the value of the Channel 1 Received Opt power Major High Alarm Limit Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.5Columndualdrr2xmajorLowRecdOptPwr1read-onlyobsoleteThis object is not used by this module and always returns the value of the Channel 1 Received Opt power Major High Alarm Limit Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.6Columndualdrr2xminorHighRecdOptPwr1read-onlyobsoleteThis object is not used by this module and always returns the value of 10^e10 . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.35.2.1.7Columndualdrr2xminorLowRecdOptPwr1read-onlyobsoleteThis object is not used by this module and always returns the value of 10^e10 . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.35.2.1.8Columndualdrr2xcurrentValueRecdOptPwr1read-writemandatoryThe value of this object provides the Current value of the Channel 1 Received Opt power.
1.3.6.1.4.1.1166.6.1.2.35.2.1.9Columndualdrr2xstateFlagRecdOptPwr1read-onlymandatoryThe value of this object provides the state of the Channel 1 Received Opt power Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.35.2.1.10Columndualdrr2xminValueRecdOptPwr1read-onlymandatoryThe value of this object provides the minimum value of the Channel 1 Received Opt power.
1.3.6.1.4.1.1166.6.1.2.35.2.1.11Columndualdrr2xmaxValueRecdOptPwr1read-onlymandatoryThe value of this object provides the maximum value of the Channel 1 Received Opt power.
1.3.6.1.4.1.1166.6.1.2.35.2.1.12Columndualdrr2xalarmStateRecdOptPwr1read-onlymandatoryThe value of this object provides the curent alarm state of the Channel 1 Received Opt power.
1.3.6.1.4.1.1166.6.1.2.35.2.1.13Columndualdrr2xlabelRecdOptPwr2read-onlyoptionalThe value of this object provides the label of the Channel 2 Received Opt power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.14Columndualdrr2xuomRecdOptPwr2read-onlyoptionalThe value of this object provides the Unit of Measure of the Channel 2 Received Opt power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.15Columndualdrr2xmajorHighRecdOptPwr2read-onlyobsoleteThis object is not used by this module and always returns the value of the Channel 2 Received Opt power Major High Alarm Limit Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.16Columndualdrr2xmajorLowRecdOptPwr2read-onlyobsoleteThis object is not used by this module and always returns the value of the Channel 2 Received Opt power Major High Alarm Limit Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.17Columndualdrr2xminorHighRecdOptPwr2read-onlyobsoleteThis object is not used by this module and always returns the value of 10^e10 . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.35.2.1.18Columndualdrr2xminorLowRecdOptPwr2read-onlyobsoleteThis object is not used by this module and always returns the value of 10^e10 . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.35.2.1.19Columndualdrr2xcurrentValueRecdOptPwr2read-writemandatoryThe value of this object provides the Current value of the Channel 2 Received Opt power.
1.3.6.1.4.1.1166.6.1.2.35.2.1.20Columndualdrr2xstateFlagRecdOptPwr2read-onlymandatoryThe value of this object provides the state of the Channel 2 Received Opt power Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.35.2.1.21Columndualdrr2xminValueRecdOptPwr2read-onlymandatoryThe value of this object provides the minimum value of the Channel 2 Received Opt power.
1.3.6.1.4.1.1166.6.1.2.35.2.1.22Columndualdrr2xmaxValueRecdOptPwr2read-onlymandatoryThe value of this object provides the maximum value of the Channel 2 Received Opt power.
1.3.6.1.4.1.1166.6.1.2.35.2.1.23Columndualdrr2xalarmStateRecdOptPwr2read-onlymandatoryThe value of this object provides the curent alarm state of the Channel 2 Received optical power.
1.3.6.1.4.1.1166.6.1.2.35.2.1.24Columndualdrr2xlabelModTempread-onlyoptionalThe value of this object provides the label of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.25Columndualdrr2xuomModTempread-onlyoptionalThe value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.26Columndualdrr2xmajorHighModTempread-onlymandatoryThe value of this object provides the Major High alarm value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.27Columndualdrr2xmajorLowModTempread-onlymandatoryThe value of this object provides the Major Low alarm value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.28Columndualdrr2xminorHighModTempread-onlymandatoryThe value of this object provides the Minor High alarm value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.29Columndualdrr2xminorLowModTempread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.30Columndualdrr2xcurrentValueModTempread-onlymandatoryThe value of this object provides the Current value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.31Columndualdrr2xstateFlagModTempread-onlymandatoryThe value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.35.2.1.32Columndualdrr2xminValueModTempread-onlymandatoryThe value of this object provides the minimum value the Module Temperature Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.35.2.1.33Columndualdrr2xmaxValueModTempread-onlymandatoryThe value of this object provides the maximum value the Module Temperature Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.35.2.1.34Columndualdrr2xalarmStateModTempread-onlymandatoryThe value of this object provides the curent alarm state of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.35Columndualdrr2xlabel12VCurrentread-onlyoptionalThe value of this object provides the label of the 12v power supply Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.36Columndualdrr2xuom12VCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the 12v power supply Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.37Columndualdrr2xmajorHigh12VCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the 12v power supply Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.38Columndualdrr2xmajorLow12VCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the 12v power supply Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.39Columndualdrr2xminorHigh12VCurrentread-onlymandatoryThe value of this object provides the Minor High alarm value of the 12v power supply Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.40Columndualdrr2xminorLow12VCurrentread-onlymandatoryThe value of this object provides the Minor Low alarm value of the 12v power supply Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.41Columndualdrr2xcurrentValue12VCurrentread-onlymandatoryThe value of this object provides the Current value of the 12v power supply Current parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.42Columndualdrr2xstateFlag12VCurrentread-onlymandatoryThe value of this object provides the state of the 12v power supply Current Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.35.2.1.43Columndualdrr2xminValue12VCurrentread-onlymandatoryThe value of this object provides the minimum value the 12v power supply Current Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.35.2.1.44Columndualdrr2xmaxValue12VCurrentread-onlymandatoryThe value of this object provides the maximum value the 12v power supply Current Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.35.2.1.45Columndualdrr2xalarmState12VCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the 12v power supply Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.46Columndualdrr2xlabelFanSpeedread-onlyoptionalThe value of this object provides the label of the Fan Speed Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.47Columndualdrr2xuomFanSpeedread-onlyoptionalThe value of this object provides the Unit of Measure of the Fan Speed Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.48Columndualdrr2xmajorHighFanSpeedread-onlymandatoryThe value of this object provides the Major High alarm value of the Fan Speed Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.49Columndualdrr2xmajorLowFanSpeedread-onlymandatoryThe value of this object provides the Major Low alarm value of the Fan Speed Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.50Columndualdrr2xminorHighFanSpeedread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.35.2.1.51Columndualdrr2xminorLowFanSpeedread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.35.2.1.52Columndualdrr2xcurrentValueFanSpeedread-onlymandatoryThe value of this object provides the current value of the Fan Speed Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.53Columndualdrr2xstateFlagFanSpeedread-onlymandatoryThe value of this object provides the state of the Fan Speed Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.35.2.1.54Columndualdrr2xminValueFanSpeedread-onlymandatoryThe value of this object provides the minimum value the Fan Speed Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.35.2.1.55Columndualdrr2xmaxValueFanSpeedread-onlymandatoryThe value of this object provides the maximum value the Fan Speed Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.35.2.1.56Columndualdrr2xalarmStateFanSpeedread-onlymandatoryThe value of this object provides the curent alarm state of the Fan Speed Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.57Columndualdrr2xlabelTx0SFPWaveread-onlyoptionalThe value of this object provides the label of the Tx 0 SFP Wavelength Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.58Columndualdrr2xuomTx0SFPWaveread-onlyoptionalThe value of this object provides the Unit of Measure of the Tx 0 SFP Wavelength Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.59Columndualdrr2xmajorHighTx0SFPWaveread-onlymandatoryThe value of this object provides the Major High alarm value of the Tx 0 SFP Wavelength Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.60Columndualdrr2xmajorLowTx0SFPWaveread-onlymandatoryThe value of this object provides the Major Low alarm value of the Tx 0 SFP Wavelength Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.61Columndualdrr2xminorHighTx0SFPWaveread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.35.2.1.62Columndualdrr2xminorLowTx0SFPWaveread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.35.2.1.63Columndualdrr2xcurrentValueTx0SFPWaveread-onlymandatoryThe value of this object provides the current value of the Tx 0 SFP Wavelength Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.64Columndualdrr2xstateFlagTx0SFPWaveread-onlymandatoryThe value of this object provides the state of the Tx 0 SFP Wavelength Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.35.2.1.65Columndualdrr2xminValueTx0SFPWaveread-onlymandatoryThe value of this object provides the minimum value the Tx 0 SFP Wavelength Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.35.2.1.66Columndualdrr2xmaxValueTx0SFPWaveread-onlymandatoryThe value of this object provides the maximum value the Tx 0 SFP Wavelength Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.35.2.1.67Columndualdrr2xalarmStateTx0SFPWaveread-onlymandatoryThe value of this object provides the curent alarm state of the Tx 0 SFP Wavelength Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.68Columndualdrr2xlabelTx0OptPwrread-onlyoptionalThe value of this object provides the label of the Tx 0 Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.69Columndualdrr2xuomTx0OptPwrread-onlyoptionalThe value of this object provides the Unit of Measure of the Tx 0 Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.70Columndualdrr2xmajorHighTx0OptPwrread-onlymandatoryThe value of this object provides the Major High alarm value of the Tx 0 Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.71Columndualdrr2xmajorLowTx0OptPwrread-onlymandatoryThe value of this object provides the Major Low alarm value of the Tx 0 Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.72Columndualdrr2xminorHighTx0OptPwrread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.35.2.1.73Columndualdrr2xminorLowTx0OptPwrread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.35.2.1.74Columndualdrr2xcurrentValueTx0OptPwrread-onlymandatoryThe value of this object provides the current value of the Tx 0 Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.75Columndualdrr2xstateFlagTx0OptPwrread-onlymandatoryThe value of this object provides the state of the Tx 0 Optical Power Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.35.2.1.76Columndualdrr2xminValueTx0OptPwrread-onlymandatoryThe value of this object provides the minimum value the Tx 0 Optical Power Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.35.2.1.77Columndualdrr2xmaxValueTx0OptPwrread-onlymandatoryThe value of this object provides the maximum value the Tx 0 Optical Power Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.35.2.1.78Columndualdrr2xalarmStateTx0OptPwrread-onlymandatoryThe value of this object provides the curent alarm state of the Tx 0 Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.79Columndualdrr2xlabelTx024vCurrread-onlyoptionalThe value of this object provides the label of the Tx 0 24 Volt Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.80Columndualdrr2xuomTx024vCurrread-onlyoptionalThe value of this object provides the Unit of Measure of the Tx 0 24 Volt Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.81Columndualdrr2xmajorHighTx024vCurrread-onlymandatoryThe value of this object provides the Major High alarm value of the Tx 0 24 Volt Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.82Columndualdrr2xmajorLowTx024vCurrread-onlymandatoryThe value of this object provides the Major Low alarm value of the Tx 0 24 Volt Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.83Columndualdrr2xminorHighTx024vCurrread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.35.2.1.84Columndualdrr2xminorLowTx024vCurrread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.35.2.1.85Columndualdrr2xcurrentValueTx024vCurrread-onlymandatoryThe value of this object provides the current value of the Tx 0 24 Volt Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.86Columndualdrr2xstateFlagTx024vCurrread-onlymandatoryThe value of this object provides the state of the Tx 0 24 Volt Current Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.35.2.1.87Columndualdrr2xminValueTx024vCurrread-onlymandatoryThe value of this object provides the minimum value the Tx 0 24 Volt Current Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.35.2.1.88Columndualdrr2xmaxValueTx024vCurrread-onlymandatoryThe value of this object provides the maximum value the Tx 0 24 Volt Current Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.35.2.1.89Columndualdrr2xalarmStateTx024vCurrread-onlymandatoryThe value of this object provides the curent alarm state of the Tx 0 24 Volt Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.90Columndualdrr2xlabelTx024Voltread-onlyoptionalThe value of this object provides the label of the Tx 0 24 Volt supply voltage Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.91Columndualdrr2xuomTx024Voltread-onlyoptionalThe value of this object provides the Unit of Measure of the Tx 0 24 Volt supply voltage Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.92Columndualdrr2xmajorHighTx024Voltread-onlymandatoryThe value of this object provides the Major High alarm value of the Tx 0 24 Volt supply voltage Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.93Columndualdrr2xmajorLowTx024Voltread-onlymandatoryThe value of this object provides the Major Low alarm value of the Tx 0 24 Volt supply voltage Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.94Columndualdrr2xminorHighTx024Voltread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.35.2.1.95Columndualdrr2xminorLowTx024Voltread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.35.2.1.96Columndualdrr2xcurrentValueTx024Voltread-onlymandatoryThe value of this object provides the current value of the Tx 0 24 Volt supply voltage Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.97Columndualdrr2xstateFlagTx024Voltread-onlymandatoryThe value of this object provides the state of the Tx 0 24 Volt supply voltage Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.35.2.1.98Columndualdrr2xminValueTx024Voltread-onlymandatoryThe value of this object provides the minimum value the Tx 0 24 Volt supply voltage Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.35.2.1.99Columndualdrr2xmaxValueTx024Voltread-onlymandatoryThe value of this object provides the maximum value the Tx 0 24 Volt supply voltage Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.35.2.1.100Columndualdrr2xalarmStateTx024Voltread-onlymandatoryThe value of this object provides the curent alarm state of the Tx 0 24 Volt supply voltage Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.101Columndualdrr2xlabelTx0ModTempread-onlyoptionalThe value of this object provides the label of the Tx 0 24 Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.102Columndualdrr2xuomTx0ModTempread-onlyoptionalThe value of this object provides the Unit of Measure of the Tx 0 Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.103Columndualdrr2xmajorHighTx0ModTempread-onlymandatoryThe value of this object provides the Major High alarm value of the Tx 0 Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.104Columndualdrr2xmajorLowTx0ModTempread-onlymandatoryThe value of this object provides the Major Low alarm value of the Tx 0 Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.105Columndualdrr2xminorHighTx0ModTempread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.35.2.1.106Columndualdrr2xminorLowTx0ModTempread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.35.2.1.107Columndualdrr2xcurrentValueTx0ModTempread-onlymandatoryThe value of this object provides the current value of the Tx 0 Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.108Columndualdrr2xstateFlagTx0ModTempread-onlymandatoryThe value of this object provides the state of the Tx 0 Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.35.2.1.109Columndualdrr2xminValueTx0ModTempread-onlymandatoryThe value of this object provides the minimum value the Tx 0 Module Temperature Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.35.2.1.110Columndualdrr2xmaxValueTx0ModTempread-onlymandatoryThe value of this object provides the maximum value the Tx 0 Module Temperature Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.35.2.1.111Columndualdrr2xalarmStateTx0ModTempread-onlymandatoryThe value of this object provides the curent alarm state of the Tx 0 Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.112Columndualdrr2xlabelTx1SFPWaveread-onlyoptionalThe value of this object provides the label of the Tx 1 SFP Wavelength Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.113Columndualdrr2xuomTx1SFPWaveread-onlyoptionalThe value of this object provides the Unit of Measure of the Tx 1 SFP Wavelength Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.114Columndualdrr2xmajorHighTx1SFPWaveread-onlymandatoryThe value of this object provides the Major High alarm value of the Tx 1 SFP Wavelength Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.115Columndualdrr2xmajorLowTx1SFPWaveread-onlymandatoryThe value of this object provides the Major Low alarm value of the Tx 1 SFP Wavelength Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.116Columndualdrr2xminorHighTx1SFPWaveread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.35.2.1.117Columndualdrr2xminorLowTx1SFPWaveread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.35.2.1.118Columndualdrr2xcurrentValueTx1SFPWaveread-onlymandatoryThe value of this object provides the current value of the Tx 1 SFP Wavelength Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.119Columndualdrr2xstateFlagTx1SFPWaveread-onlymandatoryThe value of this object provides the state of the Tx 1 SFP Wavelength Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.35.2.1.120Columndualdrr2xminValueTx1SFPWaveread-onlymandatoryThe value of this object provides the minimum value the Tx 1 SFP Wavelength Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.35.2.1.121Columndualdrr2xmaxValueTx1SFPWaveread-onlymandatoryThe value of this object provides the maximum value the Tx 1 SFP Wavelength Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.35.2.1.122Columndualdrr2xalarmStateTx1SFPWaveread-onlymandatoryThe value of this object provides the curent alarm state of the Tx 1 SFP Wavelength Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.123Columndualdrr2xlabelTx1OptPwrread-onlyoptionalThe value of this object provides the label of the Tx 1 Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.124Columndualdrr2xuomTx1OptPwrread-onlyoptionalThe value of this object provides the Unit of Measure of the Tx 1 Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.125Columndualdrr2xmajorHighTx1OptPwrread-onlymandatoryThe value of this object provides the Major High alarm value of the Tx 1 Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.126Columndualdrr2xmajorLowTx1OptPwrread-onlymandatoryThe value of this object provides the Major Low alarm value of the Tx 1 Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.127Columndualdrr2xminorHighTx1OptPwrread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.35.2.1.128Columndualdrr2xminorLowTx1OptPwrread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.35.2.1.129Columndualdrr2xcurrentValueTx1OptPwrread-onlymandatoryThe value of this object provides the current value of the Tx 1 Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.130Columndualdrr2xstateFlagTx1OptPwrread-onlymandatoryThe value of this object provides the state of the Tx 1 Optical Power Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.35.2.1.131Columndualdrr2xminValueTx1OptPwrread-onlymandatoryThe value of this object provides the minimum value the Tx 1 Optical Power Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.35.2.1.132Columndualdrr2xmaxValueTx1OptPwrread-onlymandatoryThe value of this object provides the maximum value the Tx 1 Optical Power Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.35.2.1.133Columndualdrr2xalarmStateTx1OptPwrread-onlymandatoryThe value of this object provides the curent alarm state of the Tx 1 Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.134Columndualdrr2xlabelTx124vCurrread-onlyoptionalThe value of this object provides the label of the Tx 1 24 VoltCurrent Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.135Columndualdrr2xuomTx124vCurrread-onlyoptionalThe value of this object provides the Unit of Measure of the Tx 1 24 Volt Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.136Columndualdrr2xmajorHighTx124vCurrread-onlymandatoryThe value of this object provides the Major High alarm value of the Tx 1 24 Volt Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.137Columndualdrr2xmajorLowTx124vCurrread-onlymandatoryThe value of this object provides the Major Low alarm value of the Tx 1 24 Volt Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.138Columndualdrr2xminorHighTx124vCurrread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.35.2.1.139Columndualdrr2xminorLowTx124vCurrread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.35.2.1.140Columndualdrr2xcurrentValueTx124vCurrread-onlymandatoryThe value of this object provides the current value of the Tx 1 24 Volt Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.141Columndualdrr2xstateFlagTx124vCurrread-onlymandatoryThe value of this object provides the state of the Tx 1 24 Volt Current Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.35.2.1.142Columndualdrr2xminValueTx124vCurrread-onlymandatoryThe value of this object provides the minimum value the Tx 1 24 Volt Current Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.35.2.1.143Columndualdrr2xmaxValueTx124vCurrread-onlymandatoryThe value of this object provides the maximum value the Tx 1 24 Volt Current Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.35.2.1.144Columndualdrr2xalarmStateTx124vCurrread-onlymandatoryThe value of this object provides the curent alarm state of the Tx 1 24 Volt Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.145Columndualdrr2xlabelTx124Voltread-onlyoptionalThe value of this object provides the label of the Tx 1 24 Volt supply voltage Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.146Columndualdrr2xuomTx124Voltread-onlyoptionalThe value of this object provides the Unit of Measure of the Tx 1 24 Volt supply voltage Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.147Columndualdrr2xmajorHighTx124Voltread-onlymandatoryThe value of this object provides the Major High alarm value of the Tx 1 24 Volt supply voltage Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.148Columndualdrr2xmajorLowTx124Voltread-onlymandatoryThe value of this object provides the Major Low alarm value of the Tx 1 24 Volt supply voltage Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.149Columndualdrr2xminorHighTx124Voltread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.35.2.1.150Columndualdrr2xminorLowTx124Voltread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.35.2.1.151Columndualdrr2xcurrentValueTx124Voltread-onlymandatoryThe value of this object provides the current value of the Tx 1 24 Volt supply voltage Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.152Columndualdrr2xstateFlagTx124Voltread-onlymandatoryThe value of this object provides the state of the Tx 1 24 Volt supply voltage Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.35.2.1.153Columndualdrr2xminValueTx124Voltread-onlymandatoryThe value of this object provides the minimum value the Tx 1 24 Volt supply voltage Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.35.2.1.154Columndualdrr2xmaxValueTx124Voltread-onlymandatoryThe value of this object provides the maximum value the Tx 1 24 Volt supply voltage Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.35.2.1.155Columndualdrr2xalarmStateTx124Voltread-onlymandatoryThe value of this object provides the curent alarm state of the Tx 1 24 Volt supply voltage Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.156Columndualdrr2xlabelTx1ModTempread-onlyoptionalThe value of this object provides the label of the Tx 1 24 Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.157Columndualdrr2xuomTx1ModTempread-onlyoptionalThe value of this object provides the Unit of Measure of the Tx 1 Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.158Columndualdrr2xmajorHighTx1ModTempread-onlymandatoryThe value of this object provides the Major High alarm value of the Tx 1 Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.159Columndualdrr2xmajorLowTx1ModTempread-onlymandatoryThe value of this object provides the Major Low alarm value of the Tx 1 Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.160Columndualdrr2xminorHighTx1ModTempread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.35.2.1.161Columndualdrr2xminorLowTx1ModTempread-onlyobsoleteThis object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
1.3.6.1.4.1.1166.6.1.2.35.2.1.162Columndualdrr2xcurrentValueTx1ModTempread-onlymandatoryThe value of this object provides the current value of the Tx 1 Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.2.1.163Columndualdrr2xstateFlagTx1ModTempread-onlymandatoryThe value of this object provides the state of the Tx 1 Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.35.2.1.164Columndualdrr2xminValueTx1ModTempread-onlymandatoryThe value of this object provides the minimum value the Tx 1 Module Temperature Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.35.2.1.165Columndualdrr2xmaxValueTx1ModTempread-onlymandatoryThe value of this object provides the maximum value the Tx 1 Module Temperature Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.35.2.1.166Columndualdrr2xalarmStateTx1ModTempread-onlymandatoryThe value of this object provides the curent alarm state of the Tx 1 Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.35.3Tablegx2dualdrr2xDigitalTablenot-accessiblemandatoryThis table contains gx2dualdrr2x specific digital parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.35.3Nodetrapdualdrr12VCurrentAlarmThis trap is issued when the 12V power supply Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this para…
1.3.6.1.4.1.1166.6.1.2.35.3.2Rowgx2dualdrr2xDigitalEntrynot-accessiblemandatoryThis list contains individual digital parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.35.3.2.1Columngx2dualdrr2xDigitalTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.35.3.2.2Columndualdrr2xlabelTrippoint1Valueread-onlyoptionalThe value of this object provides the label of the Trip point Value Digital parameter. The trip point Value defines the RF switch point based on the optical po…
1.3.6.1.4.1.1166.6.1.2.35.3.2.3Columndualdrr2xenumTrippoint1Valueread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
1.3.6.1.4.1.1166.6.1.2.35.3.2.4Columndualdrr2xvalueTrippoint1Valueread-writemandatoryThe value of this object reflects the setting of the threshold at which the Trip point activates. It is in 1 dB increments ranging from -25 to -5 dB. The user …
1.3.6.1.4.1.1166.6.1.2.35.3.2.5Columndualdrr2xstateflagTrippoint1Valueread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.35.3.2.6Columndualdrr2xlabelTrippoint1Moderead-onlyoptionalThe value of this object provides the label of the Trip point mode Digital parameter. The trip point mode defines the RF switch action based on the optical pow…
1.3.6.1.4.1.1166.6.1.2.35.3.2.7Columndualdrr2xenumTrippoint1Moderead-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
1.3.6.1.4.1.1166.6.1.2.35.3.2.8Columndualdrr2xvalueTrippoint1Moderead-writemandatoryThe value of this object is the current value of trip point mode. There are three possible value: 1-off, 2-alarm_only, 3-alarm&switch. If module input optical …
1.3.6.1.4.1.1166.6.1.2.35.3.2.9Columndualdrr2xstateflagTrippoint1Moderead-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.35.3.2.10Columndualdrr2xlabelTrippoint2Valueread-onlyoptionalThe value of this object provides the label of the Trip point Value Digital parameter. The trip point Value defines the RF switch point based on the optical po…
1.3.6.1.4.1.1166.6.1.2.35.3.2.11Columndualdrr2xenumTrippoint2Valueread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
1.3.6.1.4.1.1166.6.1.2.35.3.2.12Columndualdrr2xvalueTrippoint2Valueread-writemandatoryThe value of this object reflects the setting of the threshold at which the Trip point activates. It is in 1 dB increments ranging from -25 to -5 dB. The user …
1.3.6.1.4.1.1166.6.1.2.35.3.2.13Columndualdrr2xstateflagTrippoint2Valueread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.35.3.2.14Columndualdrr2xlabelTrippoint2Moderead-onlyoptionalThe value of this object provides the label of the Trip point mode Digital parameter. The trip point mode defines the RF switch action based on the optical pow…
1.3.6.1.4.1.1166.6.1.2.35.3.2.15Columndualdrr2xenumTrippoint2Moderead-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
1.3.6.1.4.1.1166.6.1.2.35.3.2.16Columndualdrr2xvalueTrippoint2Moderead-writemandatoryThe value of this object is the current value of trip point mode. There are three possible value: 1-off, 2-alarm_only, 3-alarm&switch. If module input optical …
1.3.6.1.4.1.1166.6.1.2.35.3.2.17Columndualdrr2xstateflagTrippoint2Moderead-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.35.3.2.18Columndualdrr2xlabelGainChannel1Aread-onlyoptionalThe value of this object provides the label of the RF Channel 1A Gain Digital parameter.
1.3.6.1.4.1.1166.6.1.2.35.3.2.19Columndualdrr2xenumGainChannel1Aread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
1.3.6.1.4.1.1166.6.1.2.35.3.2.20Columndualdrr2xvalueGainChannel1Aread-writemandatoryThe value of this object reflects the setting of the gain for RF Channel 1A. It is in 1 dB increments ranging from 0 to 20dB. The user can enter a number from …
1.3.6.1.4.1.1166.6.1.2.35.3.2.21Columndualdrr2xstateflagGainChannel1Aread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.35.3.2.22Columndualdrr2xlabelGainChannel1Bread-onlyoptionalThe value of this object provides the label of the RF Channel 1B Gain Digital parameter.
1.3.6.1.4.1.1166.6.1.2.35.3.2.23Columndualdrr2xenumGainChannel1Bread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
1.3.6.1.4.1.1166.6.1.2.35.3.2.24Columndualdrr2xvalueGainChannel1Bread-writemandatoryThe value of this object reflects the setting of the gain for RF Channel 1B. It is in 1 dB increments ranging from 0 to 20dB. The user can enter a number from …
1.3.6.1.4.1.1166.6.1.2.35.3.2.25Columndualdrr2xstateflagGainChannel1Bread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.35.3.2.26Columndualdrr2xlabelGainChannel2Aread-onlyoptionalThe value of this object provides the label of the RF Channel 2A Gain Digital parameter.
1.3.6.1.4.1.1166.6.1.2.35.3.2.27Columndualdrr2xenumGainChannel2Aread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
1.3.6.1.4.1.1166.6.1.2.35.3.2.28Columndualdrr2xvalueGainChannel2Aread-writemandatoryThe value of this object reflects the setting of the gain for RF Channel 2A. It is in 1 dB increments ranging from 0 to 20dB. The user can enter a number from …
1.3.6.1.4.1.1166.6.1.2.35.3.2.29Columndualdrr2xstateflagGainChannel2Aread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.35.3.2.30Columndualdrr2xlabelGainChannel2Bread-onlyoptionalThe value of this object provides the label of the RF Channel 2B Gain Digital parameter.
1.3.6.1.4.1.1166.6.1.2.35.3.2.31Columndualdrr2xenumGainChannel2Bread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
1.3.6.1.4.1.1166.6.1.2.35.3.2.32Columndualdrr2xvalueGainChannel2Bread-writemandatoryThe value of this object reflects the setting of the gain for RF Channel 2B. It is in 1 dB increments ranging from 0 to 20dB. The user can enter a number from …
1.3.6.1.4.1.1166.6.1.2.35.3.2.33Columndualdrr2xstateflagGainChannel2Bread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.35.3.2.34Columndualdrr2xlabelTestpointSelectread-onlyoptionalThe value of this object provides the label of the Module's test point select Digital parameter.
1.3.6.1.4.1.1166.6.1.2.35.3.2.35Columndualdrr2xenumTestpointSelectread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
1.3.6.1.4.1.1166.6.1.2.35.3.2.36Columndualdrr2xvalueTestpointSelectread-writemandatoryThe value of this object reflects the setting of the test point selector for The Module. The user can enter a number from 1 to 4
1.3.6.1.4.1.1166.6.1.2.35.3.2.37Columndualdrr2xstateflagTestpointSelectread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.35.3.2.38Columndualdrr2xlabelOpFrequencyread-onlyoptionalThe value of this object provides the label of the Module's active channels Digital parameter.
1.3.6.1.4.1.1166.6.1.2.35.3.2.39Columndualdrr2xenumOpFrequencyread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
1.3.6.1.4.1.1166.6.1.2.35.3.2.40Columndualdrr2xvalueOpFrequencyread-writemandatoryThe value of this object reflects which channels are active for The Module. The user can enter a number from 1 to 4
1.3.6.1.4.1.1166.6.1.2.35.3.2.41Columndualdrr2xstateflagOpFrequencyread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.35.3.2.42Columndualdrr2xlabelActChanSelectread-onlyoptionalThe value of this object provides the label of the Module's active channels Digital parameter.
1.3.6.1.4.1.1166.6.1.2.35.3.2.43Columndualdrr2xenumActChanSelectread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
1.3.6.1.4.1.1166.6.1.2.35.3.2.44Columndualdrr2xvalueActChanSelectread-writemandatoryThe value of this object reflects which channels are active for The Module. The user can enter a number from 1 to 4
1.3.6.1.4.1.1166.6.1.2.35.3.2.45Columndualdrr2xstateflagActChanSelectread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.35.3.2.46Columndualdrr2xlabelFactoryDefaultResetread-onlyoptionalThe value of this object provides the label of the Factory Default Reset Digital parameter.
1.3.6.1.4.1.1166.6.1.2.35.3.2.47Columndualdrr2xenumFactoryDefaultResetread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.35.3.2.48Columndualdrr2xvalueFactoryDefaultResetread-writemandatoryThe read of this value will return a invalid value. The read will not reflect the actual setting value for this parameter
1.3.6.1.4.1.1166.6.1.2.35.3.2.49Columndualdrr2xstateflagFactoryDefaultResetread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.35.4Tablegx2dualdrr2xStatusTablenot-accessiblemandatoryThis table contains gx2dualdrr2x specific status parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.35.4NodetrapdualdrrModuleTempAlarmThis trap is issued when the Internal Module Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.35.4.3Rowgx2dualdrr2xStatusEntrynot-accessiblemandatoryThis list contains Status parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.35.4.3.1Columngx2dualdrr2xStatusTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.35.4.3.2Columndualdrr2xlabelBootread-onlyoptionalThe value of this object provides the label of the Boot Status parameter.
1.3.6.1.4.1.1166.6.1.2.35.4.3.3Columndualdrr2xvalueBootread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.35.4.3.4Columndualdrr2xstateflagBootread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.35.4.3.5Columndualdrr2xlabelFlashread-onlyoptionalThe value of this object provides the label of the Flash Status parameter.
1.3.6.1.4.1.1166.6.1.2.35.4.3.6Columndualdrr2xvalueFlashread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.35.4.3.7Columndualdrr2xstateflagFlashread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.35.4.3.8Columndualdrr2xlabelFactoryDataCRCread-onlyoptionalThe value of this object provides the label of the Factory Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.35.4.3.9Columndualdrr2xvalueFactoryDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.35.4.3.10Columndualdrr2xstateflagFactoryDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.35.4.3.11Columndualdrr2xlabelAlarmDataCrcread-onlyoptionalThe value of this object provides the label of the Alarm Data Crc parameter.
1.3.6.1.4.1.1166.6.1.2.35.4.3.12Columndualdrr2xvalueAlarmDataCrcread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.35.4.3.13Columndualdrr2xstateflagAlarmDataCrcread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.35.4.3.14Columndualdrr2xlabelCalibrationDataCrcread-onlyoptionalThe value of this object provides the label of the Calibration Data Crc parameter.
1.3.6.1.4.1.1166.6.1.2.35.4.3.15Columndualdrr2xvalueCalibrationDataCrcread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.35.4.3.16Columndualdrr2xstateflagCalibrationDataCrcread-onlymandatoryThe value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.35.4.3.17Columndualdrr2xlabelHardwareStatusread-onlyoptionalThe value of this object provides the label of the Module Hardware Status parameter.
1.3.6.1.4.1.1166.6.1.2.35.4.3.18Columndualdrr2xvalueHardwareStatusread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.35.4.3.19Columndualdrr2xstateflagHardwareStatusread-onlymandatoryThe value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.35.4.3.20Columndualdrr2xlabelCh1TripPointStatusread-onlyoptionalThe value of this object provides the label of the Optical Trip Point Status parameter.It indicates whether the optical power is above(0) or below(1) trip poin…
1.3.6.1.4.1.1166.6.1.2.35.4.3.21Columndualdrr2xvalueCh1TripPointStatusread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.35.4.3.22Columndualdrr2xstateflagCh1TripPointStatusread-onlymandatoryThe value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.35.4.3.23Columndualdrr2xlabelLink1Statusread-onlyoptionalThe value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect t…
1.3.6.1.4.1.1166.6.1.2.35.4.3.24Columndualdrr2xvalueLink1Statusread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.35.4.3.25Columndualdrr2xstateflagLink1Statusread-onlymandatoryThe value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.35.4.3.26Columndualdrr2xlabelCh2TripPointStatusread-onlyoptionalThe value of this object provides the label of the Optical Trip Point Status parameter.It indicates whether the optical power is above(0) or below(1) trip poin…
1.3.6.1.4.1.1166.6.1.2.35.4.3.27Columndualdrr2xvalueCh2TripPointStatusread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.35.4.3.28Columndualdrr2xstateflagCh2TripPointStatusread-onlymandatoryThe value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.35.4.3.29Columndualdrr2xlabelLink2Statusread-onlyoptionalThe value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect t…
1.3.6.1.4.1.1166.6.1.2.35.4.3.30Columndualdrr2xvalueLink2Statusread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.35.4.3.31Columndualdrr2xstateflagLink2Statusread-onlymandatoryThe value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.35.4.3.32Columndualdrr2xlabelDRT1Statusread-onlyoptionalThe value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect t…
1.3.6.1.4.1.1166.6.1.2.35.4.3.33Columndualdrr2xvalueDRT1Statusread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.35.4.3.34Columndualdrr2xstateflagDRT1Statusread-onlymandatoryThe value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.35.4.3.35Columndualdrr2xlabelSFP0Statusread-onlyoptionalThe value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect t…
1.3.6.1.4.1.1166.6.1.2.35.4.3.36Columndualdrr2xvalueSFP0Statusread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.35.4.3.37Columndualdrr2xstateflagSFP0Statusread-onlymandatoryThe value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.35.4.3.38Columndualdrr2xlabelDRT2Statusread-onlyoptionalThe value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect t…
1.3.6.1.4.1.1166.6.1.2.35.4.3.39Columndualdrr2xvalueDRT2Statusread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.35.4.3.40Columndualdrr2xstateflagDRT2Statusread-onlymandatoryThe value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.35.4.3.41Columndualdrr2xlabelSFP1Statusread-onlyoptionalThe value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect t…
1.3.6.1.4.1.1166.6.1.2.35.4.3.42Columndualdrr2xvalueSFP1Statusread-onlymandatoryThe value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
1.3.6.1.4.1.1166.6.1.2.35.4.3.43Columndualdrr2xstateflagSFP1Statusread-onlymandatoryThe value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
1.3.6.1.4.1.1166.6.1.2.35.5Tablegx2dualdrr2xFactoryTablenot-accessiblemandatoryThis table contains gx2dualdrr2x specific factory setting parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.35.5NodetrapdualdrrFanSpeedAlarmThis trap is issued when the Fan Speed parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.35.5.4Rowgx2dualdrr2xFactoryEntrynot-accessiblemandatoryThis list contains Factory setting parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.35.5.4.1Columngx2dualdrr2xFactoryTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.35.5.4.2Columndualdrr2xbootControlByteread-onlymandatoryThe value of this object indicates which bank the firmware is currently being boot from.
1.3.6.1.4.1.1166.6.1.2.35.5.4.3Columndualdrr2xbootStatusByteread-onlymandatoryThis object indicates the status of the last boot
1.3.6.1.4.1.1166.6.1.2.35.5.4.4Columndualdrr2xbank1CRCread-onlymandatoryThis object provides the CRC code of bank 0.
1.3.6.1.4.1.1166.6.1.2.35.5.4.5Columndualdrr2xbank2CRCread-onlymandatoryThis object provides the CRC code of bank 1.
1.3.6.1.4.1.1166.6.1.2.35.5.4.6Columndualdrr2xprgEEPROMByteread-onlymandatoryThis object indicates if the EEPROM has been programmed
1.3.6.1.4.1.1166.6.1.2.35.5.4.7Columndualdrr2xfactoryCRCread-onlymandatoryThis object provides the CRC code for the Factory data.
1.3.6.1.4.1.1166.6.1.2.35.5.4.8Columndualdrr2xcalculateCRCread-onlymandatoryThis object indicates which of the Emnums will have the CRC calculated (1-factory, 2-alarm, 3-calibration).
1.3.6.1.4.1.1166.6.1.2.35.5.4.9Columndualdrr2xhourMeterread-onlymandatoryThis object provides the hour meter reading of the module.
1.3.6.1.4.1.1166.6.1.2.35.5.4.10Columndualdrr2xflashPrgCntAread-onlymandatoryThis object provides the number of times Bank 0 flash has been programmed.
1.3.6.1.4.1.1166.6.1.2.35.5.4.11Columndualdrr2xflashPrgCntBread-onlymandatoryThis object provides the number of times Bank 1 flash has been programmed.
1.3.6.1.4.1.1166.6.1.2.35.5.4.12Columndualdrr2xflashBankARevread-onlymandatoryThis object provides the revision of flash bank 0.
1.3.6.1.4.1.1166.6.1.2.35.5.4.13Columndualdrr2xflashBankBRevread-onlymandatoryThis object provides the revision of flash bank 1.
1.3.6.1.4.1.1166.6.1.2.35.5.4.14Columndualdrr2xSubAgentRevread-onlymandatoryThis object provides the subagent revision of receiver module.
1.3.6.1.4.1.1166.6.1.2.35.5.4.15Columndualdrr2xFPGA0FwRevread-onlymandatoryThis object provides the Firmware revision of the first DRR FPGA.
1.3.6.1.4.1.1166.6.1.2.35.5.4.16Columndualdrr2xFPGA1FwRevread-onlymandatoryThis object provides the Firmware revision of the second DRR FPGA.
1.3.6.1.4.1.1166.6.1.2.35.5.4.17Columndualdrr2xDRT1SerialNoread-onlymandatoryThis object provides the Serial Number of the DRT attached to channel 1.
1.3.6.1.4.1.1166.6.1.2.35.5.4.18Columndualdrr2xDRT1SFPSerialNoread-onlymandatoryThis object provides the Serial Number of the SFP in the DRT attached to channel 1.
1.3.6.1.4.1.1166.6.1.2.35.5.4.19Columndualdrr2xDRT1SFPPartNoread-onlymandatoryThis object provides the Part number of the SFP in the DRT attached to channel 1.
1.3.6.1.4.1.1166.6.1.2.35.5.4.20Columndualdrr2xDRT1FwRevread-onlymandatoryThis object provides the Firmware revision of the DRT attached to channel 1.
1.3.6.1.4.1.1166.6.1.2.35.5.4.21Columndualdrr2xDRT1FpgaFwRevread-onlymandatoryThis object provides the Firmware revision of the FPGA in the DRT attached to channel 1.
1.3.6.1.4.1.1166.6.1.2.35.5.4.22Columndualdrr2xDRT2SerialNoread-onlymandatoryThis object provides the Serial Number of the DRT attached to channel 2
1.3.6.1.4.1.1166.6.1.2.35.5.4.23Columndualdrr2xDRT2SFPSerialNoread-onlymandatoryThis object provides the Serial Number of the SFP in the DRT attached to channel 2
1.3.6.1.4.1.1166.6.1.2.35.5.4.24Columndualdrr2xDRT2SFPPartNoread-onlymandatoryThis object provides the Part number of the SFP in the DRT attached to channel 2.
1.3.6.1.4.1.1166.6.1.2.35.5.4.25Columndualdrr2xDRT2FwRevread-onlymandatoryThis object provides the Firmware revision of the DRT attached to channel 2.
1.3.6.1.4.1.1166.6.1.2.35.5.4.26Columndualdrr2xDRT2FpgaFwRevread-onlymandatoryThis object provides the Firmware revision of the FPGA in the DRT attached to channel 2.
1.3.6.1.4.1.1166.6.1.2.35.6NodetrapdualdrrFlashAlarmThis trap is issued when the detects an error during Flash memory operations.
1.3.6.1.4.1.1166.6.1.2.35.7NodetrapdualdrrBankBootAlarmThis trap is issued when the module detects an error while booting from bank 0 or bank 1.
1.3.6.1.4.1.1166.6.1.2.35.8NodetrapdualdrrAlarmDataCRCAlarmThis trap is issued when the Alarm Data CRC is incorrect.
1.3.6.1.4.1.1166.6.1.2.35.9NodetrapdualdrrHardwareErrAlarmThis trap is issued when hardware is abnormal.
1.3.6.1.4.1.1166.6.1.2.35.10NodetrapdualdrrOpticalSignal1AlarmThis trap is issued when the optical signal 1 is beyond the preset range.
1.3.6.1.4.1.1166.6.1.2.35.11NodetrapdualdrrOpticalSignal2AlarmThis trap is issued when the optical signal 2 is beyond the preset range.
1.3.6.1.4.1.1166.6.1.2.35.12NodetrapdualdrrFactoryDataCRCAlarmThis trap is issued when the Factory Data CRC is incorrect.
1.3.6.1.4.1.1166.6.1.2.35.13NodetrapdualdrrResetFactoryDefaultAlarmThis trap is issued when the Factory Default Reset occurs.
1.3.6.1.4.1.1166.6.1.2.35.14NodetrapdualdrrTripPoint1AlarmThis trap is issued when the Input 1 optical power is lower than the custumer set trip point and trippoint mode as ALARM_ONLY or SWITCH & ALARM.
1.3.6.1.4.1.1166.6.1.2.35.15NodetrapdualdrrTripPoint2AlarmThis trap is issued when the Input 2 optical power is lower than the custumer set trip point and trippoint mode as ALARM_ONLY or SWITCH & ALARM.
1.3.6.1.4.1.1166.6.1.2.35.16NodetrapdualdrrLink1AlarmThis trap is issued when receiver 1 is out of SYN with transmitter
1.3.6.1.4.1.1166.6.1.2.35.17NodetrapdualdrrLink2AlarmThis trap is issued when receiver 2 is out of SYN with transmitter
1.3.6.1.4.1.1166.6.1.2.35.18NodetrapdualdrrCalibrationDataCRCAlarmThis trap is issued when the Calibration Data CRC is incorrect
1.3.6.1.4.1.1166.6.1.2.35.19NodetrapdualdrrSFP1OptPWRAlarmThis trap is issued when SFP 1's optical power is incorrect
1.3.6.1.4.1.1166.6.1.2.35.20NodetrapdualdrrDRT1Cur24VAlarmThis trap is issued when DRT 1's 24 volt current is incorrect
1.3.6.1.4.1.1166.6.1.2.35.21NodetrapdualdrrDRT1ModTempAarmThis trap is issued when DRT 1's Module telperature is incorrect
1.3.6.1.4.1.1166.6.1.2.35.22NodetrapdualdrrSFP2OptPWRAlarmThis trap is issued when SFP 2's optical power is incorrect
1.3.6.1.4.1.1166.6.1.2.35.23NodetrapdualdrrDRT2Cur24VAlarmThis trap is issued when DRT 2's 24 volt current is incorrect
1.3.6.1.4.1.1166.6.1.2.35.24NodetrapdualdrrDRT2ModTempAarmThis trap is issued when DRT 2's Module telperature is incorrect