PAD-OPT-MIB
175 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC1155-SMI | Counter enterprises |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.449 | Nodecodex | |||
| 1.3.6.1.4.1.449.2 | NodecdxProductSpecific | |||
| 1.3.6.1.4.1.449.2.1 | Nodecdx6500 | |||
| 1.3.6.1.4.1.449.2.1.2 | Nodecdx6500Configuration | |||
| 1.3.6.1.4.1.449.2.1.2.1 | Nodecdx6500CfgProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.2.1.1 | Nodecdx6500PCTPortProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.2.1.1.1 | Tablecdx6500PPCTPadPortTable | not-accessible | mandatory | All of the configuration parameters relevant to the Pad Port table. |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1 | Rowcdx6500PPCTPadPortEntry | not-accessible | mandatory | A row of Pad Port configuration parameters. |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.1 | Columncdx6500padpCfgPortNum | read-only | mandatory | Specifies the number of the port that you are configuring. This number also serves as an entry number for the port you are about to configure. |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.2 | Columncdx6500padpCfgConnectionType | read-write | mandatory | Specify the control signal handshake and clocking required for a connection to be made to this port: simp - simple, no control signals required. dtr - dedicate… |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.3 | Columncdx6500padpCfgPortControl | read-write | mandatory | Specify any of the following port control options: NONE - no option specified. MB - raise Pin 22 when the port becomes disabled. |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.4 | Columncdx6500padpCfgPortSpeed | read-write | mandatory | This is the speed of the port in bits per second (baud rate). newvalSpeed110 : same as 'speed110', new enumeration added for RFC1155 compliance. |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.5 | Columncdx6500padpCfgAutoBaudSeq | read-write | mandatory | This is the type of sequence used for autospeed detection on an autospeed port. crOnly - autospeed on <CR> crDotCr - autospeed on <CR>.<CR> tymnet - autospeed … |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.6 | Columncdx6500padpCfgDataBits | read-write | mandatory | This is the number of data bits per character the PAD port expects when it transmits and receives data from the attached device. |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.7 | Columncdx6500padpCfgParity | read-write | mandatory | This is the parity the PAD port generates and expects when it transmits and receives data from the attached device. none - no parity space - Space Parity mark … |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.8 | Columncdx6500padpCfgStopBits | read-write | mandatory | This is the number of stop bits that the PAD port generates when it transmits data to the attached device. This parameter has no effect on data that is receive… |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.9 | Columncdx6500padpCfgProfileName | read-write | mandatory | This is the name of the PAD profile table to be used by this PAD port. |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.10 | Columncdx6500padpCfgCallControl | read-write | mandatory | This parameter allows call control to be used as follows: NONE - no option specified AUTO - automatic calling AUTC - automatic calling when carriage return rec… |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.11 | Columncdx6500padpCfgTermControl | read-write | mandatory | Specify options for the attached device: NONE - no option specified. PASS - require password entry to use this PAD facility. LIM - limit X.28 access to CALL an… |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.12 | Columncdx6500padpCfgPadPromptNum | read-write | mandatory | This parameter specifies which entry in the PAD Prompt Table is used as a PAD prompt. |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.13 | Columncdx6500padpCfgRemoteParamNum | read-write | mandatory | This specifies which entry in the Remote PAD Parameters Table is sent to a remote PAD to update its X.3 characteristics when it connects to this port: 0 - no r… |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.14 | Columncdx6500padpCfgAutoCallMnem | read-write | mandatory | This mnemonic name is used if this port is configured for auto-calling. |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.15 | Columncdx6500padpCfgAutoCallTimeout | read-write | mandatory | This is the time interval in seconds between call attempts when auto-calling. |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.16 | Columncdx6500padpCfgMaxAutoCall | read-write | mandatory | This parameter is used to specify the number of times that the PAD port will attempt to call, when auto-calling is enabled. A value of zero, will allow unlimit… |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.17 | Columncdx6500padpCfgSubAddress | read-write | mandatory | Calls addressed to this node and with this subaddress will be routed to this port. |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.18 | Columncdx6500padpCfgGroupSubaddress | read-only | mandatory | The group subaddress is shared by one or more ports. Calls addressed to this node and with this subaddress will be routed to a port within the group. |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.19 | Columncdx6500padpCfgCugMembership | read-write | mandatory | The port may be a member of up to 8 different Closed User Groups (CUGs). Each CUG membership must be a two digit number (except ( e.g. 12,34,56,09,02,03 ). 00-… |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.20 | Columncdx6500padpCfgBillingRecord | read-write | mandatory | This controls whether billing (accounting) records will be created for calls on this port. newvalOff : same functionality as 'off', new enumeration added for R… |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.21 | Columncdx6500padpCfgInviteToClr | read-write | mandatory | This specifies the handling of Invitation to Clear packet when received. none - Do nothing. clrwo - Clear Call without performing a EIA disconnect. clrwd - Cle… |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.22 | Columncdx6500padpCfgCallAcceptTime | read-write | mandatory | Specifies the time (in seconds) that the user has to make a successful call, after a call has been cleared, before being automatically disconnected. A maximum … |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.23 | Columncdx6500padpCfgProtectionLevel | read-write | mandatory | This specifies the level of data or connection protection which will be applied to calls to or from this port. The actual level for a call will be negotiated t… |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.24 | Columncdx6500padpCfgReconnectTimeout | read-write | mandatory | This specifies the number of seconds that DCP on the originating side will wait between reconnection attempts. |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.25 | Columncdx6500padpCfgReconnectTries | read-write | mandatory | This specifies the number of times that DCP on the originating side will attempt to reconnect before clearing the call. If 0 is entered, it will not attempt to… |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.26 | Columncdx6500padpCfgMaxRcvBufLength | read-write | mandatory | This specifies the number of characters received by the driver before forwarding the packet. This parameter is configurable only for PAD ports of CPU+ cards. 1… |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.27 | Columncdx6500padpCfgCommandLanguage | read-write | mandatory | This specifies the language for PAD commands. ccitt : X.28 CCITT. dpn : DPN ITI. nc : Not configured. |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.28 | Columncdx6500padpCfgNUIFacilityFormat | read-write | mandatory | This parameter specifies the format of the NUI facility field. odpn : Specifies the old DPN format. ndpn : Specifies the new DPN format. dpn1992 : 1992 NUI for… |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.29 | Columncdx6500padpCfgNUIVerifyTimer | read-write | mandatory | Specify the NUI verification timer in seconds. The call is cleared when the timer expires. |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.30 | Columncdx6500padpCfgMaxNUIViolations | read-write | mandatory | The maximum number of successive NUI verification failures that can be tolerated when making verification attempts through a pad port. |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.31 | Columncdx6500padpCfgActionTypeNUIV | read-write | mandatory | This specifies the course of action to be taken if the NUI violations exceed the configured threshold count. This parameter is effective only if the Port Contr… |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.32 | Columncdx6500padpCfgCalledDTEAddress | read-write | mandatory | Called DTE Address for packets with Call Mnemonic. |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.33 | Columncdx6500padpCfgCallingDTEIdent | read-write | mandatory | Calling DTE Identifier for packets with Call Mnemonic. |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.34 | Columncdx6500padpCfgCallingDTEPasswd | read-write | mandatory | Calling DTE Password for packets with Call Mnemonic. |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.35 | Columncdx6500padpCfgX28ResetService | read-write | mandatory | This is the name of the X.28 Reset Service Signals table to be used by this PAD port. |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.36 | Columncdx6500padpCfgX28ClearService | read-write | mandatory | This is the name of the X.28 Clear Service Signals table to be used by this PAD port. |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.37 | Columncdx6500padpCfgMAXMNEMFailures | read-write | mandatory | The maximum number of successive Mnemonic Call failures that can be tolerated when making a call to the remote using the mnemonic. This parameter is effective … |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.38 | Columncdx6500padpCfgActionTypeMNEMFail | read-write | mandatory | This specifies the course of action to be taken if the Mnemonic exceed the configured threshold count. This parameter is effective only if the Port Control par… |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.39 | Columncdx6500padpCfgActiveLineMessage | read-write | mandatory | The message to be printed when the line becomes active (DTR goes high). |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.40 | Columncdx6500padpCfgDelayActiveLine | read-write | mandatory | When the line becomes active (DTR goes high), Active line message is sent after configured time. This delay is in seconds. |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.41 | Columncdx6500padpCfgInterCharTimer | read-write | mandatory | The maximum time period allowed between received characters in a frame. Specified in 50ms increments (i.e. 5 means 250ms). |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.42 | Columncdx6500padpCfgElectricalInterfaceType | read-write | mandatory | Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 -… |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.43 | Columncdx6500padpCfgV24ElectricalInterfaceOption | read-write | mandatory | Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.44 | Columncdx6500padpCfgHighSpeedElectricalInterfaceOption | read-write | mandatory | Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable |
| 1.3.6.1.4.1.449.2.1.2.2 | Nodecdx6500CfgGeneralGroup | |||
| 1.3.6.1.4.1.449.2.1.2.2.4 | Tablecdx6500CfgPadPromptTable | not-accessible | mandatory | All of the configuration parameters relevant to the PAD Prompt table. |
| 1.3.6.1.4.1.449.2.1.2.2.4.1 | Rowcdx6500CfgPadPromptEntry | not-accessible | mandatory | A row of Pad Prompt table parameters |
| 1.3.6.1.4.1.449.2.1.2.2.4.1.1 | Columncdx6500padpromptEntryNum | read-only | mandatory | This is not a configuration parameter. Instead, it identifies the particular PAD Prompt Table entry being configured by the other parameter in the record. |
| 1.3.6.1.4.1.449.2.1.2.2.4.1.2 | Columncdx6500padpromptPromptText | read-only | mandatory | Enter PAD prompt as an ASCII character string, terminated by a carriage return. Use line feed (^j) to generate a new line. The prompt can have up to 1023 chara… |
| 1.3.6.1.4.1.449.2.1.2.2.8 | Tablecdx6500CfgPadProfileTable | not-accessible | mandatory | All of the configuration parameters relevant to the Pad Profile table. |
| 1.3.6.1.4.1.449.2.1.2.2.8.1 | Rowcdx6500CfgPadProfileEntry | not-accessible | mandatory | A row of Pad Profile configuration parameters |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.1 | Columncdx6500padprofProfileNum | read-only | mandatory | This is not a configuration parameter. Instead, it identifies the particular PAD Profile Table entry being configured by the other parameters in the record. |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.2 | Columncdx6500padprofProfileName | read-only | mandatory | Reference name for this PAD profile. Individual parameter prompt messages are prefixed with X.3 parameter number. Numbers greater than 100 indicate proprietary… |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.3 | Columncdx6500padprofPar1 | read-only | mandatory | #1, enables PAD recall to command mode during a call: 0 - PAD recall disabled 1 - PAD recall character = DLE = <^P> 32-126 - decimal value of character used fo… |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.4 | Columncdx6500padprofPar2 | read-only | mandatory | #2, controls echo: 0 - echo disabled 1 - echo enabled. |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.5 | Columncdx6500padprofPar3 | read-only | mandatory | #3, selects the ASCII characters used for data forwarding: 0 - no data forwarding characters 1 - A-Z, a-z, 0-9 2 - CR 4 - ESC, BEL,ENQ, ACK 8 - DEL, CAN, DC2 1… |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.6 | Columncdx6500padprofPar4 | read-only | mandatory | #4, selects forwarding idle timer delay: 0 - idle timer disabled 1 to 255 - value of idle timer in 1/20 seconds. |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.7 | Columncdx6500padprofPar5 | read-only | mandatory | #5, specifies whether the attached terminal is flow controlled (restrained from sending data) by the PAD port sending the XON, XOFF characters. Also called Dat… |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.8 | Columncdx6500padprofPar6 | read-only | mandatory | #6, controls PAD service signal messages to the attached device: 0 - no service signal is sent 1 - service signals, other than the prompt, are sent 4 - prompt … |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.9 | Columncdx6500padprofPar7 | read-only | mandatory | #7, selects the PAD mode of operation on receipt of a break signal from the attached terminal: 0 - do nothing 1 - send Interrupt packet 2 - send Reset packet 4… |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.10 | Columncdx6500padprofPar9 | read-only | mandatory | #9, controls padding after carriage return (CR): 0 - no padding after CR. 1 to 255 - number of padding characters inserted after CR. |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.11 | Columncdx6500padprofPar10 | read-only | mandatory | #10, controls line folding: 0 - no line folding. 1 to 255 - number of characters per line. |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.12 | Columncdx6500padprofPar12 | read-only | mandatory | #12, specifies whether the PAD port is flow controlled (restrained from sending data) by the attached terminal sending the XON, XOFF characters. Also called Da… |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.13 | Columncdx6500padprofPar13 | read-only | mandatory | #13, controls line feed insertion after carriage return (CR) in data transfer state: 0 - no line feed insertion 1 - after CR in data sent to attached device 2 … |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.14 | Columncdx6500padprofPar14 | read-only | mandatory | #14, controls padding after line feed in the data transfer state: 0 - no padding after line feed 1 to 255 - number of padding characters inserted after line fe… |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.15 | Columncdx6500padprofPar15 | read-only | mandatory | #15, controls local editing in data transfer state: 0 - no editing 1 - allow editing (idle timer data forwarding must be disabled, parameter #4 = 0) Editing is… |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.16 | Columncdx6500padprofPar16 | read-only | mandatory | #16, decimal value of ASCII character used to delete a character if editing is enabled (parameter #15 = 1). |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.17 | Columncdx6500padprofPar17 | read-only | mandatory | #17, decimal value of ASCII character used to delete a line if editing is enabled (parameter #15 = 1). |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.18 | Columncdx6500padprofPar18 | read-only | mandatory | #18, decimal value of ASCII character used to display a line if editing is enabled (parameter #15 = 1). |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.19 | Columncdx6500padprofPar19 | read-only | mandatory | #19, specifies the type of character delete service signal sent by PAD: 0 - no service signal 1 - printing terminals (PAD sends \\ for each delete character re… |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.20 | Columncdx6500padprofPar20 | read-only | mandatory | #20, specifies the echo mask: 0 - no echo mask (all characters echoed) 1 - no echo of CR 2 - no echo of LF 4 - no echo of VT, HT, or FF 8 - no echo of BEL or B… |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.21 | Columncdx6500padprofPar21 | read-only | mandatory | #21, controls the parity treatment of characters received and transmitted to the attached device. 0 - No parity checking or generation 1 - Parity checked on re… |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.22 | Columncdx6500padprofPar22 | read-only | mandatory | #22, controls page wait: 0 - page wait disabled. 1 to 255 - number of line feed characters sent by the PAD for the page wait function. |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.23 | Columncdx6500padprofPar100 | read-only | mandatory | #100, specifies the ASCII character used to simulate break for attached terminals that do not have a break key: 0 - no break character defined 1 to 127 - decim… |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.24 | Columncdx6500padprofPar101 | read-only | mandatory | #101, specifies the ASCII character used to toggle echo substitution of entered data. This function available only if parameter #2 = 1: 0 - no echo substitutio… |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.25 | Columncdx6500padprofPar102 | read-only | mandatory | #102, specifies the ASCII character used to echo all characters entered by the attached device when echo substitution is toggled on: 0 - no echo when echo subs… |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.26 | Columncdx6500padprofPar103 | read-only | mandatory | #103, specifies the ASCII character used for the XON function: 0 to 255 - decimal value of the XON character |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.27 | Columncdx6500padprofPar104 | read-only | mandatory | #104, specifies the ASCII character used for the XOFF function: 0 to 255 - decimal value of the XOFF character. |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.28 | Columncdx6500padprofPar105 | read-only | mandatory | #105, specifies whether both the PAD and the attached terminal are flow controlled (restrained from sending data) by the use of V.24 control signals, rather th… |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.29 | Columncdx6500padprofPar106 | read-only | mandatory | #106, specifies parity of data sent to the network by the PAD: 0 - transparent - pass data as received 1 - space 2 - mark 3 - even 4 - odd |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.30 | Columncdx6500padprofPar107 | read-only | mandatory | #107, is the elapsed time of no user data input after which a call on the port will be cleared: 0 - timer disabled 1 to 255 - timer value in minutes. |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.31 | Columncdx6500padprofPar108 | read-only | mandatory | #108, specifies the ASCII character used to disconnect a call: 0 - no character disconnects the call. 1 to 127 - decimal value of call disconnect character. |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.32 | Columncdx6500padprofPar109 | read-only | mandatory | #109, specifies the number of padding characters inserted in the data sent to the attached device after a form feed: 0 - no padding characters inserted. 1 to 2… |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.33 | Columncdx6500padprofPar110 | read-only | mandatory | #110, Selects the data forwarding delay after ESC is detected 0 - timer disabled. 1 to 255 - timer value in 1/20 second. |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.34 | Columncdx6500padprofPar111 | read-only | mandatory | #111, Controls how the pad handles the echo of data when echo, parameter 2, is on. 0 - No Priority. Data is output and characters are echoed as they arrive. 1 … |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.35 | Columncdx6500padprofPar112 | read-only | mandatory | #112, Setting this parameter causes the PAD port to dynamically forward data packets, as bandwidth becomes available on the network link. Settings for X.3 para… |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.36 | Columncdx6500padprofPar113 | read-only | mandatory | #113, Controls Hewlett-Packard flow control. 0 - No HP flow control. 1 - HP host enq/ack control. 2 - HP terminal enq/ack control. 3 - HP host xon/xoff control… |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.37 | Columncdx6500padprofPar114 | read-only | mandatory | #114, Selects PAD operational mode: 0 - Normal PAD. 1 - Transparent Polled Async Host PAD. 2 - Transparent Polled Async Remote PAD. |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.38 | Columncdx6500padprofPar115 | read-only | mandatory | #115, Selects Data Forwarding Criteria for Polled Async PADs: 0 - Normal. 1 - Short Timer. 2 - RTS Signal Drop. |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.39 | Columncdx6500padprofPar116 | read-only | mandatory | #116, Selects forwarding Short Timer duration for Polled Async PADs: 0 - Short Timer disabled. 1 to 255 - Duration of Short Timer in milliseconds. |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.40 | Columncdx6500padprofPar117 | read-only | mandatory | #117, Selects EIA Signalling Action for Polled Async PADs: 0 - None. 1 - Raise DCD before transmission and drop DCD after transmission. |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.41 | Columncdx6500padprofPar118 | read-only | mandatory | #118, Setting this parameter causes a Polled Async PAD to buffer complete async messages from the network before transmitting them to the attached device. 0 - … |
| 1.3.6.1.4.1.449.2.1.2.2.8.1.42 | Columncdx6500padprofPar119 | read-only | mandatory | #119, This parameter specifies the amount of time that DCD is held high before data transmission to the attached device begins. This parameter is used when EIA… |
| 1.3.6.1.4.1.449.2.1.2.2.9 | Tablecdx6500CfgRemotePadTable | not-accessible | mandatory | All of the configuration parameters relevant to the Remote Pad Paramter table. |
| 1.3.6.1.4.1.449.2.1.2.2.9.1 | Rowcdx6500CfgRemotePadEntry | not-accessible | mandatory | A row of Remote Pad configuration parameters |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.1 | Columncdx6500remotepadEntryNum | read-only | mandatory | This is not a configuration parameter. Instead, it identifies the particular PAD Parameter Table entry being configured by the other parameters in the record. … |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.2 | Columncdx6500remotepadParamNum1 | read-only | mandatory | Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall… |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.3 | Columncdx6500remotepadParamVal1 | read-only | mandatory | Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter. |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.4 | Columncdx6500remotepadParamNum2 | read-only | mandatory | Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall… |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.5 | Columncdx6500remotepadParamVal2 | read-only | mandatory | Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter. |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.6 | Columncdx6500remotepadParamNum3 | read-only | mandatory | Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall… |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.7 | Columncdx6500remotepadParamVal3 | read-only | mandatory | Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter. |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.8 | Columncdx6500remotepadParamNum4 | read-only | mandatory | Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall… |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.9 | Columncdx6500remotepadParamVal4 | read-only | mandatory | Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter. |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.10 | Columncdx6500remotepadParamNum5 | read-only | mandatory | Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall… |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.11 | Columncdx6500remotepadParamVal5 | read-only | mandatory | Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter. |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.12 | Columncdx6500remotepadParamNum6 | read-only | mandatory | Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall… |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.13 | Columncdx6500remotepadParamVal6 | read-only | mandatory | Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter. |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.14 | Columncdx6500remotepadParamNum7 | read-only | mandatory | Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall… |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.15 | Columncdx6500remotepadParamVal7 | read-only | mandatory | Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter. |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.16 | Columncdx6500remotepadParamNum8 | read-only | mandatory | Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall… |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.17 | Columncdx6500remotepadParamVal8 | read-only | mandatory | Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter. |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.18 | Columncdx6500remotepadParamNum9 | read-only | mandatory | Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall… |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.19 | Columncdx6500remotepadParamVal9 | read-only | mandatory | Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter. |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.20 | Columncdx6500remotepadParamNum10 | read-only | mandatory | Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall… |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.21 | Columncdx6500remotepadParamVal10 | read-only | mandatory | Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter. |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.22 | Columncdx6500remotepadParamNum11 | read-only | mandatory | Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall… |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.23 | Columncdx6500remotepadParamVal11 | read-only | mandatory | Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter. |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.24 | Columncdx6500remotepadParamNum12 | read-only | mandatory | Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall… |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.25 | Columncdx6500remotepadParamVal12 | read-only | mandatory | Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter. |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.26 | Columncdx6500remotepadParamNum13 | read-only | mandatory | Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall… |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.27 | Columncdx6500remotepadParamVal13 | read-only | mandatory | Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter. |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.28 | Columncdx6500remotepadParamNum14 | read-only | mandatory | Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall… |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.29 | Columncdx6500remotepadParamVal14 | read-only | mandatory | Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter. |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.30 | Columncdx6500remotepadParamNum15 | read-only | mandatory | Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall… |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.31 | Columncdx6500remotepadParamVal15 | read-only | mandatory | Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter. |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.32 | Columncdx6500remotepadParamNum16 | read-only | mandatory | Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall… |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.33 | Columncdx6500remotepadParamVal16 | read-only | mandatory | Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter. |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.34 | Columncdx6500remotepadParamNum17 | read-only | mandatory | Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall… |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.35 | Columncdx6500remotepadParamVal17 | read-only | mandatory | Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter. |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.36 | Columncdx6500remotepadParamNum18 | read-only | mandatory | Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall… |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.37 | Columncdx6500remotepadParamVal18 | read-only | mandatory | Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter. |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.38 | Columncdx6500remotepadParamNum19 | read-only | mandatory | Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall… |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.39 | Columncdx6500remotepadParamVal19 | read-only | mandatory | Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter. |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.40 | Columncdx6500remotepadParamNum20 | read-only | mandatory | Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall… |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.41 | Columncdx6500remotepadParamVal20 | read-only | mandatory | Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter. |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.42 | Columncdx6500remotepadParamNum21 | read-only | mandatory | Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall… |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.43 | Columncdx6500remotepadParamVal21 | read-only | mandatory | Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter. |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.44 | Columncdx6500remotepadParamNum22 | read-only | mandatory | Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall… |
| 1.3.6.1.4.1.449.2.1.2.2.9.1.45 | Columncdx6500remotepadParamVal22 | read-only | mandatory | Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter. |
| 1.3.6.1.4.1.449.2.1.3 | Nodecdx6500Statistics | |||
| 1.3.6.1.4.1.449.2.1.3.1 | Nodecdx6500StatProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.3.1.1 | Nodecdx6500PSTPortProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.3.1.1.1 | Tablecdx6500PPSTPadPortTable | not-accessible | mandatory | All of the statistics parameters relevant to the Pad Port table. |
| 1.3.6.1.4.1.449.2.1.3.1.1.1.1 | Rowcdx6500PPSTPadPortEntry | not-accessible | mandatory | A row of Pad Port statistics parameters. |
| 1.3.6.1.4.1.449.2.1.3.1.1.1.1.1 | Columncdx6500padpStatPortNum | read-only | mandatory | Number of the port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.1.1.2 | Columncdx6500padpStatPortStatus | read-only | mandatory | Status of the port: up - port is up and running. busyout - port has been busied out. disabled - port has been disabled. newvalDisabled : same functionality 'di… |
| 1.3.6.1.4.1.449.2.1.3.1.1.1.1.3 | Columncdx6500padpStatUtilizationIn | read-only | mandatory | Percentage of port bandwidth in use. |
| 1.3.6.1.4.1.449.2.1.3.1.1.1.1.4 | Columncdx6500padpStatUtilizationOut | read-only | mandatory | Percentage of port bandwidth in use. |
| 1.3.6.1.4.1.449.2.1.3.1.1.1.1.5 | Columncdx6500padpStatPortSpeed | read-only | mandatory | The configured port speed. |
| 1.3.6.1.4.1.449.2.1.3.1.1.1.1.6 | Columncdx6500padpStatCharInTotal | read-only | mandatory | Summary of the characters being received over the port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.1.1.7 | Columncdx6500padpStatCharOutTotal | read-only | mandatory | Summary of the characters being sent over the port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.1.1.8 | Columncdx6500padpStatCharsInPerSec | read-only | mandatory | Summary of the characters being received over the port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.1.1.9 | Columncdx6500padpStatCharsOutPerSec | read-only | mandatory | Summary of the characters being sent over the port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.1.1.10 | Columncdx6500padpStatPktInTotal | read-only | mandatory | Summary of the packets being sent over the port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.1.1.11 | Columncdx6500padpStatPktOutTotal | read-only | mandatory | Summary of the packets being sent over the port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.1.1.12 | Columncdx6500padpStatPktsInPerSec | read-only | mandatory | Summary of the packets being sent over the port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.1.1.13 | Columncdx6500padpStatPktsOutPerSec | read-only | mandatory | Summary of the packets being sent over the port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.1.1.14 | Columncdx6500padpStatPktsQueued | read-only | mandatory | Number of packets queued for output. |
| 1.3.6.1.4.1.449.2.1.3.1.1.1.1.15 | Columncdx6500padpStatOverrunErrors | read-only | mandatory | Number of Overrun errors since the last reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.1.1.16 | Columncdx6500padpStatParityErrors | read-only | mandatory | Number of Parity errors since the last reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.1.1.17 | Columncdx6500padpStatFramingErrors | read-only | mandatory | Number of Framing errors since the last reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.1.1.18 | Columncdx6500padpStatCurrentStatus | read-only | mandatory | Status of the call on the specific port (Disconnect, Calling, Called, Clearing, Connected, Local Copy) |
| 1.3.6.1.4.1.449.2.1.3.1.1.1.1.19 | Columncdx6500padpStatPortState | read-only | mandatory | Current port state: x28 : The port is in Command mode. pad : The port is in Data mode. account : The port is waiting for the account name. password : The port … |
| 1.3.6.1.4.1.449.2.1.4 | Nodecdx6500Controls |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| Counter16 | INTEGER (0..65535) | ||
| DisplayString | OCTET STRING |