MIB Viewer

PEA-EQUIPMENT

116 objects
The public ethernet access software supports a number of standard and proprietary MIBs. This MIB module defines objects for reading/writing common equipment information.
Imported Objects
IF-MIBifIndex InterfaceIndex
PEA-SMIpea
PEM-STANDARD733 header for the traps managedObjectClass eventTime eventTypePem managedObjectInstance perceivedSeverity probableCause sequenceNumber
POWER-ETHERNET-MIB-- pethMainPseConsumptionPower -- pethPsePortDetectionStatus --
RMON-MIB-- alarmFallingThreshold -- -- alarmIndex -- alarmRisingThreshold -- alarmSampleType -- alarmValue -- alarmVariable
SNMPv2-CONFNOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIInteger32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCDisplayString MacAddress TEXTUAL-CONVENTION TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.193.72.600.1IdentitypeaEquipmentThe public ethernet access software supports a number of standard and proprietary MIBs. This MIB module defines objects for reading/writing common equipment in…
1.3.6.1.4.1.193.72.600.1.1NodecommonObjects
1.3.6.1.4.1.193.72.600.1.1.1Nodeversions
1.3.6.1.4.1.193.72.600.1.1.1.1ScalarsysIdread-onlycurrentThis value includes the full name and version identification of the node software.
1.3.6.1.4.1.193.72.600.1.1.1.2ScalarbootSwIdread-onlycurrentThis value includes the full name and version identification of the BOOT software.
1.3.6.1.4.1.193.72.600.1.1.1.3ScalarcfgVerread-writecurrentThe CfgVer will initially be zero, but is set to the version number defined in the configuration file received from the tftp server at system start-up. The man…
1.3.6.1.4.1.193.72.600.1.1.1.4ScalaractiveSwInforead-onlycurrentThis value represents the software version of the active software part of the node.
1.3.6.1.4.1.193.72.600.1.1.1.5ScalarpassiveSwInforead-onlycurrentThis value represents the software version of the passive software part of the node.
1.3.6.1.4.1.193.72.600.1.1.2NodemainProcessor
1.3.6.1.4.1.193.72.600.1.1.2.1ScalarprocessorLoadread-onlycurrentThe percentage of time that the main processor was not idle. Average over 10 seconds. (almost like hrProcessorLoad in RFC1514).
1.3.6.1.4.1.193.72.600.1.1.2.2ScalarmemFreeread-onlycurrentThe amount of free memory on main processor in percent.
1.3.6.1.4.1.193.72.600.1.1.2.3ScalarmemFreeBytesread-onlycurrentThe amount of free memory on main processor in bytes.
1.3.6.1.4.1.193.72.600.1.1.2.4ScalarmemBuffersUsedread-onlycurrentThe total number of memory buffers currently used (Ethernet, ATM & local IP-stack).
1.3.6.1.4.1.193.72.600.1.1.3Nodetemperature
1.3.6.1.4.1.193.72.600.1.1.3.1ScalartempControlStateread-onlycurrentThe state of the temperature control can be: 0 - Low 1 - Normal 2 - High 3 - TooHigh
1.3.6.1.4.1.193.72.600.1.1.3.2ScalartempValueread-onlycurrentThe temperature value in the node in deg. Celsius.
1.3.6.1.4.1.193.72.600.1.1.4NodefansStatus
1.3.6.1.4.1.193.72.600.1.1.4.1ScalargreenFanStatusread-onlydeprecatedThe status of the fan which is placed closest to the green LED. For ESN310/ECN320/ECN330, green fan is the fan placed near the front. Made deprecated. Use the …
1.3.6.1.4.1.193.72.600.1.1.4.2ScalarredFanStatusread-onlydeprecatedThe status of the fan which is placed closest to the red LED. For ESN310/ECN320/ECN330, red fan is the fan placed near the rear. Made deprecated. Use the redFa…
1.3.6.1.4.1.193.72.600.1.1.4.3ScalargreenFanSpeedread-onlycurrentThe speed of the fan, which is placed closest to the green LED, measured in rpm (revolutions per minute). For ESN310/ECN320/ECN330, green fan is the fan placed…
1.3.6.1.4.1.193.72.600.1.1.4.4ScalarredFanSpeedread-onlycurrentThe speed of the fan, which is placed closest to the red LED, measured in rpm (revolutions per minute). For ESN310/ECN320/ECN330, red fan is the fan placed nea…
1.3.6.1.4.1.193.72.600.1.1.4.5ScalargreenFanPerfStatusread-onlycurrentThe performance status of the fan which is placed closest to the green LED. For ESN310/ECN320/ECN330, green fan is the fan placed near the front.
1.3.6.1.4.1.193.72.600.1.1.4.6ScalarredFanPerfStatusread-onlycurrentThe performance status of the fan which is placed closest to the red LED. For ESN310/ECN320/ECN330, red fan is the fan placed near the rear.
1.3.6.1.4.1.193.72.600.1.1.5NodealarmFilter
1.3.6.1.4.1.193.72.600.1.1.5.1ScalarcomAlarmFilterread-writecurrentThis alarm filter will filter out all communication alarms with lower severity than the selected. For example: Selecting minor (1) would filter out all alarms …
1.3.6.1.4.1.193.72.600.1.1.5.2ScalarenvAlarmFilterread-writecurrentThis alarm filter will filter out all environment alarms with lower severity than the selected. For example: Selecting minor (1) would filter out all alarms wi…
1.3.6.1.4.1.193.72.600.1.1.5.3ScalarequipAlarmFilterread-writecurrentThis alarm filter will filter out all equipment alarms with lower severity than the selected. For example: Selecting minor (1) would filter out all alarms with…
1.3.6.1.4.1.193.72.600.1.1.5.4ScalarprocessAlarmFilterread-writecurrentThis alarm filter will filter out all processing alarms with lower severity than the selected. For example: Selecting minor (1) would filter out all alarms wit…
1.3.6.1.4.1.193.72.600.1.1.5.5ScalarqosAlarmFilterread-writecurrentThis alarm filter will filter out all quality alarms with lower severity than the selected. For example: Selecting minor (1) would filter out all alarms with w…
1.3.6.1.4.1.193.72.600.1.1.5.6ScalaralarmFilterThresread-writeobsoleteThe threshold value indicates how many alarms that can be filtered by the node in the time interval indicated by the alarmFilterInterval parameter before an al…
1.3.6.1.4.1.193.72.600.1.1.5.7ScalaralarmFilterIntervalread-writeobsoleteThe value of this parameter indicates the time interval in which the node can filter a number of alarms indicated by the alarmFilterThres parameter before an a…
1.3.6.1.4.1.193.72.600.1.1.6NodeconfigurationData
1.3.6.1.4.1.193.72.600.1.1.6.1ScalarlocalMacAddrread-onlycurrentUnique MAC address of the node.
1.3.6.1.4.1.193.72.600.1.1.6.2ScalarphyModeread-writecurrentEthernet PHY Mode setting. The Phy Mode is coded as a bitfield: * Bit 0: Auto-negotiation. If set, auto-negotiation is OFF else ON. * Bit 2: Full Duplex contro…
1.3.6.1.4.1.193.72.600.1.1.6.3ScalarwatchDogEnableread-onlycurrentEnabling of the HW Watchdog. If 0 (zero), the watchdog is OFF, else the watchdog is ON.
1.3.6.1.4.1.193.72.600.1.1.6.5ScalarvlanIdread-writecurrentThe VLAN ID setting for the management VLAN.
1.3.6.1.4.1.193.72.600.1.1.6.6ScalarvlanPrioread-writecurrentSpecifies the IEEE 802.1Q priority used for the management VLAN.
1.3.6.1.4.1.193.72.600.1.1.6.7ScalarvlanTaggingread-writecurrentIf 0, VLAN tagging is off, meaning that VLAN is not used. If 1, VLAN tagging is used, with the given ID and Prio.
1.3.6.1.4.1.193.72.600.1.1.6.8ScalarbootStringread-onlycurrentText commands for the bootloader.
1.3.6.1.4.1.193.72.600.1.1.7NodeupgradeSW
1.3.6.1.4.1.193.72.600.1.1.7.1ScalarswFileNameread-writecurrentThe filename to upload to the node. The path to this file is in the root directory that is specified in the FTP server
1.3.6.1.4.1.193.72.600.1.1.7.2ScalaruploadSWread-writecurrentUpload new application software to device. The file which is loaded is indicated by the swFileName parameter. 1 - upload SW to the device and restart afterward…
1.3.6.1.4.1.193.72.600.1.1.7.3ScalarbootSwFileNameread-writecurrentThe filename of a boot sw image located on the domain file server. This file name is used by the uploadBootSw.
1.3.6.1.4.1.193.72.600.1.1.7.4ScalaruploadBootSwread-writecurrentUpload new boot software to this device. The boot sw image must be named by the bootSwFileName parameter and located on the domain file server, which is the ne…
1.3.6.1.4.1.193.72.600.1.1.8ScalarhideInternalInterfacesread-writecurrentThe management system can chose to hide all interfaces (RFC1233/RFC2233) that are irrelevant in the PEM network view (HP OpenView issue). If 0, Don't hide any …
1.3.6.1.4.1.193.72.600.1.1.9Scalarrestartread-writecurrentWhen set to 'restart' the node restarts, which includes loading the SW image and configuration data from the server. In this way a new SW version can be loaded…
1.3.6.1.4.1.193.72.600.1.1.10ScalarledsAltBlinkread-writecurrentWhen the ledsAltBlink is set to ON(1) the LEDs will start to blink alternatively.
1.3.6.1.4.1.193.72.600.1.1.11ScalarstartCfgVerificationread-writecurrentWhen startCfgVerification is set to verify(1) the node makes a DHCP renew and retrieves the configuration file from the address of the server just received fro…
1.3.6.1.4.1.193.72.600.1.1.12ScalarsaveCfgToNvmread-writecurrentWhen saveCfgToNvm is set to start(1) the device saves the configuration data parameters to NVM. Using GET command the current (inProgress) or last known state …
1.3.6.1.4.1.193.72.600.1.1.13ScalarcfgVerificationIntervalread-writecurrentThis is the time in minutes between configuration file verification. If the value is zero the configuration verification is disabled.
1.3.6.1.4.1.193.72.600.1.1.14ScalarnotifyTyperead-writecurrentSet the type of the notify sent by the node: 1. Trap 2. Inform
1.3.6.1.4.1.193.72.600.1.1.15NodeidentificationData
1.3.6.1.4.1.193.72.600.1.1.15.1NodedeviceIdData
1.3.6.1.4.1.193.72.600.1.1.15.1.1ScalarproductNumberread-onlycurrentIndex number that identifies the node.
1.3.6.1.4.1.193.72.600.1.1.15.1.2ScalarrevisionStateread-onlycurrentRevision State or 'R-state' declaring minor versions. For example: different types of components or new boot SW.
1.3.6.1.4.1.193.72.600.1.1.15.1.3ScalarfunctionDesignationread-onlycurrentNumber with reference to the handling and use of the product.
1.3.6.1.4.1.193.72.600.1.1.15.1.4ScalardateOfProductionread-onlycurrentManufacturing date, describing when the unit has been manufactured, in terms of a year, month and a day, as described below: Year code(0000 ..9999) - 2 bytes (…
1.3.6.1.4.1.193.72.600.1.1.15.1.5ScalardateOfRepairread-onlycurrentRepair date, declaring the year, month and day of the latest repair. The format is described below: Year code(0000 ..9999) - 2 bytes (LSB,MSB) Month (1..12)- 1…
1.3.6.1.4.1.193.72.600.1.1.15.1.6ScalarproductionSerialNumberread-onlycurrentUnique serial number, describing the product in terms of a manufacturing site code and a sequence number.
1.3.6.1.4.1.193.72.600.1.1.15.1.7ScalarlayoutVersionCoderead-onlycurrentThe data layout version that allows the possibility to interpret stored data differently.
1.3.6.1.4.1.193.72.600.1.1.15.1.8ScalaridCheckSumread-onlycurrentCRC32 Checksum of identification data structure of the node.
1.3.6.1.4.1.193.72.600.1.1.15.2NodemicroProcessorIdData
1.3.6.1.4.1.193.72.600.1.1.15.2.1ScalarproductNumberMicroProcessorread-onlycurrentIndex number that identifies the MicroProcessor board.
1.3.6.1.4.1.193.72.600.1.1.15.2.2ScalarrevisionStateMicroProcessorread-onlycurrentRevision State or 'R-state' declaring minor versions. For example: different types of components or new boot SW.
1.3.6.1.4.1.193.72.600.1.1.15.2.3ScalarfunctionDesignationMicroProcessorread-onlycurrentNumber with reference to the handling and use of the product.
1.3.6.1.4.1.193.72.600.1.1.15.2.4ScalardateOfProductionMicroProcessorread-onlycurrentManufacturing date, describing when the unit has been manufactured, in terms of a year, month and a day, as described below: Year code(0000 ..9999) - 2 bytes (…
1.3.6.1.4.1.193.72.600.1.1.15.2.5ScalardateOfRepairMicroProcessorread-onlycurrentRepair date, declaring the year, month and day of the latest repair. The format is described below: Year code(0000 ..9999) - 2 bytes (LSB,MSB) Month (1..12)- 1…
1.3.6.1.4.1.193.72.600.1.1.15.2.6ScalarproductionSerialNumberMicroProcessorread-onlycurrentUnique serial number, describing the product in terms of a manufacturing site code and a sequence number.
1.3.6.1.4.1.193.72.600.1.1.15.2.7ScalarlayoutVersionCodeMicroProcessorread-onlycurrentThe data layout version that allows the possibility to interpret stored data differently.
1.3.6.1.4.1.193.72.600.1.1.15.2.8ScalaridCheckSumMicroProcessorread-onlycurrentCRC32 Checksum of identification data structure for the MicroProcessor board.
1.3.6.1.4.1.193.72.600.1.1.15.3NodeanalogueFrontEndIdData
1.3.6.1.4.1.193.72.600.1.1.15.3.1ScalarproductNumberAnalogueFrontEndread-onlycurrentIndex number that identifies the AFE board.
1.3.6.1.4.1.193.72.600.1.1.15.3.2ScalarrevisionStateAnalogueFrontEndread-onlycurrentRevision State or 'R-state' declaring minor versions. For example: different types of components or new boot SW.
1.3.6.1.4.1.193.72.600.1.1.15.3.3ScalarfunctionDesignationAnalogueFrontEndread-onlycurrentNumber with reference to the handling and use of the product.
1.3.6.1.4.1.193.72.600.1.1.15.3.4ScalardateOfProductionAnalogueFrontEndread-onlycurrentManufacturing date, describing when the unit has been manufactured, in terms of a year, month and a day, as described below: Year code(0000 ..9999) - 2 bytes (…
1.3.6.1.4.1.193.72.600.1.1.15.3.5ScalardateOfRepairAnalogueFrontEndread-onlycurrentRepair date, declaring the year, month and day of the latest repair. The format is described below: Year code(0000 ..9999) - 2 bytes (LSB,MSB) Month (1..12)- 1…
1.3.6.1.4.1.193.72.600.1.1.15.3.6ScalarproductionSerialNumberAnalogueFrontEndread-onlycurrentUnique serial number, describing the product in terms of a manufacturing site code and a sequence number.
1.3.6.1.4.1.193.72.600.1.1.15.3.7ScalarlayoutVersionCodeAnalogueFrontEndread-onlycurrentThe data layout version that allows the possibility to interpret stored data differently.
1.3.6.1.4.1.193.72.600.1.1.15.3.8ScalaridCheckSumAnalogueFrontEndread-onlycurrentCRC32 Checksum of identification data structure for the Analogue Front End board.
1.3.6.1.4.1.193.72.600.1.1.15.4NodedcDcConverterIdData
1.3.6.1.4.1.193.72.600.1.1.15.4.1ScalarproductNumberDcDcConverterread-onlycurrentIndex number that identifies the DC-DC Converter board.
1.3.6.1.4.1.193.72.600.1.1.15.4.2ScalarrevisionStateDcDcConverterread-onlycurrentRevision State or 'R-state' declaring minor versions. For example: different types of components or new boot SW.
1.3.6.1.4.1.193.72.600.1.1.15.4.3ScalarfunctionDesignationDcDcConverterread-onlycurrentNumber with reference to the handling and use of the product.
1.3.6.1.4.1.193.72.600.1.1.15.4.4ScalardateOfProductionDcDcConverterread-onlycurrentManufacturing date, describing when the unit has been manufactured, in terms of a year, month and a day, as described below: Year code(0000 ..9999) - 2 bytes (…
1.3.6.1.4.1.193.72.600.1.1.15.4.5ScalardateOfRepairDcDcConverterread-onlycurrentRepair date, declaring the year, month and day of the latest repair. The format is described below: Year code(0000 ..9999) - 2 bytes (LSB,MSB) Month (1..12)- 1…
1.3.6.1.4.1.193.72.600.1.1.15.4.6ScalarproductionSerialNumberDcDcConverterread-onlycurrentUnique serial number, describing the product in terms of a manufacturing site code and a sequence number.
1.3.6.1.4.1.193.72.600.1.1.15.4.7ScalarlayoutVersionCodeDcDcConverterread-onlycurrentThe data layout version that allows the possibility to interpret stored data differently.
1.3.6.1.4.1.193.72.600.1.1.15.4.8ScalaridCheckSumDcDcConverterread-onlycurrentCRC32 Checksum of identification data for the DC-DC Converter board.
1.3.6.1.4.1.193.72.600.1.1.16ScalarsntpServerIPread-writecurrentThe IP address of SNTP server used for time synchronization.
1.3.6.1.4.1.193.72.600.1.1.17ScalarsnmpKeepAliveTimerTimeread-writecurrentThe interval between SNMP KeepAlive checks.
1.3.6.1.4.1.193.72.600.1.1.18ScalarallowBroadcastToDuxread-writecurrentEnables/disables broadcast to DUX (broadcast beacons). When the IP DSLAM is restarted one broadcast to DUX is always sent, hereafter allowBroadcastToDux determ…
1.3.6.1.4.1.193.72.600.1.1.20NodepeaMultilink
1.3.6.1.4.1.193.72.600.1.1.20.1ScalarpeaMultilinkModeread-writecurrentThis defines the mode the multiple network-side links operate in. singleLink(1) - only one link is used for active data transfer. This is the only possible val…
1.3.6.1.4.1.193.72.600.1.1.20.2ScalarpeaMultilinkPreferredInterfaceread-onlycurrentShows the index of the interface (link) selected for traffic forwarding whenever there is no other explicit indication on which one to choose. The interface is…
1.3.6.1.4.1.193.72.600.1.1.20.3TablepeaMultilinkInterfaceTablenot-accessiblecurrentThis is a table of interfaces (links) on the network-side. The table is indexed by the same interface numbers as used in the IF-MIB (1-based).
1.3.6.1.4.1.193.72.600.1.1.20.3.1RowpeaMultilinkInterfaceEntrynot-accessiblecurrentThis is an entry of the multilinkInterfaceTable
1.3.6.1.4.1.193.72.600.1.1.20.3.1.1ColumnpeaMultilinkInterfaceIndexnot-accessiblecurrentThis is the index to the multilinkInterfaceTable. The values are the same as used in the IF-MIB (1-based).
1.3.6.1.4.1.193.72.600.1.1.20.3.1.2ColumnpeaMultilinkIsForwardingread-onlycurrentThis shows if the corresponding interface (link) is forwarding traffic - true(1) or not - false(2). An interface that is not forwarding may still carry some se…
1.3.6.1.4.1.193.72.600.1.1.20.3.1.3ColumnpeaMultilinkIsUpread-onlycurrentThis shows if the corresponding interface (link) is up true(1) or down - false(2). The true(1) value is returned if the ifOperState of the corresponding port i…
1.3.6.1.4.1.193.72.600.1.1.20.4ScalarpeaMultilinkForceManagementToUsePreferredInterfaceread-writecurrentSetting this value to 'enabled (1)' forces the management traffic to be sent on the interface towards the Active ECN thereby overruling the RSTP protocol for m…
1.3.6.1.4.1.193.72.600.1.1.21ScalarcomboConnectorread-onlycurrentTell if a combo connector is mounted for this board.
1.3.6.1.4.1.193.72.600.1.1.22ScalarblockUnitread-writecurrentBlock this unit. When blocked: - no user traffic is carried out - no alarms are issued - it does not allow any configuration Getting a card out of blocked stat…
1.3.6.1.4.1.193.72.600.1.2NodecommonTraps
1.3.6.1.4.1.193.72.600.1.2.0Nodetraps
1.3.6.1.4.1.193.72.600.1.2.1NodetrapsParameters
1.3.6.1.4.1.193.72.600.1.5NodeifObjects
1.3.6.1.4.1.193.72.600.1.6NodeifNotifications
1.3.6.1.4.1.193.72.600.1.6.0NodeifNotificationTypes
1.3.6.1.4.1.193.72.600.1.7NodepeaEquipmentMibGroups
1.3.6.1.4.1.193.72.600.1.8Nodesnmpv2Notifications
1.3.6.1.4.1.193.72.600.1.8.0Nodesnmpv2NotificationsTypes
1.3.6.1.4.1.193.72.600.1.9NodebridgeNotifications
1.3.6.1.4.1.193.72.600.1.9.0NodebridgeNotificationsTypes
1.3.6.1.4.1.193.72.600.1.10NodermonNotifications
1.3.6.1.4.1.193.72.600.1.10.0NodermonNotificationsTypes
Type Definitions
NameSyntaxStatusDescription
PhyModeTypeOCTET STRING (SIZE (1))currentRepresent the Ethernet PHY Mode.