OPTIX-SONET-PER-MIB
61 objects
Description.
Imported Objects
| OPTIX-OID-MIB | optixCommonSonet |
| OPTIX-SONET-TC-MIB | DirectionType LocationType MOD2Type PerformanceEventType ValidflagType |
| SNMPv2-CONF | MODULE-COMPLIANCE OBJECT-GROUP |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DateAndTime |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.2.1.10.3.20.20 | IdentityoptixSonetPerformance | Description. | ||
| 1.3.6.1.2.1.10.3.20.20.10 | NodepmData | |||
| 1.3.6.1.2.1.10.3.20.20.10.10 | Tableper15mCurDataTable | not-accessible | current | instructs an NE to send its current set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE. |
| 1.3.6.1.2.1.10.3.20.20.10.10.1 | Rowper15mCurDataEntry | not-accessible | current | instructs an NE to send its current set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE. |
| 1.3.6.1.2.1.10.3.20.20.10.10.1.1 | Columnpm15mCurDataMOD2 | read-only | current | Signal mode. |
| 1.3.6.1.2.1.10.3.20.20.10.10.1.2 | Columnpm15mCurDataSlot | read-only | current | Slot number. This will indicate what is the slot of the object which raised this PM data. If not relevant to the PM data, will be zero. |
| 1.3.6.1.2.1.10.3.20.20.10.10.1.3 | Columnpm15mCurDataPort | read-only | current | Port number. This will indicate what is the Port of the object which raised this PM data. If not relevant to the PM data, will be zero. |
| 1.3.6.1.2.1.10.3.20.20.10.10.1.4 | Columnpm15mCurDataPath | read-only | current | Path number. This will indicate what is the Path of the object which raised this PM data. If not relevant to the PM data, will be zero. |
| 1.3.6.1.2.1.10.3.20.20.10.10.1.5 | Columnpm15mCurDataVT | read-only | current | VT path number. This will indicate what is the VT path of the object which raised this PM data. If not relevant to the PM data, will be zero. |
| 1.3.6.1.2.1.10.3.20.20.10.10.1.6 | Columnpm15mCurDataName | read-only | current | Indicates the type of monitored parameter for which a value is retrieved. |
| 1.3.6.1.2.1.10.3.20.20.10.10.1.7 | Columnpm15mCurDataLocation | read-only | current | Indicates the location. Only NEND(Near end)|FEND(Far end)|ALL will be represented here. |
| 1.3.6.1.2.1.10.3.20.20.10.10.1.8 | Columnpm15mCurDataDirection | read-only | current | specifies the direction of monitoring. Only RCV(Receive direction)|TRMT(Transmit direction)|ALL will be represented here. |
| 1.3.6.1.2.1.10.3.20.20.10.10.1.9 | Columnpm15mCurDataMonVal | read-only | current | Measured value. |
| 1.3.6.1.2.1.10.3.20.20.10.10.1.10 | Columnpm15mCurDataVldty | read-only | current | It indicates whether the information for the specified time period was accumulated over the entire time period or some portion of it. Only INVALID|VALID will b… |
| 1.3.6.1.2.1.10.3.20.20.10.10.1.11 | Columnpm15mCurDataStartTime | read-only | current | The beginning date and time of the PM period. |
| 1.3.6.1.2.1.10.3.20.20.10.20 | Tableper15mHisDataTable | not-accessible | current | instructs an NE to send its history set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE. |
| 1.3.6.1.2.1.10.3.20.20.10.20.1 | Rowper15mHisDataEntry | not-accessible | current | instructs an NE to send its history set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE. |
| 1.3.6.1.2.1.10.3.20.20.10.20.1.1 | Columnpm15mHisDataMOD2 | read-only | current | Signal mode. |
| 1.3.6.1.2.1.10.3.20.20.10.20.1.2 | Columnpm15mHisDataSlot | read-only | current | Slot number. This will indicate what is the slot of the object which raised this PM data. If not relevant to the PM data, will be zero. |
| 1.3.6.1.2.1.10.3.20.20.10.20.1.3 | Columnpm15mHisDataPort | read-only | current | Port number. This will indicate what is the Port of the object which raised this PM data. If not relevant to the PM data, will be zero. |
| 1.3.6.1.2.1.10.3.20.20.10.20.1.4 | Columnpm15mHisDataPath | read-only | current | Path number. This will indicate what is the Path of the object which raised this PM data. If not relevant to the PM data, will be zero. |
| 1.3.6.1.2.1.10.3.20.20.10.20.1.5 | Columnpm15mHisDataVT | read-only | current | VT path number. This will indicate what is the VT path of the object which raised this PM data. If not relevant to the PM data, will be zero. |
| 1.3.6.1.2.1.10.3.20.20.10.20.1.6 | Columnpm15mHisDataName | read-only | current | Indicates the type of monitored parameter for which a value is retrieved. |
| 1.3.6.1.2.1.10.3.20.20.10.20.1.7 | Columnpm15mHisDataLocation | read-only | current | Indicates the location. Only NEND(Near end)|FEND(Far end)|ALL will be represented here. |
| 1.3.6.1.2.1.10.3.20.20.10.20.1.8 | Columnpm15mHisDataDirection | read-only | current | Specifies the direction of monitoring. Only RCV(Receive direction)|TRMT(Transmit direction)|ALL will be represented here. |
| 1.3.6.1.2.1.10.3.20.20.10.20.1.9 | Columnpm15mHisDataInterval | read-only | current | The period number. |
| 1.3.6.1.2.1.10.3.20.20.10.20.1.10 | Columnpm15mHisDataMonVal | read-only | current | Measured value. |
| 1.3.6.1.2.1.10.3.20.20.10.20.1.11 | Columnpm15mHisDataVldty | read-only | current | It indicates whether the information for the specified time period was accumulated over the entire time period or some portion of it. Only INVALID|VALID will b… |
| 1.3.6.1.2.1.10.3.20.20.10.20.1.12 | Columnpm15mHisDataStartTime | read-only | current | The beginning date and time of the PM period. |
| 1.3.6.1.2.1.10.3.20.20.10.30 | Tableper1dayCurDataTable | not-accessible | current | instructs an NE to send its current set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE. |
| 1.3.6.1.2.1.10.3.20.20.10.30.1 | Rowper1dayCurDataEntry | not-accessible | current | instructs an NE to send its current set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE. |
| 1.3.6.1.2.1.10.3.20.20.10.30.1.1 | Columnpm1dayCurDataMOD2 | read-only | current | Signal mode. |
| 1.3.6.1.2.1.10.3.20.20.10.30.1.2 | Columnpm1dayCurDataSlot | read-only | current | Slot number. This will indicate what is the slot of the object which raised this PM data. If not relevant to the PM data, will be zero. |
| 1.3.6.1.2.1.10.3.20.20.10.30.1.3 | Columnpm1dayCurDataPort | read-only | current | Port number. This will indicate what is the Port of the object which raised this PM data. If not relevant to the PM data, will be zero. |
| 1.3.6.1.2.1.10.3.20.20.10.30.1.4 | Columnpm1dayCurDataPath | read-only | current | Path number. This will indicate what is the Path of the object which raised this PM data. If not relevant to the PM data, will be zero. |
| 1.3.6.1.2.1.10.3.20.20.10.30.1.5 | Columnpm1dayCurDataVT | read-only | current | VT path number. This will indicate what is the VT path of the object which raised this PM data. If not relevant to the PM data, will be zero. |
| 1.3.6.1.2.1.10.3.20.20.10.30.1.6 | Columnpm1dayCurDataName | read-only | current | Indicates the type of monitored parameter for which a value is retrieved. |
| 1.3.6.1.2.1.10.3.20.20.10.30.1.7 | Columnpm1dayCurDataLocation | read-only | current | Indicates the location. Only NEND(Near end)|FEND(Far end)|ALL will be represented here. |
| 1.3.6.1.2.1.10.3.20.20.10.30.1.8 | Columnpm1dayCurDataDirection | read-only | current | Specifies the direction of monitoring. Only RCV(Receive direction)|TRMT(Transmit direction)|ALL will be represented here. |
| 1.3.6.1.2.1.10.3.20.20.10.30.1.9 | Columnpm1dayCurDataMonVal | read-only | current | measured value. |
| 1.3.6.1.2.1.10.3.20.20.10.30.1.10 | Columnpm1dayCurDataVldty | read-only | current | It indicates whether the information for the specified time period was accumulated over the entire time period or some portion of it. Only INVALID|VALID will b… |
| 1.3.6.1.2.1.10.3.20.20.10.30.1.11 | Columnpm1dayCurDataStartTime | read-only | current | The beginning date and time of the PM period. |
| 1.3.6.1.2.1.10.3.20.20.10.40 | Tableper1dayHisDataTable | not-accessible | current | instructs an NE to send its history set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE. |
| 1.3.6.1.2.1.10.3.20.20.10.40.1 | Rowper1dayHisDataEntry | not-accessible | current | instructs an NE to send its history set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE. |
| 1.3.6.1.2.1.10.3.20.20.10.40.1.1 | Columnpm1dayHisDataMOD2 | read-only | current | Signal mode. |
| 1.3.6.1.2.1.10.3.20.20.10.40.1.2 | Columnpm1dayHisDataSlot | read-only | current | Slot number. This will indicate what is the slot of the object which raised this PM data. If not relevant to the PM data, will be zero. |
| 1.3.6.1.2.1.10.3.20.20.10.40.1.3 | Columnpm1dayHisDataPort | read-only | current | Port number. This will indicate what is the Port of the object which raised this PM data. If not relevant to the PM data, will be zero. |
| 1.3.6.1.2.1.10.3.20.20.10.40.1.4 | Columnpm1dayHisDataPath | read-only | current | Path number. This will indicate what is the Path of the object which raised this PM data. If not relevant to the PM data, will be zero. |
| 1.3.6.1.2.1.10.3.20.20.10.40.1.5 | Columnpm1dayHisDataVT | read-only | current | VT path number. This will indicate what is the VT path of the object which raised this PM data. If not relevant to the PM data, will be zero. |
| 1.3.6.1.2.1.10.3.20.20.10.40.1.6 | Columnpm1dayHisDataName | read-only | current | Indicates the type of monitored parameter for which a value is retrieved. |
| 1.3.6.1.2.1.10.3.20.20.10.40.1.7 | Columnpm1dayHisDataLocation | read-only | current | Indicates the location. Only NEND(Near end)|FEND(Far end)|ALL will be represented here. |
| 1.3.6.1.2.1.10.3.20.20.10.40.1.8 | Columnpm1dayHisDataDirection | read-only | current | Specifies the direction of monitoring. Only RCV(Receive direction)|TRMT(Transmit direction)|ALL will be represented here. |
| 1.3.6.1.2.1.10.3.20.20.10.40.1.9 | Columnpm1dayHisDataInterval | read-only | current | The period number. |
| 1.3.6.1.2.1.10.3.20.20.10.40.1.10 | Columnpm1dayHisDataMonVal | read-only | current | Measured value. |
| 1.3.6.1.2.1.10.3.20.20.10.40.1.11 | Columnpm1dayHisDataVldty | read-only | current | It indicates whether the information for the specified time period was accumulated over the entire time period or some portion of it. Only INVALID|VALID will b… |
| 1.3.6.1.2.1.10.3.20.20.10.40.1.12 | Columnpm1dayHisDataStartTime | read-only | current | The beginning date and time of the PM period. |
| 1.3.6.1.2.1.10.3.20.20.20 | NodeoptixSonetPmConformance | |||
| 1.3.6.1.2.1.10.3.20.20.20.1 | NodeoptixSonetPmGroups | |||
| 1.3.6.1.2.1.10.3.20.20.20.1.1 | GroupoptixSonetPmObjectGroup | current | Enter the description of the created OBJECT-GROUP. | |
| 1.3.6.1.2.1.10.3.20.20.20.2 | NodeoptixSonetPmCompliances | |||
| 1.3.6.1.2.1.10.3.20.20.20.2.1 | ComplianceoptixSonetPmBasicCompliance | current | Enter the description of the created MODULE-COMPLIANCE. |