MIB Viewer

OPTIX-SONET-PER-MIB

61 objects
Description.
OIDNameAccessStatusDescription
1.3.6.1.2.1.10.3.20.20IdentityoptixSonetPerformanceDescription.
1.3.6.1.2.1.10.3.20.20.10NodepmData
1.3.6.1.2.1.10.3.20.20.10.10Tableper15mCurDataTablenot-accessiblecurrentinstructs an NE to send its current set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE.
1.3.6.1.2.1.10.3.20.20.10.10.1Rowper15mCurDataEntrynot-accessiblecurrentinstructs an NE to send its current set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE.
1.3.6.1.2.1.10.3.20.20.10.10.1.1Columnpm15mCurDataMOD2read-onlycurrentSignal mode.
1.3.6.1.2.1.10.3.20.20.10.10.1.2Columnpm15mCurDataSlotread-onlycurrentSlot number. This will indicate what is the slot of the object which raised this PM data. If not relevant to the PM data, will be zero.
1.3.6.1.2.1.10.3.20.20.10.10.1.3Columnpm15mCurDataPortread-onlycurrentPort number. This will indicate what is the Port of the object which raised this PM data. If not relevant to the PM data, will be zero.
1.3.6.1.2.1.10.3.20.20.10.10.1.4Columnpm15mCurDataPathread-onlycurrentPath number. This will indicate what is the Path of the object which raised this PM data. If not relevant to the PM data, will be zero.
1.3.6.1.2.1.10.3.20.20.10.10.1.5Columnpm15mCurDataVTread-onlycurrentVT path number. This will indicate what is the VT path of the object which raised this PM data. If not relevant to the PM data, will be zero.
1.3.6.1.2.1.10.3.20.20.10.10.1.6Columnpm15mCurDataNameread-onlycurrentIndicates the type of monitored parameter for which a value is retrieved.
1.3.6.1.2.1.10.3.20.20.10.10.1.7Columnpm15mCurDataLocationread-onlycurrentIndicates the location. Only NEND(Near end)|FEND(Far end)|ALL will be represented here.
1.3.6.1.2.1.10.3.20.20.10.10.1.8Columnpm15mCurDataDirectionread-onlycurrentspecifies the direction of monitoring. Only RCV(Receive direction)|TRMT(Transmit direction)|ALL will be represented here.
1.3.6.1.2.1.10.3.20.20.10.10.1.9Columnpm15mCurDataMonValread-onlycurrentMeasured value.
1.3.6.1.2.1.10.3.20.20.10.10.1.10Columnpm15mCurDataVldtyread-onlycurrentIt indicates whether the information for the specified time period was accumulated over the entire time period or some portion of it. Only INVALID|VALID will b…
1.3.6.1.2.1.10.3.20.20.10.10.1.11Columnpm15mCurDataStartTimeread-onlycurrentThe beginning date and time of the PM period.
1.3.6.1.2.1.10.3.20.20.10.20Tableper15mHisDataTablenot-accessiblecurrentinstructs an NE to send its history set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE.
1.3.6.1.2.1.10.3.20.20.10.20.1Rowper15mHisDataEntrynot-accessiblecurrentinstructs an NE to send its history set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE.
1.3.6.1.2.1.10.3.20.20.10.20.1.1Columnpm15mHisDataMOD2read-onlycurrentSignal mode.
1.3.6.1.2.1.10.3.20.20.10.20.1.2Columnpm15mHisDataSlotread-onlycurrentSlot number. This will indicate what is the slot of the object which raised this PM data. If not relevant to the PM data, will be zero.
1.3.6.1.2.1.10.3.20.20.10.20.1.3Columnpm15mHisDataPortread-onlycurrentPort number. This will indicate what is the Port of the object which raised this PM data. If not relevant to the PM data, will be zero.
1.3.6.1.2.1.10.3.20.20.10.20.1.4Columnpm15mHisDataPathread-onlycurrentPath number. This will indicate what is the Path of the object which raised this PM data. If not relevant to the PM data, will be zero.
1.3.6.1.2.1.10.3.20.20.10.20.1.5Columnpm15mHisDataVTread-onlycurrentVT path number. This will indicate what is the VT path of the object which raised this PM data. If not relevant to the PM data, will be zero.
1.3.6.1.2.1.10.3.20.20.10.20.1.6Columnpm15mHisDataNameread-onlycurrentIndicates the type of monitored parameter for which a value is retrieved.
1.3.6.1.2.1.10.3.20.20.10.20.1.7Columnpm15mHisDataLocationread-onlycurrentIndicates the location. Only NEND(Near end)|FEND(Far end)|ALL will be represented here.
1.3.6.1.2.1.10.3.20.20.10.20.1.8Columnpm15mHisDataDirectionread-onlycurrentSpecifies the direction of monitoring. Only RCV(Receive direction)|TRMT(Transmit direction)|ALL will be represented here.
1.3.6.1.2.1.10.3.20.20.10.20.1.9Columnpm15mHisDataIntervalread-onlycurrentThe period number.
1.3.6.1.2.1.10.3.20.20.10.20.1.10Columnpm15mHisDataMonValread-onlycurrentMeasured value.
1.3.6.1.2.1.10.3.20.20.10.20.1.11Columnpm15mHisDataVldtyread-onlycurrentIt indicates whether the information for the specified time period was accumulated over the entire time period or some portion of it. Only INVALID|VALID will b…
1.3.6.1.2.1.10.3.20.20.10.20.1.12Columnpm15mHisDataStartTimeread-onlycurrentThe beginning date and time of the PM period.
1.3.6.1.2.1.10.3.20.20.10.30Tableper1dayCurDataTablenot-accessiblecurrentinstructs an NE to send its current set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE.
1.3.6.1.2.1.10.3.20.20.10.30.1Rowper1dayCurDataEntrynot-accessiblecurrentinstructs an NE to send its current set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE.
1.3.6.1.2.1.10.3.20.20.10.30.1.1Columnpm1dayCurDataMOD2read-onlycurrentSignal mode.
1.3.6.1.2.1.10.3.20.20.10.30.1.2Columnpm1dayCurDataSlotread-onlycurrentSlot number. This will indicate what is the slot of the object which raised this PM data. If not relevant to the PM data, will be zero.
1.3.6.1.2.1.10.3.20.20.10.30.1.3Columnpm1dayCurDataPortread-onlycurrentPort number. This will indicate what is the Port of the object which raised this PM data. If not relevant to the PM data, will be zero.
1.3.6.1.2.1.10.3.20.20.10.30.1.4Columnpm1dayCurDataPathread-onlycurrentPath number. This will indicate what is the Path of the object which raised this PM data. If not relevant to the PM data, will be zero.
1.3.6.1.2.1.10.3.20.20.10.30.1.5Columnpm1dayCurDataVTread-onlycurrentVT path number. This will indicate what is the VT path of the object which raised this PM data. If not relevant to the PM data, will be zero.
1.3.6.1.2.1.10.3.20.20.10.30.1.6Columnpm1dayCurDataNameread-onlycurrentIndicates the type of monitored parameter for which a value is retrieved.
1.3.6.1.2.1.10.3.20.20.10.30.1.7Columnpm1dayCurDataLocationread-onlycurrentIndicates the location. Only NEND(Near end)|FEND(Far end)|ALL will be represented here.
1.3.6.1.2.1.10.3.20.20.10.30.1.8Columnpm1dayCurDataDirectionread-onlycurrentSpecifies the direction of monitoring. Only RCV(Receive direction)|TRMT(Transmit direction)|ALL will be represented here.
1.3.6.1.2.1.10.3.20.20.10.30.1.9Columnpm1dayCurDataMonValread-onlycurrentmeasured value.
1.3.6.1.2.1.10.3.20.20.10.30.1.10Columnpm1dayCurDataVldtyread-onlycurrentIt indicates whether the information for the specified time period was accumulated over the entire time period or some portion of it. Only INVALID|VALID will b…
1.3.6.1.2.1.10.3.20.20.10.30.1.11Columnpm1dayCurDataStartTimeread-onlycurrentThe beginning date and time of the PM period.
1.3.6.1.2.1.10.3.20.20.10.40Tableper1dayHisDataTablenot-accessiblecurrentinstructs an NE to send its history set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE.
1.3.6.1.2.1.10.3.20.20.10.40.1Rowper1dayHisDataEntrynot-accessiblecurrentinstructs an NE to send its history set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE.
1.3.6.1.2.1.10.3.20.20.10.40.1.1Columnpm1dayHisDataMOD2read-onlycurrentSignal mode.
1.3.6.1.2.1.10.3.20.20.10.40.1.2Columnpm1dayHisDataSlotread-onlycurrentSlot number. This will indicate what is the slot of the object which raised this PM data. If not relevant to the PM data, will be zero.
1.3.6.1.2.1.10.3.20.20.10.40.1.3Columnpm1dayHisDataPortread-onlycurrentPort number. This will indicate what is the Port of the object which raised this PM data. If not relevant to the PM data, will be zero.
1.3.6.1.2.1.10.3.20.20.10.40.1.4Columnpm1dayHisDataPathread-onlycurrentPath number. This will indicate what is the Path of the object which raised this PM data. If not relevant to the PM data, will be zero.
1.3.6.1.2.1.10.3.20.20.10.40.1.5Columnpm1dayHisDataVTread-onlycurrentVT path number. This will indicate what is the VT path of the object which raised this PM data. If not relevant to the PM data, will be zero.
1.3.6.1.2.1.10.3.20.20.10.40.1.6Columnpm1dayHisDataNameread-onlycurrentIndicates the type of monitored parameter for which a value is retrieved.
1.3.6.1.2.1.10.3.20.20.10.40.1.7Columnpm1dayHisDataLocationread-onlycurrentIndicates the location. Only NEND(Near end)|FEND(Far end)|ALL will be represented here.
1.3.6.1.2.1.10.3.20.20.10.40.1.8Columnpm1dayHisDataDirectionread-onlycurrentSpecifies the direction of monitoring. Only RCV(Receive direction)|TRMT(Transmit direction)|ALL will be represented here.
1.3.6.1.2.1.10.3.20.20.10.40.1.9Columnpm1dayHisDataIntervalread-onlycurrentThe period number.
1.3.6.1.2.1.10.3.20.20.10.40.1.10Columnpm1dayHisDataMonValread-onlycurrentMeasured value.
1.3.6.1.2.1.10.3.20.20.10.40.1.11Columnpm1dayHisDataVldtyread-onlycurrentIt indicates whether the information for the specified time period was accumulated over the entire time period or some portion of it. Only INVALID|VALID will b…
1.3.6.1.2.1.10.3.20.20.10.40.1.12Columnpm1dayHisDataStartTimeread-onlycurrentThe beginning date and time of the PM period.
1.3.6.1.2.1.10.3.20.20.20NodeoptixSonetPmConformance
1.3.6.1.2.1.10.3.20.20.20.1NodeoptixSonetPmGroups
1.3.6.1.2.1.10.3.20.20.20.1.1GroupoptixSonetPmObjectGroupcurrentEnter the description of the created OBJECT-GROUP.
1.3.6.1.2.1.10.3.20.20.20.2NodeoptixSonetPmCompliances
1.3.6.1.2.1.10.3.20.20.20.2.1ComplianceoptixSonetPmBasicCompliancecurrentEnter the description of the created MODULE-COMPLIANCE.