PETH-MIB
52 objects
The MIB module for for managing Powered Devices (PD) or Power Source Equipment (PSE) working according to the IEEE 802.af Powere Ethernet (DTE Power via MDI) standard.
Imported Objects
| EtherLike-MIB | dot3 |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | Gauge32 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
| SNMPv2-TC | TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.2.1.10.7.20 | IdentitypowerEthernetMIB | The MIB module for for managing Powered Devices (PD) or Power Source Equipment (PSE) working according to the IEEE 802.af Powere Ethernet (DTE Power via MDI) s… | ||
| 1.3.6.1.2.1.10.7.20.1 | NodepethObjects | |||
| 1.3.6.1.2.1.10.7.20.1.1 | TablepethPsePortTable | not-accessible | current | A table of objects that display and control the power characteristics power Ethernet ports on a Power Source Entity (PSE) device. This group will be implemente… |
| 1.3.6.1.2.1.10.7.20.1.1.1 | RowpethPsePortEntry | not-accessible | current | A set of objects that display and control the power characteristics of a power Ethernet PSE port. |
| 1.3.6.1.2.1.10.7.20.1.1.1.1 | ColumnpethPsePortGroupIndex | not-accessible | current | This variable uniquely identifies the group containing the port to which power Ethernet PSE is connected. Group means a box in the stack, or a module in a rack… |
| 1.3.6.1.2.1.10.7.20.1.1.1.2 | ColumnpethPsePortIndex | not-accessible | current | This variable uniquely identifies the power Ethernet PSE port within group pethPseGroupIndex to which the power Ethernet PSE entry is connected. |
| 1.3.6.1.2.1.10.7.20.1.1.1.3 | ColumnpethPsePortPowerEnable | read-write | current | Enables power supply on this port. Setting this object at a value auto(1) enables power and detection mechanism for this port. Setting this object at a value o… |
| 1.3.6.1.2.1.10.7.20.1.1.1.4 | ColumnpethPsePortPowerIdPairsControl | read-only | current | Describes the capability of controlling the power pairs functionality to switch pins for sourcing power. |
| 1.3.6.1.2.1.10.7.20.1.1.1.5 | ColumnpethPsePortPowerIdPairs | read-write | current | Describes or controls the pairs in use. If the value of pethPsePortPowerIdpairsControl is true, thisobject is writable. A value of signal(1) menas that the sig… |
| 1.3.6.1.2.1.10.7.20.1.1.1.6 | ColumnpethPsePortPowerDetectionStatus | read-write | current | Controls the power detection mechanism of the port. Setting the value auto(1) enables the power detection mechanism of the port. Setting the value off(2) disab… |
| 1.3.6.1.2.1.10.7.20.1.1.1.7 | ColumnpethPsePortDetectionOperStatus | read-only | current | Describes the operational status of the port detection. A value of deliveringPower(1) indicates that the port executed the detection algorithm, found a PD conn… |
| 1.3.6.1.2.1.10.7.20.1.1.1.8 | ColumnpethPsePortPowerPriority | read-write | current | This object controls the priority of the port from the point of view of a power management algorithm. The priority that is set by this variable could be used b… |
| 1.3.6.1.2.1.10.7.20.1.1.1.9 | ColumnpethPsePortDenyError | read-only | current | This object describes an error resulted from an action of the power management mechanism. The value lowPriority(2) indicates that the port was disabled by the … |
| 1.3.6.1.2.1.10.7.20.1.1.1.10 | ColumnpethPsePortStatus | read-only | current | Describes a current port status related to the power generation The value underCurrent(2) indicates that the port current is below the minimal value. The value… |
| 1.3.6.1.2.1.10.7.20.1.1.1.11 | ColumnpethPsePortStatusClear | read-write | current | Setting the value of this object to clear(1) clears the value of the pethPsePortStatus to none(1). |
| 1.3.6.1.2.1.10.7.20.1.1.1.12 | ColumnpethPsePortType | read-write | current | A manager will set the value of this variable to a value that indicates the type of the device that is connected to theport. This value can be the result of th… |
| 1.3.6.1.2.1.10.7.20.1.1.1.13 | ColumnpethPsePortPowerClassifications | read-only | current | Classification is a way to tag different terminals on the power over LAN network according to their power consumption. Devices such as IP telephones, WLAN acce… |
| 1.3.6.1.2.1.10.7.20.1.2 | TablepethPdPortTable | not-accessible | current | A table of objects that display and control the power characteristics power Ethernet ports on a Powered Device(PD) device. This group will be implemented in ma… |
| 1.3.6.1.2.1.10.7.20.1.2.1 | RowpethPdPortEntry | not-accessible | current | A set of objects that display and control the power characteristics of a Powered Device port. |
| 1.3.6.1.2.1.10.7.20.1.2.1.1 | ColumnpethPdPortIndex | not-accessible | current | An index value that uniquely identifies an interface to a PD device. The interface identified by a particular value of this index is the same interface as iden… |
| 1.3.6.1.2.1.10.7.20.1.2.1.2 | ColumnpethPdPortPowerPairs | read-only | current | Describes the pairs in use. A value of signal(1) menas that the signal pairs only are in use. A value of spare(2) means that the spare pairs only are in use. A… |
| 1.3.6.1.2.1.10.7.20.1.2.1.3 | ColumnpethPdPortDetectionOperStatus | read-only | current | Describes the operational status of the port detection. The value off(1) means that the port does not receive power and the detection algorithm might still be … |
| 1.3.6.1.2.1.10.7.20.1.2.1.4 | ColumnpethPdPortType | read-only | current | The type of the device. A management application may read the value of this variable and use it for setting the corresponding value of pethPsePortType of the p… |
| 1.3.6.1.2.1.10.7.20.1.3 | NodepethMainPseObjects | |||
| 1.3.6.1.2.1.10.7.20.1.3.1 | TablepethMainPseTable | not-accessible | current | A table of objects that display and control the Main power on a PSE device. |
| 1.3.6.1.2.1.10.7.20.1.3.1.1 | RowpethMainPseEntry | not-accessible | current | A set of objects that display and control the Main power of a PSE. |
| 1.3.6.1.2.1.10.7.20.1.3.1.1.1 | ColumnpethMainPseGroupIndex | not-accessible | current | This variable uniquely identifies the group to which power Ethernet PSE is connected. Group means box in the stack, module in a rack. It is recommended that th… |
| 1.3.6.1.2.1.10.7.20.1.3.1.1.2 | ColumnpethMainPsePower | read-write | current | The nominal power of the PSE expressed in Watts. |
| 1.3.6.1.2.1.10.7.20.1.3.1.1.3 | ColumnpethMainPseOperStatus | read-only | current | The operational status of the main PSE. |
| 1.3.6.1.2.1.10.7.20.1.3.1.1.4 | ColumnpethMainPseConsumptionPower | read-only | current | Measured usage power expressed in Watts. |
| 1.3.6.1.2.1.10.7.20.1.3.1.1.5 | ColumnpethMainPseBackupPresent | read-only | current | This value reflects the presence and status of a backup PSE . |
| 1.3.6.1.2.1.10.7.20.1.3.1.1.6 | ColumnpethMainPseBackupActivated | read-only | current | This variable reflects the activation status of the backup PSE |
| 1.3.6.1.2.1.10.7.20.1.3.1.1.7 | ColumnpethMainPseUsageThreshold | read-write | current | The usage threshold expressed in percents for comparing the measured power and initiating an alarm if the threshold is exceeded. |
| 1.3.6.1.2.1.10.7.20.1.4 | NodepethTrapsControl | |||
| 1.3.6.1.2.1.10.7.20.1.4.1 | TablepethTrapsControlTable | not-accessible | current | A table of objects that display and control the Main power on a PSE device. |
| 1.3.6.1.2.1.10.7.20.1.4.1.1 | RowpethTrapsControlEntry | not-accessible | current | A set of objects that control the Trap events. |
| 1.3.6.1.2.1.10.7.20.1.4.1.1.1 | ColumnpethTrapsControlGroupIndex | not-accessible | current | This variable uniquely identifies the group. Group means box in the stack, or module in a rack. It is recommended that the value 1 is used for non-modular devi… |
| 1.3.6.1.2.1.10.7.20.1.4.1.1.2 | ColumnpethTrapsControlEnable | read-write | current | Enable Traps from Agent |
| 1.3.6.1.2.1.10.7.20.2 | NodepethNotifications | |||
| 1.3.6.1.2.1.10.7.20.2.1 | NotificationpethPsePortOnOffTrap | current | This trap indicate if Pse Port is delivering or not power to the PD. | |
| 1.3.6.1.2.1.10.7.20.2.2 | NotificationpethPsePortDenyTrap | current | This trap indicate Port Deny service. | |
| 1.3.6.1.2.1.10.7.20.2.3 | NotificationpethPsePortStatusTrap | current | This trap indicate Port Change Status. | |
| 1.3.6.1.2.1.10.7.20.2.4 | NotificationpethMainPseBackUpActivatedTrap | current | This trap indicates that BackUp PSE is Activated . | |
| 1.3.6.1.2.1.10.7.20.2.5 | NotificationpethMainPowerUsageTrap | current | This trap indicate PSE Threshold usage indication . | |
| 1.3.6.1.2.1.10.7.20.3 | NodepethConformance | |||
| 1.3.6.1.2.1.10.7.20.3.1 | NodepethCompliances | |||
| 1.3.6.1.2.1.10.7.20.3.1.1 | CompliancepethCompliance | current | Describes the requirements for conformance to the Power Ethernet MIB. | |
| 1.3.6.1.2.1.10.7.20.3.2 | NodepethGroups | |||
| 1.3.6.1.2.1.10.7.20.3.2.1 | GrouppethPsePortGroup | current | PSE Port Objects. | |
| 1.3.6.1.2.1.10.7.20.3.2.2 | GrouppethPdPortGroup | current | PD Port Objects. | |
| 1.3.6.1.2.1.10.7.20.3.2.3 | GrouppethMainPseGroup | current | Main PSE Objects. | |
| 1.3.6.1.2.1.10.7.20.3.2.4 | GrouppethTrapsControlGroup | current | Trap Control Objects. |