MIB Viewer

RBN-OPTICAL-TRANSCEIVER-MIB

53 objects
The MIB used to manage the Optical Transceivers in Line Card ports in SSR
OIDNameAccessStatusDescription
1.3.6.1.4.1.2352.2.49.0.2NotificationrbnOpticalTransceiverAlarmcurrentAn rbnOpticalTransceiverAlarm notification signifies that an alarm has been raised or cleared on a Optical Transceiver
1.3.6.1.4.1.2352.2.49.0.3NotificationrbnOpticalTransceiverLaneAlarmcurrentAn rbnOpticalTransceiverLaneAlarm notification signifies that an alarm has been raised or cleared in a lane on a Optical Transceiver
1.3.6.1.4.1.2352.2.49.2.3NoderbnOpticalTransceiverMonMIBGroups
1.3.6.1.4.1.2352.2.49.2.3.2GrouprbnOpticalTransceiverMonMIBNotificationGroupcurrentA collection of notifications providing Optical Transceiver fault condition
1.3.6.1.4.1.2352.2.49.2.4NoderbnOpticalTransceiverMonMIBCompliances
1.3.6.1.4.1.2352.2.49.2.4.1CompliancerbnOpticalTransceiverMonMIBCompliancecurrentThe compliance statement for the OpticalTransceiver MIB
1.3.6.1.4.1.2352.2.50IdentityrbnOpticalTransceiverThe MIB used to manage the Optical Transceivers in Line Card ports in SSR
1.3.6.1.4.1.2352.2.50.1NoderbnOpticalTransceiverDetails
1.3.6.1.4.1.2352.2.50.1.1TablerbnOpticalTransceiverPortTablenot-accessiblecurrentThis table contains the ports with optical transceivers and corresponding parameters
1.3.6.1.4.1.2352.2.50.1.1.1RowrbnOpticalTransceiverPortEntrynot-accessiblecurrentLine Card port optical transceiver parameter description.
1.3.6.1.4.1.2352.2.50.1.1.1.1ColumnrbnOpticalTransceiverCardSlotread-onlycurrentThe chassis slot number in which the card is present where the Optical Transceiver plugged in.
1.3.6.1.4.1.2352.2.50.1.1.1.2ColumnrbnOpticalTransceiverPortread-onlycurrentThe port number where the Optical Transceiver plugged in.
1.3.6.1.4.1.2352.2.50.1.1.1.3ColumnrbnOpticalTransceiverTyperead-onlycurrentType and category of Optical Transceiver
1.3.6.1.4.1.2352.2.50.1.1.1.4ColumnrbnOpticalTransceiverMediaTyperead-onlycurrentOptical Transceiver Media Type
1.3.6.1.4.1.2352.2.50.1.1.1.5ColumnrbnOpticalTransceiverRbnEricssonApprovedread-onlycurrentIs the Optical Transceiver n this port approved by Ericsson, Yes/No?
1.3.6.1.4.1.2352.2.50.1.1.1.6ColumnrbnOpticalTransceiverDiagMonitoringread-onlycurrentIs Optical Transceiver Diag Monitoring On or Off?
1.3.6.1.4.1.2352.2.50.1.1.1.7ColumnrbnOpticalTransceiverCLEIcoderead-onlycurrentOptical Transceiver Common Language Equipment Identifier (CLEI) code.
1.3.6.1.4.1.2352.2.50.1.1.1.8ColumnrbnOpticalTransceiverSerialNoread-onlycurrentOptical Transceiver serial number
1.3.6.1.4.1.2352.2.50.1.1.1.9ColumnrbnOpticalTransceiverFrequencyread-onlycurrentOptical Transceiver Frequency
1.3.6.1.4.1.2352.2.50.1.1.1.10ColumnrbnOpticalTransceiverWaveLengthread-onlycurrentOptical Transceiver Wave Length
1.3.6.1.4.1.2352.2.50.1.1.1.11ColumnrbnOpticalTransceiverAdditionalFeaturesread-onlycurrentOptical Transceiver Additional Features such as, Is Optical Transceiver OTN capable? and/or Is Optical Transceiver Tunable?
1.3.6.1.4.1.2352.2.50.1.1.1.12ColumnrbnOpticalTransceiverFrequencyStartread-onlycurrentFrequency Start for tunable optical transceiver. Not applicable if optical transceiver is not tunable
1.3.6.1.4.1.2352.2.50.1.1.1.13ColumnrbnOpticalTransceiverFrequencyEndread-onlycurrentFrequency End for tunable optical transceiver. Not applicable if optical transceiver is not tunable
1.3.6.1.4.1.2352.2.50.1.1.1.14ColumnrbnOpticalTransceiverFrequencySpacingread-onlycurrentFrequency Spacing for tunable optical transceiver. Not applicable if optical transceiver is not tunable
1.3.6.1.4.1.2352.2.50.1.1.1.15ColumnrbnOpticalTransceiverOTNFramerread-onlycurrentFramer of OTN if optical transceiver is OTN capable. Not applicable if optical transceiver is not OTN capable
1.3.6.1.4.1.2352.2.50.1.1.1.16ColumnrbnOpticalTransceiverOTNFECread-onlycurrentFEC of OTN if optical transceiver is OTN capable. Not applicable if optical transceiver is not OTN capable
1.3.6.1.4.1.2352.2.50.1.1.1.17ColumnrbnOpticalTransceiverPowerLevelread-onlycurrentOptical Transceiver Power Level
1.3.6.1.4.1.2352.2.50.1.1.1.18ColumnrbnOpticalTransceiverActiveAlarmCountread-onlycurrentNumber of alarms active on the Optical Transceiver
1.3.6.1.4.1.2352.2.50.1.1.1.19ColumnrbnOpticalTransceiverParamBitMaskread-onlycurrentThis Bit Mask indicates which values are valid for RbnOpticalTransceiverParamType in rbnOpticalTransceiverParamTable: 0x0001 optical transceiver txpower valid …
1.3.6.1.4.1.2352.2.50.1.1.1.20ColumnrbnOpticalTransceiverLaneCountread-onlycurrentNumber of Lanes in optical transceiver
1.3.6.1.4.1.2352.2.50.1.2TablerbnOpticalTransceiverParamTablenot-accessiblecurrentThis table provides objects to monitor optical transceiver parameters in a network element. It also provides objects for monitoring high and low warning and al…
1.3.6.1.4.1.2352.2.50.1.2.1RowrbnOpticalTransceiverParamEntrynot-accessiblecurrentOpticalTransceiver Parameter Entries in Table
1.3.6.1.4.1.2352.2.50.1.2.1.1ColumnrbnOpticalTransceiverParamTyperead-onlycurrentThis object specifies the optical parameter type that is being monitored in this entry.
1.3.6.1.4.1.2352.2.50.1.2.1.2ColumnrbnOpticalTransceiverParamDescriptionread-onlycurrentThis object specifies the optical parameter description including units that is being monitored in this entry.
1.3.6.1.4.1.2352.2.50.1.2.1.3ColumnrbnOpticalTransceiverCurrentValueread-onlycurrentThe current value of tx power, rx power, temperature, bias current and Vcc
1.3.6.1.4.1.2352.2.50.1.2.1.4ColumnrbnOpticalTransceiverMaxAlarmValueread-onlycurrentThe alarm high threshold value of tx power, rx power, temperature, bias current and Vcc
1.3.6.1.4.1.2352.2.50.1.2.1.5ColumnrbnOpticalTransceiverMaxWarningValueread-onlycurrentThe warning high threshold value of tx power, rx power, temperature, bias current and Vcc
1.3.6.1.4.1.2352.2.50.1.2.1.6ColumnrbnOpticalTransceiverMinAlarmValueread-onlycurrentThe alarm low threshold value of tx power, rx power, temperature, bias current and Vcc
1.3.6.1.4.1.2352.2.50.1.2.1.7ColumnrbnOpticalTransceiverMinWarningValueread-onlycurrentThe warning low threshold value of tx power, rx power, temperature, bias current and Vcc
1.3.6.1.4.1.2352.2.50.1.3TablerbnLaneInOpticalTransceiverParamTablenot-accessiblecurrentThis table provides objects to monitor optical transceiver parameters in a network element. It also provides objects for monitoring high and low warning and al…
1.3.6.1.4.1.2352.2.50.1.3.1RowrbnLaneInOpticalTransceiverParamEntrynot-accessiblecurrentLaneInOpticalTransceiver Parameter Entries in Table
1.3.6.1.4.1.2352.2.50.1.3.1.1ColumnrbnLaneInOpticalTransceiverread-onlycurrentThis object specifies the optical transceiver lane that is being monitored in this entry.
1.3.6.1.4.1.2352.2.50.1.3.1.2ColumnrbnLaneInOpticalTransceiverParamTyperead-onlycurrentThis object specifies the optical parameter type that is being monitored in this entry.
1.3.6.1.4.1.2352.2.50.1.3.1.3ColumnrbnLaneInOpticalTransceiverCurrentValueread-onlycurrentThe current value of tx power, rx power, temperature, bias current and Vcc
1.3.6.1.4.1.2352.2.50.1.3.1.4ColumnrbnLaneInOpticalTransceiverMaxAlarmValueread-onlycurrentThe alarm high threshold value of tx power, rx power, temperature, bias current and Vcc
1.3.6.1.4.1.2352.2.50.1.3.1.5ColumnrbnLaneInOpticalTransceiverMaxWarningValueread-onlycurrentThe warning high threshold value of tx power, rx power, temperature, bias current and Vcc
1.3.6.1.4.1.2352.2.50.1.3.1.6ColumnrbnLaneInOpticalTransceiverMinAlarmValueread-onlycurrentThe alarm low threshold value of tx power, rx power, temperature, bias current and Vcc
1.3.6.1.4.1.2352.2.50.1.3.1.7ColumnrbnLaneInOpticalTransceiverMinWarningValueread-onlycurrentThe warning low threshold value of tx power, rx power, temperature, bias current and Vcc
Type Definitions
NameSyntaxStatusDescription
RbnLaneInOpticalTransceiverParameterValueInteger32 (-1000000..1000000 )currentTx power range - unit milli dbm Rx power range - unit milli dbm temperature range - Represents a temperature, in degrees Celsius (0..(100.000)) Bias Current Range - unit 100s of microamperes
RbnLaneInOpticalTransceiverParamTypeINTEGER { laneTxPower(1), laneRxPower(2), laneTemperature(3), laneLaserBiasCurrent(4) }currentEnums for optical transceiver parameters laneTxPower (1) : transmitter power laneRxPower (2) : receiver power laneTemperature (3) : Temperature laneLaserBiasCurrent (4) : Laser bias current in 100s of microamperes
RbnOpticalTransceiverParameterValueInteger32 (-1000000..1000000 )currentTx power value or threshold value - unit milli dbm Rx power value or threshold value - unit milli dbm temperature value or threshold value - Represents a temperature, in degrees Celsius (0..(100.000)) Bias Current value…
RbnOpticalTransceiverParamTypeINTEGER { txpower(1), rxpower(2), temperature(3), laserBiasCurrent(4), soaBiasCurrent(5), vcc(6), aux1 (7), aux2 (8) }currentEnums for optical transceiver parameters txpower (1) : transmitter power rxpower (2) : receiver power temperature (3) : Temperature laserBiasCurrent (4) : Laser bias current in 100s of microamperes soaBiasCurrent (5) : …
RbnOpticalTransceiverParamWaveLengthInteger32 (-1000000..1000000 )currentWave Length in NM in 1/100th