PEA_EQUIPMENT
136 objects
The public ethernet access software supports a number of standard and proprietary MIBs. This MIB module defines objects for reading/writing common equipment information.
Imported Objects
| PEA-SMI | pea |
| PEM-STANDARD | 733 header for the traps managedObjectClass eventTime eventTypePem managedObjectInstance perceivedSeverity probableCause sequenceNumber |
| SNMPv2-TC | MacAddress |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.193.72.600.1 | IdentitypeaEquipment | The public ethernet access software supports a number of standard and proprietary MIBs. This MIB module defines objects for reading/writing common equipment in… | ||
| 1.3.6.1.4.1.193.72.600.1.1 | NodecommonObjects | |||
| 1.3.6.1.4.1.193.72.600.1.1.1 | Nodeversions | |||
| 1.3.6.1.4.1.193.72.600.1.1.1.1 | ScalarsysId | read-only | current | This value includes the full name and version identification of the device software. |
| 1.3.6.1.4.1.193.72.600.1.1.1.2 | ScalarbootSwId | read-only | current | This value includes the full name and version identification of the BOOT software. |
| 1.3.6.1.4.1.193.72.600.1.1.1.3 | ScalarcfgVer | read-write | current | The CfgVer will initially be zero, but is set to the version number defined in the configuration file received from the tftp server at system start-up. The man… |
| 1.3.6.1.4.1.193.72.600.1.1.1.4 | ScalaractiveSwInfo | read-only | current | This value represents the software version of the active software part of the device. |
| 1.3.6.1.4.1.193.72.600.1.1.1.5 | ScalarpassiveSwInfo | read-only | current | This value represents the software version of the passive software part of the device. |
| 1.3.6.1.4.1.193.72.600.1.1.2 | NodemainProcessor | |||
| 1.3.6.1.4.1.193.72.600.1.1.2.1 | ScalarprocessorLoad | read-only | current | The percentage of time that the main processor was not idle. Average over 10 seconds. (almost like hrProcessorLoad in RFC1514). |
| 1.3.6.1.4.1.193.72.600.1.1.2.2 | ScalarmemFree | read-only | current | The amount of free memory on main processor in percent. |
| 1.3.6.1.4.1.193.72.600.1.1.2.3 | ScalarmemFreeBytes | read-only | current | The amount of free memory on main processor in bytes. |
| 1.3.6.1.4.1.193.72.600.1.1.2.4 | ScalarmemBuffersUsed | read-only | current | The total number of memory buffers currently used (Ethernet, ATM & local IP-stack). |
| 1.3.6.1.4.1.193.72.600.1.1.3 | Nodetemperature | |||
| 1.3.6.1.4.1.193.72.600.1.1.3.1 | ScalartempControlState | read-only | current | The state of the temperature control can be: 0 - Low 1 - Normal 2 - High 3 - TooHigh |
| 1.3.6.1.4.1.193.72.600.1.1.3.2 | ScalartempValue | read-only | current | The temperature value in the device in grade Celsius. |
| 1.3.6.1.4.1.193.72.600.1.1.4 | NodefansStatus | |||
| 1.3.6.1.4.1.193.72.600.1.1.4.1 | ScalargreenFanStatus | read-only | current | The status of the fan which is placed closest to the green LED. For ESN310, green fan is the fan place to the front |
| 1.3.6.1.4.1.193.72.600.1.1.4.2 | ScalarredFanStatus | read-only | current | The status of the fan which is placed closest to the red LED. For ESN310, red fan is the fan place to the back |
| 1.3.6.1.4.1.193.72.600.1.1.4.3 | ScalargreenFanSpeed | read-only | current | The speed of the fan, which is placed closest to the green LED, measured in rpm (rotations per minute). |
| 1.3.6.1.4.1.193.72.600.1.1.4.4 | ScalarredFanSpeed | read-only | current | The speed of the fan, which is placed closest to the red LED, measured in rpm (rotations per minute). |
| 1.3.6.1.4.1.193.72.600.1.1.5 | NodealarmFilter | |||
| 1.3.6.1.4.1.193.72.600.1.1.5.1 | ScalarcomAlarmFilter | read-write | current | This alarm filter will filter out all communication alarms with lower severity than the selected. E.g. Selecting minor (1) would filter out all alarms with war… |
| 1.3.6.1.4.1.193.72.600.1.1.5.2 | ScalarenvAlarmFilter | read-write | current | This alarm filter will filter out all environment alarms with lower severity than the selected. E.g. Selecting minor (1) would filter out all alarms with warni… |
| 1.3.6.1.4.1.193.72.600.1.1.5.3 | ScalarequipAlarmFilter | read-write | current | This alarm filter will filter out all equipment alarms with lower severity than the selected. E.g. Selecting minor (1) would filter out all alarms with warning… |
| 1.3.6.1.4.1.193.72.600.1.1.5.4 | ScalarprocessAlarmFilter | read-write | current | This alarm filter will filter out all processing alarms with lower severity than the selected. E.g. Selecting minor (1) would filter out all alarms with warnin… |
| 1.3.6.1.4.1.193.72.600.1.1.5.5 | ScalarqosAlarmFilter | read-write | current | This alarm filter will filter out all quality alarms with lower severity than the selected. E.g. Selecting minor (1) would filter out all alarms with warning (… |
| 1.3.6.1.4.1.193.72.600.1.1.5.6 | ScalaralarmFilterThres | read-write | current | The threshold value indicates how many alarms that can be filtered by the device in the time interval indicated by the alarmFilterInterval parameter before an … |
| 1.3.6.1.4.1.193.72.600.1.1.5.7 | ScalaralarmFilterInterval | read-write | current | The value of this parameter indicates the time interval in which the device can filter a number of alarms indicated by the alarmFilterThres parameter before an… |
| 1.3.6.1.4.1.193.72.600.1.1.6 | NodeconfigurationData | |||
| 1.3.6.1.4.1.193.72.600.1.1.6.1 | ScalarlocalMacAddr | read-only | current | Unique MAC address of the device. |
| 1.3.6.1.4.1.193.72.600.1.1.6.2 | ScalarphyMode | read-write | current | Ethernet PHY Mode setting. The Phy Mode is coded as a bitfield: � Bit 0: Auto-negotiation. If set, auto-negotiation is OFF else ON. � Bit 2: Full Duplex co… |
| 1.3.6.1.4.1.193.72.600.1.1.6.3 | ScalarwatchDogEnable | read-only | current | Enabling of the HW Watchdog. If 0 (zero), the watchdog is OFF, else the watchdog is ON. |
| 1.3.6.1.4.1.193.72.600.1.1.6.5 | ScalarvlanId | read-write | current | The VLAN ID setting for the management VLAN. |
| 1.3.6.1.4.1.193.72.600.1.1.6.6 | ScalarvlanPrio | read-write | current | Specifies the IEEE 802.1Q priority used for the management VLAN. |
| 1.3.6.1.4.1.193.72.600.1.1.6.7 | ScalarvlanTagging | read-write | current | If 0, VLAN tagging is off, meaning that VLAN is not used. If 1, VLAN tagging is used, with the given ID and Prio. |
| 1.3.6.1.4.1.193.72.600.1.1.6.8 | ScalarbootString | read-only | current | Text commands for the bootloader. |
| 1.3.6.1.4.1.193.72.600.1.1.7 | NodeupgradeSW | |||
| 1.3.6.1.4.1.193.72.600.1.1.7.1 | ScalarswFileName | read-write | current | The filename to upload to the device. The path to this file is in the root directory that is specified in the FTP server |
| 1.3.6.1.4.1.193.72.600.1.1.7.2 | ScalaruploadSW | read-write | current | Upload new application software to device. The file which is loaded is indicated by the swFileName parameter. 1 - upload SW to the device and restart afterward… |
| 1.3.6.1.4.1.193.72.600.1.1.7.3 | ScalarbootSwFileName | read-write | current | The filename of a boot sw image located on the domain file server. This file name is used by the uploadBootSw. |
| 1.3.6.1.4.1.193.72.600.1.1.7.4 | ScalaruploadBootSw | read-write | current | Upload new boot software to this device. The boot sw image must be named by the bootSwFileName parameter and located on the domain file server, which is the ne… |
| 1.3.6.1.4.1.193.72.600.1.1.8 | ScalarhideInternalInterfaces | read-write | current | The management system can chose to hide all interfaces (RFC1233/RFC2233) that are irrelevant in the PEM network view (HP OpenView issue). If 0, Don't hide any … |
| 1.3.6.1.4.1.193.72.600.1.1.9 | Scalarrestart | read-write | current | When set to 'restart' the device restarts, which includes loading the SW image and configuration data from the server. In this way a new SW version can be load… |
| 1.3.6.1.4.1.193.72.600.1.1.10 | ScalarledsAltBlink | read-write | current | When the ledsAltBlink is set to ON(1) the LEDs will start to blink alternatively. |
| 1.3.6.1.4.1.193.72.600.1.1.11 | ScalarstartCfgVerification | read-write | current | When startCfgVerification is set to verify(1) the device retrieves the configuration file from a server and overwrites its parameters with the parameters from … |
| 1.3.6.1.4.1.193.72.600.1.1.12 | ScalarsaveCfgToNvm | read-write | current | When saveCfgToNvm is set to start(1) the device saves the configuration data parameters to NVM. |
| 1.3.6.1.4.1.193.72.600.1.1.13 | ScalarcfgVerificationInterval | read-write | current | This is the time in minutes between configuration file verification. If the value is zero the configuration verification is disabled. |
| 1.3.6.1.4.1.193.72.600.1.1.14 | ScalarnotifyType | read-write | current | Set the type of the notify sent by the device: 1. Trap 2. Inform |
| 1.3.6.1.4.1.193.72.600.1.1.15 | NodeidentificationData | |||
| 1.3.6.1.4.1.193.72.600.1.1.15.1 | NodedeviceIdData | |||
| 1.3.6.1.4.1.193.72.600.1.1.15.1.1 | ScalarproductNumber | read-only | current | Index number that identifies the device. |
| 1.3.6.1.4.1.193.72.600.1.1.15.1.2 | ScalarrevisionState | read-only | current | Revision State or 'R-state' declaring minor versions. E.g. different types of components or new boot SW. |
| 1.3.6.1.4.1.193.72.600.1.1.15.1.3 | ScalarfunctionDesignation | read-only | current | Number with reference to the handling and use of the product. |
| 1.3.6.1.4.1.193.72.600.1.1.15.1.4 | ScalardateOfProduction | read-only | current | Manufacturing date, describing when the unit has been manufactured, in terms of a year, month and a day, as described below: Year code(0000 ..9999) - 2 bytes (… |
| 1.3.6.1.4.1.193.72.600.1.1.15.1.5 | ScalardateOfRepair | read-only | current | Repair date, declaring the year, month and day of the latest repair. The format is described below: Year code(0000 ..9999) - 2 bytes (LSB,MSB) Month (1..12)- 1… |
| 1.3.6.1.4.1.193.72.600.1.1.15.1.6 | ScalarproductionSerialNumber | read-only | current | Unique serial number, describing the product in terms of a manufacturing site code and a sequence number. |
| 1.3.6.1.4.1.193.72.600.1.1.15.1.7 | ScalarlayoutVersionCode | read-only | current | The data layout version that allows the possibility to interpret stored data differently. |
| 1.3.6.1.4.1.193.72.600.1.1.15.1.8 | ScalaridCheckSum | read-only | current | CRC32 Checksum of identification data structure of the device. |
| 1.3.6.1.4.1.193.72.600.1.1.15.2 | NodemicroProcessorIdData | |||
| 1.3.6.1.4.1.193.72.600.1.1.15.2.1 | ScalarproductNumberMicroProcessor | read-only | current | Index number that identifies the MicroProcessor board. |
| 1.3.6.1.4.1.193.72.600.1.1.15.2.2 | ScalarrevisionStateMicroProcessor | read-only | current | Revision State or 'R-state' declaring minor versions. E.g. different types of components or new boot SW. |
| 1.3.6.1.4.1.193.72.600.1.1.15.2.3 | ScalarfunctionDesignationMicroProcessor | read-only | current | Number with reference to the handling and use of the product. |
| 1.3.6.1.4.1.193.72.600.1.1.15.2.4 | ScalardateOfProductionMicroProcessor | read-only | current | Manufacturing date, describing when the unit has been manufactured, in terms of a year, month and a day, as described below: Year code(0000 ..9999) - 2 bytes (… |
| 1.3.6.1.4.1.193.72.600.1.1.15.2.5 | ScalardateOfRepairMicroProcessor | read-only | current | Repair date, declaring the year, month and day of the latest repair. he format is described below: Year code(0000 ..9999) - 2 bytes (LSB,MSB) Month (1..12)- 1 … |
| 1.3.6.1.4.1.193.72.600.1.1.15.2.6 | ScalarproductionSerialNumberMicroProcessor | read-only | current | Unique serial number, describing the product in terms of a manufacturing site code and a sequence number. |
| 1.3.6.1.4.1.193.72.600.1.1.15.2.7 | ScalarlayoutVersionCodeMicroProcessor | read-only | current | The data layout version that allows the possibility to interpret stored data differently. |
| 1.3.6.1.4.1.193.72.600.1.1.15.2.8 | ScalaridCheckSumMicroProcessor | read-only | current | CRC32 Checksum of identification data structure for the MicroProcessor board. |
| 1.3.6.1.4.1.193.72.600.1.1.15.3 | NodeanalogueFrontEndIdData | |||
| 1.3.6.1.4.1.193.72.600.1.1.15.3.1 | ScalarproductNumberAnalogueFrontEnd | read-only | current | Index number that identifies the AFE board. |
| 1.3.6.1.4.1.193.72.600.1.1.15.3.2 | ScalarrevisionStateAnalogueFrontEnd | read-only | current | Revision State or 'R-state' declaring minor versions. E.g. different types of components or new boot SW. |
| 1.3.6.1.4.1.193.72.600.1.1.15.3.3 | ScalarfunctionDesignationAnalogueFrontEnd | read-only | current | Number with reference to the handling and use of the product. |
| 1.3.6.1.4.1.193.72.600.1.1.15.3.4 | ScalardateOfProductionAnalogueFrontEnd | read-only | current | Manufacturing date, describing when the unit has been manufactured, in terms of a year, month and a day, as described below: Year code(0000 ..9999) - 2 bytes (… |
| 1.3.6.1.4.1.193.72.600.1.1.15.3.5 | ScalardateOfRepairAnalogueFrontEnd | read-only | current | Repair date, declaring the year, month and day of the latest repair. The format is described below: Year code(0000 ..9999) - 2 bytes (LSB,MSB) Month (1..12)- 1… |
| 1.3.6.1.4.1.193.72.600.1.1.15.3.6 | ScalarproductionSerialNumberAnalogueFrontEnd | read-only | current | Unique serial number, describing the product in terms of a manufacturing site code and a sequence number. |
| 1.3.6.1.4.1.193.72.600.1.1.15.3.7 | ScalarlayoutVersionCodeAnalogueFrontEnd | read-only | current | The data layout version that allows the possibility to interpret stored data differently. |
| 1.3.6.1.4.1.193.72.600.1.1.15.3.8 | ScalaridCheckSumAnalogueFrontEnd | read-only | current | CRC32 Checksum of identification data structure for the Analogue Front End board. |
| 1.3.6.1.4.1.193.72.600.1.1.15.4 | NodedcDcConverterIdData | |||
| 1.3.6.1.4.1.193.72.600.1.1.15.4.1 | ScalarproductNumberDcDcConverter | read-only | current | Index number that identifies the DC-DC Converter board. |
| 1.3.6.1.4.1.193.72.600.1.1.15.4.2 | ScalarrevisionStateDcDcConverter | read-only | current | Revision State or 'R-state' declaring minor versions. E.g. different types of components or new boot SW. |
| 1.3.6.1.4.1.193.72.600.1.1.15.4.3 | ScalarfunctionDesignationDcDcConverter | read-only | current | Number with reference to the handling and use of the product. |
| 1.3.6.1.4.1.193.72.600.1.1.15.4.4 | ScalardateOfProductionDcDcConverter | read-only | current | Manufacturing date, describing when the unit has been manufactured, in terms of a year, month and a day, as described below: Year code(0000 ..9999) - 2 bytes (… |
| 1.3.6.1.4.1.193.72.600.1.1.15.4.5 | ScalardateOfRepairDcDcConverter | read-only | current | Repair date, declaring the year, month and day of the latest repair. The format is described below: Year code(0000 ..9999) - 2 bytes (LSB,MSB) Month (1..12)- 1… |
| 1.3.6.1.4.1.193.72.600.1.1.15.4.6 | ScalarproductionSerialNumberDcDcConverter | read-only | current | Unique serial number, describing the product in terms of a manufacturing site code and a sequence number. |
| 1.3.6.1.4.1.193.72.600.1.1.15.4.7 | ScalarlayoutVersionCodeDcDcConverter | read-only | current | The data layout version that allows the possibility to interpret stored data differently. |
| 1.3.6.1.4.1.193.72.600.1.1.15.4.8 | ScalaridCheckSumDcDcConverter | read-only | current | CRC32 Checksum of identification data for the DC-DC Converter board. |
| 1.3.6.1.4.1.193.72.600.1.1.16 | ScalarsntpServerIP | read-write | current | The IP address of SNTP server used for time synchronization. |
| 1.3.6.1.4.1.193.72.600.1.2 | NodecommonTraps | |||
| 1.3.6.1.4.1.193.72.600.1.2.0 | Nodetraps | |||
| 1.3.6.1.4.1.193.72.600.1.2.0.1 | NotificationtempTooHigh | current | Temperature is too high. The temperature has increased above a fixed threshold value. The high temperature value is probably caused by fan failure or high envi… | |
| 1.3.6.1.4.1.193.72.600.1.2.0.2 | NotificationtempTooHighCeasing | current | Temperature too high ceasing. The temperature has decreased below a fixed threshold value in the normal working area. For the IP DSLAM the lines are brought in… | |
| 1.3.6.1.4.1.193.72.600.1.2.0.3 | NotificationgreenFanFailure | current | Indicates a fan failure on the fan closest to the green LED. For ESN310, green fan is the fan place to the front | |
| 1.3.6.1.4.1.193.72.600.1.2.0.4 | NotificationgreenFanCeasing | current | Indicates the ceasing of the fan which is closest to the green LED. For ESN310, green fan is the fan place to the front | |
| 1.3.6.1.4.1.193.72.600.1.2.0.5 | NotificationredFanFailure | current | Indicates a fan failure on the fan closest to the red LED. For ESN310, red fan is the fan place to the back | |
| 1.3.6.1.4.1.193.72.600.1.2.0.6 | NotificationredFanCeasing | current | Indicates the ceasing of the fan which is closest to the red LED. For ESN310, red fan is the fan place to the back | |
| 1.3.6.1.4.1.193.72.600.1.2.0.7 | NotificationrestartAlarm | current | Device restart alarm. The post mortem information will indicate the reason for the restart. | |
| 1.3.6.1.4.1.193.72.600.1.2.0.8 | NotificationstateEventErr | current | State/Event SW error detected. Called by the Default Error Handler in DMAPI when a message is discarded. | |
| 1.3.6.1.4.1.193.72.600.1.2.0.9 | NotificationnonFatalSoftwareErr | current | Non-fatal SW error detected. | |
| 1.3.6.1.4.1.193.72.600.1.2.0.10 | NotificationfatalSoftwareErr | current | Fatal SW error detected - The device SW will restart. | |
| 1.3.6.1.4.1.193.72.600.1.2.0.11 | NotificationconfigurationFileErr | current | Configuration file load or pass error. | |
| 1.3.6.1.4.1.193.72.600.1.2.0.12 | NotificationidDataReadErr | current | Indicates that the identification data read from FLASH for the HW unit indicated by 'hwUnitId' parameter is corrupted. | |
| 1.3.6.1.4.1.193.72.600.1.2.0.13 | NotificationcfgDataReadErr | current | Indicates that the configuration data read from FLASH for the device is corrupted. The 'configData' parameter indicates the data corrupted. | |
| 1.3.6.1.4.1.193.72.600.1.2.0.14 | NotificationwriteFlashErr | current | Indicates that an error occured during FLASH writing. | |
| 1.3.6.1.4.1.193.72.600.1.2.0.15 | NotificationbothFansFailed | current | Indicates that both fans failed. | |
| 1.3.6.1.4.1.193.72.600.1.2.0.16 | NotificationbothFansFailCeasing | current | Indicates the ceasing of both fans failure. At least one of the fans is working. | |
| 1.3.6.1.4.1.193.72.600.1.2.0.17 | NotificationdeviceTypeUnknown | current | Indicates that the device type can not be identified. The product number and revision state are unkonwn or corrupted. The application software can not handle h… | |
| 1.3.6.1.4.1.193.72.600.1.2.0.18 | NotificationgreenFanLowPerformance | current | Indicates that the fan, which is close to the green LED, has a low performance. | |
| 1.3.6.1.4.1.193.72.600.1.2.0.19 | NotificationgreenFanLowPerformanceCeasing | current | Indicates the ceasing of the low performance of the fan, which is close to the green LED. | |
| 1.3.6.1.4.1.193.72.600.1.2.0.20 | NotificationredFanLowPerformance | current | Indicates that the fan, which is close to the red LED, has a low performance. | |
| 1.3.6.1.4.1.193.72.600.1.2.0.21 | NotificationredFanLowPerformanceCeasing | current | Indicates the ceasing of the low performace of the fan, which is close to the red LED. | |
| 1.3.6.1.4.1.193.72.600.1.2.0.22 | NotificationtempCloseToTooHigh | current | Indicates the temperature is close to the too high value, when the subscriber lines are shut down. | |
| 1.3.6.1.4.1.193.72.600.1.2.0.23 | NotificationtempCloseToTooHighCeasing | current | Indicates that the temperatureCloseToTooHigh alarm is ceased. | |
| 1.3.6.1.4.1.193.72.600.1.2.0.24 | NotificationconfigurationMismatch | current | This alarm has a higher severity than configurationItemMismatch and is only sent once no matter how many parameter mismatches that is detected. This can be con… | |
| 1.3.6.1.4.1.193.72.600.1.2.0.25 | NotificationconfigurationItemMismatch | current | This alarm is sent for each parameter where a mismatch is detected. If e.g. the trap notification is set to 'inform' and that it was expected to be 'trap' then… | |
| 1.3.6.1.4.1.193.72.600.1.2.0.26 | NotificationswUploadErr | current | An error occured during software upload. | |
| 1.3.6.1.4.1.193.72.600.1.2.0.27 | NotificationprogramStartFailure | current | When no valid flash part can be found on the device this trap is sent. | |
| 1.3.6.1.4.1.193.72.600.1.2.1 | NodetrapsParameters | |||
| 1.3.6.1.4.1.193.72.600.1.2.1.1 | ScalartaskId | accessible-for-notify | current | The name of the task, which sent the alarm. |
| 1.3.6.1.4.1.193.72.600.1.2.1.2 | ScalartaskState | accessible-for-notify | current | The state of the task, which sent the alarm. |
| 1.3.6.1.4.1.193.72.600.1.2.1.3 | ScalartaskFileName | accessible-for-notify | current | The file name from where the alarm was sent |
| 1.3.6.1.4.1.193.72.600.1.2.1.4 | ScalarlineNumber | accessible-for-notify | current | The line number in the file indicated by taskFileName, from where the alarm was sent |
| 1.3.6.1.4.1.193.72.600.1.2.1.5 | ScalarmsgSenderTask | accessible-for-notify | current | Indicates the name of the task which sent the message causing a stateEventError. |
| 1.3.6.1.4.1.193.72.600.1.2.1.6 | ScalarerrCode | accessible-for-notify | current | Additional error information. |
| 1.3.6.1.4.1.193.72.600.1.2.1.7 | ScalarpostMortemInfo | accessible-for-notify | current | Indicates the reason of the restart. |
| 1.3.6.1.4.1.193.72.600.1.2.1.8 | ScalarerrData | accessible-for-notify | current | Additional data related to the error. |
| 1.3.6.1.4.1.193.72.600.1.2.1.9 | ScalarmsgId | accessible-for-notify | current | Message ID of the last received message. E.g. the ID of the message causing a state event error. |
| 1.3.6.1.4.1.193.72.600.1.2.1.10 | ScalarmsgData | accessible-for-notify | current | Message content of the last received message. E.g. the content of the message causing a state event error. |
| 1.3.6.1.4.1.193.72.600.1.2.1.11 | ScalarhwUnitId | accessible-for-notify | current | Identifies the HW unit which has the identification data corrupted into FLASH. |
| 1.3.6.1.4.1.193.72.600.1.2.1.12 | ScalarconfigData | accessible-for-notify | current | Identifies the corrupted configuration data read from FLASH . |
| 1.3.6.1.4.1.193.72.600.1.2.1.13 | ScalaridOrConfigData | accessible-for-notify | current | Identifies during which data writing occured an error. |
| 1.3.6.1.4.1.193.72.600.1.3 | NodepethObjects | |||
| 1.3.6.1.4.1.193.72.600.1.4 | NodepethNotifications | |||
| 1.3.6.1.4.1.193.72.600.1.4.0 | NodepethNotificationTypes | |||
| 1.3.6.1.4.1.193.72.600.1.4.0.1 | NotificationpethPsePortFailureNotification | current | This notification is sent when the port detects a permanent power failure. It is not specified if the notification is triggered by a malfunction on the PSE, PD… | |
| 1.3.6.1.4.1.193.72.600.1.4.0.2 | NotificationpethPsePortFailureCeasingNotification | current | The CEASING counterpart of pethPsePortFailureNotification. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| PhyModeType | OCTET STRING (SIZE (1)) | current | Represent the Ethernet PHY Mode. |