MIB Viewer

PEA_EQUIPMENT

136 objects
The public ethernet access software supports a number of standard and proprietary MIBs. This MIB module defines objects for reading/writing common equipment information.
OIDNameAccessStatusDescription
1.3.6.1.4.1.193.72.600.1IdentitypeaEquipmentThe public ethernet access software supports a number of standard and proprietary MIBs. This MIB module defines objects for reading/writing common equipment in…
1.3.6.1.4.1.193.72.600.1.1NodecommonObjects
1.3.6.1.4.1.193.72.600.1.1.1Nodeversions
1.3.6.1.4.1.193.72.600.1.1.1.1ScalarsysIdread-onlycurrentThis value includes the full name and version identification of the device software.
1.3.6.1.4.1.193.72.600.1.1.1.2ScalarbootSwIdread-onlycurrentThis value includes the full name and version identification of the BOOT software.
1.3.6.1.4.1.193.72.600.1.1.1.3ScalarcfgVerread-writecurrentThe CfgVer will initially be zero, but is set to the version number defined in the configuration file received from the tftp server at system start-up. The man…
1.3.6.1.4.1.193.72.600.1.1.1.4ScalaractiveSwInforead-onlycurrentThis value represents the software version of the active software part of the device.
1.3.6.1.4.1.193.72.600.1.1.1.5ScalarpassiveSwInforead-onlycurrentThis value represents the software version of the passive software part of the device.
1.3.6.1.4.1.193.72.600.1.1.2NodemainProcessor
1.3.6.1.4.1.193.72.600.1.1.2.1ScalarprocessorLoadread-onlycurrentThe percentage of time that the main processor was not idle. Average over 10 seconds. (almost like hrProcessorLoad in RFC1514).
1.3.6.1.4.1.193.72.600.1.1.2.2ScalarmemFreeread-onlycurrentThe amount of free memory on main processor in percent.
1.3.6.1.4.1.193.72.600.1.1.2.3ScalarmemFreeBytesread-onlycurrentThe amount of free memory on main processor in bytes.
1.3.6.1.4.1.193.72.600.1.1.2.4ScalarmemBuffersUsedread-onlycurrentThe total number of memory buffers currently used (Ethernet, ATM & local IP-stack).
1.3.6.1.4.1.193.72.600.1.1.3Nodetemperature
1.3.6.1.4.1.193.72.600.1.1.3.1ScalartempControlStateread-onlycurrentThe state of the temperature control can be: 0 - Low 1 - Normal 2 - High 3 - TooHigh
1.3.6.1.4.1.193.72.600.1.1.3.2ScalartempValueread-onlycurrentThe temperature value in the device in grade Celsius.
1.3.6.1.4.1.193.72.600.1.1.4NodefansStatus
1.3.6.1.4.1.193.72.600.1.1.4.1ScalargreenFanStatusread-onlycurrentThe status of the fan which is placed closest to the green LED. For ESN310, green fan is the fan place to the front
1.3.6.1.4.1.193.72.600.1.1.4.2ScalarredFanStatusread-onlycurrentThe status of the fan which is placed closest to the red LED. For ESN310, red fan is the fan place to the back
1.3.6.1.4.1.193.72.600.1.1.4.3ScalargreenFanSpeedread-onlycurrentThe speed of the fan, which is placed closest to the green LED, measured in rpm (rotations per minute).
1.3.6.1.4.1.193.72.600.1.1.4.4ScalarredFanSpeedread-onlycurrentThe speed of the fan, which is placed closest to the red LED, measured in rpm (rotations per minute).
1.3.6.1.4.1.193.72.600.1.1.5NodealarmFilter
1.3.6.1.4.1.193.72.600.1.1.5.1ScalarcomAlarmFilterread-writecurrentThis alarm filter will filter out all communication alarms with lower severity than the selected. E.g. Selecting minor (1) would filter out all alarms with war…
1.3.6.1.4.1.193.72.600.1.1.5.2ScalarenvAlarmFilterread-writecurrentThis alarm filter will filter out all environment alarms with lower severity than the selected. E.g. Selecting minor (1) would filter out all alarms with warni…
1.3.6.1.4.1.193.72.600.1.1.5.3ScalarequipAlarmFilterread-writecurrentThis alarm filter will filter out all equipment alarms with lower severity than the selected. E.g. Selecting minor (1) would filter out all alarms with warning…
1.3.6.1.4.1.193.72.600.1.1.5.4ScalarprocessAlarmFilterread-writecurrentThis alarm filter will filter out all processing alarms with lower severity than the selected. E.g. Selecting minor (1) would filter out all alarms with warnin…
1.3.6.1.4.1.193.72.600.1.1.5.5ScalarqosAlarmFilterread-writecurrentThis alarm filter will filter out all quality alarms with lower severity than the selected. E.g. Selecting minor (1) would filter out all alarms with warning (…
1.3.6.1.4.1.193.72.600.1.1.5.6ScalaralarmFilterThresread-writecurrentThe threshold value indicates how many alarms that can be filtered by the device in the time interval indicated by the alarmFilterInterval parameter before an …
1.3.6.1.4.1.193.72.600.1.1.5.7ScalaralarmFilterIntervalread-writecurrentThe value of this parameter indicates the time interval in which the device can filter a number of alarms indicated by the alarmFilterThres parameter before an…
1.3.6.1.4.1.193.72.600.1.1.6NodeconfigurationData
1.3.6.1.4.1.193.72.600.1.1.6.1ScalarlocalMacAddrread-onlycurrentUnique MAC address of the device.
1.3.6.1.4.1.193.72.600.1.1.6.2ScalarphyModeread-writecurrentEthernet PHY Mode setting. The Phy Mode is coded as a bitfield: � Bit 0: Auto-negotiation. If set, auto-negotiation is OFF else ON. � Bit 2: Full Duplex co…
1.3.6.1.4.1.193.72.600.1.1.6.3ScalarwatchDogEnableread-onlycurrentEnabling of the HW Watchdog. If 0 (zero), the watchdog is OFF, else the watchdog is ON.
1.3.6.1.4.1.193.72.600.1.1.6.5ScalarvlanIdread-writecurrentThe VLAN ID setting for the management VLAN.
1.3.6.1.4.1.193.72.600.1.1.6.6ScalarvlanPrioread-writecurrentSpecifies the IEEE 802.1Q priority used for the management VLAN.
1.3.6.1.4.1.193.72.600.1.1.6.7ScalarvlanTaggingread-writecurrentIf 0, VLAN tagging is off, meaning that VLAN is not used. If 1, VLAN tagging is used, with the given ID and Prio.
1.3.6.1.4.1.193.72.600.1.1.6.8ScalarbootStringread-onlycurrentText commands for the bootloader.
1.3.6.1.4.1.193.72.600.1.1.7NodeupgradeSW
1.3.6.1.4.1.193.72.600.1.1.7.1ScalarswFileNameread-writecurrentThe filename to upload to the device. The path to this file is in the root directory that is specified in the FTP server
1.3.6.1.4.1.193.72.600.1.1.7.2ScalaruploadSWread-writecurrentUpload new application software to device. The file which is loaded is indicated by the swFileName parameter. 1 - upload SW to the device and restart afterward…
1.3.6.1.4.1.193.72.600.1.1.7.3ScalarbootSwFileNameread-writecurrentThe filename of a boot sw image located on the domain file server. This file name is used by the uploadBootSw.
1.3.6.1.4.1.193.72.600.1.1.7.4ScalaruploadBootSwread-writecurrentUpload new boot software to this device. The boot sw image must be named by the bootSwFileName parameter and located on the domain file server, which is the ne…
1.3.6.1.4.1.193.72.600.1.1.8ScalarhideInternalInterfacesread-writecurrentThe management system can chose to hide all interfaces (RFC1233/RFC2233) that are irrelevant in the PEM network view (HP OpenView issue). If 0, Don't hide any …
1.3.6.1.4.1.193.72.600.1.1.9Scalarrestartread-writecurrentWhen set to 'restart' the device restarts, which includes loading the SW image and configuration data from the server. In this way a new SW version can be load…
1.3.6.1.4.1.193.72.600.1.1.10ScalarledsAltBlinkread-writecurrentWhen the ledsAltBlink is set to ON(1) the LEDs will start to blink alternatively.
1.3.6.1.4.1.193.72.600.1.1.11ScalarstartCfgVerificationread-writecurrentWhen startCfgVerification is set to verify(1) the device retrieves the configuration file from a server and overwrites its parameters with the parameters from …
1.3.6.1.4.1.193.72.600.1.1.12ScalarsaveCfgToNvmread-writecurrentWhen saveCfgToNvm is set to start(1) the device saves the configuration data parameters to NVM.
1.3.6.1.4.1.193.72.600.1.1.13ScalarcfgVerificationIntervalread-writecurrentThis is the time in minutes between configuration file verification. If the value is zero the configuration verification is disabled.
1.3.6.1.4.1.193.72.600.1.1.14ScalarnotifyTyperead-writecurrentSet the type of the notify sent by the device: 1. Trap 2. Inform
1.3.6.1.4.1.193.72.600.1.1.15NodeidentificationData
1.3.6.1.4.1.193.72.600.1.1.15.1NodedeviceIdData
1.3.6.1.4.1.193.72.600.1.1.15.1.1ScalarproductNumberread-onlycurrentIndex number that identifies the device.
1.3.6.1.4.1.193.72.600.1.1.15.1.2ScalarrevisionStateread-onlycurrentRevision State or 'R-state' declaring minor versions. E.g. different types of components or new boot SW.
1.3.6.1.4.1.193.72.600.1.1.15.1.3ScalarfunctionDesignationread-onlycurrentNumber with reference to the handling and use of the product.
1.3.6.1.4.1.193.72.600.1.1.15.1.4ScalardateOfProductionread-onlycurrentManufacturing date, describing when the unit has been manufactured, in terms of a year, month and a day, as described below: Year code(0000 ..9999) - 2 bytes (…
1.3.6.1.4.1.193.72.600.1.1.15.1.5ScalardateOfRepairread-onlycurrentRepair date, declaring the year, month and day of the latest repair. The format is described below: Year code(0000 ..9999) - 2 bytes (LSB,MSB) Month (1..12)- 1…
1.3.6.1.4.1.193.72.600.1.1.15.1.6ScalarproductionSerialNumberread-onlycurrentUnique serial number, describing the product in terms of a manufacturing site code and a sequence number.
1.3.6.1.4.1.193.72.600.1.1.15.1.7ScalarlayoutVersionCoderead-onlycurrentThe data layout version that allows the possibility to interpret stored data differently.
1.3.6.1.4.1.193.72.600.1.1.15.1.8ScalaridCheckSumread-onlycurrentCRC32 Checksum of identification data structure of the device.
1.3.6.1.4.1.193.72.600.1.1.15.2NodemicroProcessorIdData
1.3.6.1.4.1.193.72.600.1.1.15.2.1ScalarproductNumberMicroProcessorread-onlycurrentIndex number that identifies the MicroProcessor board.
1.3.6.1.4.1.193.72.600.1.1.15.2.2ScalarrevisionStateMicroProcessorread-onlycurrentRevision State or 'R-state' declaring minor versions. E.g. different types of components or new boot SW.
1.3.6.1.4.1.193.72.600.1.1.15.2.3ScalarfunctionDesignationMicroProcessorread-onlycurrentNumber with reference to the handling and use of the product.
1.3.6.1.4.1.193.72.600.1.1.15.2.4ScalardateOfProductionMicroProcessorread-onlycurrentManufacturing date, describing when the unit has been manufactured, in terms of a year, month and a day, as described below: Year code(0000 ..9999) - 2 bytes (…
1.3.6.1.4.1.193.72.600.1.1.15.2.5ScalardateOfRepairMicroProcessorread-onlycurrentRepair date, declaring the year, month and day of the latest repair. he format is described below: Year code(0000 ..9999) - 2 bytes (LSB,MSB) Month (1..12)- 1 …
1.3.6.1.4.1.193.72.600.1.1.15.2.6ScalarproductionSerialNumberMicroProcessorread-onlycurrentUnique serial number, describing the product in terms of a manufacturing site code and a sequence number.
1.3.6.1.4.1.193.72.600.1.1.15.2.7ScalarlayoutVersionCodeMicroProcessorread-onlycurrentThe data layout version that allows the possibility to interpret stored data differently.
1.3.6.1.4.1.193.72.600.1.1.15.2.8ScalaridCheckSumMicroProcessorread-onlycurrentCRC32 Checksum of identification data structure for the MicroProcessor board.
1.3.6.1.4.1.193.72.600.1.1.15.3NodeanalogueFrontEndIdData
1.3.6.1.4.1.193.72.600.1.1.15.3.1ScalarproductNumberAnalogueFrontEndread-onlycurrentIndex number that identifies the AFE board.
1.3.6.1.4.1.193.72.600.1.1.15.3.2ScalarrevisionStateAnalogueFrontEndread-onlycurrentRevision State or 'R-state' declaring minor versions. E.g. different types of components or new boot SW.
1.3.6.1.4.1.193.72.600.1.1.15.3.3ScalarfunctionDesignationAnalogueFrontEndread-onlycurrentNumber with reference to the handling and use of the product.
1.3.6.1.4.1.193.72.600.1.1.15.3.4ScalardateOfProductionAnalogueFrontEndread-onlycurrentManufacturing date, describing when the unit has been manufactured, in terms of a year, month and a day, as described below: Year code(0000 ..9999) - 2 bytes (…
1.3.6.1.4.1.193.72.600.1.1.15.3.5ScalardateOfRepairAnalogueFrontEndread-onlycurrentRepair date, declaring the year, month and day of the latest repair. The format is described below: Year code(0000 ..9999) - 2 bytes (LSB,MSB) Month (1..12)- 1…
1.3.6.1.4.1.193.72.600.1.1.15.3.6ScalarproductionSerialNumberAnalogueFrontEndread-onlycurrentUnique serial number, describing the product in terms of a manufacturing site code and a sequence number.
1.3.6.1.4.1.193.72.600.1.1.15.3.7ScalarlayoutVersionCodeAnalogueFrontEndread-onlycurrentThe data layout version that allows the possibility to interpret stored data differently.
1.3.6.1.4.1.193.72.600.1.1.15.3.8ScalaridCheckSumAnalogueFrontEndread-onlycurrentCRC32 Checksum of identification data structure for the Analogue Front End board.
1.3.6.1.4.1.193.72.600.1.1.15.4NodedcDcConverterIdData
1.3.6.1.4.1.193.72.600.1.1.15.4.1ScalarproductNumberDcDcConverterread-onlycurrentIndex number that identifies the DC-DC Converter board.
1.3.6.1.4.1.193.72.600.1.1.15.4.2ScalarrevisionStateDcDcConverterread-onlycurrentRevision State or 'R-state' declaring minor versions. E.g. different types of components or new boot SW.
1.3.6.1.4.1.193.72.600.1.1.15.4.3ScalarfunctionDesignationDcDcConverterread-onlycurrentNumber with reference to the handling and use of the product.
1.3.6.1.4.1.193.72.600.1.1.15.4.4ScalardateOfProductionDcDcConverterread-onlycurrentManufacturing date, describing when the unit has been manufactured, in terms of a year, month and a day, as described below: Year code(0000 ..9999) - 2 bytes (…
1.3.6.1.4.1.193.72.600.1.1.15.4.5ScalardateOfRepairDcDcConverterread-onlycurrentRepair date, declaring the year, month and day of the latest repair. The format is described below: Year code(0000 ..9999) - 2 bytes (LSB,MSB) Month (1..12)- 1…
1.3.6.1.4.1.193.72.600.1.1.15.4.6ScalarproductionSerialNumberDcDcConverterread-onlycurrentUnique serial number, describing the product in terms of a manufacturing site code and a sequence number.
1.3.6.1.4.1.193.72.600.1.1.15.4.7ScalarlayoutVersionCodeDcDcConverterread-onlycurrentThe data layout version that allows the possibility to interpret stored data differently.
1.3.6.1.4.1.193.72.600.1.1.15.4.8ScalaridCheckSumDcDcConverterread-onlycurrentCRC32 Checksum of identification data for the DC-DC Converter board.
1.3.6.1.4.1.193.72.600.1.1.16ScalarsntpServerIPread-writecurrentThe IP address of SNTP server used for time synchronization.
1.3.6.1.4.1.193.72.600.1.2NodecommonTraps
1.3.6.1.4.1.193.72.600.1.2.0Nodetraps
1.3.6.1.4.1.193.72.600.1.2.0.1NotificationtempTooHighcurrentTemperature is too high. The temperature has increased above a fixed threshold value. The high temperature value is probably caused by fan failure or high envi…
1.3.6.1.4.1.193.72.600.1.2.0.2NotificationtempTooHighCeasingcurrentTemperature too high ceasing. The temperature has decreased below a fixed threshold value in the normal working area. For the IP DSLAM the lines are brought in…
1.3.6.1.4.1.193.72.600.1.2.0.3NotificationgreenFanFailurecurrentIndicates a fan failure on the fan closest to the green LED. For ESN310, green fan is the fan place to the front
1.3.6.1.4.1.193.72.600.1.2.0.4NotificationgreenFanCeasingcurrentIndicates the ceasing of the fan which is closest to the green LED. For ESN310, green fan is the fan place to the front
1.3.6.1.4.1.193.72.600.1.2.0.5NotificationredFanFailurecurrentIndicates a fan failure on the fan closest to the red LED. For ESN310, red fan is the fan place to the back
1.3.6.1.4.1.193.72.600.1.2.0.6NotificationredFanCeasingcurrentIndicates the ceasing of the fan which is closest to the red LED. For ESN310, red fan is the fan place to the back
1.3.6.1.4.1.193.72.600.1.2.0.7NotificationrestartAlarmcurrentDevice restart alarm. The post mortem information will indicate the reason for the restart.
1.3.6.1.4.1.193.72.600.1.2.0.8NotificationstateEventErrcurrentState/Event SW error detected. Called by the Default Error Handler in DMAPI when a message is discarded.
1.3.6.1.4.1.193.72.600.1.2.0.9NotificationnonFatalSoftwareErrcurrentNon-fatal SW error detected.
1.3.6.1.4.1.193.72.600.1.2.0.10NotificationfatalSoftwareErrcurrentFatal SW error detected - The device SW will restart.
1.3.6.1.4.1.193.72.600.1.2.0.11NotificationconfigurationFileErrcurrentConfiguration file load or pass error.
1.3.6.1.4.1.193.72.600.1.2.0.12NotificationidDataReadErrcurrentIndicates that the identification data read from FLASH for the HW unit indicated by 'hwUnitId' parameter is corrupted.
1.3.6.1.4.1.193.72.600.1.2.0.13NotificationcfgDataReadErrcurrentIndicates that the configuration data read from FLASH for the device is corrupted. The 'configData' parameter indicates the data corrupted.
1.3.6.1.4.1.193.72.600.1.2.0.14NotificationwriteFlashErrcurrentIndicates that an error occured during FLASH writing.
1.3.6.1.4.1.193.72.600.1.2.0.15NotificationbothFansFailedcurrentIndicates that both fans failed.
1.3.6.1.4.1.193.72.600.1.2.0.16NotificationbothFansFailCeasingcurrentIndicates the ceasing of both fans failure. At least one of the fans is working.
1.3.6.1.4.1.193.72.600.1.2.0.17NotificationdeviceTypeUnknowncurrentIndicates that the device type can not be identified. The product number and revision state are unkonwn or corrupted. The application software can not handle h…
1.3.6.1.4.1.193.72.600.1.2.0.18NotificationgreenFanLowPerformancecurrentIndicates that the fan, which is close to the green LED, has a low performance.
1.3.6.1.4.1.193.72.600.1.2.0.19NotificationgreenFanLowPerformanceCeasingcurrentIndicates the ceasing of the low performance of the fan, which is close to the green LED.
1.3.6.1.4.1.193.72.600.1.2.0.20NotificationredFanLowPerformancecurrentIndicates that the fan, which is close to the red LED, has a low performance.
1.3.6.1.4.1.193.72.600.1.2.0.21NotificationredFanLowPerformanceCeasingcurrentIndicates the ceasing of the low performace of the fan, which is close to the red LED.
1.3.6.1.4.1.193.72.600.1.2.0.22NotificationtempCloseToTooHighcurrentIndicates the temperature is close to the too high value, when the subscriber lines are shut down.
1.3.6.1.4.1.193.72.600.1.2.0.23NotificationtempCloseToTooHighCeasingcurrentIndicates that the temperatureCloseToTooHigh alarm is ceased.
1.3.6.1.4.1.193.72.600.1.2.0.24NotificationconfigurationMismatchcurrentThis alarm has a higher severity than configurationItemMismatch and is only sent once no matter how many parameter mismatches that is detected. This can be con…
1.3.6.1.4.1.193.72.600.1.2.0.25NotificationconfigurationItemMismatchcurrentThis alarm is sent for each parameter where a mismatch is detected. If e.g. the trap notification is set to 'inform' and that it was expected to be 'trap' then…
1.3.6.1.4.1.193.72.600.1.2.0.26NotificationswUploadErrcurrentAn error occured during software upload.
1.3.6.1.4.1.193.72.600.1.2.0.27NotificationprogramStartFailurecurrentWhen no valid flash part can be found on the device this trap is sent.
1.3.6.1.4.1.193.72.600.1.2.1NodetrapsParameters
1.3.6.1.4.1.193.72.600.1.2.1.1ScalartaskIdaccessible-for-notifycurrentThe name of the task, which sent the alarm.
1.3.6.1.4.1.193.72.600.1.2.1.2ScalartaskStateaccessible-for-notifycurrentThe state of the task, which sent the alarm.
1.3.6.1.4.1.193.72.600.1.2.1.3ScalartaskFileNameaccessible-for-notifycurrentThe file name from where the alarm was sent
1.3.6.1.4.1.193.72.600.1.2.1.4ScalarlineNumberaccessible-for-notifycurrentThe line number in the file indicated by taskFileName, from where the alarm was sent
1.3.6.1.4.1.193.72.600.1.2.1.5ScalarmsgSenderTaskaccessible-for-notifycurrentIndicates the name of the task which sent the message causing a stateEventError.
1.3.6.1.4.1.193.72.600.1.2.1.6ScalarerrCodeaccessible-for-notifycurrentAdditional error information.
1.3.6.1.4.1.193.72.600.1.2.1.7ScalarpostMortemInfoaccessible-for-notifycurrentIndicates the reason of the restart.
1.3.6.1.4.1.193.72.600.1.2.1.8ScalarerrDataaccessible-for-notifycurrentAdditional data related to the error.
1.3.6.1.4.1.193.72.600.1.2.1.9ScalarmsgIdaccessible-for-notifycurrentMessage ID of the last received message. E.g. the ID of the message causing a state event error.
1.3.6.1.4.1.193.72.600.1.2.1.10ScalarmsgDataaccessible-for-notifycurrentMessage content of the last received message. E.g. the content of the message causing a state event error.
1.3.6.1.4.1.193.72.600.1.2.1.11ScalarhwUnitIdaccessible-for-notifycurrentIdentifies the HW unit which has the identification data corrupted into FLASH.
1.3.6.1.4.1.193.72.600.1.2.1.12ScalarconfigDataaccessible-for-notifycurrentIdentifies the corrupted configuration data read from FLASH .
1.3.6.1.4.1.193.72.600.1.2.1.13ScalaridOrConfigDataaccessible-for-notifycurrentIdentifies during which data writing occured an error.
1.3.6.1.4.1.193.72.600.1.3NodepethObjects
1.3.6.1.4.1.193.72.600.1.4NodepethNotifications
1.3.6.1.4.1.193.72.600.1.4.0NodepethNotificationTypes
1.3.6.1.4.1.193.72.600.1.4.0.1NotificationpethPsePortFailureNotificationcurrentThis notification is sent when the port detects a permanent power failure. It is not specified if the notification is triggered by a malfunction on the PSE, PD…
1.3.6.1.4.1.193.72.600.1.4.0.2NotificationpethPsePortFailureCeasingNotificationcurrentThe CEASING counterpart of pethPsePortFailureNotification.
Type Definitions
NameSyntaxStatusDescription
PhyModeTypeOCTET STRING (SIZE (1))currentRepresent the Ethernet PHY Mode.