MIB Viewer

PBC-GENERIC-MIB

45 objects
This module defines management objects which are common to all PBC chassis/system products.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.5987.1.1.1IdentitypbcGenericSystemMibThis module defines management objects which are common to all PBC chassis/system products.
1.3.6.1.4.1.5987.2.1NodepbcGeneric
1.3.6.1.4.1.5987.2.1.1NodepbcChassis
1.3.6.1.4.1.5987.2.1.1.1ScalarpbcChassisEntityIndexread-onlycurrententPhysicalIndex of the chassis' entry in the Entity MIB's (RFC2737) entPhysicalTable or '0', if none.
1.3.6.1.4.1.5987.2.1.1.2ScalarpbcChassisOperStatusread-onlycurrentChassis' current operational status.
1.3.6.1.4.1.5987.2.1.1.3ScalarpbcChassisSlotsread-onlycurrentNumber of slots in this chassis, or '0' if neither applicable nor determinable.
1.3.6.1.4.1.5987.2.1.1.4ScalarpbcContactInforead-onlycurrentPacific Broadband contact information.
1.3.6.1.4.1.5987.2.1.1.5ScalarpbcHostNameread-writecurrentName of this system.
1.3.6.1.4.1.5987.2.1.1.6ScalarpbcDomainNameread-writecurrentDomain name for this host.
1.3.6.1.4.1.5987.2.1.1.7ScalarpbcDateTimeOfLastChangeread-onlycurrentDate and time of last change to either the configuration or the software.
1.3.6.1.4.1.5987.2.1.1.8ScalarpbcCardIfIndexTableNumEntriesread-onlycurrentNumber of entries currently in the pbcCardIfIndexTable. This should be the same number as there are entries in the ifTable.
1.3.6.1.4.1.5987.2.1.1.9TablepbcCardIfIndexTablenot-accessiblecurrentFor each ifIndex currently exposed by the system, this table will provide an association to the physical and logical objects which are related to it.
1.3.6.1.4.1.5987.2.1.1.9.1RowpbcCardIfIndexEntrynot-accessiblecurrentOne ifIndex mapping entry.
1.3.6.1.4.1.5987.2.1.1.9.1.1ColumnpbcCardIfCardIndexread-onlycurrentIndex of the card in the Chassis pbcCardTable which contains this interface or '0' if not applicable.
1.3.6.1.4.1.5987.2.1.1.9.1.2ColumnpbcCardIfPortNumberread-onlycurrentChassis port number, unique per port on a given card for the same interface type. If pbcCardIfPortNumber is not applicable to the card, then the object instanc…
1.3.6.1.4.1.5987.2.1.1.9.1.3ColumnpbcCardIfPortTyperead-onlycurrentThe type of port associated with this ifIndex: 0 = Not Applicable 1 = Downstream 2 = Upstream 3 = Fast Ethernet 4 = Gigabit Ethernet 5 = 10 Gigabit Ethernet 6 …
1.3.6.1.4.1.5987.2.1.1.9.1.4ColumnpbcCardIfSlotNumberread-onlycurrentChassis slot number, or '0' if neither applicable nor determinable.
1.3.6.1.4.1.5987.2.1.1.9.1.5ColumnpbcCardIfPortIndexread-onlycurrentThe system unique port index number for the physical port associated with this ifIndex.
1.3.6.1.4.1.5987.2.1.1.10ScalarpbcCardTableNumEntriesread-onlycurrentNumber of entries currently in the pbcCardTable.
1.3.6.1.4.1.5987.2.1.1.11TablepbcCardTablenot-accessiblecurrentChassis card table.
1.3.6.1.4.1.5987.2.1.1.11.1RowpbcCardEntrynot-accessiblecurrentInstalled card types are enumerated here. These entries should not be removed when a card is ejected from the system. The pbcCardOperStatus of the ejected card…
1.3.6.1.4.1.5987.2.1.1.11.1.1ColumnpbcCardSlotNumberread-onlycurrentSlot number relative to the containing card or chassis, or '0' if neither applicable nor determinable.
1.3.6.1.4.1.5987.2.1.1.11.1.2ColumnpbcCardEntityIndexread-onlycurrententPhysicalIndex of this card's entry in the Entity MIB's (RFC2737) entPhysicalTable or '0', if none.
1.3.6.1.4.1.5987.2.1.1.11.1.3ColumnpbcCardAdminStatusread-writecurrentThe desired state of the card. When a card/module initializes, its initial pbcCardAdminStatus is down(2). As a result of either explicit management action or p…
1.3.6.1.4.1.5987.2.1.1.11.1.4ColumnpbcCardOperStatusread-onlycurrentThe operational status of the card. The pbcCardOperStatus is operational(2) when a card is recognized by the device and is enabled for operation. pbcCardOperSt…
1.3.6.1.4.1.5987.2.1.1.11.1.5ColumnpbcCardUpTimeread-onlycurrentThe value of sysUpTime for this management entity, when this card was last (re-)initialized.
1.3.6.1.4.1.5987.2.1.1.11.1.6ColumnpbcCardnvRAMSizeread-onlycurrentAmount of non-volatile RAM in bytes.
1.3.6.1.4.1.5987.2.1.1.11.1.7ColumnpbcCardNumPortsread-onlycurrentNumber of ports on this card, or '0' if no ports or not applicable or determinable.
1.3.6.1.4.1.5987.2.1.1.11.1.8ColumnpbcCardTyperead-onlycurrentThe card type of the card. Here are the various types of cards supported: ccm -Chassis Control Module dm - DOCSIS Module nic - Network Interface Module rim - R…
1.3.6.1.4.1.5987.2.1.1.11.1.9ColumnpbcCardPositionread-onlycurrentThe position of the card relative to the midplane. The pbcCardTable may contain one or two entry per slot. If there are two entries present per slot, then the …
1.3.6.1.4.1.5987.2.1.1.12TablepbcCardPortTablenot-accessiblecurrentDescribes the ports on a particular card and their current status.
1.3.6.1.4.1.5987.2.1.1.12.1RowpbcCardPortEntrynot-accessiblecurrentPort characteristics comprising an entry in the table. These entries should not be removed when a card is ejected from the system. The pbcCardPortStatus of the…
1.3.6.1.4.1.5987.2.1.1.12.1.1ColumnpbcCardPortStatusread-onlycurrentThe current operational status of this port. pbcCardPortStatus is active(2) when a port is enabled for operation. pbcCardPortStatus is disabled(3) if the port …
1.3.6.1.4.1.5987.2.1.1.12.1.2ColumnpbcCardPortEntityIndexread-onlycurrententPhysicalIndex of this port's entry in the Entity MIB's (RFC2737) entPhysicalTable or '0', if none.
1.3.6.1.4.1.5987.2.1.1.12.1.3ColumnpbcCardPortAliasread-writecurrentAlias name for the port as specified by a network manager. On the first instantiation of the interface, the value of the pbcCardPortAlias is zero-length string…
1.3.6.1.4.1.5987.2.1.1.13TablepbcPortIfTablenot-accessiblecurrentLists the interfaces (ifIndex values) associated with a specific port.
1.3.6.1.4.1.5987.2.1.1.13.1RowpbcPortIfEntrynot-accessiblecurrentAn entry in the pbcPortIfEntry table. For each port number within the system, assigned by the chassis CCM, there is one entry for each IfIndex associated with …
1.3.6.1.4.1.5987.2.1.1.13.1.1ColumnpbcPortIfIndexread-onlycurrentifIndex associated with this port or '-1', if none.
1.3.6.1.4.1.5987.2.1.2NodepbcGenericConformance
1.3.6.1.4.1.5987.2.1.2.1NodepbcGenericGroups
1.3.6.1.4.1.5987.2.1.2.1.1GrouppbcChassisGroupcurrentObjects associated with generic PBC chassis management.
1.3.6.1.4.1.5987.2.1.2.2NodepbcGenericCompliance
1.3.6.1.4.1.5987.2.1.2.2.1CompliancepbcGenericBasicCompliancecurrentGroup support required for basic level compliance.
Type Definitions
NameSyntaxStatusDescription
ChgHistoryDataPathINTEGER { erase(1), cmdSource(2), startup(3), operational(4), tftp(5), local(6) }currentConfiguration change data's source or destination.
PortTypeINTEGER { notApplicable(0), cableDS(1), cableUS(2), fastEthernet(3), gigabitEthernet(4), tenGigabitEthernet(5), rs232(6), cableUsLogical(7) }currentThe type of data port: 0 = Not Applicable 1 = cableDS (cable downstream) 2 = cableUS (cable upstream physical) 3 = Fast Ethernet 4 = Gigabit Ethernet 5 = 10 Gigabit Ethernet 6 = RS-232 7 = cableUsLogical (cable upstream…