MIB Viewer

RAIDMANAGER-MIB

82 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.36Nodedec
1.3.6.1.4.1.36.2Nodeema
1.3.6.1.4.1.36.2.15Nodesysobjids
1.3.6.1.4.1.36.2.15.21Noderaidmanager
1.3.6.1.4.1.36.2.15.21.1Nodeagent
1.3.6.1.4.1.36.2.15.21.1NodediskFailureTrapA disk drive has failed. Details: A disk device has failed. User Action: Replace the disk device.
1.3.6.1.4.1.36.2.15.21.1.1ScalaragManufacturerread-onlymandatoryThe name of the Enterprise Storage Manager Agent manufacturer.
1.3.6.1.4.1.36.2.15.21.1.2ScalaragMajVersionread-onlymandatoryEnterprise Storage Manager Agent Major Version Number (e.g., 3 for 3.0).
1.3.6.1.4.1.36.2.15.21.1.3ScalaragMinVersionread-onlymandatoryEnterprise Storage Manager Agent Minor Version Number (e.g., 0 for 3.0).
1.3.6.1.4.1.36.2.15.21.1.4ScalaragHostNameread-onlymandatoryThe Host System Network Name where the agent resides.
1.3.6.1.4.1.36.2.15.21.1.5ScalaragEnterpriseread-onlymandatoryThe Enterprise ID subtree for Enterprise Storage Manager Agent MIB is registered.
1.3.6.1.4.1.36.2.15.21.1.6ScalaragDescriptionread-onlymandatoryThe Enterprise Array Storage Agent description.
1.3.6.1.4.1.36.2.15.21.2NodediskInformationTrapA disk drive has recovered. Details: A disk device has recovered. User Action: None.
1.3.6.1.4.1.36.2.15.21.2Nodeworkstation
1.3.6.1.4.1.36.2.15.21.2.1ScalarwsCPUread-onlymandatoryThe workstation CPU type (e.g., 80486).
1.3.6.1.4.1.36.2.15.21.2.2ScalarwsComputerTyperead-onlymandatoryThe workstation Computer type (e.g., PC/AT).
1.3.6.1.4.1.36.2.15.21.2.3ScalarwsModelread-onlymandatoryThe workstation model number.
1.3.6.1.4.1.36.2.15.21.2.4ScalarwsSubModelread-onlymandatoryThe workstation submodel number.
1.3.6.1.4.1.36.2.15.21.2.5ScalarwsBiosVersionread-onlymandatoryThe workstation BIOS Version.
1.3.6.1.4.1.36.2.15.21.2.6ScalarwsOSread-onlymandatoryThe workstation operating system name (e.g., WINNT).
1.3.6.1.4.1.36.2.15.21.2.7ScalarwsOSMajVersionread-onlymandatoryThe workstation OS major version number (e.g., 3 for WINNT 3.51).
1.3.6.1.4.1.36.2.15.21.2.8ScalarwsOSMinVersionread-onlymandatoryThe workstation OS minor version number (e.g., 51 for WINNT 3.51).
1.3.6.1.4.1.36.2.15.21.3NodepowerSupplyFailureTrapOne power supply has failed. Details: The power supply in the specified location has failed. User Action: Replace power supply.
1.3.6.1.4.1.36.2.15.21.3Nodesubsys
1.3.6.1.4.1.36.2.15.21.3.1ScalarssTotalSubSystemsread-onlymandatoryThe total number of subsystems presently serviced by this agent.
1.3.6.1.4.1.36.2.15.21.3.2TablessStatusTablenot-accessiblemandatoryThis table holds the status information for each subsystem.
1.3.6.1.4.1.36.2.15.21.3.2.1RowssEntrynot-accessiblemandatoryThe subsystem information entry.
1.3.6.1.4.1.36.2.15.21.3.2.1.1ColumnssEntryIndexread-onlymandatoryThe index into ssStatusTable .
1.3.6.1.4.1.36.2.15.21.3.2.1.2ColumnssSubsysNameread-onlymandatoryThe local Subsystem Name.
1.3.6.1.4.1.36.2.15.21.3.2.1.3ColumnssOverallStatusread-onlymandatoryThis variable reports the overall status of the storage subsystem. GREEN: Normal Operating Condition YELLOW: Warning Condition RED: Subsystem Communication Fai…
1.3.6.1.4.1.36.2.15.21.3.2.1.4ColumnssDiskStatusread-onlymandatoryThis variable reports the overall status for the physical devices in the subsystem.
1.3.6.1.4.1.36.2.15.21.3.2.1.5ColumnssPowerStatusread-onlymandatoryThis variable reports the status for the Power Supply system in the subsystem.
1.3.6.1.4.1.36.2.15.21.3.2.1.6ColumnssFanStatusread-onlymandatoryThis variable reports the status for the FAN system in the subsystem.
1.3.6.1.4.1.36.2.15.21.3.2.1.7ColumnssCacheBatteryStatusread-onlymandatoryThis variable reports the status for the Cache Battery in the subsystem. This status object is currently non-functional but in place for future use.
1.3.6.1.4.1.36.2.15.21.3.2.1.8ColumnssTemperatureStatusread-onlymandatoryThis variable reports the status for the Temperature in the subsystem.
1.3.6.1.4.1.36.2.15.21.3.2.1.9ColumnssCommStatusread-onlymandatoryThis variable reports the status for the communication to the Primary Controller.
1.3.6.1.4.1.36.2.15.21.3.2.1.10ColumnssEmuExtInputStatusread-onlymandatoryThis variable reports the status for the EMU external input.
1.3.6.1.4.1.36.2.15.21.3.2.1.11ColumnssEmuPresentread-onlymandatoryThis variable reports the availability of the Environment Monitoring Unit for the storage subsystem.
1.3.6.1.4.1.36.2.15.21.3.2.1.12ColumnssController1Statusread-onlymandatoryThis variable reports the status for the Primary Controller.
1.3.6.1.4.1.36.2.15.21.3.2.1.13ColumnssController1SerNumread-onlymandatoryThe Primary Controller's Serial Number.
1.3.6.1.4.1.36.2.15.21.3.2.1.14ColumnssController1RDACread-onlymandatoryThe Primary Controller MODE.
1.3.6.1.4.1.36.2.15.21.3.2.1.15ColumnssController1Typeread-onlymandatoryThe Primary Controller's Type indicator.
1.3.6.1.4.1.36.2.15.21.3.2.1.16ColumnssController1ProdIDread-onlymandatoryThe Primary Controller's Product ID.
1.3.6.1.4.1.36.2.15.21.3.2.1.17ColumnssController1FwRevread-onlymandatoryThe Primary Controller's Firmware Revision.
1.3.6.1.4.1.36.2.15.21.3.2.1.18ColumnssController1HwRevread-onlymandatoryThe Primary Controller's Hardware Revision.
1.3.6.1.4.1.36.2.15.21.3.2.1.19ColumnssController2Statusread-onlymandatoryThis variable reports the status for the Secondary Controller.
1.3.6.1.4.1.36.2.15.21.3.2.1.20ColumnssController2SerNumread-onlymandatoryThe Secondary Controller's Serial Number.
1.3.6.1.4.1.36.2.15.21.3.2.1.21ColumnssController2RDACread-onlymandatoryThe Secondary Controller MODE.
1.3.6.1.4.1.36.2.15.21.3.2.1.22ColumnssController2Typeread-onlymandatoryThe Secondary Controller's Type indicator.
1.3.6.1.4.1.36.2.15.21.3.2.1.23ColumnssController2ProdIDread-onlymandatoryThe Secondary Controller's Product ID.
1.3.6.1.4.1.36.2.15.21.3.2.1.24ColumnssController2FwRevread-onlymandatoryThe Secondary Controller's Firmware Revision.
1.3.6.1.4.1.36.2.15.21.3.2.1.25ColumnssController2HwRevread-onlymandatoryThe Secondary Controller's Hardware Revision.
1.3.6.1.4.1.36.2.15.21.3.2.1.26ColumnssUpsStatusread-onlymandatoryUninterruptable Power Supply status (Currently for future use).
1.3.6.1.4.1.36.2.15.21.3.2.1.27ColumnssLunStatusread-onlymandatoryLUN status.
1.3.6.1.4.1.36.2.15.21.3.2.1.28ColumnssDiskNameread-onlymandatoryThe name of disk with state change.
1.3.6.1.4.1.36.2.15.21.3.2.1.29ColumnssPowerSupplyLocationread-onlymandatoryThe location of power supply with state change.
1.3.6.1.4.1.36.2.15.21.3.2.1.30ColumnssFanLocationread-onlymandatoryThe location of fan with state change.
1.3.6.1.4.1.36.2.15.21.3.2.1.31ColumnssCacheBatteryLocationread-onlymandatoryThe location of controller cache battery with state change.
1.3.6.1.4.1.36.2.15.21.3.2.1.32ColumnssTemperatureSensorLocationread-onlymandatoryThe location of temperature sensor with state change.
1.3.6.1.4.1.36.2.15.21.3.2.1.33ColumnssCabinetNumberread-onlymandatoryThe current cabinet number which has FRU state change.
1.3.6.1.4.1.36.2.15.21.3.2.1.34ColumnssLunNameread-onlymandatoryThe name of the LUN with a state change.
1.3.6.1.4.1.36.2.15.21.3.2.1.35ColumnssDiskPortread-onlymandatoryThe current disk channel number.
1.3.6.1.4.1.36.2.15.21.3.2.1.36ColumnssDiskTargetread-onlymandatoryThe current disk SCSI Target ID.
1.3.6.1.4.1.36.2.15.21.4NodepowerSupplyInformationTrapPower supply has recovered. Details: The power supply in the specified location has gone from BAD to good. User Action: None.
1.3.6.1.4.1.36.2.15.21.5NodefanFailureTrapA fan has failed. Details: The fan in the specified location has failed. User Action: Replace fan.
1.3.6.1.4.1.36.2.15.21.6NodefanInformationTrapA fan has recovered. Details: The fan in the specified location has recovered. User Action: None.
1.3.6.1.4.1.36.2.15.21.7NodecacheBatteryFailureTrapA controller cache battery has failed. Details: The cache battery in specified location has failed. User Action: Replace cache battery or replenish charge.
1.3.6.1.4.1.36.2.15.21.8NodecacheBatteryLowTrapA controller cache battery has LOW state. Details: The cache battery in specified location has LOW state. User Action: Replace cache battery or replenish charg…
1.3.6.1.4.1.36.2.15.21.9NodecacheBatteryInformationTrapA controller cache battery has good state. Details: The cache battery in specified location has good state. User Action: None.
1.3.6.1.4.1.36.2.15.21.10NodetemperatureOverThresholdTrapA temperature sensor has exceeded WARNING threshold limit. Details: The temperature sensor in the specified location has exceeded WARNING threshold limit. User…
1.3.6.1.4.1.36.2.15.21.11NodetemperatureInformationTrapA temperature sensor indicates temperature below WARNING threshold limit. Details: The temperature sensor in the specified location indicates below WARNING thr…
1.3.6.1.4.1.36.2.15.21.12NodecommunicationFailureTrapCommunication with the subsystem has failed. Details: The Agent lost communication with subsystem. User Action: Possible causes are data path interruption, com…
1.3.6.1.4.1.36.2.15.21.13NodecommunicationInformationTrapCommunication with the subsystem has recovered. Details: The Agent recovered communication with subsystem. User Action: None.
1.3.6.1.4.1.36.2.15.21.14NodecontrollerFailureTrapThe Secondary Controller in the subsytem has failed. Details: The Secondary Controller has failed. User Action: Replace controller. Possible causes are PCMCIA …
1.3.6.1.4.1.36.2.15.21.15NodecontrollerInformationTrapThe Secondary Controller in the subsytem has recovered. Details: The Secondary Controller has recovered. User Action: None.
1.3.6.1.4.1.36.2.15.21.16NodelunFailureTrapA LUN has failed. Details: The LUN has failed and is off-line. User Action: Possible cause is too many failed disk drives that make up the LUN, the OS can no l…
1.3.6.1.4.1.36.2.15.21.17NodelunReconstructTrapA LUN has started the reconstruction process. Details: The LUN has started the reconstruction process but is available for normal use. Possible causes are an a…
1.3.6.1.4.1.36.2.15.21.18NodelunReducedTrapA LUN has become degraded. Details: A LUN has become degraded due to a member disk device failure. User Action: Replace the failed disk device; add a spare to …
1.3.6.1.4.1.36.2.15.21.19NodelunInformationTrapA LUN has become optimal. Details: A LUN has become optimal due to a successful completion of the reconstruction process. User Action: None.
1.3.6.1.4.1.36.2.15.21.20NodeexternalInputFailureTrapThe user-defined External Input to the EMU indicates a failure. Details: The External Input to the EMU indicates a failure. User Action: If the state of the is…
1.3.6.1.4.1.36.2.15.21.21NodeexternalInputInformationTrapThe user-defined External Input to the EMU indicates a recovery. Details: The External Input to the EMU indicates a recovery. User Action: None.
1.3.6.1.4.1.36.2.15.21.22NodecacheBatteryStateUnknownTrapA controller cache battery has unknown state. Details: The cache battery in specified location has an unknown state. User Action: None.