MIB Viewer

RAD-BROADBAND-IF-MIB

117 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.164.3.1.6.8NodebroadbandIf
1.3.6.1.4.1.164.3.1.6.8.1NodebdbandConfig
1.3.6.1.4.1.164.3.1.6.8.1.1TableprtBdbandIndTablenot-accessiblecurrentThe Indication Signal table.
1.3.6.1.4.1.164.3.1.6.8.1.1.1RowprtBdbandIndEntrynot-accessiblecurrentAn entry in the Indication Signal table.
1.3.6.1.4.1.164.3.1.6.8.1.1.1.1ColumnprtBdbandCnfgIdxread-onlycurrentThis object indicates the Idx of the Agent Cnfg the following objects refer. 255=Temporary Cnfg (when relevant, Set is done only to this configuration). For Ag…
1.3.6.1.4.1.164.3.1.6.8.1.1.1.2ColumnprtBdbandIdxread-onlycurrentThis object indicates a unique port or interface number. For numbering, see product's spec. For some products, the numbering can equal ifIndex.
1.3.6.1.4.1.164.3.1.6.8.1.1.1.3ColumnprtBdbandIndSigread-onlycurrentThis object indicates a unique Indication Signal. ais(1) = AIS = Alarm Indication Signal. rdi(2) = RDI = Remote Defect Indication.
1.3.6.1.4.1.164.3.1.6.8.1.1.1.4ColumnprtBdbandIndEventread-onlycurrentThis object indicates a unique Event that can cause the Indication Signal. slm(2) = SLM = Signal Label Mismatch eed(4) = EED = Excessive Error Defect pathTrace…
1.3.6.1.4.1.164.3.1.6.8.1.1.1.5ColumnprtBdbandIndSigEnableread-createcurrentThis object allows user to define if the event specified by prtBdbandIndEvent will cause creation of the Indication Signal specified by prtBdbandIndSig or not.…
1.3.6.1.4.1.164.3.1.6.8.1.1.1.6ColumnprtBdbandRowStatusread-createcurrentCreation/Deletion of rows in the table.
1.3.6.1.4.1.164.3.1.6.8.1.2TableprtPhyConfigTablenot-accessiblecurrentThe Phy Config table. Used now for Phy25.6 Mbps.
1.3.6.1.4.1.164.3.1.6.8.1.2.1RowprtPhyConfigEntrynot-accessiblecurrentAn entry in the Phy Config table.
1.3.6.1.4.1.164.3.1.6.8.1.2.1.1ColumnprtPhyTimeElapsedread-onlycurrentThe number of seconds that have elapsed since the beginning of the current error-measurement period.
1.3.6.1.4.1.164.3.1.6.8.1.2.1.2ColumnprtPhyValidIntervalsread-onlycurrentThe number of previous intervals for which valid data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in …
1.3.6.1.4.1.164.3.1.6.8.2NodeprtPhyPerfHistory
1.3.6.1.4.1.164.3.1.6.8.2.1TableprtPhyCurrentTablenot-accessiblecurrentThe 25.6 Mbps Section/Line Current table.
1.3.6.1.4.1.164.3.1.6.8.2.1.1RowprtPhyCurrentEntrynot-accessiblecurrentAn entry in the 25.6 Mbps Line Current table. ifIndex of the line 25.6 Mbps layer of type 25.6 Mbps.
1.3.6.1.4.1.164.3.1.6.8.2.1.1.1ColumnprtPhyCurrentLOSread-onlycurrentThe counter associated with the number of Loss Of Sync seconds, encountered by a 25.6 Mbps interface in the current 15 minute interval.
1.3.6.1.4.1.164.3.1.6.8.2.1.1.2ColumnprtPhyCurrentLSVread-onlycurrentThe counter associated with the number of Line symbol violation seconds, encountered by a 25.6 Mbps interface in the current 15 minute interval.
1.3.6.1.4.1.164.3.1.6.8.2.1.1.3ColumnprtPhyCurrentUASread-onlycurrentThe counter associated with the number of UAS encountered by a 25.6 Mbps interface in the current 15 minute interval.
1.3.6.1.4.1.164.3.1.6.8.2.1.1.4ColumnprtPhyCurrentSESread-onlycurrentThe counter associated with the number of SES encountered by a 25.6 Mbps interface in the current 15 minute interval.
1.3.6.1.4.1.164.3.1.6.8.2.1.1.5ColumnprtPhyCurrentESread-onlycurrentThe number of Errored Seconds, encountered by a 25.6 Mbps interface in the current 15 minute interval.
1.3.6.1.4.1.164.3.1.6.8.2.1.1.6ColumnprtPhyCurrentStatusread-onlycurrentThe statuses of the current interval: 0 - O.K. 1 - The link has been switched by a redundancy mechanism. 2 - Module is in/out. 4 - Empty - card is out.
1.3.6.1.4.1.164.3.1.6.8.2.1.1.7ColumnprtPhyCurrentLOFread-onlycurrentThe number of Loss of Frames, encountered by an interface in the current 15 minute interval.
1.3.6.1.4.1.164.3.1.6.8.2.2TableprtPhyIntervalTablenot-accessiblecurrentThe Line Interval table.
1.3.6.1.4.1.164.3.1.6.8.2.2.1RowprtPhyIntervalEntrynot-accessiblecurrentAn entry in the 25.6 Mbps Line Interval table. ifIndex of the line 25.6 Mbps layer of type 25.6 Mbps.
1.3.6.1.4.1.164.3.1.6.8.2.2.1.1ColumnprtPhyIntervalNumberread-onlycurrentA number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that …
1.3.6.1.4.1.164.3.1.6.8.2.2.1.2ColumnprtPhyIntervalLOSread-onlycurrentThe counter associated with the number of Loss Of Sync seconds , encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals.
1.3.6.1.4.1.164.3.1.6.8.2.2.1.3ColumnprtPhyIntervalLSVread-onlycurrentThe counter associated with the number of line symbol violation seconds , encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute …
1.3.6.1.4.1.164.3.1.6.8.2.2.1.4ColumnprtPhyIntervalUASread-onlycurrentThe counter associated with the number of UAS encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals.
1.3.6.1.4.1.164.3.1.6.8.2.2.1.5ColumnprtPhyIntervalSESread-onlycurrentThe counter associated with the number of SES encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals.
1.3.6.1.4.1.164.3.1.6.8.2.2.1.6ColumnprtPhyIntervalESread-onlycurrentThe number of Errored Seconds, encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals.
1.3.6.1.4.1.164.3.1.6.8.2.2.1.7ColumnprtPhyIntervalStatusread-onlycurrentThe statuses of the current interval: 0 - O.K. 1 - The link has been switched by a redundancy mechanism. 2 - Module is in/out. 4 - Empty - card is out.
1.3.6.1.4.1.164.3.1.6.8.2.2.1.8ColumnprtPhyIntervalLOFread-onlycurrentThe number of Loss of Frames, encountered by an interface in one of the previous 96, individual 15 minute intervals.
1.3.6.1.4.1.164.3.1.6.9Noder2If
1.3.6.1.4.1.164.3.1.6.9.1Noder2ProfileCnfg
1.3.6.1.4.1.164.3.1.6.9.1.1Tabler2CnfgTablenot-accessiblecurrentThe write operation into the Table Objects is valid only to the TmpCnfg entry.
1.3.6.1.4.1.164.3.1.6.9.1.1.1Rowr2CnfgEntrynot-accessiblecurrentAn entry in table.
1.3.6.1.4.1.164.3.1.6.9.1.1.1.1Columnr2CnfgIdxread-onlycurrentThis attribute indicates the Idx of the Cnfg being accessed. 255 = TmpCnfg. 1 = Current Cnfg. Write is allowed only to TmpCnfg.
1.3.6.1.4.1.164.3.1.6.9.1.1.1.2Columnr2CnfgProfileIdxread-onlycurrentProfile Index. Valid values: 1..5 Only instances of profiles that are defined having agnSigProfType=r2Cas will exist in this table.
1.3.6.1.4.1.164.3.1.6.9.1.1.1.3Columnr2Moderead-createcurrentR2 Mode. auto - in this mode, default value of timers will be used by R2, according to the selected r2Country. manual - in this mode, user can change the value…
1.3.6.1.4.1.164.3.1.6.9.1.1.1.4Columnr2Countryread-createcurrentR2 Country. R2 Timers can have different range of values and defaults for each country. When r2Mode=auto, the default value is used by R2 according to this sel…
1.3.6.1.4.1.164.3.1.6.9.1.1.1.5Columnr2Delayread-createcurrentThis object enables user to configure the link as satellite or terrestrial. The seize acknowledge detect timing is much shorter (msec) for terrestrial link tha…
1.3.6.1.4.1.164.3.1.6.9.1.1.1.6Columnr2MeteringIndread-createcurrentWhich Bit will be used for Metering Indication.
1.3.6.1.4.1.164.3.1.6.9.1.1.1.7Columnr2BreakMakeRatioread-createcurrentThis object describes the Break-Make Ratio of Pulse Duration, in [msec]. RW only when r2Mode=manual.
1.3.6.1.4.1.164.3.1.6.9.1.1.1.8Columnr2ReleaseGuardT2read-createcurrentRelease Guard timing T2. Release guard timing before going to idle, in [msec]. RW only when r2Mode=manual.
1.3.6.1.4.1.164.3.1.6.9.1.1.1.9Columnr2Regretread-createcurrentRegret duration, in [sec]. RW only when r2Mode=manual.
1.3.6.1.4.1.164.3.1.6.9.1.1.1.10Columnr2SeizeDetectread-createcurrentSeize Detect. Timer of the R2 incoming side. Minimum duration to detect a valid seizure, in [msec]. RW only when r2Mode=manual.
1.3.6.1.4.1.164.3.1.6.9.1.1.1.11Columnr2SeizeAckDelayread-createcurrentTimer of the R2 incoming side. Delay before sending a valid seize ack signal, in [msec]. Applicable only when r2Mode=manual. only when r2Mode=manual.
1.3.6.1.4.1.164.3.1.6.9.1.1.1.12Columnr2ClearBackDetectread-createcurrentTimer of the R2 incoming side. Minimum duration to recognize a valid clear-back, in [msec]. RW only when r2Mode=manual.
1.3.6.1.4.1.164.3.1.6.9.1.1.1.13Columnr2ClearFwdDetectread-createcurrentTimer of the R2 incoming side. Minimum duration to recognize a valid clear-forward, in [msec]. RW only when r2Mode=manual.
1.3.6.1.4.1.164.3.1.6.9.1.1.1.14Columnr2FaultDetectread-createcurrentTimer of the R2 incoming side. Minimum duration to recognize a block signal, in [msec]. RW only when r2Mode=manual.
1.3.6.1.4.1.164.3.1.6.9.1.1.1.15Columnr2FaultRemoveDetectread-createcurrentTimer of the R2 incoming side. Minimum duration to recognize a valid block removal signal, in [msec]. RW only when r2Mode=manual.
1.3.6.1.4.1.164.3.1.6.9.1.1.1.16Columnr2MeterPulseDurationread-createcurrentTimer of the R2 incoming side. Duration of metering pulse to be sent, in [msec]. RW only when r2Mode=manual.
1.3.6.1.4.1.164.3.1.6.9.1.1.1.17Columnr2SeizeAckWaitread-createcurrentTimer of the R2 outgoing side. Minimum duration to receive seizure acknowledge signal, in [msec]. RW only when r2Mode=manual.
1.3.6.1.4.1.164.3.1.6.9.1.1.1.18Columnr2SeizeAckDetectread-createcurrentTimer of the R2 outgoing side. Minimum duration to recognize a valid seizure acknowledge signal, in [msec]. RW only when r2Mode=manual.
1.3.6.1.4.1.164.3.1.6.9.1.1.1.19Columnr2AnswerDetectread-createcurrentTimer of the R2 outgoing side. Minimum duration to recognize a valid answer signal, in [msec]. RW only when r2Mode=manual.
1.3.6.1.4.1.164.3.1.6.9.1.1.1.20Columnr2BlockRemoveDetectread-createcurrentTimer of the R2 outgoing side. Minimum duration to recognize a valid block removal signal, in [msec]. RW only when r2Mode=manual.
1.3.6.1.4.1.164.3.1.6.9.1.1.1.21Columnr2MeterPulseDetectread-createcurrentTimer of the R2 outgoing side. Minimum duration of incoming meter pulse, in [msec]. RW only when r2Mode=manual.
1.3.6.1.4.1.164.3.1.6.9.1.1.1.22Columnr2ForcedDisconnectread-createcurrentTimer of the R2 outgoing side. Minimum duration to recognize disconnect signal, in [msec]. RW only when r2Mode=manual.
1.3.6.1.4.1.164.3.1.6.9.1.1.1.23Columnr2DisconnectAckread-createcurrentTimer of the R2 outgoing side. Minimum duration to recognize disconnect acknowledge signal, in [msec]. RW only when r2Mode=manual.
1.3.6.1.4.1.164.3.1.6.9.1.1.1.24Columnr2ReleaseGuardT1read-createcurrentTimer of the R2 outgoing side. Minimum duration to release guard, in [msec]. During this time, no new call can be initiated. RW only when r2Mode=manual.
1.3.6.1.4.1.164.3.1.6.9.1.1.1.25Columnr2CnfgRowStatusread-createcurrentThis object enables the user to add/delete entries to/from the table.
1.3.6.1.4.1.164.3.1.6.9.1.2Tabler2TsTablenot-accessiblecurrentThe write operation into the Table Objects is valid only to the TmpCnfg entry.
1.3.6.1.4.1.164.3.1.6.9.1.2.1Rowr2TsEntrynot-accessiblecurrentAn entry in table.
1.3.6.1.4.1.164.3.1.6.9.1.2.1.1Columnr2TsCnfgIdxread-onlycurrentThis attribute indicates the Idx of the Cnfg being accessed. 255 = TmpCnfg. 1 = Current Cnfg. Write is allowed only to TmpCnfg.
1.3.6.1.4.1.164.3.1.6.9.1.2.1.2Columnr2TsProfileIdxread-onlycurrentProfile Index. Valid values: 1..5 Only instances of profiles that are defined having agnSigProfType=r2Cas will exist in this table.
1.3.6.1.4.1.164.3.1.6.9.1.2.1.3Columnr2TsIdxread-onlycurrentTS Index. Valid values: 1..31
1.3.6.1.4.1.164.3.1.6.9.1.2.1.4Columnr2TsCallEnableread-createcurrentThis object indicates the Enabled Call direction for the specific TS.
1.3.6.1.4.1.164.3.1.6.9.1.2.1.5Columnr2TsMeteringread-createcurrentThis object indicates if the specific TS should support Metering.
1.3.6.1.4.1.164.3.1.6.9.1.2.1.6Columnr2TsRowStatusread-createcurrentThis object enables the user to add/delete entries to/from the table.
1.3.6.1.4.1.164.3.1.6.9.1.2.1.7Columnr2TsReversePolarityread-createcurrentThis object indicates if the specific TS should support Reverse Polarity.
1.3.6.1.4.1.164.3.1.6.9.2Noder2IfStatus
1.3.6.1.4.1.164.3.1.6.9.2.1Tabler2StatusTablenot-accessiblecurrentThe write operation into the Table Objects is valid only to the TmpCnfg entry.
1.3.6.1.4.1.164.3.1.6.9.2.1.1Rowr2StatusEntrynot-accessiblecurrentAn entry in table.
1.3.6.1.4.1.164.3.1.6.9.2.1.1.1Columnr2StatusSlotIdxread-onlycurrentSlot Index
1.3.6.1.4.1.164.3.1.6.9.2.1.1.2Columnr2StatusPortIdxread-onlycurrentThis object indicates a unique port number of the ML having R2 interface. Valid values: exPrt1 (1)..exPrt4 (4)
1.3.6.1.4.1.164.3.1.6.9.2.1.1.3Columnr2StatusTsIdxread-onlycurrentTime Slot index.
1.3.6.1.4.1.164.3.1.6.9.2.1.1.4Columnr2StatusSigDirectionread-onlycurrentR2 Time Slot Signaling Direction.
1.3.6.1.4.1.164.3.1.6.9.2.1.1.5Columnr2StatusTsStateread-onlycurrentR2 TS State
1.3.6.1.4.1.164.3.1.6.9.2.1.1.6Columnr2StatusProtocolStateread-onlycurrentR2 Protocol State.
1.3.6.1.4.1.164.12.7NodeatmLayer2
1.3.6.1.4.1.164.12.7.1TableatmLayer2XVclTablenot-accessiblecurrentThis table is an extension of VCL table, which is created for each LAN VCC.
1.3.6.1.4.1.164.12.7.1.1RowatmLayer2XVclEntrynot-accessiblecurrentConceptual row in atmVclTable. This table augments the RFC2515 VCL table.
1.3.6.1.4.1.164.12.7.1.1.1ColumnatmLayer2XVclConnModeread-createcurrentEach valid LAN VCC is either Main or Sub. This parameter is configured only once on creation of a LAN VCC. It can not be changed after creation. In order to ch…
1.3.6.1.4.1.164.12.7.1.1.2ColumnatmLayer2XVclGroupIdxread-onlycurrentThe group identifier. A VCC Group identifier = 0 if the VCC was not associated with a group yet. This value is updated according to the group identifier set by…
1.3.6.1.4.1.164.12.7.2TableatmLayer2GroupTablenot-accessiblecurrentThis table contains groups and their members. A group is a bundle of VCCs, which acts as different queues. Main and Sub VCCs should have the same ATM slot and …
1.3.6.1.4.1.164.12.7.2.1RowatmLayer2GroupEntrynot-accessiblecurrentConceptual row in atmLayer2GroupTable. The indexes: ifIndex, atmVclVpi and atmVclVci indicate the Network ATM End-Point. Upon a group creation, one Main VCC mu…
1.3.6.1.4.1.164.12.7.2.1.1ColumnatmLayer2GroupIdxread-onlycurrentThe group identifier. 0 is not a valid index.
1.3.6.1.4.1.164.12.7.2.1.2ColumnatmLayer2GroupRowStatusread-createcurrentCreation/Deletion of rows in the table, and indication of the entry's status.
1.3.6.1.4.1.164.12.7.2.1.3ColumnatmLayer2GroupConnModeread-onlycurrentEach valid LAN VCC is either Main or Sub as configured in atmLayer2XVclTable.
1.3.6.1.4.1.164.12.7.2.1.4ColumnatmLayer2GroupConnPriorityread-onlycurrentThis parameter is configured by atmLayer2PriorityRx from atmLayer2PriorityTable. Each bit in the Octet represents a specific priority as follows: MSB 7 6 5 4 3…
1.3.6.1.4.1.164.12.7.2.1.5ColumnatmLayer2GroupNameread-createcurrentGroup name. Configured by the user. The name is unique per system. For atmLayer2GroupIdx=0, the name will be null.
1.3.6.1.4.1.164.12.7.3TableatmLayer2PriorityTablenot-accessiblecurrentThis table maps all priorities inside a group. Several priorities might be mapped to the same VCC. Upon priority change, the agent will update the VCCs of the …
1.3.6.1.4.1.164.12.7.3.1RowatmLayer2PriorityEntrynot-accessiblecurrentConceptual row in atmLayer2PriorityTable. Each entry is a Network ATM End-Point per priority. Upon a group creation, all priorities are mapped to the Main VCC.…
1.3.6.1.4.1.164.12.7.3.1.1ColumnatmLayer2PriorityGroupIdxread-onlycurrentThe group identifier.
1.3.6.1.4.1.164.12.7.3.1.2ColumnatmLayer2PriorityRxread-onlycurrentThe priority values. The used values are 0-7, but since this value is part of the index of the table, and in order to avoid '0' as an index, the index syntax i…
1.3.6.1.4.1.164.12.7.3.1.3ColumnatmLayer2PriorityIfIndexread-createcurrentATM ifIndex of the network End-Point.
1.3.6.1.4.1.164.12.7.3.1.4ColumnatmLayer2PriorityVclVpiread-createcurrentVpi of the network End-Point.
1.3.6.1.4.1.164.12.7.3.1.5ColumnatmLayer2PriorityVclVciread-createcurrentVci of the network End-Point.
1.3.6.1.4.1.164.12.7.4ScalaratmLayer2GroupIndexNextread-onlycurrentThis object contains an appropriate value to be used for atmLayer2GroupIdx when creating entries in the atmLayer2GroupTable. The value 0 indicates that no unas…
1.3.6.1.4.1.164.12.7.5TableatmLayer2CfgTablenot-accessiblecurrentBridge configuration Table. This table supports multi-bridge and bridge features within an ATM device.
1.3.6.1.4.1.164.12.7.5.1RowatmLayer2CfgEntrynot-accessiblecurrentConceptual row in atmLayer2CfgTable. Each entry in this table contains the bridging attributes for both Ethernet and ATM sides. The interface index is the Ethe…
1.3.6.1.4.1.164.12.7.5.1.1ColumnatmLayer2CfgBridgingModeread-writecurrentBridging mode can be one of the following: ATM <> Ethernet - Bridging is between the Ethernet port and the ATM port (there is no bridging between VCs). ATM <> …
1.3.6.1.4.1.164.12.7.5.1.2ColumnatmLayer2CfgVlanModeread-writecurrentVLAN Mode. Upon Mode changing, all LAN VCCs will be deleted by the agent from all tables that include LAN VCCs.
1.3.6.1.4.1.164.12.7.5.1.3ColumnatmLayer2CfgAtmAcceptableFrameTyperead-writecurrentThe Frame Type that will be acceptable by the VCCs that are associated with this Ethernet port. Frames which don't match the selected type will be discarded. a…
1.3.6.1.4.1.164.12.7.5.1.4ColumnatmLayer2CfgAtmIngressFilteringread-writecurrentFor the VCCs that are associated with this Ethernet port, when this is true(1) the device will discard incoming frames for VLANs which do not include this Port…
1.3.6.1.4.1.164.12.7.5.1.5ColumnatmLayer2CfgAtmTxFrameTyperead-writecurrentThe Frame Type that will be transmitted by the VCCs that are associated with this Ethernet port. unTagged - The transmitted frames will be unTagged. tagged - T…
1.3.6.1.4.1.164.12.7.5.1.6ColumnatmLayer2CfgEthAcceptableFrameTyperead-writecurrentThe Frame Type that this Ethernet port will accept. (for ACE-52: the Frame Type that this Bridge will accept) This parameter is notApplicable for atmLayer2Vlan…
1.3.6.1.4.1.164.12.7.5.1.7ColumnatmLayer2CfgBridgeActionread-writecurrentThis object enables to perform the specified action on the selected port.
1.3.6.1.4.1.164.12.7.5.1.8ColumnatmLayer2CfgLearningModeread-writecurrentThis object specifies the mode of the learning process of a bridge. svl - Shared VLAN process. If an individual MAC Address is learned in one VLAN, this inform…
1.3.6.1.4.1.164.12.7.5.1.9ColumnatmLayer2CfgAgingTimeread-writecurrentThe timeout period in seconds for aging out dynamically learned forwarding information.
1.3.6.1.4.1.164.12.8NoderadAtmFr
1.3.6.1.4.1.164.12.8.1TablefrAtmIwfXConnectionTablenot-accessiblecurrentThis table is an extension of frAtmIwfXConnectionTable from RFC2955.
1.3.6.1.4.1.164.12.8.1.1RowfrAtmIwfXConnectionEntrynot-accessiblecurrentConceptual row in frAtmIwfXConnectionTable. This table augments the RFC2955.
1.3.6.1.4.1.164.12.8.1.1.1ColumnfrAtmIwfXConnModeread-createcurrentFR IWF Mode. service - Service InterWorking (FRF.8), network - Network InterWorking (FRF.5).
1.3.6.1.4.1.164.12.8.1.1.2ColumnfrAtmIwfXConnSscsDlciread-createcurrentThis parameter is relevant for frAtmIwfXConnMode=network (FRF.5) only. This parameter allow configuration of the FR SSCS DLCI that is transferred to the remote…