RFC1407-EXT-MIB
25 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.930.3.6 | Nodecnds3e3Ext | |||
| 1.3.6.1.4.1.930.3.6.1 | Nodecndsx3Oper | |||
| 1.3.6.1.4.1.930.3.6.1.1 | Tablecndsx3OperTable | not-accessible | mandatory | This table contains the configuration information that are operational currently. This table contains all the objects defined in dsx3ConfigTable plus some addi… |
| 1.3.6.1.4.1.930.3.6.1.1.1 | Rowcndsx3OperEntry | not-accessible | mandatory | An entry in the DS3/E3 Operational Configuration table. |
| 1.3.6.1.4.1.930.3.6.1.1.1.1 | Columncndsx3OperLineIndex | read-only | mandatory | This object is the identifier of a DS3/E3 Interface on a managed device. |
| 1.3.6.1.4.1.930.3.6.1.1.1.2 | Columncndsx3OperLineType | read-only | mandatory | This variable indicates the variety of DS3 C-bit or E3 application implementing this interface. The type of interface affects the interpretation of the usage a… |
| 1.3.6.1.4.1.930.3.6.1.1.1.3 | Columncndsx3OperLoopbackConfig | read-only | mandatory | This variable represents the loopback configuration of the DS3/E3 interface. dsx3NoLoop Not in the loopback state. A device that is not capable of performing a… |
| 1.3.6.1.4.1.930.3.6.1.1.1.4 | Columncndsx3OperLineStatus | read-only | mandatory | This variable indicates the Line Status of the interface. It contains loopback state information and failure state information. The dsx3LineStatus is a bit map… |
| 1.3.6.1.4.1.930.3.6.1.1.1.5 | Columncndsx3OperTransmitClockSource | read-only | mandatory | The source of Transmit Clock. is derived from the recovered receive clock of another DS3 interface. |
| 1.3.6.1.4.1.930.3.6.1.1.1.6 | Columncndsx3OperPlcpLOFEvent | read-only | mandatory | Indicates PLCP Loss of Frame event. The following value is read-only: on(1).......Loss of Frame event is present off(2)......Loss of Frame event is not present |
| 1.3.6.1.4.1.930.3.6.1.1.1.7 | Columncndsx3OperG832CellDelineation | read-only | mandatory | Indicates Cell Delineation events. The following value is read-only: on(1).......Cell Delineation event is present off(2)......Cell Delineation event is not pr… |
| 1.3.6.1.4.1.930.3.6.1.1.1.8 | Columncndsx3OperLineBuildOut | read-only | mandatory | Indicates line buildout status |
| 1.3.6.1.4.1.930.3.6.1.1.1.9 | Columncndsx3OperScramblingEnable | read-only | mandatory | This field indicates if scrambing is enabled or disabled. |
| 1.3.6.1.4.1.930.3.6.1.1.1.10 | Columncndsx3OperE3ConfigType | read-only | mandatory | This object shows E3Config mode. The following value is read-only: other(1).......other than g751 and g832 g751(2)........E3ConfigType is G751 g832(3)........E… |
| 1.3.6.1.4.1.930.3.6.2 | Nodecndsx3TotalExt | |||
| 1.3.6.1.4.1.930.3.6.2.1 | Tablecndsx3TotalExtTable | not-accessible | mandatory | This table contains the counters that are additional to the existing dsx3TotalTable |
| 1.3.6.1.4.1.930.3.6.2.1.1 | Rowcndsx3TotalExtEntry | not-accessible | mandatory | An entry in the DS3/E3 TotalExt table. |
| 1.3.6.1.4.1.930.3.6.2.1.1.1 | Columncndsx3CellPayloadHECError | read-only | mandatory | A counter of Payload HEC errors. |
| 1.3.6.1.4.1.930.3.6.3 | Nodecndsx3ConfigExt | |||
| 1.3.6.1.4.1.930.3.6.3.1 | Tablecndsx3ConfigExtTable | not-accessible | mandatory | This table contains the configurable parameters that are additional to the existing dsx3ConfigTable |
| 1.3.6.1.4.1.930.3.6.3.1.1 | Rowcndsx3ConfigExtEntry | not-accessible | mandatory | An entry in the DS3/E3 ConfigExt table. |
| 1.3.6.1.4.1.930.3.6.3.1.1.1 | Columncndsx3LineBuildOut | read-write | mandatory | Indicates LineBuild Out status |
| 1.3.6.1.4.1.930.3.6.3.1.1.2 | Columncndsx3LineIndex | read-only | mandatory | This object is the identifier of a DS3/E3 Interface on a managed device. |
| 1.3.6.1.4.1.930.3.6.3.1.1.3 | Columncndsx3ScramblingEnable | read-write | mandatory | This field indicates if scrambing is enabled or disabled. |
| 1.3.6.1.4.1.930.3.6.3.1.1.4 | Columncndsx3E3ConfigType | read-write | mandatory | This object allows to switch between E3 G751 and G832 mode. The following value is read-only: other(1).......other than g751 and g832 The following value is re… |