MIB Viewer

RAISECOM-ALARM-MGMT-MIB

20 objects
This MIB module contains managed object definitions for MPLS.
OIDNameAccessStatusDescription
1.3.6.1.4.1.8886.1.34IdentityraisecomAlarmMgmtThis MIB module contains managed object definitions for MPLS.
1.3.6.1.4.1.8886.1.34.1NoderaisecomAlarmMgmtObejcts
1.3.6.1.4.1.8886.1.34.1.1ScalarraisecomAlarmMgmtRaiseDelayread-writecurrentThe approximate period from the time a alarm was raised to a time this alarm was reported.
1.3.6.1.4.1.8886.1.34.1.2ScalarraisecomAlarmMgmtClearDelayread-writecurrentThe approximate period from the time a alarm was cleared to a time this alarm report.
1.3.6.1.4.1.8886.1.34.1.3ScalarraisecomAlarmMgmtActiveStoreModeread-writecurrentThe storage mode of the alarm active table
1.3.6.1.4.1.8886.1.34.1.4ScalarraisecomAlarmMgmtInhibitEnableread-writecurrentEnable or Disable Alarm Inhibit
1.3.6.1.4.1.8886.1.34.1.5ScalarraisecomAlarmMgmtSyslogEnableread-writecurrentEnable or Disable write syslog when an alarm raise
1.3.6.1.4.1.8886.1.34.1.6ScalarraisecomAlarmMgmtActiveClearread-writecurrentclear active alarm according to the active table third index
1.3.6.1.4.1.8886.1.34.1.7TableraisecomAlarmMgmtConfigTablenot-accessiblecurrentThis table specifies the information of alarm configuration.
1.3.6.1.4.1.8886.1.34.1.7.1RowraisecomAlarmMgmtConfigEntrynot-accessiblecurrentA row in this table represents the configuration of specified alarm.
1.3.6.1.4.1.8886.1.34.1.7.1.1ColumnraisecomAlarmMgmtIdnot-accessiblecurrentFirst index of alarm config table which is equal to alarm group Id
1.3.6.1.4.1.8886.1.34.1.7.1.2ColumnraisecomAlarmMgmtClearread-writecurrentThe swith of alarm clear,when open the swith the related active alarm entry will be deleted from alarm active table
1.3.6.1.4.1.8886.1.34.1.7.1.3ColumnraisecomAlarmMgmtReportEnableread-writecurrentEnable or disable Alarm Report
1.3.6.1.4.1.8886.1.34.1.7.1.4ColumnraisecomAlarmMgmtMonitorEnableread-writecurrentEnable or disable alarm monitor
1.3.6.1.4.1.8886.1.34.1.7.1.5ColumnraisecomAlarmMgmtInverseModeread-writecurrentThe mode of alarm inverse
1.3.6.1.4.1.8886.1.34.1.7.1.6ColumnraisecomAlarmMgmtModuleNameread-onlycurrentThe module name which this alarm belongs to.
1.3.6.1.4.1.8886.1.34.1.7.1.7ColumnraisecomAlarmMgmtGroupNameread-onlycurrentThe name of alarm group.
1.3.6.1.4.1.8886.1.34.1.8ScalarraisecomAlarmMgmtRepeatIndexread-writecurrentAlarm will be repeated according to this alarm index.
Type Definitions
NameSyntaxStatusDescription
AlarmInverseModeINTEGER { none(1), auto(2), manual(3) }currentDescribes the mode of alarm inverse
AlarmStorageModeINTEGER { stop(1), loop(2) }currentDescribes how to store alarm active table when the alarm table was full.When the storage mode is stop,the new raised alarm will be discarded.It will not insert to alarm active table. If the storage mode is loop,the olde…