MIB Viewer

PEA-EQUIPMENT-IPDSLAM

145 objects
The IP DSLAM software supports a number of standard and proprietary MIBs. This MIB module defines objects for reading out system specific information about the IP DSLAM and the control entries for restarting the IP DSLAM, for setting the alarm filter and for controlling the LEDs.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.193.72.300.1IdentitypeaEquipmentIpDslamThe IP DSLAM software supports a number of standard and proprietary MIBs. This MIB module defines objects for reading out system specific information about the…
1.3.6.1.4.1.193.72.300.1.1NodepeaEquipmentIpDslamObjects
1.3.6.1.4.1.193.72.300.1.1.1ScalarcfgVersionread-writedeprecatedThe CfgVersion will initially be zero, but is set to the version number defined in the configuration file received from the tftp server at system start-up. The…
1.3.6.1.4.1.193.72.300.1.1.2ScalarrestartModemPoolread-writedeprecatedWhen set to 'restart' the IP DSLAM restarts, which includes loading the SW image and configuration data from the server. In this way a new SW version can be lo…
1.3.6.1.4.1.193.72.300.1.1.3NodetemperatureControlStatus
1.3.6.1.4.1.193.72.300.1.1.3.1ScalartemperatureControlStateread-onlydeprecatedThe state of the temperature control can be: 0 - Low 1 - Normal 2 - High 3 - TooHigh
1.3.6.1.4.1.193.72.300.1.1.3.2ScalartemperatureValueread-onlydeprecatedThe temperature value in the IP DSLAM in grade Celsius.
1.3.6.1.4.1.193.72.300.1.1.3.3NodefansStatus
1.3.6.1.4.1.193.72.300.1.1.3.3.1ScalarfanGreenStatusread-onlydeprecatedThe status of the fan which is placed closest to the green LED.
1.3.6.1.4.1.193.72.300.1.1.3.3.2ScalarfanRedStatusread-onlydeprecatedThe status of the fan which is placed closest to the red LED.
1.3.6.1.4.1.193.72.300.1.1.3.3.3ScalarfanGreenSpeedread-onlydeprecatedThe speed of the fan which is placed closest to the green LED measured in rpm (rotations per minute).
1.3.6.1.4.1.193.72.300.1.1.3.3.4ScalarfanRedSpeedread-onlydeprecatedThe speed of the fan which is placed closest to the red LED measured in rpm (rotations per minute).
1.3.6.1.4.1.193.72.300.1.1.4NodeledControl
1.3.6.1.4.1.193.72.300.1.1.4.1ScalarledsAlternativeBlinkread-writedeprecatedWhen the ledsAlternativeBlink is set to ON(1) the LEDs will start to blink alternatively.
1.3.6.1.4.1.193.72.300.1.1.5ScalaronlyShowEthernetInterfaceread-writedeprecatedWhen set to ON(1) only the Ethernet interface is visible (RFC1233/RFC2233). When is set to OFF(0) the ATM and software loop back interfaces are also visible.
1.3.6.1.4.1.193.72.300.1.1.7NodemainProcessor
1.3.6.1.4.1.193.72.300.1.1.7.1ScalarmpProcessorLoadread-onlydeprecatedThe percentage of time that the main processor was not idle. Average over 10 seconds. (almost like hrProcessorLoad in RFC1514).
1.3.6.1.4.1.193.72.300.1.1.7.2ScalarmpMemFreeread-onlydeprecatedThe amount of free memory on main processor in percent.
1.3.6.1.4.1.193.72.300.1.1.7.3ScalarmpMemFreeBytesread-onlydeprecatedThe amount of free memory on main processor in bytes.
1.3.6.1.4.1.193.72.300.1.1.7.4ScalarmpMemBuffersUsedread-onlydeprecatedThe total number of memory buffers currently used (Ethernet, ATM & local IP-stack).
1.3.6.1.4.1.193.72.300.1.1.8ScalarsystemIdentificationread-onlydeprecatedThis value includes the full name and version identification of the IP DSLAM software.
1.3.6.1.4.1.193.72.300.1.1.9NodealarmFilter
1.3.6.1.4.1.193.72.300.1.1.9.1ScalarcommunicationsAlarmFilterread-writedeprecatedThis alarm filter will filter out all communication alarms with lower severity than the selected. E.g. Selecting minor (1) would filter out all alarms with war…
1.3.6.1.4.1.193.72.300.1.1.9.2ScalarenvironmentAlarmFilterread-writedeprecatedThis alarm filter will filter out all environment alarms with lower severity than the selected. E.g. Selecting minor (1) would filter out all alarms with warni…
1.3.6.1.4.1.193.72.300.1.1.9.3ScalarequipmentAlarmFilterread-writedeprecatedThis alarm filter will filter out all equipment alarms with lower severity than the selected. E.g. Selecting minor (1) would filter out all alarms with warning…
1.3.6.1.4.1.193.72.300.1.1.9.4ScalarprocessingAlarmFilterread-writedeprecatedThis alarm filter will filter out all processing alarms with lower severity than the selected. E.g. Selecting minor (1) would filter out all alarms with warnin…
1.3.6.1.4.1.193.72.300.1.1.9.5ScalarqualityOfServiceAlarmFilterread-writedeprecatedThis alarm filter will filter out all quality alarms with lower severity than the selected. E.g. Selecting minor (1) would filter out all alarms with warning (…
1.3.6.1.4.1.193.72.300.1.1.10NodeidentificationData
1.3.6.1.4.1.193.72.300.1.1.10.1NodeipdslamIdData
1.3.6.1.4.1.193.72.300.1.1.10.1.1ScalarproductNumberMPread-onlydeprecatedIndex number that identifies the IP DSLAM hardware unit.
1.3.6.1.4.1.193.72.300.1.1.10.1.2ScalarrevisionStateMPread-onlydeprecatedRevision State or 'R-state' declaring minor versions. E.g. different types of components or new boot SW.
1.3.6.1.4.1.193.72.300.1.1.10.1.3ScalarfunctionDesignationMPread-onlydeprecatedNumber with reference to the handling and use of the product.
1.3.6.1.4.1.193.72.300.1.1.10.1.4ScalardateOfProductionMPread-onlydeprecatedManufacturing date, describing when the unit has been manufactured, in terms of a year, month and a day, as described below: Year code(0000 ..9999) - 2 bytes (…
1.3.6.1.4.1.193.72.300.1.1.10.1.5ScalardateOfRepairMPread-onlydeprecatedRepair date, declaring the year, month and day of the latest repair. The format is described below: Year code(0000 ..9999) - 2 bytes (LSB,MSB) Month (1..12)- 1…
1.3.6.1.4.1.193.72.300.1.1.10.1.6ScalarproductionSerialNumberMPread-onlydeprecatedUnique serial number, describing the product in terms of a manufacturing site code and a sequence number.
1.3.6.1.4.1.193.72.300.1.1.10.1.7ScalarlayoutVersionCodeMPread-onlydeprecatedThe data layout version that allows the possibility to interpret stored data differently.
1.3.6.1.4.1.193.72.300.1.1.10.1.8ScalaridCheckSumMPread-onlydeprecatedCRC32 Checksum of identification data structure of the IP DSLAM.
1.3.6.1.4.1.193.72.300.1.1.10.2NodedupBoardIdData
1.3.6.1.4.1.193.72.300.1.1.10.2.1ScalarproductNumberDUPread-onlydeprecatedIndex number that identifies the DUP board.
1.3.6.1.4.1.193.72.300.1.1.10.2.2ScalarrevisionStateDUPread-onlydeprecatedRevision State or 'R-state' declaring minor versions. E.g. different types of components or new boot SW.
1.3.6.1.4.1.193.72.300.1.1.10.2.3ScalarfunctionDesignationDUPread-onlydeprecatedNumber with reference to the handling and use of the product.
1.3.6.1.4.1.193.72.300.1.1.10.2.4ScalardateOfProductionDUPread-onlydeprecatedManufacturing date, describing when the unit has been manufactured, in terms of a year, month and a day, as described below: Year code(0000 ..9999) - 2 bytes (…
1.3.6.1.4.1.193.72.300.1.1.10.2.5ScalardateOfRepairDUPread-onlydeprecatedRepair date, declaring the year, month and day of the latest repair. he format is described below: Year code(0000 ..9999) - 2 bytes (LSB,MSB) Month (1..12)- 1 …
1.3.6.1.4.1.193.72.300.1.1.10.2.6ScalarproductionSerialNumberDUPread-onlydeprecatedUnique serial number, describing the product in terms of a manufacturing site code and a sequence number.
1.3.6.1.4.1.193.72.300.1.1.10.2.7ScalarlayoutVersionCodeDUPread-onlydeprecatedThe data layout version that allows the possibility to interpret stored data differently.
1.3.6.1.4.1.193.72.300.1.1.10.2.8ScalaridCheckSumDUPread-onlydeprecatedCRC32 Checksum of identification data structure for the DUP board.
1.3.6.1.4.1.193.72.300.1.1.10.3NodedafeBoardIdData
1.3.6.1.4.1.193.72.300.1.1.10.3.1ScalarproductNumberDAFEread-onlydeprecatedIndex number that identifies the DAFE board.
1.3.6.1.4.1.193.72.300.1.1.10.3.2ScalarrevisionStateDAFEread-onlydeprecatedRevision State or 'R-state' declaring minor versions. E.g. different types of components or new boot SW.
1.3.6.1.4.1.193.72.300.1.1.10.3.3ScalarfunctionDesignationDAFEread-onlydeprecatedNumber with reference to the handling and use of the product.
1.3.6.1.4.1.193.72.300.1.1.10.3.4ScalardateOfProductionDAFEread-onlydeprecatedManufacturing date, describing when the unit has been manufactured, in terms of a year, month and a day, as described below: Year code(0000 ..9999) - 2 bytes (…
1.3.6.1.4.1.193.72.300.1.1.10.3.5ScalardateOfRepairDAFEread-onlydeprecatedRepair date, declaring the year, month and day of the latest repair. The format is described below: Year code(0000 ..9999) - 2 bytes (LSB,MSB) Month (1..12)- 1…
1.3.6.1.4.1.193.72.300.1.1.10.3.6ScalarproductionSerialNumberDAFEread-onlydeprecatedUnique serial number, describing the product in terms of a manufacturing site code and a sequence number.
1.3.6.1.4.1.193.72.300.1.1.10.3.7ScalarlayoutVersionCodeDAFEread-onlydeprecatedThe data layout version that allows the possibility to interpret stored data differently.
1.3.6.1.4.1.193.72.300.1.1.10.3.8ScalaridCheckSumDAFEread-onlydeprecatedCRC32 Checksum of identification data structure for the DAFE board.
1.3.6.1.4.1.193.72.300.1.1.10.4NodeddcBoardIdData
1.3.6.1.4.1.193.72.300.1.1.10.4.1ScalarproductNumberDDCread-onlydeprecatedIndex number that identifies the DDC board.
1.3.6.1.4.1.193.72.300.1.1.10.4.2ScalarrevisionStateDDCread-onlydeprecatedRevision State or 'R-state' declaring minor versions. E.g. different types of components or new boot SW.
1.3.6.1.4.1.193.72.300.1.1.10.4.3ScalarfunctionDesignationDDCread-onlydeprecatedNumber with reference to the handling and use of the product.
1.3.6.1.4.1.193.72.300.1.1.10.4.4ScalardateOfProductionDDCread-onlydeprecatedManufacturing date, describing when the unit has been manufactured, in terms of a year, month and a day, as described below: Year code(0000 ..9999) - 2 bytes (…
1.3.6.1.4.1.193.72.300.1.1.10.4.5ScalardateOfRepairDDCread-onlydeprecatedRepair date, declaring the year, month and day of the latest repair. The format is described below: Year code(0000 ..9999) - 2 bytes (LSB,MSB) Month (1..12)- 1…
1.3.6.1.4.1.193.72.300.1.1.10.4.6ScalarproductionSerialNumberDDCread-onlydeprecatedUnique serial number, describing the product in terms of a manufacturing site code and a sequence number.
1.3.6.1.4.1.193.72.300.1.1.10.4.7ScalarlayoutVersionCodeDDCread-onlydeprecatedThe data layout version that allows the possibility to interpret stored data differently.
1.3.6.1.4.1.193.72.300.1.1.10.4.8ScalaridCheckSumDDCread-onlydeprecatedCRC32 Checksum of identification data for the DDC board.
1.3.6.1.4.1.193.72.300.1.1.10.5NodedifBoardIdData
1.3.6.1.4.1.193.72.300.1.1.10.5.1ScalarproductNumberDIFread-onlycurrentIndex number that identifies the DIF board.
1.3.6.1.4.1.193.72.300.1.1.10.5.2ScalarrevisionStateDIFread-onlycurrentRevision State or 'R-state' declaring minor versions. E.g. different types of components or new boot SW.
1.3.6.1.4.1.193.72.300.1.1.10.5.3ScalarfunctionDesignationDIFread-onlycurrentNumber with reference to the handling and use of the product.
1.3.6.1.4.1.193.72.300.1.1.10.5.4ScalardateOfProductionDIFread-onlycurrentManufacturing date, describing when the unit has been manufactured, in terms of a year, month and a day, as described below: Year code(0000 ..9999) - 2 bytes (…
1.3.6.1.4.1.193.72.300.1.1.10.5.5ScalardateOfRepairDIFread-onlycurrentRepair date, declaring the year, month and day of the latest repair. The format is described below: Year code(0000 ..9999) - 2 bytes (LSB,MSB) Month (1..12)- 1…
1.3.6.1.4.1.193.72.300.1.1.10.5.6ScalarproductionSerialNumberDIFread-onlycurrentUnique serial number, describing the product in terms of a manufacturing site code and a sequence number.
1.3.6.1.4.1.193.72.300.1.1.10.5.7ScalarlayoutVersionCodeDIFread-onlycurrentThe data layout version that allows the possibility to interpret stored data differently.
1.3.6.1.4.1.193.72.300.1.1.10.5.8ScalaridCheckSumDIFread-onlycurrentCRC32 Checksum of identification data for the DIF board.
1.3.6.1.4.1.193.72.300.1.1.11NodeconfigurationData
1.3.6.1.4.1.193.72.300.1.1.11.1ScalarlocalMacAddrMPread-onlydeprecatedUnique MAC address of the IP DSLAM.
1.3.6.1.4.1.193.72.300.1.1.11.2ScalarphyModeMPread-writedeprecatedEthernet PHY Mode setting. The Phy Mode is coded as a bitfield: * Bit 0: Auto-negotiation. If set, auto-negotiation is OFF else ON. * Bit 2: Full Duplex contro…
1.3.6.1.4.1.193.72.300.1.1.11.3ScalarwatchDogEnableMPread-onlydeprecatedEnabling of the HW Watchdog. If 0 (zero), the watchdog is OFF, else the watchdog is ON.
1.3.6.1.4.1.193.72.300.1.1.11.5ScalarvlanIdMPread-writedeprecatedThe VLAN ID setting for the management VLAN.
1.3.6.1.4.1.193.72.300.1.1.11.6ScalarvlanPrioMPread-writedeprecatedSpecifies the IEEE 802.1Q priority used for the management VLAN.
1.3.6.1.4.1.193.72.300.1.1.11.7ScalarvlanTaggingMPread-writedeprecatedIf 0, VLAN tagging is off, meaning that VLAN is not used. If 1, VLAN tagging is used, with the given ID and Prio.
1.3.6.1.4.1.193.72.300.1.1.11.8ScalarbootStringMPread-onlydeprecatedText commands for the bootloader.
1.3.6.1.4.1.193.72.300.1.1.12ScalarbootSwIdentificationread-onlydeprecatedThis value includes the full name and version identification of the BOOT software.
1.3.6.1.4.1.193.72.300.1.1.13NodeproductDescription
1.3.6.1.4.1.193.72.300.1.1.13.1ScalarnumberOfLinesread-onlycurrentNumber of subscriber lines supported by this IP DSLAM.
1.3.6.1.4.1.193.72.300.1.1.14NoderemoteStorage
1.3.6.1.4.1.193.72.300.1.1.14.1ScalarremoteStorageFTPServerIPMPread-writecurrentThe IP Address of FTP server to be used with the remote storage area. The value can be any IP address
1.3.6.1.4.1.193.72.300.1.1.14.2ScalarremoteStorageFilePathMPread-writecurrentThe path to the remote storage file. The path should be relatetive to home of the FTP server. (I.e. Files/MPRemoteStorageFiles where the 'Files' directory is c…
1.3.6.1.4.1.193.72.300.1.1.14.3ScalarremoteStorageFTPUserMPread-writecurrentThe user name which should be used by the IP DSLAM to access the remote storage ftp server.
1.3.6.1.4.1.193.72.300.1.1.14.4ScalarremoteStorageFTPPasswordMPread-writecurrentThe password which should be used by the IP DSLAM to access the remote storage ftp server.
1.3.6.1.4.1.193.72.300.1.1.14.5ScalarremoteStorageTrafficInfoTimeMPread-writecurrentThe time interval for periodically triggering a backup of the remote storage file. All traffic counters will be backed up with remote storage. This includes to…
1.3.6.1.4.1.193.72.300.1.1.14.6ScalarremoteStorageTrafficInfoSizeMPread-writecurrentThe size interval for triggering a backup of the remote storage file. Whenever x MBytes has been transfered on any PVC since last backup all traffic counters w…
1.3.6.1.4.1.193.72.300.1.1.15Nodemultilink
1.3.6.1.4.1.193.72.300.1.1.15.1ScalarmultilinkModeread-writecurrentThis defines the mode the multiple network-side links operate in. singleLink(1) - only one link is used for active data transfer. This is the only possible val…
1.3.6.1.4.1.193.72.300.1.1.15.2ScalarmultilinkPreferredInterfaceread-writecurrentShows the index of the interface (link) selected for traffic forwarding whenever there is no other explicit indication on which one to choose. The interface is…
1.3.6.1.4.1.193.72.300.1.1.15.3TablemultilinkInterfaceTablenot-accessiblecurrentThis is a table of interfaces (links) on the network-side. The table is indexed by the same interface numbers as used in the IF-MIB (1-based).
1.3.6.1.4.1.193.72.300.1.1.15.3.1RowmultilinkInterfaceEntrynot-accessiblecurrentThis is an entry of the multilinkInterfaceTable
1.3.6.1.4.1.193.72.300.1.1.15.3.1.1ColumnmultilinkInterfaceIndexnot-accessiblecurrentThis is the index to the multilinkInterfaceTable. The values are the same as used in the IF-MIB (1-based).
1.3.6.1.4.1.193.72.300.1.1.15.3.1.2ColumnmultilinkIsForwardingread-onlycurrentThis shows if the corresponding interface (link) is forwarding traffic - true(1) or not - false(2). An interface that is not forwarding may still carry some se…
1.3.6.1.4.1.193.72.300.1.1.15.3.1.3ColumnmultilinkIsUpread-onlycurrentThis shows if the corresponding interface (link) is up true(1) or down - false(2). The true(1) value is returned if the ifOperState of the corresponding port i…
1.3.6.1.4.1.193.72.300.1.1.15.4ScalarmultilinkForceManagementToUsePreferredInterfaceread-writecurrentSetting this value to 'enabled (1)' forces the management traffic to be sent on the interface towards the Active ECN thereby overruling the RSTP protocol for m…
1.3.6.1.4.1.193.72.300.1.2NodepeaEquipmentIpDslamTraps
1.3.6.1.4.1.193.72.300.1.2.0Nodetraps
1.3.6.1.4.1.193.72.300.1.2.0.1NotificationtemperatureTooHighdeprecatedThe temperature is too high and has increased above a fixed threshold value. The high temperature value is probably caused by fan failure or high environment t…
1.3.6.1.4.1.193.72.300.1.2.0.2NotificationtemperatureTooHighCeasingdeprecatedThe too high temperature has ceased and has decreased below a fixed threshold value in the normal working area. For the IP DSLAM the lines are brought into ser…
1.3.6.1.4.1.193.72.300.1.2.0.4NotificationstateEventErrordeprecatedA state/event SW error has been detected on the device. This trap is seen if the IPDSLAM is discarding a message that it did not know how to handle. This kind …
1.3.6.1.4.1.193.72.300.1.2.0.5NotificationnonFatalSoftwareErrordeprecatedA non-fatal SW error has been detected on the device. This type of software error is normally not fatal for your system, It could be a configuration error or a…
1.3.6.1.4.1.193.72.300.1.2.0.6NotificationfatalSoftwareErrordeprecatedA fatal SW error has been detected on your device. The device will now restart in order to recover. This type of error is very serious and if it is seen in you…
1.3.6.1.4.1.193.72.300.1.2.0.7NotificationconfigurationFileErrordeprecatedThe configuration file which the device is using failed to pass or load. Corrective Actions: - Check that the device can reach the server where the configurati…
1.3.6.1.4.1.193.72.300.1.2.0.8NotificationmodemPoolRestartAlarmdeprecatedThe IP DSLAM has restarted. The post mortem information will indicate the reason for the restart. If the device has restarted from an unknown reason, then it i…
1.3.6.1.4.1.193.72.300.1.2.0.9NotificationfanGreenFailuredeprecatedIndicates that the fan located near to the green LED has failed. This means that the fan control cannot secure that the temperature is kept in the normal state…
1.3.6.1.4.1.193.72.300.1.2.0.10NotificationfanGreenCeasingdeprecatedIndicates the ceasing of the fan, which is located near to the green LED. Deprecated from: EDA 1.1 R2A Parameters 1: Managed object class IPDSLAM 2: Managed ob…
1.3.6.1.4.1.193.72.300.1.2.0.11NotificationfanRedFailuredeprecatedIndicates that the fan located near to the red LED has failed, This means that the fan control cannot secure that the temperature is kept in the normal state i…
1.3.6.1.4.1.193.72.300.1.2.0.12NotificationfanRedCeasingdeprecatedIndicates the ceasing of the fan which is located near to the red LED. Deprecated from: EDA 1.1 R2A Parameters 1: Managed object class IPDSLAM 2: Managed objec…
1.3.6.1.4.1.193.72.300.1.2.0.13NotificationidDataReadErrordeprecatedThis alarm indicates that the identification data the device has in flash memory is corrupted. Identification data could be parameters like 'product number', '…
1.3.6.1.4.1.193.72.300.1.2.0.14NotificationcfgDataReadErrordeprecatedThis alarm indicates that the configuration data it has in flash is corrupted. Configuration data could be parameters like 'local mac address', 'phy mode', 'vl…
1.3.6.1.4.1.193.72.300.1.2.0.15NotificationwriteFlashErrordeprecatedIndicates that an error occurred during the writing to the flash memory. Corrective Actions: - Try to restart the device and if the error keeps appearing then …
1.3.6.1.4.1.193.72.300.1.2.0.16NotificationbothFansFailuredeprecatedIndicates that both fans on the device have failed. This means that the fan control cannot secure that the temperature is kept in the normal state in the worst…
1.3.6.1.4.1.193.72.300.1.2.0.17NotificationbothFansCeasingdeprecatedIndicates that at least one of the fans is working again. This means that the fan control cannot secure that the temperature is kept in the normal state in the…
1.3.6.1.4.1.193.72.300.1.2.0.18NotificationmodemPoolTypeUnknowndeprecatedIndicates that the device type can not be identified. The product number and revision state are either unkonwn or corrupted. The application software cannot ha…
1.3.6.1.4.1.193.72.300.1.2.0.19NotificationfanGreenLowPerformancedeprecatedIndicates that the fan located near the green LED has a low performance. This means that the fan control cannot secure that the temperature is kept in the norm…
1.3.6.1.4.1.193.72.300.1.2.0.20NotificationfanGreenLowPerformanceCeasingdeprecatedIndicates that the low performance of the green fan, which is the one located near the green LED, has ceased. If this ceasing alarm is seen frequently on a dev…
1.3.6.1.4.1.193.72.300.1.2.0.21NotificationfanRedLowPerformancedeprecatedIndicates that the fan located near the red LED has a low performance. This means that the fan control cannot secure that the temperature is kept in the normal…
1.3.6.1.4.1.193.72.300.1.2.0.22NotificationfanRedLowPerformanceCeasingdeprecatedIndicates that the low performance of the red fan, which is the one located near the red LED, has ceased. If this ceasing alarm is seen frequently on a device …
1.3.6.1.4.1.193.72.300.1.2.0.23NotificationtemperatureCloseToTooHighdeprecatedIndicates the temperature is close to the too high value. This alarm should be considered as a warning alarm that is received a while before the high temperatu…
1.3.6.1.4.1.193.72.300.1.2.0.24NotificationtemperatureCloseToTooHighCeasingdeprecatedIndicates that the temperatureCloseToTooHigh alarm is no longer active. The temperature has been successfully reduced to level where the device can work normal…
1.3.6.1.4.1.193.72.300.1.2.1NodetrapsParameters
1.3.6.1.4.1.193.72.300.1.2.1.1ScalarprocessNameaccessible-for-notifydeprecatedThe name of the process which sent the alarm.
1.3.6.1.4.1.193.72.300.1.2.1.2ScalarprocessStateaccessible-for-notifydeprecatedThe state of the process which sent the alarm.
1.3.6.1.4.1.193.72.300.1.2.1.3ScalarfileNameaccessible-for-notifydeprecatedThe file name from where the alarm was sent
1.3.6.1.4.1.193.72.300.1.2.1.4ScalarlineNoaccessible-for-notifydeprecatedThe line number in the file indicated by fileName, from where the alarm was sent
1.3.6.1.4.1.193.72.300.1.2.1.5ScalarsenderTaskaccessible-for-notifydeprecatedIndicates the name of the task which sent the message causing a stateEventErrror.
1.3.6.1.4.1.193.72.300.1.2.1.6ScalarerrorCodeaccessible-for-notifydeprecatedAdditional error information.
1.3.6.1.4.1.193.72.300.1.2.1.7ScalarpostMortemInformationaccessible-for-notifydeprecatedIndicates the reason of the restart.
1.3.6.1.4.1.193.72.300.1.2.1.8ScalarerrorDataaccessible-for-notifydeprecatedAdditional data related to the error.
1.3.6.1.4.1.193.72.300.1.2.1.9ScalarmessageIdaccessible-for-notifydeprecatedMessage ID of the last received message. E.g. the ID of the message causing a state event error.
1.3.6.1.4.1.193.72.300.1.2.1.10ScalarmessageDataaccessible-for-notifydeprecatedMessage content of the last received message. E.g. the content of the message causing a state event error.
1.3.6.1.4.1.193.72.300.1.2.1.11ScalarhwUnitaccessible-for-notifydeprecatedIdentifies the HW unit which has the identification data corrupted into FLASH.
1.3.6.1.4.1.193.72.300.1.2.1.12ScalarcfgDataaccessible-for-notifydeprecatedIdentifies the corrupted configuration data read from FLASH for the IP DSLAM.
1.3.6.1.4.1.193.72.300.1.2.1.13ScalaridOrCfgDataaccessible-for-notifydeprecatedIdentifies during which data writing occured an error.
1.3.6.1.4.1.193.72.300.1.3NodepeaEquipmentIpDslamObjectsGroups
1.3.6.1.4.1.193.72.300.1.3.1GrouppeaEquipmentIpDslamDeprecatedObjectsGroupdeprecatedObjects for the peaEquipmentIpDslamObjects Group
1.3.6.1.4.1.193.72.300.1.3.2GrouppeaEquipmentIpDslamCurrentObjectsGroupcurrentObjects for the peaEquipmentIpDslamObjects Group
1.3.6.1.4.1.193.72.300.1.4NodepeaEquipmentIpDslamTrapsGroups
1.3.6.1.4.1.193.72.300.1.4.1GrouppeaEquipmentIpDslamDeprecatedTrapsGroupdeprecatedDeprecated Notifications Group
Type Definitions
NameSyntaxStatusDescription
PhyModeTypeOCTET STRING (SIZE (1))currentRepresent the Ethernet PHY Mode.