RC7586-MIB
113 objects
The Structure of Management Information for the Codan enterprise. Copyright(c) 2009 All rights reserved
Imported Objects
| CODAN-SMI | satcomMibs |
| SNMPv2-SMI | Counter32 Gauge32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE TimeTicks |
| SNMPv2-TC | DateAndTime DisplayString TestAndIncr TEXTUAL-CONVENTION TimeInterval TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.23304.2.2 | Identityrc7586MIB | The Structure of Management Information for the Codan enterprise. Copyright(c) 2009 All rights reserved | ||
| 1.3.6.1.4.1.23304.2.2.1 | Nodebuc1 | |||
| 1.3.6.1.4.1.23304.2.2.1.1 | Nodebuc1Configuration | |||
| 1.3.6.1.4.1.23304.2.2.1.1.1 | Nodebuc1TxSettings | |||
| 1.3.6.1.4.1.23304.2.2.1.1.1.1 | Scalarbuc1TxOn | read-write | current | Sets Tx on/off. Respond -1 if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.1.1.2 | Scalarbuc1TxDefault | read-write | current | Sets Tx default 1-last 0-off. Respond -1 if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.1.1.3 | Scalarbuc1TxAttenuator | read-write | current | Sets/Gets Tx attenuation value in 1dBm steps. Respond -1 if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.1.2 | Nodebuc1PktProtocol | |||
| 1.3.6.1.4.1.23304.2.2.1.1.2.1 | Scalarbuc1Protocol | read-write | current | Sets/Gets packet protocol 0 - ASCII, 1 - CODAN, 2 - SAbus, 3 - Comstream, 4 - NDSatcom. Respond -1 if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.1.2.2 | Scalarbuc1Address | read-write | current | Sets/Gets packet address: 0-31 NDSatcom ...Respond -1 if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.1.3 | Nodebuc1RCSetting | |||
| 1.3.6.1.4.1.23304.2.2.1.1.3.1 | Scalarbuc1Mode | read-write | current | Sets/Gets redundancy mode 0-none, 1-warm, 2-hot. Respond -1 if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.1.3.2 | Scalarbuc1OnLine | read-write | current | Sets/Gets redundancy mode on on/off line state. Respond -1 if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.1.4 | Nodebuc1Freqs | |||
| 1.3.6.1.4.1.23304.2.2.1.1.4.1 | Scalarbuc1RFFreq | read-write | current | Sets/Gets the RBUC RF frequency. Respond -1 if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.1.4.2 | Scalarbuc1IFFreq | read-write | current | Sets/Gets the RBUC IF frequency. Respond -1 if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.1.4.3 | Scalarbuc1LOFreq | read-write | current | Sets/Gets the RBUC LO frequency. Respond -1 if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.1.5 | Nodebuc1Misc | |||
| 1.3.6.1.4.1.23304.2.2.1.1.5.1 | Scalarbuc1SerIf | read-write | current | Sets/Gets serial interface - rate, length, parity, stop, terminate RS422/485. **** No respond - message if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.1.5.2 | Scalarbuc1PwrAlarmThresh | read-write | current | Sets/Gets power alarm threshold. **** No respond - message if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.1.5.3 | Scalarbuc1BurstPwrThresh | read-write | current | Sets/Gets burst power threshold. **** No respond - message if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.1.5.4 | Scalarbuc1RefSource | read-write | current | Sets/Gets reference source 0-external, 1-internal (Only for RBUC). **** No respond - message if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.1.5.5 | Scalarbuc1LEDState | read-write | current | Sets/Gets LEDs status on/off (Only for RBUC). **** No respond - message if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.2 | Nodebuc1Status | |||
| 1.3.6.1.4.1.23304.2.2.1.2.1 | Scalarbuc1PaStatus | read-only | current | Gets to 1 when PA is on. Respond -1 if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.2.2 | Scalarbuc1TxPower | read-only | current | Gets Tx power format x.x dB. **** No respond - message if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.2.3 | Scalarbuc1TxBurstPower | read-only | current | Gets Tx power. Format is x.x,y.y,z.z, where x.x is current burst power, y.y is min and z.z is max burts power. **** No respond - message if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.2.4 | Scalarbuc1Faults | read-only | current | Gets the current fault status. Format - Bit0 PA fault, Bit1 Fan fault, Bit2 Power fault, Bit3 Temp fault, Bit4 10MHz fault, Bit5 Internal fault Bit6 LNB fault,… |
| 1.3.6.1.4.1.23304.2.2.1.2.5 | Scalarbuc1LatchedFaults | read-only | current | Gets the current latched faults. Format is same as Faults. Respond -1 if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.2.6 | Scalarbuc1Temperature | read-only | current | Gets the BUC temperature. Format is x.x. **** No respond - message if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.2.7 | Scalarbuc1MinMaxTemperature | read-only | current | Gets the BUC temperature. Format is x.x,y.y where x.x is max and y.y is min temperature. **** No respond - message if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.2.8 | Scalarbuc1SystemSetting | read-only | current | Gets the current system status. Format is Bit0 - PA state, Bit1 - RS232 Tx, Bit2 - FSK Tx, Bit3 - RS485 Tx Bit4 - Redundancy mode, Bit5 - Online, Bit6..Bit7 - … |
| 1.3.6.1.4.1.23304.2.2.1.2.9 | Scalarbuc1SystemPoll | read-only | current | Gets the system poll status. Format is Bit0 - Fault, Bit1 - System change. Respond -1 if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.2.10 | Scalarbuc1DeviceType | read-only | current | Gets the device type. Format is X,Y where X is the model and Y is software version. **** No respond - message if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.2.11 | Scalarbuc1Gateway | read-only | current | Gets the BUC gateway address (Only for RBUC). **** No respond - message if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.2.12 | Scalarbuc1IpAddress | read-only | current | Gets the BUC IP address (Only for RBUC). **** No respond - message if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.2.13 | Scalarbuc1MACAddress | read-only | current | Gets the BUC MAC address (Only for RBUC). **** No respond - message if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.2.14 | Scalarbuc1Netmask | read-only | current | Gets the BUC netmask (Only for RBUC). **** No respond - message if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.2.15 | Scalarbuc1RefPower | read-only | current | Gets the BUC reference power. **** No respond - message if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.2.16 | Scalarbuc1Config | read-only | current | Gets the BUC configuration. **** No respond - message if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.2.17 | Scalarbuc1BuildStandard | read-only | current | Gets the BUC build standard. **** No respond - message if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.1.3 | Nodebuc1Info | |||
| 1.3.6.1.4.1.23304.2.2.1.3.1 | Scalarbuc1IdInfo | read-only | current | Gets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown. **** No respond - message if buc1 n… |
| 1.3.6.1.4.1.23304.2.2.1.3.2 | Scalarbuc1Limits | read-only | current | Gets the limit data for the BUC. Format is: Power meter MIN/MAX , IF,RF and LO frequencies. This string will have a zero length if the revision is unknown. ***… |
| 1.3.6.1.4.1.23304.2.2.1.3.3 | Scalarbuc1PktProtocolsInfo | read-only | current | Gets supported packet protocols and the corresponding address ranges. **** No respond - message if buc1 not connected. |
| 1.3.6.1.4.1.23304.2.2.2 | Nodebuc2 | |||
| 1.3.6.1.4.1.23304.2.2.2.1 | Nodebuc2Configuration | |||
| 1.3.6.1.4.1.23304.2.2.2.1.1 | Nodebuc2TxSettings | |||
| 1.3.6.1.4.1.23304.2.2.2.1.1.1 | Scalarbuc2TxOn | read-write | current | Sets Tx on/off. Respond -1 if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.1.1.2 | Scalarbuc2TxDefault | read-write | current | Sets Tx default 1-last 0-off. Respond -1 if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.1.1.3 | Scalarbuc2TxAttenuator | read-write | current | Sets/Gets Tx attenuation value in 1dBm steps. Respond -1 if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.1.2 | Nodebuc2PktProtocol | |||
| 1.3.6.1.4.1.23304.2.2.2.1.2.1 | Scalarbuc2Protocol | read-write | current | Sets/Gets packet protocol 0 - ASCII, 1 - CODAN, 2 - SAbus, 3 - Comstream, 4 - NDSatcom. Respond -1 if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.1.2.2 | Scalarbuc2Address | read-write | current | Sets/Gets packet address: 0-31 NDSatcom ...Respond -1 if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.1.3 | Nodebuc2RCSetting | |||
| 1.3.6.1.4.1.23304.2.2.2.1.3.1 | Scalarbuc2Mode | read-write | current | Sets/Gets redundancy mode 0-none, 1-warm, 2-hot. Respond -1 if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.1.3.2 | Scalarbuc2OnLine | read-write | current | Sets/Gets redundancy mode on on/off line state. Respond -1 if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.1.4 | Nodebuc2Freqs | |||
| 1.3.6.1.4.1.23304.2.2.2.1.4.1 | Scalarbuc2RFFreq | read-write | current | Sets/Gets the RBUC RF frequency. Respond -1 if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.1.4.2 | Scalarbuc2IFFreq | read-write | current | Sets/Gets the RBUC IF frequency. Respond -1 if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.1.4.3 | Scalarbuc2LOFreq | read-write | current | Sets/Gets the RBUC LO frequency. Respond -1 if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.1.5 | Nodebuc2Misc | |||
| 1.3.6.1.4.1.23304.2.2.2.1.5.1 | Scalarbuc2SerIf | read-write | current | Sets/Gets serial interface - rate, length, parity, stop, terminate RS422/485. **** No respond - message if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.1.5.2 | Scalarbuc2PwrAlarmThresh | read-write | current | Sets/Gets power alarm threshold. **** No respond - message if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.1.5.3 | Scalarbuc2BurstPwrThresh | read-write | current | Sets/Gets burst power threshold. **** No respond - message if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.1.5.4 | Scalarbuc2RefSource | read-write | current | Sets/Gets reference source 0-external, 1-internal (Only for RBUC). **** No respond - message if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.1.5.5 | Scalarbuc2LEDState | read-write | current | Sets/Gets LEDs status on/off (Only for RBUC). **** No respond - message if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.2 | Nodebuc2Status | |||
| 1.3.6.1.4.1.23304.2.2.2.2.1 | Scalarbuc2PaStatus | read-only | current | Gets to 1 when PA is on. Respond -1 if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.2.2 | Scalarbuc2TxPower | read-only | current | Gets Tx power format x.x dB. **** No respond - message if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.2.3 | Scalarbuc2TxBurstPower | read-only | current | Gets Tx power. Format is x.x,y.y,z.z, where x.x is current burst power, y.y is min and z.z is max burts power. **** No respond - message if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.2.4 | Scalarbuc2Faults | read-only | current | Gets the current fault status. Format - Bit0 PA fault, Bit1 Fan fault, Bit2 Power fault, Bit3 Temp fault, Bit4 10MHz fault, Bit5 Internal fault Bit6 LNB fault,… |
| 1.3.6.1.4.1.23304.2.2.2.2.5 | Scalarbuc2LatchedFaults | read-only | current | Gets the current latched faults. Format is same as Faults. Respond -1 if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.2.6 | Scalarbuc2Temperature | read-only | current | Gets the BUC temperature. Format is x.x. **** No respond - message if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.2.7 | Scalarbuc2MinMaxTemperature | read-only | current | Gets the BUC temperature. Format is x.x,y.y where x.x is max and y.y is min temperature. **** No respond - message if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.2.8 | Scalarbuc2SystemSetting | read-only | current | Gets the current system status. Format is Bit0 - PA state, Bit1 - RS232 Tx, Bit2 - FSK Tx, Bit3 - RS485 Tx Bit4 - Redundancy mode, Bit5 - Online, Bit6..Bit7 - … |
| 1.3.6.1.4.1.23304.2.2.2.2.9 | Scalarbuc2SystemPoll | read-only | current | Gets the system poll status. Format is Bit0 - Fault, Bit1 - System change. Respond -1 if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.2.10 | Scalarbuc2DeviceType | read-only | current | Gets the device type. Format is X,Y where X is the model and Y is software version. **** No respond - message if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.2.11 | Scalarbuc2Gateway | read-only | current | Gets the BUC gateway address (Only for RBUC). **** No respond - message if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.2.12 | Scalarbuc2IpAddress | read-only | current | Gets the BUC IP address (Only for RBUC). **** No respond - message if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.2.13 | Scalarbuc2MACAddress | read-only | current | Gets the BUC MAC address (Only for RBUC). **** No respond - message if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.2.14 | Scalarbuc2Netmask | read-only | current | Gets the BUC netmask (Only for RBUC). **** No respond - message if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.2.15 | Scalarbuc2RefPower | read-only | current | Gets the BUC reference power. **** No respond - message if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.2.16 | Scalarbuc2Config | read-only | current | Gets the BUC configuration. **** No respond - message if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.2.17 | Scalarbuc2BuildStandard | read-only | current | Gets the BUC build standard. **** No respond - message if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.2.3 | Nodebuc2Info | |||
| 1.3.6.1.4.1.23304.2.2.2.3.1 | Scalarbuc2IdInfo | read-only | current | Gets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown. **** No respond - message if buc2 n… |
| 1.3.6.1.4.1.23304.2.2.2.3.2 | Scalarbuc2Limits | read-only | current | Gets the limit data for the BUC. Format is: Power meter MIN/MAX , IF,RF and LO frequencies. This string will have a zero length if the revision is unknown. ***… |
| 1.3.6.1.4.1.23304.2.2.2.3.3 | Scalarbuc2PktProtocolsInfo | read-only | current | Gets supported packet protocols and the corresponding address ranges. **** No respond - message if buc2 not connected. |
| 1.3.6.1.4.1.23304.2.2.3 | Nodectrl | |||
| 1.3.6.1.4.1.23304.2.2.3.1 | Nodesettings | |||
| 1.3.6.1.4.1.23304.2.2.3.1.1 | ScalaroperationalMode | read-write | current | Sets 7586 operational mode - Auto, Manual Stream1, Stream2. |
| 1.3.6.1.4.1.23304.2.2.3.1.2 | ScalaronlineStream | read-write | current | Sets the online stream. |
| 1.3.6.1.4.1.23304.2.2.3.1.3 | ScalarwaveguideSwitch | read-write | current | Sets Waveguide switch Rx+Tx, Rx/Tx and Tx Only. |
| 1.3.6.1.4.1.23304.2.2.3.1.4 | ScalarstartupTime | read-write | current | Sets Startup time. |
| 1.3.6.1.4.1.23304.2.2.3.1.5 | ScalarlnbCurrentLimit | read-write | current | Sets LNB current limits. |
| 1.3.6.1.4.1.23304.2.2.3.1.6 | ScalarledState | read-write | current | Sets 7586 LED. |
| 1.3.6.1.4.1.23304.2.2.3.1.7 | ScalarrefSource | read-write | current | Sets 7586 reference state. |
| 1.3.6.1.4.1.23304.2.2.3.1.8 | ScalarrefTrim | read-write | current | Sets 7586 reference trim. |
| 1.3.6.1.4.1.23304.2.2.3.1.9 | ScalarrefThresh | read-write | current | Sets 7586 reference alarm treshold. |
| 1.3.6.1.4.1.23304.2.2.3.1.10 | ScalarrefPwr | read-only | current | Gets 7586 reference power. |
| 1.3.6.1.4.1.23304.2.2.3.1.11 | ScalaripAddr | read-only | current | Gets the 7586 IP address. |
| 1.3.6.1.4.1.23304.2.2.3.1.12 | ScalarmacAddress | read-only | current | Gets the 7586 MAC address. |
| 1.3.6.1.4.1.23304.2.2.3.1.13 | Scalarnetmask | read-only | current | Gets the 7586 netmask. |
| 1.3.6.1.4.1.23304.2.2.3.1.14 | Scalargateway | read-only | current | Gets the 7586 gateway address. |
| 1.3.6.1.4.1.23304.2.2.3.2 | Nodestatus | |||
| 1.3.6.1.4.1.23304.2.2.3.2.1 | ScalarlnbCurrent | read-only | current | Sets 7586 LNB current. |
| 1.3.6.1.4.1.23304.2.2.3.2.2 | ScalarlnbVoltage | read-only | current | Sets 7586 LNB voltage. |
| 1.3.6.1.4.1.23304.2.2.3.2.3 | Scalarfaults | read-only | current | Gets the current fault status. |
| 1.3.6.1.4.1.23304.2.2.3.3 | Nodeinfo | |||
| 1.3.6.1.4.1.23304.2.2.3.3.1 | ScalaridInfo | read-only | current | Gets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| ComponentRevision | DisplayString(SIZE(2)) | current | The hex value in the first octet - xx - represents the major revision no. and the hex value in the second octet - yy - represents the minor revision no. |
| FaultStatus7586 | BITS { dc1fault(0), dc2fault(1), buc1fault(2), buc2fault(3), lnb1fault(4), lnb2fault(5), txswfault(6), rxswfault(7), internalfault(8), ref10mhzfault(9) } | current | Describes all the possible faults in the system as a bit pattern. |