PLAINTREE-SWITCH-MIB
53 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.295 | Nodevendor | |||
| 1.3.6.1.4.1.295.3 | Nodeswitch | |||
| 1.3.6.1.4.1.295.3.1 | NodeswitchHardware | |||
| 1.3.6.1.4.1.295.3.1.1 | NodeswitchChassis | |||
| 1.3.6.1.4.1.295.3.1.2 | NodeswitchPort | |||
| 1.3.6.1.4.1.295.3.1.2.1 | NodeswitchEthernetPort | |||
| 1.3.6.1.4.1.295.3.1.2.2 | NodeswitchWaveBusPort | |||
| 1.3.6.1.4.1.295.3.1.2.3 | NodeswitchFddiPort | |||
| 1.3.6.1.4.1.295.3.2 | NodeswitchSoftware | |||
| 1.3.6.1.4.1.295.3.2.1 | NodeswitchInfo | |||
| 1.3.6.1.4.1.295.3.2.1.1 | TableswitchBasicTable | not-accessible | mandatory | Basic information about the switch |
| 1.3.6.1.4.1.295.3.2.1.1.1 | RowswitchBasicEntry | not-accessible | mandatory | Identification information about a particular port on the switch. |
| 1.3.6.1.4.1.295.3.2.1.1.1.1 | ColumnswitchProductCode | read-only | mandatory | An ASCII string giving the product code of the switch. |
| 1.3.6.1.4.1.295.3.2.1.1.1.2 | ColumnswitchSerialNumber | read-only | mandatory | An ASCII string giving the switch serial number. |
| 1.3.6.1.4.1.295.3.2.1.1.1.3 | ColumnswitchPlaceOfManufacture | read-only | mandatory | A number identifying where the switch was built. |
| 1.3.6.1.4.1.295.3.2.1.1.1.4 | ColumnswitchDateOfManufacture | read-only | mandatory | An ASCII string giving the date of manufacture of the switch. |
| 1.3.6.1.4.1.295.3.2.1.1.1.5 | ColumnswitchMacAddress | read-only | mandatory | The IEEE 802 MAC address of the switch. |
| 1.3.6.1.4.1.295.3.2.1.1.1.6 | ColumnswitchCodeVersion | read-only | mandatory | An ASCII string giving the version number of the switch software. |
| 1.3.6.1.4.1.295.3.2.1.1.1.7 | ColumnswitchBpeEnabled | read-write | mandatory | Setting this variable to TRUE (1) causes the bridge protocol engine to perform the Spanning Tree Protocol as defined in IEEE802.1d. Setting this variable to FA… |
| 1.3.6.1.4.1.295.3.2.1.1.1.8 | ColumneraseSwitchSnmpConfigInfo | read-write | mandatory | Setting this variable to TRUE (1) causes the switch to erase its SNMP configuration information both from memory and from permanent store. The switch the reque… |
| 1.3.6.1.4.1.295.3.2.1.1.1.9 | ColumnrestoreSwitchDot1dDefaults | read-write | mandatory | Setting this variable to TRUE (1) causes the BPE to restore the default spanning tree values given in the IEEE 802.1d specification. This resets all writeable … |
| 1.3.6.1.4.1.295.3.2.1.1.1.10 | ColumnperformSwitchReset | read-write | mandatory | Setting this variable to TRUE (1) causes the switch to perform a cold restart. As a result of this action a coldRestart trap will be sent. Setting this variabl… |
| 1.3.6.1.4.1.295.3.2.1.1.1.11 | ColumnswitchIdentPressed | read-only | mandatory | This variable is TRUE (1) if the IDENTIFY button on the switch has been pressed since the variable was last read. After this variable has been read it will be … |
| 1.3.6.1.4.1.295.3.2.1.1.1.12 | ColumnageFilterDatabase | read-write | mandatory | Setting this variable to FALSE (0) causes the switch to stop aging out entries from its filter database. Setting this variable to TRUE (1) causes the switch to… |
| 1.3.6.1.4.1.295.3.2.1.1.1.13 | ColumnclearStatistics | read-write | mandatory | Setting this variable to TRUE (1) clears the traffic statistics accumulators in the switch. Setting this variable to any other value has no effect. The variabl… |
| 1.3.6.1.4.1.295.3.2.1.1.1.100 | ColumnswitchBasicIndex | not-accessible | mandatory | This is a dummy variable which provides a meta-index for the Basic Information Table. |
| 1.3.6.1.4.1.295.3.2.1.2 | TableswitchPortTable | not-accessible | mandatory | Identification information about the ports on a switch. |
| 1.3.6.1.4.1.295.3.2.1.2.1 | RowswitchPortEntry | not-accessible | mandatory | Identification information about a particular port on the switch. |
| 1.3.6.1.4.1.295.3.2.1.2.1.1 | ColumnswitchPortIndex | read-only | mandatory | The number of the port to which the management information applies. |
| 1.3.6.1.4.1.295.3.2.1.2.1.2 | ColumnswitchPortProductCode | read-only | mandatory | An ASCII string giving the product code of the card on which this port is located. |
| 1.3.6.1.4.1.295.3.2.1.2.1.3 | ColumnswitchPortSerialNumber | read-only | mandatory | An ASCII string giving the serial number of the card on which this port is located. |
| 1.3.6.1.4.1.295.3.2.1.2.1.4 | ColumnswitchPortPlaceOfManufacture | read-only | mandatory | A number identifying where the card on which this port is located was built. |
| 1.3.6.1.4.1.295.3.2.1.2.1.5 | ColumnswitchPortDateOfManufacture | read-only | mandatory | An ASCII string giving the date of manufacture of the card on which this port is located. |
| 1.3.6.1.4.1.295.3.2.1.2.1.6 | ColumnswitchPortState | read-only | mandatory | An ASCII string giving the port's operational state. |
| 1.3.6.1.4.1.295.3.2.1.2.1.7 | ColumnswitchPortHighSensitivity | read-write | mandatory | This variable is only valid if the port is an Ethernet port. If this variable is set to TRUE (1), the receiver of the Ethernet NIC controlling the port is set … |
| 1.3.6.1.4.1.295.3.2.1.2.1.8 | ColumnrestoreFddiMibDefaults | read-write | mandatory | This variable is ony valid if the port is an FDDI station. Setting this variable to TRUE (1) causes the agent to restore the default MIB values given in the AN… |
| 1.3.6.1.4.1.295.3.2.1.2.1.9 | ColumntranslateAllEthertypes | read-write | mandatory | This variable is only valid if the port is an FDDI port. If this variable is set to TRUE (1), the Bridge Tunnel Encapsulation Protocol will be applied to frame… |
| 1.3.6.1.4.1.295.3.2.1.2.1.10 | ColumnswitchPortTxFrames | read-only | mandatory | This counter is incremented by one for each frame transmitted to the network segment attached to the port. |
| 1.3.6.1.4.1.295.3.2.1.2.1.11 | ColumnswitchPortRxFrames | read-only | mandatory | This counter is incremented by one for each valid frame received from the network segment attached to the port. |
| 1.3.6.1.4.1.295.3.2.1.2.1.12 | ColumnswitchPortFcsErrors | read-only | mandatory | This counter is incremented by one for each received frame which failed its FCS check. |
| 1.3.6.1.4.1.295.3.2.1.2.1.13 | ColumnswitchPortFilterDiscards | read-only | mandatory | The number of frames received on this port which have been discarded due to the filtering action of the port's bridge circuit. |
| 1.3.6.1.4.1.295.3.2.1.2.1.14 | ColumnswitchPortDelayExceededDiscards | read-only | mandatory | The number of frames discarded by this port due to excessive transit delay through the switch. It reports the same value as the object dot1dBasePortDelayExceed… |
| 1.3.6.1.4.1.295.3.2.1.2.1.15 | ColumnswitchPortMtuExceededDiscards | read-only | mandatory | The number of frames discarded by this port due to excessive size. It is the same value reported in the object dot1dBasePortMtuExceededDiscards in the Bridge M… |
| 1.3.6.1.4.1.295.3.2.1.3 | TableswitchSelectiveTranslationTable | not-accessible | mandatory | The Selective Translation Table as defined in IEEE 802.1h. |
| 1.3.6.1.4.1.295.3.2.1.3.1 | RowtranslationTableEntry | not-accessible | mandatory | One entry in the STT. |
| 1.3.6.1.4.1.295.3.2.1.3.1.1 | ColumntranslationTablePortIndex | read-only | mandatory | The table index - the port number on which the STT resides. |
| 1.3.6.1.4.1.295.3.2.1.3.1.2 | ColumntranslationTableEthertype1 | read-write | mandatory | The first Ethertype for which the Bridge Tunnel Encapsulation Protocol should be used. |
| 1.3.6.1.4.1.295.3.2.1.3.1.3 | ColumntranslationTableEntryValid1 | read-write | mandatory | If this variable is set to TRUE (1), the Bridge Tunnel Encapsulation Protocol will be applied to frames containing the first Ethertype. If this variable is set… |
| 1.3.6.1.4.1.295.3.2.1.3.1.4 | ColumntranslationTableEthertype2 | read-write | mandatory | The second Ethertype for which the Bridge Tunnel Encapsulation Protocol should be used. |
| 1.3.6.1.4.1.295.3.2.1.3.1.5 | ColumntranslationTableEntryValid2 | read-write | mandatory | If this variable is set to TRUE (1), the Bridge Tunnel Encapsulation Protocol will be applied to frames containing the second Ethertype. If this variable is se… |
| 1.3.6.1.4.1.295.3.2.1.3.1.6 | ColumntranslationTableEthertype3 | read-write | mandatory | The third Ethertype for which the Bridge Tunnel Encapsulation Protocol should be used. |
| 1.3.6.1.4.1.295.3.2.1.3.1.7 | ColumntranslationTableEntryValid3 | read-write | mandatory | If this variable is set to TRUE (1), the Bridge Tunnel Encapsulation Protocol will be applied to frames containing the third Ethertype. If this variable is set… |
| 1.3.6.1.4.1.295.9 | NodeswitchTouched | This trap is generated when the IDENTIFY button on the switch is pressed. The agent throttles the generation of consecutive switchTouched traps so that there i… |