MIB Viewer

RFC1232-MIB

50 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.3.2Nodeds1
1.3.6.1.3.2.1Tableds1ConfigTablenot-accessiblemandatoryThe DS1 Configuration table.
1.3.6.1.3.2.1.1Rowds1ConfigEntrynot-accessiblemandatoryAn entry in the DS1 Configuration table.
1.3.6.1.3.2.1.1.1Columnds1CSUIndexread-onlymandatoryThe index value which uniquely identifies the CSU to which this entry is applicable.
1.3.6.1.3.2.1.1.2Columnds1Indexread-onlymandatoryAn index value that uniquely identifies an interface to a ds1. The interface identified by a particular value of this index is the same interface as identified…
1.3.6.1.3.2.1.1.3Columnds1TimeElapsedread-onlymandatoryThe number of seconds that have elapsed since the beginning of the current error-measurement period. Any fraction is rounded up.
1.3.6.1.3.2.1.1.4Columnds1ValidIntervalsread-onlymandatoryThe number of previous intervals for which valid data was collected. The value will be 96 unless the CSU device was brought online within the last 24 hours, in…
1.3.6.1.3.2.1.1.5Columnds1LineTyperead-onlymandatoryThis variable indicates the variety of DS1 Line implementing this circuit. The type of circuit affects the number of bits per second that the circuit can reaso…
1.3.6.1.3.2.1.1.6Columnds1ZeroCodingread-onlymandatoryThis variable describes the variety of Zero Code Suppression used on the link, which in turn affects a number of its characteristics. ds1JammedBit refers the J…
1.3.6.1.3.2.1.1.7Columnds1Loopbackread-onlymandatoryThis variable represents the loopback state of the CSU. Devices supporting read/write access should return badValue in response to a requested loopback state t…
1.3.6.1.3.2.1.1.8Columnds1SendCoderead-onlymandatoryThis variable indicates what type of code is being sent across the DS1 circuit by the CSU. The values mean: ds1SendNoCode sending looped or normal data ds1Send…
1.3.6.1.3.2.1.1.9Columnds1YellowAlarmread-onlymandatoryThis variable indicates if a Yellow Alarm condition exists. Note that G.704 interfaces do not support Yellow Alarms. Accordingly, such agents should return the…
1.3.6.1.3.2.1.1.10Columnds1RedAlarmread-onlymandatoryThis variable indicates if a Red Alarm condition exists. Note that G.704 interfaces do not support Red Alarms. Accordingly, such agents should return the value…
1.3.6.1.3.2.1.1.11Columnds1CircuitIdentifierread-onlymandatoryThis variable contains the transmission vendor's circuit identifier, for the purpose of facilitating troubleshooting.
1.3.6.1.3.2.2Tableds1IntervalTablenot-accessiblemandatoryThe DS1 Interval table.
1.3.6.1.3.2.2.1Rowds1IntervalEntrynot-accessiblemandatoryAn entry in the DS1 Interval table.
1.3.6.1.3.2.2.1.1Columnds1IntervalIndexread-onlymandatoryThe index value which uniquely identifies the CSU to which this entry is applicable. The interface identified by a particular value of this index is the same i…
1.3.6.1.3.2.2.1.2Columnds1IntervalNumberread-onlymandatoryA number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minute interval (assuming that a…
1.3.6.1.3.2.2.1.3Columnds1IntervalESsread-onlymandatoryThe counter associated with the number of Errored Seconds, as defined by ANSI Draft Standard T1M1.3/90 - 027R2[15], encountered by a DS1 CSU during one of the …
1.3.6.1.3.2.2.1.4Columnds1IntervalSESsread-onlymandatoryThe counter associated with the number of Severely Errored Seconds, as defined by ANSI Draft Standard T1M1.3/90 - 027R2[15], encountered by a DS1 CSU during on…
1.3.6.1.3.2.2.1.5Columnds1IntervalSEFSsread-onlymandatoryThe counter associated with the number of Severely Errored Framing Seconds, as defined by ANSI Draft Standard T1M1.3/90 - 027R2[15], encountered by a DS1 CSU d…
1.3.6.1.3.2.2.1.6Columnds1IntervalUASsread-onlymandatoryThe counter associated with the number of Unavailable Seconds, as defined by ANSI Draft Standard T1M1.3/90 - 027R2[15], encountered by a DS1 CSU during one of …
1.3.6.1.3.2.2.1.7Columnds1IntervalCSSsread-onlymandatoryThe counter associated with the number of Controlled Slip Seconds, as defined by ANSI Draft Standard T1M1.3/90 - 027R2[15], encountered by a DS1 CSU during one…
1.3.6.1.3.2.2.1.8Columnds1IntervalBPVsread-onlymandatoryThe counter associated with the number of Bipolar Violations, as defined by ANSI Draft Standard T1M1.3/90 - 027R2[15], encountered by a DS1 CSU during one of t…
1.3.6.1.3.2.2.1.9Columnds1IntervalCVsread-onlymandatoryThe counter associated with the number of Code Violation Error Events, as defined by ANSI Draft Standard T1M1.3/90 - 027R2[15], encountered by a DS1 CSU during…
1.3.6.1.3.2.3Tableds1CurrentTablenot-accessiblemandatoryThe DS1 Current table.
1.3.6.1.3.2.3.1Rowds1CurrentEntrynot-accessiblemandatoryAn entry in the DS1 Current table.
1.3.6.1.3.2.3.1.1Columnds1CurrentIndexread-onlymandatoryThe index value which uniquely identifies the CSU to which this entry is applicable. The interface identified by a particular value of this index is the same i…
1.3.6.1.3.2.3.1.2Columnds1CurrentESsread-onlymandatoryThe counter associated with the number of Errored Seconds, as defined by ANSI Draft Standard T1M1.3/90 - 027R2[15], encountered by a DS1 CSU in the current 15 …
1.3.6.1.3.2.3.1.3Columnds1CurrentSESsread-onlymandatoryThe counter associated with the number of Severely Errored Seconds, as defined by ANSI Draft Standard T1M1.3/90 - 027R2[15], encountered by a DS1 CSU in the cu…
1.3.6.1.3.2.3.1.4Columnds1CurrentSEFSsread-onlymandatoryThe counter associated with the number of Severely Errored Framing Seconds, as defined by ANSI Draft Standard T1M1.3/90 - 027R2[15], encountered by a DS1 CSU i…
1.3.6.1.3.2.3.1.5Columnds1CurrentUASsread-onlymandatoryThe counter associated with the number of Unavailable Seconds, as defined by ANSI Draft Standard T1M1.3/90 - 027R2[15], encountered by a DS1 CSU in the current…
1.3.6.1.3.2.3.1.6Columnds1CurrentCSSsread-onlymandatoryThe counter associated with the number of Controlled Slip Seconds, as defined by ANSI Draft Standard T1M1.3/90 - 027R2[15], encountered by a DS1 CSU in the cur…
1.3.6.1.3.2.3.1.7Columnds1CurrentBPVsread-onlymandatoryThe counter associated with the number of Bipolar Violations, as defined by ANSI Draft Standard T1M1.3/90 - 027R2[15], encountered by a DS1 CSU in the current …
1.3.6.1.3.2.3.1.8Columnds1CurrentCVsread-onlymandatoryThe counter associated with the number of Code Violation Error Events, as defined by ANSI Draft Standard T1M1.3/90 - 027R2[15], encountered by a DS1 CSU in the…
1.3.6.1.3.2.4Tableds1TotalTablenot-accessiblemandatoryThe DS1 Total table. 24 hour interval.
1.3.6.1.3.2.4.1Rowds1TotalEntrynot-accessiblemandatoryAn entry in the DS1 Total table.
1.3.6.1.3.2.4.1.1Columnds1TotalIndexread-onlymandatoryThe index value which uniquely identifies the CSU to which this entry is applicable. The interface identified by a particular value of this index is the same i…
1.3.6.1.3.2.4.1.2Columnds1TotalESsread-onlymandatoryThe counter associated with the number of Errored Seconds, as defined by ANSI Draft Standard T1M1.3/90 - 027R2[15], encountered by a DS1 CSU in the previous 24…
1.3.6.1.3.2.4.1.3Columnds1TotalSESsread-onlymandatoryThe counter associated with the number of Severely Errored Seconds, as defined by ANSI Draft Standard T1M1.3/90 - 027R2[15], encountered by a DS1 CSU in the pr…
1.3.6.1.3.2.4.1.4Columnds1TotalSEFSsread-onlymandatoryThe counter associated with the number of Severely Errored Framing Seconds, as defined by ANSI Draft Standard T1M1.3/90 - 027R2[15], encountered by a DS1 CSU i…
1.3.6.1.3.2.4.1.5Columnds1TotalUASsread-onlymandatoryThe counter associated with the number of Unavailable Seconds, as defined by ANSI Draft Standard T1M1.3/90 - 027R2[15], encountered by a DS1 CSU in the previou…
1.3.6.1.3.2.4.1.6Columnds1TotalCSSsread-onlymandatoryThe counter associated with the number of Controlled Slip Seconds, as defined by ANSI Draft Standard T1M1.3/90 - 027R2[15], encountered by a DS1 CSU in the pre…
1.3.6.1.3.2.4.1.7Columnds1TotalBPVsread-onlymandatoryThe counter associated with the number of Bipolar Violations, as defined by ANSI Draft Standard T1M1.3/90 - 027R2[15], encountered by a DS1 CSU in the previous…
1.3.6.1.3.2.4.1.8Columnds1TotalCVsread-onlymandatoryThe counter associated with the number of Code Violation Error Events, as defined by ANSI Draft Standard T1M1.3/90 - 027R2[15], encountered by a DS1 CSU in the…
1.3.6.1.3.2.5Tableds1FracTablenot-accessiblemandatoryThe DS1 Fractional table.
1.3.6.1.3.2.5.1Rowds1FracEntrynot-accessiblemandatoryAn entry in the DS1 Fractional table.
1.3.6.1.3.2.5.1.1Columnds1FracIndexread-onlymandatoryThe index value which uniquely identifies the CSU to which this entry is applicable. The interface identified by a particular value of this index is the same i…
1.3.6.1.3.2.5.1.2Columnds1FracNumberread-onlymandatoryThe channel number for this entry.
1.3.6.1.3.2.5.1.3Columnds1FracIfIndexread-onlymandatoryAn index value that uniquely identifies an interface to a ds1. The interface identified by a particular value of this index is the same interface as identified…