MIB Viewer

RS366-OPT-MIB

32 objects
No module-level DESCRIPTION found.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.449Nodecodex
1.3.6.1.4.1.449.2NodecdxProductSpecific
1.3.6.1.4.1.449.2.1Nodecdx6500
1.3.6.1.4.1.449.2.1.2Nodecdx6500Configuration
1.3.6.1.4.1.449.2.1.2.1Nodecdx6500CfgProtocolGroup
1.3.6.1.4.1.449.2.1.2.1.1Nodecdx6500PCTPortProtocolGroup
1.3.6.1.4.1.449.2.1.2.1.1.21Tablecdx6500PPCTRS366PortTablenot-accessiblemandatoryA list of RS366 Port configuration entries.
1.3.6.1.4.1.449.2.1.2.1.1.21.1Rowcdx6500PPCTRS366PortEntrynot-accessiblemandatoryAn RS366 Configuration Table entry. Each entry contains the configuration parameters for a single RS366 port.
1.3.6.1.4.1.449.2.1.2.1.1.21.1.1Columncdx6500RS366CfgPortNumberread-onlymandatoryPort Number.
1.3.6.1.4.1.449.2.1.2.1.1.21.1.2Columncdx6500RS366CfgADataPortNumberread-onlymandatoryAssociated Data Port Number
1.3.6.1.4.1.449.2.1.2.1.1.21.1.3Columncdx6500RS366CfgContXferModeread-onlymandatorymodeEon - Transfer control after end of number digit detected. modeEbt - Transfer control after maximum address digits accumulated and answerback tone is recei…
1.3.6.1.4.1.449.2.1.2.1.1.21.1.4Columncdx6500RS366CfgMaxAddrDigitsread-onlymandatoryNumber of digits required to transfer control in EBT mode. This parameter is not required in EON mode and it is set to 15 irrespective of the user entry.
1.3.6.1.4.1.449.2.1.2.1.1.21.1.5Columncdx6500RS366CfgMaxRespTimeread-onlymandatoryMaximum EIA response time in seconds before a timeout can occur. sec0 - Indicates response time out should be disabled. sec32 - Maximum EIA response time is 32…
1.3.6.1.4.1.449.2.1.2.1.1.21.1.6Columncdx6500RS366CfgElectricalInterfaceTyperead-onlymandatorySpecify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 -…
1.3.6.1.4.1.449.2.1.2.1.1.21.1.7Columncdx6500RS366CfgV24ElectricalInterfaceOptionread-onlymandatorySpecify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal
1.3.6.1.4.1.449.2.1.2.1.1.21.1.8Columncdx6500RS366CfgHighSpeedElectricalInterfaceOptionread-onlymandatorySpecify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable
1.3.6.1.4.1.449.2.1.3Nodecdx6500Statistics
1.3.6.1.4.1.449.2.1.3.1Nodecdx6500StatProtocolGroup
1.3.6.1.4.1.449.2.1.3.1.1Nodecdx6500PSTPortProtocolGroup
1.3.6.1.4.1.449.2.1.3.1.1.22Tablecdx6500PPSTRS366PortTablenot-accessiblemandatoryA list of RS366 Port statistics.
1.3.6.1.4.1.449.2.1.3.1.1.22.1Rowcdx6500PPSTRS366PortEntrynot-accessiblemandatoryAn RS366 Statistics Table entry. Each entry contains the statistics for a single RS366 port.
1.3.6.1.4.1.449.2.1.3.1.1.22.1.1Columncdx6500RS366StatPortNumberread-onlymandatoryPort Number.
1.3.6.1.4.1.449.2.1.3.1.1.22.1.2Columncdx6500RS366StatPortStatusread-onlymandatoryEnabled or Disabled.
1.3.6.1.4.1.449.2.1.3.1.1.22.1.3Columncdx6500RS366StatPortStateread-onlymandatoryPort State.
1.3.6.1.4.1.449.2.1.3.1.1.22.1.4Columncdx6500RS366StatDataNumread-onlymandatoryData Port Number.
1.3.6.1.4.1.449.2.1.3.1.1.22.1.5Columncdx6500RS366StatTotalCallsread-onlymandatoryNumber of calls made.
1.3.6.1.4.1.449.2.1.3.1.1.22.1.6Columncdx6500RS366StatFailedCallsread-onlymandatoryNumber of failed calls.
1.3.6.1.4.1.449.2.1.3.1.1.22.1.7Columncdx6500RS366StatTotalTimeoutsread-onlymandatoryNumber of protocol time-outs.
1.3.6.1.4.1.449.2.1.3.1.1.22.1.8Columncdx6500RS366StatTotalIllegalDigitsread-onlymandatoryNumber of illegal digits received.
1.3.6.1.4.1.449.2.1.3.1.1.22.1.9Columncdx6500RS366StatPortConnectedread-onlymandatoryConnected to Data Port.
1.3.6.1.4.1.449.2.1.4Nodecdx6500Controls
Type Definitions
NameSyntaxStatusDescription
DisplayStringOCTET STRING