MIB Viewer

RAID-Adapter-MIB

195 objects
No module-level DESCRIPTION found.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.3582Nodelsi
1.3.6.1.4.1.3582.1NodemegaRaid
1.3.6.1.4.1.3582.1.1NodemegaRaidMib
1.3.6.1.4.1.3582.1.1.1TableadapterTablenot-accessibleoptionalA List of Adapter Entries containing Information/Properties about the Adapters in the System.
1.3.6.1.4.1.3582.1.1.1.1RowadapterEntrynot-accessibleoptionalAn entry in the Adapter Table. Each Entry corresponds to one Adapter in the System.
1.3.6.1.4.1.3582.1.1.1.1.1ColumnadpAdapterNumberread-onlyoptionalThe Adapter Number for this Instance of Adapter Object. This Entry in the Table, contains Information about the Adapter Number specified by this variable.
1.3.6.1.4.1.3582.1.1.1.1.2ColumnnumLogicalDrivesread-onlyoptionalNumber of Logical Drives Configured on this Adapter.
1.3.6.1.4.1.3582.1.1.1.1.3ColumnfirmwareVersionread-onlyoptionalThe Firmware Version of the Firmware running on this Adapter.
1.3.6.1.4.1.3582.1.1.1.1.4ColumnbiosVersionread-onlyoptionalThe Bios Version of the BIOS Present in the Flash ROM on this Adapter.
1.3.6.1.4.1.3582.1.1.1.1.5ColumndramSizeInMBread-onlyoptionalAmount of DRAM in Mega Bytes present on this Adapter.
1.3.6.1.4.1.3582.1.1.1.1.6ColumnrebuildRateInPercentread-writeoptionalRebuild Rate for this Adapter. This determines the Priority of Rebuild/Check-Consistency/Reconstruct Operations versus the Read-Write Operations.
1.3.6.1.4.1.3582.1.1.1.1.7ColumnflushIntervalread-writeoptionalInternal Cache Flush Interval for Logical Drives in WriteBack Mode.
1.3.6.1.4.1.3582.1.1.1.1.8ColumnmaxConcurrentCmdsread-onlyoptionalMaximum Concurrent Commands Supported by the Adapter.
1.3.6.1.4.1.3582.1.1.1.1.9ColumnspinupDelayread-onlyoptionalThis is the Spinup Delay for Spinning Up Physical Drives at Firmware Initialization Time. The Physical Drives are divided into Groups, each containing the numb…
1.3.6.1.4.1.3582.1.1.1.1.10ColumnspinupCountread-onlyoptionalThis is the Spinup Count for Spinning up Physical Drives at Firmware Initialization Time. The Physical Drives are divided into Groups, each containing the numb…
1.3.6.1.4.1.3582.1.1.1.1.11ColumnadpIOReadsPerSecread-onlyoptionalNumber of IO Reads/sec statistics for this adapter.
1.3.6.1.4.1.3582.1.1.1.1.12ColumnadpIOWritesPerSecread-onlyoptionalNumber of IO Writes/sec statistics for this adapter.
1.3.6.1.4.1.3582.1.1.1.1.13ColumnadpReadKBsPerSecread-onlyoptionalAmount of Data Transferred in KBs/sec due to READ Transfers.
1.3.6.1.4.1.3582.1.1.1.1.14ColumnadpWriteKBsPerSecread-onlyoptionalAmount of Data Transferred in KBs/sec due to WRITE Transfers.
1.3.6.1.4.1.3582.1.1.1.1.15ColumnadpReadFailuresPerSecread-onlyoptionalNumber of Read-Failures/sec statistics for this adapter.
1.3.6.1.4.1.3582.1.1.1.1.16ColumnadpWriteFailuresPerSecread-onlyoptionalNumber of Write-Failures/sec statistics for this adapter.
1.3.6.1.4.1.3582.1.1.1.1.17ColumnscanChannelsread-writeoptionalUse this Variable to Discover the Non-Disk Devices attached to the Adapter. Set this Variable to startscan (an integer value of 2) to start the Channel Scannin…
1.3.6.1.4.1.3582.1.1.1.1.18ColumnadpBasePortread-onlyoptionalMaximum Concurrent Commands Supported by the Adapter.
1.3.6.1.4.1.3582.1.1.1.1.19ColumnnumSCSIChannelsread-onlyoptionalMaximum number of SCSI Channels Supported by the Adapter.
1.3.6.1.4.1.3582.1.1.1.1.20ColumnnumFCLoopsread-onlyoptionalNumber of Fibre channel loops Supported by the Adapter.
1.3.6.1.4.1.3582.1.1.1.1.21ColumnsubSystemIDread-onlyoptionalThe PCI sub system ID of this controller
1.3.6.1.4.1.3582.1.1.1.1.22ColumnsubSystemVendorIDread-onlyoptionalThe PCI sub system vendor ID of this controller
1.3.6.1.4.1.3582.1.1.1.1.23ColumnproductNameread-onlyoptionalThe enriched formation of the controller retrieved from the firmware
1.3.6.1.4.1.3582.1.1.1.1.24ColumnadpSpeedread-onlyoptionalMaximum transfer speed of the adapter.
1.3.6.1.4.1.3582.1.1.2TablelogicaldriveTablenot-accessibleoptionalA List of Logical Drive Entries containing Information/Properties about the Logical Drives Configured in the System.
1.3.6.1.4.1.3582.1.1.2.1RowlogicaldriveEntrynot-accessibleoptionalAn Entry in the Logical Drive Table.
1.3.6.1.4.1.3582.1.1.2.1.1ColumnldAdapterNumberread-onlyoptionalThe Adapter Number for this Instance of Adapter/LogicalDrive object.
1.3.6.1.4.1.3582.1.1.2.1.2ColumnlogicalDriveNumberread-onlyoptionalLogical Drive Number for this Logical Drive Entry.
1.3.6.1.4.1.3582.1.1.2.1.3Columnstatusread-writeoptionalThe Status of this Logical Drive.
1.3.6.1.4.1.3582.1.1.2.1.4ColumnsizeInMBread-onlyoptionalThe Configured Size of this Logical Drive.
1.3.6.1.4.1.3582.1.1.2.1.5ColumnraidLevelread-onlyoptionalConfigured Raid Level for this Logical Drive.
1.3.6.1.4.1.3582.1.1.2.1.6ColumnstripeSizeread-onlyoptionalConfigured Stripe Size for this Logical Drive.
1.3.6.1.4.1.3582.1.1.2.1.7ColumnreadPolicyread-writeoptionalConfigured Read Policy for this Logical Drive.
1.3.6.1.4.1.3582.1.1.2.1.8ColumnwritePolicyread-writeoptionalConfigured Write Policy for this Logical Drive.
1.3.6.1.4.1.3582.1.1.2.1.9ColumncachePolicyread-writeoptionalConfigured Cache Policy for this Logical Drive.
1.3.6.1.4.1.3582.1.1.2.1.10ColumnenquiryStringread-onlyoptionalSCSI Inquiry String for this Logical Drive.
1.3.6.1.4.1.3582.1.1.2.1.11ColumnnumberOfSpansread-onlyoptionalNumber of Arrays across which this Logical Drive is Spanning.
1.3.6.1.4.1.3582.1.1.2.1.12ColumnnumberOfStripesread-onlyoptionalConfigured Number of Stripes for this Logical Drive.
1.3.6.1.4.1.3582.1.1.2.1.13ColumncheckConsistencyOrInitializeProgressread-onlyoptionalCheck Consistency or Initialize Progress for this Logical Drive if the Logical Drive Status is checkconsistencyinprogress or initializeinprogress.
1.3.6.1.4.1.3582.1.1.2.1.14ColumnldIOReadsPerSecread-onlyoptionalNumber of IO Reads/sec Statistics for this Logical Drive.
1.3.6.1.4.1.3582.1.1.2.1.15ColumnldIOWritesPerSecread-onlyoptionalNumber of IO Writes/sec Statistics for this Logical Drive.
1.3.6.1.4.1.3582.1.1.2.1.16ColumnldReadKBsPerSecread-onlyoptionalAmount of Data Transferred in KBs/sec due to READ Transfers.
1.3.6.1.4.1.3582.1.1.2.1.17ColumnldWriteKBsPerSecread-onlyoptionalAmount of Data Transferred in KBs/sec due to WRITE Transfers.
1.3.6.1.4.1.3582.1.1.2.1.18ColumnldReadFailuresPerSecread-onlyoptionalNumber of Read-Failures/sec Statistics for this Logical Drive.
1.3.6.1.4.1.3582.1.1.2.1.19ColumnldWriteFailuresPerSecread-onlyoptionalNumber of Write-Failures/sec Statistics for this Logical Drive.
1.3.6.1.4.1.3582.1.1.3TablephysicaldriveTablenot-accessibleoptionalA List of Physical Device Entries containing Information about the Physical Devices in the System.
1.3.6.1.4.1.3582.1.1.3.1RowphysicaldriveEntrynot-accessibleoptionalAn Entry in the Physical Drive Table.
1.3.6.1.4.1.3582.1.1.3.1.1ColumnphysAdapterNumberread-onlyoptionalThe Adapter Number for this Instance of Adapter/Physical-Drive Instance.
1.3.6.1.4.1.3582.1.1.3.1.2ColumnphysChannelread-onlyoptionalChannel Number at Which this Physical Drive is Present.
1.3.6.1.4.1.3582.1.1.3.1.3ColumntargetIDread-onlyoptionalSCSI Target ID at Which This Physical Drive is Present.
1.3.6.1.4.1.3582.1.1.3.1.4Columnstateread-writeoptionalCurrent State of this Physical Drive.
1.3.6.1.4.1.3582.1.1.3.1.5ColumnarrayPositionread-onlyoptionalArray is a group of Physical Drives used to Configure Logical Drives. This String Variable has values of the type Ai-j. Example: A1-2 implies that this drive i…
1.3.6.1.4.1.3582.1.1.3.1.6ColumnsizeMBread-onlyoptionalActual Size of this Physical Drive.
1.3.6.1.4.1.3582.1.1.3.1.7ColumndeviceTyperead-onlyoptionalDevice Type of this Physical Drive.
1.3.6.1.4.1.3582.1.1.3.1.8ColumninquiryStringread-onlyoptionalSCSI Inquiry String for this Device.
1.3.6.1.4.1.3582.1.1.3.1.9ColumnscsiLevelread-onlyoptionalANSI SCSI Level Conformance of this Device.
1.3.6.1.4.1.3582.1.1.3.1.10ColumnmaximumQueueDepthread-onlyoptionalThe maximum queue depth of this Device.
1.3.6.1.4.1.3582.1.1.3.1.11ColumnrebuildProgressread-onlyoptionalRebuild Progress for this Physical Drive if the Physical Drive State is Rebuild.
1.3.6.1.4.1.3582.1.1.3.1.12ColumnmediumErrorsread-onlyoptionalMedium Errors Occurred on this Drive Since it was Configured.
1.3.6.1.4.1.3582.1.1.3.1.13ColumnphysSlotStatusread-onlyoptionalIndicates the status of interest on the drive slot
1.3.6.1.4.1.3582.1.1.3.1.14ColumnphysSlotNumberread-onlyoptionalSCSI Target Slot Number at Which This Physical Drive is Present.
1.3.6.1.4.1.3582.1.1.3.1.15ColumnotherErrorsread-onlyoptionalOther Errors Occurred on this Drive Since it was Configured.
1.3.6.1.4.1.3582.1.1.3.1.16ColumnphysTerminationread-onlyoptionalNegotiation Information of the physical drive. This field is applicable only to drives.
1.3.6.1.4.1.3582.1.1.3.1.17ColumnphysSpeedread-onlyoptionalTransfer speed of the physical drive. This field is applicable only to drives.
1.3.6.1.4.1.3582.1.1.3.1.18ColumnlunNumberread-onlyoptionalSCSI LUN ID of this Physical Device
1.3.6.1.4.1.3582.1.1.4TablechannelTablenot-accessibleoptionalA List of Channel Entries containing Information/Properties about the Channels on the Adapter.
1.3.6.1.4.1.3582.1.1.4.1RowchannelEntrynot-accessibleoptionalAn Entry in the channel table.
1.3.6.1.4.1.3582.1.1.4.1.1ColumnchanAdapterNumberread-onlyoptionalThe Adapter Number for this Instance of Adapter/Channel Instance.
1.3.6.1.4.1.3582.1.1.4.1.2Columnchannelread-onlyoptionalChannel Number for this Channel.
1.3.6.1.4.1.3582.1.1.4.1.3Columnterminationsread-onlyoptionalCurrent Terminations Effective on this Channel
1.3.6.1.4.1.3582.1.1.4.1.4ColumnchannelStatusread-onlyoptionalCurrent Activity Status (QUIET/ACTIVE) for this Channel.
1.3.6.1.4.1.3582.1.1.4.1.5ColumnchannelTyperead-onlymandatoryType of the channel(RAID/SCSI).
1.3.6.1.4.1.3582.1.1.5TablefcDeviceTablenot-accessibleoptionalA List of Entries containing Information about the FC Devices in the System.
1.3.6.1.4.1.3582.1.1.5.1RowfcDeviceEntrynot-accessibleoptionalAn Entry in the FC Device Table.
1.3.6.1.4.1.3582.1.1.5.1.1ColumnfcPhysAdapterNumberread-onlyoptionalThe Adapter Number for this Instance of Adapter/Physical-Drive Instance.
1.3.6.1.4.1.3582.1.1.5.1.2ColumnfcPhysChannelread-onlyoptionalThe Channel Number for this Instance of Adapter/Physical-Drive
1.3.6.1.4.1.3582.1.1.5.1.3ColumnfcTargetIdread-onlyoptionalThe Target Number for this Instance of Adapter/Physical-Drive
1.3.6.1.4.1.3582.1.1.5.1.4ColumnfcLoopID-0read-onlyoptionalLoop ID of this FC Drive.
1.3.6.1.4.1.3582.1.1.5.1.5ColumnfcLoopID-1read-onlyoptionalLoop ID of this FC Drive.
1.3.6.1.4.1.3582.1.1.5.1.6ColumnfcWwnread-onlyoptionalWWN is the World Wide Name of this FC device
1.3.6.1.4.1.3582.1.1.5.1.7ColumnfcStateread-writeoptionalCurrent State of this Physical Drive.
1.3.6.1.4.1.3582.1.1.5.1.8ColumnfcArrayPositionread-onlyoptionalArray is a group of Physical Drives used to Configure Logical Drives. This String Variable has values of the type Ai-j. Example: A1-2 implies that this drive i…
1.3.6.1.4.1.3582.1.1.5.1.9ColumnfcSizeMBread-onlyoptionalActual Size of this Physical Drive.
1.3.6.1.4.1.3582.1.1.5.1.10ColumnfcInquiryStringread-onlyoptionalSCSI Inquiry String for this Device.
1.3.6.1.4.1.3582.1.1.5.1.11ColumnfcScsiLevelread-onlyoptionalANSI SCSI Level Conformance of this Device.
1.3.6.1.4.1.3582.1.1.5.1.12ColumnfcRebuildProgressread-onlyoptionalRebuild Progress for this Physical Drive if the Physical Drive State is Rebuild.
1.3.6.1.4.1.3582.1.1.5.1.13ColumnfcMediumErrorsread-onlyoptionalMedium Errors Occurred on this Drive Since it was Configured.
1.3.6.1.4.1.3582.1.1.5.1.14ColumnfcOtherErrorsread-onlyoptionalOther Errors Occurred on this Drive Since it was Configured.
1.3.6.1.4.1.3582.1.1.6TablefcChannelTablenot-accessibleoptionalA List of FC Channel Entries containing Information about the FC Channels on the Adapter.
1.3.6.1.4.1.3582.1.1.6.1RowfcChannelEntrynot-accessibleoptionalAn Entry in the FC channel table.
1.3.6.1.4.1.3582.1.1.6.1.1ColumnfcChanAdapterNumberread-onlyoptionalThe Adapter Number for this Instance of Adapter/fc-Channel Instance.
1.3.6.1.4.1.3582.1.1.6.1.2ColumnfcChannelread-onlyoptionalThe Channel Number for this Instance
1.3.6.1.4.1.3582.1.1.6.1.3ColumnfcLoopNumberread-onlyoptionalLoop Index for this fcChannel.
1.3.6.1.4.1.3582.1.1.6.1.4ColumnfcLoopStatusread-onlyoptionalCurrent Activity Status (QUIET/ACTIVE) for this fcChannel.
1.3.6.1.4.1.3582.1.1.6.1.5ColumnfcNumberofDevicesread-onlyoptionalThe number of FC devices in this fcChannel
1.3.6.1.4.1.3582.1.1.6.1.6ColumnfcProcessorTyperead-onlyoptionalThe processor type on this fcChannel
1.3.6.1.4.1.3582.1.1.9ScalarioReadsPerSecread-onlyoptionalThe Total IO-Reads/Sec Statistics on all Adapters.
1.3.6.1.4.1.3582.1.1.10ScalarioWritesPerSecread-onlyoptionalThe Total IO-Writes/Sec Statistics on all Adapters.
1.3.6.1.4.1.3582.1.1.11ScalarreadKBsPerSecread-onlyoptionalThe Total Read KBs Per Second Statistics on all Adapters.
1.3.6.1.4.1.3582.1.1.12ScalarwriteKBsPerSecread-onlyoptionalThe Total Write KBs Per Second Statistics on all Adapters.
1.3.6.1.4.1.3582.1.1.13ScalarreadFailuresPerSecread-onlyoptionalThe Total Read Failures Per Second Statistics on all Adapters.
1.3.6.1.4.1.3582.1.1.14ScalarwriteFailuresPerSecread-onlyoptionalThe Total Write Failures Per Second Statistics on all Adapters.
1.3.6.1.4.1.3582.1.1.15TableenclConfigurationTablenot-accessibleoptionalA List of Enclosure Configuration Entries containing Information about the SAF-TE Enclosures in the System.
1.3.6.1.4.1.3582.1.1.15.1RowenclConfigurationEntrynot-accessibleoptionalAn Entry in the Enclosure Configuration Table.
1.3.6.1.4.1.3582.1.1.15.1.1ColumnenclAdapterNumberread-onlyoptionalThe Adapter Number for this Instance of Adapter/Enclosure Instance.
1.3.6.1.4.1.3582.1.1.15.1.2ColumnenclNumberread-onlyoptionalIndicates the enclosure number for this Enclosure. The numbering is w.r.t adapter and not w.r.t Channel
1.3.6.1.4.1.3582.1.1.15.1.3ColumnenclChannelread-onlyoptionalChannel Number at Which this Enclosure is Present.
1.3.6.1.4.1.3582.1.1.15.1.4ColumnenclNumDeviceSlotsread-onlyoptionalTotal number of device slots on the channel for this Enclosure
1.3.6.1.4.1.3582.1.1.15.1.5ColumnenclNumFansread-onlyoptionalTotal number SEP manageable of fans for this Enclosure
1.3.6.1.4.1.3582.1.1.15.1.6ColumnenclNumTempSensorsread-onlyoptionalNumber of SEP manageable Temperature Sensors for this Enclosure
1.3.6.1.4.1.3582.1.1.15.1.7ColumnenclNumPowerSuppliesread-onlyoptionalMaximum number of SEP manageable Power Supplies for this Enclosure
1.3.6.1.4.1.3582.1.1.15.1.8ColumnenclDoorLockStatusread-onlyoptionalIndicates whether this enclosure has door lock installed/locked/unlocked
1.3.6.1.4.1.3582.1.1.15.1.9ColumnenclAudibleAlarmread-onlyoptionalIndicates the availability of Audible Alarm with this Enclosure
1.3.6.1.4.1.3582.1.1.15.1.10ColumnenclAlarmStatusread-onlyoptionalIndicates whether this Enclosure speaker is ON or OFF
1.3.6.1.4.1.3582.1.1.15.1.11ColumnenclTemperatureScaleread-onlyoptionalIndicates whether this Enclosure reports temperature in Celsius or Fahrenheit
1.3.6.1.4.1.3582.1.1.15.1.12ColumnenclTotalPowerOnMinsread-onlyoptionalThis indicates the total time in minutes that the RAID device has been powered ON. It is cumulative over the life of the device
1.3.6.1.4.1.3582.1.1.15.1.13ColumnenclTotalPowerOnCyclesread-onlyoptionalThis indicates the count of number of times that the RAID device has been powered ON. It is cumulative over the life of the device
1.3.6.1.4.1.3582.1.1.16TableenclFanTablenot-accessibleoptionalA List of SAF-TE Enclosure Fan Entries
1.3.6.1.4.1.3582.1.1.16.1RowenclFanEntrynot-accessibleoptionalAn Entry in the Enclosure Fan Table.
1.3.6.1.4.1.3582.1.1.16.1.1ColumnenclNumberFanread-onlyoptionalEnclosure Number at Which this Enclosure with the Fan is Present.
1.3.6.1.4.1.3582.1.1.16.1.2ColumnenclFanIndexread-onlyoptionalThe instance of the fan in the enclosure for the adapter/channel
1.3.6.1.4.1.3582.1.1.16.1.3ColumnenclFanStatusread-onlyoptionalThe Status of this fan
1.3.6.1.4.1.3582.1.1.17TableenclPowerSupplyTablenot-accessibleoptionalA List of SAF-TE Enclosure Power Supply Entries
1.3.6.1.4.1.3582.1.1.17.1RowenclPowerSupplyEntrynot-accessibleoptionalAn Entry in the Enclosure Power Supply Table.
1.3.6.1.4.1.3582.1.1.17.1.1ColumnenclNumberPowerread-onlyoptionalenclosure number at Which this Enclosure with the Power Supply is Present.
1.3.6.1.4.1.3582.1.1.17.1.2ColumnenclPowerSupplyIndexread-onlyoptionalThe instance of the PowerSupply in the enclosure for the adapter/channel
1.3.6.1.4.1.3582.1.1.17.1.3ColumnenclPowerSupplyStatusread-onlyoptionalThe Status of this PowerSupply
1.3.6.1.4.1.3582.1.1.18TableenclTempSensorsTablenot-accessibleoptionalA List of SAF-TE Enclosure Temperature Sensor Entries
1.3.6.1.4.1.3582.1.1.18.1RowenclTempSensorsEntrynot-accessibleoptionalAn Entry in the Enclosure Temperature Sensor Table.
1.3.6.1.4.1.3582.1.1.18.1.1ColumnenclNumberTempread-onlyoptionalenclosure number at Which this Enclosure with the temperature sensor is Present.
1.3.6.1.4.1.3582.1.1.18.1.2ColumnenclTempSensorIndexread-onlyoptionalThe instance of the temperature sensor indices in the enclosure for the adapter/channel
1.3.6.1.4.1.3582.1.1.18.1.3ColumnenclTemperatureread-onlyoptionalIndicates the temperature reported by the sensor in degree Fahrenheit
1.3.6.1.4.1.3582.1.1.200NoderaidTraps
1.3.6.1.4.1.3582.1.1.200.1001ScalarrtAdapterNumberread-onlyoptionalAdapter Number for which Trap is generated.
1.3.6.1.4.1.3582.1.1.200.1002ScalarrtLogicalDriveNumberread-onlyoptionalLogical Drive Number for which Trap is generated.
1.3.6.1.4.1.3582.1.1.200.1003ScalarrtChannelNumberread-onlyoptionalChannel Number on the Adapter for which Trap is Generated.
1.3.6.1.4.1.3582.1.1.200.1004ScalarrtTargetIDread-onlyoptionalDevice ID of the Physical Drive for which Trap is Generated.
1.3.6.1.4.1.3582.1.1.200.1005ScalarrtOldDriveStateread-onlyoptionalOld State of Logical/Physical Drive, when a State Change Trap is Generated.
1.3.6.1.4.1.3582.1.1.200.1006ScalarrtNewDriveStateread-onlyoptionalNew State of Logical/Physical Drive, when a State Change Trap is Generated.
1.3.6.1.4.1.3582.1.1.200.1007ScalarrtSenseKeyread-onlyoptionalCheck Condition Sense-Key reported by Physical Drive for which Trap is Generated.
1.3.6.1.4.1.3582.1.1.200.1008ScalarrtASCread-onlyoptionalCheck Condition Additional Sense Code (ASC) reported by Physical Drive for which Trap is Generated.
1.3.6.1.4.1.3582.1.1.200.1009ScalarrtASCQread-onlyoptionalCheck Condition Additional Sense Code Qualifier (ASCQ) reported by Physical Drive for which Trap is Generated.
1.3.6.1.4.1.3582.1.1.200.1010ScalarrtDriveVendorread-onlyoptionalVendor Identification String from the SCSI Inquiry Data for the Drive.
1.3.6.1.4.1.3582.1.1.200.1011ScalarrtEnclNumberread-onlyoptionalEnclosure Number reported by the RAID Controller.
1.3.6.1.4.1.3582.1.1.200.1012ScalarrtEnclTempSensorIndexread-onlyoptionalEnclosure Temperature Sensor Number reported by the SEP device
1.3.6.1.4.1.3582.1.1.200.1013ScalarrtEnclTemperatureread-onlyoptionalEnclosure Temperature in Fahrenheit reported by the SEP device
1.3.6.1.4.1.3582.1.1.200.1014ScalarrtEnclFanIndexread-onlyoptionalEnclosure Fan Number reported by the SEP device
1.3.6.1.4.1.3582.1.1.200.1015ScalarrtEnclPowerSupplyIndexread-onlyoptionalEnclosure Power Supply Number reported by the SEP device
1.3.6.1.4.1.3582.1.1.200.1016ScalarrtWWNread-onlyoptionalThe World Wide Name of the FC device whose loop ID or State changes
1.3.6.1.4.1.3582.1.1.200.1017ScalarrtOldLoopIDread-onlyoptionalIndex of the loop before its state changed
1.3.6.1.4.1.3582.1.1.200.1018ScalarrtNewLoopIDread-onlyoptionalIndex of the loop after its state changed
1.3.6.1.4.1.3582.1.1.200.9001NodertConfigUpdatedAdapter-%d: A New Configuration has been written.
1.3.6.1.4.1.3582.1.1.200.9002NodertPhysicalDriveStateChangeAdapter-%d, Channel-%d, Target-%d: Drive State Changed from %s to %s.
1.3.6.1.4.1.3582.1.1.200.9003NodertLogicalDriveStateChangeAdapter-%d, Logical Drive-%d: State Changed from %s to %s.
1.3.6.1.4.1.3582.1.1.200.9004NodertInitializeStartedAdapter-%d, Logical Drive-%d: Initialization Started.
1.3.6.1.4.1.3582.1.1.200.9005NodertInitializeCompletedAdapter-%d, Logical Drive-%d: Initialization Completed Successfully.
1.3.6.1.4.1.3582.1.1.200.9006NodertInitializeAbortedAdapter-%d, Logical Drive-%d: Initialization Aborted by User.
1.3.6.1.4.1.3582.1.1.200.9007NodertInitializeFailedAdapter-%d, Logical Drive-%d: Initialization Failed.
1.3.6.1.4.1.3582.1.1.200.9008NodertCheckConsistencyStartedAdapter-%d, Logical Drive-%d: Check Consistency Started.
1.3.6.1.4.1.3582.1.1.200.9009NodertCheckConsistencyCompletedAdapter-%d, Logical Drive-%d: Check Consistency Completed. No Inconsistencies Found.
1.3.6.1.4.1.3582.1.1.200.9010NodertCheckConsistencyAbortedAdapter-%d, Logical Drive-%d: Check Consistency Aborted by User.
1.3.6.1.4.1.3582.1.1.200.9011NodertConsistencyCorrectedAdapter-%d, Logical Drive-%d: Check Consistency Operation Completed. Inconsistencies have been Cured.
1.3.6.1.4.1.3582.1.1.200.9012NodertCheckConsistencyFailedAdapter-%d, Logical Drive-%d: Check Consistency Failed.
1.3.6.1.4.1.3582.1.1.200.9013NodertReconstructionStartedAdapter-%d, Logical Drive-%d: Reconstruction Started.
1.3.6.1.4.1.3582.1.1.200.9014NodertReconstructionCompletedAdapter-%d, Logical Drive-%d: Reconstruction Completed Successfully.
1.3.6.1.4.1.3582.1.1.200.9015NodertReconstructionFailedAdapter-%d, Logical Drive-%d: Reconstruction Failed.
1.3.6.1.4.1.3582.1.1.200.9016NodertPredictiveFailuresExceededAdapter-%d, Channel-%d, Target-%d: Reported Predictive Failure. Drive Identification String = %s Sense Key = 0x%x, ASC = 0x%x, ASCQ = 0x%x.
1.3.6.1.4.1.3582.1.1.200.9017NodertPredictiveFailuresFalseAdapter-%d, Channel-%d, Target-%d: Reported Failure Prediction Threshold Exceeded [FALSE]. Drive Identification String = %s Sense Key = 0x%x, ASC = 0x%x, ASCQ …
1.3.6.1.4.1.3582.1.1.200.9018NodertCheckConditionStatusAdapter-%d, Channel-%d, Target-%d: Command Completed with Sense-Key-0x%x ASC-0x%x ASCQ-0x%x.
1.3.6.1.4.1.3582.1.1.200.9019NodertNewDriveInsertedAdapter-%d, Channel-%d, Target-%d: New Device Inserted.
1.3.6.1.4.1.3582.1.1.200.9020NodertBatteryMissingAdapter-%d: Battery Module is missing.
1.3.6.1.4.1.3582.1.1.200.9021NodertBatteryVolatageLowAdapter-%d: Battery Module Voltage is Low.
1.3.6.1.4.1.3582.1.1.200.9022NodertBatteryTemperatureHighAdapter-%d: Battery Module Temperature Exceeded Danger Threshold.
1.3.6.1.4.1.3582.1.1.200.9023NodertPhysicalDriveStateReadyAdapter-%d, Channel-%d, Target-%d: Drive State Changed from %s to %s.
1.3.6.1.4.1.3582.1.1.200.9024NodertPhysicalDriveStateOnlineAdapter-%d, Channel-%d, Target-%d: Drive State Changed from %s to %s.
1.3.6.1.4.1.3582.1.1.200.9025NodertPhysicalDriveStateFailedAdapter-%d, Channel-%d, Target-%d: Drive State Changed from %s to %s.
1.3.6.1.4.1.3582.1.1.200.9026NodertPhysicalDriveStateRebuildAdapter-%d, Channel-%d, Target-%d: Drive State Changed from %s to %s.
1.3.6.1.4.1.3582.1.1.200.9027NodertPhysicalDriveStateHotspareAdapter-%d, Channel-%d, Target-%d: Drive State Changed from %s to %s.
1.3.6.1.4.1.3582.1.1.200.9028NodertLogicalDriveStateOfflineAdapter-%d, Logical Drive-%d: State Changed from %s to %s.
1.3.6.1.4.1.3582.1.1.200.9029NodertLogicalDriveStateDegradedAdapter-%d, Logical Drive-%d: State Changed from %s to %s.
1.3.6.1.4.1.3582.1.1.200.9030NodertLogicalDriveStateOptimalAdapter-%d, Logical Drive-%d: State Changed from %s to %s.
1.3.6.1.4.1.3582.1.1.200.9031NodertLogicalDriveStateInitializeAdapter-%d, Logical Drive-%d: State Changed from %s to %s.
1.3.6.1.4.1.3582.1.1.200.9032NodertLogicalDriveStateChkConsistAdapter-%d, Logical Drive-%d: State Changed from %s to %s.
1.3.6.1.4.1.3582.1.1.200.9033NodertEnclTemperatureOutofRangeAdapter-%d, Channel-%d, Enclosure-%d, Temperature Sensor -%d: Temperature %d is out of Range
1.3.6.1.4.1.3582.1.1.200.9034NodertEnclTemperatureNormalAdapter-%d, Channel-%d, Enclosure-%d, Temperature Sensor -%d: Temperature %d is Normal
1.3.6.1.4.1.3582.1.1.200.9035NodertEnclFanMalfunctionAdapter-%d, Channel-%d, Enclosure-%d, Fan-%d: Fan is Malfunctioning
1.3.6.1.4.1.3582.1.1.200.9036NodertEnclFanOkAdapter-%d, Channel-%d, Enclosure-%d, Fan-%d: Fan is operating properly
1.3.6.1.4.1.3582.1.1.200.9037NodertEnclPowerSupplyMalfunctionAdapter-%d, Channel-%d, Enclosure-%d, Power Supply-%d: Power Supply is Malfunctioning
1.3.6.1.4.1.3582.1.1.200.9038NodertEnclPowerSupplyOkAdapter-%d, Channel-%d, Enclosure-%d, Power Supply-%d: Power Supply is operating properly
1.3.6.1.4.1.3582.1.1.200.9040NodertFCLooplStateChangeAdapter-%d, LoopId-%d: Loop State Changed from %s to %s.