MIB Viewer

PHIHONG-PoE-MIB

52 objects
No module-level DESCRIPTION found.
Imported Objects
SNMPv2-SMIenterprises Gauge32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
SNMPv2-TCDisplayString TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.24852Nodephihong
1.3.6.1.4.1.24852.2NodepoeProduct
1.3.6.1.4.1.24852.2.1ScalarpoeProductsPartread-onlycurrentthe POE controller Part.
1.3.6.1.4.1.24852.2.2NodepoeSystem
1.3.6.1.4.1.24852.2.2.1ScalarpoeSystemActionHubResetwrite-onlycurrentReset the POE controller.
1.3.6.1.4.1.24852.2.2.2ScalarpoeSystemActionHubRestoreFactoryDefaultwrite-onlycurrentRestore Factory Default to flash. resetpassword means when users forget the password,they can use this entry, and all of the snmp module parameters will be set…
1.3.6.1.4.1.24852.2.2.3ScalarpoeSystemActionHubSaveConfigurationwrite-onlycurrentSave the POE parameters to flash
1.3.6.1.4.1.24852.2.2.4ScalarpoeSystemAllPortPowerEnablewrite-onlycurrentEnables power supply in all port. Setting this object at a value enable(2) enables power and detection mechanism for all port. Setting this object at a value d…
1.3.6.1.4.1.24852.2.2.6ScalarpoeSystemHWVersionread-onlycurrentSystem hardware version for the Main board
1.3.6.1.4.1.24852.2.2.7ScalarpoeSystemNumberOfChannelread-onlycurrentNumber of ports in the system
1.3.6.1.4.1.24852.2.2.8ScalarpoeSystemProductPartNumberread-onlycurrentSystem Part Number for PowerHub
1.3.6.1.4.1.24852.2.2.10ScalarpoeSystemFirmwareVersionread-onlycurrentSystem firmware version for the POE
1.3.6.1.4.1.24852.2.2.11ScalarpoeSystemDescriptionread-writecurrentSystem Description 10 characters
1.3.6.1.4.1.24852.2.2.12ScalarpoeSystemConsumptionPowerread-onlycurrentMeasured usage power expressed in Watts.
1.3.6.1.4.1.24852.2.2.13ScalarpoeSystemControlACPowerread-writecurrentdescribes the maximum available power in Watts to be supplied by the AC backup source to this device.
1.3.6.1.4.1.24852.2.2.14ScalarpoeSystemControlDCPowerread-writecurrentdescribes the maximum available power in Watts to be supplied by the DC backup source to this device.
1.3.6.1.4.1.24852.2.2.15ScalarpoeSystemControlBothPowerread-writecurrentdescribes the maximum available power in Watts to be supplied by Both AC and DC backup source to this device.
1.3.6.1.4.1.24852.2.2.16ScalarpoeSystemParametersread-writecurrent1st char:Knokoff enable,2nd char:AC Disconnect enable,3th char:Disable Power Management
1.3.6.1.4.1.24852.2.2.17ScalarpoeSystemSnmpVersionread-onlycurrentThe software version for the SNMP device
1.3.6.1.4.1.24852.2.2.18ScalarpoeSystemPerPortPowerEnableread-writecurrentEnables power supply in all port. Setting this object at a value enable(2) enables power and detection mechanism for all port. Setting this object at a value d…
1.3.6.1.4.1.24852.2.2.19ScalarpoeSystemStatusread-onlycurrentThe status of the POE.
1.3.6.1.4.1.24852.2.3TablepoePortTablenot-accessiblecurrent
1.3.6.1.4.1.24852.2.3.1RowpoePortEntrynot-accessiblecurrentport entry containing data regarding a particular port
1.3.6.1.4.1.24852.2.3.1.1ColumnpoePortIndexread-onlycurrentA unique value for each port.
1.3.6.1.4.1.24852.2.3.1.2ColumnpoePortPowerEnableread-writecurrentEnables power supply on this port. Setting this object at a value enable(2) enables power and detection mechanism for this port. Setting this object at a value…
1.3.6.1.4.1.24852.2.3.1.3ColumnpoePortControlMaxPowerread-writecurrentThis command specifies the max power in [mWatts] to that port. IF you set this value it will take out this port from the auto mode. The value MUST be more then…
1.3.6.1.4.1.24852.2.3.1.6ColumnpoePortDescriptionread-writecurrentPort Description 10 characters
1.3.6.1.4.1.24852.2.3.1.7ColumnpoePortDetectionStatusread-onlycurrentPort Detection, show the detection status of each port
1.3.6.1.4.1.24852.2.3.1.8ColumnpoePortPowerClassificationsread-onlycurrentPort Power Classifications, show the classification of each port
1.3.6.1.4.1.24852.2.3.1.9ColumnpoePortPowerDetectionControlread-writecurrentPort Power Detection Control, enable or disable the Power Limit for Management
1.3.6.1.4.1.24852.2.3.1.10ColumnpoePortPowerPriorityread-writecurrentPort Power Priority, show the priority of each port
1.3.6.1.4.1.24852.2.3.1.11ColumnpoePortPowerread-onlycurrentPort Actual Power (in mWattes).
1.3.6.1.4.1.24852.2.3.1.12ColumnpoePortVoltageread-onlycurrentPort Voltage (in dVoltage).
1.3.6.1.4.1.24852.2.3.1.13ColumnpoePortCurrentread-onlycurrentPort Current (in mAmps).
1.3.6.1.4.1.24852.2.3.1.14ColumnpoePortResistanceread-onlycurrentPort Resistance (in ohms).
1.3.6.1.4.1.24852.2.3.1.15ColumnpoePortFlagsread-onlycurrent1st char:classification(0-3),2nd char:Port bypass detection enable,3th char:Port bypass classifiation enable,4th cahr:Port bypass powerup enable,5th char:Port …
1.3.6.1.4.1.24852.2.3.1.16ColumnpoePortBypassFlagsread-writecurrent1st char:Port bypass detection enable,2nd char:Port bypass classifiation enable,3th cahr:Port bypass powerup enable,4th char:Port bypass sampling enable.
1.3.6.1.4.1.24852.2.3.1.17ColumnpoePortUseClassificationforPowerLimitread-writecurrentUse Port classification for power limit , enable or disable the Port classification for power limit.
1.3.6.1.4.1.24852.2.3.1.18ColumnpoePortLegacyDetectionread-writecurrentUse Port legacy detection , enable or disable the Port legacy detection.
1.3.6.1.4.1.24852.2.4TablepoeTrapsControlTablenot-accessiblecurrentA table of objects that display and control the Traps on a PSM device.
1.3.6.1.4.1.24852.2.4.1RowpoeTrapsControlEntrynot-accessiblecurrentA set of objects that control the Trap events.
1.3.6.1.4.1.24852.2.4.1.1ColumnpoeTrapsControlGroupIndexnot-accessiblecurrentThis variable uniquely identifies the group.
1.3.6.1.4.1.24852.2.4.1.2ColumnpoeTrapsControlEnableread-writecurrentEnable Traps from Agent
1.3.6.1.4.1.24852.2.5NodepoeTraps
1.3.6.1.4.1.24852.2.5.1NotificationpoePortHWFailTrapcurrentThis trap indicate UV0v failure /UV0v Spike failure /Device A2d failure.
1.3.6.1.4.1.24852.2.5.2NotificationpoePortPeakOverCurrentTrapcurrentThis trap indicate peak over current failure.
1.3.6.1.4.1.24852.2.5.3NotificationpoePortOverloadTrapcurrentThis trap indicate overload failure. If you put at least 400mA on the output, you will see if your traps work
1.3.6.1.4.1.24852.2.5.4NotificationpoePortDiscoveryFailTrapcurrentThis trap indicate Discovery failure/ Discovery VA2 failure/Discovery RA2 failure/Sample Discovery A2d Failure.
1.3.6.1.4.1.24852.2.5.5NotificationpoePortClassificationFailTrapcurrentThis trap indicate Class Violation failure/ Classification A2d failure.
1.3.6.1.4.1.24852.2.5.6NotificationpoePortDisconnectTrapcurrentThis trap indicate port is disconnected.
1.3.6.1.4.1.24852.2.5.7NotificationpoePortVoltageFailTrapcurrentThis trap indicate if PSM Port is no voltage failure.
1.3.6.1.4.1.24852.2.5.8NotificationpoeSystemOverheatTrapcurrentThis trap indicate if PSM is overheat.